ESBD_497643_1773864969206_02. Specifications.pdf
PDF 2 MB Posted
- Solicitation number
- 601310000099387
- Issued by
- Tarrant County, Texas
About this file
This specification document outlines detailed requirements for radar presence detector (RPD) systems and related equipment for traffic signal applications in Texas. The file contains comprehensive technical specifications, bid specifications, and installation requirements for the Wavetronix SmartSensor Matrix, SmartSensor Advance Extended Range, mounting assemblies, cables, junction boxes, and cabinet interface devices. The specifications establish equivalency standards to Wavetronix products, allowing for alternative manufacturers to bid on comparable equipment. Key products include the SmartSensor Matrix 16-beam stop bar sensor with 140-foot detection range, the SmartSensor Advance Extended Range detector with extended 900-foot detection capability for high-profile vehicles, mounting assemblies rated for 20-pound loads with two rotational axes, 6-conductor power and communication cables meeting MIL-C-26482 specifications, sensor cable junction boxes with NEMA 4X enclosure ratings, and the Click 656 cabinet interface device supporting up to six sensors with SDLC controller connectivity and Ethernet capabilities.
The specifications require all equipment to be manufactured and assembled in the United States with surface-mount assembly processes compliant with IPC-A-610C Class 2 standards. All radar presence detectors must undergo rigorous testing including 48-hour unit-level burn-in, FCC certification under CFR 47 Part 15, NEMA TS 2-2003 compliance testing, and IEC 61000-4-5 Class 4 lightning surge protection validation. Equipment must operate reliably in extreme ambient conditions ranging from -40°F to 165°F with humidity up to 95% non-condensing, and maintain performance through rain, freezing rain, snow buildup, dust, fog, and direct sunlight. Manufacturers must provide comprehensive training including classroom and field instruction, technical support with representatives available for installation and configuration, and two-year warranties against material and workmanship defects, with extended warranty options available. The installation specifications mandate proper mounting heights, cable specifications with maximum run lengths of 2,000 feet for RS-485 communications, lightning surge protection devices meeting IEC 61000-4-5 Class 4 standards, and AC-to-DC power converters rated at 48 watts with specific voltage and environmental operating parameters.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_497643_1773865066303_03. Execution of Bid.pdf | ||
| ESBD_497643_1773864942983_01. IFB 601310000099387.pdf | ||
| Bid_notify_601310000099387.txt | TXT text file | |
| ESBD_497643_1773865116419_Bid Table 601310000099387.xlsx | XLSX spreadsheet | |
| ESBD_497643_1773865094592_04. Texas Family Code Schedule.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SmartSensor Matrix
16–beam stop bar sensor The SmartSensor Matrix is a fi rst-of-its-kind stop bar presence detector designed for use at signalized intersections to detect vehicles with the reliability of radar and with all the advantages of non-intrusive detection.
˿ Matrix of 16 radars for two-dimen-sional coverage
˿ Tracks vehicles through a 90 de-gree fi eld of view that extends out 140 ft. (42.7 m)
˿ Includes Radar Vision technology to detect and track in two dimensions
˿ Reports real-time presence of both moving and stopped vehicles
˿ Standard detector-rack contact-closure interface
˿ Easy to install and operate ˿ Supports curved and angled lanes ˿ Compatible with Click 65x all-in-one cabinet interface device ˿ Automated manufacturing process
˿ Patented auto-confi guration process
˿ Patented Digital Wave Radar II technology
˿ Remote accessible for traffi c moni-toring and sensor management
˿ Flash upgradable ˿ Robust to changing temperature, light and weather conditions
78 E 1700 S, Provo, UT 84606, US � (801) 734-7200 � www.wavetronix.comWX-500-0071 1 of 13
Technical specifications Sensor outputs
| ˿ Real-time presence data across a 140-ft. (42.7-m) range |
| ˿ Maximum number of zones: 16 |
| ˿ Maximum number of channels: 16 |
| ˿ User-selectable zone to channel mapping |
| ˿ AND logic triggers the channel when all the selected zones are |
active
| ˿ OR logic used to combine multiple zones to a channel output |
| ˿ Channel output extend and delay functionality |
| ˿ Algorithms mitigate detections from wrong way or cross traffic |
| ˿ Fail-safe mode for contact closure outputs if communication is lost |
Detectable area
| ˿ Detection range: 6 to 140 ft. (1.8 to 42.7 m) |
| ˿ Field of view: 90º |
| ˿ Flexible lane configuration support including: |
| ̀ Up to 10 lanes |
| ̀ Curved lanes |
| ̀ Islands and medians |
System hardware ˿ A complete SmartSensor Matrix system includes the following hardware:
| ̀ A SmartSensor Matrix corner radar for each approach |
| ̀ Either a preassembled backplate or a cabinet interface |
device (the Click 600, 650 or 656) ̀ Contact closure input file cards (if using a preassembled backplate or Click 600): 2 or 4 channel, compatible with industry standard detector racks
Maintenance
| ˿ No cleaning or adjustment necessary |
| ˿ No battery replacement necessary |
| ˿ Recalibration is not necessary |
| ˿ Mean time between failures: 10 years (estimated based on |
manufacturing techniques)
Physical properties
| ˿ Weight: 4.2 lbs. (1.9 kg) |
| ˿ Physical dimensions: 13.2 in. × 10.6 in. × 3.3 in. (33.5 cm x 26.9 |
cm x 8.4 cm) ˿ Resistant to corrosion, fungus, moisture deterioration, and ultraviolet rays
| ˿ Enclosure: Lexan EXL polycarbonate |
| ˿ Outdoor weatherable: UL 746C |
| ˿ Watertight by NEMA 250 standard |
| ˿ NEMA 250 compliant for: |
| ̀ External icing (clause 5.6) |
| ̀ Hose down (clause 5.7) |
| ̀ 4X corrosion protection (clause 5.10) |
| ̀ Gasket (clause 5.14) |
| ˿ Withstands 5-ft. (1.5-m) drop |
| ˿ Connector: MIL-C-26482 |
| ˿ Rotational backplate for 360º of roll |
Electrical
| ˿ Power consumption: 9 W |
| ˿ Power supply voltage: 10–28 VDC * |
| ̀ Recommended power supply voltage: 12–24 VDC * |
| ˿ Onboard surge protection |
Ordering information SmartSensor Matrix
SS-225
Accessories 102-0416/102-0451 – Click 650/656 CLK-112/114 – Click 112/114 SS-704-xxx/705 – SmartSensor 6-conductor Cable SS-611 – SmartSensor Mount 101-0462 – Span Wire Mount SS-B01-0003/0005/0008 – Intersection Preassem-bled Backplate – AC SS-B01-0004/0006 – Intersection Preassembled Backplate – DC SS-B02-0002/0003 – Intersection Preassembled 19-inch Rack SS-710 – Sensor Cable Junction Box
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
* While the system works with supply voltages of up to 28 VDC, 24 VDC supplies are recommended; the excess is designed to allow some tolerance on the output of the supply.
To support 12 VDC battery systems, and if the cable is short enough, the sensor can accept a power supply as low as 10 VDC; however, if the cable exceeds ### ft. in length, the power supply must be at least 12 VDC.
Communication ports ˿ Two half-duplex RS-485 COM ports support:
| ̀ Dedicated detection communications |
| ̀ Configuration, verification or traffic display without disrupt- |
ing detection communications
| ˿ Firmware upgradability over any COM port |
| ˿ User configurable: |
| ̀ Response delay |
| ̀ Push port |
Radar design
| ˿ Operating frequency: 24.0–24.25 GHz (K-band) |
| ˿ Matrix of 16 radars |
| ˿ No manual tuning to circuitry |
| ˿ Uses frequency modulated continuous wave (FMCW) radar |
| ˿ No temperature-based compensation necessary |
| ˿ Bandwidth stable within 1% |
| ˿ Printed circuit board antennas |
| ˿ Antenna vertical 6 dB beam width (two-way pattern): 65° |
| ˿ Horizontal field of view: 90º |
| ˿ Antenna two-way sidelobes: -40 dB |
| ˿ Transmit bandwidth: 245 MHz |
| ˿ Un-windowed resolution: 2 ft. (0.6 m) |
| ˿ RF channels: 8 |
| ˿ Self-test for verifying hardware functionality |
| ˿ Diagnostics mode for verifying system functionality |
Configuration ˿ Automatic and manual configuration of lanes, stop bars and zones
| ˿ Lane positioning increment: 1 ft. (0.3 m) |
| ˿ Four-sided zones of any shape and size |
| ˿ Overlapping zones supported |
| ˿ Sensor reconfiguration without detection disruption supported |
| ˿ Graphical user interface with traffic pattern display |
| ˿ Counting and pulse channels supported |
| ˿ Supported operating systems: |
| ̀ Windows 7 |
| ̀ Windows 8 |
| ̀ Windows 10 |
| ˿ Software-supported functionality: |
| ̀ TCP/IP connectivity |
| ̀ Sensor configuration backup and restore |
| ̀ Backed-up sensor configurations can be viewed and |
edited ̀ Real-time traffic visualization for performance verification and traffic display
| ̀ Zone and channel actuation display |
| ̀ Virtual sensor connections for demonstration and training |
| ̀ Local or remote sensor firmware upgradability |
Operating conditions ˿ Accurate performance in:
| ̀ Rain up to 1 in. (2.5 cm) per hour |
| ̀ Freezing rain |
| ̀ Dry snowfall and moist snowfall |
| ̀ Wind |
| ̀ Dust |
| ̀ Fog |
| ̀ Changing temperature |
| ̀ Changing lighting (even direct light on sensor at dawn and |
dusk) ̀ Ice and dry snow buildup up to 0.2 in. (0.5 cm) on sensor front
| ˿ Ambient operating temperature: -40°F to 165°F (-40°C to 74°C) |
| ˿ Humidity: Up to 95% RH (non-condensing) |
Testing
| ˿ Tested under FCC CFR 47, part 15, section 15.249 |
| ˿ FCC certification on product label |
| ˿ FCC regulation-compliant for life of the sensor |
| ˿ Tested under IEC 61000-4-5 class 4 (lightning surge protection) |
| ˿ Tested under NEMA TS 2-2003 |
| ̀ Shock pulses of 10 g, 11 ms half sine wave |
| ̀ Vibration of 0.5 g up to 30 Hz |
| ̀ 300 V positive/negative pulses |
| ̀ Stored at -49ºF (-45ºC) for 24 hours |
| ̀ Stored at 185ºF (85ºC) for 24 hours |
| ̀ Operation at -29.2ºF (-34ºC) and 10.8 VDC |
| ̀ Operation at -29.2ºF (-34ºC) and 26.5 VDC |
| ̀ Operation at 165.2ºF (74ºC) and 26.5 VDC |
| ̀ Operation at 165.2ºF (74ºC) and 10.8 VDC |
Manufacturing
| ˿ Manufactured in the USA |
| ˿ Surface mount assembly |
| ˿ IPC-A-610C Class 2–compliant |
| ˿ Operational testing: |
| ̀ Sub-assembly test |
| ̀ 48-hour unit level burn-in |
| ̀ Final unit test |
˿ Unit test results available
Support
| ˿ Training and tech support available from Wavetronix |
| ˿ Wavetronix training includes: |
̀ Installation and configuration instruction to ensure accu-rate performance
| ̀ Classroom and in-field instruction |
| ̀ Knowledgeable trainers |
| ̀ Use of presentation materials |
| ̀ Virtual configuration using computer playback |
| ˿ Wavetronix tech support includes: |
̀ Technical representatives available for installation and configuration
̀ Ongoing troubleshooting and maintenance support
Documentation
| ˿ Instructional training guide |
| ˿ Comprehensive user guide |
| ˿ Installer quick-reference guide |
| ˿ User quick-reference guide |
| ˿ Certification documentation available upon request |
Warranty ˿ Two-year warranty against material and workmanship defects
(see SmartSensor Warranty datasheet for complete details)
The advertised detection accuracy of the company’s sensors is based on both external and internal testing, as outlined in each product’s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
Bid specifications
1.0 General. This item shall govern the purchase of aboveground radar presence detector (RPD) equivalent to the Wavetronix SmartSensor Matrix.
An RPD detects vehicles by transmitting electromagnetic radar signals through the air. The signals bounce off vehicles in their paths and part of the signal is returned to the RPD. The returned signals are then processed to determine traffic parameters.
RPDs are not affected by normal weather and environmental conditions such as rain, wind, dry snowfall, moist snowfall, dust, etc. They also do not require cleaning and can maintain performance over a wide range of ambient temperatures.
RPDs provide a non-intrusive means of detecting traffic. This property not only makes them safer to install but also more cost effective than sensors that require roadway modifications or placement.
2.0 Sensor outputs. The RPD shall present real-time presence data across a 140-ft. (42.7-m) range.
The RPD shall support a minimum of 16 zones.
The RPD shall support a minimum of 16 channels.
The RPD shall support user-selectable zone to channel mapping.
The RPD shall use AND logic to trigger channels when all selected zones are active.
The RPD shall use OR logic to combine multiple zones to a channel output, and shall have channel output extend and delay functionality.
The RPD algorithms shall mitigate detections from wrong way or cross traffic.
The RPD system shall have fail-safe mode capabilities for contact closure outputs if communication is lost.
3.0 Detectable area.
3.1 Detection range. The RPD shall be able to detect and report presence in lanes with boundaries as close as 6 ft. (1.8 m), measured laterally, from the RPD.
The RPD shall be able to detect and report presence in lanes located within the 140 ft. (42.7 m) arc, measured laterally, from the RPD.
3.2 Field of view. The RPD shall be able to detect and report presence for vehicles within a 90 degree field of view.
3.3 Lane configuration. The RPD shall be able to detect and report presence in up to 10 lanes.
The RPD shall be able to detect and report presence in curved lanes and areas with islands and medians.
4.0 System hardware. For each approach to be detected, one RPD corner radar shall be used.
4.1 Connectivity and surge. Each RPD shall be used with a preassembled backplate or a cabinet interface device.
If a traffic cabinet preassembled backplate, it shall have the following:
| • | AC/DC power conversion |
| • | Surge protection |
| • | Terminal blocks for cable landing |
| • | Communication connection points |
| • | The preassembled backplate for the RPD shall be a cabinet side mount or rack mount |
If a cabinet interface device, it shall be a single device that performs the following functions:
| • | Provide DC power to up to four connected sensors |
| • | Provide surge protection for those sensors |
| • | Communicate between the device and a connected computer |
| • | Communicate with contact closure devices and/or a traffic controller |
4.2 Contact closure input file cards. The RPD may use contact closure input file cards with 2 or 4 channel capabilities.
The contact closure input file cards for the RPD shall be compatible with industry standard detector racks.
5.0 Maintenance. The RPD shall not require cleaning or adjustment to maintain performance.
The RPD shall not rely on battery backup to store configuration information, thus eliminating any need for battery replacement.
Once the RPD is calibrated, it shall not require recalibration to maintain performance unless the roadway configuration changes.
The mean time between failures shall be 10 years, which is estimated based on manufacturing techniques.
6.0 Physical properties. The RPD shall not exceed 4.2 lbs. (1.9 kg) in weight.
The RPD shall not exceed 13.2 in. by 10.6 in. by 3.3 in. (33.5 cm x 26.9 cm x 8.4 cm) in its physical dimensions.
All external parts of the RPD shall be ultraviolet-resistant, corrosion-resistant, and protected from fungus growth and moisture deterioration.
6.1 Enclosure. The RPD shall be enclosed in a Lexan EXL polycarbonate.
The enclosure shall be classified “f1” outdoor weatherability in accordance with UL 746C.
The RPD shall be classified as watertight according to the NEMA 250 standard.
The RPD enclosure shall conform to test criteria set forth in the NEMA 250 standard for type 4X enclosures. Test results shall be pro-vided for each of the following type 4X criteria:
| • | External icing (NEMA 250 clause 5.6) |
| • | Hose-down (NEMA 250 clause 5.7) |
| • | 4X corrosion protection (NEMA 250 clause 5.10) |
| • | Gasket (NEMA 250 clause 5.14) |
The RPD shall be able to withstand a drop of up to 5 ft. (1.5 m) without compromising its functional and structural integrity.
The RPD enclosure shall include a connector that meets the MIL-C-26482 specification. The MIL-C-26482 connector shall provide contacts for all data and power connections.
7.0 Electrical. The RPD shall consume less than 10 W.
The RPD shall operate with a DC input between 10 VDC and 28 VDC.
The RPD shall have onboard surge protection.
8.0 Communication ports. The RPD shall have two communication ports, and both ports shall communicate independently and simultaneously.
Two independent communication ports allow one port to be used for configuration, verification and traffic monitoring without interrupting communications on the dedicated data port.
The RPD shall support the upload of new firmware into the RPD’s non-volatile memory over either communication port.
The RPD shall support the user configuration of the following:
| • | Response delay |
| • | Push port |
The communication ports shall support a 9600 bps baud rate.
9.0 Radar design. The RPD shall be designed with a matrix of 16 radars.
The matrix of 16 radars enables the sensor to provide detection over a large area and to discriminate lanes.
9.1 Frequency stability. The circuitry shall be void of any manual tuning elements that could lead to human error and degraded perfor-mance over time.
The RPD shall use frequency modulated continuous wave (FMCW) radar. All transmit modulated signals shall be generated by means of digital circuitry, such as a direct digital synthesizer, that is referenced to a frequency source that is at least 50 parts per million (ppm) stable over the specified temperature range, and ages less than 6 ppm per year. Any upconversion of a digitally generated modulated signal shall preserve the phase stability and frequency stability inherent in the digitally generated signal.
This specification ensures that, during operation, the RPD strictly conforms to FCC requirements and that the radar signal quality is maintained for precise algorithmic quality. Analog and microwave components within an RPD have characteristics that change with temperature variations and age. If the output transmit signal is not referenced to a stable frequency source, then the RPD is likely to experience unacceptable frequency variations which may cause it to transmit out of its FCC allocated band and thus will be non-compliant with FCC regulations.
The RPD shall not rely on temperature compensation circuitry to maintain transmit frequency stability.
Temperature-based compensation techniques have been shown to be insufficient to ensure transmit frequency stability. One reason this type of technique is not sufficient is that it does not compensate for frequency variations due to component aging.
The bandwidth of the transmit signal of the RPD shall not vary by more than 1% under all specified operating conditions and over the expected life of the RPD.
The bandwidth of an RPD directly affects the measured range of a vehicle. A change in bandwidth causes a direct error in the mea-sured range, i.e., a 5% change in bandwidth would cause a range error of 10 ft. (3 m) for a vehicle at 200 ft. (61 m). If the bandwidth changes by more than 1% due to seasonal temperature variations and component aging, then the RPD will need to be frequently reconfigured to maintain the specified accuracy.
9.2 Antenna design. The RPD antennas shall be designed on printed circuit boards.
Printed circuit board antennas eliminate the need for RF connectors and cabling that result in decreased reliability. Printed circuit antennas are less prone to physical damage due to their extremely low mass.
The vertical beam width of the RPD at the 6 dB points of the two-way pattern shall be 65 degrees or greater.
The antennas shall cover a 90 degree horizontal field of view.
The sidelobes in the RPD two-way antenna pattern shall be -40 dB or less.
Low sidelobes ensure that the performance from the antenna beam widths is fully achieved.
9.3 Resolution. The RPD shall transmit a signal with a bandwidth of at least 245 MHz.
The bandwidth of the transmit signal translates directly into radar resolution, which contributes directly to detection performance. For example, an RPD that transmits at a low bandwidth will have low radar resolution, which could cause it to count a single vehicle as two vehicles in adjacent lanes. As another example of the adverse effects of low radar resolution, the response from a sign or other radar target in the roadway may spill over into the lanes of travel and desensitize the radar. In order to achieve the specified detec-tion accuracy in a variety of conditions, the unwindowed radar resolution cannot be larger than 2 ft. (0.6 m) at the half-power level, which requires a bandwidth of 240 MHz. The high radar resolution reduces the problem of vehicle responses getting drowned out by brighter vehicles in adjacent lanes and improves performance for moving and stopped vehicles near roadway targets.
9.4 RF Channels. The RPD shall provide at least 8 RF channels so that multiple units can be mounted in the same vicinity without caus-ing interference between them.
9.5 Verification. The RPD shall have a self-test that is used to verify correct hardware functionality.
The RPD shall have a diagnostics mode to verify correct system functionality.
10.0 Configuration.
10.1 Auto-configuration. The RPD shall have a method for automatically defining traffic lanes, stop bars and zones without requiring user intervention. This auto-configuration process shall execute on a processor internal to the RPD and shall not require an external PC or other processor.
The auto-configuration process shall work under normal intersection operation and may require several cycles to complete.
10.2 Manual configuration. The auto-configuration method shall not prohibit the ability of the user to manually adjust the RPD configuration.
The RPD shall support the configuring of lanes, stop bars and detection zones in 1-ft. (0.3-m) increments.
When lanes have variable widths or have variable spacing (e.g. gore between lanes), precise resolution is necessary.
10.3 Windows-based software. The RPD shall include graphical user interface software that displays all configured lanes and the cur-rent traffic pattern using a graphical traffic representation.
A visual representation of traffic patterns allows an installer to quickly associate specific detections with corresponding vehicles, and it facilitates verification of RPD performance.
The RPD shall include the ability to do counting and pulse channels.
The graphical interface shall operate on Windows 7, Windows 8, and Windows 10 in the .NET framework.
The software shall support the following functionality:
| • | Operate over a TCP/IP connection |
| • | Give the operator the ability to save/back up the RPD configuration to a file or load/restore the RPD configuration from a file |
| • | Allow the backed-up sensor configurations to be viewed and edited |
| • | Provide zone and channel actuation display |
| • | Provide a virtual connection option so that the software can be used without connecting to an actual sensor |
| • | Local or remote sensor firmware upgradability |
11.0 Operating conditions. The RPD shall maintain accurate performance in all weather conditions, including rain, freezing rain, dry snow-fall, moist snowfall, wind, dust, fog and changes in temperature and light, including direct light on sensor at dawn and dusk. The RPD shall maintain accurate performance with ice and dry snow buildup on the sensor front.
RPD operation shall continue in rain up to 1 in. (2.5 cm) per hour.
The RPD shall be capable of continuous operation over an ambient temperature range of -40°F to 165.2°F (-40°C to 74°C).
The RPD shall be capable of continuous operation over a relative humidity range of 5% to 95% (non-condensing).
Dry snow and moist snow are terms defined by the International Hydrological Program of the United Nations in the publication “The Internation-al Classification For Seasonal Snow on the Ground.” Dry snow has a water volume content of 0% and moist snow has water content of less than 3%. Wet snow has higher fractional volumes of water and varying fractional volumes of air. Depending on the precipitation rate and the fraction-al volumes of ice, air, and water, the RPD shall be capable of continuous operation in wet snowfall. For example, with typical fractional volumes of ice, air, and water the RPD shall be capable of continuous operation in wet snowfall with a precipitation rate less than 1 in. per hour (2.5 cm) per hour. Furthermore, as instructed in the user documentation, the sensor should be installed with a down tilt for accurate detection. A down tilt alignment will also help shield the sensor front and minimize the possibility of dry, moist, and wet snow buildup in extreme weather conditions.
12.0 Testing.
12.1 FCC. Each RPD shall be certified by the Federal Communications Commission (FCC) under CFR 47, part 15, section 15.249 as an intentional radiator.
The FCC certification shall be displayed on an external label on each RPD according to the rules set forth by the FCC.
The RPD shall comply with FCC regulations under all specified operating conditions and over the expected life of the RPD.
The RPD shall be tested under IEC 61000-4-5 class 4 (lightning surge protection).
12.2 NEMA TS 2-2003 testing. The RPD shall comply with the applicable standards stated in the NEMA TS 2-2003 standard. Third-party test results shall be made available for each of the following tests:
| • | Shock pulses of 10 g, 11 ms half sine wave |
| • | Vibration of 0.5 g up to 30 Hz |
| • | 300 V positive/negative pulses applied at one pulse per second at minimum and maximum DC supply voltage |
| • | Cold temperature storage at -49°F (-45°C) for 24 hours |
| • | High temperature storage at 185°F (85°C) for 24 hours |
| • | Low temp, low DC supply voltage at -29.2°F (-34°C) and 10.8 VDC |
| • | Low temp, high DC supply voltage at -29.2°F (-34°C) and 26.5 VDC |
| • | High temp, high DC supply voltage at 165.2°F (74°C) and 26.5 VDC |
| • | High temp, low DC supply voltage at 165.2°F (74°C) and 10.8 VDC |
13.0 Manufacturing. The RPD shall be manufactured and assembled in the USA.
The internal electronics of the RPD shall utilize automation for surface mount assembly, and shall comply with the requirements set forth in IPC-A-610C Class 2, Acceptability of Electronic Assemblies.
The RPD shall undergo a rigorous sequence of operational testing to ensure product functionality and reliability. Testing shall include the following:
| • | Functionality testing of all internal sub-assemblies |
| • | Unit level burn-in testing of 48 hours’ duration or greater |
| • | Final unit functionality testing prior to shipment |
Test results and all associated data for the above testing shall be provided for each purchased RPD by serial number, upon request.
14.0 Support. The RPD manufacturer shall provide both training and technical support services.
14.1 Training. The manufacturer-provided training shall be sufficient to fully train installers and operators in the installation, configura-tion, and use of the RPD to ensure accurate RPD performance.
The manufacturer-provided training shall consist of comprehensive classroom labs and hands-on, in-the-field, installation and configu-ration training.
Classroom lab training shall involve presentations outlining and defining the RPD, its functions, and the procedures for proper opera-tion. These presentations shall be followed by hands-on labs in which trainees shall practice using the equipment to calibrate and configure a virtual RPD. To facilitate the classroom presentation and hands-on labs, the manufacturer-provided training shall include the following items:
| • | Knowledgeable trainer or trainers thoroughly familiar with the RPD and its processes |
| • | Presentation materials, including visual aids, printed manuals and other handout materials for each student |
| • | Computer files, including video and raw data, to facilitate the virtual configuration of the RPD |
| • | Laptop computers or Windows CE handheld devices with the necessary software, and all necessary cables, connectors, etc. |
| • | All other equipment necessary to facilitate the virtual configuration of the RPD |
Field training shall provide each trainee with the hands-on opportunity to install and configure the RPD at roadside. Training shall be such that each trainee will mount and align the RPD correctly.
14.2 Technical assistance. Manufacturer-provided technical support shall be available according to contractual agreements, and a technical representative shall be available to assist with the physical installation, alignment, and auto-configuration of each supplied
RPD. Technical support shall be provided thereafter to assist with troubleshooting, maintenance, or replacement of RPDs should such services be required.
15.0 Documentation. RPD documentation shall include an instructional training guide and a comprehensive user guide as well as an in-staller quick-reference guide and a user quick-reference guide.
Certification documentation shall be available upon request.
16.0 Warranty. The RPD shall be warranted free from material and workmanship defects for a period of two years from date of shipment.
The advertised detection accuracy of the company’s sensors is based on both external and internal testing, as outlined in each product’s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
Installation specifications
1.0 General. This item shall govern the installation of an aboveground radar presence detector (RPD) equivalent to the Wavetronix SmartSensor Matrix.
RPDs can provide accurate, consistent, and reliable presence detections provided they are installed properly. The requirements in this specification are intended to ensure proper RPD installation.
2.0 Mounting and installation.
2.1 Mounting assembly. The RPD shall be mounted directly onto a mounting assembly fastened to a mast arm, pole or other solid structure. In qualifying tethered (double) span wire intersections, the mounting assembly may be fasted to a hanger assembly that is affixed to the span wire.
The RPD mounting assembly shall provide the necessary degrees of rotation to ensure proper installation.
The RPD mounting assembly shall be constructed of weather-resistant materials and shall be able to support a 20-lb. (9.1-kg) load.
2.2 Mounting location. The RPD shall be mounted at a height that is within the manufacturer’s recommended mounting heights.
The RPD shall be mounted at an offset from the first lane that is consistent with the RPD’s minimum offset.
The RPD shall be mounted so that at least 20 feet along the farthest lane to be monitored is within the field view of the RPD.
The RPD shall be mounted with its cable connector down and shall be tilted so that the RPD is aimed at the center of the lanes to be monitored. Typically, the RPD is tilted off of vertical by 20–30 degrees.
The RPD shall be mounted on a vertical signal pole or on the horizontal mast arm, or, in qualifying tethered (double) span wire intersec-tions, on the span wire.
The RPD shall be mounted so that its field of view is not occluded by poles, signs or other structures.
RPDs that are mounted within 20 ft. (6.1 m) of each other or that are monitoring the same intersection shall be configured to operate on different RF channels regardless of the pointing direction of the RPDs.
It is recommended that the manufacturer be consulted to verify final RPD placement if the RPD is to be mounted near large planar surfaces (sound barrier, building, parked vehicles, etc.) that run parallel to the monitored roadway.
2.3 Cabling. The cable end connector shall meet the MIL-C-26482 specification and shall be designed to interface with the appropri-ate MIL-C-26482 connector. The connector backshell shall be an environmentally sealed shell that offers excellent immersion capa-bility. All conductors that interface with the connector shall be encased in a single jacket, and the outer diameter of this jacket shall be within the backshell’s cable O.D. range to ensure proper sealing. The backshell shall have a strain relief with enough strength to support the cable slack under extreme weather conditions. Recommended connectors are Cannon’s KPT series, and recommended backshells are Glenair Series 37 cable sealing backshells.
The cable shall be the Wavetronix SS-704-xxx or an equivalent cable that conforms to the following specifications:
| • | The RS-485 conductors shall be a twisted pair. |
| • | The RS-485 conductors shall have nominal capacitance conductor to conductor of less than 40 pF/ft. at 1 kHz. |
| • | The RS-485 conductors shall have nominal conductor DC resistance of less than 16.7 ohms/1000 ft. (304.8 m) at 68°F (20°C). |
| • | The power conductors shall be one twisted pair with nominal conductor DC resistance of less than 11.5 ohms/1000 ft. (304.8 m) at |
68°F (20°C).
• Each wire bundle or the entire cable shall be shielded with an aluminum/mylar shield with a drain wire.
The cable shall be terminated only on the two farthest ends of the cable.
The cable length shall not exceed 2000 ft. (609.6 m) for the operational baud rate of RS-485 communications (9.6 Kbps).
If 12 VDC is being supplied for the RPD then the cable length shall not exceed 110 ft. (33.5 m).
If 24 VDC is being supplied for the RPD then the cable length shall not exceed 600 ft. (182.9 m).
Both communication and power conductors can be bundled together in the same cable as long as the abovementioned conditions are met.
2.4 In-cabinet interface equipment. The RPD shall be installed using the Click 600, 650 or 656 cabinet interface device, a Wavetronix preassembled backplate, or an equivalent that provides input power surge suppression, sensor cable surge suppression, AC to DC power conversion (if necessary), and terminal blocks.
2.5 Lightning surge protection. The RPD has onboard surge protection; proper grounding is required for effective surge protection.
Consult the article titled Intersection Grounding Schematics in the knowledge base on the Wavetronix website for more information.
Appropriate lightning surge protection shall be installed in the traffic cabinet to protect the cabinet equipment. These lightning surge protection devices shall meet or exceed the IEC 61000-4-5 Class 4 specifications. The Wavetronix Click 222 and Click 65x devices both meet those standards. The lightning surge protection unit supplied shall be physically compatible with the cable provided.
2.6 Power supply. The RPD shall be installed using the Click 65x, the Click 202 or Click 204 (included on the Wavetronix preassem-bled backplate), or an equivalent AC to DC power converter that meets the following specifications:
The power converter shall be power rated at 48 W for temperatures less than 140°F (60°C) with a 5% power decrease for each degree Celsius increase up to 158°F (70°C).
The power converter shall operate in the temperature range of to -29.2°F to 165.2°F (–34°C to 74°C).
The power converter shall operate in the humidity range of 5% to 95% at 77°F (25°C) non-condensing.
The power converter shall accept an input voltage of 85 to 264 VAC or 120 to 370 VDC.
The power converter shall operate at an input frequency of 47 Hz to 63 Hz.
The power converter shall produce an output voltage of 24 VDC ±4%.
The power converter shall withstand a voltage across its input and output of 3 kV. The power converter shall withstand a voltage across its input and ground of 1.5 kV.
The power converter shall conform to safety standards UL 60950-1 and EN 60950-1 and be certified and tested to meet the limited power source requirement according to clause 2.5. Its output current shall be limited to a maximum current of 4A both under normal and single fault condition; with double/reinforced insulation between its input and output circuits.
The power converter shall conform to EMC standards EN 55022 Class B and EN 61000-3-2, 3.
In brown-out conditions (i.e. < 85 VAC input), the output voltage of the power converter shall be less than 1 VDC.
The terminal blocks shall be color-coded insulation displacement terminal blocks.
The terminal blocks shall be prewired to the other in-cabinet equipment so that no wiring other than cable terminations, connecting input power and connecting input file cards shall be required during installation.
2.7 Input file cards. The Click 114, Click 112 or an equivalent that meets the following specifications shall be used when using a preas-sembled backplate or Click 600:
The input file cards shall be compatible with 170, 2070, NEMA TS 1, and NEMA TS 2 style input racks.
The input file card shall translate data packets from the RPD into contact closure outputs.
The input file card shall support presence detection.
The input file card shall receive data packets over an RS-485 bus at a baud rate of 9600 bps.
The input file card shall autobaud and auto-detect an RPD over wired and wireless communication channels that have a maximum latency of 500 ms.
The input file card shall comply with the NEMA TS 2-1998 or newer Traffic Controller Assemblies with NTCIP Requirements (Section 2.8 specification).
SmartSensor Advance Extended Range
Forward–fire long–distance intersection sensor SmartSensor Advance Extended Range is the first traffic device to use advance detection to provide enhanced dilemma zone protection for trucks and other high profile vehicles. The sensor boosts detection of these vehicles out to 900 feet, and protects both cars and trucks with innovative SafeArrival technology.
˿ Dilemma zone protection for high-profile vehicles based on vehicle discovery range
˿ Advanced techniques boost truck detections out to 900 feet; car detections are boosted out to 600 feet or more
˿ Patented SafeArrival technology provides protection to individual cars and trucks
˿ Dynamic ETA Tracking over the entire detection area
˿ Non-intrusive, above ground position makes the sensor easy to install
˿ The additional 300-foot range
(compared to SmartSensor Advance) makes overhead/ straightforward mast arm installa-tion more effective on high-speed approaches
˿ Easily integrates with SmartSensor Matrix at intersections
˿ Benefits include reduced risk of hazardous load spills; reduced truck crash and fatalities rates;
reduced emissions; fewer truck start-up delays; and improved corridor delivery times
1827 W 650 N, Springville, UT 84663, US • (801) 734-7200 • www.wavetronix.comWX-500-0270 Part No: SS-200E
WX-500-0270
Part No: SS-200E
Physical properties
| ˿ Weight: 3.8 lbs. (1.7 kg) |
| ˿ Dimensions: 13.2 in. × 10.6 in. × 3.8 in. (33.5 cm × 26.9 cm × 9.7 cm) |
| ˿ Enclosure: |
| ̀ Lexan EXL polycarbonate |
| ̀ Resistant to corrosion, fungus, moisture deterioration and |
ultraviolet rays
| ̀ Outdoor weatherable: UL 746C |
| ̀ Withstands 5-ft. (1.5-m) drop |
| ̀ Watertight by NEMA 250 standard |
| ˿ Connector: MIL-C-26482 |
| ˿ Rotational backplate for 360º of roll |
Radar design
| ˿ Type of radar: Single-beam |
| ˿ Uses frequency modulated continuous wave (FMCW) radar |
| ˿ Operating frequency: 10.5–10.55 GHz (X-band) |
| ˿ Transmit bandwidth: 45 MHz |
| ˿ Bandwidth stable within 1% |
| ˿ Un-windowed resolution: 11 ft. (3.4 m) |
| ˿ Antennas: |
| ̀ Printed circuit board antennas |
| ̀ Vertical 6 dB beam width (two-way pattern): 65° |
| ̀ Horizontal 6 dB beam width (two-way pattern): 10.5° |
| ̀ Two-way sidelobes -40 dB |
| ˿ RF channels: 8 |
| ˿ No manual tuning to circuitry |
| ˿ No temperature-based compensation necessary |
Detection area
| ˿ Detection area: 50 to 900 ft. (15.2 m to 274.3 m) |
| ˿ Discovery range threshold from 100 ft. (30.5 m) to 900 ft. (274.3 m) |
| ˿ Maximum mounting height: 40 ft. (12.2 m) |
| ˿ Maximum mounting distance from center of lanes: 50 ft. (15.2 m) |
Measured quantities ˿ Per-vehicle data:
| ̀ Range |
| ̀ Speed |
| ̀ ETA |
| ˿ Number of channels: 8 |
| ˿ Channel outputs: 8 |
| ̀ Alerts per channel: 4 (32 total) |
| ̀ Zones per alert: 4 (128 total) |
| ˿ Number of simultaneous vehicle detections: 25 |
| ˿ Priority channels: 3 |
| ˿ Dynamic density (a measure of instantaneous roadway efficiency) |
Power ˿ Power consumption: 3.2 W @ 12 VDC
Ordering information SmartSensor Advance Extended Range
SS-200E
Retrofitted SmartSensor Advance Extended Range
SS-200E-001
Accessories 102-0597 – Arc2 102-0594 – Arc6 102-0525 – SmartSensor Surge 102-0416/102-0451 – Click 650/656 cabinet interface device CLK-112/114 – Click 112/114 rack cards SS-704-xxx/705 – SmartSensor 8-conductor cable (for retrofitted sensor) SS-611 – SmartSensor Mount SS-B01-0003/0005/0008 – Intersection Preassem-bled Backplate – AC SS-B01-0004/0006 – Intersection Preassembled Backplate – DC SS-B02-0002/0003 – Intersection Preassembled 19-inch Rack SS-710 – Sensor Cable Junction Box
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
SmartSensor Advance Extended Range technical specifications
* While the system works with supply voltages of up to 28 VDC, 24 VDC supplies are recommended; the excess is designed to allow some tolerance on the out-put of the supply. To support 12 VDC battery systems, and if the cable is short enough, the sensor can accept a power supply as low as 10 VDC; however, this is dependent on cable length and wire gauge. Please consult Knowledge Base Article 0381, SmartSensor Advance Cable Length Recommendations, for details.
Part No: SS-200E
| ˿ Operating voltage: 10–28 VDC * |
| ̀ Recommended power supply voltage: 12–24 VDC * |
˿ Onboard surge protection
Communication ˿ Com ports:
| ̀ Two half-duplex RS-485 COM |
| ˿ User configurable: |
| ̀ Baud rate |
| ̀ Response delay |
| ̀ Contact closure data output frequency |
| ˿ Supported baud rates: |
| ̀ 9600 |
| ̀ 19200 |
| ̀ 38400 |
| ̀ 57600 |
| ̀ 115200 |
| ˿ Contact closure data output frequency: |
| ̀ Minimum: 10 ms |
| ̀ Default: 130 ms |
˿ Contact closure data latency (varies with baud rate and output frequency):
̀ Minimum: 55 ms (this is achieved using 57600 bps baud rate and 50 ms output frequency)
̀ Default: 142 ms (this is achieved using 9600 bps baud rate and 130 ms output frequency)
| ˿ Firmware upgradability over any COM port |
| ˿ Dedicated detection communications |
| ˿ Configuration, verification, or traffic display without disrupting |
detection communications ˿ Detection data available via serial communications
Configuration
| ˿ Graphical user interface with traffic representation |
| ˿ Automatic and manual configuration of detection sensitivity in |
7.5-ft. (2.29-m) increments
| ˿ Manual configuration supported |
| ˿ Zone size increment: 5 ft. (1.5 m) |
| ˿ Maximum detection zone size: 850 ft. (251.9 m) |
| ˿ High speed and low speed detection filters: |
| ̀ Speed filter increment: 1 mph (1.6 kph) |
| ˿ Upper and lower ETA filters |
| ̀ ETA filter increment: 0.1 seconds |
| ˿ Upper and lower count filters |
| ̀ Count filter increment: 1 |
| ˿ Display of configured alerts and their actuation |
| ˿ Vehicle track file logging |
| ˿ Supported operating systems: |
| ̀ Windows 7 |
| ̀ Windows 8 |
| ̀ Windows 10 |
| ˿ Software supported functionality: |
| ̀ TCP/IP connectivity |
| ̀ Auto-find baud rate |
| ̀ Auto-find serial port |
| ̀ Virtual sensor connections |
| ̀ Sensor configuration backup and restore |
| ̀ Dynamic stop-bar ETA tracking adjusted as vehicles |
change speeds
| ̀ Channel output from multiple alerts |
| ̀ Delay and extend settings used for channel outputs |
| ̀ Combinational logic applied to zone outputs for alert output |
| ̀ Logic filters for zone output |
| ̀ Latched channel output controlled by alerts and timer |
| ̀ Pulse channel outputs for intersection arrival-time information |
| ̀ Priority level (based on discovery range for high-profile |
vehicles) ̀ Two priority level alerts: level 1 = high priority, level 2 = normal priority ̀ Queue clearance alert
Manufacturing
| ˿ Manufactured in the USA |
| ˿ Surface mount and wave solder assembly |
| ˿ IPC-A-610C Class 2–compliant |
| ˿ Operational testing: |
| ̀ Sub-assembly test |
| ̀ 48-hour unit level burn-in |
| ̀ Final unit test |
˿ Unit test results available
Testing
˿ NEMA:
| ̀ NEMA TS 2-2003 |
| ̀ NEMA 250 type 4X-compliant |
| ˿ FCC: |
| ̀ CFR 47 Part 15 |
| ̀ FCC regulation–compliant for life of the sensor |
| ̀ FCC certification on product label |
| ˿ CE: |
| ̀ Tested under IEC 61000-4-5 class 4 (lightning surge pro- |
tection)
Operating conditions
| ˿ Ambient operating temp: -29.2°F to 165°F (-34°C to 74°C) |
| ˿ Humidity: up to 95% RH (non-condensing) |
| ˿ Accurate performance in: |
| ̀ Rain up to 2 in. (5.08 cm) per hour |
| ̀ Freezing rain |
| ̀ Dry and moist snowfall |
| ̀ Wind |
| ̀ Dust |
Part No: SS-200E
| ̀ Fog |
| ̀ Changing temperature |
| ̀ Changing lighting (even direct light on sensor at dawn and |
dusk) ̀ Ice and dry snow buildup up to 0.2 in. (0.5 cm) on sensor front
Performance
| ˿ Detection accuracy: large vehicles 98%; all motor vehicles 95% |
| ˿ Range accuracy: ±10 ft. (3 m) for 90% of measurements |
| ˿ Speed accuracy: ±5 mph (8 kph) for 90% of measurements |
| ˿ ETA accuracy: ±1 sec. for 85% of measurements |
| ˿ Percentage of vehicles detected before 450 ft. (137.2 m): all |
motor vehicles 90% ˿ Percentage of vehicles detected before 700 ft. (213.4m): high-profile trucks, buses, and other large vehicles 90%
Maintenance
| ˿ No cleaning or adjustment necessary |
| ˿ No battery replacement necessary |
| ˿ No recalibration necessary |
| ˿ Mean time between failures: 10 years (estimated based on |
manufacturing techniques
Support
| ˿ Training and tech support available |
| ˿ Training includes: |
| ̀ Knowledgeable trainers |
| ̀ Presentation materials |
| ̀ Classroom and in-field instruction |
| ̀ Installation and configuration instruction to ensure accurate |
performance
| ̀ Instruction in use of computer and other necessary equipment |
| ̀ Virtual configuration |
| ˿ Technical support includes: |
| ̀ Technical representatives available for installation and |
configuration ̀ Ongoing troubleshooting and maintenance support
| ˿ Documentation: |
| ̀ Installation guide |
| ̀ Configuration guide |
| ̀ Quick start guide |
| ˿ Documentation available upon request: |
| ̀ Detection accuracy |
| ̀ Range accuracy |
| ̀ Earliest range of detection |
| ̀ Speed accuracy |
| ̀ ETA accuracy |
Warranty ˿ Two-year warranty against material and workmanship defect
(see SmartSensor Warranty datasheet for complete details)
The advertised detection accuracy of the company’s sensors is based on both external and internal testing, as outlined in each product’s specification document. Although our sensors are very accurate by industry standards, like all other sensor manufacturers we cannot guarantee perfection or assure that no errors will ever occur in any particular applications of our technology. Therefore, beyond the express Limited Warranty that accompanies each sensor sold by the company, we offer no additional representations, warranties, guarantees, or remedies to our customers. It is recommended that purchasers and integrators evaluate the accuracy of each sensor to determine the acceptable margin of error for each application within their particular system(s).
SmartSensor Mount
Pole mount for SmartSensors The SmartSensor mount makes installation quick and easy by helping you securely mount any of the Wavetronix SmartSensors. Sturdily built of powder-coated aluminum for durability and weather-resistance, this mount can withstand whatever the elements throw at it.
˿ Two axes of rotation for horizontal and vertical positioning
˿ Mates with fixed and rotational backplates on the SmartSensor V, HD, Advance, and Matrix
˿ Symmetric hole pattern for flex-ibility in sensor attachment
˿ Two contact points for attachment to circular or non-circular poles
˿ On circular poles, another axis of rotation around the pole is avail-able
| ˿ Accepts ¾” banding |
| ˿ Heavy duty aluminum construction |
makes mount sturdy and long-lasting
˿ Powder coated for oxidization resistance, allowing mount to withstand the harshest weather conditions
˿ Supports a 20-lb. (9.1-kg) load
8 in.6 in.
13.61 in.
3.79 in.
78 E 1700 S, Provo, UT 84606, US • (801) 734-7200 • www.wavetronix.comWX-500-0072 1 of 3
Mounting
| ˿ Rotational axes: 2 |
| ̀ NOTE: SmartSensor Advance and SmartSensor Matrix are |
shipped with rotational backplate for third axis of rotation.
SmartSensor V and SmartSensor HD can be ordered with rotational backplate if third axis is required.
| ˿ Maximum load: 20 lbs. (9.1 kg) |
| ˿ Symmetric hole pattern that mates with fixed and rotational |
SmartSensor backplates
| ˿ Contact points with pole: 2 |
| ˿ Slotted for ¾-in. (1.9-cm) banding |
| ˿ Additional degree of movement achieved by using the |
360-0129
Construction
| ˿ Constructed of aluminum 0.1875 in. (0.48 cm) thick |
| ˿ 316 stainless steel hardware |
| ˿ Powder coated |
| ˿ Weight: 3 lbs. (1.36 kg) |
Ordering information SmartSensor Mount
SS-611
Accessories 360-0129 – SmartSensor Mount Knuckle
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
1.0 General. This item shall govern the purchase of a traffic sensor mounting assembly equivalent to the Wavetronix SmartSensor™ mount.
2.0 �Mounting. The mounting assembly shall provide at least two axes of rotation to ensure proper installation.
The mounting assembly shall be able to support at least a 20-lb. (9.1-kg) load.
The mounting assembly shall feature a symmetric hole pattern that mates with fixed and rotational SmartSensor backplates.
The mounting assembly shall have two contact points with the pole.
The mounting assembly shall be slotted for 3/4-in. (1.9-cm) banding.
3.0 Construction. The mounting assembly be constructed of 0.1875 in. (0.48 cm) thick or thicker aluminum with 316 stainless steel hardware.
The mounting assembly shall be powder coated for oxidation resistance.
The mounting assembly shall weigh 3 lbs. (1.36 kg).
SmartSensor 6-conductor Cable
Power and dual–RS-485 sensor cable The SmartSensor 6-conductor cable is used with the SmartSensor Matrix and SmartSensor Advance to provide power and communication connectivity to the sensors. Heavy-duty and weather-resistant, this custom cable is ideal for cable runs from the sensor to the cabinet.
6-conductor cable that attaches to an 8-pin connector
Provides power and RS-485 com-munications between sensor and cabinet
Connector is keyed to ensure proper connection
Color-coded for quick and easy wiring to terminal blocks, Click modules
RS-485 and power conductors are twisted pairs
Cable assembly is shielded with aluminum/mylar shield and a tinned copper drain wire
RoHS compliant
Cable end connector backshell is environmentally sealed, oJering excellent immersion capability
Connector backshell supports ca-ble slack under extreme weather conditions
6-conductor cable 8-pin connector
78 E 1700 S, Provo, UT 84606, US # (801) 734-7200 # www.wavetronix.comWX-500-0074 1 of 3
Cable
RS-485 conductors: 2 twisted pairs
RS-485 conductor nominal capacitance, conductor to conduc-tor: less than 40 pF/ft. at 1 kHz
RS-485 conductor nominal conductor DC resistance: less than
16.7 ohms/1000 ft. (304.8 m) at 20°C
Power conductors: twisted pair with nominal conductor DC resistance of less than 11 ohms/1000 ft. (304.8 m) at 20°C
Cable assembly shielded with aluminum/polyester shield and tinned copper drain wire
Jacket: 0.053-in. (1.3-mm) gray PVC
Cable diameter: 0.41 in. (1.04 cm)
Wire gauges:
$ Power wires: 20 AWG
$ Comms wires: 22 AWG
RoHS compliant
Approvals: UL/cUL Type CMG
Ambient operating temperature: up to 221°F (105°C) dry / 167°F
(75°C) wet
Flammability rating: FT4
UV resistant: Yes (per UL 720 Hour Sunlight Resistance Test)
600 Volt AWM style 2587
Connector
Meets MIL-C-26482 specification
Backshell is environmentally sealed
Backshell oJers excellent immersion capability
All conductors that interface with the connector are encased in a single jacket
Backshell has a strain relief with enough strength to support the cable slack under extreme weather conditions.
Ordering information
SmartSensor 6-conductor Cable (set length, con-nectorized)
SS-704-006 (6-ft. cable)
SS-704-020 (20-ft. cable)
SS-704-040 (40-ft. cable)
SS-704-060 (60-ft. cable)
SS-704-080 (80-ft. cable)
SS-704-100 (100-ft. cable)
SmartSensor 6-conductor Cable (bulk spool, non-connectorized)
SS-705 — custom cable length (sold in 100-ft.
increments)
101-0448 (500-ft./152.4-m spool)
SS-705-001 (1000-ft./304.8-m spool)
SS-705-002 (5000-ft./1524-m spool)
8-pin Female Connector
SS-709
Contact us
801.734.7200 sales@wavetronix.com
1.0 General. This item shall govern the purchase of a tracc sensor–to–tracc cabinet cable equivalent to the Wavetronix SmartSensor
6-conductor cable.
2.0 Cable. The cable shall be the Orion Wire Combo-2204-2002-PVCGY or an equivalent cable that conforms to the following specifications:
• The RS-485 conductors shall be 2 twisted pairs.
• The RS-485 conductors shall have nominal capacitance conductor to conductor of less than 40 pF/ft. at 1 kHz.
• The RS-485 conductors shall have nominal conductor DC resistance of less than 16.7 ohms/1000 ft. at 20°C.
• The power conductors shall be a twisted pair.
• The power conductors shall have nominal conductor DC resistance of less than 11 ohms/1000 ft. at 20°C.
• The entire cable shall be shielded with an aluminum/polyester shield with a drain wire.
• The cable jacket shall be made of gray PVC that is 0.053 in. (1.3 mm) thick.
• The cable shall have a diameter of 0.41 in. (1.04 cm).
• The power wires in the cable shall be 20 AWG; the communications wires shall be 22 AWG.
• The cable shall be RoHS compliant.
• The cable shall have a UL/cUL type CMG safety approval.
• The cable shall be capable of operating at temperatures up to 221°F (105°C) while dry and 167°F (75°C)…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .