This specification document outlines bid requirements for a Cabinet Interface Device (CID) equivalent to the Wavetronix Click 656, a module designed for traffic management systems in Texas. The CID must provide power, surge protection, and communications capabilities for SmartSensors and contact closure devices through multiple connectivity options including SDLC, Ethernet, RS-485, RS-232, USB, and T-bus ports. The device shall support up to six SmartSensors with up to 64 total detector channels and must be compatible with standard 19-inch cabinet rack mounting or shelf-mounted installations. Physical specifications require the device not to exceed 6 pounds and dimensions of 6.6 inches by 5.125 inches by 7.3 inches, with operational temperature range from -29°F to 165°F and humidity tolerance up to 95% relative humidity.
The CID must meet stringent technical and compliance standards including NEMA TS2-2003 testing protocols, FCC compliance, and IEC/EN 61000-4-5 surge immunity standards at specified levels for both sensor ports and AC inputs. Power supply specifications require 100-240 VAC input at 50-60 Hz frequency with maximum power consumption of 112 watts at 80°C and 24 VDC output to sensor connectors. The device shall include four multicolored status LEDs, an OLED panel with keypad for on-site configuration, and a web interface for remote configuration and device discovery. Bidders must provide test results demonstrating performance and capabilities, and all units must pass manufacturer testing before shipment. The CID is warranted for two years against material and workmanship defects, with extended support options available from the manufacturer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| ESBD_476617_1765832621737_Bid Table 601440000050972.xlsx | XLSX spreadsheet | |
| ESBD_476617_1765832542992_01. IFB 601440000050972.pdf | ||
| Bid_notify_601440000050972.txt | TXT text file | |
| ESBD_476617_1765832586134_03. Execution of Bid.pdf | ||
| ESBD_476617_1765832602439_04. Texas Family Code Schedule.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Click 656
Cabinet interface device The Click 656 provides support for SmartSensor Matrix and Advance in one compact case. This module communicates directly to the controller through SDLC, and supports contact closure devices as well. It also provides power, surge protection, and Ethernet connectivity for all sensors.
˿ Provides power, connectivity, and surge protection for up to six SmartSensors
˿ Sends sensor detection data directly to controller through the SDLC port
˿ Provides up to 64 detector chan-nels via SDLC communications
˿ Can also be used to send sensor detection data to contact closure cards
˿ Provides an Ethernet port for network connectivity
˿ Has a power switch for each sensor, allowing you to easily turn them off one by one
˿ Has multiple configuration con-nections for communicating from your computer to the connected sensors:
| ̀ USB |
| ̀ RJ-11 jacks for RS-485 |
| ̀ DB-9 connector for RS-232 |
| ̀ T-bus port |
˿ Can be easily installed in standard 19” cabinet or used on a shelf
˿ Can be used in place of preassem-bled backplates and other cabinet devices
Click 656 cabinet interface device www.wavetronix.com
CONTROL
DATA
Status Ethernet
RXTXPort 1 SDLC
SDLC
Serial
+D C
-D C
+485 -485
GN
D
RDTDOKPW
Sensors 1-6
PW
R
PW
R
OLED Panel & Keypad FRONT
Data Bus RS-485 Connectors, Ethernet Port
Control Bus RS-485 Connectors, USB Connectors, SDLC LED Indicators, Port 1 SDLC, RS-232 Connector and LED Indicators
T-bus 5-position Connector
78 E 1700 S, Provo, UT 84606, US • (801) 734-7200 • www.wavetronix.comWX-500-0322 1 of 5
Technical specifications Included components
| ˿ Click 656 |
| ˿ AC power cord |
| ˿ Extra fuse |
| ˿ Terminal blocks for attaching to cable |
| ˿ Ethernet cable |
Physical
| ˿ Weight: 6 lbs. (2.72 kg) |
| ˿ Physical dimensions: 6.6 in. × 5.125 in. × 7.3 in. (16.8 cm x 13 cm |
x 18.5 cm)
| ˿ Ambient operating temp: -29°F to 165°F (-34°C to 74°C) |
| ˿ Humidity: up to 95% RH |
Mounting
| ˿ Shelf-mount |
| ˿ 19” rack-mount |
Power
| ˿ Power supply voltage: 100 to 240 VAC |
| ˿ AC frequency: 50–60 Hz |
| ˿ Max power: 112 W @ 80ºC |
| ˿ 24 VDC output on sensor connectors |
Connections and communication ˿ Power
| ̀ AC input: IEC AC input |
| ˿ Ethernet |
| ̀ One RJ-45 10/100 Ethernet jack on the front of the device |
| ˿ SDLC |
| ̀ One SDLC port on the front of the device |
| ˿ Six terminal block connectors on back of device for connecting |
to sensors ̀ Cable terminal points for sensor power and RS-485 communications
| ̀ Matching terminal blocks are included with Click 656 |
| ̀ Matches terminal blocks used for cable termination with |
Wavetronix intersection preassembled backplates ˿ Six RJ-11 jacks on faceplate of device for connecting to contact closure devices
| ̀ Communicate via RS-485 |
| ̀ Jacks make up physical interface of data bus on device |
and are for sending detection data from sensors on to contact closure devices such as rack cards (which are not included)
| ̀ Communicate with rack cards via jumper cables |
| ˿ Six communication ports on faceplate make up physical inter- |
face of control bus and are for connecting to the sensors to configure them
| ̀ DB-9 port for communicating via RS-232 |
| ̀ Two RJ-11 jacks for communicating via RS-485 |
| ̀ USB micro-B connector |
| ̀ T-bus port for connecting to a T-bus; allows Click 656 to |
send DC power and RS-485 communications to other devices connected to a T-bus
Other features ˿ Four multicolored LEDs with activity indicating functions:
| ̀ Red LED (PW) illuminates when device has power |
| ̀ Blue LED (OK) extinguishes if device has been disabled by |
surges ̀ Green LED (TD) illuminates when data is transmitted on the control bus ̀ Yellow LED (RD) illuminates when data is received on the control bus ˿ Each data bus RJ-11 jack on the faceplate corresponds to one sensor and has the following features:
| ̀ Switch for turning the power to that sensor on and off |
| ̀ LED for indicating when that sensor has power |
| ˿ Switch for turning power on and off to entire device |
| ˿ OLED panel and keypad for on-site device configuration |
| ˿ Web interface for device discovery and output configuration |
using web browser ˿ Device supports connecting up to six SmartSensors to the controller, providing up to 64 detector channels via SDLC communications
Ordering information Click 656 102-0451
Accessories 102-0462 – Click 656 3U Mounting Shelf 102-0531 – U-mount Rail and Screws 310-0411 – SDLC Cable 310-0413 – SDLC Y Cable 102-0449 – 4-port SDLC Hub
Contact us 801.734.7200 sales@wavetronix.com www.wavetronix.com
NEMA TS2-2003 testing ˿ Complies with the applicable standards stated in the NEMA
TS2-2003 Standard ˿ Test results available for each of the following tests:
| ̀ Shock pulses of 10 g, 11 ms half sine wave |
| ̀ Vibration of 0.5 Grms up to 30 Hz |
| ̀ 300 V positive/negative pulses applied at one pulse per |
second at minimum and maximum AC supply voltage
| ̀ Stored at -49ºF (-45ºC) for 24 hours |
| ̀ Stored at 185ºF (85ºC) for 24 hours |
| ̀ Operation at -29.2ºF (-34ºC) and 89 VAC |
| ̀ Operation at -29.2ºF (-34ºC) and 135 VAC |
| ̀ Operation at 165.2ºF (74ºC) and 135 VAC |
| ̀ Operation at 165.2ºF (74ºC) and 89 VAC |
FCC testing ˿ FCC-compliant
Testing ˿ Passes manufacturer’s test before shipping
Surge immunity
| ˿ Surge immunity sensor ports: IEC/EN 61000-4-5 level 4 |
| ˿ Surge immunity AC input: IEC/EN 61000-4-5 level 3 |
Extended support ˿ Extended support options are available from Wavetronix;
contact a Wavetronix representative for more information
Warranty ˿ Two-year warranty against material and workmanship defect
Bid specifications
1.0 General. This item shall govern the purchase and installation of a cabinet interface device (CID) equivalent to the Wavetronix Click 656.
Test results and other documentation demonstrating performance and capabilities shall be provided.
2.0 Product description. The CID shall be a module that provides power and surge protection and that communicates with contact closure devices, ethernet, and controllers through SDLC. The CID shall be shipped with the AC power cord, Ethernet cable, and terminal blocks necessary for wiring it, as well as with an extra fuse.
3.0 Physical. The CID shall not exceed 6 lbs. (2.72 kg) in weight.
The CID shall not exceed 6.6 in. × 5.125 in. × 7.3 in. (16.8 cm x 13 cm x 18.5 cm) in its physical dimensions.
The CID shall operate in the temperature range of -29°F to 165°F (-34°C to 74°C) and in humidity up to 95% RH.
4.0 Mounting. The CID shall be either rack-mounted in a standard 19” rack or shelf-mounted.
5.0 Power. The power supply voltage of the CID shall be 100 to 240 VAC. Its AC frequency shall be 50–60 Hz and the maximum power shall be 112 W at 80ºC.
The CID’s sensor connectors shall output 24 VDC.
6.0 Connections and communication. The CID shall include the following connections for power and communication:
6.1 Power. The CID shall have an IEC AC input.
6.2 Terminal block connectors. The CID shall have six terminal block connectors for connecting to sensors. These connectors shall be for terminating cables that carry power and RS-485 communications to and from the sensors.
6.3 Data RJ-11 connectors. The CID shall have six RJ-11 jacks for sending detection data from sensors to contact closure devices such as rack cards via jumper cables. This data shall be sent via RS-485. These jacks shall make up the physical interface of a dedicated data bus.
6.4 Control connectors. The CID shall have six other communication ports. These ports shall make up the physical interface of a dedi-cated control bus and shall allow users to connect to the sensors and configure them.
| • | DB-9 port for communicating via RS-232 |
| • | Two RJ-11 jacks for communicating via RS-485 |
| • | USB micro-B connector |
| • | T-bus port for connecting to a T-bus |
6.5 Ethernet connector. The CID shall have an RJ-45 10/100 Ethernet port to allow connection to a local network.
6.6 SDLC port. The CID shall have an SDLC port for direct connection to a traffic controller.
7.0 Other features. The CID shall have the following other features:
7.1 LEDs. The CID shall have four multicolored LEDs with activity-indicating functions:
| • | An LED that indicates when the device has power |
| • | An LED that indicates if the device has been disabled by surges |
| • | An LED that indicates when data is being transmitted on the control bus |
| • | An LED that indicates when data is being received on the control bus. |
7.2 Data RJ-11 jack features. The four jacks that make up the physical interface of the data bus (and that each correspond to one sensor) shall have a switch for turning their corresponding sensor off and an LED that indicates when that sensor has power.
7.3 Power switch. The CID shall have a switch for turning power off for the entire device.
7.4 OLED panel with keypad. The CID shall have a OLED panel on the device with a keypad for device configuration.
7.5 Web interface. The CID shall have a web interface for device configuration, accessible through a web browser from a network-connected device.
7.6 Configuration. The CID configuration shall support connecting up to six detectors to the controller, providing up to 64 detector channels via SDLC communications.
8.0 NEMA TS2-2003 testing. The CID shall comply with the applicable standards stated in the NEMA TS2-2003 Standard. Test results shall be made available for each of the following tests:
| • | Shock pulses of 10g, 11 ms half sine wave |
| • | Vibration of 0.5 Grms up to 30 Hz |
| • | 300 V positive/negative pulses applied at one pulse per second at minimum and maximum AC supply voltage |
| • | Cold temperature storage at -49°F (-45°C) for 24 hours |
| • | High temperature storage at 185°F (85°C) for 24 hours |
| • | Low temp, low DC supply voltage at -29.2°F (-34°C) and 89 VAC |
| • | Low temp, high DC supply voltage at -29.2°F (-34°C) and 135 VAC |
| • | High temp, high DC supply voltage at 165.2°F (74°C) and 135 VAC |
| • | High temp, low DC supply voltage at 165.2°F (74°C) and 89 VAC |
9.0 FCC testing. The CID shall be FCC-compliant.�
10.0 Testing. Before shipping, each CID shall have passed a manufacturer’s test.
11.0 Surge immunity. The sensor ports of the CID shall conform to IEC/EN 61000-4-5 level 4 standards; the AC input of the CID shall con-form to IEC/EN 61000-4-5 level 3 standards.
12.0 Extended support. Extended support options shall be available. Contact the manufacturer’s representative for more information.