ESBD_444321_1754917564474_EXHIBIT XI Architectural Drawings.pdf

PDF 484 KB Posted

Attached to
Site Maintenance Projects Magoffin Home State Historic Site
Solicitation number
808-25-253325
Issued by
El Paso County, El Paso City, Texas

About this file

This document is an architectural drawing set for the Visitor Center Structural & Architectural Repairs project by the Texas Historical Commission, located at 1117 Magoffin Avenue in El Paso, Texas. The drawings specifically detail an enlarged restroom plans and elevations document (Sheet A411) for demolition and renovation work, focusing on bathroom spaces in rooms 107 (Women's) and 108 (Men's). The plans outline a comprehensive renovation strategy that involves carefully salvaging and reinstalling existing bathroom fixtures, including grab bars, toilet partitions, vanities, mirrors, and tile accent bands, while also addressing structural elements like temporary wood shoring and exterior wall modifications.

The project involves precise architectural restoration work, with detailed instructions for removing and reinstalling building elements while maintaining the historic integrity of the site. The drawings include specific notes on demolition procedures, restoration techniques, and repair methodologies for various materials including gypsum board, plaster, and mortar joints. The project appears to be funded by the Texas Historical Commission and is part of a broader preservation effort for the Magoffin Home State Historic Site, with the architectural work being performed by Treanor Design, a Dallas-based architectural firm. The project number is HP17066.2401.00, with a documented date of 03/05/2025, and includes provisions for careful material preservation and matching of existing architectural elements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REINSTALL

SALVAGED

GRAB BARS

REINSTALL

SALVAGED

TOILET PAPER

DISPENSER

SCALE:

WOMEN - 10703

3/8"=1'-0"

SCALE:

MEN - 10807

3/8"=1'-0"

SCALE:

WOMEN - 10706

3/8"=1'-0"

SCALE:

MEN - 10810

3/8"=1'-0"

SCALE:

WOMEN - 10705

3/8"=1'-0"

SCALE:

MEN - 10809

3/8"=1'-0"

SCALE:

WOMEN - 10704

3/8"=1'-0"

SCALE:

MEN - 10808

3/8"=1'-0"

TILE WAINSCOT,

ALIGN W/ EXIST.

TYP.

REINSTALL

SALVAGED

VANITY AND

PLASTIC

LAMINATE

COUNTERTOP

REINSTALL

SALVAGED

SURFACE

MOUNTED

MIRROR

REINSTALL

SALVAGED TOILET

PARTITION

TILE WAINSCOT, ALIGN

W/ EXIST., TYP.

REINSTALL SALVAGED

VANITY AND PLASTIC

LAMINATE

COUNTERTOP

REINSTALL SALVAGED

SURFACE MOUNTED

MIRROR

REINSTALL

SALVAGED TOILET;

FLUSH HANDLE ON

WIDE SIDE OF

ACCESSIBLE STALL

EXIST. URINAL

/A

/A

TILE LEDGE WITH

BULLNOSE

TILE BULLNOSE,

TYP.

TILE COVE BASE,

TYP.

TILE BULLNOSE, TYP.

TILE COVE BASE, TYP.

PROVIDE ADDITIONAL

BLOCKING IN WALL

THIS AREA

REINSTALL

SALVAGED TILE

ACCENT BAND,

ALIGN W/ EXIST.

REINSTALL SALVAGED

TILE ACCENT BAND,

ALIGN W/ EXIST.

EXIST. TOILET

EXIST. TILE

WAINSCOT, TYP.

EXIST. TILE

ACCENT BAND,

TYP.

REINSTALL

SALVAGED

TOILET; FLUSH

HANDLE ON WIDE

SIDE OF

ACCESSIBLE

STALL

EXIST. TILE

WAINSCOT AND

ACCENT BAND,

TYP.

EXIST. PAPER

TOWEL

DISPENSER AND

DISPOSAL

EXIST. TILE

WAINSCOT AND

ACCENT BAND,

TYP.

REINSTALL

SALVAGED VANITY

AND PLASTIC

LAMINATE

COUNTERTOP

TILE WAINSCOT,

ALIGN W/ EXIST., TYP.

TILE BULLNOSE, TYP.

TILE COVE

BASE, TYP.

REINSTALL

SALVAGED TILE

ACCENT BAND,

ALIGN W/ EXIST.

EXIST. PAPER

TOWEL

DISPENSER AND

DISPOSAL

REINSTALL

SALVAGED SOAP

DISPENSER AND

SURFACE MOUNTED

MIRROR

EXIST. TILE

WAINSCOT AND

ACCENT BAND,

TYP.

REINSTALL

SALVAGED VANITY

AND PLASTIC

LAMINATE

COUNTERTOP

TILE WAINSCOT,

TYP.

TILE BULLNOSE,

TYP.

TILE COVE

BASE, TYP.

REINSTALL

SALVAGED TILE

ACCENT BAND,

ALIGN W/

EXIST., TYP.

REINSTALL

SALVAGED

GRAB BARS

REINSTALL SALVAGED

TOILET PARTITION

REINSTALL

SALVAGED TOILET

PARTITION

REINSTALL

SALVAGED SOAP

DISPENSER AND

SURFACE

MOUNTED MIRROR

REINSTALL SALVAGED

SOAP DISPENSER

'-2

'-2

'-8

" T O

S

PO

U T

'-8

" T O

S

PO

U T

2'-0" 1'-0"

'-1

" T

O C

L

2'-0" 1'-0"

'-1

" T

O C

L

8"

'-8

'-8

3'-6" 4'-6"

REINSTALL

SALVAGED TOILET

PARTITION

SCALE:

ENLARGED DEMOLITION PLAN01

3/8"=1'-0"

MEN

WOMEN

ALCOVE

STORAGE

JANITOR/

EXIST.

F.D.

EXIST.

F.D.

REMOVE WOOD

WINDOW, FRAME, AND

INTERIOR WOOD

CASING AND SALVAGE

FOR REINSTALLATION IN

SAME LOCATION

REMOVE VANITY AND

COUNTERTOP AND

SALVAGE FOR

REINSTALLATION IN

SAME LOCATION, TYP.

REMOVE TOILET

PARTITIONS AND TOILET

ACCESSORIES AND

SALVAGE FOR

REINSTALLATION IN

SAME LOCATION, TYP.

REMOVE TOILET FIXTURE

AND SALVAGE FOR

REINSTALLATION IN

SAME LOCATION

REMOVE ACCENT TILE

BAND ON THE EXTERIOR

(WEST) SIDE OF

EXISTING WOOD

SHORING AND SALVAGE

FOR REINSTALLATION IN

SAME LOCATION; THEN

REMOVE PORTION OF

WALLS ON THE

EXTERIOR (WEST) SIDE

OF EXISTING WOOD

SHORING

EXIST. TEMPORARY WOOD

SHORING. ADD PLYWOOD

SHEATHING AND MOISTURE

BARRIER ON THE EXTERIOR

SIDE TO CREATE

WEATHERTIGHT ENCLOSURE;

TIE INTO FLOOR, CEILING

AND SIDE WALLS

PROTECT EXIST.

TOILET

PROTECT EXIST.

URINAL

TEMPORARY WOOD STUD

WALL WITH PLYWOOD

SHEATHING AND

MOISTURE BARRIER ON

THE EXTERIOR SIDE TO

CREATE WEATHERTIGHT

ENCLOSURE; TIE INTO

FLOOR, CEILING AND

ADJACENT WALLS

TEMPORARY WOOD STUD

WALL WITH PLYWOOD

SHEATHING AND

MOISTURE BARRIER ON

THE EXTERIOR SIDE TO

CREATE WEATHERTIGHT

ENCLOSURE; TIE INTO

FLOOR, CEILING AND

ADJACENT WALLS

REMOVE TOILET FIXTURE

AND SALVAGE FOR

REINSTALLATION IN

SAME LOCATION

RELOCATE TEMPORARY

SHORING IN WOMEN 107 TO

ALIGN WITH TEMPORARY

SHORING IN MEN 108, REF.

STRUCTURAL

SCALE:

ENLARGED FLOOR PLAN02

3/8"=1'-0"

MEN

WOMEN

STORAGE

JANITOR/

'-6

EQ

EQ

EQ

EQ 2

'-9

" E

XI

S T.

F.

V

10/A6.3

08/A6.3

/A

6.

/A

6.

04/A411

/A

06/A411

/A

ALCOVE

EXIST.

F.D.

EXIST.

F.D.

EXIST. TOILET

EXIST.

URINAL

REMOVE TEMPORARY

WOOD SHORING PRIOR TO

PERFORMING INTERIOR

WORK IDENTIFIED IN 02

THROUGH 10/A411

REINSTALL SALVAGED

TOILET ACCESSORIES,

INCLUDING GRAB BARS,

AND TOILET PAPER

DISPENSERS, TYP.

REINSTALL SALVAGED

TOILET FIXTURE

REINSTALL SALVAGED

COUNTERTOP AND

VANITY, REF. 02/A412,

INCLUDING MIRRORS,

SOAP DISPENSERS, TYP.

REINSTALL SALVAGED

TOILET PARTITIONS, TYP.

5'-1" EXIST. F.V. 5

'-1

" E

XI

S T.

F .V

5'-71

2" EXIST. F.V.

'-1

" E

XI

S T.

F .V

REINSTALL SALVAGED

TOILET FIXTURE

'-0

1 2

3'-8" EXIST. F.V.

6'-31 2" +/-

'-1

A2A1

A1

A1

A1

1'-6"

PLAN

NORTH Date:

Project No.:

Sheet Title:

Drawing No.:

VI

SI

TO

R

CE

NT

ER

ST

RU

CT

UR

AL

AR

CH

IT

EC

TU

RA

L R

EP

AI

RS

M

AG

OF

FI

N

AV

EN

UE

, E L

PA

SO

, T

EX

AS

R ev is io ns

R ev

D es cr ip tio n

D at e

TE

XA

S

HI

ST

OR

IC

AL

C

OM

M

IS

SI

ON

M

AG

OF

FI

N

HO

M

E

ST

AT

E

HI

ST

OR

IC

S

IT

E

HP17066.2401.00

03/05/2025

2554 Elm Street, Suite 200 Dallas, TX 75226 Office: 214.310.1018 www.Treanor.Design

AT

T S

XETE FO

SA

G

. JO

HNSTON

2 14 8 2

R

EG

IS

TE

RED ARCHITEC

T

ENLARGED RESTROOM

PLANS AND ELEVATIONS

A411

821 40

GENERAL NOTES DEMOLITION PLANS

1. REFER TO SHEET A001 FOR INTENDED SEQUENCE

OF WORK.

2. REFER TO SHEET A001 FOR GENERAL PROJECT

NOTES.

3. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL

DEMOLITION WORK, AND FOR WORK THAT MAY

REQUIRE DEMOLITION OF ARCHITECTURAL

ELEMENTS.

4. DURING DEMOLITION OPERATIONS, SALVAGE FOR

REUSE BUILDING ELEMENTS AND MATERIALS AS

INDICATED.

DEMOLITION LEGEND

ELEMENT TO BE REMOVED

EXISTING WALLS TO REMAIN

GENERAL NOTES FLOOR PLANS AND

INTERIOR ELEVATIONS

1. REFER TO SHEET A001 FOR INTENDED SEQUENCE

OF WORK.

2. REFER TO SHEET A001 FOR GENERAL PROJECT

NOTES.

3. SEAL AROUND PENETRATIONS LEFT IN EXTERIOR

WALLS, FLOORS AND ROOF.

4. RESTORE EXTERIOR MATERIALS, EXCEPT WHERE

NOTED OTHERWISE.

5. RESTORATION WORK SHOWN ON THE DRAWINGS

INDICATES THE APPROXIMATE LOCATION AND SIZE

OF SUCH WORK; SUCH WORK IS TO BE UNDERTAKEN

ONLY WHERE NEEDED. FINAL LOCATIONS MAY

VARY.

6. PATCH EXISTING MATERIALS TO MATCH

SURROUNDING FOLLOWING DEMOLITION.

7. CRACK REPAIR IN GYPSUM BOARD INCLUDES:

a. APPLICATION OF JOINT COMPOUND OVER THE

CRACK

b. FOR LARGER CRACKS, COVERING CRACK WITH

FIBERGLASS MESH TAPE AND APPLYING

ADDITIONAL JOINT COMPOUND TO COVER TAPE

c. SANDING TO MATCH ADJACENT SURFACES

d. PAINTING ENTIRE WALL/CEILING TO MATCH

EXISTING COLOR

e. ALTERNATE: PAINTING ENTIRE ROOM TO MATCH

EXISTING COLOR

8. CRACK REPAIR IN PLASTER INCLUDES:

a. FILLING VOIDS WITH PATCHING COMPOUND

b. FOR LARGER CRACKS, EMBEDDING TAPE IN

PATCHING COMPOUND AND APPLYING ADDITIONAL

COMPOUND TO COVER TAPE

c. FINISHING TO MATCH ADJACENT SURFACES

d. PAINTING ENTIRE WALL/CEILING TO MATCH

EXISTING COLOR

e. ALTERNATE: PAINTING ENTIRE ROOM TO MATCH

EXISTING COLOR

9. CRACK REPAIR IN MORTAR JOINTS INCLUDES:

a. ROUTING OUT DEFECTIVE MORTAR JOINTS

b. FILLING OF JOINTS WITH MORTAR TO MATCH

ADJACENT

c. TOOLING OF JOINTS TO MATCH PROFILE OF

ADJACENT MORTAR JOINTS

LEGEND

WALL OR PARTITION

EXISTING WALLS TO REMAIN

TEMPORARY WALL

WALL TYPEX

AS

I#

/1 8/

File details come from the government source that posted it. Updated .