About this file
This document details comprehensive specifications for Multi-Gas Detectors, outlining precise technical requirements for a sophisticated sensing device capable of measuring multiple gas types and environmental conditions. The specifications cover an extensive range of sensor capabilities, including Photoionization Detector (PID), lower explosive limit (LEL), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), and Gamma radiation detection. Key device features include field-replaceable sensors, a rechargeable Li-ion battery with approximately 18-hour runtime, a built-in pump with 250 cubic centimeter average flow rate, and operational functionality from -4°F to 122°F.
The multi-gas detector is designed with advanced technological capabilities, featuring a liquid crystal display with backlighting, continuous datalogging for up to 6 months, wireless transmission capabilities using 900 megahertz frequency, and compatibility with RAE systems' Dedicated Wireless Network. Additional notable specifications include an IP 65/67 dust and water resistance rating, a minimum one-year warranty, and compliance with MIL-STD-810F Department of Defense testing standards and International Society of Automation performance requirements. The device offers comprehensive gas concentration monitoring with real-time readings, short-term exposure limit tracking, and a wireless range of 656 feet, making it suitable for industrial, scientific, and safety-critical environmental monitoring applications.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Multi-Gas Detector Specifications Multi-Gas Detectors to include:
I. Sensors to measure, Photoionization Detector (PID), lower explosive limit (LEL), Carbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), and Gamma
A. Volatile Organic Compound 10.6 electron volts lamp parts per billion (ppb)– Range of 0 to 2,000 parts per million (ppm) with a resolution of 10 parts per billion
B. Catalytic lower explosive limit – Range from 0 to 100 percent lower explosive limit with a resolution of 1 percent lower explosive limit
C. Carbon monoxide – Range of 0 to 500 parts per million with resolutions of 1 part per million and Hydrogen sulfide - Range of 0 up to 200 parts per million with a resolution from 0.1 – combination sensor
D. Oxygen – Range of 0 to 30 percent volume with a resolution of 0.1 percent volume.
E. Gamma sensor – Range of 0 to 20,000 microREM per hour with a resolution of 1 micro-
Roentgen Equivalent Man(µREM) per hour
II. Field-Replaceable sensors
III. Rechargeable Li-ion Battery, Extended duration (approximately 18-hour runtime)
IV. Built-in pump, Average flow rate 250 cubic centimeters
V. Operating Temperature of negative 4 degrees to 122 degrees Fahrenheit (negative 20 degrees to 50 degrees Celsius)
VI. Dust and water resistance – ingress protection rating (IP) 65/IP 67 (when off) rating
VII. Minimum 1 year Warranty on parts and sensors
VIII. Display Capabilities
A. Liquid Crystal Display with backlighting B. Real-time reading of gas concentrations; PID measurement gas and correction factor;
battery status; datalogging on/off; wireless on/off and reception quality.
C. Short-term exposure limits (STEL), time-weighted average (TWA), peak, and minimum values
IX. Datalogging
A. Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7) B. User-configurable datalogging intervals (from 1 to 3,600 seconds)
X. Wireless capability
A. 900 megahertz B. Compatible with RAE systems Dedicated Wireless Network C. Industrial, Scientific, and Medical license free bands D. Wireless range of 656 feet (200 meters) E. Wireless data and alarm status transmission via built-in RF modem
XI. Performance Tests
A. MIL-STD-810F Department of Defense Testing Compliant B. International Society of Automation-12.13.01 Performance Requirements for
Combustible Gas Detectors Compliant