This document is Attachment A, a detailed specification for a Hydrogen Sulfide Analyzer, which appears to be part of a state or local government procurement opportunity. The specification outlines comprehensive technical requirements for a portable analyzer capable of detecting hydrogen sulfide in concentrations ranging from 3 parts per billion (ppb) to 10 parts per million (ppm), with high-precision measurement capabilities. The analyzer must have a resolution of 20 parts per trillion (ppt), offer multiple measurement modes (survey, manual, auto), provide onboard data logging for 20,000 samples, include a liquid crystal display screen, and feature digital and analog output options.

The analyzer specification includes additional critical requirements such as a lightweight design (not exceeding 5.4 pounds), a rechargeable battery with an 18-hour life that charges in 3 hours, and a hard carrying case for transport. The device must provide multiple data output methods, including USB connectivity to computers, printers, or flash drives, and an analog 4-20 milliamp current loop output. The specification also mandates a one-year warranty for parts and labor, and requires vendors to detail the cost of any additional accessories needed for equipment operation. These precise technical requirements suggest a specialized scientific or environmental monitoring procurement, likely for a government agency or research institution involved in environmental testing or industrial safety.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment A

Hydrogen Sulfide Analyzer Specification Hydrogen Sulfide Analyzer to include:

a. Detection range of 3 parts per billion(ppb) to 10 parts per million(ppm) with a resolution of 20 parts per trillion(ppt) dependent on range

b. Measures in ppm, ppb with accuracies:

i. Plus or minus 1 ppb at 5 ppb

ii. Plus or minus 3 ppb at 50 ppb

iii. Plus or minus 0.03 ppm at 0.5 ppm

iv. Plus or minus 0.3 ppm at 5.0 ppm

c. Response Time

i. Survey Mode: 12-27 seconds

ii. Manual Mode: 12-27 seconds

iii. Auto Mode: 12-53 seconds

d. Flow Rate of 150 Milliliters(mL)/min

e. Automatic date/time stamp

f. Ability to Autosample: 1, 2, 5, 10, 15, 30, 45, 60, 90, or 120 minutes

g. Onboard data logging – 20,000 samples

h. Liquid Crystal Display Screen

i. Output

i. Digital: Universal Serial Bus to personal computer, printer, or flash drive

ii. Analog: 4-20 Milliamps(mA) passive current loop; accurate to 0.3 percent of output

j. Not to exceed 5.4 pounds

k. Battery

i. Rechargeable battery

ii. 18 hour life

iii. charges in 3 hours

l. Hard carrying case for transport

m. Detail cost of any accessories needed to allow equipment to operate (if not included)

n. Warranty of 1 year for parts and labor

Attachment A