ESBD_378836_1730230933921_ADDENDUM #2 Belvin Hall.pdf

PDF 5 MB Posted

Attached to
Belvin Buchanan Hall Renovation
Solicitation number
753-25-95900
Issued by
Van Zandt County, Houston City, Texas

About this file

This document is an Addendum to a Request for Proposals (RFP) posted by Sam Houston State University for the Belvin Buchanan Hall Renovation project, Project No. 753-25-95900. The scope of work includes the replacement of cast iron piping, a new roof, and interior finish upgrades to the Belvin Buchanan Hall on the Sam Houston State University campus in Huntsville, Texas. The RFP requires the submission of a Historically Underutilized Business (HUB) Subcontracting Plan, and the Owner will award the contract to the respondent offering the "best value" based on 50% pricing and 50% qualifications. The contract will be in the form of the Owner's Standard General Contractor Agreement, awarded as a lump-sum contract. Proposals are due by November 6, 2024, at 2:00 p.m. Central Time, and a mandatory pre-proposal conference is scheduled for October 16, 2024.

The document does not provide the exact award value, but it does state there is an estimated construction budget. There is no information included about any incumbent vendors or current contractors for this project. The Owner reserves the right to divide the project, reject any and all proposals, or temporarily or permanently abandon the project.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(i)

(ii)

REQUEST FOR PROPOSALS

FOR

GENERAL CONTRACTOR

FOR

SAM HOUSTON STATE UNIVERSITY

HUNTSVILLE, TEXAS

Belvin Buchanan Hall Renovation

RFP No.:

753-25-95900

Notice To All Respondents:

The following is Addendum No. 2 to the Request for Proposals (RFP) ESBD Posting No. 753-25-95900 which was posted on October 10, 2024

Prepared By:

Chuck Jones

Director, Facilities Planning and Construction

Sam Houston State University

2424 S. Sam Houston Ave.

Addendum No. 2 Issued October 29, 2024

I. Attachments:

a. Questions and Responses

-END OF ADDENDUM NO. 2 -

308 N. Bryan Ave., Bryan TX 77803 | www.arkitex.com | 979.821.2635

October 25, 2024

Questions/Responses Renovation of SHSU Belvin Buchanan Hall Project 24008, SHSU RFP #753-25-95900

Notice to all bidders:

This Addendum forms a part of the Contract Documents and modifies the Specifications and Drawings dated October 02, 2024, to the extent noted hereinafter. All parties of interest shall take careful note of this Addendum so that proper allowance is made in all computations, estimates and contracts and so that all trades affected are fully advised in the performance of work that will be required by them.

General:

1. Architectural sheets note the locations of some but not all electrical panels. Contractors shall refer to the electrical drawings for all electrical work and what is existing, new, or provided/installed by others.

Bidder Questions:

1. Question: Is Concession G48 a part of Project? Plans show 4 Lights in that room.

Response: Yes, it’s part of the project. The existing ceiling and lighting will be removed to accommodate the new plumbing installation, and new ceiling and lighting will be installed afterward. Also, "N.I.C" will be removed from the room labels at G48.

2. Question: Sheet E1.1 Corridor 126 Shows 3 Type A fixtures what do they go to?

Response: The existing ceiling and lighting will be removed to accommodate the new ductwork installation, and new ceiling and lighting will be installed afterward. New lights will tie into the existing lighting circuit. For the latest layout of those 3 fixtures refer to sheet A8.2.

3. Question: Sheet E1.1 Rooms 139, 140, 144 & 144A part of Alternate 6.2.2.2?

Response: All work associated with Bathroom 144A is part of the Base Bid. However, Rooms 139, 140, 142, and 144 together form Apartment 142 on the first floor, and this is part of Alternate 6.2.2.2.

4. Question: Sheet E1.2 Rooms 244, 246,249 & 249A Part of Base Bid or Alternate 6.2.2.2?

Response: All work associated with Bathroom 249A is part of the Base Bid. However, room 244, laundry closet, rooms 246 and 249 together form Apartment 246 on the second floor, and this is part of Alternate 6.2.2.2.

5. Question: Sheet E1.2 Corridor 226 shows 3 Type B Fixtures What do they go to?

Response: The existing ceiling and lighting will be removed to accommodate the new ductwork installation, and new ceiling and lighting will be installed afterward. New lights will tie into the existing lighting circuit.

6. Question: Is room 346A part of Alternate 6.2.2.2 or part of Base Bid?

Response: All work associated with Bathroom 346A is part of the Base Bid. However, room 342, laundry closet, rooms 344 and 346 together form Apartment 344 on the third floor, and this is part of Alternate 6.2.2.2.

7. Question: The Plans call for us to install conduit on the 3rd floor and penetrate exterior wall to feed power to flood lights.

How do we get conduit across the Hard Lid Ceilings to these locations?

Response: Penetrate roof in accessible area and run conduit on roof, see RFI below for further detail.

http://www.arkitex.com/

308 N. Bryan Ave., Bryan TX 77803 | www.arkitex.com | 979.821.2635

8. Question: Would be permissible to run conduit across the roof to feed these lights?

Response: Yes, conduit to be rigid with insulated throat compression fittings. Conduit to be supported by rubber roof pillow blocks.

9. Question: Which Rooms are to be provided with Audible / Visual doorbell system? All floors but 2nd have 2 rooms 2nd has 1 room?

Response: Reference sheets A2.1 through A2.4 for rooms noted as (Hearing Impaired) or (Mobility and Hearing Impaired)

10. Question: Do we use Wiremold or EMT Conduit for the surface raceways?

Response: Use EMT Conduit.

11. Question: Fixtures Type B1 and A1 is not shown on Fixture Schedule What Type are they?

Response: For fixtures with a “1” suffix, provide a flanged fixture for mounting in a gyp. board ceiling. Please refer to note 8 at the bottom of the light fixture schedule.

12. Question: CT-1 is Glazed subway tile. They cannot be installed on the floor. What is correct tile specification for wall and floor location?

Response: Please refer to specification section 093013-3.6: ceramic tile CT-1 is designated for the walls, while ceramic tile CT-2 is specified for the flooring. See attached updated finish schedule in sheet A5.1.

13. Question: What base is CT-2 per room finish schedule?

Response: Please refer to the updated finish schedule 1/A5.1 attached to this addendum. Base tile CT-1 should be specified for the rooms as listed in the schedule.

14. Question: What to install at the top of the wainscot? Schluter trim or bullnose (if available)?

Response: Please refer to specification section 093013 – 2.4.c, d, e, f, g. Bullnose is at the top of the wainscot.

15. Question: Any water proofing / crack isolation required?

Response: Waterproofing or crack isolation is not required.

16. Question: Is this correct material for LVT?

Response: Yes, the LVT material is specified in section 096519-2.2 of the specifications.

17. Question: Is this correct material description for B-1 wall base?

Response: Yes, the B-1 wall base material is specified in section 096513 -2.1 of the specifications.

18. Question: During the walkthrough, it was noted that there is a recess in the cooler slab that would need to be filled after the cooler is removed. However, upon reviewing the building’s existing plans, we could not find any mention of a recess, only a reference to a trench beneath the cooler. (See attached plan) Could you please clarify?

Response: It has been confirmed that the cooler/freezers do not recess into the slab. The floor insulating panels sit on top of the slab.

19. Question: Additionally, after reviewing the RFD, alternate 6.2.2.1 references” the flooring in the corridors or stairwells”. Could you confirm whether the stairwell flooring is included in the scope as well?

Response: The alternate does not include flooring in the stairwells.

20. Question: Should the bathrooms in the apartments be included in the base bid or part of the alternate?

Response: The bathroom scope for the apartments shall be included in the base bid.

21. Question: The electrical A&E guidelines call for compression fittings on EMT, can we use set screw?

Response: Steel set screw fittings are allowed on EMT in conditioned spaces. Die-cast set screw fittings are not allowed.

Electrical and Plumbing:

See attached description and reissued sheets for revisions to electrical and plumbing documents.

http://www.arkitex.com/

S H

S U

B el vi n

H al l B el vi n B uc ha na n

H al l, 7t h

S t, H un ts vi lle T

X

Revisions Number Date

PRELIMINARY

INTERIM REVIEW ONLY

Document is not complete and may not be used for regulatory approval, permit, or construction.

Architect: Eva Read-Warden Registration No: 15353 Date: 10/24/24

A5.1

R en ov at io n of

Project 24008 24 October, 2024

SCHEDULES

Revision#1 10/25/2024

ROOM NO.

101A 102A 105A 106A 109A 110A 113A 114A 117A

119A

121A

128A

129A

134T

141A

144A

201A 202A 205A 206A 209A 210A 213A 214A 219A

224A

229A 230A 233A 234A 239A 240A

245A

249A 301A 302A 305A 306A 309A 310A 313A 314A 317A

323A

328A 329A 332A 333A 338A 339A

345A

346A

G00C4 G1A G2A G5A G6

G8A G9A

G12A G13A G17A G19A G25 G26 G29

G29C1 G31 G36

G36A

ROOM NAME

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

ADA ROOM

BATH

LAUNDRY

ADA ROOM

BATH

CORRIDOR

CORRIDOR

BATH

ADA ROOM

BATH

LOBBY

RESTROOM

LOUNGE

OFFICE

OFFICE

ROOM

KITCHEN

ADA ROOM

BATH

APT.

ADA ROOM

ROOM

BATH

VESTIBULE

CORRIDOR

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

LAUNDRY

BATH

CORRIDOR

CORRIDOR

BATH

BATH

BATH

BATH

BATH

BATH

KITCHEN/LAUNDRY

BATH

APT.

VESTIBULE

ROOM

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

BATH

LAUNDRY

BATH

CORRIDOR

CORRIDOR

BATH

BATH

BATH

BATH

BATH

BATH

KITCHEN/LAUNDRY

APT.

BATH

ROOM

BATH

VESTIBULE

CORRIDOR

BATH

BATH

BATH

NEW LAUNDRY

BATH

BATH

BATH

BATH

BATH

BATH

CORRIDOR

CORRIDOR

OFFICES

CORRIDOR

NEW CLASSROOM

ROOM

NEW OFFICE

WALL

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

PT-1

CT-1,PT-1

Existing

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

Existing

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

PT-1

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

Existing

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

CT-1,PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

PT-1

FLOOR

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

CT-2

LVT-1

LVT-1

CT-2

LVT-1

LVT-1

CT-2

LVT-1

CT-2

LVT-1

CT-2

LVT-1

LVT-1

LVT-1

LVT-1

LVT-1

LVT-1

CT-2

LVT-1

LVT-1

LVT-1

CT-2

LVT-1

LVT-1

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

CT-2

LVT-1

LVT-1

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

CT-2

LVT-1

LVT-1

LVT-1

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

CT-2

LVT-1

LVT-1

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

LVT-1

CT-2

LVT-1

CT-2

LVT-1

LVT-1

CT-2

CT-2

CT-2

LVT-1

CT-2

CT-2

CT-2

CT-2

CT-2

CT-2

LVT-1

LVT-1

Existing

LVT-1

LVT-1

LVT-1

LVT-1

BASE

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1

CT-1

B-1 B-1

CT-1

B-1 B-1

CT-1

B-1

CT-1

Ptd. Exist Base

CT-1

Ptd. Exist Base

B-1 B-1 B-1 B-1 B-1

CT-1

B-1 B-1 B-1

CT-1

B-1 B-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1

CT-1

B-1 B-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1

CT-1

B-1 B-1 B-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1

CT-1

B-1 B-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1 B-1

CT-1

B-1

CT-1

B-1 B-1

CT-1

CT-1

CT-1

B-1

CT-1

CT-1

CT-1

CT-1

CT-1

CT-1

B-1 B-1 B-1 B-1 B-1 B-1 B-1

CEILING

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Existing

Ptd. Gyp.

Ptd. Gyp./Existing ACT

Existing Ptd. Gyp.

Existing Existing

Ptd. Gyp.

Existing

Ptd. Gyp.

ACT-1

ACT-1

Ptd. Gyp.

Existing Existing

ACT-1

ACT-1

Existing Ptd. Gyp.

ACT-1

Existing

ACT-1

Ptd. Gyp.

Existing Existing

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Existing Existing

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

ACT-1

Ptd. Gyp.

ACT-1

Existing

ACT-1

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Existing Existing

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

ACT-1

ACT-1

Ptd. Gyp.

ACT-1

Ptd. Gyp.

Existing

ACT-1

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Ptd. Gyp.

Existing Existing Existing Existing

ACT-1

ACT-1

ACT-1

REMARKS

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF Semi-gloss paint

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF

CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF

WIDTH HEIGHTTYPE NOTESDOOR # FRAME HEAD JAMB

3'-0" 7'-0"

SIGNAGE

Type H - 4/A5.1

HARDWARE SET

7'-0" 2

A

3'-0"

3'-0" 7'-0" 7'-0"

6'-8"3'-0"

3'-0" 6'-8" 1

3'-0" 1

Pocket Door

6'-0" 7'-0" 3'-0" 7'-0" 3'-0" 7'-0"

7'-0"3'-0" 7'-0"3'-0"

3'-0" 7'-0" 2 7'-0" 13'-0"

7'-0"

3'-0"

7'-0"3'-0"

7'-0" EXIST.3'-0"

15'-0" Double door 2'-8"

3'-0"

2'-8"

2'-8"

TYPE B

Wood door

A A A

A B A A B

B

B

EXIST.

A A

B B A

3'-0" 7'-0" 2C

T

TYPE C

Hollow metal door with 1" insulated, low-E clear glass

6'-8" 6'-8"

6'-8"

6'-8" 6'-8"

6'-8" 13'-0"B

6'-8" 12'-0"B

6'-8"3'-0"A

6'-8" 13'-0"B

6'-8" 12'-0" 6'-8" 12'-8"

Double door

3'-0" 7'-0" 2D

TYPE D

Hollow metal door with 1" insulated

Pocket Door

B B

B B

B B

3'-0" 7'-0"A 2

TYPE A

Painted wood 20min fire-rated door

Provide 1" door undercut

Provide 1" door undercut

Provide 1" door undercut Existing door and frame

Provide 1" door undercut

Provide 1" door undercut

Provide 1" door undercut

6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1

6/A5.1-sim 5/A5.1-sim 6/A5.1 5/A5.1

6/A5.1 5/A5.1 6/A5.1 5/A5.1

6/A5.1 5/A5.1 6/A5.1 5/A5.1

6/A5.1 5/A5.1

6/A5.1 5/A5.1

8/A5.1 7/A5.1

8/A5.1 7/A5.1

8/A5.1 7/A5.1

8/A5.1 7/A5.1

EXIST. EXIST.

8/A5.1 7/A5.1 8/A5.1 7/A5.1

8/A5.1 7/A5.1 8/A5.1 7/A5.1

8/A5.1 7/A5.1 8/A5.1 7/A5.1 8/A5.1 7/A5.1

8/A5.1 7/A5.1

8/A5.1 7/A5.1

Type C.1- 4/A5.1

7'-0"3'-0" EXIST.EXIST. Existing door and frameEXIST. EXIST.

7'-0"3'-0" EXIST.EXIST. Existing door and frameEXIST. EXIST.

7'-0"3'-0" 1B Provide 1" door undercut8/A5.1 7/A5.1

EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.6'-8"

EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.6'-8"

7'-0" EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.

Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1

Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type A.1 - 4/A5.1

Type A.1 - 4/A5.1 Type B.3 - 4/A5.1

Type A.1 - 4/A5.1

Type A.1 - 4/A5.1

Type A.1 - 4/A5.1

Type C.1- 4/A5.1

Type A.1 - 4/A5.1

Type A.1 - 4/A5.1

Type B.3 - 4/A5.1

Type B.3 - 4/A5.1

8/A5.1 7/A5.1

8/A5.1 7/A5.1

G6

139A

141A

G31

GC4A

GC4B

119B 119A

121A 121B

123B

129B 131A

139B

G36A

141B 141C 143A 143B 143C

G36B

G26

123A

129A

131B

6"

6"

6"

6"

3' -4

0'-0" finished floor

CL

NOTE

1. "T" denotes tempered glass.

2 Typical Hollow Metal1 Typical wood

Braille type II

5/8" letter size, verify font style w/ Owner

3/4" letter size, verify font style w/ Owner

48" A.F.F.

TYPE H

(Restroom signs)

TYPE C.1

(Office ID signs)

Braille type II

5/8" letter size, verify font style w/ Owner

3/4" letter size, verify font style w/ Owner

48" A.F.F.

TYPE B.1

(Informational signs)

5/8" letter size, verify font style w/ Owner

48" A.F.F.

TYPE B.3

(Room ID signs)

5/8" letter size, verify font style w/ Owner

48" A.F.F.

Braille type II

Changeable message

NOTE:

-Verify all sign location, text, and style with the Owner.

-Mount wall signs 9" apart from center of the sign to door jambs, typical.

- Provide matching opaque backing at opposite side of glass-where signs are mounted on glass doors or sidelites.

-Contractor shall be responsible for submitting a sign schedule from sign manufacturer to the Owner for verification prior to start of manufacturing process.

-Provide manufacturer's full range color/finish for Architect's selection.

-Replace all existing room and way finding signage per SHSU sign standards.

TYPE A.1

(ADA Room ID signs)

5/8" letter size, verify font style w/ Owner

48" A.F.F.

Braille type II Braille type IIMolly Jones

OFFICE

1/

4" 6"

1/4" 6" 1/4"

1/ 4"

6"

6 1/2" 1/4" 6" 1/4"

1/ 4"

1" 1/

4"

1/ 4"

1/ 4"

1/ 4"

6"

6" 1/4" 5 1/2" 1/4"

2" 1/

4" 1/

4" 2"

6"

8"

1/4" 7 1/2" 1/4"

1/ 4"

1/

2"

3"

6"

1/ 4"

1/

2" 1/

4"

1/4" 5 1/2"

1/4"

1/ 4"

EXIT

ONLY

STORAGE

Jamp anchor clips,

(3) per jamb

Scheduled hollow metal frame and door

Double nested studs

Scheduled partition

2" 3/

8" Sc he du le d op en in g

Face of wall where occurs

Scheduled hollow metal frame and door

Box beam

Scheduled partition

2" Sc he du le d op en in g

Scheduled door

Double nested studs

Scheduled partition

Wood door frame to match existing

2" S ch ed ul ed op en in g

Box beam

Scheduled partition

Scheduled door

Wood door frame to match existing

2" S ch ed ul ed op en in g

Scheduled aluminum frame and glass

Sealant and backer rod, both sides Shim

Continuous wood blocking

Scheduled opening

Existing wall assembly

2"

3/8"

Face of stud, typical

Sc he du le d op en in g

2"

3/ 8"

Shim

Continuous wood blocking and shim

Scheduled aluminum frame and glass. Door at sim.

Sealant and backer rod both sides

Existing exterior wall assembly

New boring though existing masonry wall; verify size with Plumbing

Masonry anchors

Flange

Nozzle

Sealant

Thread adapter/piping;

refer to Plumbing

New stainless steel thru-wall sleeve;

seal at face of wall

1 FINISH SCHEDULE2 DOOR SCHEDULE & TYPE

Scale: 1/4" = 1'-0"3 FRAME TYPE

Scale: 3" = 1'-0"4 SHSU SINAGE Refer to 2/A5.1

Scale: 3" = 1'-0"5 HOLLOW METAL DOOR JAMB Refer to 1/A2.1

Scale: 3" = 1'-0"6 HOLLOW METAL DOOR HEAD Refer to 1/A2.1

Scale: 3" = 1'-0"7 WOOD DOOR JAMB Refer to 1/A2.1

Scale: 3" = 1'-0"8 WOOD DOOR HEAD Refer to 1/A2.1

Scale: 3" = 1'-0"9 STOREFRONT JAMB Refer to 1/A2.1

Scale: 3" = 1'-0"10STOREFRONT HEAD Refer to 1/A2.1

Scale: 3" = 1'-0"11DOWNSPOUT NOZZLE DETAIL Refer to 1/A2.2

Note:

- All doors listed are new unless otherwise noted.

Note:

- Not all rooms appear on finish schedule. However, all rooms within Belvin Buchanan Hall are to be painted within the scope of this project..

-All paint at restrooms and bathrooms to be semi-gloss.

T:\230928\Construction Admin\Addenda\Addendum No. 001.docx

300 West 26th Street, Bryan, Texas 77803

P: 979.341.8181 | TBPE No. F-9357

Addendum No. 001

Project: SHSU Belvin Hall

Project No. 230928

Date: 10/25/2024

This Addendum forms a part of the Contract Documents. This addendum modifies and supplements the Contract Documents as described herein for the afore referenced Project and includes:

• Two (2) page narrative

• Zero (0) attachment(s)

• Nineteen (19) revised drawing sheet(s)

Changes to Drawings

Electrical

1. Sheet ED1.0 – Electrical Demolition Plan – Ground Floor

a. Removed references to replacing panels under this contract scope.

2. Sheet ED1.1 – Electrical Demolition Plan – First Floor

a. Removed references to replacing panels under this contract scope.

3. Sheet ED1.2 – Electrical Demolition Plan – Second Floor

a. Removed references to replacing panels under this contract scope.

4. Sheet ED1.3 – Electrical Demolition Plan – Third Floor

a. Removed references to replacing panels under this contract scope.

5. Sheet ED4.1 – Belvin Power Riser Diagram - Demolition

a. This sheet has been deleted from the set. This scope will be completed under a separate contract.

6. Sheet ED4.2 – Buchanan Power Riser Diagram - Demolition

a. This sheet has been deleted from the set. This scope will be completed under a separate contract.

7. Sheet E1.0 – Electrical Lighting Plan – Ground Floor

a. Added General Plan Note.

8. Sheet E1.1 – Electrical Lighting Plan – First Floor

a. Redefined area of ceiling work to match Architect’s RCP.

b. Added General Plan Note.

9. Sheet E1.2 – Electrical Lighting Plan – Second Floor

a. Redefined area of ceiling work to match Architect’s RCP.

b. Added General Plan Note.

10. Sheet E1.3 – Electrical Lighting Plan – Third Floor

a. Added General Plan Note.

11. Sheet E2.0 – Electrical Power Plan – Ground Floor

a. Removed references to replacing panels under this contract scope.

b. Moved panel GLE to a new location.

12. Sheet E2.1 – Electrical Power Plan – First Floor

a. Removed references to replacing panels under this contract scope.

10/25/2024

Addendum No. 001 | Page 2 of 2

T:\230928\Construction Admin\Addenda\Addendum No. 001.docx

13. Sheet E2.2 – Electrical Power Plan – Second Floor

a. Removed references to replacing panels under this contract scope.

14. Sheet E2.3 – Electrical Power Plan – Third Floor

a. Removed references to replacing panels under this contract scope.

15. Sheet E4.1 – Belvin Power Riser Diagram – New Work

a. This sheet has been deleted from the set. This scope will be completed under a separate contract.

16. Sheet E4.2 – Buchanan Power Riser Diagram – New Work

a. This sheet has been deleted from the set. This scope will be completed under a separate contract.

17. Sheet E5.1 – Electrical Ground Floor Panel Schedules

a. Removed Switchboard MSB, Panel GLD and Panel GLF as there is no scope in them.

b. Updated Panel GLE to identify circuits in this project scope.

18. Sheet E5.2 – Electrical Ground Floor Panel Schedules

a. Removed Panel GLJ and Panel GLK as there is no scope in them.

b. Updated Panel GLG and Panel GLH to identify circuits in this project scope.

19. Sheet E5.3 – Electrical First Floor Panel Schedules

a. Removed Panel 1LA and Panel 1LC as there is no scope in them.

b. Updated Panel 1LB and Panel L1A to identify circuits in this project scope.

20. Sheet E5.4 – Electrical Second Floor Panel Schedules

a. Removed Panel 2LA and Panel 2LC as there is no scope in them.

b. Updated Panel 2LB and Panel L2A to identify circuits in this project scope.

21. Sheet E5.5 – Electrical Third Floor Panel Schedules

a. Removed Panel 3LA as there is no scope in this panel.

b. Updated Panel 3LB, Panel L3A and Panel 3LC to identify circuits in this project scope.

Plumbing

1. Sheet P0.0 – Plumbing Symbols and Abbreviations

a. Added note that site investigation to locate the existing storm lines to Civil is to be done by the contractor as part of the scope of this project.

2. Sheet P1.0 – Plumbing Plan – Ground Floor

a. Added note that site investigation to locate the existing storm lines to Civil is to be done by the contractor as part of the scope of this project.

COVERED

CONCRETE WALK

CONCRETE

WALK WAY

UP

DN

DN

UP

DN

DN

MECH

G00U4

CORRIDOR

G29C1

OFFICES

G29

RESTROOM

N.I.C.

G39T1

JAN

N.I.C.

G38J1

LOADING DOCK

N.I.C.

G38J1

DRESSING

N.I.C.

G43A

STORAGE

N.I.C.

G58A

COLLABORATION STUDIO

N.I.C.

G58

STAGE

N.I.C.

G43

THEATRE

N.I.C.

G42

CORRIDOR

N.I.C.

G00C3

MECH

G00U3

STORAGE

G31

G6

CORRIDOR

G26

MECH

G00U2

C O

R R

ID

O

R G

N.I.C.

G23

F

MECH

G00U1

STAIRS

N.I.C.

G27

MECHANICAL

G00U3

ROOM

G14

ROOM

G12

ROOM

G10

ROOM

G8

RESIDENT ADVISOR

G2

RESIDENT ADVISOR

G1

ROOM

G3

ROOM

G5

ROOM

G7

ROOM

G9

ROOM

G11

ROOM

G13

ROOM

G15

ROOM

G17

ROOM

G19

ROOM

G21

STAIRS

G0

JAN

G6J

MECH

G00U3

VEST

N.I.C.

100V1

WOMEN'S RR

G45W1

MEN'S RR

G44M1

VEST

N.I.C.

G00V2

LOUNGE

N.I.C.

G46

CONCESSION STORAGE

N.I.C.

G47

CONCESSION

N.I.C.

G48

VEST

N.I.C.

G00V3

FOYER

N.I.C.

G00L1

LOBBY

N.I.C.

G49

RECEPTION DESK

N.I.C.

G50

GALLERY

N.I.C.

G51

LOUNGE

N.I.C.

G52

REHEARSAL STUDIO

N.I.C.

G57

VAE ACOUSTIC STUDIO

N.I.C.

G53

CORRIDOR

N.I.C.

G00C3

ISOLATION STUDIO

N.I.C.

G54

ISOLATION STUDIO

N.I.C.

G55

ISOLATION STUDIO

N.I.C.

G56

STAIR TO NO WHERE

N.I.C.

G59

ELEV

N.I.C.

G00E1

C O

R R

ID

O

R G

C

MECHANICAL

G00U4

MECHANICAL

G00U5

ELEV. EQUIP. ROOM

N.I.C.

G00U6

MAINT / STORAGE

N.I.C.

G62

MUSIC STUDIO

N.I.C.

G61

DIGITAL STUDIO

N.I.C.

G60

CORRIDOR

N.I.C.

G00C1

FREEZER

G36A1

DRY STORAGE

G36A

COOLER 2

G36B

COOLER 1

G36C

OFFICE

G29A

OFFICE

G29B

OFFICE

G29C

CONTROL BOOTH

N.I.C.

G41

SD

SD

SD

SD

J J J

F

F

F

ELECTRICAL DEMOLITION

PLAN - GROUND FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

ED1.0

ELECTRICAL DEMOLITION PLAN - GROUND FLOOR1

1/8" = 1'0"

KEYED PLAN NOTES:

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

NOT USED.

EXISTING COOLERS/FREEZERS TO BE REMOVED. REMOVE ASSOCIATED

WIRING AND CONDUIT BACK TO PANELS.

COOLER CONDENSING UNIT TO BE REMOVED. REMOVE ALL ASSOCIATED

WIRING/CONDUIT BACK TO PANELS.

EXISTING PANEL GLA TO REMAIN.

EXISTING EQUIPMENT DISCONNECT TO BE REMOVED. REMOVE ALL

ASSOCIATED WIRING AND CONDUIT.

EXISTING SMOKE DETECTOR TO BE RELOCATED. REFER TO SHEET E2.0 FOR

NEW LOCATION.

EXISTING FIRE ALARM AV DEVICE TO BE RELOCATED. REFER TO SHEET E2.0

FOR NEW LOCATION.

EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS

SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL

BE REPLACED FOR INSTALLATION OF NEW DEVICES.

EXISTING KITCHEN HOOD/LIGHTING TO REMAIN.

ED1.0

30'20'10'0

SCALE: 1/8"=1'-0"

5'

GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)

1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES

2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE

ON ADJACENT SURFACES AND AREAS.

3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO

REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.

4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.

5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING

TRANSPORT AND STORAGE.

6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.

PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.

7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR

ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.

8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.

GENERAL NOTE

ALL EQUIPMENT/DEVICES

SHOWN SHALL BE REMOVED,

UNLESS OTHERWISE NOTED.

ADDENDUM #1 10/25/241

DNUP

DN

DN

DNUP DNUP

RESIDENT ADVISOR

ADA ROOM

ADA ROOM

ADA ROOM

RESTROOM

134T

LAUNDRY

120 STORAGE

139OFFICE

OFFICE

LOUNGE

LOBBY

ROOM

ROOM

JAN

125J

CORRIDOR

C O

R R

ID

O

R

ROOM

ROOM

MECH

MECH

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

RESIDENT ADVISOR

CORRIDOR

HALL STO

VESTIBULE

ROOM

ROOM

STAIRS

STAIRS

STAIRS

MECHANICAL

ELEV

ADA ROOM

ADA ROOM

F

SD

SD

SD SD

SD

SD

J

V

V

J

SD

11 11

12 12

15 16

16 16

16 16

F

F

F

ELECTRICAL DEMOLITION

PLAN - FIRST FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

ED1.1

ELECTRICAL DEMOLITION PLAN - FIRST FLOOR1

1/8" = 1'0"

ED1.1

KEYED PLAN NOTES:

NOT USED.

NOT USED.

NOT USED.

EXISTING FIRE ALARM CONTROL PANEL TO REMAIN.

NOT USED.

EXISTING FIREPLACE TO BE REMOVED. EXISTING FIREPLACE RECEPTACLE

TO REMAIN FOR CONNECTION TO NEW FIREPLACE. REFER TO SHEET E2.1.

EXISTING FIRE ALARM PULL STATION TO REMAIN.

EXISTING FIRE ALARM A/V DEVICE TO REMAIN.

EXISTING DRYER RECEPTACLE TO BE REMOVED. REMOVE ASSOCIATED

WIRING AND CONDUIT BACK TO PANEL.

EXISTING FIRE ALARM A/V DEVICE TO BE REMOVED AND REUSED. REFER

TO SHEET E2.1 FOR NEW LOCATION.

EXISTING VENDING MACHINE RECEPTACLE TO BE REMOVED. REMOVE TO

ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT SHALL REMAIN FOR

CONNECTION TO NEW VENDING MACHINE. REFER TO SHEET E2.1 FOR NEW

LOCATION.

EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO

SHEET E2.1 FOR NEW LOCATION.

EXISTING 3-WAY SWITCH TO BE REMOVED.

EXISTING LIGHT FIXTURE TO BE DEMOLISHED.

EXISTING FIRE ALARM VISUAL DEVICE TO BE REMOVED AND REUSED.

REFER TO SHEET E2.1 FOR NEW LOCATION.

EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS

SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL

BE REPLACED FOR INSTALLATION OF NEW DEVICES.

30'20'10'0

SCALE: 1/8"=1'-0"

5'

GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)

1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES

2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE

ON ADJACENT SURFACES AND AREAS.

3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO

REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.

4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.

5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING

TRANSPORT AND STORAGE.

6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.

PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.

7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR

ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.

8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.

GENERAL NOTE

ALL EQUIPMENT/DEVICES

SHOWN SHALL BE REMOVED,

UNLESS OTHERWISE NOTED.

ADDENDUM #1 10/25/241

DNUP DN UP

C ROOM

ROOM

LAUNDRY

225J

C O

R R

ID

O

R

CORRIDOR

VESTIBULE

STO

221A

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

STO

MECH

222U3

STO

ROOM

MECH

218U2

ROOM

217 ROOM

UTIL

215U1

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

RESIDENT ADVISOR

RESIDENT ADVISOR

MECH

236U6

MECH

235U5

STAIRS

N.I.C.

STAIRS

N.I.C.

STAIRS

N.I.C.

ELEV

N.I.C.

F F

SD

SD

SD

V

8 8

7 7

7 7

7 7

7 7

ELECTRICAL DEMOLITION

PLAN - SECOND FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

ED1.2

ELECTRICAL DEMOLITION PLAN - SECOND FLOOR1

1/8" = 1'0"

ED1.2

KEYED PLAN NOTES:

NOT USED.

NOT USED.

NOT USED.

NOT USED.

EXISTING DYER TO BE RELOCATED. REMOVE ASSOCIATED WIRING AND

CONDUIT TO ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT TO

REMAIN. REFER TO E2.2, KEYED NOTE 5.

EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO

SHEET E2.2 FOR NEW LOCATION.

EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS

SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL

BE REPLACED FOR INSTALLATION OF NEW DEVICES.

EXISTING FIRE ALARM DEVICE TO BE REPLACED WITH LOW FREQUENCY

HORN/STROBE DEVICE.

30'20'10'0

SCALE: 1/8"=1'-0"

5'

GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)

1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES

2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE

ON ADJACENT SURFACES AND AREAS.

3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO

REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.

4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.

5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING

TRANSPORT AND STORAGE.

6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.

PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.

7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR

ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.

8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.

GENERAL NOTE

ALL EQUIPMENT/DEVICES

SHOWN SHALL BE REMOVED,

UNLESS OTHERWISE NOTED.

ADDENDUM #1 10/25/241

DNDN

DN

ROOM

ROOM

344STORAGE

MECH

300U1

304J1 M

UTIL

315U2

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

STO

STO

ROOM

ROOM

ROOM

ROOM

315 ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

RESIDENT ADVISOR

RESIDENT ADVISOR

MECH

325J2

STAIRS

C O

R R

ID

O

R

STAIRS

STAIRS

STO

322U4

MECH

320U3 MECH

334U6

MECH

335U5

VESTIBULE

CORRIDOR

ELEV

LAUNDRY

a a a a a a a a a a a a a a a a a a

SD

a

SD

a a a a a SD

V

F F 7 7

8 8

66666

6 6

ED1.3

ELECTRICAL DEMOLITION

PLAN - THIRD FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

ELECTRICAL DEMOLITION PLAN - THIRD FLOOR

1/8" = 1'-0"

KEYED PLAN NOTES:

NOT USED.

NOT USED.

NOT USED.

NOT USED.

EXISTING DRYER TO BE RELOCATED. REMOVE ASSOCIATED WIRING AND

CONDUIT TO ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT TO

REMAIN. REFER TO E2.3, KEYED NOTE 5.

EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS

SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL

BE REPLACED FOR INSTALLATION OF NEW DEVICES.

EXISTING FIRE ALARM DEVICE TO BE REPLACED WITH LOW FREQUENCY

HORN/STROBE DEVICE.

EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO

SHEET E2.3 FOR NEW LOCATION.

30'20'10'0

SCALE: 1/8"=1'-0"

5'

GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)

1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES

2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE

ON ADJACENT SURFACES AND AREAS.

3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO

REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.

4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.

5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING

TRANSPORT AND STORAGE.

6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.

PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.

7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR

ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.

8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.

GENERAL NOTE

ALL EQUIPMENT/DEVICES

SHOWN SHALL BE REMOVED,

UNLESS OTHERWISE NOTED.

ADDENDUM #1 10/25/241

AutoCAD SHX Text

ED1.3

CONCRETE

WALK WAY

CORRIDOR

G26

ROOM

G10

ROOM

G8

MECHANICAL

G00U5

MECHANICAL

G00U4

BATH

G2A

BATH

G1A

BATH

G8A

BATH

G12A

BATH

G17A

BATH

G19A

MECH

G00U4

C O

R R

ID

O

R G

CORRIDOR

G29C1

OFFICES

G29

RESTROOM

N.I.C.

G39T1

JAN

N.I.C.

G38J1

LOADING DOCK

N.I.C.

G38J1

DRESSING

N.I.C.

G43A

STORAGE

N.I.C.

G58A

COLLABORATION STUDIO

N.I.C.

G58

STAGE

N.I.C.

G43

THEATRE

N.I.C.

G42

CORRIDOR

N.I.C.

G00C3

MECH

G00U3

NEW OFFICE

G36A

NEW CLASSROOM

G31

MECH

G00U2

N.I.C.

G23

F

MECH

G00U1

STAIRS

N.I.C.

G27

MECHANICAL

G00U3

ROOM

G14

ROOM

G12

NEW LAUNDRY

G6

RESIDENT ADVISOR

G2

RESIDENT ADVISOR

G1

ROOM

G3

ROOM

G5

ROOM

G9

ROOM

G11

ROOM

G13

ROOM

G15

ROOM

G17

ROOM (Hearing Impaired)

G19

ROOM (Hearing Impaired)

G21

STAIRS

N.I.C.

G0

MECH

G00U3

VEST

N.I.C.

100V1

WOMEN'S RR

G45W1

MEN'S RR

G44M1

VEST

N.I.C.

G00V2

LOUNGE

N.I.C.

G46

CONCESSION STORAGE

N.I.C.

G47

CONCESSION

N.I.C.

G48

VEST

N.I.C.

G00V3

FOYER

N.I.C.

G00L1

LOBBY

N.I.C.

G49

RECEPTION DESK

N.I.C.

G50

GALLERY

N.I.C.

G51

LOUNGE

N.I.C.

G52

REHEARSAL STUDIO

N.I.C.

G57

VAE ACOUSTIC STUDIO

N.I.C.

G53

CORRIDOR

N.I.C.

G00C3

ISOLATION STUDIO

N.I.C.

G54

ISOLATION STUDIO

N.I.C.

G55

ISOLATION STUDIO

N.I.C.

G56

STAIR TO NO WHERE

N.I.C.

G59

ELEV

N.I.C.

G00E1

C O

R R

ID

O

R G

C

ELEV. EQUIP. ROOM

N.I.C.

G00U6

MAINT / STORAGE

N.I.C.

G62

MUSIC STUDIO

N.I.C.

G61

DIGITAL STUDIO

N.I.C.

G60

CORRIDOR

N.I.C.

G00C1

ROOM

G36

C O

R R

ID

O

R G

C

OFFICE

G29A

CORRIDOR

G29C1

OFFICES

G29

OFFICE

G29B

OFFICE

G29C

CONTROL BOOTH

N.I.C.

G41

BATH

G5A

BATH

G9A

BATH

G13A

C CE

C

C C C C

C

C

C

C

C C

C

C

C

OS

LV

D

(2

F

F

F

F

F

F

F

F F

C C

OS

OS

LVD

OS

OSOS

OS OS

OS

OS

O S

CE

CE CE

X1

X1

LV

D

LV

X1

1 2

3 4 3 4

3 4

3 4

C

C C C C

CH

H H H H

H

C

C

C C

C C

ELECTRICAL LIGHTING

PLAN - GROUND FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

E1.0

ELECTRICAL LIGHTING PLAN - GROUND FLOOR1

1/8" = 1'0"

E1.0

KEYED PLAN NOTES:

NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING

JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW

SENSOR TO EXISTING SWITCHING CONDUCTORS.

INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX

ABOVE MIRROR AND THEN RECONNECT TO EXISTING

CONDUCTORS.

RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING

CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING

CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND

SWITCH AS SHOWN.

PROVIDE NEW CEILING MOUNTED OCCUPANCY SENSORS

AND DIMMING POWER PACKS TO SWITCH AS SHOWN.

LOCATION AND QUANTITY OF POWER PACKS NOT SHOWN.

EXISTING HOOD/LIGHTS TO REMAIN.

30'20'10'0

SCALE: 1/8"=1'-0"

5'

GENERAL NOTES LIGHTING SHEETS:

1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.

COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT

SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.

2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER

SHALL BE CONNECTED AS PER MANUFACTURER.

3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT

LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.

4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.

5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.

6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.

CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.

PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.

GENERAL PLAN NOTES:

1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW

VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.

2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY

RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A

NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR

MATCHING EXISTING FIELD CONDITIONS.

3. CONNECT NEW EXIT LIGHTS TO NEAREST UNSWITCHED

LIGHTING CIRCUIT.

4. IN AREAS WHERE EXISTING CEILINGS HAVE BEEN

REMOVED, REMOVE EXISTING LIGHT FIXTURES AND

REPLACE WITH NEW LIGHT FIXTURES. RECONNECT NEW

FIXTURES TO EXISTING LIGHTING CIRCUITS AND SWITCHING

SERVING SPACE.

ADDENDUM #11 10/25/24

W/D

W

W

W

DD

IM

F

CORRIDOR

C O

R R

ID

O

R

CORRIDOR

BATH

144A

BATH

141A

BATH

129A

BATH

121A�

BATH

119A

BATH

117A

BATH

114A

BATH

113A

BATH

106A

BATH

110A

BATH

109A

BATH

105A

BATH

102A

BATH

101A

JAN

125J

RESTROOM

134T

ROOM

ADA ROOM

ROOM

MECH

ADA ROOM

LAUNDRY

ADA ROOM

(Mobility and Hearing Impaired)

MECH

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

RESIDENT ADVISOR

RESIDENT ADVISOR

ROOM

OFFICE

OFFICE

LOUNGE

LOBBY

VESTIBULE

ROOM

ROOM

APT.

ROOM

STAIRS

N.I.C.

STAIRS

N.I.C.

STAIRS

N.I.C.

MECHANICAL

ELEV

ADA ROOM

ADA ROOM

BATH

128A

A

A A

AE

A

A

A

A A A

A

A A

A

A

A A

A A

F F

F F

F F

F

F

F

F

F

F F F

OS

OS

OS

D

D D

OS

OS

OS

OS

OS OS

B B B B

BB

B B

LV

D

OS

LVD

OS

O S

LVD

LV

D

AE

AE AE AE

BE

A

X2

X1

A A

LV

D

LV

LV

D

LV

D

LV

D

1 2

OSOS

OS

OS

OS

3 4

OS

OS

F

G G G

B B B

F

F

F

9 8

J

A1

B1

B1

A1A1

A1 B

B

A

A

A

A

B

ELECTRICAL LIGHTING

PLAN - FIRST FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

E1.1

ELECTRICAL LIGHTING PLAN - FIRST FLOOR1

1/8" = 1'0"

E1.130'20'10'0

SCALE: 1/8"=1'-0"

5'

KEYED PLAN NOTES:

NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING

JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW

SENSOR TO EXISTING SWITCHING CONDUCTORS.

INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX

ABOVE MIRROR AND THEN RECONNECT TO EXISTING

CONDUCTORS.

RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING

CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING

CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND

SWITCH AS SHOWN.

PROVIDE NEW CEILING MOUNTED OCCUPANCY SENSORS

AND DIMMING POWER PACKS TO SWITCH AS SHOWN.

LOCATION AND QUANTITY OF POWER PACKS NOT SHOWN.

ALL NEW LIGHT FIXTURES IN THIS ROOM TO BE SWITCHED

TOGETHER.

NEW SWITCH. CONNECT TO EXISTING FIXTURES IN ROOM.

GENERAL NOTES LIGHTING SHEETS:

1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.

COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT

SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.

2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER

SHALL BE CONNECTED AS PER MANUFACTURER.

3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT

LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.

4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.

5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.

6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.

CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.

PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.

GENERAL PLAN NOTES:

1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW

VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.

2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY

RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A

NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR

MATCHING EXISTING FIELD CONDITIONS.

3. CONNECT NEW EXIT LIGHTS TO NEAREST UNSWITCHED

LIGHTING CIRCUIT.

4. IN AREAS WHERE EXISTING CEILINGS HAVE BEEN

REMOVED, REMOVE EXISTING LIGHT FIXTURES AND

REPLACE WITH NEW LIGHT FIXTURES. RECONNECT NEW

FIXTURES TO EXISTING LIGHTING CIRCUITS AND SWITCHING

SERVING SPACE.

DISCONNECT AND REPLACE EXISTING LIGHT FIXTURE WITH

NEW TYPE J STRIP LIGHT WITH LENS. COORDINATE FIXTURE

LOCATION WITH EXISTING MECHANICAL EQUIPMENT, PIPING,

AND DUCTWORK.

SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.

CONNECT TO EXISTING CIRCUIT AND SWITCH AT DOOR AS

SHOWN.

SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.

CONNECT TO LIGHTING CIRCUIT IN ROOM AND SWITCH AT

DOOR AS SHOWN.

ADDENDUM #1 10/25/241

W

D D

W

W

W

TV

C O

R R

ID

O

R

CORRIDOR

VESTIBULE

BATH

249A

BATH

230A

BATH

234A

BATH

240A

BATH

245A

BATH

239A

BATH

233A

BATH

229A

BATH

224A

BATH

219A

BATH

205A

BATH

209A

BATH

213A BATH

214A

BATH

210A

BATH

206A

BATH

202A

BATH

201A

225J

KITCHEN

STO

221A

ROOM

ROOM

APT.

ROOM

ROOM

ROOM (Hearing Impaired)

ROOM

ROOM (Hearing Impaired)

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

STO

MECH

222U3

STO

LAUNDRY

ROOM

MECH

218U2

ROOM

217 ROOM

UTIL

215U1

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

ROOM

RESIDENT ADVISOR

RESIDENT ADVISOR

MECH

236U6

MECH

235U5

STAIRS

N.I.C.

STAIRS

N.I.C.

STAIRS

N.I.C.

ELEV

N.I.C.

W/D

F

2 2

1 1

1 1 1 1 1

B

F F

F F

F F

F F F F

F

F F F F F

OS OS

OSOS

OS

OS

OS

OS

OS

OS

OS

OS OS

OS OS

OS OS

B

B

B

B

B

O S

LV

D

LVD

LVD

OS

1 1

2 2

1 1

2 2

F

1 1 1 1

2 2 2

2 2 2 22

F

B B F

F

B

OS

4 4

B1

B1

B

B B

A

B B

B B

B

ELECTRICAL LIGHTING

PLAN - SECOND FLOOR

SH

SU

B el vi n

H al l Be lv in

B uc ha na n H al l, 7t h St

, H un ts vi lle T

X

Revisions Number Date

R en ov at io n of

Project 230928cz

OCTOBER 2, 2024

RANDY N. ROGERS

NOT FOR REGULATORY APPROVAL,

PERMIT OR CONSTRUCTION

P.E. REG. NO. 82143

REVIEW

10-25-24

PRELIMINARY

E1.2

ELECTRICAL LIGHTING PLAN - SECOND FLOOR1

1/8" = 1'0"

E1.230'20'10'0

SCALE: 1/8"=1'-0"

5'

KEYED PLAN NOTES:

NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING

JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW

SENSOR TO EXISTING SWITCHING CONDUCTORS.

INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX

ABOVE MIRROR AND THEN RECONNECT TO EXISTING

CONDUCTORS.

RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING

CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING

CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND

SWITCH AS SHOWN.

SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.

CONNECT TO EXISTING CIRCUIT AND SWITCH AT DOOR AS

SHOWN.

GENERAL NOTES LIGHTING SHEETS:

1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.

COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT

SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.

2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER

SHALL BE CONNECTED AS PER MANUFACTURER.

3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT

LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.

4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.

5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.

6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.

CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.

PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.

GENERAL PLAN NOTES:

1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW

VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.

2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY

RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A

NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR

MATCHING EXISTING FIELD CONDITIONS.

3. IN AREAS…