ESBD_378836_1730230933921_ADDENDUM #2 Belvin Hall.pdf
PDF 5 MB Posted
- Attached to
- Belvin Buchanan Hall Renovation
- Solicitation number
- 753-25-95900
- Issued by
- Van Zandt County, Houston City, Texas
About this file
This document is an Addendum to a Request for Proposals (RFP) posted by Sam Houston State University for the Belvin Buchanan Hall Renovation project, Project No. 753-25-95900. The scope of work includes the replacement of cast iron piping, a new roof, and interior finish upgrades to the Belvin Buchanan Hall on the Sam Houston State University campus in Huntsville, Texas. The RFP requires the submission of a Historically Underutilized Business (HUB) Subcontracting Plan, and the Owner will award the contract to the respondent offering the "best value" based on 50% pricing and 50% qualifications. The contract will be in the form of the Owner's Standard General Contractor Agreement, awarded as a lump-sum contract. Proposals are due by November 6, 2024, at 2:00 p.m. Central Time, and a mandatory pre-proposal conference is scheduled for October 16, 2024.
The document does not provide the exact award value, but it does state there is an estimated construction budget. There is no information included about any incumbent vendors or current contractors for this project. The Owner reserves the right to divide the project, reject any and all proposals, or temporarily or permanently abandon the project.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(i)
(ii)
REQUEST FOR PROPOSALS
FOR
GENERAL CONTRACTOR
FOR
SAM HOUSTON STATE UNIVERSITY
HUNTSVILLE, TEXAS
Belvin Buchanan Hall Renovation
RFP No.:
753-25-95900
Notice To All Respondents:
The following is Addendum No. 2 to the Request for Proposals (RFP) ESBD Posting No. 753-25-95900 which was posted on October 10, 2024
Prepared By:
Chuck Jones
Director, Facilities Planning and Construction
Sam Houston State University
2424 S. Sam Houston Ave.
Addendum No. 2 Issued October 29, 2024
I. Attachments:
a. Questions and Responses
-END OF ADDENDUM NO. 2 -
308 N. Bryan Ave., Bryan TX 77803 | www.arkitex.com | 979.821.2635
October 25, 2024
Questions/Responses Renovation of SHSU Belvin Buchanan Hall Project 24008, SHSU RFP #753-25-95900
Notice to all bidders:
This Addendum forms a part of the Contract Documents and modifies the Specifications and Drawings dated October 02, 2024, to the extent noted hereinafter. All parties of interest shall take careful note of this Addendum so that proper allowance is made in all computations, estimates and contracts and so that all trades affected are fully advised in the performance of work that will be required by them.
General:
1. Architectural sheets note the locations of some but not all electrical panels. Contractors shall refer to the electrical drawings for all electrical work and what is existing, new, or provided/installed by others.
Bidder Questions:
1. Question: Is Concession G48 a part of Project? Plans show 4 Lights in that room.
Response: Yes, it’s part of the project. The existing ceiling and lighting will be removed to accommodate the new plumbing installation, and new ceiling and lighting will be installed afterward. Also, "N.I.C" will be removed from the room labels at G48.
2. Question: Sheet E1.1 Corridor 126 Shows 3 Type A fixtures what do they go to?
Response: The existing ceiling and lighting will be removed to accommodate the new ductwork installation, and new ceiling and lighting will be installed afterward. New lights will tie into the existing lighting circuit. For the latest layout of those 3 fixtures refer to sheet A8.2.
3. Question: Sheet E1.1 Rooms 139, 140, 144 & 144A part of Alternate 6.2.2.2?
Response: All work associated with Bathroom 144A is part of the Base Bid. However, Rooms 139, 140, 142, and 144 together form Apartment 142 on the first floor, and this is part of Alternate 6.2.2.2.
4. Question: Sheet E1.2 Rooms 244, 246,249 & 249A Part of Base Bid or Alternate 6.2.2.2?
Response: All work associated with Bathroom 249A is part of the Base Bid. However, room 244, laundry closet, rooms 246 and 249 together form Apartment 246 on the second floor, and this is part of Alternate 6.2.2.2.
5. Question: Sheet E1.2 Corridor 226 shows 3 Type B Fixtures What do they go to?
Response: The existing ceiling and lighting will be removed to accommodate the new ductwork installation, and new ceiling and lighting will be installed afterward. New lights will tie into the existing lighting circuit.
6. Question: Is room 346A part of Alternate 6.2.2.2 or part of Base Bid?
Response: All work associated with Bathroom 346A is part of the Base Bid. However, room 342, laundry closet, rooms 344 and 346 together form Apartment 344 on the third floor, and this is part of Alternate 6.2.2.2.
7. Question: The Plans call for us to install conduit on the 3rd floor and penetrate exterior wall to feed power to flood lights.
How do we get conduit across the Hard Lid Ceilings to these locations?
Response: Penetrate roof in accessible area and run conduit on roof, see RFI below for further detail.
http://www.arkitex.com/
308 N. Bryan Ave., Bryan TX 77803 | www.arkitex.com | 979.821.2635
8. Question: Would be permissible to run conduit across the roof to feed these lights?
Response: Yes, conduit to be rigid with insulated throat compression fittings. Conduit to be supported by rubber roof pillow blocks.
9. Question: Which Rooms are to be provided with Audible / Visual doorbell system? All floors but 2nd have 2 rooms 2nd has 1 room?
Response: Reference sheets A2.1 through A2.4 for rooms noted as (Hearing Impaired) or (Mobility and Hearing Impaired)
10. Question: Do we use Wiremold or EMT Conduit for the surface raceways?
Response: Use EMT Conduit.
11. Question: Fixtures Type B1 and A1 is not shown on Fixture Schedule What Type are they?
Response: For fixtures with a “1” suffix, provide a flanged fixture for mounting in a gyp. board ceiling. Please refer to note 8 at the bottom of the light fixture schedule.
12. Question: CT-1 is Glazed subway tile. They cannot be installed on the floor. What is correct tile specification for wall and floor location?
Response: Please refer to specification section 093013-3.6: ceramic tile CT-1 is designated for the walls, while ceramic tile CT-2 is specified for the flooring. See attached updated finish schedule in sheet A5.1.
13. Question: What base is CT-2 per room finish schedule?
Response: Please refer to the updated finish schedule 1/A5.1 attached to this addendum. Base tile CT-1 should be specified for the rooms as listed in the schedule.
14. Question: What to install at the top of the wainscot? Schluter trim or bullnose (if available)?
Response: Please refer to specification section 093013 – 2.4.c, d, e, f, g. Bullnose is at the top of the wainscot.
15. Question: Any water proofing / crack isolation required?
Response: Waterproofing or crack isolation is not required.
16. Question: Is this correct material for LVT?
Response: Yes, the LVT material is specified in section 096519-2.2 of the specifications.
17. Question: Is this correct material description for B-1 wall base?
Response: Yes, the B-1 wall base material is specified in section 096513 -2.1 of the specifications.
18. Question: During the walkthrough, it was noted that there is a recess in the cooler slab that would need to be filled after the cooler is removed. However, upon reviewing the building’s existing plans, we could not find any mention of a recess, only a reference to a trench beneath the cooler. (See attached plan) Could you please clarify?
Response: It has been confirmed that the cooler/freezers do not recess into the slab. The floor insulating panels sit on top of the slab.
19. Question: Additionally, after reviewing the RFD, alternate 6.2.2.1 references” the flooring in the corridors or stairwells”. Could you confirm whether the stairwell flooring is included in the scope as well?
Response: The alternate does not include flooring in the stairwells.
20. Question: Should the bathrooms in the apartments be included in the base bid or part of the alternate?
Response: The bathroom scope for the apartments shall be included in the base bid.
21. Question: The electrical A&E guidelines call for compression fittings on EMT, can we use set screw?
Response: Steel set screw fittings are allowed on EMT in conditioned spaces. Die-cast set screw fittings are not allowed.
Electrical and Plumbing:
See attached description and reissued sheets for revisions to electrical and plumbing documents.
http://www.arkitex.com/
S H
S U
B el vi n
H al l B el vi n B uc ha na n
H al l, 7t h
S t, H un ts vi lle T
X
Revisions Number Date
PRELIMINARY
INTERIM REVIEW ONLY
Document is not complete and may not be used for regulatory approval, permit, or construction.
Architect: Eva Read-Warden Registration No: 15353 Date: 10/24/24
A5.1
R en ov at io n of
Project 24008 24 October, 2024
SCHEDULES
Revision#1 10/25/2024
ROOM NO.
101A 102A 105A 106A 109A 110A 113A 114A 117A
119A
121A
128A
129A
134T
141A
144A
201A 202A 205A 206A 209A 210A 213A 214A 219A
224A
229A 230A 233A 234A 239A 240A
245A
249A 301A 302A 305A 306A 309A 310A 313A 314A 317A
323A
328A 329A 332A 333A 338A 339A
345A
346A
G00C4 G1A G2A G5A G6
G8A G9A
G12A G13A G17A G19A G25 G26 G29
G29C1 G31 G36
G36A
ROOM NAME
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
ADA ROOM
BATH
LAUNDRY
ADA ROOM
BATH
CORRIDOR
CORRIDOR
BATH
ADA ROOM
BATH
LOBBY
RESTROOM
LOUNGE
OFFICE
OFFICE
ROOM
KITCHEN
ADA ROOM
BATH
APT.
ADA ROOM
ROOM
BATH
VESTIBULE
CORRIDOR
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
LAUNDRY
BATH
CORRIDOR
CORRIDOR
BATH
BATH
BATH
BATH
BATH
BATH
KITCHEN/LAUNDRY
BATH
APT.
VESTIBULE
ROOM
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
BATH
LAUNDRY
BATH
CORRIDOR
CORRIDOR
BATH
BATH
BATH
BATH
BATH
BATH
KITCHEN/LAUNDRY
APT.
BATH
ROOM
BATH
VESTIBULE
CORRIDOR
BATH
BATH
BATH
NEW LAUNDRY
BATH
BATH
BATH
BATH
BATH
BATH
CORRIDOR
CORRIDOR
OFFICES
CORRIDOR
NEW CLASSROOM
ROOM
NEW OFFICE
WALL
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
PT-1
CT-1,PT-1
Existing
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
Existing
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
PT-1
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
Existing
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
CT-1,PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
PT-1
FLOOR
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
CT-2
LVT-1
LVT-1
CT-2
LVT-1
LVT-1
CT-2
LVT-1
CT-2
LVT-1
CT-2
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
LVT-1
CT-2
LVT-1
LVT-1
LVT-1
CT-2
LVT-1
LVT-1
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
CT-2
LVT-1
LVT-1
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
CT-2
LVT-1
LVT-1
LVT-1
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
CT-2
LVT-1
LVT-1
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
LVT-1
CT-2
LVT-1
CT-2
LVT-1
LVT-1
CT-2
CT-2
CT-2
LVT-1
CT-2
CT-2
CT-2
CT-2
CT-2
CT-2
LVT-1
LVT-1
Existing
LVT-1
LVT-1
LVT-1
LVT-1
BASE
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1
CT-1
B-1 B-1
CT-1
B-1 B-1
CT-1
B-1
CT-1
Ptd. Exist Base
CT-1
Ptd. Exist Base
B-1 B-1 B-1 B-1 B-1
CT-1
B-1 B-1 B-1
CT-1
B-1 B-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1
CT-1
B-1 B-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1
CT-1
B-1 B-1 B-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1
CT-1
B-1 B-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1 B-1
CT-1
B-1
CT-1
B-1 B-1
CT-1
CT-1
CT-1
B-1
CT-1
CT-1
CT-1
CT-1
CT-1
CT-1
B-1 B-1 B-1 B-1 B-1 B-1 B-1
CEILING
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Existing
Ptd. Gyp.
Ptd. Gyp./Existing ACT
Existing Ptd. Gyp.
Existing Existing
Ptd. Gyp.
Existing
Ptd. Gyp.
ACT-1
ACT-1
Ptd. Gyp.
Existing Existing
ACT-1
ACT-1
Existing Ptd. Gyp.
ACT-1
Existing
ACT-1
Ptd. Gyp.
Existing Existing
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Existing Existing
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
ACT-1
Ptd. Gyp.
ACT-1
Existing
ACT-1
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Existing Existing
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
ACT-1
ACT-1
Ptd. Gyp.
ACT-1
Ptd. Gyp.
Existing
ACT-1
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Ptd. Gyp.
Existing Existing Existing Existing
ACT-1
ACT-1
ACT-1
REMARKS
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF Semi-gloss paint
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF
CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF Semi-gloss paint CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF CT-1 to 6'-4" AFF
WIDTH HEIGHTTYPE NOTESDOOR # FRAME HEAD JAMB
3'-0" 7'-0"
SIGNAGE
Type H - 4/A5.1
HARDWARE SET
7'-0" 2
A
3'-0"
3'-0" 7'-0" 7'-0"
6'-8"3'-0"
3'-0" 6'-8" 1
3'-0" 1
Pocket Door
6'-0" 7'-0" 3'-0" 7'-0" 3'-0" 7'-0"
7'-0"3'-0" 7'-0"3'-0"
3'-0" 7'-0" 2 7'-0" 13'-0"
7'-0"
3'-0"
7'-0"3'-0"
7'-0" EXIST.3'-0"
15'-0" Double door 2'-8"
3'-0"
2'-8"
2'-8"
TYPE B
Wood door
A A A
A B A A B
B
B
EXIST.
A A
B B A
3'-0" 7'-0" 2C
T
TYPE C
Hollow metal door with 1" insulated, low-E clear glass
6'-8" 6'-8"
6'-8"
6'-8" 6'-8"
6'-8" 13'-0"B
6'-8" 12'-0"B
6'-8"3'-0"A
6'-8" 13'-0"B
6'-8" 12'-0" 6'-8" 12'-8"
Double door
3'-0" 7'-0" 2D
TYPE D
Hollow metal door with 1" insulated
Pocket Door
B B
B B
B B
3'-0" 7'-0"A 2
TYPE A
Painted wood 20min fire-rated door
Provide 1" door undercut
Provide 1" door undercut
Provide 1" door undercut Existing door and frame
Provide 1" door undercut
Provide 1" door undercut
Provide 1" door undercut
6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1 6/A5.1 5/A5.1
6/A5.1-sim 5/A5.1-sim 6/A5.1 5/A5.1
6/A5.1 5/A5.1 6/A5.1 5/A5.1
6/A5.1 5/A5.1 6/A5.1 5/A5.1
6/A5.1 5/A5.1
6/A5.1 5/A5.1
8/A5.1 7/A5.1
8/A5.1 7/A5.1
8/A5.1 7/A5.1
8/A5.1 7/A5.1
EXIST. EXIST.
8/A5.1 7/A5.1 8/A5.1 7/A5.1
8/A5.1 7/A5.1 8/A5.1 7/A5.1
8/A5.1 7/A5.1 8/A5.1 7/A5.1 8/A5.1 7/A5.1
8/A5.1 7/A5.1
8/A5.1 7/A5.1
Type C.1- 4/A5.1
7'-0"3'-0" EXIST.EXIST. Existing door and frameEXIST. EXIST.
7'-0"3'-0" EXIST.EXIST. Existing door and frameEXIST. EXIST.
7'-0"3'-0" 1B Provide 1" door undercut8/A5.1 7/A5.1
EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.6'-8"
EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.6'-8"
7'-0" EXIST.3'-0"EXIST. Existing door and frameEXIST. EXIST.
Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type B.3 - 4/A5.1
Type B.3 - 4/A5.1 Type B.3 - 4/A5.1 Type A.1 - 4/A5.1
Type A.1 - 4/A5.1 Type B.3 - 4/A5.1
Type A.1 - 4/A5.1
Type A.1 - 4/A5.1
Type A.1 - 4/A5.1
Type C.1- 4/A5.1
Type A.1 - 4/A5.1
Type A.1 - 4/A5.1
Type B.3 - 4/A5.1
Type B.3 - 4/A5.1
8/A5.1 7/A5.1
8/A5.1 7/A5.1
G6
139A
141A
G31
GC4A
GC4B
119B 119A
121A 121B
123B
129B 131A
139B
G36A
141B 141C 143A 143B 143C
G36B
G26
123A
129A
131B
6"
6"
6"
6"
3' -4
0'-0" finished floor
CL
NOTE
1. "T" denotes tempered glass.
2 Typical Hollow Metal1 Typical wood
Braille type II
5/8" letter size, verify font style w/ Owner
3/4" letter size, verify font style w/ Owner
48" A.F.F.
TYPE H
(Restroom signs)
TYPE C.1
(Office ID signs)
Braille type II
5/8" letter size, verify font style w/ Owner
3/4" letter size, verify font style w/ Owner
48" A.F.F.
TYPE B.1
(Informational signs)
5/8" letter size, verify font style w/ Owner
48" A.F.F.
TYPE B.3
(Room ID signs)
5/8" letter size, verify font style w/ Owner
48" A.F.F.
Braille type II
Changeable message
NOTE:
-Verify all sign location, text, and style with the Owner.
-Mount wall signs 9" apart from center of the sign to door jambs, typical.
- Provide matching opaque backing at opposite side of glass-where signs are mounted on glass doors or sidelites.
-Contractor shall be responsible for submitting a sign schedule from sign manufacturer to the Owner for verification prior to start of manufacturing process.
-Provide manufacturer's full range color/finish for Architect's selection.
-Replace all existing room and way finding signage per SHSU sign standards.
TYPE A.1
(ADA Room ID signs)
5/8" letter size, verify font style w/ Owner
48" A.F.F.
Braille type II Braille type IIMolly Jones
OFFICE
1/
4" 6"
1/4" 6" 1/4"
1/ 4"
6"
6 1/2" 1/4" 6" 1/4"
1/ 4"
1" 1/
4"
1/ 4"
1/ 4"
1/ 4"
6"
6" 1/4" 5 1/2" 1/4"
2" 1/
4" 1/
4" 2"
6"
8"
1/4" 7 1/2" 1/4"
1/ 4"
1/
2"
3"
6"
1/ 4"
1/
2" 1/
4"
1/4" 5 1/2"
1/4"
1/ 4"
EXIT
ONLY
STORAGE
Jamp anchor clips,
(3) per jamb
Scheduled hollow metal frame and door
Double nested studs
Scheduled partition
2" 3/
8" Sc he du le d op en in g
Face of wall where occurs
Scheduled hollow metal frame and door
Box beam
Scheduled partition
2" Sc he du le d op en in g
Scheduled door
Double nested studs
Scheduled partition
Wood door frame to match existing
2" S ch ed ul ed op en in g
Box beam
Scheduled partition
Scheduled door
Wood door frame to match existing
2" S ch ed ul ed op en in g
Scheduled aluminum frame and glass
Sealant and backer rod, both sides Shim
Continuous wood blocking
Scheduled opening
Existing wall assembly
2"
3/8"
Face of stud, typical
Sc he du le d op en in g
2"
3/ 8"
Shim
Continuous wood blocking and shim
Scheduled aluminum frame and glass. Door at sim.
Sealant and backer rod both sides
Existing exterior wall assembly
New boring though existing masonry wall; verify size with Plumbing
Masonry anchors
Flange
Nozzle
Sealant
Thread adapter/piping;
refer to Plumbing
New stainless steel thru-wall sleeve;
seal at face of wall
1 FINISH SCHEDULE2 DOOR SCHEDULE & TYPE
Scale: 1/4" = 1'-0"3 FRAME TYPE
Scale: 3" = 1'-0"4 SHSU SINAGE Refer to 2/A5.1
Scale: 3" = 1'-0"5 HOLLOW METAL DOOR JAMB Refer to 1/A2.1
Scale: 3" = 1'-0"6 HOLLOW METAL DOOR HEAD Refer to 1/A2.1
Scale: 3" = 1'-0"7 WOOD DOOR JAMB Refer to 1/A2.1
Scale: 3" = 1'-0"8 WOOD DOOR HEAD Refer to 1/A2.1
Scale: 3" = 1'-0"9 STOREFRONT JAMB Refer to 1/A2.1
Scale: 3" = 1'-0"10STOREFRONT HEAD Refer to 1/A2.1
Scale: 3" = 1'-0"11DOWNSPOUT NOZZLE DETAIL Refer to 1/A2.2
Note:
- All doors listed are new unless otherwise noted.
Note:
- Not all rooms appear on finish schedule. However, all rooms within Belvin Buchanan Hall are to be painted within the scope of this project..
-All paint at restrooms and bathrooms to be semi-gloss.
T:\230928\Construction Admin\Addenda\Addendum No. 001.docx
300 West 26th Street, Bryan, Texas 77803
P: 979.341.8181 | TBPE No. F-9357
Addendum No. 001
Project: SHSU Belvin Hall
Project No. 230928
Date: 10/25/2024
This Addendum forms a part of the Contract Documents. This addendum modifies and supplements the Contract Documents as described herein for the afore referenced Project and includes:
• Two (2) page narrative
• Zero (0) attachment(s)
• Nineteen (19) revised drawing sheet(s)
Changes to Drawings
Electrical
1. Sheet ED1.0 – Electrical Demolition Plan – Ground Floor
a. Removed references to replacing panels under this contract scope.
2. Sheet ED1.1 – Electrical Demolition Plan – First Floor
a. Removed references to replacing panels under this contract scope.
3. Sheet ED1.2 – Electrical Demolition Plan – Second Floor
a. Removed references to replacing panels under this contract scope.
4. Sheet ED1.3 – Electrical Demolition Plan – Third Floor
a. Removed references to replacing panels under this contract scope.
5. Sheet ED4.1 – Belvin Power Riser Diagram - Demolition
a. This sheet has been deleted from the set. This scope will be completed under a separate contract.
6. Sheet ED4.2 – Buchanan Power Riser Diagram - Demolition
a. This sheet has been deleted from the set. This scope will be completed under a separate contract.
7. Sheet E1.0 – Electrical Lighting Plan – Ground Floor
a. Added General Plan Note.
8. Sheet E1.1 – Electrical Lighting Plan – First Floor
a. Redefined area of ceiling work to match Architect’s RCP.
b. Added General Plan Note.
9. Sheet E1.2 – Electrical Lighting Plan – Second Floor
a. Redefined area of ceiling work to match Architect’s RCP.
b. Added General Plan Note.
10. Sheet E1.3 – Electrical Lighting Plan – Third Floor
a. Added General Plan Note.
11. Sheet E2.0 – Electrical Power Plan – Ground Floor
a. Removed references to replacing panels under this contract scope.
b. Moved panel GLE to a new location.
12. Sheet E2.1 – Electrical Power Plan – First Floor
a. Removed references to replacing panels under this contract scope.
10/25/2024
Addendum No. 001 | Page 2 of 2
T:\230928\Construction Admin\Addenda\Addendum No. 001.docx
13. Sheet E2.2 – Electrical Power Plan – Second Floor
a. Removed references to replacing panels under this contract scope.
14. Sheet E2.3 – Electrical Power Plan – Third Floor
a. Removed references to replacing panels under this contract scope.
15. Sheet E4.1 – Belvin Power Riser Diagram – New Work
a. This sheet has been deleted from the set. This scope will be completed under a separate contract.
16. Sheet E4.2 – Buchanan Power Riser Diagram – New Work
a. This sheet has been deleted from the set. This scope will be completed under a separate contract.
17. Sheet E5.1 – Electrical Ground Floor Panel Schedules
a. Removed Switchboard MSB, Panel GLD and Panel GLF as there is no scope in them.
b. Updated Panel GLE to identify circuits in this project scope.
18. Sheet E5.2 – Electrical Ground Floor Panel Schedules
a. Removed Panel GLJ and Panel GLK as there is no scope in them.
b. Updated Panel GLG and Panel GLH to identify circuits in this project scope.
19. Sheet E5.3 – Electrical First Floor Panel Schedules
a. Removed Panel 1LA and Panel 1LC as there is no scope in them.
b. Updated Panel 1LB and Panel L1A to identify circuits in this project scope.
20. Sheet E5.4 – Electrical Second Floor Panel Schedules
a. Removed Panel 2LA and Panel 2LC as there is no scope in them.
b. Updated Panel 2LB and Panel L2A to identify circuits in this project scope.
21. Sheet E5.5 – Electrical Third Floor Panel Schedules
a. Removed Panel 3LA as there is no scope in this panel.
b. Updated Panel 3LB, Panel L3A and Panel 3LC to identify circuits in this project scope.
Plumbing
1. Sheet P0.0 – Plumbing Symbols and Abbreviations
a. Added note that site investigation to locate the existing storm lines to Civil is to be done by the contractor as part of the scope of this project.
2. Sheet P1.0 – Plumbing Plan – Ground Floor
a. Added note that site investigation to locate the existing storm lines to Civil is to be done by the contractor as part of the scope of this project.
COVERED
CONCRETE WALK
CONCRETE
WALK WAY
UP
DN
DN
UP
DN
DN
MECH
G00U4
CORRIDOR
G29C1
OFFICES
G29
RESTROOM
N.I.C.
G39T1
JAN
N.I.C.
G38J1
LOADING DOCK
N.I.C.
G38J1
DRESSING
N.I.C.
G43A
STORAGE
N.I.C.
G58A
COLLABORATION STUDIO
N.I.C.
G58
STAGE
N.I.C.
G43
THEATRE
N.I.C.
G42
CORRIDOR
N.I.C.
G00C3
MECH
G00U3
STORAGE
G31
G6
CORRIDOR
G26
MECH
G00U2
C O
R R
ID
O
R G
N.I.C.
G23
F
MECH
G00U1
STAIRS
N.I.C.
G27
MECHANICAL
G00U3
ROOM
G14
ROOM
G12
ROOM
G10
ROOM
G8
RESIDENT ADVISOR
G2
RESIDENT ADVISOR
G1
ROOM
G3
ROOM
G5
ROOM
G7
ROOM
G9
ROOM
G11
ROOM
G13
ROOM
G15
ROOM
G17
ROOM
G19
ROOM
G21
STAIRS
G0
JAN
G6J
MECH
G00U3
VEST
N.I.C.
100V1
WOMEN'S RR
G45W1
MEN'S RR
G44M1
VEST
N.I.C.
G00V2
LOUNGE
N.I.C.
G46
CONCESSION STORAGE
N.I.C.
G47
CONCESSION
N.I.C.
G48
VEST
N.I.C.
G00V3
FOYER
N.I.C.
G00L1
LOBBY
N.I.C.
G49
RECEPTION DESK
N.I.C.
G50
GALLERY
N.I.C.
G51
LOUNGE
N.I.C.
G52
REHEARSAL STUDIO
N.I.C.
G57
VAE ACOUSTIC STUDIO
N.I.C.
G53
CORRIDOR
N.I.C.
G00C3
ISOLATION STUDIO
N.I.C.
G54
ISOLATION STUDIO
N.I.C.
G55
ISOLATION STUDIO
N.I.C.
G56
STAIR TO NO WHERE
N.I.C.
G59
ELEV
N.I.C.
G00E1
C O
R R
ID
O
R G
C
MECHANICAL
G00U4
MECHANICAL
G00U5
ELEV. EQUIP. ROOM
N.I.C.
G00U6
MAINT / STORAGE
N.I.C.
G62
MUSIC STUDIO
N.I.C.
G61
DIGITAL STUDIO
N.I.C.
G60
CORRIDOR
N.I.C.
G00C1
FREEZER
G36A1
DRY STORAGE
G36A
COOLER 2
G36B
COOLER 1
G36C
OFFICE
G29A
OFFICE
G29B
OFFICE
G29C
CONTROL BOOTH
N.I.C.
G41
SD
SD
SD
SD
J J J
F
F
F
ELECTRICAL DEMOLITION
PLAN - GROUND FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
ED1.0
ELECTRICAL DEMOLITION PLAN - GROUND FLOOR1
1/8" = 1'0"
KEYED PLAN NOTES:
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
EXISTING COOLERS/FREEZERS TO BE REMOVED. REMOVE ASSOCIATED
WIRING AND CONDUIT BACK TO PANELS.
COOLER CONDENSING UNIT TO BE REMOVED. REMOVE ALL ASSOCIATED
WIRING/CONDUIT BACK TO PANELS.
EXISTING PANEL GLA TO REMAIN.
EXISTING EQUIPMENT DISCONNECT TO BE REMOVED. REMOVE ALL
ASSOCIATED WIRING AND CONDUIT.
EXISTING SMOKE DETECTOR TO BE RELOCATED. REFER TO SHEET E2.0 FOR
NEW LOCATION.
EXISTING FIRE ALARM AV DEVICE TO BE RELOCATED. REFER TO SHEET E2.0
FOR NEW LOCATION.
EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS
SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL
BE REPLACED FOR INSTALLATION OF NEW DEVICES.
EXISTING KITCHEN HOOD/LIGHTING TO REMAIN.
ED1.0
30'20'10'0
SCALE: 1/8"=1'-0"
5'
GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)
1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES
2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE
ON ADJACENT SURFACES AND AREAS.
3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO
REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.
4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.
5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING
TRANSPORT AND STORAGE.
6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.
PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.
7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.
8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.
GENERAL NOTE
ALL EQUIPMENT/DEVICES
SHOWN SHALL BE REMOVED,
UNLESS OTHERWISE NOTED.
ADDENDUM #1 10/25/241
DNUP
DN
DN
DNUP DNUP
RESIDENT ADVISOR
ADA ROOM
ADA ROOM
ADA ROOM
RESTROOM
134T
LAUNDRY
120 STORAGE
139OFFICE
OFFICE
LOUNGE
LOBBY
ROOM
ROOM
JAN
125J
CORRIDOR
C O
R R
ID
O
R
ROOM
ROOM
MECH
MECH
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
RESIDENT ADVISOR
CORRIDOR
HALL STO
VESTIBULE
ROOM
ROOM
STAIRS
STAIRS
STAIRS
MECHANICAL
ELEV
ADA ROOM
ADA ROOM
F
SD
SD
SD SD
SD
SD
J
V
V
J
SD
11 11
12 12
15 16
16 16
16 16
F
F
F
ELECTRICAL DEMOLITION
PLAN - FIRST FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
ED1.1
ELECTRICAL DEMOLITION PLAN - FIRST FLOOR1
1/8" = 1'0"
ED1.1
KEYED PLAN NOTES:
NOT USED.
NOT USED.
NOT USED.
EXISTING FIRE ALARM CONTROL PANEL TO REMAIN.
NOT USED.
EXISTING FIREPLACE TO BE REMOVED. EXISTING FIREPLACE RECEPTACLE
TO REMAIN FOR CONNECTION TO NEW FIREPLACE. REFER TO SHEET E2.1.
EXISTING FIRE ALARM PULL STATION TO REMAIN.
EXISTING FIRE ALARM A/V DEVICE TO REMAIN.
EXISTING DRYER RECEPTACLE TO BE REMOVED. REMOVE ASSOCIATED
WIRING AND CONDUIT BACK TO PANEL.
EXISTING FIRE ALARM A/V DEVICE TO BE REMOVED AND REUSED. REFER
TO SHEET E2.1 FOR NEW LOCATION.
EXISTING VENDING MACHINE RECEPTACLE TO BE REMOVED. REMOVE TO
ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT SHALL REMAIN FOR
CONNECTION TO NEW VENDING MACHINE. REFER TO SHEET E2.1 FOR NEW
LOCATION.
EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO
SHEET E2.1 FOR NEW LOCATION.
EXISTING 3-WAY SWITCH TO BE REMOVED.
EXISTING LIGHT FIXTURE TO BE DEMOLISHED.
EXISTING FIRE ALARM VISUAL DEVICE TO BE REMOVED AND REUSED.
REFER TO SHEET E2.1 FOR NEW LOCATION.
EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS
SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL
BE REPLACED FOR INSTALLATION OF NEW DEVICES.
30'20'10'0
SCALE: 1/8"=1'-0"
5'
GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)
1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES
2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE
ON ADJACENT SURFACES AND AREAS.
3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO
REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.
4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.
5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING
TRANSPORT AND STORAGE.
6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.
PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.
7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.
8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.
GENERAL NOTE
ALL EQUIPMENT/DEVICES
SHOWN SHALL BE REMOVED,
UNLESS OTHERWISE NOTED.
ADDENDUM #1 10/25/241
DNUP DN UP
C ROOM
ROOM
LAUNDRY
225J
C O
R R
ID
O
R
CORRIDOR
VESTIBULE
STO
221A
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
STO
MECH
222U3
STO
ROOM
MECH
218U2
ROOM
217 ROOM
UTIL
215U1
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
RESIDENT ADVISOR
RESIDENT ADVISOR
MECH
236U6
MECH
235U5
STAIRS
N.I.C.
STAIRS
N.I.C.
STAIRS
N.I.C.
ELEV
N.I.C.
F F
SD
SD
SD
V
8 8
7 7
7 7
7 7
7 7
ELECTRICAL DEMOLITION
PLAN - SECOND FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
ED1.2
ELECTRICAL DEMOLITION PLAN - SECOND FLOOR1
1/8" = 1'0"
ED1.2
KEYED PLAN NOTES:
NOT USED.
NOT USED.
NOT USED.
NOT USED.
EXISTING DYER TO BE RELOCATED. REMOVE ASSOCIATED WIRING AND
CONDUIT TO ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT TO
REMAIN. REFER TO E2.2, KEYED NOTE 5.
EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO
SHEET E2.2 FOR NEW LOCATION.
EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS
SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL
BE REPLACED FOR INSTALLATION OF NEW DEVICES.
EXISTING FIRE ALARM DEVICE TO BE REPLACED WITH LOW FREQUENCY
HORN/STROBE DEVICE.
30'20'10'0
SCALE: 1/8"=1'-0"
5'
GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)
1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES
2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE
ON ADJACENT SURFACES AND AREAS.
3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO
REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.
4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.
5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING
TRANSPORT AND STORAGE.
6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.
PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.
7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.
8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.
GENERAL NOTE
ALL EQUIPMENT/DEVICES
SHOWN SHALL BE REMOVED,
UNLESS OTHERWISE NOTED.
ADDENDUM #1 10/25/241
DNDN
DN
ROOM
ROOM
344STORAGE
MECH
300U1
304J1 M
UTIL
315U2
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
STO
STO
ROOM
ROOM
ROOM
ROOM
315 ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
RESIDENT ADVISOR
RESIDENT ADVISOR
MECH
325J2
STAIRS
C O
R R
ID
O
R
STAIRS
STAIRS
STO
322U4
MECH
320U3 MECH
334U6
MECH
335U5
VESTIBULE
CORRIDOR
ELEV
LAUNDRY
a a a a a a a a a a a a a a a a a a
SD
a
SD
a a a a a SD
V
F F 7 7
8 8
66666
6 6
ED1.3
ELECTRICAL DEMOLITION
PLAN - THIRD FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
ELECTRICAL DEMOLITION PLAN - THIRD FLOOR
1/8" = 1'-0"
KEYED PLAN NOTES:
NOT USED.
NOT USED.
NOT USED.
NOT USED.
EXISTING DRYER TO BE RELOCATED. REMOVE ASSOCIATED WIRING AND
CONDUIT TO ABOVE CEILING JUNCTION BOX. EXISTING CIRCUIT TO
REMAIN. REFER TO E2.3, KEYED NOTE 5.
EXISTING RECEPTACLE, SWITCH AND LIGHT(S) TO BE REMOVED. CIRCUITS
SHALL REMAIN FOR CONNECTING NEW DEVICES. SURFACE BOXES SHALL
BE REPLACED FOR INSTALLATION OF NEW DEVICES.
EXISTING FIRE ALARM DEVICE TO BE REPLACED WITH LOW FREQUENCY
HORN/STROBE DEVICE.
EXISTING SMOKE DETECTOR TO BE REMOVED AND REUSED. REFER TO
SHEET E2.3 FOR NEW LOCATION.
30'20'10'0
SCALE: 1/8"=1'-0"
5'
GENERAL DEMOLITION NOTES: (APPLIES TO ALL DEMOLITION SHEETS)
1. SEE OTHER SHEETS FOR ADDITIONAL DEVICES
2. GENERAL: EXCEPT FOR ITEMS OR MATERIALS INDICATED TO BE REUSED, SALVAGED, REINSTALLED, OR OTHERWISE INDICATED TO REMAIN OWNER'S PROPERTY, REMOVE DEMOLISHED MATERIALS FROM PROJECT SITE AND LEGALLY DISPOSE OF THEM IN AN EPA-APPROVED LANDFILL. DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON-SITE REMOVE FROM OWNER OCCUPIED AREAS DAILY. REMOVE AND TRANSPORT DEBRIS IN A MANNER THAT WILL PREVENT SPILLAGE
ON ADJACENT SURFACES AND AREAS.
3. TRACE CIRCUITS FEEDING EXISTING TO-REMAIN PORTIONS OF THE BUILDING. DO NOT DEMOLISH CIRCUITS IN THESE AREAS. IF CIRCUITS ARE IN BOTH "TO
REMAIN" AND "TO BE REMOVED" AREAS, DEMOLISH BACK TO NEAREST TO-REMAIN J-BOX.
4. DEMOLISH AND REMOVE EXISTING CONSTRUCTION ONLY TO THE EXTENT REQUIRED BY NEW CONSTRUCTION AND AS INDICATED. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT LOWER LEVEL.
5. REMOVED AND SALVAGED ITEMS: CLEAN SALVAGED ITEMS, PACK OR CRATE ITEMS AFTER CLEANING. IDENTIFY CONTENTS OF CONTAINERS. STORE ITEMS IN A SECURE AREA UNTIL DELIVERY TO OWNER. TRANSPORT ITEMS TO OWNER'S STORAGE AREA DESIGNATED BY OWNER. PROTECT ITEMS FROM DAMAGE DURING
TRANSPORT AND STORAGE.
6. REMOVED AND REINSTALLED ITEMS: CLEAN AND REPAIR ITEMS TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED REUSE. PAINT EQUIPMENT TO MATCH NEW EQUIPMENT. PACK OR CRATE ITEMS AFTER CLEANING AND REPAIRING. IDENTIFY CONTENTS OF CONTAINERS. PROTECT ITEMS FROM DAMAGE DURING TRANSPORT AND STORAGE. REINSTALL ITEMS IN LOCATIONS INDICATED. COMPLY WITH INSTALLATION REQUIREMENTS FOR NEW MATERIALS AND EQUIPMENT.
PROVIDE CONNECTIONS, SUPPORTS, AND MISCELLANEOUS MATERIALS NECESSARY TO MAKE ITEM FUNCTIONAL FOR USE INDICATED.
7. EXISTING ITEMS TO REMAIN: PROTECT CONSTRUCTION INDICATED TO REMAIN AGAINST DAMAGE AND SOILING DURING SELECTIVE DEMOLITION. WHEN PERMITTED BY ARCHITECT, ITEMS MAY BE REMOVED TO A SUITABLE, PROTECTED STORAGE LOCATION DURING SELECTIVE DEMOLITION AND REINSTALLED IN THEIR
ORIGINAL LOCATIONS AFTER SELECTIVE DEMOLITION OPERATIONS ARE COMPLETE.
8. COORDINATE ALL DEMO ACTIVITIES WITH OWNER AND ARCHITECT AND PROVIDE 10 DAYS NOTICE FOR ANY POWER OUTAGES.
GENERAL NOTE
ALL EQUIPMENT/DEVICES
SHOWN SHALL BE REMOVED,
UNLESS OTHERWISE NOTED.
ADDENDUM #1 10/25/241
AutoCAD SHX Text
ED1.3
CONCRETE
WALK WAY
CORRIDOR
G26
ROOM
G10
ROOM
G8
MECHANICAL
G00U5
MECHANICAL
G00U4
BATH
G2A
BATH
G1A
BATH
G8A
BATH
G12A
BATH
G17A
BATH
G19A
MECH
G00U4
C O
R R
ID
O
R G
CORRIDOR
G29C1
OFFICES
G29
RESTROOM
N.I.C.
G39T1
JAN
N.I.C.
G38J1
LOADING DOCK
N.I.C.
G38J1
DRESSING
N.I.C.
G43A
STORAGE
N.I.C.
G58A
COLLABORATION STUDIO
N.I.C.
G58
STAGE
N.I.C.
G43
THEATRE
N.I.C.
G42
CORRIDOR
N.I.C.
G00C3
MECH
G00U3
NEW OFFICE
G36A
NEW CLASSROOM
G31
MECH
G00U2
N.I.C.
G23
F
MECH
G00U1
STAIRS
N.I.C.
G27
MECHANICAL
G00U3
ROOM
G14
ROOM
G12
NEW LAUNDRY
G6
RESIDENT ADVISOR
G2
RESIDENT ADVISOR
G1
ROOM
G3
ROOM
G5
ROOM
G9
ROOM
G11
ROOM
G13
ROOM
G15
ROOM
G17
ROOM (Hearing Impaired)
G19
ROOM (Hearing Impaired)
G21
STAIRS
N.I.C.
G0
MECH
G00U3
VEST
N.I.C.
100V1
WOMEN'S RR
G45W1
MEN'S RR
G44M1
VEST
N.I.C.
G00V2
LOUNGE
N.I.C.
G46
CONCESSION STORAGE
N.I.C.
G47
CONCESSION
N.I.C.
G48
VEST
N.I.C.
G00V3
FOYER
N.I.C.
G00L1
LOBBY
N.I.C.
G49
RECEPTION DESK
N.I.C.
G50
GALLERY
N.I.C.
G51
LOUNGE
N.I.C.
G52
REHEARSAL STUDIO
N.I.C.
G57
VAE ACOUSTIC STUDIO
N.I.C.
G53
CORRIDOR
N.I.C.
G00C3
ISOLATION STUDIO
N.I.C.
G54
ISOLATION STUDIO
N.I.C.
G55
ISOLATION STUDIO
N.I.C.
G56
STAIR TO NO WHERE
N.I.C.
G59
ELEV
N.I.C.
G00E1
C O
R R
ID
O
R G
C
ELEV. EQUIP. ROOM
N.I.C.
G00U6
MAINT / STORAGE
N.I.C.
G62
MUSIC STUDIO
N.I.C.
G61
DIGITAL STUDIO
N.I.C.
G60
CORRIDOR
N.I.C.
G00C1
ROOM
G36
C O
R R
ID
O
R G
C
OFFICE
G29A
CORRIDOR
G29C1
OFFICES
G29
OFFICE
G29B
OFFICE
G29C
CONTROL BOOTH
N.I.C.
G41
BATH
G5A
BATH
G9A
BATH
G13A
C CE
C
C C C C
C
C
C
C
C C
C
C
C
OS
LV
D
(2
F
F
F
F
F
F
F
F F
C C
OS
OS
LVD
OS
OSOS
OS OS
OS
OS
O S
CE
CE CE
X1
X1
LV
D
LV
X1
1 2
3 4 3 4
3 4
3 4
C
C C C C
CH
H H H H
H
C
C
C C
C C
ELECTRICAL LIGHTING
PLAN - GROUND FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
E1.0
ELECTRICAL LIGHTING PLAN - GROUND FLOOR1
1/8" = 1'0"
E1.0
KEYED PLAN NOTES:
NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING
JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW
SENSOR TO EXISTING SWITCHING CONDUCTORS.
INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX
ABOVE MIRROR AND THEN RECONNECT TO EXISTING
CONDUCTORS.
RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING
CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING
CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND
SWITCH AS SHOWN.
PROVIDE NEW CEILING MOUNTED OCCUPANCY SENSORS
AND DIMMING POWER PACKS TO SWITCH AS SHOWN.
LOCATION AND QUANTITY OF POWER PACKS NOT SHOWN.
EXISTING HOOD/LIGHTS TO REMAIN.
30'20'10'0
SCALE: 1/8"=1'-0"
5'
GENERAL NOTES LIGHTING SHEETS:
1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.
COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT
SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.
2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER
SHALL BE CONNECTED AS PER MANUFACTURER.
3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT
LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.
4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.
5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.
6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.
PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.
GENERAL PLAN NOTES:
1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW
VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.
2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY
RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A
NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR
MATCHING EXISTING FIELD CONDITIONS.
3. CONNECT NEW EXIT LIGHTS TO NEAREST UNSWITCHED
LIGHTING CIRCUIT.
4. IN AREAS WHERE EXISTING CEILINGS HAVE BEEN
REMOVED, REMOVE EXISTING LIGHT FIXTURES AND
REPLACE WITH NEW LIGHT FIXTURES. RECONNECT NEW
FIXTURES TO EXISTING LIGHTING CIRCUITS AND SWITCHING
SERVING SPACE.
ADDENDUM #11 10/25/24
W/D
W
W
W
DD
IM
F
CORRIDOR
C O
R R
ID
O
R
CORRIDOR
BATH
144A
BATH
141A
BATH
129A
BATH
121A�
BATH
119A
BATH
117A
BATH
114A
BATH
113A
BATH
106A
BATH
110A
BATH
109A
BATH
105A
BATH
102A
BATH
101A
JAN
125J
RESTROOM
134T
ROOM
ADA ROOM
ROOM
MECH
ADA ROOM
LAUNDRY
ADA ROOM
(Mobility and Hearing Impaired)
MECH
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
RESIDENT ADVISOR
RESIDENT ADVISOR
ROOM
OFFICE
OFFICE
LOUNGE
LOBBY
VESTIBULE
ROOM
ROOM
APT.
ROOM
STAIRS
N.I.C.
STAIRS
N.I.C.
STAIRS
N.I.C.
MECHANICAL
ELEV
ADA ROOM
ADA ROOM
BATH
128A
A
A A
AE
A
A
A
A A A
A
A A
A
A
A A
A A
F F
F F
F F
F
F
F
F
F
F F F
OS
OS
OS
D
D D
OS
OS
OS
OS
OS OS
B B B B
BB
B B
LV
D
OS
LVD
OS
O S
LVD
LV
D
AE
AE AE AE
BE
A
X2
X1
A A
LV
D
LV
LV
D
LV
D
LV
D
1 2
OSOS
OS
OS
OS
3 4
OS
OS
F
G G G
B B B
F
F
F
9 8
J
A1
B1
B1
A1A1
A1 B
B
A
A
A
A
B
ELECTRICAL LIGHTING
PLAN - FIRST FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
E1.1
ELECTRICAL LIGHTING PLAN - FIRST FLOOR1
1/8" = 1'0"
E1.130'20'10'0
SCALE: 1/8"=1'-0"
5'
KEYED PLAN NOTES:
NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING
JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW
SENSOR TO EXISTING SWITCHING CONDUCTORS.
INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX
ABOVE MIRROR AND THEN RECONNECT TO EXISTING
CONDUCTORS.
RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING
CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING
CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND
SWITCH AS SHOWN.
PROVIDE NEW CEILING MOUNTED OCCUPANCY SENSORS
AND DIMMING POWER PACKS TO SWITCH AS SHOWN.
LOCATION AND QUANTITY OF POWER PACKS NOT SHOWN.
ALL NEW LIGHT FIXTURES IN THIS ROOM TO BE SWITCHED
TOGETHER.
NEW SWITCH. CONNECT TO EXISTING FIXTURES IN ROOM.
GENERAL NOTES LIGHTING SHEETS:
1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.
COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT
SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.
2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER
SHALL BE CONNECTED AS PER MANUFACTURER.
3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT
LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.
4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.
5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.
6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.
PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.
GENERAL PLAN NOTES:
1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW
VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.
2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY
RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A
NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR
MATCHING EXISTING FIELD CONDITIONS.
3. CONNECT NEW EXIT LIGHTS TO NEAREST UNSWITCHED
LIGHTING CIRCUIT.
4. IN AREAS WHERE EXISTING CEILINGS HAVE BEEN
REMOVED, REMOVE EXISTING LIGHT FIXTURES AND
REPLACE WITH NEW LIGHT FIXTURES. RECONNECT NEW
FIXTURES TO EXISTING LIGHTING CIRCUITS AND SWITCHING
SERVING SPACE.
DISCONNECT AND REPLACE EXISTING LIGHT FIXTURE WITH
NEW TYPE J STRIP LIGHT WITH LENS. COORDINATE FIXTURE
LOCATION WITH EXISTING MECHANICAL EQUIPMENT, PIPING,
AND DUCTWORK.
SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.
CONNECT TO EXISTING CIRCUIT AND SWITCH AT DOOR AS
SHOWN.
SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.
CONNECT TO LIGHTING CIRCUIT IN ROOM AND SWITCH AT
DOOR AS SHOWN.
ADDENDUM #1 10/25/241
W
D D
W
W
W
TV
C O
R R
ID
O
R
CORRIDOR
VESTIBULE
BATH
249A
BATH
230A
BATH
234A
BATH
240A
BATH
245A
BATH
239A
BATH
233A
BATH
229A
BATH
224A
BATH
219A
BATH
205A
BATH
209A
BATH
213A BATH
214A
BATH
210A
BATH
206A
BATH
202A
BATH
201A
225J
KITCHEN
STO
221A
ROOM
ROOM
APT.
ROOM
ROOM
ROOM (Hearing Impaired)
ROOM
ROOM (Hearing Impaired)
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
STO
MECH
222U3
STO
LAUNDRY
ROOM
MECH
218U2
ROOM
217 ROOM
UTIL
215U1
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
ROOM
RESIDENT ADVISOR
RESIDENT ADVISOR
MECH
236U6
MECH
235U5
STAIRS
N.I.C.
STAIRS
N.I.C.
STAIRS
N.I.C.
ELEV
N.I.C.
W/D
F
2 2
1 1
1 1 1 1 1
B
F F
F F
F F
F F F F
F
F F F F F
OS OS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS OS
OS OS
OS OS
B
B
B
B
B
O S
LV
D
LVD
LVD
OS
1 1
2 2
1 1
2 2
F
1 1 1 1
2 2 2
2 2 2 22
F
B B F
F
B
OS
4 4
B1
B1
B
B B
A
B B
B B
B
ELECTRICAL LIGHTING
PLAN - SECOND FLOOR
SH
SU
B el vi n
H al l Be lv in
B uc ha na n H al l, 7t h St
, H un ts vi lle T
X
Revisions Number Date
R en ov at io n of
Project 230928cz
OCTOBER 2, 2024
RANDY N. ROGERS
NOT FOR REGULATORY APPROVAL,
PERMIT OR CONSTRUCTION
P.E. REG. NO. 82143
REVIEW
10-25-24
PRELIMINARY
E1.2
ELECTRICAL LIGHTING PLAN - SECOND FLOOR1
1/8" = 1'0"
E1.230'20'10'0
SCALE: 1/8"=1'-0"
5'
KEYED PLAN NOTES:
NEW OCCUPANCY SENSOR TO BE INSTALLED IN EXISTING
JUNCTION BOX ADJACENT TO RECEPTACLE. CONNECT NEW
SENSOR TO EXISTING SWITCHING CONDUCTORS.
INSTALL NEW LIGHT FIXTURE TO EXISTING JUNCTION BOX
ABOVE MIRROR AND THEN RECONNECT TO EXISTING
CONDUCTORS.
RECONNECT NEW LIGHT FIXTURES TO EXISTING LIGHTING
CIRCUIT SERVING SPACE. PROVIDE NEW MATCHING
CONDUIT, CONDUCTORS, AND JUNCTION BOXES AND
SWITCH AS SHOWN.
SUPPLY AND INSTALL MINKA AIRE F524-WHF CEILING FAN.
CONNECT TO EXISTING CIRCUIT AND SWITCH AT DOOR AS
SHOWN.
GENERAL NOTES LIGHTING SHEETS:
1. DEVICE LOCATION GUIDELINES: LOCATE DEVICES ADJACENT TO THE DOOR FRAMES 4 INCHES TO THE EDGE OF THE DEVICES AT ADA HEIGHT GUIDELINES. CO-LOCATE SIMILAR DEVICES UNDER A COMMON FACEPLACE (EXAMPLE - MULTIPLE LIGHT SWITCHES). LOCATE ADDITIONAL DEVICES HORIZONTALLY ADJACENT TO EACH OTHER.
COORDINATE SWITCH LOCATIONS IN ROOMS WITH ARCHITECT AND OTHER DEVICES (THERMOSTATS AND FIRE ALARM DEVICES). DO NOT STAGGER DEVICES. ONLY WHEN HORIZONTAL SPACE DOES NOT PERMIT, STACK DEVICES VERTICALLY WITH TWO INCHES BETWEEN FACEPLATES TO NO MORE THAN 72 INCHES AFF TO THE TOP OF THE FACEPLATE. COORDINATE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. DEVICES SHALL BE MOUNTED AT
SPECIFIC DEVICE MOUNTING HEIGHTS AS LISTED PER SPECIFICATIONS.
2. MINIMUM CIRCUIT SIZE IS 2 #12 AND 1 #12 GROUND IN ½” CONDUIT. MAXIMUM FIXTURE WHIP LENGTH FROM ANY J-BOX 6 FEET. LIGHTING CIRCUITS JOINTS SHALL BE MADE UP IN OVERHEAD J-BOXES SECURED TO STRUCTURE WITH LIGHTING WHIPS FROM THE J-BOXES. FIXTURES DESIGNED TO BE QUICK-CLIPPED TOGETHER
SHALL BE CONNECTED AS PER MANUFACTURER.
3. COORDINATE LIGHT LOCATIONS WITH OTHER CEILING ITEMS OR JOIST ITEMS PRIOR TO INSTALLATION. LIGHT
LOCATIONS TAKE PRECEDENCE OVER AIR DEVICES.
4. PROVIDE SECONDARY SUPPORT WIRES FROM ALL FOUR (4) CORNERS OF THE LAY-IN FIXTURES TO THE STRUCTURE ABOVE. DO NOT SUPPORT FIXTURES FROM CEILING GRID WIRE SUPPORTS, PIPING, CONDUIT, SIDE WALLS, OR MECHANICAL EQUIPMENT. CEILING SPECIFICATIONS DO NOT SUPERCEDE THIS REQUIREMENT.
5. FIXTURES WITH “E” SUFFIX HAVE BATTERY BACK-UPS.
6. FIRESTOP ALL CONDUIT PENETRATIONS IN RATED WALLS. SEE ARCHITECTURAL FOR WALL RATINGS.
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO SHEET ROCK AND REPAIR.
PROVIDE FIRE RATED SLEEVES IN ALL FLOOR PENETRATIONS.
GENERAL PLAN NOTES:
1. NEW OCCUPANCY SENSORS NOT SHOWN AS LOW
VOLTAGE (LV) TO BE RATED FOR LINE VOLTAGE.
2. NEW OCCUPANCY SENSORS TO BE DUAL-TECHNOLOGY
RATED. FIELD VERIFY IF EACH SENSOR LOCATION AS A
NEUTRAL CONDUCTOR PRESENT. PROVIDE A SENSOR
MATCHING EXISTING FIELD CONDITIONS.
3. IN AREAS…
This is the start of the file's text. The full file is on GovTribe.