EQUIPMENT LIST.pdf

PDF 72 KB Posted

Attached to
Equipment IST Federal contract opportunity
Solicitation number
SPE3SE23Q0590
Issued by
Defense Logistics Agency Troop Support Subsistence

About this file

This document outlines equipment specifications and installation requirements for a federal contract opportunity with the Defense Logistics Agency Troop Support Subsistence. The opportunity involves providing commercial kitchen equipment for Mess Halls 41 and 33 at Camp Pendleton, including a tray accumulator system, waste collector, combi oven, convection ovens, kettles, fryers, and milk dispenser. The specifications include models, capacities, features, and warranties for each item. Installation scopes of work are also outlined for securing utilities, assembling and installing the new equipment, and performing start-up checks. Product manufacturers include Tragenflex, Salvajor, AltoShaam, Vulcan, Cleveland Range, and Silver King. The opportunity number is listed as SPE3SE23Q0590.

View the file

Other files for this federal contract opportunity

Other files attached to Equipment IST, newest first.
File Type Posted
J and A for 23Q0590.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EQUIPMENT LIST & SPECIFICATIONS/SPE3SE23Q0590/CAMP PENDLETON

ITEM #1

1 ea. ACCUMULATOR

Tragenflex Model No. P222215R‐R1

Rotary tray accumulator system to include:

A. Window frame & sill

B. Sight & sound baffle w/ LED tube lights

C. Rotary tray accumulator:

01‐ 22 22carriers4tier type,88tray capacity

02‐ Stainless steel carriers

03‐ Electrical control panel

04‐ 02)Anti‐jam switches

D. Soiled dish table:

01‐ Waste Trough

02‐ Magnet

03‐ (02)Perforated s/s ledges

04‐ (02) Pre rinse stations

05‐ (02) Gusher head

06‐ (02) Hip switches

07‐ Trough diffuser

08‐ Remote start/sop station

E. Double slat belt accumulator conveyor:

01‐ Anti‐jam switch

02‐ Accumulation Photo Sensor

03‐ (02) Remote start/stop station

F. Hose clean up station

FOR MESS HALL 41

ITEM #2

1 ea INSTALLATION/ASSEMBLY

Tragenflex Model No. ASSEMBLY

ASSEMBLY BY TRAGENFLEX:

A. TragenFlex Factory Technician will arrive at jobsite to field weld, polish and interconnect TragenFlex equipment. This covers all inter electrical and plumbing connections of TragenFlex components only.

B. Assembly to be performed during regular working hours. Overtime, weekend, evening or standby labor time is not included.

C. Assembly is quoted based on Non‐Union/Non‐Prevailing labor rates.

D. Please be advised that all TragenFlex equipment MUST be assembled by TragenFlex Technician(s). Warranty is void if assembled by an unauthorized service agent.

E. PLEASE NOTE THIS ASSEMBLY DOES NOT INCLUDE:

F. Receive, uncrate, unload and delivery of equipment to dish room

G. Electrical and plumbing connection from and to building.

H. Utility service connections of accessory equipment to TragenFlex equipment such as waste equipment or dish machine.

I. Unless specified in our quotation, removal and/or disposal of existing equipment are not included.

FOR MESS HALL 41

ASSEMBLY SERVICE BY TRAGENFLEX IS NOT OPTIONAL. IT IS REQUIRED

IN ORDER FOR TRAGENFLEX TO HONOR THE STANDARD

MANUFACTURER'S WARRANTY.

ASSEMBLY MUST BE PERFORMED BY MANUFACTURER'S CERTIFIED

SERVICE AGENT OR WARRANTY IS VOID.

ITEM #3

1 ea WASTE COLLECTOR

Salvajor Model No. S419

Trough Collector™, trough conveyor & collecting system (widely accepted in areas where disposers are restricted), HYDROLOGIC® with

LCD readout, trough diffuser, salvage basin & silverware trap, scrap basket, 3/4 HP corrosion‐resistant pump, pump intake screen

,stainless steel construction, start/stop pushbutton control panel, with safety line disconnect & automatic shut off timer, UL, CSA, CE, NSF

1 ea Collector top is available to ship to the fabricator in advance of unit

(additional shipping charges will apply). Please provide instructions on order

1 ea 2nd‐year warranty (P/N 999184) (NET)

1 ea Specify voltage

1 ea 419CISS Trough Collector™ full stainless steel cover

4 ea 988001 Gusher head assembly for TVL, TVR & S419

1 ea 992011 Additional scrap basin

1 ea 992013 Additional scrap basket

1 ea 980211 Seismic Flange for Support Leg (3 included)

FOR MESS HALL 41

TO BE BUILT INTO ITEM #1

ITEM #4

1 ea INSTALLATION

ALL TRADES Model No. INSTALL

SCOPE OF WORK FOR ITEMS #1 & #3, TO CONSIST OF THE FOLLOWING:

*Secure and disconnect all utilities to current tray accumulator system.

*Disassemble and remove from space to back dock.

*Assist with removal from dock back to food service warehouse.

*Receive new tray accumulator at the warehouse, unload from the truck and inspect for damage.

*Transport new system to building site and off load into the space.

*Assembly to done by factory team.

*Provide and install water, and drains to new conveyor system.

*Provide and install necessary electrical circuits to new conveyor.

*Install Salvajor Collector on new tray system.

*Provide and install water line for trough.

*Provide and install drain line for collector.

*Provide and install electrical circuit for collector.

*Startup and operational check.

After hours required for removal and installation

QUOTED AFTER HOURS, AS REQUIRED BY CAMP PENDLETON.

ITEM #5

1 ea COMBI OVEN, GAS

Alto‐Shaam Model No. 10‐20G PRO

Prodigi™ Pro Combi Oven/Steamer, gas, boiler‐free, countertop, (10)

18" x 26" full size sheet or (22) 12" x 20" full size hotel pan (GN 1/1) capacity, Wi‐Fi enabled control with steam/convection/combi cooking modes, programmable cool‐down, SafeVent™ steam venting, removable "T" style temperature probe, (3) power levels, (5) cleaning levels, triple‐pan door, high efficiency LED lighting, (2) side racks with

(11) non‐tilt support rails, door hinged right, stainless steel construction, adjustable stainless steel legs, 133,000 BTU, EcoSmart®, cULus, UL EPH Classified, CE, EAC, IPX5

1 ea NOTE: Subject to Manufacturer’s Terms & Conditions. See Documents

Section

1 ea One year parts and labor warranty, standard

1 ea It is the sole responsibility of the owner/operator/purchaser of this equipment to verify that the incoming water supply is comprehensively tested and, if required, provide a means of water treatment that would meet the compliance requirements with the manufacturers water quality standards published on the product spec sheet. Non‐compliance with these minimum standards will potentially damage this equipment and/or components and VOID the original equipment manufacturers warranty

1 ea XP‐SVC START‐UP Installation start‐up check (NOTE: Includes travel within 60 miles (120 miles round‐trip) of installer. Additional trip charges may apply outside the 60‐mile limit. Contact your local factory‐authorized service agent for details)

1 ea Specify gas type

1 ea Natural gas

1 ea TURBO without Smoker, standard

1 ea 120v/60/1‐ph, 6.8 amps, .84kW, 12 AWG, NO cord or plug

1 kt 5026980 Installation Kit, for gas combi ovens, Copper, rated up to 20.0 amps, per oven ((NET) NO FURTHER DISCOUNTS APPLY) (Note:

Required to meet NYC requirements)

1 ea Wifi, standard

1 ea Removable "T" style temperature probe, standard

1 kt CR‐33543 Quick Disconnect Kit, for all gas ovens (one required for each oven, (1) already included if install kit is selected)

1 ea 5016083 Combi Oven Stand, stationary, 25‐7/16" x 39‐13/16" x 36‐5/16"

(645mm x 1010mm x 922mm), with shelf, stainless steel, for 7‐20 or 10‐

20 FOR MESS HALL 33

ITEM #6

4 ea CONVECTION OVEN, GAS

Vulcan Model No. VC44GD

Convection Oven, gas, double‐deck, standard depth, solid state controls, electronic spark igniters, 60 minute timer, (5) nickel plated racks per oven, 8" high legs, stainless steel front, top & sides, stainless steel doors with windows, (2) 50,000 BTU, NSF, CSA Star, CSA Flame, ENERGY STAR®

4 ea 1 year limited parts & labor warranty, standard

4 ea Natural gas (specify elevation if over 2,000 ft.)

4 ea (2) 120v/60/1‐ph, 15.4 amps total, (2) cords with plugs, standard

4 ea Gas manifold piping included with stacking kit to provide single point gas connection

8 ea Simultaneous doors, both ovens

8 ea ENCLSUR‐SSBACK Stainless steel rear enclosure (per section)

8 ea DRIPPAN‐SSDD Drip Pan (per section), stainless steel

4 ea 3/4QD HOSE‐4 3/4" x 4' long gas flex hose & quick disconnect with restraining device

4 st Casters, set of (4) in lieu of standard legs

FOR MESS HALL 33

ITEM #7

2 ea KETTLE, GAS, STATIONARY

Cleveland Range Model No. KGL60SH

Short Series™ Steam Jacketed Kettle, gas, 60‐gallon capacity, full steam jacket design, 37.5" rim height, 316 series stainless steel interior, solid‐state temperature controls, power on/off switch, drain strainer, faucet mounting bracket, spring assisted cover, 2" tangent draw‐off, quad‐leg with flanged feet, 50 psi rating 190,000 BTU

2 ea 1‐year parts & labor warranty, standard

2 ea Performance start‐up included at customer request after equipment is installed (Free Water Quality Check included) (contact Cleveland Sales

Representative for details)

2 ea Natural Gas

2 ea 120v/60/1‐ph, 10.0 amps, electronic spark ignition, cord & plug for controls, standard

2 ea TD3S 3" tangent draw‐off valve with strainer (add on price)

2 ea KM2G Kettle Markings, 5 gallon increments

2 ea DKFK Double Pantry Kettle Filler, with 60" hose

2 ea HS001 Front mounted removable heat deflector shield

2 ea KAK Kettle Accessory Kit, includes: clean up brush, paddle, stainless steel whip, brush, draw‐off brush, ladle

2 ea CP‐RB Heavy duty reinforced rim bar 1/2" x 1" stainless steel bar continuously welded to top & bottom

1 kt Moveable Gas Connector Kit, 1" inside dia., 48" long, covered with stainless steel braid, coated with blue antimicrobial PVC, (1) Snap

Fast™ QD, (1) Swivel MAX®, (1) full port valve, (1) elbow, coiled restraining cable with hardware, 310,000 BTU/hr minimum flow capacity, limited lifetime warranty

FOR MESS HALL 33

ITEM #8

1 ea GAS FRYER, BATTERY

Vulcan Model No. 2VK45DF

PowerFry5™ Fryer, gas, high efficiency, 31" W, (2) battery, 45‐50 lb.

capacity per vat, solid state digital control with melt cycles, FivePass™ heat transfer system, electronic ignition, KleenScreen PLUS® filtration system, twin baskets, stainless steel cabinet & fry tank, adjustable casters (2 swivel locking & 2 non‐locking), 140,000 BTU, CSA, NSF, ENERGY STAR®

1 ea 1 year limited parts & labor warranty, standard

1 ea 10 year limited tank warranty, standard.

1 ea Natural gas (specify elevation if over 10,000 ft. contact factory)

1 ea 120v/60/1‐ph, with cord & plug, standard

1 ea 11/4QDH 4FT 1‐1/4" dia. x 4' flex hose & quick disconnect with restraining device

FOR MESS HALL 2403

ITEM #9

4 ea MILK DISPENSER

Silver King Model No. SKMAJ3‐ESUS4

Majestic Series Milk Dispenser, refrigerated, triple spring‐loaded valve, 18 gallon capacity, (accommodates 3, 5, or 6 gallon bags), includes (3) crates, stainless steel interior & exterior with galvanized bottom, bottom‐mounted self‐contained refrigeration, R290

Hydrocarbon refrigerant, 1/6 HP, 115v/60/1‐ph, 1.9 amps, cord & NEMA

5‐15P, cETLus, ETL‐Sanitation

ITEM #10

1 ea INSTALLATION

ALL TRADES Model No. INSTALL

SCOPE OF WORK TO CONSIST OF THE FOLLOWING, FOR ITEMS 5, 6, 8 &

9:

*Secure and disconnect current utilities.

*Remove equipment to back dock and then transport back to the warehouse.

*Receive new equipment at the food service warehouse and inspect for damage.

*Transport new equipment to mess hall.

*Uncrate set in place and secure equipment as needed.

*Stack ovens.

*Provide all necessary utilities needed for correct operation.

* Provide and install Two New Ansul Heads at MH2403 for new Fryer

Bank *Start‐up and test for proper operation.

QUOTED AFTER HOURS, AS REQUIRED BY CAMP PENDLETON

File details come from the government source that posted it. Updated .