This is a Pre-Demolition Asbestos-Containing Material Survey report prepared by True North Consultants, Inc. for the Village of Schaumburg, Illinois, dated May 11, 2026. The survey was conducted on a residential structure located at 218 West Schaumburg Road in Schaumburg, Illinois in preparation for planned demolition activities. An Illinois Department of Public Health (IDPH) licensed Asbestos Building Inspector (Todd Huffer, License No. 100-09870) performed the visual and physical investigation on May 1, 2026. The survey identified the presence, approximate locations, and estimated quantities of suspect asbestos-containing materials (ACM) throughout the structure. Bulk samples were collected from representative locations according to USEPA AHERA sampling protocols and submitted to a NIST NVLAP accredited laboratory (Sterling Laboratories) for analysis using Polarized Light Microscopy (PLM) with dispersion staining in accordance with USEPA Method 600/R-93/116.
The survey results identified asbestos-containing materials at the site, including 12"x12" peel and stick flooring with 1-5% Chrysotile in the kitchen and entry areas (250 SF), drywall and joint compound with 1-5% Chrysotile in interior sections exceeding 5,000 SF, and various ceiling tiles, window glazing, and roofing materials that tested negative for asbestos. Materials with no asbestos detected include samples from the laundry room, front bathroom, garage entrance closet, back entry vestibule, back living room, backside house windows, and roof field. The scope of sampling was limited to visible and accessible materials only, and any additional suspect ACM identified during demolition activities may require additional testing. The report notes that any materials containing greater than 1% asbestos are regulated by USEPA, OSHA, IDPH, and local agencies.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1000 East Warrenville Road, Ste. 140 Naperville, IL 60563
O: 630.717.2880 F: 630.689.5881
ConsultTrueNorth.com
Trusted Partner. Leading Environmental Solutions.
May 11, 2026
Mark Rysavy Facilities Division Manager Village of Schaumburg 1000 E. Woodfield Rd.
Schaumburg, IL 60173
Subject: Pre-Demolition Asbestos-Containing Material Survey
Residential Structure 218 West Schaumburg Road, Schaumburg, IL 60173
True North Project No. T265663
Dear Mr. Rysavy:
True North Consultants, Inc. (True North) was retained by the Village of Schaumburg (Client) to conduct a pre-demolition asbestos-containing material survey of the residential structure located at 218 West Schaumburg Road in Schaumburg, Illinois (Site). Survey services were provided by an Illinois Department of Public Health (IDPH) licensed Asbestos Building Inspector (Todd Huffer, License No. 100- 09870) on May 1, 2026.
The purpose of the survey was to determine the asbestos content of discovered suspect asbestos-containing materials (ACM) associated with the structure prior to planned demolition activities.
True North conducted a visual and physical investigation of the property to identify the presence, approximate locations, and estimated quantities of suspect asbestos-containing materials present at the Site. Bulk samples of each suspect asbestos-containing material were collected at representative locations in accordance with the sampling protocol identified in the United States Environmental Protection Agency (USEPA) Asbestos Hazard Emergency Response Act (AHERA).
The bulk samples were submitted to a National Institute of Standards and Technology (NIST), National Voluntary Laboratory Accreditation Program (NVLAP) accredited laboratory for analysis (Sterling Laboratories
– Accreditation No. 101768-0). The bulk samples were analyzed for asbestos content in accordance with the procedures for Polarized Light Microscopy (PLM) with dispersion staining, contained in the United States Environmental Protection Agency (USEPA) Method for the Determination of Asbestos in Bulk Building Materials (USEPA/600/R-93/116). Results of sample analysis were reported as a percent (%) composition.
The following is a summary of PLM analytical results for sampled materials:
Summary of Findings: Suspect Asbestos-Containing Materials
Material Description Sample
Number(s) Location(s)
Estimated Quantity
Asbestos Content
12”x12” Peel and Stick Flooring and Mastic
TH050426-01 –
Kitchen and under entry carpet
250 SF
Floor Tile - 1-5% Chrysotile
Mastic – None Detected
PROJECT NO. T265663 / May 11, 2026 Pre-Demolition Asbestos-Containing Material Survey 2
Summary of Findings: Suspect Asbestos-Containing Materials
Material Description Sample
Number(s) Location(s)
Estimated Quantity
Asbestos Content
Drywall and Joint Compound
TH050426-04 –
Interior section of house
>5,000 SF 1-5% Chrysotile
12”x12” Peel and Stick Floor Tile and Mastic
TH050426-07 –
Laundry Room Area
300 SF None Detected
12”x12” Peel and Stick Floor Tile and Mastic
TH050426-10 –
Front Bathroom 150 SF None Detected
1’x1’ Smooth Ceiling Tile and Glue Pucks
TH050426-13 –
Garage Entrance and Closet
300 SF None Detected
12”x12” Peel and Stick Floor and Mastic
TH050426-16 –
Back Entry Vestibule
60 SF None Detected
1’x1’ Fissured Ceiling Tiles and Glue Pucks
TH050426-19 -
Back Living Room 600 SF None Detected
Window Glazing
TH050426-22 –
Backside of House 100 LF None Detected
Roof Field
TH050426-25 –
Roof 6,000 SF None Detected
Notes:
(1) The scope of sampling was limited to the aforementioned materials only. In the event that additional suspect asbestos-containing materials are identified during planned demolition activities, additional testing may be required.
(2) Any quantities of material identified within this report are solely intended to be estimates and are not intended to be exact.
(3) Positive ACM flooring is concealed below plywood board
The USEPA defines “asbestos-containing materials” as those materials that contain greater than 1% asbestos.
Based upon the results of analysis, asbestos-containing materials were identified at the Site.
Due to the health effects associated with asbestos exposure, various federal, state, and local agencies have promulgated standards and regulations for the performance of asbestos-related activities. Specifically, asbestos-containing materials at the Site may be regulated by USEPA, OSHA, IDPH, and other local agencies.
Based upon the findings of the survey, the aforementioned asbestos regulations do apply to the removal or disturbance of these materials.
PROJECT NO. T265663 / May 11, 2026 Pre-Demolition Asbestos-Containing Material Survey 3
The scope of the survey was limited to an evaluation of visible and accessible building materials and did not include an evaluation of building materials that were inaccessible or concealed at the time of the survey. In the event that additional suspect ACMs are identified at the Site, said materials should be presumed to contain asbestos until which time additional testing may be performed to refute this presumption.
Enclosed with this letter are copies of laboratory analytical results and inspector credentials. Should there be any questions regarding this report, please contact us at your convenience.
Sincerely, TRUE NORTH CONSULTANTS, INC.
Todd Huffer Principal Consultant
Attachments: Attachment A – Laboratory Analytical Results Attachment B – Asbestos Building Inspector Credentials Attachment C – Photographic Documentation Attachment D – Floor Plan and Sample Locations
PRE-DEMOLITION ASBESTOS-CONTAINING MATERIAL SURVEY
APPENDIX A
Laboratory Analytical Results
APPENDIX B
Asbestos Inspector Credentials
Enclosed is your Asbestos Professional License. Please note the expiration date on the card and in the image depicted below.
If you have any questions or need further assistance, contact the Asbestos Program at (217)782-3517 or fax
(217)785-5897.
Our WEB address is: dph.illinois.gov/topics-services/environmental-health-protection/asbestos
EMAIL Address: dph.asbestos@illinois.gov
5/3/2025
315 HATLEN COURT
TODD T HUFFER
ASBESTOS PROFESSIONAL LICENSE ID NUMBER: 09870
MT. PROSPECT, IL 60056
Front of License Back of License
COPY OF THE ASBESTOS PROFESSIONAL LICENSE
ASBESTOS
PROFESSIONAL
LICENSE
ID NUMBER
09870
315 HATLEN COURT
Environmental Health
Alteration of this license shall result in legal action This license issued under authority of the State of Illinois
Department of Public Health This license is valid only when accompanied by a valid training course certificate.
ENDORSEMENTS TC EXPIRES
INSPECTOR
MANAGEMENT PLANNER
AIR SAMPLING PROFESSIONAL
PROJECT MANAGER
10/16/2025
1/2/2026
10/16/2025
5/3/2025
ISSUED EXPIRES
05/15/2026100 -
TODD T HUFFER
MT. PROSPECT, IL 60056
APPENDIX C
Photographic Documentation
Pre-demolition Asbestos Survey 218 West Schaumburg, Schaumburg, Illinois
ASSESSMENT DATE: MAY 11, 2026 PROJECT NUMBER: T265663
Photo 1 –
Photo 2 –
Photo 3 –
Photo 4 –
Photo 5 Photo 6
APPENDIX D
FLOOR PLAN AND SAMPLE LOCATIONS
09 07
16 17 18
22 23 24
GARAGE
BACK
LIVING
ROOM
LAUNDRY
BEDROOM
KITCHEN
BEDROOM
BEDROOM
BEDROOM
BATHROOM BATHROOM
25 26 27
ROOF
LEGEND NOTES:
CLIENT
SITE NAME Hazard Material Survey Ground Level
218 W Schaumburg Rd Schaumburg, IL 60194
Village of Schaumburg 714 South Plum Grove Rd
Shaumburg, Il 60193
Site Detail Map
FIGURE
05/07/2026
AV
T265663
DATE
DRAWN BY
PROJECT NO.
DRAWING TITLE
1A Project Area ACM Sample Locations
DRIVEWAY
<<ASPHALT>>
<<GRASS>>
AutoCAD SHX Text
SCALE IN FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Trusted Partner. Leading Environmental Solutions.
| T265663_Fig1A.pdf |
| Sheets and Views |
| T265663-1A (8.5x11) |
File details come from the government source that posted it. Updated .