Enclosure 60 - SSPC - Surface_Preparation_Standards.pdf

PDF 94 KB Posted

Attached to
Brandy Station Shipyard Repair Services
Solicitation number
W912PM23Q0042
Issued by

About this file

This document provides surface preparation standards for coating applications on various substrates. It outlines standards from the Society for Protective Coatings (SSPC) and National Association of Corrosion Engineers (NACE) for cleaning steel, galvanized metal, aluminum, pre-finished metal, stainless steel, non-ferrous metals, plastic, concrete and previously painted surfaces. The standards include solvent cleaning (SSPC-SP1), hand tool cleaning (SSPC-SP2), power tool cleaning (SSPC-SP3 and SSPC-SP11), brush-off blast cleaning (SSPC-SP7/NACE 4), commercial blast cleaning (SSPC-SP6/NACE 3), near-white blast cleaning (SSPC-SP10/NACE 2), and white metal blast cleaning (SSPC-SP5/NACE 1). It also provides standards for high- and ultrahigh-pressure water jetting (SSPC-SP12/NACE 5) and surface preparation of concrete (SSPC-SP13/NACE 6). The document relates to the federal contract opportunity for repair services at the Brandy Station Shipyard, solicited by the Army Corps of Engineers District Wilmington under number W912PM23Q0042.

View the file

Other files

File Type Posted
A22 - Questions_ Answers II.pdf PDF
A22 - Questions_Answers.pdf PDF
A2 - AMDT 0002 Revised Solicitation PWS_BS_SHIPYARD (5yr ABS).pdf PDF
A21 - W912PM23Q0042 AMDT0002.pdf PDF
A22 - Q_A Attchmt 13228E0896 - Aft Anchor Handling Arr and Details.pdf PDF
A21 - W912PM23Q0042 AMDT0002 CC.pdf PDF
A2 - Revised Solicitation PWS_BS_SHIPYARD (5yr ABS).pdf PDF
A21 - W912PM23Q0042 AMD 0001.pdf PDF
A21 - W912PM23Q0042 AMD 0001 CC.pdf PDF
Enclosure 34 - 13228E0935 - 151-175 - LCU Label Plate Book.pdf PDF
Enclosure 42 - 13230E5604 - 5 Blade Skewed Propeller.pdf PDF
Enclosure 49 - Duramax dwg 837002550.pdf PDF
Enclosure 63 - TM-55-1905-223-10 - Ops Man.pdf PDF
Enclosure 45 - Duramax drawing 837002549.pdf PDF
Enclosure 39 - 13228E0935 - 276-300 - LCU Label Plate Book.pdf PDF
Enclosure 2 - 13228E0811 Sea Chest Arr and Details.pdf PDF
Enclosure 47 - Duramax dwg 837002548.pdf PDF
Enclosure 44 - Duramax drawing 837002548.pdf PDF
Enclosure 22 - 13228E0898 - Boat Stowage and Handling and Misc Davit Arr and Det.pdf PDF
Enclosure 7 - 13228E0825 - Main Engine and Generator Installation and Details.pdf PDF
Enclosure 26 - 13228E0918 - Standard Welding Details.pdf PDF
Enclosure 17 - 13228E0884 - Diesel Eng FW Cooling Sys Piping Arrangement (Mn Engine and SSDG).pdf PDF
A21 - W912PM23Q0042.pdf PDF
Enclosure 3 - 13228E0812 - Scantling Sections and Transverse Bulkheads.pdf PDF
Enclosure 66 - TM-55-1905-223-24-11 - Marine Sanitation Device (MSD).pdf PDF
Enclosure 9 - 13228E0829 - Machinery Arrangement Below Main Deck.pdf PDF
A2 - Solicitation PWS_BS_SHIPYARD (5yr ABS)_19September2023.pdf PDF
Enclosure 53 - LCU2K-00-593-01 REV E.pdf PDF
Enclosure 58 - NAVSEA standard S 9086-CH-STM-010 CH 074 vol 1.pdf PDF
Enclosure 11 - 13228E0834 - Sea Water Cooling Piping Diagrammatic Arr.pdf PDF
Enclosure 48 - Duramax dwg 837002549.pdf PDF
Enclosure 15 - 13228E0881 - Bilge Ballast and Fire Main Diagrammatic Arr.pdf PDF
Enclosure 12 - 13228E0835 - Propulsion and SSDG Exhaust Piping Diagram.pdf PDF
Enclosure 54 - LCU2K-01-568-02 REV C.pdf PDF
Enclosure 65 - TM-55-1905-223-24-2 - Main Reduction Gear (MRG).pdf PDF
Enclosure 52 - Fernstrum Keel Cooler-Installation-and-Maintenance-Manual.pdf PDF
Enclosure 29 - 13228E0935 - 026-050 - LCU Label Plate Book.pdf PDF
Enclosure 10 - 13228E0832 - Shafting Arrangement.pdf PDF
Enclosure 64 - TM-55-1905-223-24-1 - Main Propulsion Engine (MPE).pdf PDF
Enclosure 1 - 13228E0803 - General Arrangement - Below Main Deck.pdf PDF
Enclosure 16 - 13228E0882 - Oily Water Separator System Diagrammatic Arr.pdf PDF
Enclosure 56 - LCU2K-99-531-01 Rev F.pdf PDF
Enclosure 14 - 13228E0880 - Sewage and Plumbing Diagrammatic Arrangement.pdf PDF
Enclosure 27 - 13228E0928 - Hyd Oil Piping Diagrammatic Arrgmt.pdf PDF
Enclosure 19 - 13228E0889 - Fire Monitor and Washdown Diagrammatic Arr.pdf PDF
Enclosure 36 - 13228E0935 - 201-225 - LCU Label Plate Book.pdf PDF
Enclosure 5 - 13228E0815 - Shell Expansion.pdf PDF
Enclosure 50 - DURAMAX Keel Cooler Installation Manual.pdf PDF
Enclosure 35 - 13228E0935 - 176-200 - LCU Label Plate Book.pdf PDF
Enclosure 8 - 13228E0826 - Bow Thruster Installation and Details.pdf PDF
Show 40 more

Latest 50 of 77 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SURFACE PREPARATION STANDARDS

Your coatings supplier will always designate the degree of surface preparation required for the materials you are using. The basic standards for preparing metal substrates are a joint effort between the Society for Protective Coatings (SSPC) and the National Association of Corrosion Engineers International

(NACE).

SSPC-SP1 Solvent Cleaning Removal of all visible oil, grease, soil, drawing and cutting compounds, and other soluble contaminants from steel surfaces with solvent, vapor, cleaning compound, alkali, emulsifying agent, or steam.

SSPC-SP2 Hand Tool Cleaning Removes all loose mill scale, loose rust, loose paint, and other loose detrimental foreign matter by hand chipping, scraping, sanding, and wire brushing.

SSPC-SP3 Power Tool Cleaning Removes all loose mill scale, loose rust, loose paint, and other loose detrimental foreign matter by power wire brushing, power sanding, power grinding, power tool chipping, and power tool descaling.

SSPC-SP5 / NACE 1 White Metal Blast Cleaning When viewed without magnification, the surface shall be free of all visible oil, grease, dust, dirt, mill scale, rust, coating, oxides, corrosion products and other foreign matter.

SSPC-SP6 / NACE 3 Commercial Blast Cleaning When viewed without magnification, the surface shall be free of all visible oil, grease, dust, dirt, mill scale, rust, coating, oxides, corrosion products and other foreign matter of at least 66-2/3% of unit area, which shall be a square 3 in. x 3 in. (9 sq. in.). Light shadows, slight streaks, or minor discolorations caused by stains of rust, stains of mill scale, or stains of previously applied coating in less than 33-1/3% of the unit area is acceptable.

SSPC-SP7 / NACE 4 Brush-Off Blast Cleaning When viewed without magnification, the surface shall be free of all visible oil, grease, dirt, dust, loose mill scale, loose rust, and loose coating. Tightly adherent mill scale, rust, and coating may remain on the surface. Mill scale, rust, and coating are considered tightly adherent if they cannot be removed by lifting with a dull putty knife.

SSPC-SP10 / NACE 2 Near-White Blast Cleaning When viewed without magnification shall be free of all visible oil, grease, dust, dirt, mill scale, rust, coating, oxides, corrosion products and other foreign matter of at least 95% of each unit area. Staining shall be limited to no more than 5 percent of each unit area, and may consist of light shadows, slight streaks, or minor discolorations caused by stains of rust, stains of mill scale, or stains of previously applied coatings. Unit area shall be approximately 3 in. x 3 in. (9 sq. in.).

SSPC-SP11 Power Tool Cleaning to Bare Metal When viewed without magnification, the surface shall be free of all visible oil, grease, dirt, dust, mill scale, rust, paint, oxides, corrosion products, and other foreign matter. Slight residues of rust and paint may be left in the lower portion of pits if the original surface is pitted. The surface profile shall not be less than 1 mil (25 microns).

K7OPNMSA

Highlight

SSPC-SP12 / NACE 5 Surface Preparation and Cleaning of Steel and Other Hard Materials by High- and Ultra High- Pressure Water Jetting Prior to Recoating This standard requires water jetting at high- or ultra high-pressure to prepare a surface for recoating using pressure above 10,000 psi. Water jetting will not produce a profile; rather, it exposes the original abrasive-blasted surface profile. Water jetting shall be performed to meet four conditions: WJ-1, WJ-2, WJ-3, and WJ-4, and a minimum acceptable surface shall have all loose rust, loose mill scale, and loose coatings uniformly removed.

SSPC-SP13 / NACE 6 Surface Preparation of Concrete Provides requirements for surface preparation of concrete by mechanical, chemical, or thermal methods prior to the application of bonded protective coating or lining systems.

SSPC-SP14 / NACE 8 Industrial Blast Cleaning Removal of all visible oil, grease, dust and dirt, when viewed without magnification. Traces of tightly adherent mil scale, rust, and coating residues are permitted to remain on 10% of each unit area of the surface if they are evenly distributed. Shadows, streaks, and discoloration caused by stains of rust, stains of mill scale, and stains of previously applied coating may be present on the remainder of the surface.

WATER JETTING STANDARDS

SSPC-SP12 / NACE 5

Surface Preparation and Cleaning of Steel and Other Hard Materials by High- and Ultra High- Pressure Water Jetting Prior to Recoating

This standard requires water jetting at high- or ultra high-pressure to prepare a surface for recoating using pressure above 10,000 psi. Water jetting will not produce a profile; rather, it exposes the original abrasive-blasted surface profile. The specifier shall use one of the visual surface preparation definitions (WJ-1 to WJ-4) and one of the non-visual surface preparation definitions (SC-1 to SC-3) to specify the degree of visible and non-visible surface matter to be removed.

Pressure Categorization

Low-Pressure Water Cleaning (LP WC) Cleaning performed at pressures less than 34 Mpa (5,000 psi)

High-Pressure Water Cleaning (HP WC) from 34 to 70 Mpa (5,000 to 10,000 psi)

High-Pressure Water Jetting (HP WJ) from 70 to 170 Mpa (10,000 to 25,000 psi)

Ultrahigh-Pressure Water Jetting (UHP WJ) above 170 Mpa (25,000 psi)

Visual Conditions of Surface Cleanliness

WJ-1

Surface shall be free of all previously existing visible rust, coatings, mill scale, and foreign matter and have a matte metal finish

WJ-2

Surface shall be cleaned to a matte finish with at least 95% of the surface area free of all previously existing visible residues and the remaining 5% containing only randomly dispersed stains of rust, coatings, and foreign matter

WJ-3

Surface shall be cleaned to a matte finish with at least two-thirds of the surface area free of all previously existing visible residues (except mill scale), and the remaining one-third containing only randomly dispersed stains of previously existing rust, coatings, and foreign matter

WJ-4

Surface shall have all loose rust, loose mill scale, and loose coatings uniformly removed

Non-Visual Conditions of Surface Cleanliness

SC-1

Surface shall be free of all detectable levels of contaminants as determined using available field test equipment with sensitivity approximating laboratory test equipment. For purposes of this standard, contaminants are water-soluble chlorides, iron-soluble salts, and sulfates

SC-2

Surface shall have less than 7 g/cm2 chloride contaminants, less than 10 g/cm2 of soluble ferrous ion levels, and less than 17 g /cm2 of sulfate contaminants as verified by field or laboratory analysis using reliable, reproducible test equipment

SC-3

Surface shall have less than 50 g/cm2 chloride and sulfate contaminants as verified by field or laboratory analysis using reliable, reproducible test equipment

K7OPNMSA

Highlight

K7OPNMSA

Highlight

SURFACE PREPARATION BY SUBSTRATE

Iro n or S te el

G al va ni ze d

Al um in um

Pr e-

Fi ni sh ed

M et al s

S ta in le ss S te el

No n-

Fe rr ou s

M et al s

P la st ic

P

VC

/F

R P

Co nc re te

P re vi ou sl y

Pa in te d

Su rfa ce s

SSPC-SP1

Solvent Cleaning X X X X X X X X

SSPC-SP2

Hand Tool Cleaning X X

SSPC-SP3

Power Tool Cleaning X X X

SSPC-SP11

Power Tool Cleaning to Bare Metal X

SSPC-SP7/NACE 4

Brush-Off Blast Cleaning X X X X X X X X

SSPC-SP14/NACE 8

Industrial Blast Cleaning X

SSPC-SP6/NACE 3

Commercial Blast Cleaning X

SSPC-SP10/NACE 2

Near-White Blast Cleaning X

SSPC-SP5/NACE 1

White Metal Blast Cleaning X

SSPC-SP12/NACE 5

High- and Ultrahigh-Pressure Water Jetting Prior to Recoating

X X X X X

SSPC-SP13/NACE 6

Surface Preparation of Concrete X

Concrete can also be cleaned and prepared using ASTM D 4260 (Acid Etch – Floors), ASTM D 4258 (Solvent Cleaning), ASTM D 3359 (To Check Adhesion), and ASTM D 4259 (To Abrade Concrete).

File details come from the government source that posted it. Updated .