Enclosure 2 Fire System Details.docx
DOCX document 14 KB Posted
- Solicitation number
- USCG-SPS-0001
About this file
This document appears to be Enclosure 2, which provides details on the fire system components for the federal contract opportunity. The key details are:
The fire system includes various panels (Hanger Panel, Supply Panel, Admin Panel, Pease Building Panel, Cutter Support Building 1 Panel, Cutter Support Building 2 Panel, Exchange Panel, Medical Panel, Pease building storage garages Panel) with a total of 55 fire detectors, 30 horns/strobes, 12 pull stations, and various fire extinguishers (ABC and CO2). The systems include sprinkler systems, clean agent systems, and AFFF systems.
The related federal contract opportunity is for Fire Suppression Systems Inspections for Port Angeles, WA, solicitation number USCG-SPS-0001, issued by the U.S. Coast Guard. It is a Small Business Set-Aside, with a Lowest Price Technically Acceptable evaluation criteria. The contract will be a Firm Fixed-Price award requiring the contractor to provide all personnel, equipment, transportation, tools, materials, supervision, and other items and services necessary for inspection, testing, and maintenance of the fire protection systems in accordance with NFPA standards.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 15-5545 Wage Determination.txt | TXT text file | |
| SOW_Scope of Work Fire System Inspection_2024.docx | DOCX document | |
| Enclosure 1 NFPA 409 Hangar Testing Chapter 11.docx | DOCX document | |
| Service-Clauses1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hanger Panel: 2 Simplex: one panel for fire detectors. One panel for deluge system.
Detectors: 55 Horns/ strobes: 30 Pull stations: 12 Sprinkler system: yes Fire extinguisher: ABC: 17 CO2: 5 Other extinguishing systems: clean agent system in AET shop, AFFF system for hanger Supply Panel: Honeywell Detectors: 1 Horns/ strobes: 4 Pull stations: 4 Sprinkler system: yes Fire extinguisher: ABC: 2 Other extinguishing systems: two Halon system in hazmat storage area Admin Panel: Honeywell Detectors: 17 Horns/ strobes: 5 Pull stations: 4 Sprinkler system: no Fire extinguisher: ABC: 6 Pease Building Panel: Siemens Fike Detectors: 46 Horns/ strobes: 4 Pull stations: 4 Sprinkler system: yes Fire extinguisher: ABC: 13 CO2:1 Other extinguishing systems: clean agent system in server room
Cutter Support Building 1 Panel: Simplex Detectors: 9 Horns/ strobes:3 Pull stations:3 Sprinkler system: yes Fire extinguisher: ABC: 4 Cutter Support Building 2 Panel: Edward System Technology Detectors: 9 Horns/ strobes: 3 Pull stations: 3 Sprinkler system: yes Fire extinguisher: ABC: 4 Exchange Panel: Honeywell Detectors: 23 Horns/ strobes: 2 Pull stations: 1 Sprinkler system: yes Fire extinguisher: ABC: 4 Medical Panel: Edward System Technology Detectors: 30 Horns/ strobes: 4 Pull stations: 4 Sprinkler system: yes Fire extinguisher: ABC: 5 CO2: 1 Pease building storage garages Panel: Honeywell Detectors: 7 Horns/ strobes: 1 Pull stations: 2 Sprinkler system: no Fire extinguisher: ABC:8 Other Fire extinguisher: ABC: 19
File details come from the government source that posted it. Updated .