This is a Requirements List for an E-Field Generator procurement. The Naval Surface Warfare Center Dahlgren Division (NSWCDD) is soliciting a single unit of a Commercial-off-the-Shelf (COTS) or modified COTS E-Field Generator through Request for Quotation (RFQ) N0017826Q6731. The solicitation is issued under full and open competition using simplified acquisition procedures for commercial items per FAR Part 12. The anticipated publication date is April 30, 2026, with a closing date of May 12, 2026. The contract will be awarded on a firm fixed-price basis with no additional costs permitted after award; all expenses including shipping to Dahlgren, VA, tariffs, and duties must be included in the quoted price.

The E-Field Generator must meet specific technical requirements including the capability to generate electromagnetic fields between 10 kHz and 30 MHz with both electric and magnetic field components, electric field strength of 10 V/m to 200 V/m within 1 meter, and continuous power handling rated for up to 2,500 watts. The equipment must feature a 7-16 DIN input connector, wheels for mobility, and physical dimensions not exceeding 105 inches in length and 49 inches in depth, with a fully assembled height capable of lowering to or below 77 inches. Repair and calibration support must be provided from a U.S.-based facility to ensure rapid turnaround and efficient technical communication. Vendors must supply a data sheet demonstrating electric field patterns in both vertical and horizontal polarization. The NAICS code is 334515 and the PSC/FSC code is 5985 (Antennas, waveguides, and related equipment).

View the file

Other files

File Type Posted
Solicitation - N0017826Q6731.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Description tc={6588DC3A-7687-4DC6-9695-74F5FA189CD4}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

Add configuration if needed Quantity Unit of Measure (UoM) tc={BF209D72-D179-4ADC-944C-17C4C54B5D46}: [Threaded comment]

Your version of Excel allows you to read this threaded comment; however, any edits to it will get removed if the file is opened in a newer version of Excel. Learn more: https://go.microsoft.com/fwlink/?linkid=870924

Comment:

Add license period for renewals Manufacturer

REQUIREMENTS LIST
ItemSpecificationsQuantityUnit
E-Field GeneratorCapable of generating electromagnetic fields between 10 kHz-30 MHz (field must have both electric and magnetic field component)1Each
Electric field strength capable of generating 10 V/m to 200 V/m within 1 meter
Power handling rated to handle continuous input power up to 2500 watts
Input connector: 7-16 Din
Equipped with wheels
Physical dimensions:

Maximum length of 105 in. and depth of 49 in.

Fully assembled system must be able to lower its height to or below 77 in.

Repair and calibration support from U.S.-based facility (to ensure rapid turnaround times essential for Fleet support and to allow for efficient technical communication during standard business hours)
Data sheet showing the electric field across the antenna (vertical polarization) and above/below (horizontal polarization)
Must be a Commercial-off-the-Shelft (COTS) product or modified COTS product

Add configuration if needed

Add license period for renewals