DWG-OEH8.pdf
PDF 293 KB Posted
- Attached to
- Water Service Line Boynton, OK Federal contract opportunity
- Solicitation number
- 246-24-Q-0199
About this file
This document is a Request for Quotes (RFQ) for a Water Service Line project in Boynton, Oklahoma. The Indian Health Service is issuing this 100% Indian-owned set-aside procurement under NAICS code 237110, with a size standard of $45 million.
The contractor shall furnish and install a Water Service Line as shown in the drawings and statement of work. The period of performance is 60 calendar days from the Notice to Proceed. The estimated price is less than $25,000. Quotes will be evaluated on an acceptable/non-acceptable basis, starting with the lowest price. To be considered, quotes must include a firm, fixed-price quote, technical specifications meeting the statement of work, and two relevant past performance references. The official site visit is scheduled for August 16, 2024, and questions are due by August 22, 2024. Quotes are due by August 30, 2024. Award will be made to the responsible, responsive offeror with the lowest reasonable price that meets all technical specifications.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| IHS IEE Representation Form_Jan 2022_508 Compliant.pdf | ||
| SF18-95a RFQ and Clauses.pdf | ||
| ok33 (1).txt | TXT text file | |
| Bid Sheet WSL.xlsx | XLSX spreadsheet | |
| SOW WSL HDPE.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IN
D
IA
N
HEA LTH SER
V
ICE
1 9 5 5
Sanitation Facilities Design & Location
Community On-Site Sewer
Project # OK19-F22 County:
Name:
Cistern Pump Well Depth On -Site Water Community Water Name: Muskogee County RWD #3 Septic Tank Lagoon Drain field
Directions To Site:
Project Description:
Property Description:
Address:
Capacity: Shape: Material:
Make Model Motor Size Casing Depth Diameter Material
Yield S.W.L. Drawdown Drilled By: Date Drilled:
Capacity Shape Material
Total Depth: Length: Width:
Trench Length: Trench Width: Material:
# Of Bedrooms
Name Profile By: Andrew Banta Profile Date: 4/25/24
As-Built Proposed
Drawn By:
Reviewed By:
Approved By:
Name Date
OEH & E Field Office Indian Health Service P.O. Box 67 Okmulgee, Ok 74447 Work#: (918)-586-8420
SR # Latitude: Longitude:
AFB 7/26/24
Property is 14 mile north of Council Hill on HWY 72 on WSOR. Steel gated entry.
Sam Stamper 918-527-2326 Muskogee Tract in NW/4 Sec 31 T13N R16E
6704 35.5602723 (N) -95.6585782 (W)
13563 S HWY 72, Boynton, OK 74422
OEH-8 (8/93)
CW & IS
Tract in NW/4 Sec 31 T13N R16E, Muskogee Co.
Aerobic Spray Aerobic Drip
Pump Tank: 700 Pump Tank
Required Spray Area (ft2): 6,068 Drip Line
Designed (ft2): 7,696
1"=500'
Property Line
Note:
Property is 58 Acres Homeowner will connect WSL to meter
Proposed Valve and Valve Box
Proposed 2,000 LF of 2" DR11 HDPE Water Service Line
Proposed Aerobic System w/ 2-35'
Spray Heads
New Construction
Home
| Sheets and Views |
| Layout1 |
File details come from the government source that posted it. Updated .