DWG_0356_Locking Pellet Installation Torque Testing Procedure for Non-DoD Entities.pdf
PDF 89 KB Posted
- Attached to
- Naval Foundry and Propeller Center CLB K -Monel Component Procurement Federal contract opportunity
- Solicitation number
- N6449822Q4034
About this file
This technical drawing provides instructions for non-Department of Defense entities to install locking pellets and conduct torque testing on threaded fasteners. Entities must manufacture pellets to a light interference fit and cut them flush with the fastener thread. Quality assurance inspectors must verify pellet size and witness on-site torque tests, where fasteners must exceed the minimum breakaway torque specified. Fasteners failing tests may be retested once before disqualification. Threads cannot show damage or pellet hole elongation.
The related federal contract opportunity solicits proposals to produce Monel components per applicable drawings. The Naval Sea Systems Command seeks a contractor to manufacture various components fully compliant with part drawings and required contract data requirements lists. The contractor must produce the items in accordance with the scope of work.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| (UNCLASS-DISTR C)_C24543003 Rev A_CLB Class DP2.3.X Nut Cap Attachment Fastener_SIGNED SEA05P3.pdf | ||
| CLB K-Monel Component Procurement - CDRL A002 - Contract Status Report_Signed.pdf | ||
| CLB K-Monel Component Procurement - CDRL A001 - Certification Package_Signed.pdf | ||
| UNCLASS DISTR_C_C24541102 REV A DP2.3.X HUB FLANGE FASTENER_A3u_PTIsigned05P3 Signed.pdf | ||
| CLB K-Monel Component Procurement - CDRL A003 - GovtPropertyInventoryReport_Signed.pdf | ||
| Request for Quote (RFQ) N6449822Q4034.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NO. TITLE IDENT
REFERENCES
DISTRIBUTION STATEMENT A
APPROVED FOR PUBLIC RELEASE
DISTRIBUTION IS UNLIMITED
UNITS AND TOLERANCES DEPARTMENT OF THE NAVY
NORFOLK NAVAL SHIPYARD DETACHMENT
NAVAL FOUNDRY AND PROPELLER CENTER
PHILADELPHIA, PA
Locking Pellet Installation & Torque Testing Procedure for Non-DoD
Entities
PREPARED
Brett Pierce
DATE
11/4/19 SIZE CODE IDENT: NFPC DRAWING NO. REV
CHECKED
Chris Clark
11/4/19 A CODE
1420 0356 - PROJECT ENG
Chris Clark
11/4/19
APPROVED
Nate Bird
See Digital
Signature
SCALE: None SHEET 1 OF 2
N/A
REVISIONS
REV ZONE DESCRIPTION DATE APPROVED
- N/A INITIAL RELEASE See Digital Signature
Purpose:
This drawing provides instructions for installation of self-locking pellet and torque testing of threaded fasteners by Non-DoD Entities. Instructions per this drawing are in accordance with requirements of UIPI 5050-904B
Pellet Installation & Torque Testing Procedure:
1. The vendor shall manufacture a locking pellet in accordance with the applicable drawing or contract.
Pellet must be sized to create a light interference fit with the pellet hole.
2. The vendor shall install a pellet in each fastener.
3. The vendor shall use a sharp knife to cleanly cut the locking pellet approximately flush with the fastener thread major diameter.
4. The vendor shall measure the fastener diameter at the pellet. This diameter must be of the size and within the tolerance given in the applicable drawing or contract. Quality Assurance Inspectors from the Naval Foundry and Propeller Center must be on-site at the vendor’s location to verify the results.
5. The vendor shall perform a torque test on all pelletized fasteners as follows:
a) Insert the fastener into an appropriate nut or test fixture until the pellet is fully engaged. The threads of the nut/test fixture shall be of the same nominal size and thread class as the fastener being tested.
b) Using a calibrated torque wrench, measure the breakaway torque required to remove the fastener.
The required minimum breakaway torque value will be given in in the applicable drawing or contract.
Quality Assurance Inspectors from the Naval Foundry and Propeller Center must be on-site at the vendor’s location to witness the tests.
Note: If a test proves unsatisfactory for these requirements, remove the pellet, inspect the part for damage, install a new pellet in accordance with this procedure and retest the fastener. This retest may be performed once before disqualifying the part.
6. Inspect the fastener threads for any damage. Noticeable distortion or scratches deep enough to reduce the efficiency of the threads, or any elongation of the pellet hole, shall be considered a failure of the self– locking element.
SIZE CODE IDENT CODE 1420 DRAWING NO. REV
A
CODE 1420
0356 - SCALE: None SHEET 2 OF 2