Dura-Ramp_I_(DR-I)_Gangway_Technical_Data_Sheet.pdf

PDF 1 MB Posted

Attached to
D6 Ringtail Courtesy Dock Replacement Federal contract opportunity
Solicitation number
127EAU24Q0127
Issued by
Department of Agriculture Forest Service

About this file

This document is a technical data sheet for the Dura-Ramp I (DR-I) Gangway, a product offered by Gator Dock & Marine, LLC and Mantle Industries, LLC, subsidiaries of CMI Limited Co.

The data sheet provides specifications for the gangway, including a maximum length of 80 feet, a maximum width of 8 feet, a standard live load capacity of 50 psf, and an occasional vehicle load capacity of up to 2,500 lbs. It notes that longer span gangways may require a different truss configuration. The gangway is constructed from 6061-T6 aluminum and is designed to meet ASCE 7/IBC wind load requirements and AASHTO/International Building Code criteria. Standard features include slip-resistant aluminum decking, mid-rail, toe rail, and 36" ADA grab rail. Premium color, texture, railing, and decking options are available.

The related federal contract opportunity is for the purchase of an aluminum courtesy floating dock replacement for the Ringtail Launch Site on Lake Roosevelt, to be issued by the U.S. Department of Agriculture Forest Service.

View the file

Other files for this federal contract opportunity

Other files attached to D6 Ringtail Courtesy Dock Replacement, newest first.
File Type Posted
Poly-Tub_Float_Dock_Technical_Data_Sheet-Vendor.pdf PDF
Warren_Gangway_Technical_Data_Sheet-Vendor.pdf PDF
NRE_RFQ_Comb_Solic_Floating_Dock_Solicitation.pdf PDF
1131491_FS-Schedule_of_Items_-_Need_Price.xlsx XLSX spreadsheet
Spec.docx DOCX document
Sol_127EAU24Q0127.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

cmilc.com 1-800-256-8857 up to 80'Maximum Length (L)1

Maximum Width (W) up to 8'

Not RatedStandard Wind Speed2

Structural Material 6061-T6 Aluminum (Recycled Billet)

Standard Live Load4 50psf

Max Occasional Vehicle Load up to 2,500lbs

1 Spans longer than 80' are possible and require evaluation to determine feasibility. Longer span gangways may require a slightly different truss configuration than the one shown here.

2 Floor framing can be designed to meet project specific ASCE 7/IBC wind load requirements, if needed.

3 Premium color & texture options are available.

4 Under certain circumstances, gangway can be designed to support project specific live loads greater than 50psf for shorter spans. Further evaluation would be required.

5 Gangway can be designed per AASHTO and/or International Building Code criteria upon customer request.

6 Combination rail, toe rail, horizontal guard rail, cable rail, mesh panel, 36" ADA grab rail, and custom rail options are available. Toe rail and 36"ADA grab rail shown here.

7 Premium decking options are available.

Standard Design Codes5

Aluminum Design Manual

AWS D1.2 Structural Welding Code -

Aluminum

Other Standard Gangway Styles

Dura-RampTM II (DR-II) Warren

DURA-RAMPTM I (DR-I)

GANGWAY

W

Standard Railing6 Mid Rail

Standard Decking7 Slip-Resistant Aluminum 9" Deck Planks

Standard Color & Texture3 Mill Finish Aluminum

Gator Dock & Marine, LLC and Mantle Industries, LLC are wholly owned subsidiaries of CMI Limited Co.

Visit cmilc.com/legal for more information on referenced trademarks and patents owned by CMI Limited Co.

L

Updated: March 27, 2023

© Copyright 2023 - CMI