DRM 2024-57 No 8 MCI Framingham Addendum 1.pdf
PDF 3 MB Posted
- Solicitation number
- BD-25-1025-DOCFS-9815-111148
- Issued by
- Middlesex County, Massachusetts
About this file
This is Addendum No. 1 to bid solicitation DRM 2024-57 #8 issued by the Massachusetts Executive Office of Public Safety and Security, Department of Correction, Division of Resource Management for an Emergency Notification System at MCI Framingham in Framingham, MA. The addendum modifies the specifications with four items: 1) The contractor must install communication cable between the alert beacon and LED marquee in rigid conduit to prevent tampering, 2) One CAT6 cable must be run to rapid response console locations and terminated on a red colored jack using a single gang bell box with security bit screws, 3) The contractor must incorporate work related to specification section 02 80 00, and 4) The contractor must follow recommendations from the attached asbestos and RCRA-8 paint survey report dated January 30, 2025.
The addendum includes detailed information about asbestos-containing materials (ACMs) and RCRA-8 metals found in paint throughout the facility, based on testing performed by Arcadis U.S. Inc. The survey identified ACMs in floor tiles and associated mastics in various buildings, with chrysotile content ranging from <1% to 3%. RCRA-8 metals testing of paint samples revealed detectable levels of various metals including lead, chromium, cadmium and others, requiring specific handling and disposal procedures as outlined in specification section 02 80 00. The report includes detailed requirements for worker protection, containment controls, work procedures, air sampling, clean-up and waste disposal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid Intent Form~28.doc | DOC document | |
| Bidder Checklist~64.doc | DOC document | |
| Prevailing Wage Payroll Report Form~74.pdf | ||
| Updated Plan Holders List~4.docx | DOCX document | |
| Prevailing Wage Statement of Compliance~73.pdf | ||
| SDP plan form 3 - reporting~46.xlsx | XLSX spreadsheet | |
| Bid Results~62.doc | DOC document | |
| Bid Package~2.pdf | ||
| Where to get plans and specs~50.docx | DOCX document | |
| Site Visit Sign in Framingham.pdf | ||
| Prevailing Wages~32.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRM 2024-57 #8
Addendum No. 1
COMMONWEALTH OF MASSACHUSETTS
EXECUTIVE OFFICE OF PUBLIC SAFETY AND
SECURITY
DEPARTMENT OF CORRECTION
DIVISION OF RESOURCE MANAGEMENT
DRM 2024-57 #8
Emergency Notification System MCI Framingham
Framingham, MA
January 31, 2025
ADDENDUM No. 1
The attention of bidders submitting proposals for the subject project at MCI
Framingham, located in Framingham, MA, is called to the following addendum to the Specifications and or Drawings. The items set forth herein, whether of omission, addition, substitution, or clarification are all to be included in and form a part of the proposal submitted.
A: SCOPE MODIFICATION AND ADDITIONAL CLARIFICATION
ITEM NO. DESCRIPTION
Item #1. Attention is directed to Appendix D, LED Marquee Installation Guide. In
Section 4.4, with regard to the communication cable between the alert beacon and the LED marquee, the contractor shall be responsible for installing the cable between these two devices.
This cable shall be installed in rigid conduit to prevent tampering. The contractor is responsible for installing the rigid conduit per the specifications.
Item #2. At the rapid response console locations, the contractor shall homerun one (1)
CAT6 cable to these locations. The contractor shall terminate these cables on a red colored jack, using a single gang bell box that is 2 5/8” deep with a stainless-steel dual port faceplate fastened with security bit screws.
Item #3. The contractor shall incorporate all work related to the attached specification section 02 80 00 into their scope of work.
Item #4. The contractor shall incorporate attached Path of Construction Asbestos and
RCRA-8 Paint Survey Report for MCI Framingham prepared by Arcadis U.S., Inc. dated January
30th, 2025. The contractor shall follow all recommendations contained in the above-mentioned report and all applicable OSHA Safety and Health Regulations.
Arcadis U.S., Inc.
One Federal Street
Suite 3800
Boston, Massachusetts 02110 www.arcadis.com
Page:
1/5
Mr. Steve Lemmo
Massachusetts Department of Correction
Division of Resource Management
50 Maple Street Milford, Massachusetts 01757
Subject:
Path of Construction Asbestos and RCRA-8 Paint Survey Report
Emergency Notification System Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01701
Dear Mr. Lemmo:
Arcadis U.S., Inc. (Arcadis) conducted a path of construction (POC) Asbestos and
Resource Conservation and Recovery Act (RCRA) 8 metals in paint survey at MCI
Framingham located at 99 Loring Drive in Framingham, Massachusetts (site).
The survey included an inspection of the following areas:
Old Administration Building
Townline Building
Laurel Building
HSU Building
Smith Building
The objective of the survey was to ascertain the general presence and location of asbestos-containing materials (ACMs) and RCRA-8 metals in paint that may be impacted during the planned Emergency Notification System installation project.
On January 22, 2025, Mr. Brandon Wabble with Arcadis visited the site to conduct the survey. A copy of his asbestos accreditations is provided in Attachment A.
ENVIRONMENT
Date:
January 30, 2025
Contact:
Gregory Donovan
Phone:
617.778.8212
Email:
greg.donovan@arcadis.com
Our ref:
30263340 arcadis.com
Mr. Steve Lemmo
January 30, 2025
Page:
2/5
Asbestos-Containing Materials Survey
Asbestos Survey Methodology
Arcadis conducted the path of construction asbestos survey for compliance with the United States
Environmental Protection Agency (USEPA) National Emissions Standards for Hazardous Air Pollutants
(NESHAPs), Occupational Safety and Health Administration (OSHA) Asbestos in General Industry
Standard (29 CFR 1910.1001), OSHA Asbestos in Construction Standard Title 29 CFR Part 1926.1101, the Massachusetts Department of Environmental Protection 310 CMR 7.15, and the Massachusetts
Department of Labor Standards 454 CMR 28.00.
This was accomplished by initially conducting a visual inspection of the planned path of construction areas then collecting samples of suspect ACM based on these observations. Arcadis conducted the asbestos survey in general accordance with ASTM International (ASTM) E2356 Standard Practice for
Comprehensive Building Asbestos Surveys. ASTM E2356 meets the applicable requirements of current
USEPA NESHAP Standard 40 Code of Federal Regulations (CFR) 61, Subpart M (Asbestos), USEPA
Asbestos Hazard Emergency Response Act (AHERA) 40 CFR 763, Subpart E, and Occupational Safety and Health Administration (OSHA) asbestos survey and/or sampling regulations.
The survey included an inspection of the areas within the POC providing a general sense of the overall location, type, quantity, and condition of suspect ACMs present. It was thorough in that most accessible functional spaces were inspected, and bulk samples taken of suspect materials observed.
Suspect materials were divided into "Homogeneous Areas" (HAs) (i.e., building materials that were determined by the inspector to be homogeneous based on their color, texture, and assumed date of installation). A representative number of samples were collected from each HA.
Bulk material samples were collected and assigned their own unique identification number, placed in 4-mil plastic bags, and tightly sealed for transport under a chain-of-custody protocol to EMSL Analytical, Inc. in
Indianapolis, Indiana.
Asbestos Analytical Methodology
Bulk samples were analyzed for asbestos (reported in percent of type of asbestos) using Polarized Light
Microscopy with Dispersion Staining (PLM/DS) in accordance with the USEPA Method 600/R-93/116.
Percentage estimates of each material's composition are based on the analyst's best visual judgment following PLM/DS analysis, and examination with a stereoscope.
EMSL is a member of the American Industrial Hygiene Association (AIHA), National Voluntary Laboratory
Accreditation Program (NVLAP). The laboratory analytical reports are provided as Attachment B.
January 30, 2025
Page:
3/5
Resource Conservation and Recovery Act 8 Paint Survey
RCRA-8 Metals Survey Methodology
Arcadis conducted a path of construction RCRA-8 metal in paint survey for compliance with USEPA RCRA
(Standard 40 CFR 240-280) and OSHA Safety and Health Regulations for Construction (Standard 29 CFR
1926).
Suspect RCRA-8 metal-containing paint was identified based upon a visual inspection of painted building components in the path of construction then collecting paint chip samples based on these observations.
Paint chip samples were collected and assigned their own unique identification number, placed in 4-mil plastic bags, and tightly sealed for transport under a chain-of-custody protocol to EMSL in Indianapolis, Indiana.
RCRA-8 Metals Analytical Methodology
Paint chip samples were analyzed for total metal content (reported in milligrams per kilogram [mg/Kg]) by
Inductively Coupled Plasma (ICP) Atomic Emission Spectrometry in accordance with USEPA Method
SW-846 3050B/6010D, and Mercury by Cold Vapor Atomic Absorption (CVAA) SW-846 7471B. EMSL conformed to QA/QC procedures established by their accreditation manual. The laboratory analytical reports are provided in Attachment C.
SURVEY FINDINGS
Asbestos
Arcadis identified thirty (30) HAs, of which, sixty-five (65) suspect ACM bulk samples were collected and submitted for laboratory analysis. Details regarding the material description, material location, condition, friability, asbestos content, and estimated quantity of each HA identified during the POC asbestos survey is presented in the Homogeneous Areas Summary Table provided in Table 1. Approximate sampling locations are shown on the Figures.
Massachusetts Department of Environmental Protection defines ACM as a material containing more than or equal to 1% asbestos by weight. The following HAs are confirmed ACM:
Old Administration Building
HA-12: 9” Beige with Black Streaks Floor Tile
HSU Building
HA-21: 9” Light and Dark Brown Patterned Floor Tile
HA-23: 9” Tan and Brown Floor Tile
The following HA has been determined to contain trace amounts of asbestos, i.e. one percent or less (1% or <1%) by laboratory analysis and their disturbance is regulated by OSHA:
HSU Building
HA-22: Black Mastic Associated with HA-21
January 30, 2025
Page:
4/5
The remaining bulk samples collected by Arcadis as part of the survey were reported by the laboratory as
“None Detected” for asbestos.
RCRA-8 Metals
Eight (8) composite RCRA-8 metals in paint chip samples were collected and submitted for laboratory analysis. Detectable concentrations of RCRA-8 metals were identified in the following paint chips collected:
RCRA-1: White/Beige/Blue Paint on Brick Walls in Old Administration Building
RCRA-2: White Paint on Gypsum Board Walls in Old Administration Building
RCRA-3: White Paint on Gypsum Board Walls in Old Administration Building
RCRA-4: Gray Paint on Brick Walls in Old Administration Building
RCRA-5: White Paint on Metal Ceiling in Townline Building
RCRA-6: Blue/White Paint on Concrete Walls in Laurel Building
RCRA-7: Gray/White Paint on Plaster Wall in Smith Building
RCRA-8: Gray/White Paint on Plaster Wall in Old Administration Building
Details regarding the sample description, sample location, analyte, and results are presented in the RCRA-8 Metals in Paint Summary provided in Table 2. Approximate sampling locations are shown on the Figures.
RECOMMENDATIONS
Asbestos-Containing Materials
As presented in Table 1, and the laboratory data provided in Attachment B, results of the asbestos survey identified confirmed ACMs at the site.
ACMs identified at the site that may be disturbed during construction activities, must be removed by a licensed asbestos abatement contractor utilizing industry standard work procedures in accordance with all federal, state, and local regulations governing asbestos.
If other suspect materials, not referenced in this survey report, are identified during construction activities, Arcadis recommends that these materials be considered ACM until they are inspected by an appropriately licensed asbestos inspector and proven otherwise.
Asbestos waste must be disposed at an asbestos waste receiving facility that is duly permitted by the state and/or local municipality in which it resides.
RCRA-8 Metals
As presented in Table 2, and the laboratory data provided in Attachment C, the results of the RCRA-8 metals in paint survey identified detectable concentrations of RCRA-8 metals in samples collected.
Arcadis recommends that the general contractor and any sub-trades be advised of the presence of
RCRA-8 metals in the paint and the requirements for compliance with RCRA Standards (Title 40 CFR 240-
280) and OSHA Safety and Health Regulations for Construction (Standard 29 CFR 1926). Compliance with OSHA is required for any detectable levels of metals in paint that may potentially be disturbed.
January 30, 2025
Page:
5/5
Any work that could disturb known or suspect RCRA-8 metal-containing paint should be conducted in a way to minimize and control dust, and the contractor should perform a thorough cleanup.
If other suspect paints, not referenced in this survey report, are identified during renovation or demolition activities, Arcadis recommends that these materials be managed as RCRA-8 metal-containing paint until they are sampled and proven otherwise.
Arcadis recommends that construction waste streams containing paint generated during the planned construction activities be tested via Toxicity Characteristic Leaching Procedure for waste disposal characterization prior to disposal.
CLOSING
Thank you for your time and consideration on this project. Please do not hesitate to call if you have questions regarding the results of this POC survey or if you require additional information.
Sincerely, Arcadis U.S., Inc.
Gregory Donovan
Certified Project Manager
TABLES
Table 1 Homogeneous Areas Summary
Table 2 RCRA-8 Metals in Paint Summary
FIGURES
A-01 HSU 1st Foor Sample Locations
A-02 HSU 2nd Floor Sample Locations
A-03 Laurel and Towline Sample Locations
A-04 Smith Building 1st Foor Sample Locations
A-05 Smith Building 2nd Foor Sample Locations
A-07 Old Administration Building 1st Floor Sample Locations
A-08 Old Administration Building 2nd Floor Sampe Locations
ATTACHMENTS
A Asbestos Accreditations
B Laboratory Analytical Report – Asbestos
C Laboratory Analytical Report – RCRA-8 Metals
January 30, 2025
Page:
6/5
TABLES
Table 1
Homogeneous Areas Summary
Emergency Notification System Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01757
HA No. Building Material Description Material Location Sample Number Condition Friability Asbestos
Content Notes
Old Administration
Building Gray Brick Mortar Floors 1-3 Throughout 1A, 1B Good Non-Friable NAD
Old Administration
Building Gypsum Board 3rd Floor Industries 2A, 2B Good Non-Friable NAD
Old Administration
Building
12" White with Black Streaks
Floor Tile 3rd Floor Industries 3A, 3B Good Non-Friable NAD
Old Administration
Building
Beige Mastic Associated with HA-
3rd Floor Industries 4A, 4B Good Non-Friable NAD
Old Administration
Building White Plaster Wall Skim Coat 3rd Floor Library 5A, 5B, 5C Good Non-Friable NAD
Old Administration
Building Gray Plaster Wall Base Coat 3rd Floor Library 6A, 6B, 6C Good Non-Friable NAD
Old Administration
Building White Gypsum Board 3rd Floor College Classroom 7A, 7B Good Friable NAD
Old Administration
Building 12" Beige Patterned Floor Tile 3rd Floor College Classroom 8A, 8B Good Non-Friable NAD
Old Administration
Building
Beige/Brown Mastic Associated with HA-8 3rd Floor College Classroom 9A, 9B Good Non-Friable NAD
Old Administration
Building White Plaster Wall Skim Coat 2nd Floor Cells 10A, 10B, 10C Good Non-Friable NAD
Old Administration
Building Gray Plaster Wall Base Coat 2nd Floor Cells 11A, 11B, 11C Good Non-Friable NAD
Emergency Notification System Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01757
HA No. Building Material Description Material Location Sample Number Condition Friability Asbestos
Content Notes
Old Administration
Building
9" Beige with Black Streaks
Floor Tile 2nd Floor CPO Hallway 12A, 12B Good Non-Friable 2% Chrysotile
Old Administration
Building
Black Mastic Associated with HA-
2nd Floor CPO Hallway 13A, 13B Good Non-Friable NAD
Old Administration
Building 12" Brown Speckled Floor Tile 2nd Floor Classroom 92 14A, 14B Good Non-Friable NAD
Old Administration
Building
Beige Mastic Associated with HA-
2nd Floor Classroom 92 15A, 15B Good Non-Friable NAD
Old Administration
Building Gray Plaster Wall Base Coat 1st Floor Classroom 16A, 16B, 16C Good Non-Friable NAD
Old Administration
Building
White Joint Compound
Associated with Gypsum Board 2nd Floor Copier Room 17A, 17B Good Friable NAD
18 Townline Building Gray Concrete Block Mortar Throughout 18A, 18B Good Non-Friable NAD
19 Laurel Building Gray Concrete Block Mortar Throughout 19A, 19B Good Non-Friable NAD
20 HSU Building Beige Fiber Reinforced Plastic
Panel Mastic 1st Floor Shower, Restrooms 20A, 20B Good Non-Friable NAD
21 HSU Building 9" Light and Dark Brown
Patterned Floor Tile 1st FloorThroughout 21A, 21B Good Non-Friable 3% Chrysotile
22 HSU Building Black Mastic Associated with
HA-21
1st Floor Throughout 22A, 22B Good Non-Friable <1% Chrysotile
Emergency Notification System Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01757
HA No. Building Material Description Material Location Sample Number Condition Friability Asbestos
Content Notes
23 HSU Building 9" Tan and Brown Floor Tile 2nd Floor Hallway 23A, 23B Good Non-Friable 3% Chrysotile
24 HSU Building Black Mastic Associated with HA-
2nd Floor Hallway 24A, 24B Good Non-Friable NAD
25 HSU Building Gray Concrete Block Mortar 1st Floor Hallway 25A, 25B Good Non-Friable NAD
26 Smith Building 12" Orange and White Patterned
Floor Tile 1st and 2nd Floor Hallways 26A, 26B Good Non-Friable NAD
27 Smith Building Black Mastic Associated with HA-
1st and 2nd Floor Hallways 27A, 27B Good Non-Friable NAD
28 Smith Building 1' x 1' Ceiling Tile 1st Floor Office 28A, 28B Good Friable NAD
29 Smith Building 2' x 2' Fissured Ceiling Tile 2nd Floor Gallery 29A, 29B Good Friable NAD
30 Smith Building Gypsum Ceiling 1st Floor Visitation 30A, 30B Good Friable NAD
NAD = No Asbestos Detected
Notes:
Table 2
RCRA-8 Metals in Paint Summary
Emergency Notification System Project
MCI Framingham
99 Loring Drive
Framingham, Massachusetts 01701
Sample ID Building Sample Description Sample Location Arsenic Barium Cadmium Chromium Lead Selenium Silver Units
RCRA-1
Old Administration
Building
White/Beige/Blue Paint on Brick Wall
3rd Floor Hallway, Industries 12 830 51 58 13000 <4.0 1.7 mg/Kg
RCRA-2
Old Administration
Building
White Paint on Gypsum
Board Wall 3rd Floor Industries <4.0 52 <0.80 2.3 23 <8.0 <0.80 mg/Kg
RCRA-3
Old Administration
Building
White Paint on Gypsum
Board Wall 2nd Floor Classroom <2.0 20 <0.40 4.1 20 <4.0 <0.40 mg/Kg
RCRA-4
Old Administration
Building
Gray Paint on Brick
Wall 2nd Floor Pool Room <2.0 510 <0.40 530 72000 <4.0 1.1 mg/Kg
RCRA-5 Townline Building White Paint on Metal
Ceiling
1st Floor Common
Area <4.0 <20 <0.81 2.2 7.8 <8.1 <0.81 mg/Kg
RCRA-6 Laurel Building Blue/White Paint on
Concrete Wall
1st Floor Common
Area <2.0 1100 0.45 2.3 24 <4.0 <0.40 mg/Kg
RCRA-7 Smith Building Gray/White Paint on
Plaster Wall 1st Floor Hallway <2.0 220 <0.40 5.6 4.0 <4.0 <0.40 mg/Kg
RCRA-8
Old Administration
Building
Gray/White Paint on
Plaster Wall Chapel <2.0 560 0.50 8.1 6800 <4.0 <0.40 mg/Kg
Acronyms and Abbreviations:
mg/Kg = milligram per kilogram
FIGURES
ATTACHMENT A
Asbestos Accreditations
Inspector Certifications
Inspector Brandon Wabble
Certification Asbestos Inspector
Certified By The Commonwealth of Massachusetts Department of Labor Standards
Certification Number AI000377
Expiration Date July 26, 2025
ATTACHMENT B
Laboratory Analytical Report – Asbestos
EMSL Analytical, Inc.
6340 CastlePlace Dr. Indianapolis, IN 46250
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501105EMSL Order:
Customer ID: ACAD78AJ
Customer PO: 30263340
Project ID:
Attention: Phone:Greg Donovan (617) 778-8212
Fax:ARCADIS U.S., Inc.
Received Date:126 N Jefferson Street 01/24/2025 9:51 AM
Analysis Date:Suite 400 01/24/2025 - 01/25/2025
Collected Date:Milwaukee, WI 53202
Project: 30263340
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1A
162501105-0001
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray Brick Mortar
HA: 1
1B
162501105-0002
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray Brick Mortar
HA: 1
2A
162501105-0003
None DetectedGypsum
Non-fibrous (Other)
90%
8%
Cellulose
Glass
2%
<1%
White
Non-Fibrous
Homogeneous
Gypsum Board
HA: 2
2B
162501105-0004
None DetectedGypsum
Non-fibrous (Other)
90%
8%
Cellulose
Glass
2%
<1%
White
Non-Fibrous
Homogeneous
Gypsum Board
HA: 2
3A
162501105-0005
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
12' White w/ Black
Streak Floor Tile
HA: 3
3B
162501105-0006
None DetectedNon-fibrous (Other)100%Gray/White
Non-Fibrous
Homogeneous
12' White w/ Black
Streak Floor Tile
HA: 3
4A
162501105-0007
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige Mastic
Associated w/ HA-3
HA: 4
4B
162501105-0008
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige Mastic
Associated w/ HA-3
HA: 4
5A
162501105-0009
None DetectedQuartz
Non-fibrous (Other)
20%
80%
White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 5
5B
162501105-0010
None DetectedQuartz
Non-fibrous (Other)
20%
80%
White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 5
5C
162501105-0011
None DetectedQuartz
Non-fibrous (Other)
20%
80%
White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 5
6A
162501105-0012
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 6
Initial report from: 01/27/2025 08:11:02
Page 1 of 5ASB_PLM_0008_0002 - 2.31 Printed: 1/27/2025 8:11 AM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501105EMSL Order:
Customer ID: ACAD78AJ
Customer PO: 30263340
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
6B
162501105-0013
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 6
6C
162501105-0014
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 6
7A
162501105-0015
None DetectedGypsum
Non-fibrous (Other)
20%
5%
Cellulose75%Brown/White
Fibrous
Heterogeneous
White Gypsum Board
HA: 7
7B
162501105-0016
None DetectedGypsum
Non-fibrous (Other)
30%
5%
Cellulose65%Brown/White
Fibrous
Heterogeneous
White Gypsum Board
HA: 7
8A
162501105-0017
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
12' Beige Patterned
Floor Tile
HA: 8
8B
162501105-0018
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous
12' Beige Patterned
Floor Tile
HA: 8
9A
162501105-0019
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige Brown Mastic
Associated w/HA-8
HA: 9
9B
162501105-0020
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige Brown Mastic
Associated w/HA-8
HA: 9
10A
162501105-0021
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 10
10B
162501105-0022
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 10
10C
162501105-0023
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White Plaster Wall
Skim Coat
HA: 10
11A
162501105-0024
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 11
11B
162501105-0025
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 11
11C
162501105-0026
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 11
12A
162501105-0027
2% ChrysotileNon-fibrous (Other)98%Beige
Non-Fibrous
Homogeneous
9" Beige w/ Black
Streaks Floor Tile
Page 2 of 5ASB_PLM_0008_0002 - 2.31 Printed: 1/27/2025 8:11 AM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501105EMSL Order:
Customer ID: ACAD78AJ
Customer PO: 30263340
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
HA: 12
12B
162501105-0028
Positive Stop (Not Analyzed)9" Beige w/ Black
Streaks Floor Tile
HA: 12
13A
162501105-0029
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-12
HA: 13
13B
162501105-0030
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-12
HA: 13
14A
162501105-0031
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
12" Brown Sparkled
Floor Tile
HA: 14
14B
162501105-0032
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
12" Brown Sparkled
Floor Tile
HA: 14
15A
162501105-0033
None DetectedQuartz
Non-fibrous (Other)
10%
90%
Tan/Black
Non-Fibrous
Homogeneous
Beige Mastic
Associated w/ HA-14
HA: 15
15B
162501105-0034
None DetectedQuartz
Non-fibrous (Other)
10%
90%
Tan/Black
Non-Fibrous
Homogeneous
Beige Mastic
Associated w/ HA-14
HA: 15
16A
162501105-0035
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray/White
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 16
16B
162501105-0036
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray/White
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 16
16C
162501105-0037
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Hair<1%Gray/White
Non-Fibrous
Homogeneous
Gray Plaster Wall
Base Coat
HA: 16
17A
162501105-0038
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White Joint
Compound
Associated w/
Gypsum Board
HA: 17
17B
162501105-0039
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
White Joint
Compound
Associated w/
Gypsum Board
HA: 17
18A
162501105-0040
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray CMU Mortar
HA: 18
18B
162501105-0041
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray CMU Mortar
HA: 18
Page 3 of 5ASB_PLM_0008_0002 - 2.31 Printed: 1/27/2025 8:11 AM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501105EMSL Order:
Customer ID: ACAD78AJ
Customer PO: 30263340
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
19A
162501105-0042
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray CMU Mortar
HA: 19
19B
162501105-0043
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous
Gray CMU Mortar
HA: 19
20A
162501105-0044
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige FRP Mastic
HA: 20
20B
162501105-0045
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
Beige FRP Mastic
HA: 20
21A
162501105-0046
3% ChrysotileNon-fibrous (Other)97%Brown
Non-Fibrous
Homogeneous
9' Light & Dark Brown
Patterned Floor Tile
HA: 21
21B
162501105-0047
Positive Stop (Not Analyzed)9' Light & Dark Brown
Patterned Floor Tile
HA: 21
22A
162501105-0048
<1% ChrysotileNon-fibrous (Other)100%Gray/Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-21
Result includes a small amount of inseparable attached material
HA: 22
22B
162501105-0049
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-21
HA: 22
23A
162501105-0050
3% ChrysotileNon-fibrous (Other)97%Brown
Non-Fibrous
Homogeneous
9" Tan & Brown
Patterned Floor Tile
HA: 23
23B
162501105-0051
Positive Stop (Not Analyzed)9" Tan & Brown
Patterned Floor Tile
HA: 23
24A
162501105-0052
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-23
HA: 24
24B
162501105-0053
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-23
HA: 24
25A
162501105-0054
None DetectedQuartz
Non-fibrous (Other)
15%
85%
Gray
Non-Fibrous
Homogeneous
Gray CMU Mortar
HA: 25
25B
162501105-0055
None DetectedQuartz
Non-fibrous (Other)
15%
85%
Gray
Fibrous
Homogeneous
Gray CMU Mortar
HA: 25
Page 4 of 5ASB_PLM_0008_0002 - 2.31 Printed: 1/27/2025 8:11 AM
Tel/Fax: (317) 803-2997 / (317) 803-3047 http://www.EMSL.com / indianapolislab@emsl.com
162501105EMSL Order:
Customer ID: ACAD78AJ
Customer PO: 30263340
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
26A
162501105-0056
None DetectedNon-fibrous (Other)100%Pink
Non-Fibrous
Homogeneous
12" Orange & White
Patterned Floor Tile
HA: 26
26B
162501105-0057
None DetectedNon-fibrous (Other)100%Pink
Non-Fibrous
Homogeneous
12" Orange & White
Patterned Floor Tile
HA: 26
27A
162501105-0058
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-26
HA: 27
27B
162501105-0059
None DetectedNon-fibrous (Other)100%Black
Non-Fibrous
Homogeneous
Black Mastic
Associated w/ HA-26
HA: 27
28A
162501105-0060
None DetectedPerlite
Non-fibrous (Other)
15%
5%
Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
1x1 Ceiling Tile
HA: 28
28B
162501105-0061
None DetectedPerlite
Non-fibrous (Other)
15%
5%
Cellulose
Min. Wool
50%
30%
Gray/White
Fibrous
Homogeneous
1x1 Ceiling Tile
HA: 28
29A
162501105-0062
None DetectedPerlite
Non-fibrous (Other)
15%
5%
Cellulose
Min. Wool
60%
20%
Gray/White
Fibrous
Homogeneous
2x2 Fissured Ceiling
Tile
HA: 29
29B
162501105-0063
None DetectedPerlite
Non-fibrous (Other)
15%
5%
Cellulose
Min. Wool
60%
20%
Gray/White
Fibrous
Homogeneous
2x2 Fissured Ceiling
Tile
HA: 29
30A
162501105-0064
None DetectedGypsum
Non-fibrous (Other)
85%
5%
Cellulose
Glass
10%
<1%
Brown/White
Fibrous
Heterogeneous
Gypsum Ceiling
HA: 30
30B
162501105-0065
None DetectedGypsum
Non-fibrous (Other)
35%
5%
Cellulose
Glass
60%
<1%
Brown/White
Fibrous
Heterogeneous
Gypsum Ceiling
HA: 30
Analyst(s)
Paul Rihm (62) Asbestos Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Indianapolis, IN NVLAP Lab Code 200188-0, AZ0939, CA 2575, CO AL-15132, TX 300262, A2LA Accredited - Certificate #2845.25
Page 5 of 5ASB_PLM_0008_0002 - 2.31 Printed: 1/27/2025 8:11 AM
OrderID: 162501105
O r d e r I D
P a g e f d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e d e r I D
P a g e
ATTACHMENT C
Laboratory Analytical Report – RCRA-8 Metals
Project Name:
Customer PO:
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047
IndianapolisLab@emsl.com / www.Emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30265332 TASK NO., 01
Received: 01/24/2025 12:47
01/29/2025 18:01
Christopher Brandt
EMSL Order ID: 162551033
LIMS Reference ID: CD51033
EMSL Customer ID: ACAD78J
MA DOC- FRAMING HIM, MA
Analytical Results
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: RCRA-1/WHITE/BEIGE/BLUE, BRICK, WALL Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-01
1Arsenic M101/29/25 JW 01/29/25 JW12 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5035
1Barium M101/29/25 JW 01/29/25 JW830 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5035
1Cadmium M101/29/25 JW 01/29/25 JW51 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5035
1Chromium M101/29/25 JW 01/29/25 JW58 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5035
25Lead M101/29/25 JW 01/29/25 JW13000 mg/kg 50 mg/kg SW846 3050B SW-846 6010D0.5035
1Selenium M101/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5035
1Silver 01/29/25 JW 01/29/25 JW1.7 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5035
Sample Comments:
Client Sample ID: RCRA-2/WHITE/GYPSUM BOARD, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-02
1Arsenic 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.25
1Barium 01/29/25 JW 01/29/25 JW52 mg/kg 20 mg/kg SW846 3050B SW-846 6010D0.25
1Cadmium 01/29/25 JW 01/29/25 JW<0.80 mg/kg 0.80 mg/kg SW846 3050B SW-846 6010D0.25
1Chromium 01/29/25 JW 01/29/25 JW2.3 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.25
1Lead 01/29/25 JW 01/29/25 JW23 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.25
1Selenium 01/29/25 JW 01/29/25 JW<8.0 mg/kg 8.0 mg/kg SW846 3050B SW-846 6010D0.25
1Silver 01/29/25 JW 01/29/25 JW<0.80 mg/kg 0.80 mg/kg SW846 3050B SW-846 6010D0.25
Sample Comments:
Client Sample ID: RCRA-3/WHITE/GYPSUM BOARD, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-03
1Arsenic 01/29/25 JW 01/29/25 JW<2.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5063
1Barium 01/29/25 JW 01/29/25 JW20 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5063
1Cadmium 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5063
1Chromium 01/29/25 JW 01/29/25 JW4.1 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5063
1Lead 01/29/25 JW 01/29/25 JW20 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5063
1Selenium 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5063
1Silver 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5063
Sample Comments:
Client Sample ID: RCRA-4/GRAY, BRICK, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-04
1Arsenic 01/29/25 JW 01/29/25 JW<2.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5
1Barium 01/29/25 JW 01/29/25 JW510 mg/kg 10 mg/kg SW846 3050B SW-846 6010D0.5
1Cadmium 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5
125Chromium 01/29/25 JW 01/29/25 JW530 mg/kg 120 mg/kg SW846 3050B SW-846 6010D0.5
125Lead 01/29/25 JW 01/29/25 JW72000 mg/kg 250 mg/kg SW846 3050B SW-846 6010D0.5
1Selenium 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5
1Silver 01/29/25 JW 01/29/25 JW1.1 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5
Sample Comments:
[TOC_1]Sample Results[TOC]
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047
IndianapolisLab@emsl.com / www.Emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30265332 TASK NO., 01
Received: 01/24/2025 12:47
01/29/2025 18:01
Christopher Brandt
EMSL Order ID: 162551033
LIMS Reference ID: CD51033
EMSL Customer ID: ACAD78J
MA DOC- FRAMING HIM, MA
Analytical Results
(Continued)
Analyte Results RL Q DF Analysis Date
& AnalystWeight(g) Prep Date
& Tech
Analytical
MethodPrep Method
Client Sample ID: RCRA-5/WHITE, METAL, CEILING, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-05
1Arsenic 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.2472
1Barium 01/29/25 JW 01/29/25 JW<20 mg/kg 20 mg/kg SW846 3050B SW-846 6010D0.2472
1Cadmium 01/29/25 JW 01/29/25 JW<0.81 mg/kg 0.81 mg/kg SW846 3050B SW-846 6010D0.2472
1Chromium 01/29/25 JW 01/29/25 JW2.2 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.2472
1Lead 01/29/25 JW 01/29/25 JW7.8 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.2472
1Selenium 01/29/25 JW 01/29/25 JW<8.1 mg/kg 8.1 mg/kg SW846 3050B SW-846 6010D0.2472
1Silver 01/29/25 JW 01/29/25 JW<0.81 mg/kg 0.81 mg/kg SW846 3050B SW-846 6010D0.2472
Sample Comments:
Client Sample ID: RCRA-6/BLUE/WHITE, CONCRETE, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-06
1Arsenic 01/29/25 JW 01/29/25 JW<2.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5038
1Barium 01/29/25 JW 01/29/25 JW1100 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5038
1Cadmium 01/29/25 JW 01/29/25 JW0.45 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5038
1Chromium 01/29/25 JW 01/29/25 JW2.3 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5038
1Lead 01/29/25 JW 01/29/25 JW24 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5038
1Selenium 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5038
1Silver 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5038
Sample Comments:
Client Sample ID: RCRA-7/GRAY/WHITE, PLASTER, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-07
1Arsenic 01/29/25 JW 01/29/25 JW<2.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5032
1Barium 01/29/25 JW 01/29/25 JW220 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5032
1Cadmium 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5032
1Chromium 01/29/25 JW 01/29/25 JW5.6 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5032
1Lead 01/29/25 JW 01/29/25 JW4.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5032
1Selenium 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5032
1Silver 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5032
Sample Comments:
Client Sample ID: RCRA-8/GRAY/WHITE, PLASTER, WALL, INTACT Date Sampled: 01/23/25
Matrix: Solid LIMS Reference ID: CD51033-08
1Arsenic 01/29/25 JW 01/29/25 JW<2.0 mg/kg 2.0 mg/kg SW846 3050B SW-846 6010D0.5041
1Barium 01/29/25 JW 01/29/25 JW560 mg/kg 9.9 mg/kg SW846 3050B SW-846 6010D0.5041
1Cadmium 01/29/25 JW 01/29/25 JW0.50 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5041
1Chromium 01/29/25 JW 01/29/25 JW8.1 mg/kg 0.99 mg/kg SW846 3050B SW-846 6010D0.5041
10Lead 01/29/25 JW 01/29/25 JW6800 mg/kg 20 mg/kg SW846 3050B SW-846 6010D0.5041
1Selenium 01/29/25 JW 01/29/25 JW<4.0 mg/kg 4.0 mg/kg SW846 3050B SW-846 6010D0.5041
1Silver 01/29/25 JW 01/29/25 JW<0.40 mg/kg 0.40 mg/kg SW846 3050B SW-846 6010D0.5041
Sample Comments:
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047
IndianapolisLab@emsl.com / www.Emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30265332 TASK NO., 01
Received: 01/24/2025 12:47
01/29/2025 18:01
Christopher Brandt
EMSL Order ID: 162551033
LIMS Reference ID: CD51033
EMSL Customer ID: ACAD78J
MA DOC- FRAMING HIM, MA
CertificationsAnalyte
Certified Analyses included in this Report
SW-846 6010D in Solid
16-A2LA ChemistryArsenic
16-A2LA ChemistryBarium
16-A2LA ChemistryCadmium
16-A2LA ChemistryChromium
16-A2LA ChemistryLead
16-A2LA ChemistrySelenium
16-A2LA ChemistrySilver
[TOC_1]Certified
Analyses[TOC]
List of Certifications
Code Description Number Expires
16-MO 10180Missouri Drinking Water 03/31/2026
16-NYDOH 12130New York Potable Water, Metals Solid and Hazardous Waste - Asbestos 04/01/2025
16-AIHA ELLAP 157245EMSL Analytical, Inc. Indianapolis, IN AIHA-LAP, LLC ELLAP Accredited 06/01/2025
16-AIHA IHLAP 157245EMSL Analytical, Inc. Indianapolis, IN AIHA-LAP, LLC IHLAP Accredited 06/01/2025
16-CA ELAP 2575California Metals in DW, Chemistry and Bulk Asbestos in Hazardous Waste 06/30/2025
16-A2LA Food 2845.11A2LA Food Microbiology 01/31/2026
16-A2LA Chemistry 2845.25A2LA Environmental and Chemistry 01/31/2026
16-IN Metals/Asbestos C-49-09Indiana Lead and Metals and Asbestos in Drinking Water 12/31/2026
16-OHDOH E10040Ohio - Lead in Paint Chips, Wipes, Soil and Air 05/03/2025
16-FLDOH E871170Florida Asbestos and Metals in Drinking Water, PCBs 06/30/2025
16-NJDEP IN002New Jersey Metals, Organics and Inorganics in DW PCBs 06/30/2025
16-IN Colilert/HPC M-49-06Indiana Colilert and HPC 12/31/2026
Please see the specific Field of Testing (FOT) on www.emsl.com <http://www.emsl.com> for a complete listing of parameters for which EMSL is certified.
[TOC_1]Certifications[TOC]
Notes and Definitions
Item Definition
M1 The spike recovery for this QC sample is outside of established control limits possibly due to sample matrix interference.
Laboratory Control Samples(LCS/LCSD) recovery were acceptable.
(Dig) For metals analysis, sample was digested.
[2C] Reported from the second channel in dual column analysis.
DF Dilution Factor
MDL Method Detection Limit.
ND Analyte was NOT DETECTED at or above the detection limit.
NR Spike/Surrogate showed no recovery.
Q Qualifier
RL Reporting Limit
Wet Sample is not dry weight corrected.
[TOC_1]Qualifiers, Definitions and Disclaimer[TOC]
EMSL Sales Rep:
Reported:
ARCADIS U.S., Inc. [ACAD78J]
25 Braintree Hill Office Park, Suite 200
Braintree, MA 02184
EMSL Analytical, Inc.
6340 Castleplace Drive, Indianapolis, IN, 46250
Telephone: 317.803.2997 Fax:317.803.3047
IndianapolisLab@emsl.com / www.Emsl.com
Greg DonovanAttention:
(617) 778-8212 greg.donovan@arcadis.com
30265332 TASK NO., 01
Received: 01/24/2025 12:47
01/29/2025 18:01
Christopher Brandt
EMSL Order ID: 162551033
LIMS Reference ID: CD51033
EMSL Customer ID: ACAD78J
MA DOC- FRAMING HIM, MA
Measurement of uncertainty and any applicable definitions of method modifications are available upon request. Per EPA NLLAP policy, sample results are not blank corrected.
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. QC sample results are within quality control criteria and met method specifications unless otherwise noted. All results for soil samples are reported on a dry weight basis, unless otherwise noted.
Aleks Kuchenbrod Laboratory Manager or other approved signatory
PROJECT NO. DRM 2024-57 #8
M.C.I. FRAMINGHAM – EMERGENCY NOTIFICATION SYSTEM
FRAMINGHAM, MA
RCRA-8 METAL CONTAINING PAINT HANDLING January 30, 2025
028000 - 1 of 13
SECTION 028000
RCRA-8 METAL CONTAINING PAINT HANDLING
PART 1 - GENERAL
1.1 GENERAL PROVISIONS
A. Attention is directed to the CONTRACT and GENERAL CONDITIONS and all Sections within Division 01 – GENERAL REQUIREMENTS, which are hereby made a part of this Section of the Specifications.
1.2 DEFINITIONS
A. The following definitions shall be applicable to this Section:
“Site”: Refers to the various buildings located at the Massachusetts Correctional Institution (MCI) Framingham located at 99 Loring Drive in Framingham, Massachusetts 0702 as described by the Contract Documents and Drawings.
“Owner": Refers to the Massachusetts Department of Correction (DOC) and their designated, authorized personnel.
“Consultant”: Refers to Arcadis U.S., Inc. and their designated, authorized personnel.
“Contractor”: Refers to the General Contractor and all Subcontractors who are performing remediation, renovation, demolition, construction and site restoration work outlined by the Contract Documents. Contractor as referenced, applies to ALL trades (including Filed Subcontractors) working at the site.
1.3 DESCRIPTION OF WORK
A. The Contractor shall be made aware that lead and other RCRA-8 metals are confirmed or assumed to be present within painted components throughout the Site which will be impacted by the Emergency Notification System Project. All work under this Section shall be performed to minimize the quantity of hazardous waste generated, protect the health and safety of all site personnel and building occupants, the welfare of the public, and avoid adverse environmental impacts.
B. The Contractor shall be required to comply with all aspects of the Occupational Safety and Health Administration (OSHA) Regulations pertaining to lead and other RCRA-8 metals with regards to disturbance of these materials when performing their work.
C. It shall be the sole responsibility of the Contractor for compliance with this Section, including all costs associated with, but not limited to:
028000 - 2 of 13
• Compliance with OSHA 29 CFR 1926.62 Lead Regulations.
• Compliance with OSHA 29 CFR 1926.1118 Arsenic Regulations
• Compliance with OSHA 29 CFR 1926.1126 Chromium Regulations.
• Compliance with OSHA 29 CFR 1926.1127 Cadmium Regulations.
• Compliance with OSHA 29 CFR 1926.1126 Chromium Regulations.
• USEPA’s Renovation, Repair and Painting Final Rule (RRP) (40 CFR 745)
• RCRA Regulations Title 40 CFR Parts 239 - 282
• Development and implementation of a Compliance Program.
• Development and implementation of a Respiratory Program.
• Development and implementation of a Medical Monitoring Program.
• Development and implementation of a Hazard Communication Program.
• Performance of any Negative Exposure Assessments required.
• Providing all medical examinations required.
• Providing all equipment required (Including appropriate PPE)
• Providing all engineering controls and associated work practices.
• Disposing of all materials in accordance with local, state and federal regulations.
D. Due to the age of the buildings, previous painting history, and the results of Arcadis’
RCRA-8 Paint Testing Report dated January 30, 2025, the Contractor shall assume that all painted surfaces contain lead and other RCRA-8 metals. The Contractor must comply with this Section as well as all local, state and federal regulations governing the removal, transport, and disposal of RCRA-8 metals in paint.
E. In the absence of analytical testing results, Contractor shall assume that paints and coatings impacted by the Emergency Notification System project contain RCRA-8 metals. The abatement, removal, handling, containerization, and disposal/recycling of wastes shall be in accordance with this Section.
F. It should be noted that the abatement of RCRA-8 metal containing paint by a licensed
Lead Abatement Contractor shall not be required for performance of the abatement and demolition work outlined under this Contract. The building is not considered a residence where children under the age of six (6) reside, therefore, abatement of lead-containing components will not be required as per Massachusetts Department of Public Health (DPH) "Child Lead Poisoning and Prevention Regulations. However, compliance with the OSHA Lead in Construction Standard is required under this Contract.
G. OSHA regulates activities that disturb the lead and other RCRA-8 metals by the use of manual techniques. Regulated activities include but are not limited to abrasive blasting, welding, drilling, cutting, burning on structures, manual scraping or sanding, and manual demolition of components. The work practices described in this Section are intended to adequately protect the workers from exposure to lead, and other RCRA-8 metals, provide a safe workplace, and protect the environment. It shall be the Contractors responsibility to comply with this Section as well as any other provisions/requirements outlined by OSHA and other applicable regulations.
H. Materials and Equipment: The work of this Section, without limiting the generality thereof, includes the furnishing of labor, materials, tools, equipment, services and
028000 - 3 of 13 incidentals necessary to safely accomplish tasks which will disturb lead and other RCRA-8 metals.
I. Approvals and Inspections: Temporary facilities, work procedures, equipment, materials, services, and agreements must fully comply with EPA, OSHA, RCRA, and NIOSH recommendations, standards and guidelines, as well as any other applicable federal, state, and local regulations. Where there exists an overlap of these regulations and guidelines, the most stringent shall apply.
J. Toxicity Characteristic Leaching Procedure Testing: All materials which are determined to be hazardous waste or regulated waste for lead and other RCRA-8 metals shall be disposed of by the Contractor as specified herein. On behalf of the Owner the Consultant shall perform representative Toxicity Characteristic Leaching Procedure (TCLP) tests of painted waste debris to ensure the material is properly profiled for disposal. This shall also include all testing required by the disposal or recycling facility. The Contractor shall provide 48 hours’ notice to the Owner and Consultant, once waste has been packaged for transport and disposal, that abatement waste is ready to be tested. No additional waste will be permitted to enter that waste stream following collection of TCLP samples. All costs associated with TCLP testing to profile the waste material shall be borne by the Owner. If the material is found to be hazardous waste or regulated waste, the Contractor shall provide appropriate drums/containers for use. The Contractor shall properly handle and transport all hazardous waste or regulated waste material into the drums/containers provided.
K. Disposal: The Contractor shall dispose of painted debris and associated materials in accordance with Part 3.6 of this Section. All costs associated with proper disposal of the waste materials (whether hazardous or regulated) shall be borne by the Owner.
The costs for non-hazardous materials shall be included under the Base Bid. All materials, whether hazardous, non-hazardous or regulated shall be disposed of in accordance with all laws, this contract, and any or all other applicable federal, state county or local regulations and guidelines. It shall be the sole responsibility of the Contractor to assure compliance with all laws and regulations relating to waste disposal.
1.4 SITE WORK DEFINITIONS
A. Action Level: Action Level as defined by OSHA shall refer to employee exposure, without regard to the use of respirators, to an airborne concentration of lead, and other RCRA-8 metals calculated as an eight (8)-hour time-weighted average (TWA).
B. Competent Person: Competent Person shall refer to a person who is capable of identifying existing and predictable hazards in the surroundings or working conditions and who has authorization to take prompt corrective measures to eliminate them.
C. HEPA Filter: HEPA Filter shall refer to a filter capable of filtering out monodispersive particles of 0.3 microns or greater diameter from a body of air at 99.97 percent efficiency or greater.
028000 - 4 of 13
D. Lead and RCRA-8 Metals Paint: Shall refer to paint found or assumed to contain lead and other RCRA-8 metals in any concentration as indicated in this Section.
E. Permissible Exposure Limit (PEL): PEL shall refer to employee exposure, without regard to the use of respirators, to an airborne concentration of lead and other RCRA- 8 metals calculated as an eight (8) hour time-weighted average.
1.5 PERMITS AND INSPECTIONS
A. Notifications/Approvals: The Contractor shall make, in proper and timely fashion, any necessary notifications to relevant local, state, and federal authorities and shall obtain and comply with the provisions of all permits or applications required by the work specified, as well as make all required submittals required under those auspices.
This is the start of the file's text. The full file is on GovTribe.