Drawings_RolstonCabinRebid_16157.pdf
PDF 18 MB Posted
- Solicitation number
- RFQ-171-250000000573-2
- Issued by
- Oakland County, Michigan
About this file
This is a comprehensive architectural renovation set of documents for the Rolston Cabin at the Holly Recreation Area in Holly, Michigan, prepared by WTA Architects and MacMillan Associates for the Michigan Department of Technology, Management and Budget (DTMB) State Facilities Administration. The project involves detailed renovation and restoration of a historic log cabin, with plans covering structural, electrical, and architectural aspects. The renovation is planned in multiple phases, with key dates including 50% owner review on 06-06-24, 90% owner review on 12-11-24, initial bid issuance on 01-17-25, and potential re-bid on 07-18-25. The project involves extensive log restoration, including replacing deteriorated logs, re-leveling floor joists, repairing structural elements, and updating electrical systems.
The documents provide intricate details for a comprehensive restoration, including specific instructions for log replacement, structural reinforcement, and electrical system upgrades. The electrical plans call for surface-mounted conduits painted to match log colors, tamper-resistant receptacles, and updated lighting fixtures. The project appears to be funded through the state's Department of Natural Resources (DNR), with a focus on preserving the historical integrity of the cabin while bringing it up to modern safety and functional standards. The renovation will include replacing damaged structural components, updating electrical infrastructure, and maintaining the cabin's original architectural character, with careful attention to matching original log sizes, dimensions, and construction techniques.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Th e
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7
F:
(8
) 3
-7 w w w
.ro w ep sc
.c om
CI
VI
L
LE
G
EN
D
C100
Th e
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7
F:
(8
) 3
-7 w w w
.ro w ep sc
.c om
CI
VI
L
NO
TE
S
DE
TA
IL
S
C101
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7
F:
(8
) 3
-7 w w w
.ro w ep sc
.c om
R
PR
SE
CO
OW
E
OF
ES
SIO
NA
L
RV
ICE
S
MP
AN
Y
EX
IS
TI
NG
C O
ND
IT
IO
NS
C
IV
IL
D
EM
O
LI
TI
O
N
PL
AN
C200
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7
F:
(8
) 3
-7 w w w
.ro w ep sc
.c om
R
PR
SE
CO
OW
E
OF
ES
SIO
NA
L
RV
ICE
S
MP
AN
Y
CI
VI
L
SI
TE
P
LA
N
C300
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7 w w w
.ro w ep sc
.c om
R
PR
SE
CO
OW
E
OF
ES
SIO
NA
L
RV
ICE
S
MP
AN
Y
CI
VI
L G
RA
DI
NG
P
LA
N
C400
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7 w w w
.ro w ep sc
.c om
R
PR
SE
CO
OW
E
OF
ES
SIO
NA
L
RV
ICE
S
MP
AN
Y
SO
IL
E
RO
SI
O
N
KE
Y
C500
R ow e Bu ild in g
S.
S ag in aw
S t., S ui te
Fl in t, M I 4
O
0)
-7 w w w
.ro w ep sc
.c om
R
PR
SE
CO
OW
E
OF
ES
SIO
NA
L
RV
ICE
S
MP
AN
Y
SO
IL
M
AP
C501
SHEET NUMBERPROJECT NUMBER
PROJECT DATE
CHECKED BY
SHEET TITLE
COPYRIGHT 2024C
Saginaw, Michigan 48607 989 752 8107
100 S Jefferson Ave, Suite 601
WTAARCH.COM
ARCHITE SCT
(989) 894-4300 F (989) 894-9930 www.macmillanassociates.com
714 EAST MIDLAND STREET BAY CITY, MICHIGAN 48706
MacMILLAN ASSOCIATES
CONSULTING ENGINEERS
2/ 3/
1:
A
M R
AI
N
EY
M
C C
AR
TH
Y (R
M C
C
AR
TH
Y@
M
AC
M
IL
LA
N
AS
SO
C
IA
TE
S.
C O
M
F:
\1
5- W
TA
\2
0-
R O
LS
TO
N C
AB
IN
R
EN
O
VA
TI
O
N S\
-1
S1
.0
PL
AN
PROJECT TITLE
DATENO. REVISION
ROLSTON CABIN
HOLLY RECREATION AREA
HOLLY MICHIGAN
2016062
51023
INDEX NO.
751/16157.BDW
FILE NO.
P L U R I B U E
S U N U M
C I R C U M S P I C E
S I QU EREI S PENI NSUL AM A MOE NA M
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ADAM P. LACH, RA, DIRECTOR
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
RENOVATIONS TO:
06-06-2450% OWNER REVIEW
10-08-24PHASE 500, 50% OWNER REVIEW
12-11-24PHASE 500, 90% OWNER REVIEW
01-17-25ISSUED FOR BIDS
07-18-25ISSUED FOR RE-BIDS
CABIN AND WOOD SHED
FRAMING PLAN, NOTES AND
DETAILS
BEM
S1.01SHED FRAMING PLAN
1/4"=1'-0"
NORTH
S1.01
LEGEND
WP1 - WOOD POST - 4x4 PRESSURE TREATED
WP2 - WOOD POST - 6x6 PRESSURE TREATED
F1- FOOTING- 12" DIAMETER X 6" THICK CONCRETE
F2- FOOTING- 16" DIAMETER X 6" THICK CONCRETE
EXISTING WOOD RAFTERS AT 2'-0" O.C.
WP2
WP2
WP2
S2.01
S2.02
S2.02
S2.01
(2)2x8 - 2 SPAN
(2)2x12
2x12
2x12 AT 1'-4" O.C.
WP1
WP1
(2)2x12
(2 )2 x1
(2 )2 x1
WP1
W P1
(2)2x12 2-SPAN
W P1
W P1
CABIN/PORCH PLAN
1/4"=1'-0"
NORTH
SHED SECTION
1/2"=1'-0"
GRADE
REMOVE AND
REPLACE EXISTING
CMU WALL TO INSTALL
NEW POST 3'
-6 " M
IN
CONCRETE FOOTING,
SEE PLAN
EX CONCRETE SLAB
POST, SEE PLAN
PRESSURE TREATED
2X8 SILL PLATE
2X4 GIRT AT 4'-0" OC MAX
WITH (4)#16d NAILS
NEW VERTICAL LOG
SIDING, SEE ARCH
DRAWINGS
EX RAFTER
EX ROOF
EX RAFTER
WOOD BEAM,
SEE PLAN
(6) 5/16"x4" GRK SCREWS EACH SIDE
OF POST (12 TOTAL) AT MIDDLE POST
(3) 5/16"x4" GRK SCREWS EACH SIDE
OF POST (6 TOTAL) AT END POSTS
S1.01
F2
F2
F2
F1
F1
F1
F1
W P1
F1
F1 F1
W P1
F1
GENERAL
1. VERIFY DIMENSIONS BEFORE COMMENCING WORK. REPORT DISCREPANCIES TO
THE ARCHITECT.
2. ALL WORK SHALL CONFORM TO MICHIGAN BUILDING CODE 2015.
3. DESIGN LOADS
a. DESIGNED IN ACCORDANCE WITH MICHIGAN BUILDING CODE 2015.
b . ROOF SNOW LOAD:
GROUND SNOW LOAD PG = 25 PSF
FLAT ROOF SNOW LOAD, PF = 21 PSF
SNOW EXPOSURE FACTOR, CE = 1.0
SNOW LOAD IMPORTANCE FACTOR, I = 1.0
THERMAL FACTOR, CT = 1.2
c. PORCH FLOOR LIVE LOAD: 60 PSF
d. WIND LOADS:
BASIC WIND SPEED VULT = 115 MPH
VASD = 90 MPH
WIND EXPOSURE B
INTERNAL PRESSURE COEFFICIENT, GC PI = +/- 0.18
FOUNDATION NOTES
1. FOUNDATIONS ARE DESIGNED BASED ON SOIL BEARING OF 2000 PSF. IF SOIL OF
THIS CAPACITY IS NOT FOUND AT THE ELEVATION NOTED, ENLARGE OR LOWER
FOOTINGS AT THE DIRECTION OF THE ARCHITECT/ENGINEER.
2. CENTER FOOTINGS UNDER COLUMNS UNLESS NOTED.
CONCRETE NOTES
1. ACI BUILDING CODE (318); MANUAL OF STANDARD PRACTICE FOR DETAILING (315)
FOR THE MIXING, FABRICATION AND PLACEMENT OF CONCRETE, REINFORCING
STEEL, AND ACCESSORIES.
2. CONCRETE STRENGTH - (STANDARD) WEIGHT CONCRETE:
FOOTINGS: F'C = 3000 MINIMUM PSI
3. REINFORCING - BARS: ASTM A-615 GRADE 60
WELDED WIRE FABRIC: ASTM A-1064
4. WATER/CEMENT RATIO LIMITS:
F'C = 3000 PSI 0.68 NON-AIR ENTRAINED, 0.50 AIR ENTRAINED
5. SLUMP LIMITS:
3” FOR FOUNDATIONS
WOOD FRAMING
1. DIMENSIONAL FRAMING MATERIAL SHALL BEAR THE GRADE MARK OF AN ALSC
APPROVED AGENCY, KILN DRIED, AND HAVE THE FOLLOWING MINIMUM STRESS
GRADE:
2x4 SHED WALL GIRTS: SPRUCE-PINE-FIR, CONSTRUCTION GRADE OR BETTER.
2x4 AND LARGER: SOUTHERN PINE #2 PRESSURE TREATED.
REPLACEMENT LOGS: RED PINE
2. WOOD TO BE IN CONTACT WITH CONCRETE, MASONRY, OR GRADE SHALL BE
PRESSURE TREATED.
RIDGE
S2.02
JOIST CONNECTION
1 1/2"=1'-0"
WOOD JOIST, SEE PLAN
WOOD DECKING, SEE ARCH
SIMPSON STRONG TIE
LUS28 FACE MOUNT HANGER
WOOD BEAM,
SEE PLAN
NOTE RAILING IS NOT SHOWN,
SEE ARCH. DRAWINGS
S1.01
5'-0 3/4"
EX FLOOR JOIST
SPAN, SEE NOTE 1
EX FLOOR JOIST
SPAN
W P1
F1
WOOD STEPS, SEE
ARCH DRAWINGS
WOOD STAIR
STRINGERS
NOTE:
1. DOORS ARE CURRENTLY NOT ABLE TO SWING OPEN FULLY DUE TO
SLOPED FLOOR JOIST DUE TO DETERIORATED BEARING LOGS. THE
FLOOR JOIST WILL NEED TO BE JACK UP AND RE LEVELED BEFORE
REPLACEMENT LOGS ARE INSTALLED.
CHECKED BY
SHEET TITLE
COPYRIGHT 2024C
Saginaw, Michigan 48607 989 752 8107
100 S Jefferson Ave, Suite 601
WTAARCH.COM
ARCHITE SCT
(989) 894-4300 F (989) 894-9930 www.macmillanassociates.com
714 EAST MIDLAND STREET BAY CITY, MICHIGAN 48706
MacMILLAN ASSOCIATES
CONSULTING ENGINEERS
2/ 3/
1:
A
M R
AI
N
EY
M
C C
AR
TH
Y (R
M C
C
AR
TH
Y@
M
AC
M
IL
LA
N
AS
SO
C
IA
TE
S.
C O
M
F:
\1
5- W
TA
\2
0-
R O
LS
TO
N C
AB
IN
R
EN
O
VA
TI
O
N S\
-1
S2
.0
EL
EV
AT
IO
N S
PROJECT TITLE
DATENO. REVISION
ROLSTON CABIN
HOLLY RECREATION AREA
HOLLY MICHIGAN
2016062
51023
INDEX NO.
751/16157.BDW
FILE NO.
P L U R I B U E
S U N U M
C I R C U M S P I C E
S I QU EREI S PENI NSUL AM A MOE NA M
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ADAM P. LACH, RA, DIRECTOR
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
RENOVATIONS TO:
06-06-2450% OWNER REVIEW
10-08-24PHASE 500, 50% OWNER REVIEW
12-11-24PHASE 500, 90% OWNER REVIEW
01-17-25ISSUED FOR BIDS
07-18-25ISSUED FOR RE-BIDS
ELEVATIONS
BEM
S2.01
WEST ELEVATION
1/2"=1'-0"
NORTH ELEVATION
1/2"=1'-0"
KEYED NOTES
REMOVE AND REPLACE FULL LENGTH LOG
REMOVE AND REPLACE FULL LENGTH LOG,
NOTCH NEW LOG FOR EXISTING ROUND LOG
FLOOR JOIST
EXISTING END BEARING POST TO BE REMOVED
AND REPLACE
HOLES IN END OF LOGS, LOGS ARE STILL SOLID.
FILL HOLES WITH CAULK
REPLACE HALF LOG SKIRTING
ENDS OF LOGS ARE ROTTED AND NEEDS TO BE
REMOVED AND REPLACED
1 1
S2.01
S2.01
EXISTING ACCESS DOOR
DECK FRAMING NOT SHOWN FOR CLARITY,
SEE PLAN S1.01 FOR DECK FRAMING
NOTES
1. SHORE EXISTING WALL AND FLOOR FRAMING AS REQUIRE TO REPLACE
LOGS.
2. RE LEVEL FLOOR JOIST BEFORE ADDING REPLACEMENT LOG ON NORTH
AND SOUTH SIDE.
3. ALL NEW MEMBERS SHALL MATCH THE SIZE AND DIAMETER OF THE
EXISTING MEMBERS.
4. SEE ARCHITECT SHEET A5.01 FOR ADDITIONAL LOG RESTORATION
NOTES.
CHECKED BY
SHEET TITLE
COPYRIGHT 2024C
Saginaw, Michigan 48607 989 752 8107
100 S Jefferson Ave, Suite 601
WTAARCH.COM
ARCHITE SCT
(989) 894-4300 F (989) 894-9930 www.macmillanassociates.com
714 EAST MIDLAND STREET BAY CITY, MICHIGAN 48706
MacMILLAN ASSOCIATES
CONSULTING ENGINEERS
2/ 3/
1:
A
M R
AI
N
EY
M
C C
AR
TH
Y (R
M C
C
AR
TH
Y@
M
AC
M
IL
LA
N
AS
SO
C
IA
TE
S.
C O
M
F:
\1
5- W
TA
\2
0-
R O
LS
TO
N C
AB
IN
R
EN
O
VA
TI
O
N S\
-1
S2
.0
EL
EV
AT
IO
N S
PROJECT TITLE
DATENO. REVISION
ROLSTON CABIN
HOLLY RECREATION AREA
HOLLY MICHIGAN
2016062
51023
INDEX NO.
751/16157.BDW
FILE NO.
P L U R I B U E
S U N U M
C I R C U M S P I C E
S I QU EREI S PENI NSUL AM A MOE NA M
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ADAM P. LACH, RA, DIRECTOR
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
RENOVATIONS TO:
06-06-2450% OWNER REVIEW
10-08-24PHASE 500, 50% OWNER REVIEW
12-11-24PHASE 500, 90% OWNER REVIEW
01-17-25ISSUED FOR BIDS
07-18-25ISSUED FOR RE-BIDS
ELEVATIONS
BEM
S2.02SOUTH ELEVATION
1/2"=1'-0"
EAST ELEVATION
1/2"=1'-0"
KEYED NOTES
REMOVE AND REPLACE FULL LENGTH LOG
REMOVE AND REPLACE FULL LENGTH LOG,
NOTCH NEW LOG FOR EXISTING ROUND LOG
FLOOR JOIST
EXISTING END BEARING POST TO BE REMOVED
AND REPLACE
HOLES IN END OF LOGS, LOGS ARE STILL SOLID.
FILL HOLES WITH CAULK
REPLACE HALF LOG SKIRTING
ENDS OF LOGS ARE ROTTED AND NEEDS TO BE
REMOVED AND REPLACED
EXISTING FLOOR JOIST
S2.02
S2.02
1 6
NOTES
1. SHORE EXISTING WALL AND FLOOR FRAMING AS REQUIRE TO REPLACE
LOGS.
2. RE LEVEL FLOOR JOIST BEFORE ADDING REPLACEMENT LOG ON NORTH
AND SOUTH SIDE.
3. ALL NEW MEMBERS SHALL MATCH THE SIZE AND DIAMETER OF THE
EXISTING MEMBERS.
4. SEE ARCHITECT SHEET A5.01 FOR ADDITIONAL LOG RESTORATION
NOTES.
CHECKED BY
SHEET TITLE
COPYRIGHT 2024C
Saginaw, Michigan 48607 989 752 8107
100 S Jefferson Ave, Suite 601
WTAARCH.COM
ARCHITE SCT
(989) 894-4300 F (989) 894-9930 www.macmillanassociates.com
714 EAST MIDLAND STREET BAY CITY, MICHIGAN 48706
MacMILLAN ASSOCIATES
CONSULTING ENGINEERS
2/ 3/
1:
A
M R
AI
N
EY
M
C C
AR
TH
Y (R
M C
C
AR
TH
Y@
M
AC
M
IL
LA
N
AS
SO
C
IA
TE
S.
C O
M
F:
\1
5- W
TA
\2
0-
R O
LS
TO
N C
AB
IN
R
EN
O
VA
TI
O
N S\
-1
1- E-
E1 .0
EL
EC
TR
IC
AL
P
LA
N
PROJECT TITLE
DATENO. REVISION
ROLSTON CABIN
HOLLY RECREATION AREA
HOLLY MICHIGAN
2016062
51023
INDEX NO.
751/16157.BDW
FILE NO.
P L U R I B U E
S U N U M
C I R C U M S P I C E
S I QU EREI S PENI NSUL AM A MOE NA M
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
STATE OF MICHIGAN
ADAM P. LACH, RA, DIRECTOR
STATE FACILITIES ADMINISTRATION
DESIGN AND CONSTRUCTION DIVISION
RENOVATIONS TO:
06-06-2450% OWNER REVIEW
10-08-24PHASE 500, 50% OWNER REVIEW
12-11-24PHASE 500, 90% OWNER REVIEW
01-17-25ISSUED FOR BIDS
07-18-25ISSUED FOR RE-BIDS
DEMOLITION AND REVISED
ELECTRICAL FLOOR PLANS
BAV
E1.01
DEMOLITION ELECTRICAL FLOOR PLAN
1/4"=1'-0"
REVISED ELECTRICAL FLOOR PLAN
1/4"=1'-0"
NORTHNORTH
96"
96"
72"
72"
S
S
M EX
EX MASK
EX PANEL
S
SD
SD
S S
M
SD EX
EX MAST
EX PANEL
GENERAL NOTES - REVISED
1. ELECTRICAL CONTRACTOR SHALL INSTALL ALL NEW
CABLING IN SURFACE MOUNTED CONDUIT. CONDUIT SHALL
BE PAINTED TO MATCH THE COLOR OF THE LOGS.
INTERIOR CONDUIT: SHALL BE EMT WITH COMPRESSION
FITTINGS
EXTERIOR CONDUIT: SHALL BE RIGID METAL CONDUIT
2. ALL RECEPTACLE SHALL BE TAMPER RESISTANT. AFCI/GFI
DUAL RATED DEVICES.
3. WIRE ALL EXIT LIGHTS AHEAD OF ANY SWITCHING OFF THE
LOCAL LIGHTING CIRCUIT.
GENERAL NOTES - DEMOLITION
1. ELECTRICAL CONTRACTOR SHALL REMOVE ALL
ROMEX CABLING BACK TO ELECTRICAL PANEL.
2. ALL ITEMS SHOWN DASHED SHALL BE REMOVED.
KEYED NOTES
ELECTRICAL CONTRACTOR SHALL REPLACE
DEVICE INSTALL NEW CONDUIT AND WIRING BACK
TO PANEL. UTILIZE THE CRAWLSPACE TO LIMIT
THE AMOUNT OF VISIBLE CONDUIT.CONDUIT
SHALL BE PAINTED TO MATCH THE COLOR OF THE
LOGS. TYPICAL FOR ALL CIRCUITS.
ELECTRICAL CONTRACTOR SHALL INSTALL NEW
SURFACE MOUNTED CONDUIT TO THE RANGE.
MATCH EXISTING ROMEX CABLE PATH.
ELECTRICAL CONTRACTOR SHALL WALL MOUNT
LIGHT FIXTURE ABOVE THE LOFT AS HIGH AS
POSSIBLE IN LOCATION SHOWN.
ELECTRICAL CONTRACTOR SHALL ROUTE RIGID
METAL CONDUIT DOWN WITHIN THE CRAWLSPACE
AND THEN STUBBED UP AND SURFACE MOUNTED
TO THE SIDE OF THE CABIN.
A 96"
A 96"
A
B
E/EM
B
B
E/EM
A 72"
A
A
A
A
(3)#3
(1)#6 GND
1 1/4"C
R
PA
-2 ,4
S
INV
LIGHT FIXTURE SCHEDULE
TYPE DESCRIPTION
A EXTRA SMALL LANTERN, CLEAR SEEDED GLASS
DIFFUSER, BACK PLATE WALL MOUNT, 75 WALT
MAX A19 BULB, ANTIQUE BRONZE FINISH
VISUAL COMFORT & CO. #OL14300ANBZ
B SMALL LANTERN, CLEAR SEEDED GLASS DIFFUSER,
BACK PLATE WALL MOUNT, 75 WATT MAX A19 BULB,
ANTIQUE BRONZE FINISH, WET LOCATION LISTED
VISUAL COMFORT & CO. #OL14301ANBZ
E/EM LED LAMP HEAD NICKEL-CADMIUM BATTERY EXIT
SIGN, WALL MOUNTED, SINGLE FACE PLATE, TWO
1.5W LEDS, BLACK HOUSING, RED LETTERING, HIGH
OUTPUT, REMOTE CAPABLE
ACUITY #LHQM-LED-B-R-HO
ELECTRICAL SYMBOLS LIST
WALL MOUNTED LIGHT FIXTURE
EXIT LIGHT
SINGLE POLE SWITCH
DIMMER SWITCH
DUPLEX RECEPTACLE
SPECIAL RECEPTACLE
120V SMOKE DETECTOR
METER
ELECTRICAL PANEL
100 WATT UL924 LISTED INVERTER BODINE #ELI-S-250 OR EQUAL
EXISTING
ELECTRICAL CONTRACTOR
DASHED ITEMS DENOTES DEMOLITION
GROUND FAULT INTERRUPTER
SD
S
S
M
INV
EX
EC
GFI
RPA-10
14"
WR
GFI
TYP
GFI
RPA-5
RPA-12
GFI
RPA-7
48"
GFI
RPA-6
48"
GFI
RPA-6
RPA-7
GFI
RPA-5
RPA-8
14"
WR
GFI
RPA-10
RPA-10
100A
NEW EMERGENCY
SERVICE DISCONNECT
RPA-5
EX PANEL
RPA
EX METER
(SHALL
REMAIN)
M
NEW SERVICE
DISC 100 AMP
NEMA 3R
(3)#3
(1)#6 GND
1 1/4" RMC
(4)#3
(1)#6 GND
1 1/4" RMC
#6 GND
6'-0"
3/4"x10'
GND ROD
3/4"x10'
GND ROD
(4)#8
(1)#10 GND
1"C
RANGE
ELECTRICAL RISER DIAGRAM
| A0.00-2016062 |
| A2.01-2016062 |
| A2.02-2016062-cd |
| A5.01-2016062 |
| A5.02-2016062 |
| A5.03-2016062 |
| A6.01-2016062 |
| A7.01-2016062 |
| A7.02-2016062 |
| A7.03-2016062 |
File details come from the government source that posted it. Updated .