This document appears to be related to a Request for Quote (RFQ) for the inspection, testing, repair, and certification of hangar fall protection systems located at 176 WG JBER, Alaska. The solicitation number is W50S6L-24-Q-0013 and it is being issued by the Department of the Army Alaska Army National Guard. The contractor shall provide all management, tools, supplies, equipment, and labor necessary to maintain continuous and safe operations of the hangar fall protection systems. The scope of performance includes, but is not limited to, the inspection, testing, repair, and certification of the hangar fall protection. No additional details about response dates, award dates, pricing terms, set asides, or incumbents are provided in the given information.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F-E Contracting Inc Fall Protection Submittal Elmendorf AFB Hangar 18 December 2009

Design Criteria

All components of the design of the Fall Protection System have been performed in accordance with the requirements of OSHA 1926 Subpart M and ANSI Z359.1

The system has been designed for a maximum of 1 user per horizontal lifeline. The lifeline will be designed base upon the fall of one user. The design of the connections is based upon sequential fall of the 2 users.

Applied load to the existing structure:

Maximum Arresting Force (MAF) = 900 lb Maximum Weight of User (including tools & clothing) = 310 lbs Total Applied Vertical Load 1,210 lbs

Cable Tension Loads (See attached sheets)

Maximum Cable Tension = 3,179 lbs

SUPPLEMENTAL STEEL FRAMING DESIGN

FALL ARREST CABLE PULLEY

© Copyright 2006, DB Industries, Inc.

Instructions for the following series products:

Detachable Roof Anchors

(See back page for specific model numbers.)

User Instruction Manual Tandem Pulley This manual is intended to meet the Manufacturer’s Instructions as required by ANSI-Z359.1 and should be used as part of an employee training program as required by OSHA.

WARNING: This product is part of a personal fall arrest system. The user must follow the manufacturer’s instructions for each component of the system. These instructions must be provided to the user of this equipment. The user must read and understand these instructions before using this equipment. Manufacturer’s instructions must be followed for proper use and maintenance of this equipment. Alterations or misuse of this equipment, or failure to follow instructions, may result in serious injury or death.

IMPORTANT: If you have questions on the use, care, or suitability of this equipment for your application, contact

DBI-SALA.

IMPORTANT: These instructions are designed to assist the user of the DBI-SALA Tandem Pulley when used as a component of a personal fall arrest system. Use of the tandem pulley as a component for personal hauling, traversing or descending is not covered in these instructions and therefore the tandem pulley should not be used for these applications unless additional instructions and training are obtained.

1.0 APPLICATIONS

1.1 PURPOSE: The Tandem Pulley is intended to be used with a horizontal lifeline of 1/2 inch (13 mm) maximum wire rope or synthetic rope that is not sloped more than 5 degrees with an attached personal fall arrest system. This tandem pulley is to be used only as a component of a personal fall arrest system.

Do not hang, lift, or support tools or equipment from the tandem pulley unless additional instructions and training are obtained.

IMPORTANT: The horizontal lifeline that the tandem pulley is attached to shall be designed, installed and used under the supervision of a qualified person (see below for definition) as part of a complete personal fall arrest system that maintains a safety factor of at least two.

Qualified Person: An individual with a recognized degree or professional certificate, and extensive knowledge and experience in the subject field, who is capable of design, analysis, evaluation, and specification in the subject work, project, or product. Refer to OSHA 1910.66, 1926.32, and 1926.502.

A. FALL ARREST: The tandem pulley is used as a component of a personal fall arrest system. Personal fall arrest systems typically include a self retracting lifeline or lanyard, a connector to attach the self retracting lifeline or lanyard to the tandem pulley, and a full body harness. A personal fall arrest system is used where a free fall is possible before the fall is arrested.

1.2 LIMITATIONS: Consider the following applications limitations before using this equipment:

A. LIFELINES: The tandem pulley can only be used on horizontal lifelines of 1/2 inch (13 mm) maximum diameter made from wire rope or synthetic rope.

B. CAPACITY: The tandem pulley is designed for use by persons with a combined weight (clothing, tools, etc.) of no more than 310 lbs. (141 kg) Only one personal fall arrest system may be connected to a single tandem pulley. See the horizontal lifeline instructions for the number of tandem pulleys that can be attached to the horizontal lifeline.

Figure 1 - Tandem Pulley

ID Label

Opening for Carabiner

Frame

C. PERSONAL FALL ARREST SYSTEM: Personal fall arrest systems used with the tandem pulley must meet the system requirements as specified in section 2.5.

D. FREE FALL: Personal fall arrest systems used with the tandem pulley must be rigged to limit the free fall to 6 feet. (1.8 m) See subsystem manufacturer’s instructions for more information.

E. FALL CLEARANCE: There must be sufficient clearance below the user to arrest a fall before the user strikes the ground or other obstruction. The clearance required is dependent on the following factors:

• Elevation of Tandem Pulley • Connecting subsystem length

• Deceleration distance • Movement of the harness attachment element

• Worker’s height • Free fall distance See personal fall arrest system manufacturer’s instructions for more information.

F. TANDEM PULLEY LOAD ANGLE: Loads imposed on the tandem pulley by the personal fall arrest system must remain within thirty degrees of the vertical center line of the horizontal lifeline. See Figure 2.

G. ENVIRONMENTAL HAZARDS: Use of this equipment in hazardous environments may require additional precautions to reduce the possibility of injury to the user or damage to the equipment. Hazards may include, but are not limited to; heat, caustic chemicals, corrosive environments, high voltage power lines, explosive or toxic gases, moving machinery, and sharp edges.

H. TRAINING: This equipment is intended to be installed and used by persons trained in its application and use.

1.3 APPLICABLE STANDARDS: Refer to applicable local, state, and federal (OSHA) requirements governing this equipment for more information on anchorage connectors and associated system components, including OSHA 1910.66 Appendix C and OSHA 1926.502.

2.0 SYSTEM REQUIREMENTS

2.1 COMPATIBILITY OF COMPONENTS: DBI-SALA equipment is designed for use with DBI-SALA approved components and subsystems only. Substitutions or replacements made with non-approved components or subsystems may jeopardize compatibility of equipment and may effect the safety and reliability of the complete system.

2.2 COMPATIBILITY OF CONNECTORS: Connectors are considered to be compatible with connecting elements when they have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to inadvertently open regardless of how they become oriented.

Contact DBI-SALA if you have any questions about compatibility.

Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22.2 kN).

Connectors must be compatible with the anchorage or other system components. Do not use equipment that is not compatible. Non-compatible connectors may unintentionally disengage. See Figure 3.

Connectors must be compatible in size, shape, and strength. Self locking snap hooks and carabiners are required by ANSI Z359.1 and OSHA.

Figure 2 - Pulley Load Angle

30° Maximum Load Angle

30° Maximum Load Angle

2.3 MAKING CONNECTIONS: Only use self-locking snap hooks and carabiners with this equipment. Only use connectors that are suitable to each application. Ensure all connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all connectors are fully closed and locked.

DBI-SALA connectors (snap hooks and carabiners) are designed to be used only as specified in each product’s user’s instructions. See Figure 4 for inappropriate connections. DBI-SALA snap hooks and carabiners should not be connected:

A. To a D-ring to which another connector is attached.

B. In a manner that would result in a load on the gate.

NOTE: Large throat opening snap hooks should not be connected to standard size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates. Large throat snap hooks are designed for use on fixed structural elements such as rebar or cross members that are not shaped in a way that can capture the gate of the hook.

C. In a false engagement, where features that protrude from the snap hook or carabiner catch on the anchor and without visual confirmation seems to be fully engaged to the anchor point.

D. To each other.

E. Directly to webbing or rope lanyard or tie-back (unless the manufacturer’s instructions for both the lanyard and connector specifically allow such a connection).

F. To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and lock, or that roll-out could occur.

Figure 3 - Unintentional Disengagement (Rollout)

Figure 4 - Inappropriate Connections

If the connecting element that a snap hook (shown) or carabiner attaches to is undersized or irregular in shape, a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner. This force may cause the gate (of either a self-locking or a non-locking snap hook) to open, allowing the snap hook or carabiner to disengage from the connecting point.

1. Force is applied to the snap hook.

2. The gate presses against the connecting ring.

3. The gate opens allowing the snap hook to slip off.

Small ring or other non-compatibly shaped element

2.4 ANCHORAGE STRUCTURE STRENGTH: The horizontal lifeline to which the tandem pulley is attached to must be anchored to a structure which supports the required loads for that specific horizontal lifeline system. See the manufacturer’s instructions for horizontal lifelines for the anchorage strength requirements.

From OSHA 1926.500 and 1910.66: Anchorages used for attachment of a personal fall arrest system shall be independent of any anchorage being used to support or suspend platforms, and must support at least 5,000 lbs. (22.2 kN) per user attached; or be designed, installed, and used as part of a complete personal fall arrest system which maintains a safety factor of at least two, and is supervised by a qualified person.

2.5 PERSONAL FALL ARREST SYSTEM: Personal fall arrest systems used with this equipment must meet applicable local, state, and federal (OSHA) requirements. A personal fall arrest system incorporating a full body harness must be capable of arresting a user’s fall with a maximum arresting force of 1,800 lbs.

(8.0 kN), and limit the free fall distance to 6 feet (1.8 m) or less. The deceleration distance must be 42 inches (1.1 m) or less.

3.0 INSTALLATION AND USE

WARNING: Do not alter or intentionally misuse this equipment. Consult DBI-SALA when using this equipment in combination with components or subsystems other than those described in this manual. Some subsystem and component combinations may interfere with the operation of this equipment. Use caution when using this equipment around moving machinery, electrical hazards, chemical hazards, and sharp edges.

WARNING: Consult with your doctor if there is any reason to doubt your fitness to safely absorb the shock from a fall arrest. Age and fitness can seriously affect your ability to withstand falls. Pregnant women and minors must not use this equipment.

3.1 BEFORE EACH USE of this equipment inspect it according to section 5.0.

3.2 PLAN your fall arrest system before installing and using this equipment. Consider all factors affecting your safety during use. The following list gives some important points to consider when planning your system:

A. FALL CLEARANCE: See Figure 5. There must be sufficient clearance in your fall path to prevent striking an object or lower level in the event of a fall. The amount of clearance required is dependent on the application. See personal fall arrest system manufacturer’s instructions for information on calculating fall clearance.

B. SWING FALLS: See Figure 6. Swing falls occur when the anchorage point is not directly overhead. The force of striking an object in a swing fall may cause serious injury or death.

Minimize swing falls by working as directly below the anchorage point as possible. Do not permit a swing fall if injury could occur.

Swing falls will significantly increase the clearance required when a self retracting lifeline or other variable length connecting subsystem is used. If a swing fall situation exists in your application contact DBI-SALA before proceeding.

C. SHARP EDGES: Avoid working where parts of the system will be in contact with, or abrade against, unprotected sharp edges.

D. AFTER A FALL: Components which have been subjected to the forces of arresting a fall must be removed from service and destroyed, or returned to an authorized service center for repair.

E. RESCUE: The employer must have a rescue plan in place when using this equipment. The employer must have the ability to perform a rescue quickly and safely.

3.3 INSTALLATION:

ATTACHING THE TANDEM PULLEY TO THE HORIZONTAL LIFELINE:

Step 1. Insert a carabiner through the anchorage attachment point on the self retracting lifeline (SRL). For connection of a lanyard with a carabiner, go to step 2.

Figure 5 - Fall Clearance

Working Surface

Lower Level or Obstruction

Fall Clearance See Personal Fall Arrest System Requirements

IMPORTANT: Do not connect a snap hook directly to the tandem pulley.

See Figure 7. You must use a self locking carabiner to connect the SRL to the tandem pulley as shown in Figure 8. If a lanyard is used, the lanyard must contain a carabiner captivated to the lanyard for attachment to the tandem pulley.

Step 2. Place the tandem pulley onto the horizontal lifeline from the top down and captivate it on the lifeline by installing the carabiner through the opening at the bottom of the pulley. The carabiner must pass through the opening in both sides of the frame. The pulley wheels should ride on top of the horizontal lifeline. See Figure 8.

3.4 ATTACHING THE PERSONAL FALL ARREST SYSTEM: For general

fall protection use, connect the snap hook from the SRL or lanyard to the D-ring on the back of the full body harness between the shoulders (dorsal D-ring). See personal fall arrest system manufacturer’s instructions for more details on the connection of your PFAS system.

4.0 TRAINING

4.1 It is the responsibility of all users of this equipment to understand these instructions, and to be trained in the correct installation, use, and maintenance of this equipment. These individuals must be aware of the consequences of improper installation or use of this equipment. This user manual is not a substitute for a comprehensive training program. Training must be provided on a periodic basis to ensure proficiency of the users.

WARNING: Training must be conducted without exposing the trainee to a fall hazard. Training should be repeated on a periodic basis.

5.0 INSPECTION

5.1 FREQUENCY:

• Before Each Use: Inspect trolley according to sections 5.2 and 5.3.

• Annually: The trolley must be inspected by a competent person other than the user. See sections 5.2 and 5.3 for inspection guidelines.

5.2 INSPECTION STEPS:

Step 1. Inspect the tandem pulley for damage. Look for cracks or deformities. Look for excessive wear or damage to the anchorage point.

Step 2. Inspect the tandem pulley wheels. All wheels should turn freely and be undamaged.

Step 3. Inspect all subsystems (i.e. carabiner, self retracting lifeline, lanyard, full body harness, and horizontal lifeline) according to the manufacturer’s instructions provided with these components.

Step 4. The warning label must be present and fully legible. See section 8.0.

Step 5. Record inspection results in section 9.0.

WARNING: If this equipment is subjected to the forces of a fall arrest, it must be removed from service and destroyed, or returned to DBI-SALA for inspection and repair.

Figure 6 - Swing Falls

Figure 7 - Incorrect Connection

Figure 8 - Correct Connection

Swing Fall Hazard

Carabiner

Snap Hook

INCORRECT

CORRECT

Carabiner

Tandem Pulley

Lifeline

Carabiner

Side View

5.3 If the inspection reveals an unsafe or defective condition remove the unit from service and destroy or contact DBI-SALA for repair.

6.0 MAINTENANCE, SERVICING, STORAGE

6.1 MAINTENANCE: Clean the tandem pulley using water and mild detergent. Wipe dry with a clean cloth and hang to air dry. Do not force dry with heat. An excessive build-up of dirt, paint, etc. may prevent the tandem pulley from working correctly. Lubrication as needed with a light machine oil.

6.2 SERVICING: Servicing must be completed by an authorized service center. Authorization must be in writing.

6.3 STORAGE: Store this equipment in a cool, dry, clean environment out of direct sunlight. Inspect the tandem pulley after extended storage.

7.0 SPECIFICATIONS

7.1 MATERIALS:

Ball Bearing Rollers: Shielded wheel bearings Lifeline: 1/2 inch (13mm) maximum wire rope or synthetic rope Weight: .6 lbs. (.27 kg) Size: 4.25 in. x 3 in. x 1 in. ( 108.0 mm x 76.2 mm x 25.4 mm)

8.0 LABELING

8.1 These labels must be present and fully legible:

ID Label

Warning Label

ETADNOITCEPSNI SMETINOITCEPSNI

DETON

NOITCAEVITCERROC ECNANETNIAM

DEMROFREP

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

:yBdevorppA

9.0 INSPECTION AND MAINTENANCE LOG

DATE OF MANUFACTURE: _________________________________________________________________

MODEL NUMBER: ________________________________________________________________________

DATE PURCHASED: ______________________________________________________________________

USA Canada 3833 SALA Way 260 Export Boulevard Red Wing, MN 55066-5005 Mississauga, Ontario L5S 1Y9 Toll Free: 800-328-6146 Toll Free: 800-387-7484 Phone: (651) 388-8282 Phone: (905) 795-9333 Fax: (651) 388-5065 Fax: (905) 795-8777 www.capitalsafety.com www.capitalsafety.com

This manual is available for download at www.capitalsafety.com.

A Capital Safety Company

I S O 9 0 0 1

Certificate No. FM 3 9 7 0 9

Form: 5902190 Rev: B

This instruction applies to the following models:

8800023

Additional model numbers may appear on the next printing of these instructions

CARABINER

To visit the Capital Safety website for a different region of the world, Please Select a Region RegisterLogin

Thursday, January 29, 2009

Home

Products

Industry Solutions

Training

Services

Resources

Employment

Press Releases

Contact Us

Business Center

Products » Protecta Products

Self-Locking Carabiner

AJ514A

Easy, one hand operation Rugged, Galvanized forged steel construction 3/4" gate opening Safe, self-locking double-lock mechanism

0.38 lbs. total weight Flexible range of uses Provides a qualified 5,000 lb. anchorage point Meets OSHA 1926 & ANSI Z359 standards

Privacy Statement | Terms Of Use Copyright 2009 Capital Safety Inc.

Page 1 of 1Protecta Fall Protection | Protecta Safety

1/29/2009http://www.capitalsafety.com/Products/ProtectaProducts/tabid/46/ctl/Details/mid/380/ProductId/1596/Def...

SELF RETRACTING LIFELINE

To visit the Capital Safety website for a different region of the world, Please Select a Region Login

Tuesday, September 22, 2009

Home

Products

Industry Solutions

Training

Services

Resources

Employment

Press Releases

Contact Us

Business Center

Products » Protecta Products

Product Instructions

Product Brochures

30' (9m) Steel Cable Self Retracting Lifeline

AD212AG

9 meter (30') working length.

Lightweight device - just under 10 lbs.

Utilizes 3/16" Galvanized cable Zinc coated internal components Shock-Resistant thermoplastic casing Begins fall arrest within 2’ Red end-of-travel indicator Incorporated energy dissipation element Double locking swiveling snaphook on lifeline, carabiner on housing Complies with OSHA 1926 and ANSI Z359.1 (2007) standards Two year warranty, no recertification necessary

Instruction File Description ifu_5902290_protecta_srls.pdf Protecta SRLs Instructions for Use

Brochure Files Description bro_9700017_jrg_revd.pdf Protecta Self Retracting Lifelines Product Brochure

Privacy Statement | Terms Of Use Copyright 2009 Capital Safety Inc.

Page 1 of 1Protecta Fall Protection | Protecta Safety

9/22/2009http://www.capitalsafety.com/Products/ProtectaProducts/tabid/46/ctl/Details/mid/380/Prod...

HORIZONTAL LIFELINE COMPONENTS

• www.capitalsafety.com • France • Tél +33 (o)4 97 10 00 10 • email : information@capitalsafety.com • UK • Tel +44 (o)1928 571 324 • email : info@csgne.co.uk ø 17

19,5 ø 40 ø

19,5

Technical specifi cations

Articulated mono-attachment anchorage Description The EVOLUTION mono-attachment anchorage is the simplest solution for installing lifeline anchorage points. The multi-directional articulation of this anchorage point allows it to become part of any confi guration (wall, fl oor, or overhead) and to cope with every type of solicitation (shearing or tearing away).

Use

• End anchorage for use in every type of installation.

• Multidirectional anchorage articulation allowing its integration at the end of a lifeline whatever the cable axis.

• Recommended for installations on a rigid post or metal structure.

• Attachment (M16 – 5/8”) type defi ned by the nature of the structure.

• Compatible with all the EVOLUTION end brackets.

Materials

• Body: 304L stainless steel

• Hardware: A470 - AISI 304 stainless steel.

Technique

• Breaking strength: 30 kN - 6750 lbf.

• Weight: 0.7 Kg (1.6 lbs)

• Size: 70 x 70 x 64 mm (23/4” x 23/4” x 21/2”)

• Hardware: M16 (5⁄8’’) – AISI 316 type (min. A4 70)

• Torquing: torque load 60 - 80 N/m (45 - 60 lbs/inch)

• Operating temperature range: -40°C to +60°C (-40°F to 140°F)

• Inspection: individual – ISO 9001

• Marking: batch number – month/year of manufacture

• Life duration: >10 years in a normal environment (annual checking recommended)

• Packing individual carton

Options

• Available on request in an AISI 316 stainless steel version for installation in a corrosive environment.

• Other anchorages available:

- Triple articulated attachment (#7240175)

- Mono-attachment anchorage for SALA post (#7240170)

Multi-directional articu-lated anchorage

Attaching axis

M16 mono attachment

Te c h n i c a l f i l e

Page

ART. # 7240176

• www.capitalsafety.com • France • Tél +33 (o)4 97 10 00 10 • email : information@capitalsafety.com • UK • Tel +44 (o)1928 571 324 • email : info@csgne.co.uk

Embout à sertir

Chape d’extrémité

13 15

8, Technical specifi cations

E n d t e n s i o n e r f o r s w a g i n g Description The swaging tensioner is used for creating a safe and defi nitive link between the end of the cable and the lifeline anchorage point. The adjustment function is used for adjusting the cable tension when the need arises.

Use

• Swaged part compatible with all the Sala 8mm cable system.

• Use possible on every type of installation.

• Compatible with all the Sala anchorages.

• Adjustment of tension in the lifeline.

Materials

• Body & clevis 316 stainless steel.

• Swaging: 316 stainless steel.

Description The swaging clevis is used for creating a safe and defi nitive link between the end of the cable and the lifeline anchorage point.

Use

• Swaged end bracket compatible with all the Sala 8mm cable system.

• Use possible on every type of installation.

• Compatible with all the Sala anchorages.

Materials

• Body & clevis 316 stainless steel.

• Swaging: 316 stainless steel.

E n d c l e v i s f o r s w a g i n g

Swaging section

End clevis

Tensioner

Technique

• Breaking strength: 37 kN (8200lbs)

• Weight: 0.8 Kg (1.8 lbs)

• Size: 352 mm - Dia. 22 mm (139/10” - Dia. 9/10”)

• Swaging: min 70mm - compatible with pressure swaging or roller (min. 700 bars)

• Adjustment range: 100 mm (4”)

• Operating temperature range: -40°C to +60°C (-40°F to

140°F)

• Inspection: individual – ISO 9001

• Marking: batch number – month/year of manufacture

• Life duration: >10 years in a normal environment (annual checking recommended))

• Packing: individual

Technique

• Breaking strength: 37 KN (8200lbs)

• Weight: 0.3 Kg (0.7 lbs)

• Size: 166 x 32 - 36mm (61/3” x 11/4” x 14/10” )

• Swaging: min 70mm - compatible with pressure swaging or roller (min. 700 bars)

• Operating temperature range: -40°C to +60°C (-40°F to 140°F)

• Inspection: individual – ISO 9001

• Marking: batch number – month/year of manufacture

• Life duration: >10 years in a normal environment (annual checking recommended)

• Packing individual

Te c h n i c a l f i l e

Page

ART. # 7240165

ART. # 7240160

• www.capitalsafety.com • France • Tél +33 (o)4 97 10 00 10 • email : information@capitalsafety.com • UK • Tel +44 (o)1928 571 324 • email : info@csgne.co.uk

8 mm - 7 x 7 ø m m

8 mm - 7 x 19 ø m m

Technical specifi cations

7 x 1 9 E v o l u t i o n c a b l e s

7 x 7 E v o l u t i o n c a b l e s Description Life line anchorage support designed to allow users to connect and move around in total safety. The link with the end parts is by swaging.

Use

• Compatible with all the Evolution 8mm swaged ends.

• Use possible on every type of installation.

• High breaking strength.

• Average fl exibility - reduced elongation.

Materials

• Wire & core: 316 stainless steel.

• Identifi cation system: polyamide

Description Life line anchorage support designed to allow users to connect and move around in total safety. The link with the end parts is by swaging.

Use

• Compatible with all the Evolution 8mm swaged ends.

• Use possible on every type of installation.

• High breaking strength.

• Good fl exibility – average elongation.

Materials

• Wire & core: 316 stainless steel

• Identifi cation system: Polyamide

Technique

• Breaking strength: 37 kN (8200lbs)

• Structure: 7 strands of 7 wires with steel core

• Weight: 240g / M

• Diameter: 8mm

• Swaging: min 70mm

• Operating temperature range: -40°C to +60°C (-40°F to

140°F)

• Testing: individual – ISO 9001

• Marking: CSG Identifi cation system

• Life duration: >10 years in a normal environment (annual checking recommended)

Technique

• Breaking strength: 37 kN (8200lbs)

• Structure : 7 strands of 19 wires with steel core

• Weight: 240g / M

• Diameter: 8mm

• Swaging: min 70mm

• Operating temperature range: -40°C to +60°C (-40°F to

140°F)

• Testing: individual – ISO 9001

• Marking: CSG Identifi cation system

• Life duration: >10 years in a normal environment (annual checking advisable)

Te c h n i c a l d r a w i n g

ART. # 7240211

ART. # 7240210

DPE

Line

DPE

Line

FULL BODY HARNESS

F a l l P r o t e c t i o n E x p e r t s

Standard Vest Style Harness 1102000 Canadian Model Number : 102000C. Conforms to CSA Standards

Delta No-Tangle™ design for added comfort and easy donning Spring loaded stand-up back D-ring ensures fast, easy, and safe connections Adjustable non-slip chest strap with easy to use pass-thru buckle Parachute buckles on lower shoulder straps for quick and easy adjustment Tongue buckle leg straps for fast & easy donning Polyester webbing construction for added durability Plated hardware for corrosion resistance Universal sized Meets or exceeds all applicable industry standards including OSHA, ANSI and the stringent ANSI Z359

This lightweight and easy to don harness is one of our most popular, used for general fall protection in any industry.

Every DBI/SALA harness combines maximum comfort, freedom of movement and ease of use without sacrificing safety. All harnesses are designed to securely retain you in case of a fall and distribute the impact forces throughout your body. Our exclusive Patented Delta No-Tangle™ design holds the shape of the harness, adding to your comfort, and making it easier to put on. The integrated spring loaded stand-up back D-ring is an 'industry first' and provides the user with quick connection - enhancing ease-of-use and worker productivity. Optional Delta™ Comfort pad accessory can be added for wrap-around comfort for longer hours of wear with less fatigue.

Whether you wear a harness 4 hours a day or 14 hours a day, it needs to feel good and fit right for optimum comfort, safety and productivity. DBI/SALA harnesses are designed to fit you - no matter what your size or shape!

Calcs_Product Info
FP1-4 Signed
H12 Fall Protection 1
H12 Fall Protection 2
H21 Fall Protection Drawings
833 Z701
834 Z702
835 Z703
836 Z704
837 Z705
838 Z706
839 Z707
840 Z708
841 Z709
842 Z710
843 Z711
844 Z712
845 Z713
846 Z714
847 Z715
848 Z716
849 Z717
850 Z718
851 Z719
852 Z720
853 Z721
854 Z722
855 Z723
856 Z724
857 Z725
858 Z726
859 Z727
860 Z728
861 Z729
862 Z730
863 Z731
864 Z732

File details come from the government source that posted it. Updated .