Drawings_C25864039.pdf
PDF 28 MB Posted
- Solicitation number
- 0000039134
About this file
This is a construction drawing set for the New Stokes Creek Bridge project at Malibu Creek State Park, prepared by WSP USA Inc. for the California Department of Parks and Recreation (CDPR) Angeles District. The project involves replacing an existing undersized culvert with a 70-foot clear span weathered steel bridge to restore a secondary fire escape route, reduce disruption to campers, and restore the creek to its natural configuration. The bridge is 16 feet wide and includes pedestrian and bicycle accommodations. The construction documents are at 100% completion as of August 22, 2025, with State Fire Marshal approval obtained on October 15, 2025 (Fire and Panic only). The project site is located at 1925 Las Virgenes Road, Calabasas, California 91302. Key structural elements include drilled concrete caissons for bridge abutments, four W36X stringers, reinforced concrete decking, shoring walls with soldier piles and lagging, and guardrails compliant with ADA requirements. Construction will occur while the state continues to operate park facilities, requiring coordination with campgrounds, parking areas, and district buildings. The contractor is responsible for all shoring design and bracing, environmental monitoring per specifications, tree protection measures, temporary stream diversion, erosion control, and dust control in compliance with local air quality regulations.
Design specifications reference LRFD Bridge Design Specifications (8th Edition, 2017), AASHTO guidelines, and California Building Code (2022). Foundation design is based on allowable soil end bearing pressure of 15,000 PSF and skin friction of 500 PSF into Conejo Volcanics, with bridge piles embedded minimum 5 feet into competent rock. Concrete compressive strengths range from 4,000 to 4,500 PSI depending on application. The contractor must engage a geotechnical consultant for continuous observation and testing of all grading and excavation work. All structural steel exposed to weather shall be hot-dip galvanized, with soldier beams coated with bitumastic coal tar epoxy. The contract includes requirements for temporary construction fencing, public access signage, haul route management, and a designated contractor laydown area at Reagan Ranch. Stockpile locations require state representative approval. Dust control measures must comply with City Grading Ordinance and County APCD requirements, with designated personnel monitoring compliance during all working hours including holidays and weekends. Archaeological resource protocols and native plant landscaping with a 270-day establishment period are included project requirements.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Forms_C25864039.pdf | ||
| Project_Manual_C25864039.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE MAP
DRAWING INDEX
C-0.0 COVER SHEET
C-0.1 GENERAL NOTES
C-1.0 HAUL ROUTE AND CONTRACTOR LAYDOWN AREA PLAN
C-1.1 EXISTING CONDITIONS AND DEMOLITION PLAN
C-2.0 GRADING PLAN
C-2.1 SITE LAYOUT - HORIZONTAL CONTROL PLAN
C-3.0 EROSION CONTROL PLAN
S-001 GENERAL NOTES
S-010 STRUCTURAL TYPICAL DETAILS
S-100 BRIDGE FOUNDATION PLAN
S-101 BRIDGE FRAMING PLAN
S-102 SHORING PLAN & ELEVATIONS
S-200 STRUCTURAL ELEVATION AND SECTION
S-300 STRUCTURAL DETAILS
S-301 SHORING DETAILS
LP-1 PLANTING PLAN
LP-2 OAK TREE MITIGATION PLAN
VICNITY MAP
PROJECT
SITE
PROJECT
SITE
NEW STOKES CREEK BRIDGE
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
.0
.d w g L a y o u t:
C
-0
D a te
S e p te m b e r
:5 p m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
CALIFORNIA DEPARTMENT OF PARKS AND RECREATION
(CPDR)
WSP USE INC
401 B STREET, SUITE 1650
SAN DIEGO, CA 92101
CONTACT : MIKE MAGEE
PH: (619) 338-9376
PROJECT DESCRIPTION
THIS PROJECT IS TO REPLACE AN EXISTING UNDERSIZED
CULVERT WITH A BRIDGE TO RESTORE A SECONDARY ESCAPE
ROUTE IN CASE OF FIRE, REDUCE DISRUPTION TO CAMPERS,
AND RESTORE THE CREEK TO ITS NATURAL CONFIGURATION.
DESIGN PACKAGES
30% CONSTRUCTION DOCUMENT DATE: 05-07-2018
C-0.0
MALIBU CREEK STATE PARK
C O
V E R
S H
E E T
50% CONSTRUCTION DOCUMENT DATE: 06-21-2024
CIVIL/STRUCTURAL
ENGINEER:
PROJECT OWNER:
PREPARED FOR:
PARKS DISTRICT:
& PROJECT
ADDRESS
CDPR ANGELES DISTRICT
1925 LAS VIRGENES RD
CALABASAS, CA 91302
PH: (818) 880-0363
CDPR SOUTHERN SERVICE CENTER
2797 TRUXTUN TOAD - BARRACKS 26
SAN DIEGO, CA 92106
PH: (619) 221-7060
CSFM PERMIT#: 25-S-0716-CP-DR
100% CONSTRUCTION DOCUMENT DATE: 08-22-2025
FIELD OSFM DEFERRED ITEMS
CFC CHAPTER 33 SITE FIRE SAFETY PLAN - OWNER AND
CONTRACTOR ARE TO ADHERE TO CFC CHAPTER 33 AND SITE
FIRE SAFETY PLAN PER 3303.1. THIS PLAN MUST BE VERIFIED BY
OSFM FIELD DEPUTY PRIOR TO START OF ANY CONSTRUCTION
OPERATIONS.
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
1. ALL CONSTRUCTION SHALL COMPLY WITH CURRENT APPLICABLE
CODES, ORDINANCES, REGULATIONS AND STATUTES.
2. THE PROJECT MANUAL ISSUED AS PART OF THESE CONSTRUCTION
DOCUMENTS IS AN INTEGRAL PART OF THE CONTRACT DOCUMENTS.
3. REFER TO PROJECT MANUAL, NOTICE TO CONTRACTORS FOR PREBID
JOB SHOWING REQUIREMENTS (IF APPLICABLE).
4. PROVIDE TEMPORARY CONSTRUCTION FENCING, GATE(S),
BARRICADES OR OTHER MEANS OF PROTECTING THE PUBLIC AND
PREVENTING UNAUTHORIZED ENTRY INTO CONSTRUCTION SITE.
5. MAINTAIN SAFE, CONTINUOUS PUBLIC ACCESS TO NON AFFECTED
PARK FACILITIES. TEMPORARY INTERRUPTIONS REQUIRE PRIOR
APPROVAL OF STATE’S REPRESENTATIVE AND WILL NOT BE
ALLOWED WITHOUT PROVISION FOR ALTERNATE MEANS OF ACCESS.
6. STATE WILL CONTINUE TO OCCUPY AND OPERATE PARK FACILITIES
DURING CONSTRUCTION. ANY TEMPORARY INTERRUPTION TO
UTILITIES/SERVICES REQUIRES PRIOR APPROVAL OF STATE’S
REPRESENTATIVE.
7. CONTRACTOR SHALL COMPLY WITH ALL CALIFORNIA AND FEDERAL
OSHA REQUIREMENTS FOR ALL GRADING ACTIVITIES. ALL SHORING
AND TEMPORARY BRACING IS THE RESPONSIBILITY OF THE
CONTRACTOR AND SHALL BE PLACED, AS REQUIRED, TO FACILITATE
THE WORK. CONTRACTOR SHALL RETAIN A PROFESSIONAL
ENGINEER QUALIFIED IN SHORING DESIGN. ALL SHORING AND
BRACING COSTS SHALL BE INCLUDED IN THE PROJECT BID.
8. INVESTIGATE, VERIFY AND COORDINATE WORK OF THE PROJECT
WITH EXISTING CONDITIONS AND DIMENSIONS. NOTIFY THE STATE’S
REPRESENTATIVE OF ANY CONDITION REQUIRING CLARIFICATION OR
MODIFICATION PRIOR TO PROCEEDING WITH THE AFFECTED WORK.
9. LOCATIONS OF EXISTING UNDERGROUND UTILITIES, WHERE SHOWN
ON DRAWINGS, ARE APPROXIMATE ONLY AND HAVE NOT BEEN
VERIFIED BY THE STATE OR ITS REPRESENTATIVES. DETERMINE
LOCATION OF ALL EXISTING UTILITIES AND NOTIFY & COORDINATE W/
APPLICABLE UTILITY COMPANY(IES) AND STATE’S REPRESENTATIVE
PRIOR TO COMMENCING WORK. PROTECT ALL UTILITIES TO REMAIN
AND REPAIR ANY AND ALL DAMAGES TO EXISTING UTILITIES CAUSED
BY THE CONTRACTOR’S FAILURE TO LOCATE AND PRESERVE SUCH
UTILITIES. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL POTHOLE
TO VERIFY ALL EXISTING UTILITY POINTS OF CONNECTION AND
ELEVATIONS. CONTRACTOR SHALL NOTIFY THE ENGINEER OF
RECORD OF ANY DISCREPANCIES EXISTING BETWEEN THE PLANS
AND FIELD CONDITIONS PERTAINING TO MATERIALS, ELEVATIONS,
LOCATIONS, ETC., PRIOR TO CONTINUING WORK.
10. CONTACT UNDERGROUND SERVICE ALERT (“DIG ALERT”) AT
800.227.2600 A MINIMUM OF TWO (2) WORKING DAYS IN ADVANCE OF
STARTING ANY EXCAVATION OR DIGGING.
11. REMOVE DAILY AND DISPOSE OF ALL CONSTRUCTION-RELATED
DEBRIS, RUBBISH AND WASTE MATERIAL FROM AREAS ACCESSIBLE
OR VISIBLE TO THE PUBLIC.
12. ALL DAMAGE TO EXISTING FACILITIES BY CONTRACTOR, INCLUDING
UNDERGROUND UTILITIES AND STAINING FROM EQUIPMENT LEAKS
SHALL BE REPAIRED AT CONTRACTOR’S EXPENSE.
13. ENFORCE FEDERAL AND STATE OF CALIFORNIA OCCUPATIONAL
SAFETY AND HEALTH ADMINISTRATION REQUIREMENTS AND
REGULATIONS.
14. ALL APPARENT OMISSIONS AND CONFLICTS BETWEEN COMPONENTS
OF THE DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO
THE ATTENTION OF THE STATE’S REPRESENTATIVE IMMEDIATELY
BEFORE PROCEEDING WITH ANY RELATED WORK. NO CHANGES
SHALL BE MADE UNLESS APPROVED IN WRITING BY THE STATE’S
REPRESENTATIVE.
15. ALL MATERIALS AND FINISHES SHALL BE INSTALLED OR APPLIED IN
ACCORDANCE WITH MANUFACTURER’S WRITTEN INSTRUCTIONS.
16. OBTAIN SEPARATE PERMITS AS REQUIRED FOR CONSTRUCTION OF
TRENCHES OR EXCAVATIONS WHICH ARE FIVE (5) FEET OR DEEPER
AND INTO WHICH A PERSON IS REQUIRED TO DESCEND.
17. INFORMATION SHOWN AS PROJECT AREA AND SURROUNDING AREAS
IS NOT INTENDED TO REPRESENT ACCURATE INFORMATION FOR
SUCH AREAS WHEN IT IS SHOWN AS "BACKGROUND" OR "TO
ESTABLISH ORIENTATION."
18. IN GENERAL, ANYWHERE IN THE PLANS THAT REFER TO AN ITEM
SHALL BE CONSTRUED TO MEAN FURNISH & INSTALL THAT
PARTICULAR ITEM UNLESS NOTATED THAT SUCH ITEM IS NOT IN
CONTRACT (NIC). FAILURE TO INSERT SPECIFICATION REGARDING
ITEM DOES NOT RELIEVE THE CONTRACTOR OF THE FINANCIAL
RESPONSIBILITY TO PROVIDE SUCH ITEM AND DOES NOT
CONSTITUTE A CHANGE ORDER.
19. WHERE PLANS CALL FOR "ACCESSIBLE" ITEMS, THOSE ITEMS SHALL
COMPLY WITH ALL ACCESSIBILITY NOTES AND REQUIREMENTS ON
THE G-SHEETS OF THIS PLAN SET, AND SHALL MEET ALL
REQUIREMENTS WITHIN THE AMERICANS WITH DISABILITIES ACT
(ADA).
GENERAL NOTES
1. ALL EXPORT MATERIAL SHALL BE DISPOSED OF IN AN ACCEPTABLE
LOCATION IN ACCORDANCE WITH ALL APPLICABLE
OFF-HAUL/DISPOSAL REQUIREMENTS. CONTRACTOR SHALL
PERFORM ANY REQUIRED TESTS REQUIRED BY RECEIVING
FACILITIES.
2. DUST CONTROL MEASURES SHALL BE IMPLEMENTED IN
ACCORDANCE WITH CITY GRADING ORDINANCE AND COUNTY APCD
REQUIREMENTS.
3. CONSTRUCTION CONTRACTOR SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR PROTECTION OF PUBLIC AND PRIVATE
PROPERTY ADJACENT TO THE JOB SITE AND THAT CONTRACTOR
SHALL AT THEIR EXPENSE, REPAIR OR REPLACE TO ORIGINAL
CONDITION ALL EXISTING IMPROVEMENTS WITHIN OR ADJACENT TO
THE JOB SITE WHICH ARE DESIGNATED FOR REMOVAL AND WHICH
ARE DAMAGED OR REMOVED AS A RESULT OF CONTRACTOR'S
OPERATIONS.
4. NO CUT OR FILL SLOPES WILL BE CONSTRUCTED STEEPER THAN
TWO HORIZONTAL TO ONE VERTICAL (2:1) UNLESS SPECIFICALLY
NOTED ON PLANS OR OTHERWISE APPROVED BY THE SOILS
ENGINEER.
5. MINIMUM DRAINAGE GRADIENT OF 5% IS REQUIRED FOR A MINIMUM
OF 10' AWAY FROM THE BUILDING PAD/FOUNDATION IN ACCORDANCE
WITH THE BUILDING CODES FOR LANDSCAPED AREAS ADJACENT TO
BUILDINGS (SEE CBC SECTION 1804.3).
6. ALL SURFACE AND SUBSURFACE DRAINAGE SYSTEMS DESIGNED AT
LESS THAN 2% SHALL HAVE FINAL GRADIENTS CERTIFIED BY A
LICENSED SURVEYOR OR ENGINEER PRIOR TO FINAL INSPECTION.
7. CONTRACTOR TO ENGAGE A SOILS ENGINEER/TESTING FIRM FOR
OBSERVATION AND TESTING OF GRADING ACTIVITIES. SOILS TESTS
SHALL BE DONE IN ACCORDANCE WITH THE PROJECT PLANS AND
SPECIFICATIONS. ALL TESTS SHALL CLEARLY INDICATE THE
LOCATION AND SOURCE OF THE MATERIAL.
8. COMPACTION TESTS SHALL BE MADE ON SUBGRADE MATERIAL AND
MATERIAL AS SPECIFIED BY THE ENGINEER. SAID TESTS SHALL BE
MADE PRIOR TO THE PLACING OF THE NEXT MATERIAL. GRADING AND
COMPACTION REQUIREMENTS SHOULD BE AS PER THE
RECOMMENDATIONS OF THE GEOTECHNICAL REPORT OR AS SHOWN
ON THE PROJECT PLANS, WHICHEVER IS MORE STRINGENT.
9. FINAL REPORTS SHALL BE REQUIRED IN ACCORDANCE WITH
CHAPTER 18 OF THE CBC.
10. DURING CONSTRUCTION/GROUND DISTURBING ACTIVITIES, THE
CONTRACTOR SHALL IMPLEMENT THE PARTICULATE (DUST)
CONTROL MEASURES/BMPS IN ACCORDANCE WITH THE CITY
GRADING ORDINANCE. THE CONTRACTOR SHALL DESIGNATE A
PERSON OR PERSONS TO MONITOR THE DUST CONTROL PROGRAM
AND TO ORDER INCREASED WATERING AS NECESSARY TO PREVENT
TRANSPORT OF DUST OFF SITE. THEIR DUTIES SHALL INCLUDE
HOLIDAY AND WEEKEND PERIODS WHEN WORK MAY NOT BE IN
PROGRESS. THE NAME AND TELEPHONE NUMBER OF SUCH PERSONS
SHALL BE PROVIDED TO THE APCD PRIOR TO COMMENCEMENT OF
CONSTRUCTION. USE OF WATER TRUCKS OR SPRINKLER SYSTEMS IN
SUFFICIENT QUANTITIES TO PREVENT AIRBORNE DUST FROM
LEAVING THE SITE. INCREASED WATERING FREQUENCY WOULD BE
REQUIRED WHENEVER WIND SPEEDS EXCEED 15 MPH. RECLAIMED
(NON-POTABLE) WATER SHOULD BE USED WHENEVER POSSIBLE.
11. IN THE EVENT ARCHAEOLOGICAL RESOURCES ARE DISCOVERED IN
CONJUNCTION WITH A CONSTRUCTION PROJECT, ALL ACTIVITIES
SHALL CEASE AND CONTRACTOR SHALL NOTIFY STATE'S
REPRESENTATIVE/PROJECT MANAGER SO THAT THE PROCEDURES
REQUIRED BY STATE LAW MAY BE APPLIED.
12. ALL DISTURBED SURFACES SLOPED FOUR HORIZONTAL TO ONE
VERTICAL (4:1), OR GREATER, OR AREAS USED TO CONVEY
CONCENTRATED DRAINAGE SHALL BE PREPARED AND MAINTAINED
TO CONTROL EROSION BY EFFECTIVE PLANTING TO BE COMPLETED
NO LATER THAN 30 DAYS PRIOR TO A REQUEST FOR FINAL
INSPECTION APPROVALS.
13. ALL ACTIVITIES ASSOCIATED WITH CONSTRUCTION AND OPERATION
SHALL COMPLY AT ALL TIMES WITH ALL CURRENT APCD RULES AND
REGULATIONS, AS APPLICABLE, INCLUDING, BUT NOT LIMITED TO,
PM-10, NOx EMISSIONS, BEST AVAILABLE CONTROL TECHNOLOGIES, CONSTRUCTION ACTIVITY MANAGEMENT PLANS, AND PHASING
TECHNIQUES.
14. A FIRE DEPARTMENT PERMIT IS REQUIRED IF FUEL IS TO BE STORED
ON-SITE.
15. TRACKING ONTO THE PUBLIC RIGHT-OF-WAY SHALL BE MINIMIZED.
THE ADJOINING STREET AND SIDEWALK SHALL BE CLEANED BY
SWEEPING TO REMOVE DIRT, DUST, MUD, AND ANY OTHER
CONSTRUCTION-RELATED DEBRIS AT THE END OF EACH WORKING
DAY.
GRADING NOTES
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
0000696
PC
BP
PC
F ile
L -C
A D
-A n g -9
\M a lib u C re e k \N e w S to k e s C re e k B ri d g e \L
A N D
A R
C H \C
-0 G
E N E R
A L N
O T E S
S Y M
B O
L S .d w g L a y o u t:
C
-0 G
E N E R
A L N
O T E S
S Y M
B O
L S
D a te
A u g u s t
:1 p m U s e r:
p c le w s
2025.02.18
X XX/XX/XXXX
FACILITIES AND
DEVELOPMENT DIVISION
X XX/XX/XX
X XX/XX/XX
X XX/XX/XX
X XX/XX/XX
X XX/XX/XX
XX
XX
XX
XX
XX
V2PROJECT MILESTONE: 100%-DATE 08/22/2025
PROJECT NO.
C-0.1
N E W
S T O
K E S C
R E E K B
R
ID
G E
M A L
IB
U C
R E E K S
T A T E P
A R
K
G E N
E R
A L N
O T E S
Pe nn y L . C l ews - No . 5 19 0
08/22/2025
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box 25-022 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Srikanth Rao Signature
© 2025 Microsoft Corporation © 2025 Maxar ©CNES (2025) Distribution Airbus DS
TO
E
X
X
F R
TO
E
TO
E
TOE
X
X X
X
X
X
X X
XF
R
F
FR
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
-1 .0
.d w g L a y o u t:
L a y o u t1
D a te
S e p te m b e r
:4 p m U s e r:
U
S C L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
C-1.0
CONTRACTOR LAYDOWN AREA
PROJECT AREA
HAUL ROUTE
HAUL ROUTE
LA
S V
IR
G E N E S R
D
1" = 50' scale feet
10050 0 50
H A U
L R
O U
T E C
O N
T R A C
T O
R L A Y D
O W
N A
R E A
A N
D P
U B L
IC
A C
C E S S P
L A N
CONTRACTOR'S NOTES
1. DESIGNATED CONTRACTOR'S CONSTRUCTION LAYDOWN
AREA FOR CONSTRUCTION EQUIPMENT AND MATERIAL
STAGING.
HAUL ROUTE
2. CONTRACTOR TO REMAIN WITHIN PROJECT AREA / WORK LIMITS
ONLY.
PARK ENTRANCE ROAD
3. THIS PROJECT WILL NOT ALLOW CRANE USE IN ANY PART OF
CONSTRUCTION STAGE; CONSTRUCTION EQUIPMENT USED SHALL BE
IN ACCORDANCE WITH THE MEASURES IN SECTION 000810
CONSTRAINTS AND MITIGATION AND 015639 TEMPORARY TREE AND
PLANT PROTECTION.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SIGNAGE/ROUTING
OF PUBLIC DURING CONSTRUCTION, SEE MINIMUM PUBLIC ACCESS
SIGNAGE AND TRAIL DETOUR .
5. CONTRACTOR SHALL REFER TO SPECIFICATION 000810
CONSTRAINTS AND MITIGATION FOR PERMITTING REQUIREMENTS,
SCHEDULING OF STATE MONITORING, AND OTHER ENVIRONMENTAL
CONSTRAINTS.
6. CONTRACTOR SHALL REFER TO SPECIFICATION 015639 -
TEMPORARY TREE AND PLANT PROTECTION FOR CONTRACTOR
RESPONSIBILITIES INCLUDING RETAINED ARBORIST,
PRECONSTRUCTION TREE SURVEY, MONITORING REQUIREMENTS,
HAND WORK WITHIN THE ROOT HEALTH ZONE, AND TREE
PROTECTION MEASURES.
7. CONTRACTOR SHALL REFER TO SPECIFICATION 015000 -
TEMPORARY FACILITIES AND CONTROLS FOR WORK LIMITS
DELINEATION REQUIREMENTS.
8. CONTRACTOR SHALL REFER TO SPECIFICATION 312000 - EARTH
MOVING FOR CONTRACTOR RETAINED GEOTECH REQUIREMENTS
AND TESTING.
9. CONTRACTOR SHALL REFER TO SPECIFICATION 015713 -
STORMWATER SOIL LOSS PREVENTION PLAN FOR CONTRACTOR
RETAINED QSD/QSP AND SWSLPPP REQUIREMENTS.
10. REFER TO C-3.0 EROSION CONTROL PLAN FOR PROJECT AREA
EROSION CONTROL MEASURES AND LEGEND.
11. CAMPGROUND, PARKING LOT, AND DISTRICT BUIDLINGS WILL BE
OPEN THROUGHOUT CONSTRUCTION. CONTRACTOR RESPONSIBLE
FOR SIGNAGE, SECURITY, AND COORDINATION WITH STATE'S
REPRESENTATIVE THROUGHOUT CONSTRUCTION.
12. CONTRACTOR TO STOCKPILE EXCESS SOIL MATERIAL AS
WINDROW AT REAGAN RANCH OUTSIDE OF TREE DRIPLINE AND
FUTURE ROAD EXPANSION WORK LIMITS. STOCKPILES SHALL BE SOIL
MATERIALS ONLY, COVERED, AND WITH PERIMETER CONTROL PER
CASQA WM-3 BMP. RETAIN STATE'S REPRESENTATIVE APPROVAL OF
LOCATION PRIOR TO PLACEMENT.
WAYCROSS ROAD
.0
SECURITY FENCE AND GATE
SECURITY FENCE AND GATE
LEGEND
PROJECT AREA
WAYCROSS ROAD
CONSTRUCTION ENTRANCE TC-1
SE-5
SE-5
SC-7
SC-7
SC-7
DISTRICT OFFICE
1" = 150' scale feet
300150 0 150
HAUL ROUTE
.9
CAMPFIRE CENTER TRAIL
TRAIL DETOUR
ANN SKAGER TRAIL
GATE
DIRECTIONAL SIGNAGE
FOR DETOUR TO ANN
SKAGER TRAIL
GATE
CLOSED DUE TO
CONSTRUCTION
HAUL ROUTE
HAUL ROUTE
SC-7
SC-7
PUBLIC ACCESS SIGNAGE
(ON TYPE II BARRICADE OR
EQUAL)
X
FENCE
FENCE
TRAIL DETOUR
TRAIL
CAMP GROUND
STOCKPILE LOCATION
SCALE: NTS
STOCKPILE LOCATION
PROJECT AREA
REAGAN RANCH
LAKE VISTA DR OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOE TOE
TO
E
TOE TOE
TOE
TOP
TOP TOP
TO
P
TOE
TO
E
TOE
TOE
TOE
TOP TOP
TO
P
TO
P
TOP
TOP
TOE
TOE TOE
TOE
TOE
TO
E
TOP
TO
P
T O P
T O P
T O P
TOP
TOP TOP TOP
TOE
TO
E
TOP
#755
#750
#757
#746
#745
#747
#749
#748
#751
#744
#736
#3293
#769
#773
#775
#756
#770 #771
#772
#760 #758
#759
X X X
X
X
X
X X X X X X X
X X
X
X
X
X
X
X
X X
X
X
X
X
X
X
X
XX
TOP
TOP
TOP
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
-1 .1
.d w g L a y o u t:
C
-1 .1 te
S e p te m b e r
:4 p m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
C-1.1
X X
LEGEND
DEMOLITION KEY NOTES
TREE TABLE
#775
TOP TOP
TOE
TYP
TYP
TYP
TYP
1" = 10' scale feet
20100 10
E X
IS
T
IN
G C
O N
D
IT
IO
N
S A
N D
D E M
O L
IT
IO
N
P L A N
SITE ACCESS GATE
SITE ACCESS GATE
6 6
NTSSCALE: TREE TRUNK PROTECTION
ELEVATION VIEW
PLAN VIEW (TRUNK)
2" x 6" x 8' LUMBER/WOOD
GUARD @ 12" O.C.
3" WIDE NYLON STRAP
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
.5
1.
0+ 0.
1+
.00
II
II II II II II II
II
II
II
II
II
II
II
II
II
II
II
II
II
IIII
II
II
II
II
II
II
II
II
II
IIII
II
II
II
0+00.00
1+00.00
2+00.00 2+06.86
0+50.00
1+50.00
#755
#750
#746
#745
#747
#749
#748
#751
#744
#3293
#769
#773
#775
#756
#770 #771
#772
#760 #758
#759
25.00
1.5
1.5
0+00 1+00 2+00 2+07
S T A :0
.9
E
LE
V :5
.0
S T A :0
.3
E
LE
V :5
.4
S T A :1
.5
E
LE
V :5
.4
S T A :1
.0
E
LE
V :5
.0
4.4%
3.3%
.2
.0
0+00 0+27
0+00 0+35
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
-2 .0
.d w g L a y o u t:
C
-2 .0 te
D e c e m b e r
:3 p m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
GRADING KEY NOTES
BRIDGE SECTION AT CENTER OF ROAD
SCALE: 1"=10' (H); 1"=5' (V)
A LEGEND
GUARD RAIL /
PEDESTRIAN RAILING
16'X70' WEATHERED
STEEL BRIDGE
PROP. GRADE
EX. GRADE
PROP. GRADE
EX. GRADE
1" = 10' feet
2010 10 0 scale
G R
A D
IN
G
P L A N
C-2.0
CREEK BED ELEVATION
534.50
TOP OF BRIDGE ELEVATION
552.47
100' YR STORM ELEVATION
546.13
2 4
B
PROP. GRADE
EX. GRADE
GUARD RAIL
PROP. GRADE
EX. GRADE
GUARD RAIL
SHORING WALL PER
STRUCTURAL
SECTION B
SCALE: 1"=10' (H); 1"=5' (V)
SECTION A
SCALE: 1"=10' (H); 1"=5' (V)
MATCH EX.
MATCH EX.
2 4 70.00
.0
SHORING WALL PER
STRUCTURAL
GUARD RAIL
SHORING WALL PER
STRUCTURAL
SHORING WALL PER
STRUCTURAL
II
TEMPORARY STREAM DIVERSION
BUILT-UP CONC APPROACH, TYP
BUILT-UP CONC APPROACH, TYP
BRIDGE IMPROVEMENTS
(SEE STRUCTURAL PLAN)
BRIDGE IMPROVEMENTS
(SEE STRUCTURAL PLAN)
OVER EXCAVATE 2'
BELOW BOTTOM OF PILE
CAP; RE-COMPACTED
SELECTED FILL TO 95%
RELATIVE DENSITY
OVER EXCAVATE 2'
BELOW BOTTOM OF PILE
CAP; RE-COMPACTED
SELECTED FILL TO 95%
RELATIVE DENSITY
AC PAVEMENT
PCC PAVEMENT
AC PAVEMENT
PCC PAVEMENT
PCC PAVEMENT
PCC PAVEMENT
V3
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/18/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716
Kelsey.Henck Fri Dec 12 05:17:05 2025: V3 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
C OF PILE
N:1858228.20
E:6345285.49
L
C OF PILE
N:1858224.34
E:6345293.06
C OF PILE
N:1858219.28
E:6345280.95
C OF PILE
N:1858215.43
E:6345288.53
L
L
L
L
C OF PILE
N:1858192.54
E:6345355.60
C OF PILE
N:1858191.36
E:6345364.54
C OF PILE
N:1858183.62
E:6345351.07
C OF PILE
N:1858179.77
E:6345358.65
L
L
L
END OF WALL
N:1858168.65
E:6345377.20
END OF WALL
N:1858219.72
E:6345233.78 CORNER OF WALL
N:1858219.96
E:6345268.77
END OF WALL
N:1858231.66
E:6345279.01
END OF WALL
N:1858190.59
E:6345382.38
END OF PAVEMENT
N:1858219.82
E:6345198.12
END OF PAVEMENT
N:1858233.22
E:6345199.39
END OF PAVEMENT
N:1858164.99
E:6345379.41
END OF PAVEMENT
N:1858190.33
E:6345385.53
II
II
II II II II II
II
II
II
II
II
II
II
II
II
II
II
II
II
IIII
II
II
II
II
II
II
II
II
II
IIII
II
II
II
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
-2 .1
.d w g L a y o u t:
C
-2 .1 te
S e p te m b e r
:5 p m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
1" = 10' feet
2010 10 0 scale
C-2.1
S
IT
E L
A Y O
U T
H O
R
IZ
O N
T A L C
O N
T R
O L P
L A N
SEE STRUCTURAL PLAN
FOR BRIDGE DIMENSIONS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
II
II II II II II II
II II
II
II
II
II
II
II
II
II
II
II
IIII
II
II
II
II
II
II
II
II
II
IIII
II
II
II
24" HDPE SD BYPASS PIPE
WITH 12" OF SOIL COVER
24" HDPE SD BYPASS PIPE
WITH 12" OF SOIL COVER
SE-4
EC-5/WE-1
EC-5/WE-1
EC-5/WE-1
EC-5/WE-1
ANCHOR TRENCH
ANCHOR TRENCH
ANCHOR TRENCH
ANCHOR TRENCH
SE-2
SE-2
SE-2
SE-2
SE-2
SE-2
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
CL
MM
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \C
-3 .0
.d w g L a y o u t:
C
-3 .0 te
N o ve m b e r
:1 a m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
CL
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
1" = 10' feet
2010 10 0 scale
E R
O S
IO
N C
O N
T R
O L P
L A N
C-3.0
*REFERS TO CALIFORNIA STORMWATER BMP HANDBOOK -
CONSTRUCTION (OCTOBER 2024)
DESCRIPTION SYMBOL
LEGEND
BMP*
TEMPORARY STREAM DIVERSION
CURLEX BLANKET (HIGH VELOCITY)
SCALE: NTS
2 ROWS OF STAPLES
STAGGERED, 6" O.C EA. DIR.
1 ROW OF STAPLES
STAGGERED, 12" O.C
STAPLE 12" O.C. ALONG
BLANKET AT SLOPE CHANGE
KEYED EDGE OF
BLANKET
KEY TRENCH BACKFILL AND
TAMP SOIL
HYDROSEEDED
SLOPE
V3
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/18/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716
Kelsey.Henck Fri Dec 12 05:17:41 2025: V3 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
GENERAL
1. THE FOLLOWING SPECIFICATIONS SHALL BE FOR A FULLY PRE-ENGINEERED AND
PRE-MANUFACTURED BRIDGE OF STEEL CONSTRUCTION AND SHALL BE
REGARDED AS MINIMUM STANDARDS FOR DESIGN AND CONSTRUCTION. THE
BRIDGE SUPPLIER SHALL BE PER SPECIFICATIONS.
2. DESIGN SPECIFICATIONS: "LRFD BRIDGE DESIGN SPECIFICATIONS 8th EDITION, 2017" AND AASHTO GUIDE SPECIFICATIONS FOR DESIGN OF PEDESTRIAN
BRIDGES, 2009 AND APPLICABLE INTERIMS.
3. CONSTRUCTION SPECIFICATIONS: STATE OF CALIFORNIA, DEPARTMENT OF
TRANSPORTATION "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION" 2014 EXCEPT AS NOTED BELOW AND IN THE SPECIAL
PROVISIONS FOR THIS CONTRACT.
4. SHORING DESIGN IS BASED ON THE 2022 CALIFORNIA BUILDING CODE AND THE
STATE OF CALIFORNIA TRENCHING & SHORING MANUAL, JANUARY 1990,
(UPDATED 2011) PAGES 10-1 TO 10-42 CALTRANS SHORING DESIGN GUIDE IS
USED AS A RESOURCE REFERENCE.
5. DRILL EQUIPMENT, STOCKPILING, ETC SHALL BE SET BACK A MINIMUM OF TEN
FEET FROM THE BACK OF LAGGING.
FOUNDATION
DESIGN CRITERIA
1. SUBGRADE PREPARATION, INCLUDING DRAINAGE, EXCAVATION, COMPACTION
AND FILLING REQUIREMENTS SHALL CONFORM WITH THE RECOMMENDATIONS
GIVEN IN THE SOILS REPORT AND SECTION 031200 EARTH MOVING
SPECIFICATION.
2. GEOTECHNICAL INVESTIGATION REPORT BY CONSTRUCTION TESTING &
ENGINEERING, INC. (CTE INC.), PROJECT NO. 10-132526, DATED SEPTEMBER 29,
2017. BRIDGE ABUTMENT SHALL BE SUPPORTED BY DRILLED CONCRETE
CAISSONS; DESIGN PRESSURES ARE AS FOLLOWS:
A. ALLOWABLE SOIL END BEARING PRESSURE: DEAD + LIVE LOAD = 15,000 PSF
B. ALLOWABLE SKIN FRICTION (INTO CONEJO VOLCANICS) = 500 PSF
C. ALLOWABLE PASSIVE PRESSURE:
COMPETENT COMPACTED FILL: 250 PCF, UP TO 2,500 PSF
CONEJO VOLCANICS: 400 PCF, UP TO 6,000 PSF
D. SHORING WALL DESIGN PRESSURES:
ACTIVE PRESSURE: 60 PCF FOR LEVEL BACKFILL
PASSIVE PRESSURE: 250 PCF, UP TO 2,500 PSF
SEISMIC LOADING: 28 PCF
3. REFER TO LETTER OF LIMITED SLOPE EVALUATION FOR PRESERVATION OF VALLEY
OAK TREES BY CTE INC, DATED MARCH 26, 2018.
4. DEEP BRIDGE FOUNDATIONS SHALL BE EMBEDDED 5 FEET MINIMUM INTO VERY
DENSE CONEJO VOLCANICS; GROUNDWATER AND CAVING OF BOREHOLES
SHOULD BE ANTICIPATED PER THE GEOTECHNICAL REPORT.
5. KEEP EXCAVATIONS FREE OF WATER BEFORE PLACING CONCRETE, UNLESS
OTHERWISE APPROVED BY THE SOILS ENGINEER. IF UNABLE TO SEAL OFF WATER
FLOW, PER THE APPROVAL OF THE SOILS ENGINEER, ALLOW WATER LEVEL TO
ATTAIN ITS NORMAL LEVEL AND PLACE CONCRETE BY THE TREMIE METHOD OR
OTHER APPROVED METHOD. MAINTAIN MINIMUM 5 FEET OF CONCRETE HEAD
ABOVE THE END OF THE TREMIE PIPE DURING THE ENTIRE CONCRETE PLACING
OPERATION.
6. CONTRACTOR MAY USE CASING TO MAINTAIN EXCAVATION SHAPE. WITHDRAW
CASING AS CONCRETE IS PLACED MAINTAINING A HEAD OF CONCRETE BETWEEN
5 AND 10 FEET ABOVE THE CASING BOTTOM.
7. GRADING AND EARTHWORK OPERATIONS SHALL BE CONTINUOUSLY OBSERVED
BY THE GEOTECHNICAL CONSULTANT. OBSERVATION AND TESTING IS REQUIRED
FOR CAISSON SHAFT EXCAVATION, SOIL OVEREXCAVATION, PROCESSING AND
PLACEMENT DURING GRADING.
8. WHERE GROUNDWATER IS ENCOUNTERED, CONCRETE/GROUT SHALL BE PLACED
ONLY IN DRY HOLES EXCEPT THAT WHERE GROUNDWATER IS PRESENT AND IT IS
DETERMINED THAT IT IS NOT FEASIBLE TO PUMP THE WATER FROM THE HOLES,
CONCRETE MAY BE PLACED UNDERWATER. THE CONCRETE SHALL BE PLACED BY
PUMPING THROUGH A RIGID TREMIE PIPE EXTENDING TO THE BOTTOM OF THE
HOLES.
1. DEAD LOAD: SELF-WEIGHT PLUS 3" MINIMUM FUTURE WEARING SURFACE.
2. LIVE LOAD: HL-93 LOADING and P15 (FIRE TRUCK) AND PEDESTRIAN LOADS.
3. ANTICIPATED AVERAGE DAILY TRUCK TRAFFIC (ADTT) IS < 100.
4. THE BRIDGE SHALL BE CAMBERED TO COMPENSATE FOR DEAD LOAD
DEFLECTIONS. LIVE LOAD DEFLECTION SHALL BE LIMITED TO L/500.
5. RAILING HEIGHT ABOVE THE DECK SHALL BE PER AASHTO GUIDELINES. RAILING
SHALL ACCOMMODATE PEDESTRIAN, BICYCLE, AND VEHICLE LOADING AND
COMPLY WITH ADA REQUIREMENTS.
REINFORCED CONCRETE STRUCTURAL STEEL
1. PRE-ENGINEERED BRIDGE SHALL BE FURNISHED AND INSTALLED COMPLETE,
READY FOR USE INCLUDING ALL PRIMARY AND SECONDARY STRUCTURAL
FRAMING MEMBERS, CONNECTION BOLTS, GUARDRAILS, COVERINGS, CLOSURES,
AND OTHER MISCELLANEOUS ITEMS.
2. MINIMUM BRIDGE ANCHOR BOLT DIAMETER, STEEL GRADE, AND ANCHOR
LAYOUT ARE IN INDICATED IN THESE DOCUMENTS AND SHALL BE CONFIRMED BY
THE PRE-ENGINEERED BRIDGE MANUFACTURER. IF THE BRIDGE MANUFACTURER
REQUIRES MODIFICATIONS TO THE ASSUMED DESIGN, SUBMIT CHANGES TO THE
ENGINEER OF RECORD FOR APPROVAL. ACCURATELY SET ANCHOR BOLTS WITH
TEMPLATES CORRESPONDING TO THE PRE-ENGINEERED BRIDGE
MANUFACTURER'S ANCHOR BOLT LAYOUT PLAN.
3. PRE-ENGINEERED BRIDGE SHALL BE DESIGNED BY A REGISTERED PROFESSIONAL
STRUCTURAL ENGINEER IN ACCORDANCE WITH APPLICABLE PORTIONS OF 2022
CALIFORNIA BUILDING CODE (CBC), GOVERNING CODES SHOWN ON SHEET S-001,
THE WIND, SEISMIC, DEAD AND LIVE LOADS AS SHOWN ON SHEETS S-001. THE
DESIGN CALCULATIONS AND THE PRE-ENGINEERED BRIDGE DESIGN DRAWINGS
AND SHOP DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A REGISTERED
PROFESSIONAL ENGINEER IN THE STATE OF CALIFORNIA AND MUST BE
SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR
TO STARTING FABRICATION. PRE-ENGINEERED BRIDGE ENGINEER ALSO MUST
SUBMIT ALL THE BASIC LOADINGS TO ENGINEER OF RECORD FOR THEIR REVIEW.
1. CONCRETE WORK SHALL CONFORM TO THE "REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318-19) AND SPECIFICATION 033000 CAST-IN-PLACE CONCRETE
FOR ADDITIONAL REQUIREMENTS.
2. ALL CONCRETE SURFACES, INCLUDING SLOPE PAVING SHALL BE SMOOTH. ALL
CONCRETE SURFACES, INCLUDING SLOPE PAVING, EXPOSED TO VIEW (EXCEPT
TOP SURFACE OF DECK SLAB) SHALL BE PAINTED (FINE SURFACE FINISH) WITH
SHERWIN WILLIAMS "PEWTER WORKS" TO AT LEAST 1'-0" BELOW FINISHED
GRADE. SEE NDOT SPECIFICATION SECTION 502.03.19.
3. CEMENT SHALL BE TYPE II.
4. TABULATED CONCRETE ULTIMATE COMPRESSIVE STRENGTHS ARE MINIMUM
COMPRESSIVE STRENGTH AT 28 DAYS. THE AGGREGATES SHOWN ARE THE
MAXIMUM SIZE (INCHES) AND THE SLUMP SHOWN IS THE MAXIMUM (INCHES).
CONCRETE COMPRESSIVE STRENGTH AND PROPORTIONS SHALL COMPLY WITH
ACI 318-19.
ITEM OF CONSTRUCTION (145 PCF AVG.) STRENGTH AGGREGATE SLUMP
A. ABUTMENT/PIER FOUNDATION 4,500 PSI 1" 6"
B. CONCRETE DECK 4,500 PSI 3/4" 4"
C. SHORING CAISSON 4,000 PSI 1" 4"
D. SHOTCRETE FACING 4,000 PSI 3/4" 4"
5. THE MAXIMUM ALLOWABLE WATER/CEMENT RATIO IS 0.45 AND SHALL
ACCOUNT FOR WATER FROM ALL SOURCES, INCLUDING ADMIXTURES AND THE
MOISTURE CONTENT OF THE FINE AGGREGATE. MIX DESIGNS SHOULD BE
PROPORTIONED ESPECIALLY FOR PUMPING SO AS NOT TO EXCEED THE
MAXIMUM SLUMP WHEN MEASURED. APPROVED MIX DESIGNS SHALL NOT BE
MODIFIED TO SUIT PUMPING BY THE ADDITION OF WATER.
6. STRUCTURAL CONCRETE SHALL HAVE AGGREGATES CONFORMING TO ASTM C 33
AND SHALL HAVE AN APPROVED WATER-REDUCING, NON-AIR-ENTRAINING,
ADMIXTURE ADDED, AS RECOMMENDED BY THE MANUFACTURER.
7. THE FOLLOWING REQUIREMENTS SHALL APPLY FOR CONCRETE MIX AND SHALL
BE DESCRIBED IN THE CONTRACT SPECIFICATIONS:
A. APPROVED INSPECTOR OF THE TESTING LABORATORY SHALL CHECK THE FIRST
BATCHING AT THE START OF WORK AND FURNISH MIX PROPORTIONS TO THE
LICENSED WEIGHMASTER.
B. LICENSED WEIGHMASTER TO POSITIVELY IDENTIFY MATERIALS AS TO
QUANTITY AND CERTIFY TO EACH LOAD BY A TICKET.
8. THE EVALUATION AND ACCEPTANCE OF CONCRETE SHALL CONFORM TO THE
REQUIREMENTS OF ACI 318-19.
9. CONCRETE REINFORCING STEEL SHALL BE AS TABULATED:
ITEM OF CONSTRUCTION (145 PCF AVG.) TYPE GRADE
A. ABUTMENT/PIER REINFORCING ASTM 706 60 KSI
B. CONCRETE DECK ASTM 706 60 KSI
C. SHOTCRETE FACING ASTM 615 60 KSI
10. REINFORCING DETAILING SHALL CONFORM TO THE CONCRETE REINFORCING
STEEL INSTITUTE "MANUAL OF STANDARD PRACTICE" LATEST EDITION.
11. REINFORCING STEEL SHOP DRAWINGS SHALL BE REVIEWED BY THE STRUCTURAL
ENGINEER PRIOR TO FABRICATION.
12. MINIMUM PROTECTIVE CONCRETE COVERAGE OF REINFORCING AND TIES:
A. ON EARTH SIDE WHEN PLACED AGAINST EARTH.............................. 3 IN
B. ON EARTH SIDE WHEN FORMED...................................................... 2 IN C. EXTERIOR WALL STEEL ABOVE GRADE ............................................ 1 IN
13. CONTINUOUS INSPECTION BY AN INSPECTOR APPROVED BY THE GOVERNING
AGENCY IS REQUIRED FOR ALL STRUCTURAL REINFORCED CONCRETE WORK OF
fc' = 3,000 PSI OR GREATER (NOT REQUIRED FOR LEAN CONCRETE).
14. REINFORCING, ANCHOR BOLTS AND ALL OTHER EMBEDDED ITEMS SHALL BE
SECURELY HELD IN POSITION AND SHALL BE INSPECTED PRIOR TO PLACING
CONCRETE.
15. CHAMFER: 3/4" ON ALL EXPOSED CORNERS AND EDGES.
16. ANCHOR BOLTS SHALL BE TIED IN PLACE PRIOR TO PLACING CONCRETE.
17. ANCHOR RODS SHALL COMPLY WITH ASTM F1554, GRADE 105, U.N.O.
18. ANCHOR RODS EXPOSED TO THE WEATHER SHALL BE HOT DIP GALVANIZED.
CONSTRUCTION NOTES
1. STRUCTURAL STEEL FOR THE SUPERSTRUCTURE SHALL CONFORM TO ASTM
A709, GRADE 50, ASTM A1085, OR ASTM A500 (ASTM A500 SHALL MEET
CHARPY TOUGHNESS REQUIRED FOR ZONE: 2) SEE SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. SOLDIER BEAMS SHALL COMPLY WITH ASTM A992 (FY=50KSI) NOTED AS H.S.
3. STRUCTURAL STEEL SUPERSTRUCTURE AND GUARDRAIL FRAMING
PERMANENTLY EXPOSED TO WEATHER SHALL BE PAINTED FINISH, IN
ACCORDANCE WITH THE SPECIFICATIONS. STRUCTURAL COMPONENTS AND
CONNECTIONS EXPOSED TO WEATHER SHALL BE CORROSION PROTECTED BY
BEING HOT-DIPPED GALVANIZED.
4. SOLDIER BEAMS PART OF THE PERMANENT WALL SHALL BE COATED WITH
BITUMASTIC COAL TAR EPOXY TO A MINIMUM DRY THICKNESS OF 16 MILS.
EPOXY SHALL BE APPLIED TO A CLEAN BEAM (SAND BLASTED TO NEAR WHITE).
BEAMS SHALL BE COATED FOR THEIR FULL CUT HEIGHT, EXCLUDING
GUARDRAIL, AND A MINIMUM OF 4'-0" INTO THE STRUCTURAL CONCRETE
CAISSON, AND THE BOTTOM 4'-0". IF MIN 3" CLEARANCE IS NOT MAINTAINED
FROM EDGE OF CAISSON TO ANY PART OF BEAM, ENTIRE BEAM SHALL BE
EPOXY COATED. PERMANENT ANGLES, PLATES AND MISCELLANEOUS STEEL
SHALL COMPLY WITH ASTM A-36 AND SHALL BE EPOXY COATED.
5. NO PENETRATIONS SHALL BE PLACED IN STEEL MEMBERS UNLESS
SPECIFICALLY SHOWN AND DETAILED ON THE STRUCTURAL DRAWINGS.
6. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH AISC AND AWS.
7. WELDING SHALL BE DONE IN ACCORDANCE WITH THE A.W.S. STANDARD AWS
D1.1. ALL WELDING SHALL BE BY THE ARC WELDING PROCESS USING E-70
ELECTRODES. THE USE OF E70T-4 IS PROHIBITED.
8. FILLER METAL USED IN ARC WELDING SHALL BE IN ACCORDANCE WITH TABLE
4.1.1 OF AWS D1.1. THE MIN. TENSILE STRENGTH FOR FILLER METAL SHALL BE
70 KSI.
H (KIPS) L (KIPS)
PROVIDED BY CONTECH ENGINEERED SOLUTIONS INC.
(-) INDICATES UPWARD LOAD
P (KIPS)
DEAD LOAD
UNIFORM LIVE LOAD
HL-93 VEHICLE LOAD
P15 VEHICLE LOAD
WIND
SEISMIC LOAD
THERMAL LOAD
BRAKING FORCE
BRIDGE ABUTMENT REACTIONS
106/(R=1) = 106
2x106/(R=1) = 212
"P" - VERTICAL LOAD AT EACH BASE PLATE (4 PER BRIDGE)
"H" - HORIZONTAL LOAD AT EACH ABUTMENT, TRANSVERSE TO BRIDGE SPAN
DIRECTION (2 PER BRIDGE)
"L" - LONGITUDINAL LOAD AT EACH FIXED END ABUTMENT, ALONG THE BRIDGE
SPAN DIRECTION (1 PER BRIDGE)
-12
1. DELIVERY OF THE BRIDGE SHALL BE MADE BY THE MANUFACTURER TO THE
LOCATION OF THE BRIDGE SITE.
2. CONTRACTOR SHALL SPLICE AND INSTALL THE BRIDGE SUPERSTRUCTURE AS PER
MANUFACTURER'S REQUIREMENTS.
3. CONTRACTOR SHALL REPORT ANY DISCREPANCIES TO THE STATE BEFORE
CONTINUING WITH THE CONSTRUCTION OF STRUCTURAL MEMBERS/UTILITIES
AND DETAILS VARY FROM THAT INDICATED ON DRAWINGS.
4. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS, METHODS AND
SEQUENCING OF REMOVALS AND CONSTRUCTION OF STRUCTURE. CONTRACTOR
SHALL DESIGN AND PROVIDE SHORING SUPPORT AND/OR BRACING TO SUPPORT
NEW CONSTRUCTION (VERTICALLY AND LATERALLY) UNTIL STRUCTURAL
COMPONENTS HAVE BEEN CONNECTED AS SHOWN ON THE STRUCTURAL
DRAWINGS AND IN ACCORDANCE WITH THE SPECIFICATIONS.
5. ALL VEGETATION REMOVAL ACTIVITIES SHALL BE CONDUCTED OUTSIDE OF BIRD
BREEDING SEASON TO THE EXTENT PRACTICABLE. VEGETATION TO BE PROTECTED
WILL BE MARKED AND PROTECTED BY TEMPORARY FENCING OR OTHER
ACCEPTABLE METHOD.
6. THE CONTRACTOR SHALL CONTACT THE STATE'S REPRESENTATIVE A MINIMUM
AT 7 CALENDAR DAYS PRIOR TO THE START OF CONSTRUCTION.
7. VEGETATION REMOVAL AND ANY GROUND DISTURBING WORK TO SCHEDULE
CULTURAL AND/OR NATURAL RESOURCE MONITORING, SEE SECTION 000810 AND
SECTION 015639.
8. ALL WORK WITHIN TREE PROTECTION ZONE AND UNDERNEATH CANOPY TO
ADHERE TO SECTION 015639. CONTRACTOR TO RETAIN SERVICES FROM A
CERTIFIED ARBORIST TO COMPLY WITH REQUIREMENTS, AS OUTLINED IN THE
SECTION.
6. CONSTRUCTION OF THE CONCRETE DECK SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR. THE GALVANIZED DECK FORM AND DESIGN OF THE CAST-IN-PLACE
CONCRETE DECK SHALL BE THE RESPONSIBILITY OF THE BRIDGE MANUFACTURER.
CONTRACTOR SHALL INSTALL GALVANIZED DECK FORM PER BRIDGE
MANUFACTURER'S REQUIREMENTS.
7. THE BRIDGE MANUFACTURER SHALL BE RESPONSIBLE FOR THE DESIGN AND
DETAILING OF BEARING PLATES AND FOR THE STEEL STRENGTH OF THE ANCHOR
BOLTS. BOLT EMBEDMENT DEPTH AND CAPACITY IN CONCRETE WILL BE
DETERMINED BY THE STRUCTURAL ENGINEER OF RECORD.
8. THE BRIDGE MANUFACTURER SHALL SUBMIT DESIGN CALCULATIONS AND
COMPLETE PLANS OF THE SUPERSTRUCTURE FOR REVIEW BY THE STRUCTURAL
ENGINEER. CALCULATIONS AND PLANS SHALL BE SIGNED AND SEALED BY AN
ENGINEER LICENSED TO PRACTICE CIVIL ENGINEERING IN THE STATE OF
CALIFORNIA.
9. THE SUPERSTRUCTURE REACTIONS AT ABUTMENTS AND PIERS SHALL BE
SEPARATED INTO DEAD LOAD, LIVE LOAD, WIND LOAD, AND EARTHQUAKE LOAD.
THE SUBSTRUCTURE IS DESIGNED TO SUPPORT NO MORE THAN ONE PINNED END
OF THE BRIDGE SUPERSTRUCTURE. THE BRIDGE SUBSTRUCTURE IS DESIGNED FOR
THE FOLLOWING LOAD:
10. SEISMIC LOADS: (LAT: 34.096176°, LONG: -118.714459°)
A. PEAK GROUND ACCELERATION (PGA) = 0.811g
B. SITE CLASS = D
C. SHORT PERIOD SPECIAL ACCELERATION COEFFICIENT, Ss = 2.097g D. ONE-SECOND PERIOD SPECIAL ACCELERATION COEFFICIENT, S1 = 0.735g E. SEISMIC COEFFICIENT, Fa = 1.0 F. SEISMIC COEFFICIENT, Fv = 1.5 G. DESIGN SPECTRAL RESPONSE ACCELERATION, SDS = 1.398g H. DESIGN SPECTRAL RESPONSE ACCELERATION, SD1 = 0.735g
PRE-ENGINEERED BRIDGE NOTES
DESIGN CRITERIA (CONT)
1. LUMBER SHALL BE DOUGLAS FIR/LARCH (NORTH) PRESSURE TREATED FOR
GROUND CONTACT AND SHALL BE GRADE MARKED #2 OR BETTER.
2. PERMANENT LAGGING (AND LAGGING ABANDONED IN PLACE WHERE COVERED
BY SHOTCRETE) SHALL BE TREATED IN ACCORDANCE WITH AWPA U1
(COMMODITY SPECIFICATION A, USE CATEGORY 4B) USING 'PRESERVE ACQ'
(ALKALINE COPPER QUATERNARY) PRESERVATIVE SOLUTION.
TIMBER
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-0 .d w g L a y o u t:
S
-0
D a te
S e p te m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-001
G E N
E R
A L N
O T E S
SEB
SEB
KS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
ISOMETRIC VIEW SECTION VIEW
2'- 0"
1'- 0"
C S
UPP
ORT
BE
AM
L DECK
ATTACHMENT
SUPPORT
BEAM
GALV. FORM
(BY CONTECH)
SHEAR STUDS AS REQ'D
DECK END CLOSURE
DECK
GALV. FORM DECK
(C O V E R
(C O V E R
12"
DISTRIBUTION
REINFORCEMENT
TYPICAL BEARING DETAIL1
SCALE: NTS
TYPICAL FORM DECK DETAIL2
SCALE: NTS
FORM DECK DETAILS 3
SCALE: NTS
CONCRETE DECK REINFORCEMENT4
SCALE: NTS
(M
IN LA
P)
FORM
DECK
GALVANIZED
FORM DECK
ATTACH DECK USING POWDER
ACTUATED FASTENERS OR ARC
SPOT PUDDLE WELDS. (24"
MAX SPACING) MAIN REINFORCEMENT
(PERPENDICULAR TO TRAFFIC)
PLATE WASHER
(BY BRIDGE MFR)
1" BEARING PLATE
(BY BRIDGE MFR)
ELASTOMERIC
BEARING PAD
(BY BRIDGE MFR)
1/2" SETTING PLATE
1" LEVELING GROUT
1 1/4" ANCHOR
BOLTS
DOUBLE NUT
WX STRINGER
(BY BRIDGE MFR)
M
IN
16" MIN (LONGITUDINAL)
6" MIN (TRANSVERSE)
TOP OF ABUTMENT
ELEVATION PER PLAN
@ FREE BEARING:
SLOTTED HOLE (BY
BRIDGE MFR)
@ FIXED BEARING:
STANDARD HOLE
*NOTE: DECK AND FORM THICKNESS TO BE DETERMINED BY BRIDGE MANUFACTURER.
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-0 .d w g L a y o u t:
S
-0
D a te
S e p te m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S T R
U C
T U
R A L T
Y P
IC
A L D
E T A
IL
S
S-010
SEB
SEB
KS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
1/4" = 1'-0" feet
84 4 0 scale
FOUNDATION PLAN1
SCALE: 1/4"=1'-0"
BRIDGE OUTLINE ABV
±70'-2" (BETWEEN PILES)
2'-10"Ø PILE
BLW, TYP
S-200
S-200
S-300
CONC ABUTMENT
CONC ABUTMENT
PILE CAP
8'-6"
S-300
2'-0" 2'-0"8'-6" 2'-0" 2'-0"
T Y P
T.O. ABUTMENT = 548.86
T.O. ABUTMENT = 548.86
S-300
S-300
S-300
S-300
CONTRACTOR DESIGNED SHORING
TOWER, OFFSET TO ACCOMMODATE
LENGTH OF BOTTOM FLANGE
SPLICE. COORDINATE WITH BRIDGE
DRAWINGS, TYP.
S-102
S-102
1'-11" 1'-11"
FO WALL
FO WALL DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-1 .d w g L a y o u t:
S
-1
D a te
S e p te m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-100
B R
ID
G
E F
O U
N D A T
IO
N P
L A N
SEB
SEB
KS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
70'-0" PRE-ENGINEERED BRIDGE CLEAR SPAN
℄ FREE
BEARING
℄ FIXED
BEARING
℄ ALIGNMENT
7" 7"68'-10" ℄ TO ℄ BEARING
10'-7"10'-7"
1/4" = 1'-0" feet
8 4 4 0 scale
CONC DECK
FRAMING PLAN1
SCALE: 1/4"=1'-0"
BUILT UP
APPROACH
WALL OVER
PILE CAP
S-200
S-200
W36X STRINGER,
TYP. OF (4)
±22'-0" (BY BRIDGE MNFR) ±22'-0" (BY BRIDGE MNFR)
CONTRACTOR DESIGNED SHORING
TOWER, OFFSET TO ACCOMMODATE
LENGTH OF BOTTOM FLANGE
SPLICE. COORDINATE WITH BRIDGE
DRAWINGS, TYP.
STRINGER SPLICE
PER BRIDGE
MANUF, TYP.
EDGE OF PILE
CAP BLW
EDGE OF WALL
S-300
S-300
S-300
S-300
S-300
S-300
S-300
S-300
SLOPE DOWN
PER CIVIL
SLOPE DOWN
PER CIVIL
SHORING
CAISSONS BLW
PER S-100, TYP.
ASPHALT
PAVEMENT PER
CIVIL, TYP.
S P A C E S
℄ STRINGER,
TYP.
DIAPHRAGM
(BY BRIDGE
MFR), TYP.
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-1 .d w g L a y o u t:
S
-1
D a te
S e p te m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-101
B R
ID
G E F
R A M
IN
G
P L A N
SEB
SEB
KS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
S-1
S-10
S-100
S-3
S-30
S-301
TYP.
NOTE: CONSERVATIVE T.O.S. IS PROVIDED
FOR BIDDING PURPOSES. GC TO
COORDINATE REQUIRED T.O.S. BASED ON
CIVIL T.O.W. AND EXISTING GRADE AT EACH
POINT ALONG THE WALL. T.O.S. ABOVE THE
FINISHED SURFACE OF THE APPROACH WILL
NEED TO BE COPED PER DETAIL 8/S-301.
8 9 10
S-102
S-10
S-301
S-30
S-301
TYP.
B.O.W. = 549.00'
BOTTOM OF EXCAVATION
CONCRETE CAISSON
PER SCHEDULE
B.O.W. = 548.00'
CUT HEIGHT PER
SCHEDULE
E M
B E D M
E N T
P E R S C H E D U
LE
42'-0"±
6 SPACES @ 6'-0" O.C. = 36'-0"±
5 4 3 2
3X12 WOOD LAGGING
PER DETAILS, TYPICAL
U.N.O.
6 7
T.O.S. = 552.00' T.O.S. = 553.00'
T.O.S. = 551.00'
SOUTHWEST ELEVATION4
SCALE: 1/8"=1'-0"
(E) 1H:1V SLOPE,
FV PER CIVIL
FINISHED SURFACE
PER CIVIL
BOTTOM OF EXCAVATION
CONCRETE CAISSON
PER SCHEDULE
B.O.W. = 549.00'
CUT HEIGHT PER
SCHEDULE
E M
B E D M
E N T
P E R S C H E D U
LE
18'-0"±
3X12 WOOD LAGGING
PER DETAILS, TYPICAL
U.N.O.
T.O.S. = 552.00'
6'-0"± 6'-0"±
T.O.S. = 553.00'
SOUTHEAST ELEVATION5
SCALE: 1/8"=1'-0"
B.O.W. = 550.50'
(E) 2H:1V SLOPE,
FV PER CIVIL
FINISHED SURFACE
PER CIVIL
SHORING PLAN1
SCALE: 1/4"=1'-0"
T.O.S. = 552.50'
BOTTOM OF EXCAVATION
CONCRETE CAISSON
PER SCHEDULE
B.O.W. = 550.50'
CUT HEIGHT PER
SCHEDULE
E M
B E D M
E N T
P E R S C H E D U
LE
18'-0"±
11 12
6'-0"±6'-0"±
NORTHEAST ELEVATION3
SCALE: 1/8"=1'-0"
T.O.S. = 553.00'
B.O.W. = 549.00'
FINISHED SURFACE
PER CIVIL
NORTHWEST ELEVATION 2
SCALE: 1/8"=1'-0"
BOTTOM OF EXCAVATION
CONCRETE CAISSON
PER SCHEDULE
B.O.W. = 550.00'
CUT HEIGHT PER
SCHEDULE
E M
B E D M
E N T
P E R S C H E D U
LE
18'-0"±
3X12 WOOD LAGGING
PER DETAILS, TYPICAL
U.N.O.
T.O.S. = 552.50'
6'-0"± 6'-0"±
T.O.S. = 553.00'
B.O.W. = 551.00'
FINISHED SURFACE
PER CIVIL
1/4" = 1'-0" feet
84 4 0 scale
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-1 .d w g L a y o u t:
S
-1
D a te
S e p te m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-102
S H
O R
IN
G P
L A N
E
L E V A T
IO
N S
SEB
SEB
KS
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
10/15/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
70'-0" PRE-ENGINEERED BRIDGE (BY BRIDGE MNFR)
CONC
ABUTMENT
PER
BRIDGE ELEVATION1
SCALE: 1/4"=1'-0"
-CONC DECK
RIDGE EL = 552.47
STRINGER
S-300 GUARD RAIL
34"Ø CIP CONCRETE PILE,
EMBED 5'-0" MINIMUM INTO
CONEJO VOLCANICS, TYP.
BUILT-UP APPROACH,
COORDINATE FINISH
ELEVATION PER CIVIL.
FILL W/CONCRETE, SLURRY,
OR COMPACTED FILL.
EPOXY COATED
SHORING BM @ 6'-0"
O/C W/ W6X15
GUARDRAIL BOLTED
TO SIDE OF
SHOTCRETE, TYP.
24"Ø CONCRETE
CAISSON PER
SCHEDULE, TYP.
W6X15 GUARDRAIL
BOLTED TO SIDE OF
BUILT-UP CONCRETE, TYP.
24" TEMPORARY HDPE SD
BYPASS PIPE WITH 1'-0" OF
SOIL COVER, PER CIVIL
±22'-0" (BY BRIDGE MNFR) ±22'-0" (BY BRIDGE MNFR)
CONTRACTOR DESIGNED SHORING
TOWER, OFFSET TO ACCOMMODATE
LENGTH OF BOTTOM FLANGE SPLICE.
COORDINATE WITH BRIDGE DRAWINGS
STRINGER SPLICE PER
BRIDGE MNFR, TYP.
CREEK BED
EL = 534.50
T.O. ABUTMENT/PILE
EL = 548.47, TYP.
10'-0" MIN TO TOP
OF EMBEDMENT, TYP.
E M
B E D
T Y P
P
IL
E
APPROXIMATE
GROUNDWATER
PER GEOTECH
APPROXIMATE
CONEJO VOLCANICS
PER GEOTECH
EL = 529.50
EL = 523.00
EL = 527.50
EL = 527.00
M
IN
M
IN
RAIL TO MATCH TYPE
AND CONNECTION
PER BRIDGE MFR, TYP. 3" MAX
GAP, TYP.
S-300
SHORING
T.O.S. PER
S-102
L6XL6X
S-301
S-301
MAX T.O.W.
EL = 552.47
68'-10" ℄ BEARING TO ℄ BEARING
℄ FREE
BEARING
℄ FIXED
BEARING
1.5
1.5
100 YR STORM
EL = 546.13
S-102
EL = 548.00
EL = 549.00
S-102
*NOTE: COORDINATE DEPTH
INTO CONEJO WITH TYPICAL
PILE EMBEDMENT
BRIDGE SECTION2
SCALE: 1/2"=1'-0"
CONC OVER METAL
DECK (BY BRIDGE MFR)
16'-0"
W36X STRINGER
(BY BRIDGE MFR),
TYP
SIDE DAM
(BY BRIDGE MFR)
DIAPHRAGM
(BY BRIDGE MFR)
-1.5%-1.5%
8'-0" 8'-0"
℄ ALIGNMENT
PROFILE
GRADE LINE
GUARD RAIL, TYP.
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\U S C
L \W
S P O
\S a n D ie g o P ro je c ts
\3
\0
\C
A D
D \D w g s \S
-2 .d w g L a y o u t:
S
-2
D a te
N o v e m b e r
:4 a m U s e r:
U
S C
L
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-200
S T R
U C
T U
R A L E
L E V A T
IO
N A
N D
S E C
T
IO
N
SEB
SEB
KS
V3
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/18/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716
Kelsey.Henck Fri Dec 12 05:17:35 2025: V3 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
TYPICAL BRIDGE ABUTMENT DETAIL4
SCALE: 1"=1'-0"
34"Ø
V A R
IE
S
W36X STRINGER
PER PLAN
CONC DECK
(BY BRIDGE
MFR)
BUILT-UP CONCRETE
APPROACH
ABUTMENT PILE
CAP PER
ABUTMENT
PILE
PILECAP
PER
34"Ø CONC PILE
VERT BARS
PER
TYPICAL ABUTMENT/PILE REINFORCING
SCALE: 1"=1'-0"
PILE REINFORCING PLAN
SCALE: NTS
TYPICAL ABUTMENT REINFORCING3
SCALE: 1"=1'-0"
PILECAP
#9 @ 8" O/C T&B
#4 @ 8" O/C
(2) #6 EA FACE
#5 @ 10" HORIZ
#5 @ 10" EA FACE
C
LR
T Y P
M
IN
O /C
C
IR
C U
LA
R T
IE
S
C
LR
T Y P
M
IN
E M
B E D I N T O C
O N E
JO
V O
LC
A N
IC
S P
E R S O
IL
R
E P O R T
M
IN
/2 O /C
C
IR
C U
LA
R T
IE
S
1 1/2" MIN
1'-0"
CONT KEY, T&B
(CONCRETE NOTE #19)
12" SOG W/ #6 @ 5"
O/C EA WAY, SLOPE PER
CIVIL
COMPACTED
SUBGRADE PER
GEOTECH REPORT
BUILT-UP
APPROACH
PER
℄ CAISSON
PER FOUNDATION
PLAN
FACE OF WALL
S-010
PER FOUNDATION
PLAN
℄ CAISSON
PER PLAN
0 @ SIM
GRADE
PER CIVIL
TYPICAL GUARDRAIL AT ABUTMENT5
SCALE: 1"=1'-0"
PILECAP
1'-0"
COMPACTED
SUBGRADE PER
GEOTECH REPORT
SOG
NOTE: FOR INFORMATION
NOT SHOWN OR NOTED,
SEE
W6X15 GUARD @ 8'-0"
O/C MAX, WHERE
OCCURS PER ELEVATION
M
IN 2
1/2"Ø SS THD ROD EA SIDE
OF WEB (4" HORIZONTAL
SPACING), EMBED 8" INTO
HILTI RE-500 V3 (6
ANCHORS TOTAL)
RAIL PER
STD HOOKS, TYP.
@ VERT REINF
(ROTATE TO FIT)
2'-8" #6 SUPPLEMENTAL ANCHOR
REINFORCING. LOCATE 1 BAR ON
EA SIDE OF ANCHOR, SPACED 1
3/4" FROM ANCHOR CENTERLINE
(4 TOTAL @ EA BEARING PLATE)
NOTE: FOR INFORMATION
NOT SHOWN OR NOTED,
SEE
#9 CONT
#6 HAIRPIN X 54"
SUPPLEMENTAL REINFORCING.
LOCATE @ OUTERMOST
ANCHORS ONLY W/ OPEN END
FACING THE INTERIOR
(2 TOTAL EA ABUTMENT)
COVER PL
(BY BRIDGE MFR)
T.O. ABUTMENT
SEE 1/S-200
C
LR
B.O. CAISSON
EL = 518.00
T.O. ABUTMENT
SEE 1/S-200
T.O. ABUTMENT
SEE 1/S-200
T.O. ABUTMENT
SEE 1/S-200
SOG
C
LR
7"
℄ BEARING
34"Ø CONC PILE
CIRCULAR TIES PER
EL (ALT 135° HOOK
LOCATIONS)
(12) #14 VERT
REINF
3" CLR,TYP
S-301
DPR ACCESS COMPLIANCE REVIEW
ACCESSIBILITY SECTION
SHEET NO.
OF
DRAWN:
REVISIONS
CHECKED:
DATE
DESIGNED:
DATE:
CERTIFICATION #
Reviewed by Date
F ile
C
U s e rs
\u s s b \W
S P O
\S a n D ie g o P ro je c ts
\0
\C
A D
D \D w g s \S
-3 .d w g L a y o u t:
S
-3
D a te
N o v e m b e r
:5 p m U s e r:
u s s b
N E W
S T O
K E S C
R E E K B
R
ID
G E
08-22-2025
FACILITIES AND
DEVELOPMENT DIVISION
V2
PROJECT NO.
WSP USA Inc.
401 B STREET, SUITE 1650
San Diego, CA 92101
TEL: (619) 338-9376
0000696
M A L
IB
U C
R E E K S
T A T E P
A R
K
S-300
S T R
U C
T U
R A L D
E T A
IL
S
SEB
SEB
KS
V3
OFFICE OF THE STATE FIRE MARSHAL
shall be available on the project site at all times.
12/18/25
APPROVED FIRE AND PANIC ONLY
Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans
25-0716
Kelsey.Henck Fri Dec 12 05:17:18 2025: V3 srao Text Box Srikanth Rao, CASp-927 srao Text Box 1/13/26 srao Text Box 25-022
VARIES SEE ELEV.
SOLDIER PILE PLAN DETAIL
SCALE: N.T.S.
3" BEARING
MIN
EPOXY COATED SOLDIER
PILE PER SCHEDULE
TIMBER LAGGING PER
ELEVATIONS, TYP
BACKFILL ALL VOIDS BEHIND
LAGGING PRIOR TO START OF NEXT
5-0" EXCAVATION STAGE, SEE
GENERAL NOTES FOR ACCEPTABLE
BACKFILL MATERIAL
DRILLED SHAFT,
DIAMETER PER SCHEDULE.
(BACKFILL WITH CONCRETE OR LEAN
CONCRETE, PER DETAILS)
SOIL RETAINED
#5 @ 10" O.C. CONTINUOUS
HORIZONTAL
#5 @ 12" O.C.
VERTICAL
E Q
M
IN
GEOCOMPOSITE DRAIN
BOARD PER
3/4"Ø x 6" SELF-FLUXING STUD @ 10" O.C.
INSTALLED AND TESTED PER
MANUFACT…
This is the start of the file's text. The full file is on GovTribe.