Drawings - BW Exterior Stairs.pdf
PDF 2 MB Posted
- Solicitation number
- CRFQ-0310-DNR2500000013-1
- Issued by
- Tucker County, West Virginia
About this file
These are architectural construction documents for the Blackwater Falls Lodge Exterior Stair Repair/Replacement project located at 1584 Blackwater Lodge Rd, Davis, WV 26260. The project involves repairing and replacing exterior stairs at two locations (north and south) of the lodge, with detailed design specifications for structural modifications, stair configurations, handrails, guardrails, and painting requirements. The documents, prepared by Paradigm Architecture and dated 12-4-2024, include comprehensive drawings showing existing conditions, proposed stair layouts, structural details, material specifications, and installation instructions for new precast stairs, supports, and related architectural elements.
The project includes specific technical requirements such as priming and painting all exposed metal surfaces with two coats of semi-gloss exterior paint, building new CMU support walls with stone veneer, installing new concrete slab footings, and trimming existing steel beams. The construction documents provide precise measurements, material specifications, and installation guidelines, indicating a thorough approach to replacing the exterior stairs while maintaining the aesthetic and structural integrity of the Blackwater Falls Lodge. The job number for this project is 2420, with the design firm Paradigm Architecture collaborating with Allegheny Design Services, LLC as the structural engineer.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Final_CRFQ_0310_DNR2500000013_1_WV_CRFQ_FORM.PDF | ||
| Solicitation Docs 4-30-2025.pdf | ||
| Plans - BW Exterior Stairs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SUMMARY OF ALTERNATES
BASE BID:
ALL WORK ASSOCIATED WITH THE NORTH STAIR.
1.
ALT NO. DESCRIPTION
ALL WORK ASSOCIATED WITH THE SOUTH STAIR.
Date:
Job Number:
set no.
©COPYRIGHT 2025
PARADIGM ARCHITECTURE
ARCHITECT
PARADIGM ARCHITECTURE
5184 Caldwell Mill Road · Suite 204351
Hoover, AL 35244 Tele 205·403·2742
2223 Cheat Road · Suite 300 Morgantown, WV 26508
Tele 304·284·5015 304·284·5014 Fax
STRUCTURAL ENGINEER
ALLEGHENY DESIGN
SERVICES, LLC
102 Leeway Street Morgantown, WV 26505
Tele 304·599·0772 304·599·0771 Fax
C U se rs
\a e w .P
A R
A D
IG
M
A R
C H
\D o c u m e n ts
\2
_A rc h _C e n tr a l_ a a ro n w h it e
.r vt
12.4.2024
Blackwater Falls Lodge Exterior Stair Repair/ Replacement
1584 Blackwater Lodge Rd, Davis, WV 26260
/1
/2
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
CONSTRUCTION DOCUMENTS
N
VICINITY MAP
LOCALITY MAP
Drawing Index with Revisions
Sheet No. Sheet Name Revision Revision
Date Revision Description
General G0.00 Cover 1 3.14.2025 Add Alternate
Structural
S001 GENERAL NOTES
S100 NORTH STAIR PLAN
Architectural A0.00 Abbreviations, General Notes, Details A1.00 Area of Work Plan A2.00 South Stair A2.01 North Stair A6.00 Sections & Details
1.
2.
3.
4.
A.
5.
6.
7.
8.
9.
GENERAL STRUCTURAL NOTES:
Should a discrepancy occur between the construction drawings and the project technical specifications in the Project Manual, the specifications (including geotechnical report) will govern.
Design Code: IBC 2015, Risk Category II
No provisions have been made for future horizontal or vertical expansion.
Wind Design Data:
Ultimate 3-Second Gust Design Wind Speed: 109 mph Nominal 3-Second Gust Design Wind Speed: 75 mph Wind exposure classification: B
Design wind pressure for exterior components: 25 psf
Earthquake Design Data:
Seismic Importance Factor, IE = 1.00 Mapped spectral response acceleration parameters:
SS =0.103, S1 = 0.049
Design spectral response acceleration parameters:
SDS =0.11, SD1 = 0.078
Seismic Site Class: D Seismic Design Category: B Basic Seismic Force Resisting System:
Ordinary Steel Braced and Moment Frames Seismic Response Coefficient, Cs: 0.0367 Response Modification Coefficient, R: 3.0
Analysis Procedure Used:
Equivalent lateral force procedure
Live Load data:
Uniform Floor Live Loads:
Location Load Stairs 100 psf Balcony 100 psf Concentrated Floor Live Loads (distributed over an area 2-1/2 sq. ft., unless noted otherwise):
Office Buildings: 2000 lbs
Handrail:
Top Rail: 200 lb. or 50 lb/ft applied non-concurrently in any direction.
Snow load data:
Ground Snow Load, Pg = 40 psf Flat Roof Snow Load, Pf = 40 psf (min) Snow Exposure Factor, Ce = 1.0 Thermal Factor, Ct = 1.2 Snow Load Importance Factor, Is = 1.0
General Contractor shall verify all dimensions and conditions related to existing construction, existing services, and the site.
Construction loads shall not exceed design live loads. Shoring and re-shoring is the responsibility of the General Contractor.
1.
2.
a.
b.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
CAST-IN-PLACE CONCRETE:
Cast-in-place concrete work shall conform to the American Concrete Institute codes and standards listed in the Project Manual except as modified therein or on the drawings. Maintain copy of each on job site during construction.
The minimum ultimate compressive strength of concrete at 28 days shall be:
5000 psi - Precast Stairs 4000 psi - All other unless noted otherwise on drawings.
Air Content: All concrete exposed to freezing and thawing and/or required to be watertight shall have an air content of 4.5% to 7.5%. All other concrete shall have an air content of 3% to 4%.
Water Cement Ratio: All concrete subjected to exposed to freezing and thawing in moist condition and/or required to be watertight shall have a maximum water-cement ratio of 0.45. All reinforced concrete exposed to deicing salts, brackish water seawater or spray from these sources, shall have a maximum water-cement ratio of 0.40.
Maximum aggregate size shall be 1 1/2 ", well graded, well-shaped (not elongated, flat, or slippery), and free of clay, dirt, and excess fines, U.N.O.
Aggregate composition shall consist of quartz, limestone, dolomite, granite, or feldspar.
Cement shall be Type 1, U.N.O.
Maximum concrete slump 3", U.N.O.
Reinforcing bars: ASTM A615, Grade 60.
Welded wire fabric: ASTM A185.
Provide 6x6-w2.9xw2.9 welded wire fabric in all non-structural slabs on grade, unless otherwise noted.
Place reinforcement in slabs, 1-1/2" down from top of slab, unless otherwise noted.
Provide control joints in all non-structural slabs on grade. The maximum spacing of control joints shall be 20'-0" O.C. unless otherwise noted.
Control joint depth equal to 1/5 slab thickness not less than 1 inch.
Reinforcing bar lap splices and anchorage lengths shall conform with ACI 318-11 "Development and Splices of Reinforcement." All splices shall be Type B.
Top layer of reinforcing steel in slabs and footings shall be considered top bars regardless of thickness of concrete below the bars.
All horizontal wall bars shall be bent lapped around all corners, unless otherwise noted.
Provide vertical and horizontal reinforcing bars in concrete walls to conform to the minimum provisions of ACI 318, Section 14.3 unless otherwise noted.
Chamfer exposed edges of concrete 1/2" unless otherwise noted.
Refer to architectural drawings for location and extent of finishes or other treatments to exposed concrete.
Determine size, location and weight of mechanical equipment and make provisions for bolts, sleeves, pads, etc. from manufacturer's certified drawings. This work shall be coordinated with the trades involved.
All new concrete shall be bonded to previously placed concrete per specification requirements, U.N.O.
The Contractor shall prepare shop drawings showing detail layouts of reinforcing, including dimensions, openings, and spacing, bending details, bar schedules, and similar items required for the proper construction of the work.Provisions for the connection of work by other trades shall be indicated on the shop drawings. The location of all embedded items shall be indicated by the contractor on the shop drawings. All shop drawings shall be submitted for approval in accordance with the requirements of the Contract Documents.
Preparing, curing, transporting, and testing concrete cylinders. For each class of concrete placed, at least four cylinders shall be taken for each 50 cubic yards, or fraction thereof, of each class of concrete placed each day. Cylinders are to be taken in accordance with ASTM C31 and results shall be submitted to the Architect/Engineer, Construction Manager and owner. Two cylinders will be tested at 7 days and two at 28 days.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
FOUNDATIONS:
Foundation design is based on an assumed allowable soil bearing capacity of 4,000 psf stated on the original drawings. Structural engineer is not responsible for subsurface conditions encountered in the field different from those assumed for design.
Foundations are indicated on the drawings as either drilled piers or spread footings, based on an interpretation of the existing drawings. After excavation to the bearing elevation and after evaluation of the bearing medium, it may be necessary to revise the foundation design from a drilled pier to a spread footing or from a spread footing to a drilled pier.
For spread footings where the soil or rock capable of supporting the minimum specified geotech report bearing capacity is below the bottom of the footing elevation, based on the top of footing elevation shown on the drawings, the top of the footing elevation shall be maintained, and a plain concrete pad, consisting of concrete with a 28-day compressive strength of 3000 PSI and utilizing type I cement, shall be placed under the footing. The plansize of the plain concrete pad shall be at least as large as the spread footing. Foundations for miscellaneous foundation walls, cantilevered retaining walls, and miscellaneous structures shall consist of individual and continuous spread footings and shall bear on soil capable of supporting 4000 PSF.
Notify the Architect of any unusual soil conditions that are in variance with the test borings, such as ground water, substandard bearing material, or obstructions.
Refer to Foundation Plan for footing elevations. Elevations shown are "top of concrete".
Backfilling against foundation or pit walls will not be permitted until supporting floors at the top of these walls are in place and able to provide full support to the imposed loads. Proper temporary bracing may be used in lieu thereof with prior approval of the Architect. The design of the temporary bracing is the responsibility of the General Contractor. G.C.'s Shoring Design Engineer shall provide a certified design for approval. Shoring forces will be provided by the E.O.R. upon request.
The General Contractor shall be responsible for the design, installation, and final clearance of any required shoring or bracing.
Remove all unsuitable fill and replace per the recommendations of the Geotechnical Engineer of record.
Anchor bolts shall be set in place prior to concrete placement.
They shall not be forced into wet concrete.
Unless noted otherwise in the geotechnical report or specifications, compact all fill under slabs on ground and foundations to 98% of optimum laboratory density in accordance with ASTM D698 Standard Proctor Method. Place fill in 6" to 8" lifts and compact with vibratory tamping equipment.
Locate existing underground utilities in areas of construction.
Contact local authorities for coordination.
When excavations approach the ground water level, the water level shall be continuously lowered by an acceptable dewatering system so that the water level is maintained continuously a minimum of 2'-0" below the excavation.
Shale containing pyrites must be protected as indicated in the Geotechnical Report.
1.
2.
a.
b.
c.
d.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
a.
b.
13.
14.
15.
16.
17.
18.
A.
B.
C.
D.
19.
20.
21.
22.
STRUCTURAL STEEL:
All structural steel work shall be in accordance with the "Specifications for the Design, Fabrication, and Erection of Structural Steel Buildings" (14th Edition) of the AISC. Maintain copy of each on job site during construction.
Structural steel shall conform to the following:
Wide flange shapes and WT's - ASTM A992 with a minimum yield strength of
50,000 PSI.
Channels, angles, plates, and miscellaneous connection material - ASTM A36 with a minimum yield strength of 36,000 PSI unless noted otherwise.
Pipes - ASTM A501 with a minimum yield strength of 36,000 PSI or ASTM A53 Type E or S with a minimum yield strength of 35,000 PSI.
Tubes - ASTM A500, Grade B with a minimum yield strength of 46,000 PSI.
All bolts shall be 3/4" dia. unless noted otherwise ASTM A325 H.S. bolt of either friction or bearing type. Use slip critical connections for all wind bracing connections. Threads shall be included in the shear plane.
All bolted connections shall be made according to AISC Table II or III framed beam connections. The minimum depth of connection must be more than one half the depth of the beam except that beams framing to columns shall have full depth connections using 3/8" connection angles or plates. Contractor shall provide certified design for all shear connections by a Professional Engineer in the state in which the project is located. Submit calculations for moment connections using braced member capacity U.N.O. on plans. Minimum end reaction of beams:
W8's = 10 kips W10's= 12 kips W12's= 16 kips W14's= 18 kips W16's= 20 kips W18's= 22 kips W21's= 24 kips W24's= 26 kips
All welding shall be in strict accordance with the standards of the AWS and the AISC. Use E70XX electrodes.
Contractor shall submit Welders' certificates in accordance with AWS B2.1/B2.1M.
It shall be dated no more than 12 months before start of scheduled welding work.
Do not paint steel where encased in concrete or at field weld areas.
No shop or field holes or cuts are to be placed in structural members unless indicated on the contract or shop drawings.
The Structural Steel Fabricator shall field verify all dimensions prior to fabrication.
Particularly for stairs, handrail systems, etc.
The Structural Steel Fabricator shall provide for vertical and horizontal adjustment of all support assemblies.
The Structural Steel Fabricator and/or the General Contractor shall verify all existing dimensions and conditions at the site. All discrepancies found shall be reported to the Architect prior to preparation of shop drawings. Shop drawings shall include all field measurements and conditions.
Expansion bolts:Use expansive anchors of the diameter indicated on the drawings as manufactured by HILTI Fastening Systems or approved equal.
In concrete, use HSL Heavy Duty Anchors.
In brick and CMU, use sleeve and fill CMU cells at all bolt locations.
Anchor bolts must meet ASTM A1554 gr. 36 specifications and be 3/4" diameter (unless otherwise indicated) .
The Structural Steel Fabricator shall provide all supports for any precast concrete panels as indicated on the drawings and as required by the manufacturer. Location of such supports shall be coordinated with the manufacturer.
The Structural Steel Fabricator, Precast Concrete Supplier, and the General Contractor shall coordinate all support and tie-back locations and connections, if applicable.
All galvanizing shall be per ASTM A123 and A780. All steel exposed to the elements and masonry support members shall be galvanized. Backup steel supporting masonry veneer and precast support angles shall be zinc primed and painted.
Refer to architectural and mechanical drawings for possible miscellaneous steel.
This steel shall also conform to the requirements in these General Notes and the Structural Steel specifications.
75% of field welds shall be visually inspected and tested using one of the following:
Radiographic testing performed in accordance with ASTM E94/E94M Ultrasonic testing performed in accordance with ASTM E164 Liquid penetrant inspection performed in accordance with ASTM E165/165M Magnetic particle inspection performed in accordance with ASTM E709
All shear studs shall be 3/4" diameter x 1 1/2" taller than the metal deck height.
(1 1/2" deck + 1 1/2" = 3")
Steel fabricator shall review Architectural drawings and include all miscellaneous steel in their bid. If notes on architectural drawings refer to "see structural" and the structural drawings do not address this item notify the E.O.R. at least two weeks prior to bid opening to allow time for issue of addendum.
Column Schedule may not include all columns on the project. Review all drawings to insure all columns are included in bid.
Steel lintels can be replaced with engineered reinforced precast lintels. Mfgr shall submit certified Engineer design with lintel submittal.
1.
2.
3.
DESIGN/CONSTRUCTION DOCUMENTS - EXISTING
CONSTRUCTION:
Design and construction documents are based upon assumptions made from available original and field investigation. Information shown may not necessarily reflect actual conditions. The contractor drawings shall field verify or establish the following:
All dimensions and elevations.
Existing conditions.
Existing structural arrangement and sizes in work areas.
The contractor shall notify the Architect of any discrepancies between the design documents and actual conditions. All existing dimensions and conditions shall be reflected on the shop drawings prior to submission for review.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
PERFORMANCE REQUIREMENTS:
No provision of any referenced standard specification, manual or code (whether or not specifically incorporated by reference in the contract documents) shall be effective to change the duties and responsibilities of owner, contractor, engineer, supplier, or any of their consultants, agents, or employees from those set forth in the contract documents.
Nor shall it be effective to assign to the structural engineer of record or any of the structural engineer of record's consultants, agents, or employees ant duty or authority to supervise or direct the furnishing or performance of the work or any duty or authority to undertake responsibilities contrary to the provisions or the contract documents.
Contract documents include, but are not limited to, the structural documents (drawings and specifications), but do not include shop drawing, vendor drawings, or materials prepared and submitted by the contractor.
Reference to standard specifications or any technical society, organization, or association or to codes of local or state authorities, shall mean the latest standard, code, specification or tentative specification adopted at the date of taking bids, unless specifically stated otherwise.
Contract documents shall govern in the event of a conflict with the code of practice or specifications of ACI, PCI, AISC, SJI, or other standards. Where a conflict occurs within the contract documents, the strictest requirement shall govern.
Contractor shall obtain and coordinate edge of slab and roof deck edge dimensions, opening locations and dimensions, depressed slab locations and extents, slab slopes, curb locations, and CMU wall location. Architect/Structural engineer shall be notified of any discrepancy or omission. In the event of discrepancies, the non-structural architectural details shall govern.
Contractor shall verify existing dimensions, elevations, and site conditions before starting work. Architect/Structural engineer shall be notified of any discrepancy.
Contractor shall verify the structurally supported mechanical equipment weights, opening sizes, and locations identified on the structural drawing with architectural and mechanical drawings.
Contractor shall verify that miscellaneous framing shown on the structural drawings for mechanical equipment, owner-furnished items, partitions, etc. is consistent with the requirements of such items.
Contractor has responsibility for means, methods, safety, techniques, sequences, and procedures of construction.
The structure is stable only in its completed form. Temporary supports required for stability during all intermediate stages of construction shall be designed, furnished, and installed by the contractor. Contractor is responsible for constructability analysis, and erection procedures, including design and erection of framework, temporary bracing, etc.
Contractor has sole responsibility to comply with all OSHA regulations.
Reproduction of structural drawings for shop drawings is not permitted.
Electronic drawing files will not be provided to the contractor.
Structural engineer of record is not responsible for the design of steel stairs, handrails, curtain wall/window systems, cold-formed metal framing, toilet partition supports, shelf systems, or other systems not shown in the structural documents, such systems shall be designed, furnished, and installed by others as required by other portions of the contract documents.
Structural Engineer shall not be responsible for specifying all waterproofing details and elements on the superstructure and below grade structures.
General Contractor shall review and coordinate elevator rail and hoist requirements with structural drawings. Notify structural engineer immediately if changes are required.
1.
2.
3.
4.
5.
6.
PRECAST WALL PANELS AND STAIR AND ELEVATOR SHAFTS:
Precast wall panels shall be designed to support the live and dead loads noted above for the tributary areas which are supported by the panel, plus any concentrated live and dead loads from steel framing as indicated on the structural details, at the eccentricities indicated, plus wind loading per the IBC 2018 where applicable.
Tributary areas in plan noted as stairways shall be assumed to have a 100 PSF live load and dead load is determined by the stair manufacturer.
Refer to the architectural drawings for information regarding the sizes of wall panels, spacing, heights, joints, opening sizes and locations, and details. Where joints are not specifically located in plan or section, precast contractor may locate joints as required subject to the review of the Architect.
All precast wall panels shall be assumed to be 8" minimum thickness, unless noted otherwise on the structural drawings. At the fabricator's option, heavily loaded wall panels may be increased in thickness up to a maximum of 12" thickness. In this event, the Architect and engineer will be advised of the submission of bid and the change in size will be noted in writing at the same time of the bid submission. The Architect shall determine the final location of panels with increased thickness. The precast contractor shall be responsible for incorporating all framing and detailing modifications required by this change into the work.
Provide factory installed inserts or field drilled inserts for the support of window or door frames, metal grating, mechanical equipment, piping, conduit, etc. as required on the architectural and mechanical drawings. The architect has the right to reject the relocation of anchors which will be exposed to view.
Provide anchor bolts, dowels, beam pockets, anchor plates, anchor inserts, etc. as required for the support and operation of electrical and mechanical equipment, elevator separator beams and other structural items, precast or steel fire stairs, and light fixtures. Refer to the mechanical and electrical drawings for additional information. Show all placement on shop drawings.
Provide connections between adjacent precast panels at vertical joints, minimum two per panel joint, but as required by analysis for stability. Connections shall consist of factory cast anchor plates with anchor bolts to be connected by steel bars or angles bolted in place after erection. Provide adequate erection and alignment tolerance. Provide recessed connection and fill with non-shrink grout as required by Architect for finish appearance.
Tension lap spice lengths, (bar diameters, db) for grade 60 uncoated bars; normal-weight concrete
Lap Length per Spacing and Cover Case
2 3 1 2 3
#7-#11
#3-#6
B 85db
66db
68db
54db
91db
70db
74db
56db
99db
76db
80db
62db
108db
83db
86db
68db
121db
93db
98db
74db
139db
107db
112db
86db
57db
44db
46db
36db
61db
47db
50db
38db
66db
51db
54db
42db
72db
56db
58db
46db
81db
62db
66db
50db
93db
72db
74db
58db
34db
27db
28db
22db
37db
28db
30db
23db
40db
31db
32db
26db
43db
34db
42db
32db
49db
37db
40db
30db
56db
43db
46db
36db
66db
51db
54db
42db
70db
54db
56db
44db
76db
59db
62db
48db
83db
64db
68db
52db
93db
72db
74db
58db
107db
83db
86db
66db
44db
34db
36db
28db
47db
36db
38db
30db
51db
39db
42db
32db
56db
43db
46db
34db
62db
48db
50db 38db
72db
55db
58db
44db
27db
21db
22db
18db
28db
22db
23db
18db
31db
24db
26db
19db
34db
26db
27db
21db
37db
29db
31db
24db
43db
33db
36db
28db
A
B
A f'c (psi)
Bar Size
Lap Class
1.
2.
3.
4.
5.
6.
7.
8.
9.
Lap Notes:
Lap splice lengths are based on ACI318-08 section 12.2 and subsections 12.2.2 and 12.2.3.
Category definitions: (see figures below for additional information).
Category 1 - Code 12.2.2 other cases - does not meet category 2 or 3.
Category 2 - Code 12.2.2 - clear spacing of bars being developed or spliced not less than 2db and clear cover not less than db.
Category 3 - Code 12.2.3 - clear cover not less than 2db and clear spacing not less than 4db.
Minimum lap splice shall not be less than 12 inches.
Multiply above lengths by 1.25 for grade 75 reinforcing steel.
Top bars are defined as horizontal reinforcement so placed that more than 12 inches of fresh concrete is cast in the member below the development length or splice.
Compression laps for GR. 60 uncoated bars in normal weight concrete with a minimum strength of 3000 psi shall be 30 db. Use 44 db for GR. 75 compression lap.
For epoxy-coated bars or wires with cover less than 3db, or clear spacing less than 6db, multiply lap length by 1.5. For all other epoxy coated bars or wires, multiply lap length by 1.2.
For lightweight concrete multiply lap length by 1.3.
Lap Class is determined in accordance with ACI318-08 section 12.15.2, use class B U.N.O.
Category 2 Face of concrete
Clear spacing at staggered splices
Clear Spacing, X
Category 3 Face of concrete
Clear spacing at offset column bars
Offset bars from column below Bars in column above
REINFORCING LAP LENGTH SCHEDULE
#7-#11
#3-#6
B
A
B A
#7-#11
#3-#6
B
A
B
A
#7-#11
#3-#6
B
A
B
A
#7-#11
#3-#6
B
A
B
A
#7-#11
#3-#6
B
A
B
A
Top Horizontal Bars
Category
All Other Bars
Category
7 8
>=4db
Clear Spacing, X
2d b
>=2db db
1.
2.
3.
4.
5.
6.
7.
SHOP DRAWINGS:
See Project Manual - Administrative Requirements for submittal procedures.
The General Contractor shall review, check, and stamp "Approved" all shop drawings prior to submitting them to the Architect. Shop drawings which have not been stamped "Approved" by the General Contractor do not conform to the requirements of the Contract Documents and will be rejected.
The General Contractor shall provide a shop drawing submittal schedule to the Architect at least two weeks prior to submittal of the first set of shop drawings.
Shop drawing submittals and review must precede the start of fabrication.
General Contractor proceeds at their own risk without reviewed as noted shop drawings from the Architect. The maximum turn-around time for shop drawings will be two weeks (ten working days) from the date of receipt in the Architect's office to the date of return delivery. General Contractor and Architect shall increase coordination efforts when large numbers of shop drawings are invited.
Refer to the Project Manual (if available) for specific submittal procedures.
Shop drawings shall not simply be a copy of the engineer's design drawings with the contractor's title block. Electronic files from the E.O.R. can be provided to the G.C. at a negotiated fee. Fee will be based on amount of subcontractor's contract and benefit to subcontractor.
Shop drawings shall be completely prepared by the submitting entity.
1.
STRUCTURAL STEEL WELDING
All welding shall be in strict conformance with latest building code and AWS D1.1
1.
2.
3.
4.
5.
CONSTRUCTION MEANS AND METHODS
Contractor agrees that Contractor shall assume sole and complete responsibility for job site conditions during the course of the Work, including safely of all persons and property; that this requirement shall apply continuously and not be limited to normal working hours; and that Contractor shall defend, indemnify, and hold Owner and Structural Engineer harmless from any and all liability, real or alleged, in connection with the performance of the Work on this Project, excepting for liability arising from the sole negligence of Owner or Structural Engineer.
The Contract Documents represent the finished structure. They do not include the method of construction. Contractor shall provide all measures necessary to protect the structure during construction. Such measures shall include, but not be limited to:
protection of subgrade from freezing conditions, bracing, shoring for loads due to construction equipment, temporary structures, and partially completed work. Observation visits to the site by Structural Engineer shall not include inspection of the above items.
ADS Consulting Engineers shall not have control over or charge of and shall not be responsible in any way for construction means, methods, techniques, sequences, or procedures, or safety or safety precautions and programs in connection with any construction activities, since these are solely Contractor’s responsibility under the Contract.
ADS Consulting Engineers shall not be responsible for Contractor’s schedule or failures to carry out any construction activities in accordance with the Contract Documents. ADS Consulting Engineers shall not have control over or charge of actions of Contractor, Subcontractor, or any of their Agents, or employees, or any other persons performing portions of any construction activities.
The structure is stable only in its completed form. Temporary supports required for stability of the structure during all intermediate stages of construction shall be designed and provided by Contractor.
STRUCTURAL ABBREVIATION LISTING
DEFINITIONABBREVIATION
QTY.
U.N.O.
QUANTITY
UNLESS NOTED OTHERWISE
DEFINITIONABBREVIATION
L
DEFINITIONABBREVIATION DEFINITIONABBREVIATION
VERTICAL
VERTICAL EACH FACE
VERTICAL INSIDE FACE/
VERTICAL OUTSIDE FACE
TOP AND BOTTOM
TOP OF
THICK(NESS)
THICKENED
TRANSVERSE
TYPICAL
T&B T/
THK.
THK'ND.
TRANS.
TYP.
HOOK
HORIZONTAL OUTSIDE FACE
HORIZONTAL INSIDE FACE
HORIZONTAL
HIGH POINT
HEIGHT
HORIZONTAL EACH FACE
C/C
CAIS.
CANT'LR.
C.G.
C.I.P.
C.J.
C/CL.
CLG.
CLR.
C.M.U.
COL.
COMP.
CONC.
CONN.
CONSTR.
CONT.
CONTR.
COORD.
CTR.
WITH
WITHOUT
WIND LOAD
WORK POINT
WEIGHT
WELDED WIRE FABRIC
SCHEDULE
SECTION
SHEET
SIMILAR
SHORT LEG VERTICAL
SHORT LEG HORIZONTAL
SLAB ON GRADE
SPACE(S)(ING)
SPECIFICATION
SQUARE
SQUARE FEET
SQUARE INCH
STANDARD
STIFFENER
STEEL
STRUCTURAL
SYMMETRICAL
RADIUS
REFERENCE
REINFORCED
REQUIRED.
REVISION
PRECAST CONCRETE
PERIMETER
PLATE
PROJECTION
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
POINT
POST-TENSION(ED)(ING)
POURED IN PLACE
ON CENTER
OUTSIDE FACE
OPENING
OPPOSITE
OPPOSITE HAND
NOT IN CONTRACT
NEAR SIDE
NOT TO SCALE
NUMBER
MASONRY
MATERIAL.
MAXIMUM
MECHANICAL
METAL
MEZZANINE
MANUFACTURER
MINIMUM
MISCELLANEOUS
MARK
MASONRY OPENING
LENGTH
POUND
LEVELLING PLATE
LONG
LIVE LOAD
LONG LEG HORIZONTAL
LONG LEG VERTICAL
LONGITUDINAL
KIP
KIP FEET
KIPS PER LINEAR FOOT
KNOCKOUT
KIPS PER SQUARE FOOT
KIPS PER SQUARE INCH
JOIST
JOINT
INSIDE FACE
INCH(ES)
INTERIOR
GAGE
GALVANIZED
GENERAL
GRADE
GRATING
FOUNDATION
FINISH FLOOR
FINISH FLOOR ELEVATION
FINISH
FLOOR
FULL PENETRATION
FOOTING STEP
FOOT
FOOTING
EACH
EACH END
EACH FACE
ELEVATION
ELEVATOR
EDGE OF SLAB
EQUAL
EQUALLY SPACED
EQUIPMENT
EACH SIDE
EACH WAY
EACH WAY BOTTOM
EACH WAY TOP
EXISTING
EXPANSION
EXPANSION JOINT
EXTERIOR
DEGREE
DETAIL
DIAMETER
DIAGONAL
DIMENSION
DECK
DEAD LOAD
DOWN
DRAWING
DOWEL
CENTER TO CENTER
CAISSON
CANTILEVER
CENTER OF GRAVITY
CAST IN PLACE
CONTROL JOINT
CENTERLINE
CEILING.
CLEAR(ANCE)
CONCRETE MASONRY UNITS
COLUMN
COMPOSITE
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
COORDINATE
CENTER
BUILDING
BEAM
BOTTOM
BASE PLATE
BRIDGING
BEARING
BEARING PLATE
BASEMENT
BENT
AND
AT
ANCHOR BOLT
ADJACENT
ALTERNATE
APPROXIMATE
ARCHITECTURAL
ARCHITECT
W/ W/O W.L.
W.P.
WT.
W.W.F.
V/VERT.
V.E.F.
V.I.F.
V.O.F.
SCHED.
SECT.
SHT.
SIM.
SLV.
SLH
S.O.G.
SPA.
SPEC.
SQ.
SQ. FT.
SQ. IN.
STD.
STIFF.
STL.
STRUCT.
SYM.
R/RAD.
REF.
REINF.
REQ'D.
REV.
P.C.
PERIM.
PL.
PROJ.
PSF
PSI
PT.
P'TEN.
P.I.P.
O.C.
O.F.
OPNG.
OPP.
OPP. HAND
N.I.C.
N.S.
N.T.S.
NO./#
MAS.
MAT'L.
MAX.
MECH.
MET.
MEZZ.
MFR.
MIN.
MISC.
MK.
M.O.
L.
LB.
LEV. PL.
LG.
L.L.
LLH
LLV
LONG.
K
K. FT.
KLF
K.O.
KSF
KSI
JST.
JT.
I.F.
IN.
INT.
HK.
H.O.F.
H.I.F.
HORIZ.
H.P.
HT.
H.E.F.
GA.
GALV.
GEN.
GR.
GRTG.
EA.
E.E.
E.F./EA. FACE
EL.
ELEV.
E.O.S.
EQ.
EQ. SPA.
EQUIP.
E.S.
E.W.
E.W.B.
E.W.T.
EXIST.
EXP.
E.J./EXP. JT.
EXT.
FDN.
F.F.
F.F.E.
FIN.
FL.
F.P.
F.S.
FT.
FTG.
DEG.
DET.
DIA.
DIAG.
DIM.
DK.
D.L.
DN.
DWG.
DWL.
BLDG.
BM.
B/ OR BOT.
B. PL.
BRDG.
BRG.
BRG. PL.
BSMT.
BT.
A.B.
ADJ.
ALT.
APPROX.
ARCH.
ARCH'T.
VERIFY IN FIELD
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/4 /2 :0 :4
P M
S001
Blackwater Falls Lodge Exterior Stair Repair/
Replacement
JDR
12.4.2024
GENERAL NOTES
BRH
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
DRAWING LIST
DRAWING
NUMBER DRAWING NAME
S001 GENERAL NOTES
S100 NORTH STAIR PLAN
12-4-2024
S
DD
FF
S100
PR
EC
AS
T
ST
AI
R B
Y O
TH
ER
S
10"
CONCRETE
EXST WALL FOOTING
8' - 8"
42" CONCRETE
(3) LAYERS #4 @ 8" O.C. E.W.
3'
0"
4' - 4 1/2"
V.
I.F
8'
1/
2" 3'
0"
V.
I.F
0'
DD
FF
S100
EXST 18 WF 64#
EXST COLUMN
PR
EC
AS
T
ST
AI
R B
Y O
TH
ER
S
S100
PR
EC
AS
T
ST
AI
R B
Y O
TH
ER
S
S100
CONTINUOUS CANTILEVERV.I.F.
PR
EC
AS
T
M
FG
R
LO
C
AT
E
PE
R
5/16"
TYP. BOTH
PLATES-
LENGTH OF
CANTILEVER
EXST 18 WF 64# BEAM-
ASSUMED A7 STEEL.
CONTRACTOR TO VERIFY
WELDABILITY OF STEEL
1/2" A36 STEEL PLATES -
FULL LENGTH OF
CANTILEVER PORTION
L4X3X3/8 LLH ANGLE W/ 3/8" STIFFENER @ 24" O.C.
FULL LENGTH OF CANTILEVER BEAM
1/4"
L3X3X3/8 TO SUPPORT PRECAST
LEVEL 1
0' - 0"
LEVEL 2
13' - 0"
DF
V.I.F.
24' - 1 1/2"
V.
I.F
4'
5"
EXST 8" FOUNDATION.
DRILL AND EPOXY VERT. DOWELS INTO FNDN W/
HILTI HIT-HY 200 EPOXY W/ 5" EMBED.
PRECAST STAIRS AND HANDRAIL DESIGNED BY OTHERS
CW10
S100
42" CONCRETE FOUNDATION
EXST 18 WF 64#
V.I.F.
12' - 7" 3' - 0"
RAILING DESIGNED BY OTHERS
*ALL DIMENSIONS SHALL BE VERIFIED IN FIELD*
EXST STRUCTURE
LEVEL 2
13' - 0"
D
PRECAST LANDING BY OTHERS
S100
TYP.
EXST 18 WF 64#
PRECAST MFGR SHALL
PROVIDE CONTINUOUS
LANDING OVER BEAM
0'
3"
RAILING BY OTHERS
CW10
PRECAST STAIRS
BY OTHERS
3/4" A36 THREADED ROD DOWEL - 6" EMBED
INTO CONCRETE WALL. CONNECTION TO
PRECAST BY PRECAST ENGR.
(2) DOWELS PER PRECAST SECTION
SHIM AS REQUIRED
T/PIER = 5' - 4"
WALL REINF.
NOT SHOWN
FOR CLARITY
LEVEL 2
13' - 0"
D
EXST 18 WF 64#
EXST PIPE COLUMN
IF NOT EXST, ADD 3/8" A36
STIFFENER BOTH SIDES OF
BEAM OVER COLUMN.
1/4"
TYP. BOTH
SIDES
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/4 /2 :0 :4
P M
S100
Blackwater Falls Lodge Exterior Stair Repair/
Replacement
JDR
12.4.2024
NORTH STAIR PLAN
BRH
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
1.
2.
3.
4.
5.
6.
NOTES:
ELEVATIONS REFERENCE FINISH FLOOR. REFERENCE LEVEL = 0'-0" (LEVEL 1 )
FOUNDATION DESIGN BASED ON BEARING CAPACITY OF 4,000 PSF PER THE ORIGINAL DRAWINGS.
ALL ELEVATIONS TO EXST ELEMENTS MUST BE V.I.F.
PRECAST STAIRS AND HANDRAIL SHALL BE DESIGNED BY OTHERS. REFER TO GENERAL NOTES FOR REQUIRED LOADING.
PRECAST MANUFACTURER SHALL ACCOUNT HANDRAIL POST EMBEDS IN THEIR DESIGN.
ALL DIMENSIONS SHALL BE VERIFIED IN FIELD.
PLAN
NORTH
SCALE: 1/4" = 1'-0"
LEVEL 1 PLAN
PLAN
NORTH
SCALE: 1/4" = 1'-0"
LEVEL 2 PLAN
SCALE: 1 1/2" = 1'-0"S100
3 18 WF 64# PLATE REINFORCING DETAIL
SCALE: 1/4" = 1'-0"S100
4 NORTH STAIR SECTION
SCALE: 3/4" = 1'-0"S100
5 LEVEL 2 STAIR LANDING SUPPORT DETAIL
SCALE: 3/4" = 1'-0"S100
PRECAST LANDING TO CONCRETE WALL ATTACHMENT
DETAIL
CONCRETE WALL SCHEDULE
Type Mark WALL TYPE HORIZ. BAR VERT. BAR
CW10 10" CONCRETE #6 @ 18" O.C. #6 @ 18" O.C.
PRECAST LANDING SHALL
BEAR ON TOP OF ANGLE.
CONNECTION PER
PRECAST ENGR.
SCALE: 3/4" = 1'-0"S100
7 EXST BEAM OVER COLUMN SECTION
12-4-2024
& and angle
@ at C centerline channel ° degrees diameter or round perpendicular
P plate ± plus or minus # pound or number
ABBREVIATIONS
E. east E.C. electric contractor E.J. expansion joint E.W.C. electric water cooler EA. each ELAS. elastometric ELEC. electric (al) ELEC. CAB. electric cabinet ELEV. elevator, elevation EMER. emergency ENCL. enclose (ure) ENTR. entrance EQ. equal EQUIP. equipment ESTB. establish EXP. expansion EXSTG. existing EXT. exterior
F.B.O. furnished by others F.D. floor drain F.E. fire extinguisher F.E.C. fire extinguisher cab.
F.H.C. fire hose cabinet F.O.C. face of concrete F.O.F. face of finish F.O.S. face of studs F.S. full size F.T.F. face to face FDN. foundation FIN. finish (ed) FL. floor (ing) FLASH’G. flashing FLUOR. fluorescent FRPF. fireproof (ing) F.P.W.H. freeze proof wall hydrant FT. foot or feet FTG. footing FURN. furnish FURR. furring FUT. future F.V. field verify
JAN. janitor JT. joint
K.D. kiln dried or knock down
KIT. kitchen KO. knockout
L. left, length L.H. left hand L.L. live load L.P. low point L.R. living room L.W. lightweight LAB. laboratory LAM. laminate (d) LAV. lavatory LT. light LTG. lighting LVR. louver
M. men M.C. medicine cabinet or mechanical contractor M.H. manhole M.O. masonry opening MACH. machine MAINT. maintenance MAS. masonry MATL. material (s) MAX. maximum MBR. member MECH. mechanic (al) MED. medium MEMB. membrane MTL. metal M.T. metal threshold MEZZ. mezzanine MFR. manufacture (er) MIN. minimum MISC. miscellaneous MOD. modified MRGWB. moisture resistant gypsum wall board MTD. mounted MUL. mullion
R. riser, radius R.A. return air R.C.P. reinforced concrete pipe R.D. roof drain R.H. right hand R.O. rough opening R.O.W. right of way REBAR. reinforcing bar REC. recessed RECT. rectangular REF. reference or refrigerator REG. register REINF. reinforced REQ. required RESIL. resilient RET. return REV. revision(s), revised RFG. roofing RL. roof leader RM. room
STL. steel STOR. storage STRUC. structure (al) SURF. surface SUSP. suspended SW. switch SYM. symmetry (ical)
T&B. top and bottom T&G. tongue and groove tread T.C. top of curb T.P. top of pavement T.P.D. toilet paper dispenser T.W. top of wall TEL. telephone TEMP. tempered or temperature TERZ. terrazzo THK. thick (ness) THRES. threshold TLT. toilet T.O.S. top of steel TV. television TYP. typical
L
L
W. west, women W.C. water closet W.F. wide flange W.I. wrought iron W.W.F. welded wire fabric W/ with W/O without WD. wood WDW. window WP. waterproofing WSCT. wainscot WT. weight
YD. yard
CAB. cabinet CARP. carpet CEM. cement CER. ceramic CLG. ceiling CLO. closet CLR. clear CNTR. counter COL. column COMP. composition CONC. concrete CONF. conference CONN. connection CONSTR. construction CONT. continuous CONTR. contractor CORR. corridor CSMT. casement CTR. center CTSK. countersink
(sunk)
A.B. anchor bolt A.F.F. above finish floor A.P. access panel A.T.C. acoustical tile ceiling A/C. air conditioning ABV. above ACC. accessible ACOUS. acoustical ADD. addendum ADJ. adjacent or adjustable AGG. aggregate AL. aluminum ALT. alternate ANOD. anodize APPROX. approximate APT. apartment ARCHT. architect (ural) AUTO. automatic AVG. average
S-P. single-ply S. south S.C. solid core S.C.J. structural control joint S.D. soap dispenser or storm drain S.F. square foot S.N.D. sanitary napkin dispenser S.N.R. sanitary napkin receptacle S.S. stainless steel S.T.C. sound transmission classification S4S. surfaced 4 sides SAN. sanitary SCHED. schedule SECT. section SFTWD. softwood SHT. sheet SIM. similar SPEC. specification SQ. square SQ. FT. square foot STD. standard
B.U.R. built-up roofing BD. board BEV. beveled BITUM. bituminous BLDG. building BLK. block BLKG. blocking BM. beam or bench mark BR. bedroom BRCG. bracing BRG. bearing BSMT. basement BTW. between
C.B. catch basin C.H. ceiling height C.I. cast iron C.J. control joint or construction joint C.M.T. ceramic mosaic tile C.M.U. concrete masonry unit C.T. ceramic tile C. to C. center to center
D. diameter D.F. drinking fountain D.H. double hung D.L. dead load DBL. double DEM. demolish, demolition DEPT. department DIAG. diagonal, diagram DIFF. diffuser DIM. dimension DISP. dispenser DMT. demountable DN. down DO. door opening DR. door DS. downspout DTL. detail DWG. drawing DWR. drawer
G.B. grab bar G.C. general contractor G.S.F. gross square feet GA. gage, gauge GALV. galvanized GL. glass, glazing GR. grade GWB gypsum wall board
H.B. hose bibb H.C. hollow core H.M. hollow metal H.P. horsepower HDW. hardware HDWD. hardwood HORIZ. horizontal HT. height HVAC. heating/ventilating/air conditioning HWY. highway
N. north N.I.C. not in contract N.T.S. not to scale NO. or # number NOM. nominal
O. to O. out to out O.C. on center (s) O.D. outside diameter OFCI owner furnish, contractor install OFF. office O.H. opposite hand OPN’G. opening OPP. opposite OUT. culvert OZ. ounce
Q.T. quarry tile
U.C. undercounter U.O.N. unless otherwise noted UNFIN. unfinished UTIL. utility
V.B. vinyl base V.C.T. vinyl composition tile V.I.F. verify in field V.F. vinyl fabric V.T. vinyl tile V.W.F. vinyl wall fabric VENT. ventilating VERT. vertical VEST. vestibule VLY. valley VOL. volume
PLYWOOD
MATERIAL DESIGNATIONS
FINISHED WOOD
WOOD FRAMING
WOOD BLOCKING
BATT INSULATION
RIGID INSULATION
EARTH
GRAVEL
CONCRETE
PLASTER, SAND, GROUT, GWB
BRICK
CMU
DOOR NUMBER WINDOW TYPE
SYMBOL-REVISIONS
REVISED AREA
REVISION NUMBER
? DIMENSION TYPES
5'-0"
R 3' -0"
SYMBOL-FINISHED FLOOR ELEVATION
ROOM IDENTIFICATION
ROOM NUMBER
SYMBOL-DETAIL CALLOUT
REFER TO THIS
DRAWING ID
EXTERIOR
ELEVATION
INTERIOR
ELEVATION
REFER TO THIS
DRAWING ID
SYMBOL-BUILDING SECTION / WALL SECTION
REFER TO
DRAWING ID
A8.01
1B
7B 3B
5B
COLUMN
CENTER LINE
COLUMN GRID
NUMBER
A5.02
1H
A8.00 3D
INTERIOR
ELEVATION
SYMBOL-EXTERIOR ELEVATION / INTERIOR ELEVATION
SYMBOL-ROOM TAG
ROOM AREA
SYMBOL-COLUMN GRID
SYMBOL-WALL / DOOR / WINDOW
WALL TYPE
SYMBOL-SPOT ELEVATION
SYMBOL-VIEW LABEL
SYMBOL-PROPERTY LINE TAG
SYMBOL-FIXTURE / FURNITURE / EQUIPMENT
TAG
SYMBOL-STAIR TAG
SYMBOL-CEILING TAG
CENTER LINE
LINEAR
DIMENSION
TYPE
ANGULAR
DIMENSION TYPE
RADIAL
DIMENSION TYPE
METAL
A1.01
SIM.
Name Elevation
1H View Name 1/8" = 1' - 0"
20R @ 7"
9' - 0" A.F.F.
N 90 00' 00" E Distance
A A.1
A1.01
SIM.
A1.01
SIM.
GENERAL NOTES:
1. UNLESS NOTED OTHERWISE, DIMENSIONS ARE TAKEN FROM FACE OF MASONRY AND
CONCRETE WALLS AND FACE OF EXISTING WALLS.
2. NEW WORK EXTENDING EXISTING CONDITIONS SHALL ALIGN WITH AND MATCH
EXISTING WORK EXCEPT WHERE OTHERWISE DIMENSIONED OR DETAILED.
3. THE CONTRACTOR WHOSE WORK REQUIRES THE CUTTING OF EXISTING
CONSTRUCTION AND FINISHES SHALL BE RESPONSIBLE FOR THE REPAIR OF SUCH
CONSTRUCTION AND FINISHES. THE REPAIR SHALL BE PERFORMED BY TRADES PEOPLE
WHO ARE BY TRAINING AND EXPERIENCE QUALIFIED TO MAKE SUCH REPAIRS.
4. ALL PENETRATIONS THROUGH FLOOR SLABS AND WALLS, SUCH AS PIPING,
CONDUITS, DUCTS, PNEUMATIC TUBES, ETC., SHALL BE PACKED AND SEALED OFF WITH
FIRE RATED MATERIAL (WHERE APPLICABLE) AND SEALED AGAINST WATER
PENETRATION.
5. SHOULD THE CONTRACTOR ENCOUNTER ANY MATERIAL IDENTIFIED AS ASBESTOS,
OR SUSPECTED OF CONTAINING ASBESTOS FIBERS, HE SHALL IMMEDIATELY REPORT
TO OWNER FOR INSTRUCTIONS.
6. ALL ELECTRICAL, MECHANICAL, & PLUMBING WORK IS TO BE PERFORMED BY A
LICENSED CONTRACTOR IN SAID FIELD.
RA
DE
CTI E TET RS
ER
C G I
H
FO
ATS
ET GINI
VIR
TSWE
PAUL A.
2626NO.
WALKER A
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/2 /2
:3
:2
P M
A0.00
Blackwater Falls Lodge
Exterior Stair Repair/
Replacement
PAW
12.4.2024
Abbreviations, General Notes, Details
AEW
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
1" = 1'-0" 3A Abbreviations
A
REF.
UP
UP
UP
UP UP
7 7.5 9 10
12 13
14 15 16
A A
B B
C C
E
F F
6.5 8
D
5' - 9"
A2.00 10H
A2.01
10HSOUTH STAIR AREA OF WORK NORTH STAIR AREA OF WORK
RA
DE
CTI E TET RS
ER
C G I
H
FO
ATS
ET GINI
VIR
TSWE
PAUL A.
2626NO.
WALKER A
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/2 /2
:3
:2
P M
A1.00
Blackwater Falls Lodge
Exterior Stair Repair/
Replacement
PAW
12.4.2024
Area of Work Plan
AEW
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
3/32" = 1'-0" 1H Area of Work Plan
N
PLAN
NORTH
UPDN
UPDN
E
F
A2.00 1H
4' - 11"
4'
" 4' - 7" 5' - 5"
SOUTH STAIR (POOL)
CLEAR
4' - 4"
T
1" E
A
4'
1.
2.
3.
4.
DEMOLITION:
COMPLETELY REMOVE PAINT, RUST, & LIME/CALCIUM
DEPOSITS TO A SOUND SUBSTRATE ON STAIR STRINGERS,
RISERS, RAILS, SUPPORT COLUMNS & BASE PLATES, ALL
SIDES.
METHOD FOR PAINT REMOVAL TO BE MECHANICAL (NOT
CHEMICAL) PER CONTRACTOR's CHOICE.
STAIR TREAD SURFACE COATING IS NOT TO BE DAMAGED
OR IT SHALL BE COMPLETELY & PROPERLY REMOVED, RE-
APPLIED, & WARRANTED AT CONTRACTOR'S EXPENSE.
WORK SHALL BE SCHEDULED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
E
F
A2.00 1H
4'
SOUTH STAIR (POOL)
9' - 7 1/2" 3"
7'
1/
2"
4' - 10"
CLEAR
4' - 4"
CLEAR
4' - 4"
1.
2.
3.
4.
DEMOLITION:
COMPLETELY REMOVE PAINT, RUST, & LIME/CALCIUM
DEPOSITS TO A SOUND SUBSTRATE ON STAIR STRINGERS,
RISERS, RAILS, SUPPORT COLUMNS & BASE PLATES, ALL
SIDES.
METHOD FOR PAINT REMOVAL TO BE MECHANICAL (NOT
CHEMICAL) PER CONTRACTOR's CHOICE.
STAIR TREAD SURFACE COATING IS NOT TO BE DAMAGED
OR IT SHALL BE COMPLETELY & PROPERLY REMOVED, RE-
APPLIED, & WARRANTED AT CONTRACTOR'S EXPENSE.
WORK SHALL BE SCHEDULED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
Level 1 0"
Roof 21' - 2 3/4"
Level 2 13' - 0"
E FD
7' - 3 1/2" 11T @ 11" EA = 10' - 1" 4' - 10"
4' - 11"
SOUTH STAIR (POOL)
R
-1 /2
" E A
6'
6"
R
-1 /2
" E A
6'
6"
1.
2.
3.
4.
5.
NEW WORK:
PRIME & PAINT ALL PREPARED METAL SURFACES
INCLUDING HAND & GUARDRAILS, STAIR STRINGERS &
RISERS, SUPPORT POSTS, BRACING, & ANCHOR PLATES.
APPLY PRIMER APPROPRIATELY FORMULATED FOR
SUBSTRATE.
APPLY MINIMUM TWO (2) COATS OF SEMI-GLOSS
EXTERIOR PAINT TO MATCH EXISTING LODGE.
PROTECT SURROUNDING HORIZ. & VERT. SURFACES
FROM PAINT SPLATTER.
WORK SHALL BE PLANNED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
1.
2.
3.
4.
DEMOLITION:
COMPLETELY REMOVE PAINT, RUST, & LIME/CALCIUM
DEPOSITS TO A SOUND SUBSTRATE ON STAIR STRINGERS,
RISERS, RAILS, SUPPORT COLUMNS & BASE PLATES, ALL
SIDES.
METHOD FOR PAINT REMOVAL TO BE MECHANICAL (NOT
CHEMICAL) PER CONTRACTOR's CHOICE.
STAIR TREAD SURFACE COATING IS NOT TO BE DAMAGED
OR IT SHALL BE COMPLETELY & PROPERLY REMOVED, RE-
APPLIED, & WARRANTED AT CONTRACTOR'S EXPENSE.
WORK SHALL BE SCHEDULED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
E
F
A2.00 1H
4' - 11"
4'
" 4' - 7" 5' - 5"
SOUTH STAIR (POOL)
CLEAR
4' - 4"
T
1" E
A
4'
1.
2.
3.
4.
5.
NEW WORK:
PRIME & PAINT ALL PREPARED METAL SURFACES
INCLUDING HAND & GUARDRAILS, STAIR STRINGERS &
RISERS, SUPPORT POSTS, BRACING, & ANCHOR PLATES.
APPLY PRIMER APPROPRIATELY FORMULATED FOR
SUBSTRATE.
APPLY MINIMUM TWO (2) COATS OF SEMI-GLOSS
EXTERIOR PAINT TO MATCH EXISTING LODGE.
PROTECT SURROUNDING HORIZ. & VERT. SURFACES
FROM PAINT SPLATTER.
WORK SHALL BE PLANNED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
E
F
A2.00 1H
4'
SOUTH STAIR (POOL)
9' - 7 1/2" 3"
7'
1/
2"
4' - 10"
CLEAR
4' - 4"
CLEAR
4' - 4"
1.
2.
3.
4.
5.
NEW WORK:
PRIME & PAINT ALL PREPARED METAL SURFACES
INCLUDING HAND & GUARDRAILS, STAIR STRINGERS &
RISERS, SUPPORT POSTS, BRACING, & ANCHOR PLATES.
APPLY PRIMER APPROPRIATELY FORMULATED FOR
SUBSTRATE.
APPLY MINIMUM TWO (2) COATS OF SEMI-GLOSS
EXTERIOR PAINT TO MATCH EXISTING LODGE.
PROTECT SURROUNDING HORIZ. & VERT. SURFACES
FROM PAINT SPLATTER.
WORK SHALL BE PLANNED TO MINIMIZE IMPACT ON
LODGE OPERATIONS.
1/4" = 1'-0" 1H South End Stair 1
RA
DE
CTI E TET RS
ER
C G I
H
FO
ATS
ET GINI
VIR
TSWE
PAUL A.
2626NO.
WALKER A
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/2 /2
:3
:2
P M
A2.00
Blackwater Falls Lodge
Exterior Stair Repair/
Replacement
PAW
12.4.2024
South Stair
AEW
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
N
PLAN
NORTH 1/4" = 1'-0"
10H Demo-Enlarged South Stair - Level 1 1/4" = 1'-0"
7H Demo-Enlarged South Stair - Level 2
1/4" = 1'-0" 10D Enlarged South Stair - Level 1
1/4" = 1'-0" 7D Enlarged South Stair - Level 2
UP
R
EF
DN
UP
UP
R
EF
DN
DN
F
D
A2.011H
NORTH END STAIR (KITCHEN)
1/
2" 1'
6"
/8
4' - 3" 3" 4' - 3"
5' - 0" 3' - 5"
1/ 4"
4"
REMOVE EXISTING
CONC. SLAB,
EXCAVATE FOR
NEW SLAB
8' - 9"
EXISTING WATER
LINE
EXISTING LP PIPING: TERMINATE
w/ NEW VALVE WHERE IT
EMERGES FROM UNDERGROUND;
DISPOSE OF UNUSED PIPE
REMOVE EXISTING UNUSED PIPE
STUBS; FILL HOLES w/ GROUT
EXISTING HOSE
BIBS TO REMAIN
SALVAGE EXISTING STONE
MASONRY VENEER FOR RE-
USE ON NEW WALL
REMOVE EXISTING SUPPORT
POSTS & EXCAVATE DOWN
TO EXISTING FOOTING FOR
NEW WALL
SALVAGE EXISTING STONE
MASONRY VENEER FOR
RE-USE ON NEW WALL
REMOVE EXISTING TUBE
STEEL SUPPORT POSTS &
ANCHOR PLATE; FLUSH-
CUT OR REMOVE ANCHOR
BOLTS & SEAL
REMOVE EXISTING STEEL
& PRECAST STAIR
ASSEMBLY & RAIL
F
D
A2.011H
NORTH END STAIR (KITCHEN)
3'
2" 3'
4"
3'
6'
1/
2"
9'
1/
4" 5'
7"
4' - 8"
REMOVE EXISTING STEEL
& PRECAST STAIR
ASSEMBLY & RAIL
EXISTING WALL SCONCE TO
REMAIN
EXISTING SURFACE-
MOUNTED CONDUITS TO
REMAIN
Level 1 0"
Roof 21' - 2 3/4"
Level 2 13' - 0"
EF D
NORTH END STAIR (KITCHEN)
EXISTING LP PIPING:
TERMINATE w/ NEW VALVE
WHERE IT EMERGES
FROM UNDERGROUND;
DISPOSE OF UNUSED PIPE
EXISTING
HOSE BIBS
TO REMAIN
REMOVE EXISTING
UNUSED PIPE STUBS;
FILL HOLES w/ GROUT
EXISTING MECH.
VENTS
FI
EL
D V
ER
IF
Y
TO
TA
L
ST
AI
R R
IS
E
EXISTING WALL
SCONCE TO
REMAIN, TYP (4).
EXISTING MECH.
LOUVER
EXISTING MECH. VENT
EXISTING ELECTRICAL
CONDUITS, TYP.
EXISTING ROOF
CANOPY, TYP.
REMOVE EXISTING
BOTTOM
CONCRETE SLAB
EXISTING CONCRETE
PAVEMENT
SALVAGE EXISTING STONE
MASONRY VENEER FOR
RE-USE ON NEW WALL
REMOVE EXISTING STEEL &
PRECAST STAIR ASSEMBLY,
RAILS & SUPPORT POSTS;
COORDINATE WORK w/ NEW
CONSTRUCTION TO
MINIMIZE DISRUPTION TO
LODGE OPERATIONS.
BEFORE BEGINNING ANY
OTHER WORK:
REMOVE EXISTING SOFFIT
ENCLOSURE TO INSPECT
EXISTING STEEL BEAM;
NOTIFY A/E IMMEDIATELY
OF ANY ABNORMALITIES.
Level 1 0"
Roof 21' - 2 3/4"
Level 2 13' - 0"
F D
NORTH END STAIR (KITCHEN)
EXISTING
HOSE BIBS
EXISTING MECH.
VENTS
EXISTING WALL
SCONCE TO
REMAIN, TYP (4).
EXISTING MECH.
LOUVER
EXISTING MECH. VENT
EXISTING ELECTRICAL
CONDUITS, TYP. EXISTING ROOF
CANOPY, TYP.
NEW BOTTOM
CONCRETE SLAB - SEE
STRUCT. DWGS
EXISTING CONCRETE
PAVEMENT
R
-1
1/
R
-1 1/
5' - 9 1/2" 11T @ 11" EA = 10' - 1" 11"
5' - 9 1/2" 11T @ 11" EA = 10' - 1" 10' - 2 1/2"
NEW MASONRY/CONCRETE
WALL WRAPPED w/ SALVAGED
MASONRY STONE VENEER
5H
A6.00
Typ
A6.00 7H
Typ
A6.00 10E
Typ
A6.00 10H
Typ
1B
A6.00
A6.00 4B
TOUCH UP PAINT ON
SIDING FROM
HANDRAIL/STAIR
REMOVAL, TYP.
PROVIDE MINOR SIDING
REPAIRS AS REQ'd.
F
D
4' - 3"
T
1" E
A
5'
1/
2"
CLEAR
3' - 7 1/2"
3"3"
BUILD NEW CMU SUPPORT
WALL w/ STONE VENEER TO
MATCH EXISTING
NEW CONC. SLAB
FOOTING: 54"x36"x12" -
SEE STRUCT. DWGS
A2.011D
1H
A6.00
3'
0"
4' - 6"
F
D
4' - 3"
4' - 4" 4' - 4"
T
1" E
A
5'
1/
2"
/2
T
1" E
A
5'
1/
2"
4' - 3"
CLEAR
3' - 11 1/4"
CLEAR
3' - 7 1/2"
3"
3"
9"
TRIM EXISTING STEEL
BEAM AS REQ'd; PAINT
CUT STEEL
A2.011D
1B
A6.00
1D
A6.00
1D
A6.00
SIM.
RA
DE
CTI E TET RS
ER
C G I
H
FO
ATS
ET GINI
VIR
TSWE
PAUL A.
2626NO.
WALKER A
© Copyright 2024 Paradigm Architecture sheet number:
checked by:
date:
sheet title:
revisions:
job number:
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H 1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12 13 drawn by:
2223 Cheat Road · Suite 300 Morgantown, WV 26508 tele 304-284-5015 304-284-5014 fax
5184 Caldwell Mill Road · Suite 204351 Hoover, AL 35244 tele 205-403-2742
PARADIGM
ARCHITECTURE
/2 /2
:3
:2
P M
A2.01
Blackwater Falls Lodge
Exterior Stair Repair/
Replacement
PAW
12.4.2024
North Stair
AEW
1584 Blackwater Lodge Rd, Davis, WV
26260
CONSTRUCTION
DOCUMENTS
N
PLAN
NORTH 1/4" = 1'-0"
10H Demo-Enlarged North Stair - Level 1 1/4" = 1'-0"
7H Demo-Enlarged North Stair - Level 2 1/4" = 1'-0"
1H Demo-North End Stair 1
1/4" = 1'-0" 1D North End Stair 1
1/4" = 1'-0" 10D Enlarged New North Stair - Level 1
1/4" = 1'-0" 7D Enlarged New North Stair - Level 2
5 1/2" 5 1/2"
11"
#3 HAIRPIN 1'-6" LG
SLEEVE
PLANSECTION
STAIR WIDTH
3"
1/
2"
1/ 2"
SLEEVE
#3 HAIRPIN 1'-6" LG
MIN.
3"
1-1/2" GALV. IPS STEEL
GUARDRAIL, PAINTED
PREFORMED,
SLEEVED, OR CORE
DRILLED POST HOLE
FILL WITH NON-
SHRINK…