Drawings- Bldg 123 - Roofing - 04042025.pdf

PDF 2 MB Posted

Attached to
Roof Repair B123
Solicitation number
W911SG25BA031
Issued by

About this file

These technical drawings are for a roof replacement project at Building 123 located at Fort Bliss, Texas. The project involves demolishing the existing roof system and installing a new asphalt shingle roof system. The site plan shows the building's location on Buford Road, with a detailed demolition work plan indicating the extent of the existing roof to be removed. The new work plan depicts the proposed roof configuration, including a built-up roof system. The drawings include a project information signage detail and are prepared by the Directorate of Public Works (DPW) Engineering Services Division for the U.S. Army at Fort Bliss.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text

FORT BLISS, TEXAS

AutoCAD SHX Text

INDEX OF DRAWINGS

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

CONCURRENCES

AutoCAD SHX Text

USING AGENCY

AutoCAD SHX Text

FIRE DEPARTMENT

AutoCAD SHX Text

ENVIRONMENTAL DIVISION

AutoCAD SHX Text

PHYSICAL SECURITY OFFICER

AutoCAD SHX Text

ANTI-TERRORISM/FORCE PROTECTION

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

SIGNATURES INDICATE THAT THOSE SIGNING HAVE REVIEWED PROJECT

AutoCAD SHX Text

PLANS AND SPECIFICATIONS AND ARE IN CONCURRENCE WITH THEM.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

SAFETY OFFICER

AutoCAD SHX Text

DATE

AutoCAD SHX Text

NEC

AutoCAD SHX Text

DATE

AutoCAD SHX Text

MASTER PLANNING DIVISION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OPERATIONS & MAINTENANCE DIVISION

AutoCAD SHX Text

INDUSTRIAL HYGIENE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

CHIEF, ENGINEERING SERVICES DIVISION, DPW

AutoCAD SHX Text

CHIEF, DESIGN BRANCH, ESD, DPW

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

BUILDING 123 ROOF REPLACEMENT

AutoCAD SHX Text

PROJECT LOCATION MAP

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text 1 = COVER SHEET 2 = SITE PLAN 3 = DEMOLITION WORK PLAN 4 = NEW WORK PLAN 5 = PROJECT INFORMATION SIGNAGE DETAIL

AutoCAD SHX Text

CVRSHT

AutoCAD SHX Text 04/04/2025

AutoCAD SHX Text

FE-10070-4J

AutoCAD SHX Text A.F.

AutoCAD SHX Text A.F.

AutoCAD SHX Text

BUILDING 123 ROOF REPLACEMENT

AutoCAD SHX Text

CASSIDY RD.

AutoCAD SHX Text

SHERIDAN RD.

AutoCAD SHX Text

DONIPHAN RD.

AutoCAD SHX Text

PERSHING RD.

AutoCAD SHX Text

CHAFFEE RD.

AutoCAD SHX Text

SLATER RD.

AutoCAD SHX Text

BLDG. 123

AutoCAD SHX Text

CUSTER RD.

W

FO

R T

B

LI

SS

N

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/04/2025

AutoCAD SHX Text

FE-10070-4J

AutoCAD SHX Text A.F.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text A.F.

AutoCAD SHX Text

PERSHING RD.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text CONSTRUCTION LIMITS - CONSTRUCTION AREA TO USE DEMARCATION POINTS SUCH AS FENCING, CURBS, ETC., WHEREVER FEASIBLE UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

REMOVE EXISTING ROOF SYSTEM

AutoCAD SHX Text LAY DOWN YARD TO BE SUBMITTED BY CONTRACTOR AND APPROVED BY COR & MASTER PLANNING

AutoCAD SHX Text

SLATER RD.

AutoCAD SHX Text

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

SCALE: 1"=50'

AutoCAD SHX Text

DONIPHAN RD.

AutoCAD SHX Text

LAY-DOWN AREA

AutoCAD SHX Text

BUFORD RD.

AutoCAD SHX Text

CONSTRUCTION LIMITS

AutoCAD SHX Text

BUILDING 123 ROOF REPLACEMENT

BLDG. 123

W

FO

R T

B

LI

SS

N

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

DEMOLITION WORK PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/04/2025

AutoCAD SHX Text

FE-10070-4J

AutoCAD SHX Text A.F.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text A.F.

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION WORK PLAN

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text

DEMOLITION WORK NOTES

AutoCAD SHX Text E

AutoCAD SHX Text

EXISTING ROOF SYSTEM

AutoCAD SHX Text

EXISTING CHIMNEY

AutoCAD SHX Text

EXISTING EXHAUST FANS

AutoCAD SHX Text

EXISTING PIPE PENETRATION

AutoCAD SHX Text

EXISTING ANTENNA

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

EXISTING EVAPORATIVE COOLER

AutoCAD SHX Text

EXISTING ABANDONED HVAC STAND

AutoCAD SHX Text

EXISTING DUCT PENETRATION

AutoCAD SHX Text

EXISTING ABANDONED DUCT PENETRATION

AutoCAD SHX Text

EXISTING FRESH AIR INTAKE

AutoCAD SHX Text

EXISTING EXHAUST FANS

AutoCAD SHX Text

EXISTING DOWN SPOUT

AutoCAD SHX Text

EXISTING ELECTRICAL PENETRATION

AutoCAD SHX Text E

AutoCAD SHX Text

EXISTING ABANDONED ELECTRICAL PENETRATION

AutoCAD SHX Text

BUILDING 123 ROOF REPLACEMENT

AutoCAD SHX Text 104'-4"

AutoCAD SHX Text 26'-2"

AutoCAD SHX Text 52'

AutoCAD SHX Text 26'-2"

AutoCAD SHX Text 9'-4"

AutoCAD SHX Text 56'-6"

AutoCAD SHX Text 2'

12'-9"

W

FO

R T

B

LI

SS

N

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

NEW WORK PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-102

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/04/2025

AutoCAD SHX Text

FE-10070-4J

AutoCAD SHX Text A.F.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text A.F.

AutoCAD SHX Text

AutoCAD SHX Text

NEW WORK PLAN

AutoCAD SHX Text

SCALE: 1/8"=1'-0"

AutoCAD SHX Text

NEW WORK NOTES

AutoCAD SHX Text E

AutoCAD SHX Text

NEW BUILT-UP ROOF SYSTEM

AutoCAD SHX Text

EXISTING CHIMNEY

AutoCAD SHX Text

EXISTING EXHAUST FANS

AutoCAD SHX Text

EXISTING PIPE PENETRATION

AutoCAD SHX Text

EXISTING ANTENNA

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text

EXISTING EVAPORATIVE COOLER

AutoCAD SHX Text

EXISTING DUCT PENETRATION

AutoCAD SHX Text

EXISTING FRESH AIR INTAKE

AutoCAD SHX Text

EXISTING EXHAUST FANS

AutoCAD SHX Text

EXISTING DOWN SPOUT

AutoCAD SHX Text

EXISTING ELECTRICAL PENETRATION

AutoCAD SHX Text

NEW FALL PROTECTION ROOF ANCHOR

AutoCAD SHX Text

NEW ASPHALT SHINGLE ROOF SYSTEM

AutoCAD SHX Text

BUILDING 123 ROOF REPLACEMENT

AutoCAD SHX Text 104'-4"

AutoCAD SHX Text 26'-2"

AutoCAD SHX Text 52'

AutoCAD SHX Text 26'-2"

AutoCAD SHX Text 9'-4"

AutoCAD SHX Text 56'-6"

AutoCAD SHX Text 2'

12'-9"

W

FO

R T

B

LI

SS

DHVLJQ DQG &RQVWUXFWLRQ

DLUHFWRUDWH RI PXEOLF

PURMHFW 1DPH

&RQWUDFWRU &RQWDFW &RQWUDFW�W���S*;;D�;;

IQIRUPDWLRQ TO� W���S*;;F�;;;

SXSHULQWHQGHQW� P0�

4$ 0DQDJHU

U.S.ARMY

SXSHUYLVHG E\�

SHUYLFHV DLYLVLRQ

FRUW BOLVV� TH[DV

WRUNV �(QJLQHHULQJ

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

PROJECT INFORMATION SIGNAGE DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text G-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 04/04/2025

AutoCAD SHX Text

FE-10070-4J

AutoCAD SHX Text A.F.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text A.F.

AutoCAD SHX Text 3"

AutoCAD SHX Text 9"

AutoCAD SHX Text 19"

AutoCAD SHX Text 10.5"

AutoCAD SHX Text 6.5"

AutoCAD SHX Text 3"

AutoCAD SHX Text 21"

AutoCAD SHX Text 3"

AutoCAD SHX Text 42"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 1.5"

AutoCAD SHX Text 3"

AutoCAD SHX Text 1.5"

AutoCAD SHX Text 3"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text 0.625"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text 7.875"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text 0.625"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text 0.625"

AutoCAD SHX Text 1.25"

AutoCAD SHX Text NOTES: 1. THE SIGNS ARE TO BE ERECTED AT A LOCATION THE SIGNS ARE TO BE ERECTED AT A LOCATION DESIGNATED BY THE COR AND SHALL CONFORM TO THE SIZE, FORMAT, AND TYPOGRAPHIC STANDARDS. 2. THE SIGN PANELS ARE TO BE FABRICATED FROM .75" HIGH THE SIGN PANELS ARE TO BE FABRICATED FROM .75" HIGH DENSITY OVERLAY PLYWOOD. 3. SIGN GRAPHICS TO BE PREPARED ON A WHITE SIGN GRAPHICS TO BE PREPARED ON A WHITE NON-REFLECTIVE VINYL FILM WITH POSITIONABLE ADHESIVE BACKING. 4. DRILL AND INSERT SIX (6) .375" T-NUTS FROM THE DRILL AND INSERT SIX (6) .375" T-NUTS FROM THE FRONT FACE OF THE SIGN PANEL. FLANGE OF T-NUT TO BE BLUSH WITH SIGN FACE. 5. SIGN UPRIGHT TO BE STRUCTURAL GRADE 4"X4" TREATED SIGN UPRIGHT TO BE STRUCTURAL GRADE 4"X4" TREATED DOUGLAS FIR OR SOUTHERN YELLOW PINE. NO. 1 OR BETTER. DRILL SIX (6) .375" MOUNTING HOLES IN UPRIGHTS TO ALIGN WITH T-NUTS IN SIGN PANEL.COUNTERSINK (.5") BACK OF HOLE TO ACCEPT SOCKET HEAD CAP SCREW (4" X .375") 6. MINIMUM DISTANCE BETWEEN BOTTOM OF SIGN AND MINIMUM DISTANCE BETWEEN BOTTOM OF SIGN AND GROUND SHALL BE 4'.

AutoCAD SHX Text

PROJECT INFORMATION SIGNAGE DETAIL

AutoCAD SHX Text

NOT TO SCALE

BUILDING 123 ROOF REPLACEMENT

Sheets and Views
Bldg 123 - Roofing-CVRSHT
Bldg 123 - Roofing-A-100-SITE
Bldg 123 - Roofing-A-101-DEMO
Bldg 123 - Roofing-A-102-NEW
Bldg 123 - Roofing-G-100-PR-INFO

File details come from the government source that posted it. Updated .