Drawing files _ 260184 _ Mech.pdf

PDF 15 MB Posted

Attached to
W91QVN22R0024 Repair Barracks, BLDG No. 823, Camp Hovey, Korea
Solicitation number
W91QVN22R0024
Issued by

View the file

Other files

File Type Posted
Drawing files _ 260184 _ Civil.pdf PDF
Drawing files _ 260184 _ Arch.pdf PDF
A21 W91QVN-22-R-0024.pdf PDF
Drawing files _ 260184 _ Title.pdf PDF
Drawing files _ 260184 _ Elec.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

o

ACCU AIR COOLED CONDENSING UNIT

ACLD AIR COOLED

ACU AIR CONDITION UNIT (S)

ACV ALARM CHECK VALVE

ADP APPARATUS DEW POINT

AHU AIR HANDLING UNIT

AIR COND AIR CONDITION (-ING,-ED)

AL ALUMINUM

ALT ALTITUDE

AMB AMBIENT

AMP AMPERE(AMP, AMPS)

APPROX APPROXIMATE

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

BARO BAROMETER(-TRIC)

BARO PR PRESSURE, BAROMETRIC

BHP BRAKE HORSEPOWER

BP BOILING POINT

CAP CAPACITY

CCW COUNTER CLOCKWISE

CHW CHILLED WATER

CKT CIRCUIT

CLASS CLASSIFICATION

CLG LOAD COOLING LOAD

COEF COEFFICIENT

CONN CONNECTION

CONT

C

CMH CUBIC METER PER HOUR

CU M CUBIC METER

CENTIGRADE/ CELCIUS

CFCI

CONTRACTOR INSTALLED

CONTRACTOR FURNISHED

CIP CAST IRON PIPE

CWP

CU MM CUBIC MILLIMETER

Cv COEFFICIENT, VALVE FLOW

CW CLOCKWISE OR COLD WATER

CIRCULATING WATER PUMP

DB DECIBEL OR DRY BULB

COMPRESSORCPRSR

DBT DRY BULB TEMPERATURE

DCWS DOMESTIC COLD WATER SUPPLY

DEG or ° DEGREE

DFW DIESEL OIL

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATER SUPPLY

DHWR

DHWS

DIRECT EXPANSIONDX

DRY PIPE VALVEDPV

DOUBLE POLE DOUBLE THROWDPDT

DEWPOINT TEMPERATUREDPT

DIVISIONDIV

DIFFERENCEDIFF

DIAGRAMDIAG

DIAMETERDIA or

DWG DRAWING

EXPANSION JOINTEXPJT

ENTERING WATER TEMPEWT

EVAPORAT (-E,-ING,-ED,-OR)EVAP

EXTERNAL STATIC PRESSUREESP

EXPLOSION PROOFEP

EQUIPMENTEQPT

ENTERINGENT

EFFICIENCYEFF

EQUIVALENT DIRECT RADIATIONEDR

ECONOMIZERECON

ECCENTRICECC

ENTERING AIR TEMPERATUREEAT

FUEL OILFO

FA FACE AREA OR FRESH AIR

FHC FIRE HOSE CABINET

FHY FIRE HYDRANT

FLA FULL LOAD AMPERES

F FARENHEIT

FLR FLOOR

FEED WATER PUMPFWP

FACE VELOCITYFVEL

FLUSH VALVEFV

FRP

FREQUENCYFREQ

FEMALE PIPE THREADFPT

FIBERGLASS REINFORCED PLASTIC

Ft or ' FEET

FXTR FIXTURE

GALVANIZED STEELGALVS

GAGE OR GAUGEGA

GR GRAMS

GOVERNMENT INSTALLED

GOVERNMENT FURNISHED GFGI

CONTRACTOR INSTALLED

GOVERNMENT FURNISHEDGFCI

GAL GALLONS

GALLONS PER MINUTEGPM

HERTZHZ

HORIZONTALHORIZ

HOT WATER HEATERHWH

HOT WATERHW

HOUR(S)HR

HORSEPOWERHP

MERCURYHG

HEADHD

HB HOSE BIBB

DIAMETER, INSIDEID

ISOMETRICISO

IRON PIPE SIZEIPS

J JOULE

K THERMAL CONDUCTIVITY

K THERMAL CONDUCTIVITY

kG kCAL/HR

KILOGRAM

kG/SQ CM KILOGRAM PER SQ. CENTIMETER kG/SQ CM A

KILOCALORIE PER HOUR

(ABSOLUTE)

KILOGRAM PER SQ. CENTIMETER

kG/SQ CM G

(GAUGE)

KILOGRAM PER SQ. CENTIMETER

kG/SM KILOGRAM PER SQ. METER kG/SM A kG/SM G

(ABSOLUTE)

KILOGRAM PER SQ. METER

KILOGRAM PER SQ. METER (GAGE)

kW KILOWATT kWH KILOWATT HOUR kJ KILOJOULE kPa KILO PASCAL

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LG LENGTH

LH LATENT HEAT

LWT LEAVING WATER TEMPERATURE

LIQUID LINELL

L LITERS

LPD LITERS PER DAY

LPH LITERS PER HOUR

LPS

LM LINEAR METER

LITERS PER SECOND

LAV LAVATORY

LPM LITERS PER MINUTE

LT LAUNDRY TRAY

NUMBERNO

NORMALLY OPENN.O.

NOT IN CONTRACTNIC

NORMALLY CLOSEDN.C.

NOISE CRITERIANC

NCK

MAX

NOT TO SCALENTS

MIN

MPH

M METERS

MAXIMUM

MINIMUM OR MINUTE

METERS PER HOUR

MPS METERS PER SECOND

MM MILLIMETER

NPT NATIONAL TAPER PIPE (THREAD)

NOT APPLICABLEN/A

NECK

MECH MECHANICAL

OS&Y OUTSIDE SCREW & YOKE

OD

OAIL OUTSIDE AIR INTAKE LOUVER

OA OUTSIDE AIR

OUTSIDE DIAMETER

OPNG OPENING

OXY OXYGEN

PERCENT

PRESSURE REDUCING VALVEPRV

PARTS PER MILLIONPPM

POINT OF CONNECTIONPOC

PLUMBINGPLMB

PHASE (ELECTRIC)PH

PRESSURE GAGEPG

PD

POLEP

PRESSURE DROP OR DIFFERENCE

Pa PASCAL

POL PETROLEUM, OIL AND LUBRICANTS

QUANTITYQTY

QUARTQT

REFRIGERATION TONRT

REVOLUTIONS PER MINUTERPM

RADIATORRDTR

RETURN AIRRA

THERMAL RESISTANCER

REFRIGERANT (134A, 22, ETC)R134A,R22

RH RELATIVE HUMIDITY

SUPPLY AIRSA

SYMBOLSYM

SUCTIONSUCT

STORAGESTOR

STEELSTL

STANDARDSTD

STEAMST

SAYBOLT SECONDS UNIVERSALSSU

STAINLESS STEELSST

SAYBOLT SECONDS FUROLSSF

SQUARESQ

SPECIFICATIONSPEC

SINGLE POLE DOUBLE THROWSPDT

SM

LPH, STANDARD CONDITIONSSLPH

LPS, STANDARD CONDITIONSSLPS

SG

SLPD LPD, STANDARD CONDITIONS

SL SENSIBLE LOAD

SH SENSIBLE HEAT

SPECIFIC GRAVITY

SF SAFETY FACTOR

SEC SECOND

SCH SCHEDULE

STATIC PRESSURE

SQUARE METER

SP

SBM

SAN SANITARY

SUBMERSIBLE

TYPICALTYP

THERMOSTATTSTAT

TONS OF REFRIGERATIONTONS

THICKNESSTHK

THERMOMETERTHERM

TEMPERATURETEMP

TEMPERATURE DIFFERENCETD

UNIT HEATERUH

HEAT TRANSFER COEFFICIENTU

WTRPRF

WT

WSHR

WITHW/

WH

WIDTHWD

WCLD

WC

WBT

WB

WATTW

VP

VOL

VISC

VERTICALVERT

VENTILATIONVENT

VELOCITYVEL

VARIABLE AIR VOLUMEVAV

VAC VACUUM

VLV VALVE

V VOLT

WATERPROOF

WEIGHT

WASHER

WATTHOUR OR WATER HEATER

WATER-COOLED

WATER CLOSET

WET BULB TEMPERATURE

WET BULB

PRESSURE, DYNAMIC(VELOCITY)

VOLUME

VISCOSITY

VTR VENT THRU ROOF

UR URINAL

PRESSURE RELIEF

TEMPERATURE

EXPANSION LOOP

EXPANSION JOINT

ANCHOR, INTERMEDIATE

ALIGNMENT GUIDE

AIR VENT, AUTOMATIC

SQUARE HEAD BALANCING COCK

QUICK OPENING

NEEDLE

LOCK SHIELD

FLEXIBLE CONNECTOR

FLOWMETER, ORIFICE

FLOWMETER, VENTURI

FLOW SWITCH

PRESSURE GAUGE AND COCK

STRAINER

THERMOMETER

PRESSURE REDUCING

RELIEF OR SAFETY

SLEEVE

BLOW OFF STRAINER

INLINE PUMP

SAFETY

FLOAT

valves, special duty

GATE, NORMALLY CLOSED

GLOBE

SOLENOID

3 WAY MANUAL

GATE, NORMALLY OPEN

PLUG

MOTOR OPERATED GATE

MOTOR OPERATED GLOBE

3 WAY ELECMOTOR CONTROL

3 WAY AIR MOTOR CONTROLLER

HOSE GATE

HOSE GLOBE

POST INDICATOR

OS Y

ANGLE GLOBE

ANGLE GATE

SWING GATE CHECK

ALARM CHECK

DRY PIPE

DELUGE

PREACTION

TAMPER DETECTION SWITCH

QUICK OPENING DEVICE

NON-RISING STEM

DIAPHRAGM

SOLENOID

MOTOR ELECTRIC

valve actuators

POTABLE COLD WATER

POTABLE HOT WATER

POTABLE HOT WATER RETURN

PIPE SLEEVE

BACKFLOW PREVENTER

PITCH OR PIPE, UP(U), DOWN(D)

VENT THRU ROOF

SURFACE CLEANOUT

FLOOR CLEANOUT

FLOOR DRAIN

PIPE SLEEVE WITH FIRE STOPPING

HOSE BIBB

FLOOR SINK (200mm x 200mm)

HOT WATER (60°C)

HOT WATER (82.22°C)

VENT

SANITARY SEWER

COMPRESSED AIR

FUEL OIL SUPPLY

FUEL OIL RETURN

FLOOR DRAIN WITH CLEANOUT

FLOOR DRAIN WITH DEEP TRAP

FLOOR DRAIN WITH NO TRAP

FLOOR DRAIN WITH TRAP TIME

FIRE PROTECTION WATER SUPPLY

MAIN SUPPLY SPRINKLER

WET STANDPIPE

DRY STANDPIPE

COMBINATION STANDPIPE

plumbing sprinkler

82.22°C

60°C

LOW PRESSURE CONDENSATE

BOILER BLOW DOWN

PUMPED CONDENSATE

VACUUM PUMP DISCHARGE

MAKE UP WATER

FUEL OIL DRAIN

FUEL OIL TANK VENT

FUEL OIL GAUGE

FUEL OIL SUPPLY

FUEL OIL RETURN

CONTROL AIR MAIN

DUAL TEMPERATURE RETURN

FILL LINE

MAKE UP WATER

DUAL TEMPERATURE SUPPLY

WATER SUPPLY

LOW TEMPERATURE HOT

WATER RETURN

LOW TEMPERATURE HOT

SPLITTER DAMPER

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION

REFRIGERANT LIQUID

DRAIN

CHILLED WATER SUPPLY

CHILLED WATER RETURN

dampers piping heating air conditioning and refrigeration

DIRECTION OF FLOW

FLEXIBLE CONNECTION

TRANSITION

(810mm WIDTH x 400mm DEPTH)

DUCT SIZES SHOWN

RISE(R), DOWN(D)

CHANGE OF ELEVATION

VERTICAL OR HORIZONTAL

ACCESS DOOR,

FIRST FIGURE IS ON TOP

POSITIVE PRESS.,

OUTSIDE AIR DUCT SECTION,

FIRST FIGURE IS ON TOP

POSITIVE PRESS.,

SUPPLY AIR DUCT SECTION,

FIRST FIGURE IS ON TOP

SECTION, NEGATIVE PRESS.,

RETURN OR EXHAUST AIR DUCT

SUPPLY OR RETURN

FLEXIBLE AIR DUCT,

TRANSITION

SQUARE TO ROUND

REGISTER, CEILING

EXHAUST AIR GRILLE OR

REGISTER, SIDEWALL

SUPPLY AIR GRILLE OR

REGISTER, CEILING

RETURN AIR GRILLE OR

OR REGISTER, CEILING

SUPPLY AIR MODULAR DIFFUSER

DOOR GRILLE (300mmx150mmH)

(500mmWx300mmH, 94.4 LPS)

LOUVER, DOOR OR WALL

(13mm, 47.2 LPS)

DOOR UNDERCUT

duct works grilles, registers and diffusers

CONTINUE / CONTINUATION

fittings

TEE, SINGLE SWEEP

UNION, SCREWED

UNION, FLANGED

CONNECTION, TOP

ELBOW, 90°

ELBOW, TURNED UP

ELBOW, TURNED DOWN

TEE, OUTLET UP

TEE, OUTLET DOWN

CONNECTION, BOTTOM

REDUCER, CONCENTRIC

(STRAIGHT, INVERT)

REDUCER, ECCENTRIC

(STRAIGHT, DOWN)

REDUCER, ECCENTRIC

TEE

ELBOW, 45°

LATERAL

SOLVENT CEMENT

BELL AND SPIGOT

SCREWED

FLANGED

WELDED

SOLDERED/BRAZED

M

NS

BUTTERFLY

BALL

DIAPHRAGM

GATE

INDICATING BUTTERFLY

KEY OPERATED

CHECK

DELUGE VALVE

WALL MOUNTED TEST HEADER

FIRE ALARM BELL

HOSE STATION DRY STANDPIPE

MINI HORN

HORN SPEAKER

WALL HYDRANT 2 HOSE OUTLET

SMOKE DETECTOR

CUTTING POINT

CAP

NON-SPRINKLERED SPACE

RISER

CONNECTION (2-WAY SHOWN)

SIAMESE FIRE DEPARTMENT

CONNECTION

SINGLE FIRE DEPARTMENT

valves

UPRIGHT SPRINKLER (K=5.6)

SIDEWALL SPRINKLER (K=5.6)

UPRIGHT SPRINKLER (K=8.0)

PENDENT SPRINKLER (K=5.6)

PENDENT SPRINKLER (K=8.0)

RESIDENTIAL PENDENT SPRINKLER (K=4.9)

M-1

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

A B B R E V I A T I O N S

MECHANICAL MATERIAL INDICATIONS AND SYMBOLS

FS

VFM

OFM

AVA

S

M

S

M

P

M

M

FD

FCO

SCO

200x200

DSP

WSP

CSP

S

F

PLAN ELEV

S

A

FOS

FOR

RD

RS

RL

D

CWS

CWR

LPC

BBD

PC

VPD

MU

FOD

FOV

FOG

FOS

FOR

HWS

M

HCS

HCR

FILL

MU

HWR

DU 13mm

47.2

94.4

DG

300x150

500/300L

R

AD

FC

SG

SR

RG

RR

810mm x 400mm

810mm x 400mm

810mm x 400mm

EG

ER

810mm x 400mm

LEGEND & ABBREVIATION

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

CAMP CASEYCHONG, ST

260184

FIRE PROTECTION AND MECHANICAL GENERAL NOTES

A. REPAIR/MAINTENANCE (K-WORK)

SCOPE OF WORK

NOTE :

NECESSARY DUCT CONNECTION TO FUNCTION AS ORIGINALLY INTENDED.

NEW PIPING INSTALLATION, REMOVE THE EXIST DUCTWORK AND INSTALL NEW DUCTWORK AND MAKE ALL

DUCTWORK AND PIPING ELEVATION/LOCATION. IF THE EXIST DUCT ELEVATION IS CONFLICTED WITH

9. PRIOR TO INSTALL NEW HVAC AND PLUMBING PIPING CONTRACTOR MUST COORDINATE WITH THE EXIST

NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.

8. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWINGS. SHOP DRAWING SHALL

BE VERIFIED AT THE JOB SITE.

7. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. APPROXIMATE AND SHALL

6. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.

CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.

5. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.

4. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.

UL LISTED.

DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE

3. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE

TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.

2. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER

FLEXIBLE DUCTWORK FOR VIBRATION ISOLATION.

1. ALL EQUIPMENT CONNECTIONS TO DUCTWORK SHALL HAVE A MIN. OF 100MM OF REINFORCED CANVAS

LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.

24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, AND THE

WITHIN 1M OF THE UNIT.

23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH SHUT-OFF VALVE

FLUSHED IS CLEAR AS TAP WATER.

22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL ALL WATER BEING

ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.

PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT. PROVIDE SPIN-IN TYPE FITTINGS AT

21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR USE RADIUS ELBOWS.

BODIES EXPOSED TO AIR BELOW THE FLOOR.

AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION, FROM SINK

20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1/4 INCH PER 1 FOOT. INSULATE ALL SEWER PIPING RECEIVING

PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR CONCEALED CEILINGS.

COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.

AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"x12" ACCESS PANELS FOR TWO VALVES.

ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS

19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS IN DUCTS AT

CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.

18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC PRESSURE

TO THE PROJECT COR FOR GOVERNMENT REVIEW AND APPROVAL.

MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB) REPORT SHALL BE SUBMITTED

APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL SPECIFICATIONS FOR

17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE WITH

CONTRACTING OFFICER FOR APPROAL.

PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL BE

GOVERNMENT.

DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE U.S.

15. FOR O & MA PROJECTS, KOREA, DECEMBER 30, 2015 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT. THE

14. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.

OR REPLACED BY THIS CONTRACTOR.

EQUIPMENT, DUCT WORK, PIPING ETC. DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED

13. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE THE EXISTING EQUIPMENT ANY

EQUIPMENT AND ELECTRICAL ITEMS.

THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT NO ADDITIONAL COST TO

12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY TO

PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER.

11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS

EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.

9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.

7. INSTALL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.

6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.

TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTORS TEST VALVES AND DRAINS.

5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED

FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLIES.

PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,

4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF

PIPES LESS THAN 50 MM (2 INCHES) IN NOMINAL.

OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND

CONFORMING TO ASME/ANSI A13. 1-1996, "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE

3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER (26 FT) INTERVALS, WITH PLASTIC WRAPAROUND TYPE PIPE LABELS

APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.

2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED WITH

APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT SPECIFICATION.

HEADS LOCATIONS WITH, LIGHTING FIXTURES, AND HVAC DEVICES. ALL EQUIPMENT SHALL BE UL LISTED AND/OR FM

CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. CONTRACTOR SHALL COORDINATE SPRINKLER

1. THE EQUIPMENT SHOWN ARE SUGGESTED LOCATIONS HOWEVER FINAL LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE

M-2

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

GENERAL NOTES & SCOPE OF WORK

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

CAMP CASEYCHONG, ST

260184

MECHANICAL ROOM. PROVIDE FINAL-AIR LEAKAGE TEST REPORT.

CEILING AND PENETRATORS (DUCT, WATER PIPING, CONDUCT PIPE, FLUE VENT PIPE AND ETC) AT

ROOM. REPAIR INFILTRATION AND SEAL AIR LEAKING PORTIONS INCLUDING CLEARANCE BETWEEN WALL,

8. PRE-AIR LEAKING TEST IS REQUIRED PRIOR TO REPAIR INFILTRATION AND SEALING AT MECHANICAL

ASSOCIATED ACCESSORIES, FOR FIRE PROTECTION SYSTEM AS SHOWN ON DRAWINGS.

7. REPLACE DETERIORATED EXISTING AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM, AND ALL

ON DRAWINGS. (EXISTING DOMESTIC HOT WATER HEATER EXCLUDED)

INSUSLATIONS, CONTROL WORK, EQUIPMENT SUPPORT, AND ALL ASSOCIATED ACCESSORIES AS SHOWN

PLUMBING FIXTURES, ELECTRIC WATER COOLERS, VALVE BOXS FOR WASHING MACHINES, VALVES, PIPES, AND VENT PIPING SYSTEM INCLUDING DOMESTIC HOT WATER STORAGE TANKS, PUMPS, EXPANSION TANK,

6. REPAIR THE PLUMBING SYSTEM BY REPLACING DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER

OPERATIONAL, SUCH AS EQUIPMENTS AND CONTROLS.

5. PERFORM COMMISSIONING AFTER CONSTRUCTION TO VERIFY THAT THE HVAC SYSTEM IS FULLY

4. REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ALL DRYER VENT & CAPS WITH NEW.

CONSTRUCTION TO VERIFY IF THE HVAC SYSTEM WORKS PROPERLY.

3. PERFORM DALT (DUCT AIR LEAKAGE TEST) AND T.A.B (TESTING, ADJUSTING, AND BALANCING) AFTER

SHOWN ON DRAWINGS.

2. PROVIDE NEW ELECTRICAL UNIT HEATER AND CEILING MOUNTED EXHAUST FANS FOR H.V.A.C SYSTEM AS

DRAWINGS. (EXISTING BOILER EXCLUDED)

THERMOSTAT, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON

DIFFUSERS, GRILLES, RANGE HOOD, VALVES, DAMPERS, PIPES, INSULATIONS, CONTROL WORK, ROOM

PUMPS, EXPANSION TANK, AIR SEPARATOR, AIR CONDITIONING UNITS, UNIT HEATER, DUCTS, LOUVERS, DETERIORATED AIR HANDLING UNITS, H.V UNITS, FAN COIL UNITS, EXHAUST FANS, RANGE HOOD,

1. REPAIR THE H.V.A.C (HEATING, COOLING AND VENTILATION) SYSTEM BY REPLACING EXISTING

ITEM NO

AHU

Q'TY SERVICE TYPE

CMH

50.3

HP VOLT/PH/HZ

MOTOR

6.7

ITEM NO Q'TY SERVICE TYPE

509 1,552

FAN COIL UNIT

FLOOR MTD. TYPE

VERTICAL CABINET

NOTEREMARKS

W VOLT/PH/HZ

115/1/60

300 115/1/60

115/1/60

115/1/60

(CMH)

CAPACITY

AIR

4,438

3,981

6,357

2,400

8,140

6,830

11,530

DB WB

COOLING COIL

LPM

(°C)

EWT

(INCH)

MAX WPD

HEATING COIL

4,070

14,890

13,360

22,550

(°C)

EAT

(°C)

EWT

71.0

ITEM NO Q'TY SERVICE TYPE

EF

EF

EF

EF

EF

EF

EF

EXHAUST FANS

REMARKS

1 4

HP VOLT/PH/HZ

115/1/60

FAN MOTOR

208/3/60

115/1/60

1/4 115/1/60

1/4 115/1/60

1/2 115/1/60

1 4

1 2

1 2

1 2 3

RPM

1,080

1,135

1,400

0.25

(INCH)

ESP

0.9

0.25

0.5

DIRECT DRIVEN, CENTRIFUGAL FAN

CEILING MOUNTED,

3 BIRD SCREEN 4 CEILING GRILLE

ITEM NO Q'TY SERVICE TYPE

ET

ET

EXPANSION TANK

BLADDER TYPE

BLADDER TYPE

REMARKS

VOLUME (GAL)

ACCEPTANCE

PRESSURE (PSI)

MAX. WORKING

E Q U I P M E N T S C H E D U L E S - 1

FCU

FCU

FCU

FCU

(mm DIA x mm HEIGHT)

TANK SIZE

600 x 2,030

600 x 1,530

1ST FL. ISSUE ROOM

LIVING/SLEEPING RM

KITCHEN & LOUNGE

2ND & 3RD FL.

MOUNTED CONCEALED TYPE

HORIZONTAL CEILING

MOUNTED CONCEALED TYPE

HORIZONTAL CEILING

MOUNTED CONCEALED TYPE

HORIZONTAL CEILING

W/VIBRATION ISOLATOR

W/VIBRATION ISOLATOR

W/VIBRATION ISOLATOR

(KCAL/HR)

HEAT CAP.

21 71.0

21 71.0

21 71.0

(KCAL/HR)

SENSIBLE

(KCAL/HR)

TOTAL EAT(°C)

19.5

19.5

19.5

19.5

1,650

2,310

DIRECT DRIVEN, CENTRIFUGAL FAN

CEILING MOUNTED,

0.25 700 115/1/60 1 4

FOR 1ST FL. TOILET

EXHAUST AIR FAN

FOR LAUNDRY AREA

EXHAUST AIR FAN

FAN FOR MUD ROOM

CEILING EXHAUST AIR

FOR LOUNGE, GAME RM, JAN

ROOF EXHAUST AIR FAN

FOR BATH ROOMS

ROOF EXHAUST AIR FAN

FOR MECH. RM

WALL EXHAUST AIR FAN

DIRECT DRIVEN, CENTRIFUGAL FAN

IN-LINE DUCT MOUNTED TYPE,

DIRECT DRIVEN, CENTRIFUGAL FAN

CEILING MOUNTED,

BELT DRIVEN, CENTRIFUGAL FAN

ROOF MOUNTED,

BELT DRIVEN, CENTRIFUGAL FAN

ROOF MOUNTED,

BELT DRIVEN, CENTRIFUGAL FAN

WALL MOUNTED,

6,800

1,020

1,780

1,330

3,570

0.375

0.375

1,550

1,045

1.0Amp

4.4Amp

(CMH)

CAP.

AIR

3 5

3 5

5 PREFABRICATED ROOF CURB.

ITEM NO

Q'TY SERVICE

TYPE

DRAW-THRU HORIZONTAL

DRAW-THRU HORIZONTAL

CMH

SUPPLY FAN

1,020

30.8

31.5

HP VOLT/PH/HZ

MOTOR

1/2

208/3/60

208/3/60

72,420

REMARKS NOTE

AIR HANDLING UNIT

7,530

(mmAq)

TSP

REMARKS

HEATING COILCOOLING COILSUPPLY FAN

SIZE

FILTER

100%

EAT(°C)

DB WB

32.7

25.5

LAT(°C)

DB WB

17.4

16.2

(°C)

EWT

5.6

(°C)

WTR

212.4

LPM

14.0

(mmAq)

APD

MAX

WPD

MAX

0.92M

MAKE-UP

OUTSIDE AIR

HORIZONTAL

DRAW-THRU

2.5

(M/SEC)

FACE VEL

(KCAL/HR)

TOTAL

107,938

EWT(°C)

71.0

WTR(°C)

5.6

EAT(°C)

LAT(°C)

-15.5

(mmAq)

PD

7.11

AREA

FILTER

1.55SM

O.A

CMH

7,530

PERCENT

HEATING & VENTILATING UNIT

NOTE

COMB. FILTER & MIXING BOX

VIBRATION ISOLATOR W/

W/FACE & BY-PASS DAMPER W/

HV

HV

MUD ROOM

LAUNDRY ROOM 6,800

(mmAq)

TSP

RPM

1,300

743 2

HEATING

(KCAL/HR)

TOTAL

10,863

EAT(°C)

LAT(°C)

-15.5

-15.5

(°C)

EWT

217.6

(LPM)

FLOW RATE

32.6

W/COMBINATION FILTER & MIXING BOX

W/VIBRATION ISOLATOR W/FACE & BY-PASS DAMPER

BY-PASS DAMPER W/FLAT FILTER

W/VIBRATION ISOLATOR W/FACE &

(M/SEC)

FACE VEL

2.5

2.5

AREA

FILTER

0.93SM

0.52SM

3.81

WPD

MAX

0.92M

(mmAq)

APD

MAX

0.92M3.81

SUPPLY FAN

EF

DIRECT DRIVEN, CENTRIFUGAL FAN

CEILING MOUNTED,

0.25 675 115/1/60 1 4

BATH ROOM

JANITOR ROOM 100

4TH FL. GAME RM

MULTI PURPOSE ROOM

ITEM NO Q'TY

AS

AIR SEPARATOR

REMARKS

INLET OUTLET

WATER SYSTEM

HOT/CHILLED

SERVICE TYPE

PIPE MOUNTED

PIPE SIZE

100 DIA 100 DIA WITH STRAINER

LOBBY & CORRIDOR

1ST, 2ND, 3RD & 4RD FL.

208/3/60 x50THK

(6)400x625

128 0.65Amp

0.53Amp

1,830

CHILLED WATER SYSTEM

HOT WATER SYSTEM

M-3

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

EQUIPMENT SCHEDULES - 1

VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT REQUIRMENTS.

1. QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

GENERAL NOTE

1 W/BACKDRAFT DAMPER 2 W/DISCONNECT SWITCH

6. 3 YEARS WARRANTY.

REQUIREMENTS.

5. COIL CAPACITY SHALL BE BASED ON THE COOLING

4. FIBER GLASS FILTER.

PACKAGE AS INDICATED ON DETAIL DWG.

3. EACH UNIT SHALL INCLUDE MANUFACTURER VALVE

2. UNIT SHALL BE PROVIDED WITH SUB-BASE AND COVER.

1. UL & AHRI440 OR KS B 6377 & KC CERTIFIED PRODUCTS.

(KCAL/HR)

TOTAL

71,366

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

2. 3 YEARS WARRANTY.

APPROVED EQUAL.

1. MFR. "LG ELEC" OR

2. 3 YEARS WARRANTY.

1. MFR. "LG ELEC" OR APPROVED EQUAL.

ITEM NO Q'TY SERVICE TYPE

CP

HP

REMARKS

HP VOLT/PH/HZ

208/3/60

FAN MOTOR

208/3/60

115/1/60

RPM

PUMPS

CENTRIFUGAL TYPE

BASE MOUNTED END SUCTION

CENTRIFUGAL TYPE

PIPE MOUNTED IN-LINE

CENTRIFUGAL TYPE

PIPE MOUNTED IN-LINE

(M)

HEAD

1,750

1,750

1,750 1/4

CONSTRUCTION

ALL BRONZE

CONSTRUCTION

ALL BRONZE

ITEM NO Q'TY

ELECTRIC WATER COOLER

E Q U I P M E N T S C H E D U L E S - 2

EWC

DESCRIPTION

ITEM NO Q'TY SERVICE TYPE

REMARKS

VOLT/PH/HZ

ITEM NO Q'TY SERVICE TYPE

RH

REMARKS

1 2 32.5

VOLT/PH/HZ

115/1/60

FAN MOTOR

(CFM)

CAPACITY

FAN

RANGE HOOD

KITCHEN

HOOD VENTED TYPE

STAINLESS STEEL

AMPS

3 CHARCOL AND WASHABLE GREASE FILTER

5,745

(mm)

HOOD SIZE

750 X 500

SP

115/1/601/6

STORAGE TANK SUMP

DOMESTIC HOT WATER

RECIRC. PUMP

DOMESTIC HOT WATER

CIRC. PUMP

DOMESTIC HOT WATER

SUBMERSIBLE SUMP TYPE -

1-1/2

(LPM)

CAP.

ON-OFF DIFF./AL SWITCH

W/BULT-IN AUTOMATIC

ITEM NO Q'TY SERVICE TYPE

REMARKS

(GAL)

CAPACITY

TANK

DOMESTIC HOT WATER STORAGE TANK

HWT

ENTIRE BUILDING

HORIZONTAL TYPE

STEEL ROUND

(mmDIA x mmLONG )

TANK SIZE

1,650 x 3,500

CEMENT-LINED STEEL TANK, 150 PSI.

ASME CODE REQUIREMENTS COMPLETE,

2,000

AIR CONDITIONING UNIT

CU

CU

LAUNDRY ROOM

ONLY SPLIT SYSTEM

DUCT-FREE COOLING

ITEM NO Q'TY SERVICE TYPE

REMARKS

EUH

ELECTRIC UNIT HEATER

MECH. ROOM

DISCHARGE TYPE

HORIZONTAL

(KW)

CAPACITY

HEATING

VOLT/PH/HZ

FAN CAPACITY

LPS

193.5 1,650

RPM HP

1/40 208/1/60

LAUNDRY ROOM

ONLY SPLIT SYSTEM

DUCT-FREE COOLING

5,745

(Kcal/HR)

CAPACITY

TOTAL

CONDENSING UNIT

COMPRESSOR

FLA RLA

12.9 62.5

12.9 62.5

VOLT/PH/HZFLA

0.7

0.7

CONDENSER FAN

208/1/60

208/1/60

208/1/60

208/1/60

EVAPORATOR UNIT(HIGH WALL TYPE)

VOLT/PH/HZCMH

884 1/16

884 1/16

208/1/60

208/1/60

SUPPLY AIR FAN

HP

DX - COOLING COIL

3,855

3,855

EER

10.95

10.95

R-410A

R-410A

REFRGERANT

DB WB

26.7

19.4

(Kcal/HR)

SENSIBLE CAP. EAT(°C)

19.4

26.7

PACKAGE

LOW AMTSIENT

DOWN TO -28°C

DOWN TO -28°C

ITEM NO Q'TY SERVICE TYPE

REMARKS

MECH. ROOM

DISCHARGE TYPE

HORIZONTAL

VOLT/PH/HZ

FAN CAPACITY

CFM

2,290 1,050

RPM HP

1/10

UNIT HEATER

UH

(KCAL/HR)

CAPACITY

HEATING

19,170

DISCONNECT SWITCH & THERMOSTAT

PROVIDE UNIT MOUNTED

LPM

10.0

(°C)

EWT

(°C)

EAT

57.6 71.0 115/1/60

755.5

417.3

127.1

37.9

16.8

7.9

3.9

4.6

3. 3 YEARS WARRTENTY.

2. MFR. "LG ELEC" OR APPROVED EQUAL.

1. EACH UNIT SHALL BE PROVIDED W/ WIRED REMOTE CONTROLLER.

HOT WATER CIRC. PUMP

DRP

DCP

208/3/60

CENTRIFUGAL TYPE

BASE MOUNTED END SUCTION

1,750 5755.5 16.8

CIRC. PUMP

CHILLED WATER

M-4

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

EQUIPMENT SCHEDULES - 2

STANDARD 1010.

COOLED WITH AIR COOLED CONDENSER & COMPRESSOR SHALL CONFORM TO ADA/ARI

AND BUILT-IN PRESSURE REGULATOR W/BOTTLE FILLING STATION. MECHANICALLY AIR

WALL MOUNTED TYPE, BUBBLER SHAL BE ACTIVATED BY DEPRESSING EITHER PUSH PADS

ELKAY MODEL LMABF8WS, OR APPROVED EQUAL

MODEL : HALSEY TAYLER HTHB-HACG8SS-NF, OR

POWER : 4.0F.L.AMPS, 115 V, 1 PH, 60 HZ.

CAPACITY : 30.3 LPH, 32.2 DEC C TO 10 DEC C.

VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT REQUIRMENTS.

1. QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR

GENERAL NOTE

W/VIBRATION ISOLATOR

VARIABLE FREQUENCY DRIVE

W/VIBRATION ISOLATOR

VARIABLE FREQUENCY DRIVE

1 W/BACKDRAFT DAMPER 2 W/75 WATT LIGHTING

4 BUILT-IN CONTROL SWITCH.

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

- M5

1 EXISTING AND REMOVAL MECHANICAL PLAN

NOT TO SCALE

FIRST FLOOR

SECOND & THIRD FLOOR

FOURTH FLOOR

C /H

W S

STAIR-3

M-5

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

MECHANICAL PLAN

EXISTING AND REMOVAL

M

G

GAS SYSTEM TO REMAIN

WATER CHILLER TO REMAIN

, GAS SYSTEM AND WATER CHILLER EXCLUDED)

(EXISTING HOT WATER BOILER & DOMESTIC HOT WATER HEATER

EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES.

PROTECTION SPRINKLER SYSTEM, PIPES, INSULATIONS, CONTROL SYSTEM,

SYSTEM, PLUMBING FIXTURES, ELECTRIC WATER COOLERS, AUTOMATIC FIRE

DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER AND VENT PIPING

DRYER VENT, DUCTS, LOUVERS, DIFFUSERS, GRILLES, VALVES, DAMPERS,

AIR SEPARATOR, DOMESTIC HOT WATER STORAGE TANK, RANGE HOOD,

FANS, EXPANSION TANK, AIR CONDITIONING UNITS, UNIT HEATER,

HEATING & VENTILATING UNITS, FAN COIL UNITS, PUMPS, EXHAUST

REMOVE EXISTING DETERIORATED AIR HANDLING UNITS,

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

- M6

SACLE = 1:100

SCALE: 1:100

0 2000 4000

GRAPHIC SCALE

STEEL

STEEL

STEEL

STEEL

MATERIAL

STEEL

FUNCTION

R-1

E-2

E-1

S-3

S-2

S-1

UNIT NO.

PLENUM SLOT DIFFUSER

REGISTER

REGISTER

TYPE

RETURN

TRANSFER

EXHAUST

SUPPLY

SUPPLY

SUPPLY

ACCESSORIESFINISH REMARKS

AIR DEVICE SCHEDULE

2 4

3 5

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/ 114

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/ 118

SLEEPING

LIVING/

MECH ROOM

CORRIDOR

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

CORRIDOR

VEST

STAIR-2 142

COMM

COMM

EWC

STAIR-1

LOBBY

TOILET

STORAGE

STORAGE

VEST

STAIR-3

VEST

ROOM

ISSUE

SLOPE

MUD ROOM

CLOSET

W W WWWW W

LAUNDRY

D D

DD

D D D

DDD

WWWWWW W

VD VD VD VD VDVD VD VDVDVDVDVDVD

VDVD VD

T

T

T TT TT TT TT TT

TTTTTT TT

T

FCU

FAN COIL UNIT

400x300

150x150

800x200

150x100(TYP.)

1,717 CMH

R-1:600x600

150x100(TYP.)

150x100(TYP.)

150x100(TYP.)

800x200

1,717 CMH

R-1:600x600 400x300

150x150

300x250

200x150

300x150

900x300 x

VD

300x250

200x150

300x150

200x150

250x200

300x150

1, x

TV

TV

JAN

TV

550x150

FCU

UNIT

FAN COIL

150x100(TYP.)

EXHAUST DUCT

550x150 550x150 550x150

550x150

550x150200x150

200x150

550x150

550x150

550x150 550x150

EF

(TYP OF 4)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

EF

(TYP OF 4)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

FD FD

400x250

600x500

340 CMH

S-1:200

TV

1, x

T

T

T

1,200x300

EF

EXHAUST FAN

ROOM

PURPOSE

MULTI

250x150

400x100

350x200

300x200

250x150

800x200

FCU

FAN COIL UNIT

1,410 CMH

R-1:750x250

FD

350x150

595 CMH

E-2:350x350

VD

TV

TV

x

400x100

FD

340 CMH

E-2:300x300

350x100

VD VD

VDVD VD VD

FCU

1,717 CMH

R-1:600x600

800x200

250x150

250x150 250x150

250x150

300x200

400x300

250x150

EF

EXHAUST FAN

EF

EXHAUST FAN

(TYPICAL)

ROOM THERMOSTAT

(600 )

EXHAUST DUCT

T T

PARTIAL PLAN SEE DWG

LAUNDRY EXHAUST DUCT

PARTIAL PLAN SEE DWG

MECH. ROOM ENLARGED

220 CMH

S-1:150 x2

50 CMH

S-2:150x100 x11

11x

50 CMH

S-2:150x100 x2

858 CMH

S-1:300 x2

858 CMH

S-1:300

5x

282 CMH

S-1:200 x4

343 CMH

S-1:200

343 CMH

S-3:1,800x2ST

M9

M9

SQUARE DIFFUSER

REGISTER

STEEL 109

EXHAUST OR TRANSFER GRILLE

1 MATCH TO CEILING COLOR INDICATED ARCH. DWG.

2 EQUALIZING DEFLECTOR OR GYPSUM BOARD.

FACE BARS.

7 DOUBLE DEFLECTION REGISTER WITH HORIZONTAL

8 PATTERN CONTROLLER

NECESSARY ACCESSORIES.

AND PROVIDE WITH MANUFACTURER AND ALL

9 EXTERIOR INSULATED PLENUM SUPPLY W/OVAL INTAKE

DOWN BLOW SLOT WIDTH OR APPROVED EQUAL.

TITUS MOD# N-1-D WITH 20mm SLOT & 450mm

5 4-WAY THROW UNLESS OTHERWISE INDICATED

4 OPPOSED BLADE DAMPER

DIA NECK DIA AND SMALLER.

OR GYPSUM BOARD CEILING. USE FOR 175 (7")

FOR SURFACE MOUNTING IN SUSPENDED LAY-IN

NOMINAL FULL FACE 300x300 3-CONE DIFFUSER

AND LARGER.

BOARD CEILING. USE FOR 200 DIA NECK DIA

FOR MOUNTING IN SUSPENDED LAY-IN OR GYPSUM

3 NOMINAL FULL FACE 600x600 3-CONE DIFFUSER

CWS

CWR

NOTE :

DUCTWORK PRIOR TO DUCTWORK INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

M-6

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

1:100

UP

UP

UP

V

SEE DETAIL

M31

WATER CHILLER TO REMAIN

POC

AIR DEVICE SCHEDULE AND NOTE

NEW H.V.A.C PLAN (1ST FLOOR),

NEW H.V.A.C PLAN (1ST FLOOR)

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

- M7

SACLE = 1:100

SCALE: 1:100

0 2000 4000

GRAPHIC SCALE

NOTE :

DUCTWORK PRIOR TO DUCTWORK INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

T

T

T TT TT TT TT TT

TTTTTT TT

T

FCU

FAN COIL UNIT

400x300

150x150

800x200

150x100(TYP.)

1,717 CMH

R-1:600x600

150x100(TYP.)

150x100(TYP.)

150x100(TYP.)

800x200

1,717 CMH

R-1:600x600 400x300

150x150

300x250

200x150

350x150 300x250

200x150

350x150

550x150

FCU

UNIT

FAN COIL

150x100(TYP.)

EXHAUST DUCT

550x150 550x150 550x150550x150 550x150200x150

200x150

550x150

550x150

550x150 550x150

EF

(TYP OF 6)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

EF

(TYP OF 6)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

400x250

600x500

T

EF

EXHAUST FAN

(TYPICAL)

ROOM THERMOSTAT

350x150

595 CMH

E-2:350x350

TT

350x150 350x150

VDVD VD VD

VD

VDVD

VDVD

VD VD VD

x

VD VD VD VD

VD VDVD

VD

VD VD VDVD

U.C

FD

FD

340 CMH

E-1:300x300

FD

FD

150x100

TT

(600 )

EXHAUST DUCT

700x200450x200

FCU

FAN COIL UNIT

2,260 CMH

R-1:500x1,000

1,400x200

CLEANOUT

200x150

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

CORRIDOR

332 232

CORRIDOR

VEST

JAN

COMM

STAIR-1

KITCHEN

LOUNGE 236

STAIR-3

STAIR-3

STORAGE

STORAGE

T T

RH

(2nd FL. ONLY)

RANGE HOOD

550x150

550x150

50 CMH

S-2:150x100 x1313x

50 CMH

S-2:150x100 x2

858 CMH

S-1:300 x2

858 CMH

S-1:300

220 CMH

S-1:150 x2

2x

1,130 CMH

S-2:400X400

1st

FL

OOR

2n d

FL

OOR

3rd F

LO

OR

4th F

LO

OR

DUCT

RIS

ER

x25

EXHAUS

T

AIR

x10

(TY

P.)

- M7

NOT TO SCALE

EXHAUST DUCT ISOMETRIC DIAGRAM

EF

EF

EF

EF

EF

EF

EF

EF

AT

TIC

F

LO

OR

SL

AB

F

IRE

D

AMPE

R

AT

M-7

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

UP

UP

UP

DNDN

DN

AS SHOWN

NEW H.V.A.C PLAN (2ND - 3RD FLOOR)

AND NOTE

& EXHAUST DUCT ISOMETRIC DIAGRAM

NEW H.V.A.C PLAN (2ND - 3RD FLOOR)

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

- M8

SACLE = 1:100

SCALE: 1:100

0 2000 4000

GRAPHIC SCALE

NOTE :

DUCTWORK PRIOR TO DUCTWORK INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

T

T

T TT TT TT TT TT

TTTTTT TT

T

FCU

FAN COIL UNIT

400x300

150x150 800x200

150x100(TYP.)

1,717 CMH

R-1:600x600

150x100(TYP.)

150x100(TYP.)

150x100(TYP.)

800x200

1,717 CMH

R-1:600x600 400x300

200x150

350x150

300x250

200x150

FCU

UNIT

FAN COIL

150x100(TYP.)

EXHAUST DUCT

200x150

200x150

EF

(TYP OF 6)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

EF

(TYP OF 6)

EXHAUST FAN

EF

(TYP OF 7)

EXHAUST FAN

400x250

600x500

T

EF

EXHAUST FAN

(TYPICAL)

ROOM THERMOSTAT

350x150

595 CMH

E-2:350x350

TT

350x150

FD

340 CMH

E-1:300x300

150x100

TT

500x200500x150

FCU

FAN COIL UNIT

CLEANOUT

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

JAN

COMM

STAIR-1

STORAGE

STORAGE

STAIR-3

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

STAIR-3

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

CORRIDOR

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

GAME ROOM

T T

U.C

300x250

350x150

FD

FD

EF

EXHAUST FAN

450x250 250x200

200x150

150x150

1,410 CMH

R-1:750x400

800x200

W/BIRDSCREEN

GOOSENECK

600 EXHAUST AIR

W/BIRDSCREEN

200x200 GOOSENECK

550x150(TYP.)

550x150(TYP.) 550x150(TYP.)

250x150 300x200

250x150 250x150 250x150 250x150

250x150 300x200

250x150 250x150 300x200 250x150

250x150 300x200

TV

TV TV

TVTV

TV

TV

TV

TVTV

TV

TV

TV

TV

TV

TV

TVTV

VD VD

VD VD

VD VD

VD VD

VD VD

VD VD

VD VD VD

FD

FD

TV

VD

VD VD VD

VD VD VD

VD VD

VD VD

VD VD

EF

EXHAUST FAN

EF

EXHAUST FAN

EF

EXHAUST FAN

EF

EXHAUST FAN

50 CMH

S-2:150x100 x13

13x

50 CMH

S-2:150x100

220 CMH

S-1:150 x2

2x

705 CMH

S-2:300X300

2x S-1:300

858 CMH

x2

858 CMH

S-1:300

M-8

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

UP

UP

UP

DNDN

DN

1:100

NEW H.V.A.C PLAN (4TH FLOOR)

AND NOTE

NEW H.V.A.C PLAN (4TH FLOOR)

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

NOTE :

- SACLE = 1:50

M9

LAUNDRY AREA H.V.A.C PARTIAL PLAN

SACLE = 1:50

M9

WALL CAP

400x200

WALL CAP

150x100

TOILET

MUD ROOM

CLOSET

LAUNDRY

TV450x350 700x450

1200x300

CU

(INDOOR UNIT)

AIR CONDITIONING UNIT

CU

CU

(OUDOOR UNIT)

AIR CONDITIONING UNIT

CU

x

400x100 400x100

400x200

150x100

EF

EXHAUST FAN

EF

T

THERMOSTAT

HEATING

(TYPICAL)

ACCESS DOOR

CONNECT TO 2ND FL.

EXHAUST DUCT (600 )

400x250

400x250

750x500 x

550x250

550x250

(TYPICAL)

CLEAN OUT

(TYP.OF 10)

100 EXHAUST DUCT

DAMPER

BACK DRAFT

DAMPER

FIRE

EF

(INDOOR UNIT)

A/C UNIT

3x

2,300 CMH

S-2:400x400

510 CMH

S-1:250 2x

MECH. ROOM DUCT PARTIAL PLAN

W W W W WWW

DDDDD

D D D D D

W W WWWW W

V

SCALE: 1:50

0 1000 2000

GRAPHIC SCALE

M-9

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

AS SHOWN

5. THE EXISTING SMOKE STACKS TO BE REMAINED.

GAS SYSTEM TO BE REMAINED.

AND ALL ASSOCIATED ACCESSORIES, FOR EXTERIOR NATURAL

METER CABINET, VALVE CABINET, FILTER, CHAINLINK FENCE,

4. THE EXISTING GAS METER, REGULATOR, GAS PIPING, GAS

PRIOR TO DUCTWORK INSTALLATION.

3. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK

DIRECTION OF EXISTING ALL PIPING IN FIELD.

2. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND

TEL NO. 010-4175-1111.

INFORMATION OF KYONGDOING IS MR. SHIN, DONG IK /

ACTIONS TO PROTECT THE EXISTING SYSTEM. CONTACT

AUTOMATIC CONTROL SYSTEM AND TAKE ALL NECESSARY

CONSTRUCTION, AND FOLLOW THEIR ADVICE TO BUILD AN

SCHEDULE AND SCOPE OF WORK BEFORE STARTING

THE BOILER & HEATER MANUFACTURER, THE CONSTRUCTION

1. THE CONTRACTOR SHALL INFORM "KYONGDOING NAVIEN",

MECH ROOM

BELOW

OPEN

M

TFR

HT

CT

SD

TFR

M

TFR

M

F.D.

SD

EXHAUST FAN

EF

FD FD

AHU

x

1, x

1,200x300

200x400

DAMPER (TYP.)

O.A. MOTORIZED

HV

FOR MUD ROOM AREA

H.V UNIT

1, x

500x600

500x600

FOR MECH. ROOM VENT.

MOTORIZED DAMPER

300Dx2,700Wx2,300H

AIR PLENUM

INTAKE LOUVER

OUTSIDE AIR

SET AT 12.8°C

COOL. THERMOSTAT

SET AT 20°C

HEAT. THERMOSTAT

ET

EXPANSION TANK

ET

EXPANSION TANK

3,570 CMH

E-1:350x350

INTAKE DUCT OPENING

AND COMBUSTION AIR

O.A INTAKE DUCT OPENING

DETECTOR

SMOKE

M

G

GAS LEAK DETECTION

AUTOMATIC

MAIN GAS PIPING (E)

CHAINLINK FENCE (E)

90mm SHUT OFF

VALVE (E)

SHUT OFF VALVE(E)

CONTROL PANEL(E)

GAS ALARM GONG(E)

FILTER(E)

GAS REGULATOR(E)

GAS METER(E)

SHUT OFF VALVE (E)

G

HV

FOR LAUNDRY AREA

H.V UNIT

WITH CONC. PAD

W/ FACE & BY-PASS DAMPER

FOR MAKE-UP AIR

AIR HANDLING UNIT

HWT

(TYP OF 2)

STORAGE TANK

DOMESTIC HOT WATER

EXISTING HEATER TO REMAIN

EXISTING BOILER TO REMAIN

TO REMAIN

EXISTING GAS PIPING

HP

CP

CIRCULATION PUMP

CHILLED WATER

CIRCULATION PUMP

HOT WATER

TO REMAIN

STS FLUE VENT

P.O.C

REPLACE COMBUSTION AIR INTAKE

PIPE WITH NEW(W/ STS WIRE MESH)

P.O.C

AND NOTE

LAUNDRY AREA H.V.A.C PARTIAL PLAN,

MECH. ROOM DUCT PARTIAL PLAN,

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

SACLE = 1:100

FCU

FCU

(TYPICAL)

FAN COIL UNIT

M10

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

MECH ROOM

BELOW

OPEN

CORRIDOR

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

STAIR-2 142

COMM

COMM

EWC

STAIR-1

LOBBY

TOILET

STORAGE

STORAGE

VEST

STAIR-3

VEST

ROOM

ISSUE

SLOPE

MUD ROOM

CLOSET

W W WWWW W

LAUNDRY

D D

DD

D D D

DDD

WWWWWW W

JAN

ROOM

PURPOSE

MULTI

NOTE :

3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

C /H

W R

C /H

W

RD

C /H

W S

C /H

W S

20 20

C /H

W R

C /H

W S

C /H

W S

D C /H

W R

C/HWS

C /H

W S

C /H

W S

D C /H

W R

D

C /H

W S

C /H

W S

D C /H

W R

C /H

W S

D

C /H

W R

C /H

W S

C /H

W S

C /H

W R

D C /H

W S

C/HWR

C/HWS

D

C /H

W S

C /H

W R

D C /H

W R

C /H

W S

C /H

W R

C /H

W S

D

C /H

W S

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W S

D

C /H

W S

D

C /H

W S

C /H

W S

C/HWS

C /H

W S

C /H

W S

D C /H

W R

C /H

W S

C /H

W

SD

C /H

W R

C /H

W S

C /H

W

SD

C /H

W R

C /H

W S

C /H

W R

C /H

W S

D

C /H

W S

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

SD

C /H

W R

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W S

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FAN COIL UNIT

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FAN COIL UNIT

FCU

FCU

CORRIDOR

(TYPICAL)

PIPE ALIGNMENT GUIDES

(TYPICAL)

PIPE ANCHOR

(TYPICAL)

BELLOWS TYPE

EXPANTION JOINT

PIPING PLAN

SEE PLUMBING

(TYPICAL)

25 DIA DRAIN VALVE

32 32 32 32 32 32 32 32

32 32

25 40 50 50 65 65 80 80 80 80

80 65 65 50 50 40 25

20,20,25

32,25,25

32,32,25

SCALE: 1:100

0 2000 4000

GRAPHIC SCALE

M13PARTIAL PLAN SEE DWG

MECH. ROOM ENLARGED

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF M-10

UP

UP

UP

1:100

V

INSPECTION WHEN THE INSTALLATION OF THE PIPE INSULATION IS COMPLETED.

4. THE CONTRACTOR SHALL INVITE THE MECHANICAL ENGINEER FOR QUALITY

IN ACCORDANCE WITH ASTM E84.

A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED

SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND

3. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND

2. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.

07 00, AND SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.

1. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23

NOTE ON INSTALLATION OF PIPE INSULATION

NEW H.V.A.C PIPING PLAN (1ST FLOOR)

NOTE ON INSTALLATION OF PIPE INSULATION :

FRONT VIEW RIGHT VIEW

50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.

A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF

6. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND SHALL HAVE

5. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.

SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.

4. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23 07 00, AND

INSULATION OR TAPED WITH PVC TAPE TO PREVENT CONDENSATE GENERATION.

RECESSED MOUNTED LED LIGHTING FIXTURES SHOULD BE DOUBLE-WRAPPED WITH

3. THE COOLING, HEATING AND DOMESTIC WATER PIPES CROSSING THE ABOVE CEILING

SADDLE, SHOULD BE AVOIDED ABOVE THE LIGNTING FIXTURES AS MUCH AS POSSIBLE.

2. THE INSTALLATION LOCATION OF THE PIPE HANGER INCLUDDING THE PROTECTION

AS POSSIBLE.

1. THE MECHANICAL PIPES SHOULD NOT PASS ABOVE THE LIGHTING FIXTURES AS MUCH

610 OR 305

LIGHTING FIXTURE (TYP.)

CEILING RECESSED MOUNTED

1,220 OR 610

INSULATION (TYP.)

INSULATION OR PVC TAPE (TYP.)

PIPE (TYP.)

SADDLE (TYP.)

PROTECTION

PVC TAPE (TYP.)

INSULATION OR

(TYP.)

INSULATION

(TYPICAL)

MIN. 150mm

DETAIL OF A PIPE PASSING OVER A LIGHTING FIXTURE LIGHTING FIXTURE AND NOTE

DETAIL OF A PIPE PASSING OVER A

NOTE ON INSTALLATION OF PIPE INSULATION,

NEW H.V.A.C PIPING PLAN (1ST FLOOR),

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

SCALE: 1:100

0 2000 4000

GRAPHIC SCALE

SACLE = 1:100M11

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

CORRIDOR

332 232

CORRIDOR

COMM

STAIR-1

KITCHEN

LOUNGE 236

STAIR-3

STAIR-3

STORAGE

STORAGE

D C /H

W R

C /H

W S

C /H

W S

C /H

W R

C /H

S

D

/H

W S

C /H

W

RD

C /H

W

RD

C /H

W S

C /H

W R

D C /H

W S

C /H

W R

D C /H

W S

C /H

W R

C /H

/H

W R

C /H

W R

C /H

W S

D

C /H

W S

D C /H

W R

D

C /H

W S

D D

C /H

W S

D

C /H

W S

C /H

W R

C /H

W R

C /H

W S

D

C /H

W R

C /H

W R

D C /H

W S

C /H

W R

C /H

W

SD

C /H

W

SD

C /H

W R

D C /H

W S

C /H

W R

C /H

W

SD

C /H

W S

C /H

W

RD

C /H

W S

D C /H

W R

C /H

W S

D C /H

W R

C /H

W R

C /H

W R

C /H

W R

C /H

W S

D

C /H

W

RD

C /H

W S

D

C /H

W S

C /H

W S

D

C /H

W R

C /H

W S

D

C /H

W S

C /H

W R

D

C /H

W R

C /H

W S

C /H

W R

D C /H

W S

C /H

W R

D

C /H

W R

D C /H

W S

C /H

W R

D C /H

W S

D C /H

W S

C /H

W S

C /H

W R

D

FCU

FCU

(TYPICAL)

FAN COIL UNIT

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

VEST

JAN

FCU

FAN COIL UNIT

FCU

FAN COIL UNIT

M-11

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

UP

UP

UP

DNDN

DN

IN ACCORDANCE WITH ASTM E84.

A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED

SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND

NOTE ON INSTALLATION OF PIPE INSULATION

NOTE :

3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

NEW H.V.A.C PIPING PLAN (2ND - 3RD FLOOR)

PIPE INSULATION AND NOTE

FLOOR),NOTE ON INSTALLATION OF

NEW H.V.A.C PIPING PLAN (12ND-3RD

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

0 2000 4000

GRAPHIC SCALE

SACLE = 1:100M12

NOTE :

3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

DETAIL "A"

GATE VALVE

BALANCING VALVE

HWR PIPING

HWR PIPING

15 MANUAL VENT

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

JAN

COMM 428

STAIR-1

STORAGE

STORAGE

STAIR-3

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

STAIR-3

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

CORRIDOR

SLEEPING

LIVING/

SLEEPING

LIVING/

SLEEPING

LIVING/

VEST

GAME ROOM

C /H

W R

C /H

W

SD

C /H

W R

C /H

W R

C /H

W

SD

C /H

W R

C /H

W

RD

C /H

S

/H

W R

C/HWR

C/HWR

D

C /H

W S

C /H

W R

C /H

W R

D

C /H

W S

C /H

W R

C /H

W R

D C /H

W S

C /H

W R

C /H

W R

D C /H

W S

C /H

W R

D

C/HWR

C/HWS

D

C /H

W R

C /H

W S

C /H

W R

C /H

W R

D C /H

W S

C /H

W R

C /H

W R

C /H

W S

C /H

W R

C /H

W

RD

C /H

W R

C /H

W S

D C /H

W R

C /H

W R

D

C /H

W S

C /H

W R

C /H

W R

D

C /H

W S

C/HWR

C/HWR

C /H

W R

C /H

W

SD

C /H

W R

C /H

W R

C /H

W R

C /H

W

SD

C /H

W R

C /H

W S

C /H

W R

D

C /H

W R

C /H

W R

C /H

W

SD

FCU

(TYPICAL)

FAN COIL UNIT

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FAN COIL UNIT

(TYPICAL)

PIPE ANCHOR

(TYPICAL)

AUTO AIR VENT

GUIDES (TYPICAL)

PIPE ALIGNMENT

(TYPICAL)

AUTO AIR VENT

FCU

FAN COIL UNIT

(TYPICAL)

BELLOWS TYPE

EXPANTION JOINT

CORRIDOR

FCU

FCU

32 32 32 25 32 32 32

323232323232

(TYPICAL)

SEE DETAIL "A"

100 100

20,20,25

32 50 50 65

80 80

25,20,20

M-12

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

1:100

UP

UP

UP

DNDN

IN ACCORDANCE WITH ASTM E84.

A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED

SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND

NOTE ON INSTALLATION OF PIPE INSULATION

NEW H.V.A.C PIPING PLAN (4TH FLOOR)

INSULATION OR TAPED WITH PVC TAPE TO PREVENT CONDENSATE GENERATION.

RECESSED MOUNTED LED LIGHTING FIXTURES SHOULD BE DOUBLE-WRAPPED WITH

3. THE COOLING, HEATING AND DOMESTIC WATER PIPES CROSSING THE ABOVE CEILING

SADDLE, SHOULD BE AVOIDED ABOVE THE LIGNTING FIXTURES AS MUCH AS POSSIBLE.

2. THE INSTALLATION LOCATION OF THE PIPE HANGER INCLUDDING THE PROTECTION

AS POSSIBLE.

1. THE MECHANICAL PIPES SHOULD NOT PASS ABOVE THE LIGHTING FIXTURES AS MUCH

610 OR 305

LIGHTING FIXTURE (TYP.)

CEILING RECESSED MOUNTED

1,220 OR 610

INSULATION (TYP.)

INSULATION OR PVC TAPE (TYP.)

PIPE (TYP.)

SADDLE (TYP.)

PROTECTION

PVC TAPE (TYP.)

INSULATION OR

(TYP.)

INSULATION

(TYPICAL)

MIN. 150mm

DETAIL OF A PIPE PASSING OVER A LIGHTING FIXTURE

LIGHTING FIXTURE AND NOTE

DETAIL OF A PIPE PASSING OVER A

NOTE ON INSTALLATION OF PIPE INSULATION,

NEW H.V.A.C PIPING PLAN (4TH FLOOR),

FIRE SPRINKLER SYSTEM

REPAIR BARRACKS S-823 INCLUDING

P.O.C

P.O.C

PREVENTER

BACK-FLOW

REDUCING VALVE

PRESSURE

DRP

RECIRCULATION PUMP

DOMESTIC HOT WATER

HWT

SCALE: 1:50

0 1000 2000

GRAPHIC SCALE

- SACLE = 1:50

M13

M13 SACLE = 1:50

TOILET

MUD ROOM

CLOSET

LAUNDRY

43.3° C

43.3° C

50 FD

50 FD

P-9

P-9

P-10

FOR CONT.

PIPING PLAN

SEE PLUMBING

A

(TYP OF 2)

ARRESTER

WATER HAMMER

B

(TYP OF 2)

WATER HAMMER ARRESTER

A

(TYP OF 2)

ARRESTER

WATER HAMMER

WALL HYDRANT

20 NON-FREEZE TYPE

(TYP OF 14)

STAND PIPE DETAIL

SEE WASHER DRAIN

P-1

P-5b

A

(TYP OF 2)

ARRESTER

WATER HAMMER

B

(TYP OF 2)

ARRESTER

WATER HAMMER

32,32

50,32,20,40

40,100,32,20,40

40,100,32,20,40

50 20

25,15 32

40,100,32,20

40,100,32,20

32,32

20 25

WATER FAUCET (TYP.)

COMBINATION TYPE

15 HOT & COLD WATER

HV

FOR MUD ROOM AREA

H.V UNIT

MECH. ROOM PIPING PARTIAL PLAN

PLUMBING PIPING PARTIAL PLAN

LAUNDRY & MUD ROOM

W W W W WWW

DDDDD

D D D D D

W W WWWW W

V

SUMP PIT

25mm TO

NOTE :

3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

CP

CIRCULATION PUMP

CHILLED WATER

HP

CIRCULATION PUMP

HOT WATER

(TYP OF 2)

CHEMICAL FEEDER

EXPANSION TANK

ET

EXPANSION TANK

ET

60° C

THERMOSTAT (TYP.) 100(E)

(TYP OF 2)

STORAGE TANK

DOMESTIC HOT WATER

AHU

AIR HANDLING UNIT

HV

FOR LAUNDRY AREA

H.V UNIT

(TYP OF 2)

AIR SEPARATOR

AS

DCP

CIRCULATION PUMP

DOMESTIC HOT WATER

EUH

UNIT HEATER

ELECTRIC

UNIT HEATER

UH

SP

SUMP PUMP

SUBMERSIBLE

MAIN PIPE TO REMAIN

DOMESTIC WATER

EXISTING 100mm

A.A.V (TYP.)

BELOW GRADE

VALVE

DRAIN

25mm

HWS

HWR

CWR

CWS

CWS

CWR

C H

W S

HWR

HWS

H W

S

CWR

.3

C

.3

C

.3

C

C

CHWR

100,100,100,25,20,32,40

M-13

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

PLUMBING PIPING PARTIAL PLAN

LAUNDRY & MUD ROOM

MECH. ROOM PIPING PARTIAL PLAN,

1:50

80 FCO

TO REMAIN

WATER CHILLER

(TYPICAL)

CONNECTOR

FLEXIBLE

DRAN PIT

(TYP.)

FLOW SWITCH

BELOW GRADE

POC POC

IN ACCORDANCE WITH ASTM E84.

A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED

SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND

NOTE ON INSTALLATION OF PIPE INSULATION

VENT PIPE TO REMAIN

EXISTING BOILER W/FLUE

FLUE VENT PIPE TO REMAIN

EXISTING DOMESTIC HOT WATER HEATER W/

FOR CONT.

PIPING PLAN

SEE PLUMBING

80 FCOP.O.C

FIRE SPRINKLER…