ACCU AIR COOLED CONDENSING UNIT
ACLD AIR COOLED
ACU AIR CONDITION UNIT (S)
ACV ALARM CHECK VALVE
ADP APPARATUS DEW POINT
AHU AIR HANDLING UNIT
AIR COND AIR CONDITION (-ING,-ED)
AL ALUMINUM
ALT ALTITUDE
AMB AMBIENT
AMP AMPERE(AMP, AMPS)
APPROX APPROXIMATE
AVG AVERAGE
AWG AMERICAN WIRE GAUGE
BARO BAROMETER(-TRIC)
BARO PR PRESSURE, BAROMETRIC
BHP BRAKE HORSEPOWER
BP BOILING POINT
CAP CAPACITY
CCW COUNTER CLOCKWISE
CHW CHILLED WATER
CKT CIRCUIT
CLASS CLASSIFICATION
CLG LOAD COOLING LOAD
COEF COEFFICIENT
CONN CONNECTION
CONT
C
CMH CUBIC METER PER HOUR
CU M CUBIC METER
CENTIGRADE/ CELCIUS
CFCI
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED
CIP CAST IRON PIPE
CWP
CU MM CUBIC MILLIMETER
Cv COEFFICIENT, VALVE FLOW
CW CLOCKWISE OR COLD WATER
CIRCULATING WATER PUMP
DB DECIBEL OR DRY BULB
COMPRESSORCPRSR
DBT DRY BULB TEMPERATURE
DCWS DOMESTIC COLD WATER SUPPLY
DEG or ° DEGREE
DFW DIESEL OIL
DOMESTIC HOT WATER RETURN
DOMESTIC HOT WATER SUPPLY
DHWR
DHWS
DIRECT EXPANSIONDX
DRY PIPE VALVEDPV
DOUBLE POLE DOUBLE THROWDPDT
DEWPOINT TEMPERATUREDPT
DIVISIONDIV
DIFFERENCEDIFF
DIAGRAMDIAG
DIAMETERDIA or
DWG DRAWING
EXPANSION JOINTEXPJT
ENTERING WATER TEMPEWT
EVAPORAT (-E,-ING,-ED,-OR)EVAP
EXTERNAL STATIC PRESSUREESP
EXPLOSION PROOFEP
EQUIPMENTEQPT
ENTERINGENT
EFFICIENCYEFF
EQUIVALENT DIRECT RADIATIONEDR
ECONOMIZERECON
ECCENTRICECC
ENTERING AIR TEMPERATUREEAT
FUEL OILFO
FA FACE AREA OR FRESH AIR
FHC FIRE HOSE CABINET
FHY FIRE HYDRANT
FLA FULL LOAD AMPERES
F FARENHEIT
FLR FLOOR
FEED WATER PUMPFWP
FACE VELOCITYFVEL
FLUSH VALVEFV
FRP
FREQUENCYFREQ
FEMALE PIPE THREADFPT
FIBERGLASS REINFORCED PLASTIC
Ft or ' FEET
FXTR FIXTURE
GALVANIZED STEELGALVS
GAGE OR GAUGEGA
GR GRAMS
GOVERNMENT INSTALLED
GOVERNMENT FURNISHED GFGI
CONTRACTOR INSTALLED
GOVERNMENT FURNISHEDGFCI
GAL GALLONS
GALLONS PER MINUTEGPM
HERTZHZ
HORIZONTALHORIZ
HOT WATER HEATERHWH
HOT WATERHW
HOUR(S)HR
HORSEPOWERHP
MERCURYHG
HEADHD
HB HOSE BIBB
DIAMETER, INSIDEID
ISOMETRICISO
IRON PIPE SIZEIPS
J JOULE
K THERMAL CONDUCTIVITY
K THERMAL CONDUCTIVITY
kG kCAL/HR
KILOGRAM
kG/SQ CM KILOGRAM PER SQ. CENTIMETER kG/SQ CM A
KILOCALORIE PER HOUR
(ABSOLUTE)
KILOGRAM PER SQ. CENTIMETER
kG/SQ CM G
(GAUGE)
KILOGRAM PER SQ. CENTIMETER
kG/SM KILOGRAM PER SQ. METER kG/SM A kG/SM G
(ABSOLUTE)
KILOGRAM PER SQ. METER
KILOGRAM PER SQ. METER (GAGE)
kW KILOWATT kWH KILOWATT HOUR kJ KILOJOULE kPa KILO PASCAL
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LG LENGTH
LH LATENT HEAT
LWT LEAVING WATER TEMPERATURE
LIQUID LINELL
L LITERS
LPD LITERS PER DAY
LPH LITERS PER HOUR
LPS
LM LINEAR METER
LITERS PER SECOND
LAV LAVATORY
LPM LITERS PER MINUTE
LT LAUNDRY TRAY
NUMBERNO
NORMALLY OPENN.O.
NOT IN CONTRACTNIC
NORMALLY CLOSEDN.C.
NOISE CRITERIANC
NCK
MAX
NOT TO SCALENTS
MIN
MPH
M METERS
MAXIMUM
MINIMUM OR MINUTE
METERS PER HOUR
MPS METERS PER SECOND
MM MILLIMETER
NPT NATIONAL TAPER PIPE (THREAD)
NOT APPLICABLEN/A
NECK
MECH MECHANICAL
OS&Y OUTSIDE SCREW & YOKE
OD
OAIL OUTSIDE AIR INTAKE LOUVER
OA OUTSIDE AIR
OUTSIDE DIAMETER
OPNG OPENING
OXY OXYGEN
PERCENT
PRESSURE REDUCING VALVEPRV
PARTS PER MILLIONPPM
POINT OF CONNECTIONPOC
PLUMBINGPLMB
PHASE (ELECTRIC)PH
PRESSURE GAGEPG
PD
POLEP
PRESSURE DROP OR DIFFERENCE
Pa PASCAL
POL PETROLEUM, OIL AND LUBRICANTS
QUANTITYQTY
QUARTQT
REFRIGERATION TONRT
REVOLUTIONS PER MINUTERPM
RADIATORRDTR
RETURN AIRRA
THERMAL RESISTANCER
REFRIGERANT (134A, 22, ETC)R134A,R22
RH RELATIVE HUMIDITY
SUPPLY AIRSA
SYMBOLSYM
SUCTIONSUCT
STORAGESTOR
STEELSTL
STANDARDSTD
STEAMST
SAYBOLT SECONDS UNIVERSALSSU
STAINLESS STEELSST
SAYBOLT SECONDS FUROLSSF
SQUARESQ
SPECIFICATIONSPEC
SINGLE POLE DOUBLE THROWSPDT
SM
LPH, STANDARD CONDITIONSSLPH
LPS, STANDARD CONDITIONSSLPS
SG
SLPD LPD, STANDARD CONDITIONS
SL SENSIBLE LOAD
SH SENSIBLE HEAT
SPECIFIC GRAVITY
SF SAFETY FACTOR
SEC SECOND
SCH SCHEDULE
STATIC PRESSURE
SQUARE METER
SP
SBM
SAN SANITARY
SUBMERSIBLE
TYPICALTYP
THERMOSTATTSTAT
TONS OF REFRIGERATIONTONS
THICKNESSTHK
THERMOMETERTHERM
TEMPERATURETEMP
TEMPERATURE DIFFERENCETD
UNIT HEATERUH
HEAT TRANSFER COEFFICIENTU
WTRPRF
WT
WSHR
WITHW/
WH
WIDTHWD
WCLD
WC
WBT
WB
WATTW
VP
VOL
VISC
VERTICALVERT
VENTILATIONVENT
VELOCITYVEL
VARIABLE AIR VOLUMEVAV
VAC VACUUM
VLV VALVE
V VOLT
WATERPROOF
WEIGHT
WASHER
WATTHOUR OR WATER HEATER
WATER-COOLED
WATER CLOSET
WET BULB TEMPERATURE
WET BULB
PRESSURE, DYNAMIC(VELOCITY)
VOLUME
VISCOSITY
VTR VENT THRU ROOF
UR URINAL
PRESSURE RELIEF
TEMPERATURE
EXPANSION LOOP
EXPANSION JOINT
ANCHOR, INTERMEDIATE
ALIGNMENT GUIDE
AIR VENT, AUTOMATIC
SQUARE HEAD BALANCING COCK
QUICK OPENING
NEEDLE
LOCK SHIELD
FLEXIBLE CONNECTOR
FLOWMETER, ORIFICE
FLOWMETER, VENTURI
FLOW SWITCH
PRESSURE GAUGE AND COCK
STRAINER
THERMOMETER
PRESSURE REDUCING
RELIEF OR SAFETY
SLEEVE
BLOW OFF STRAINER
INLINE PUMP
SAFETY
FLOAT
valves, special duty
GATE, NORMALLY CLOSED
GLOBE
SOLENOID
3 WAY MANUAL
GATE, NORMALLY OPEN
PLUG
MOTOR OPERATED GATE
MOTOR OPERATED GLOBE
3 WAY ELECMOTOR CONTROL
3 WAY AIR MOTOR CONTROLLER
HOSE GATE
HOSE GLOBE
POST INDICATOR
OS Y
ANGLE GLOBE
ANGLE GATE
SWING GATE CHECK
ALARM CHECK
DRY PIPE
DELUGE
PREACTION
TAMPER DETECTION SWITCH
QUICK OPENING DEVICE
NON-RISING STEM
DIAPHRAGM
SOLENOID
MOTOR ELECTRIC
valve actuators
POTABLE COLD WATER
POTABLE HOT WATER
POTABLE HOT WATER RETURN
PIPE SLEEVE
BACKFLOW PREVENTER
PITCH OR PIPE, UP(U), DOWN(D)
VENT THRU ROOF
SURFACE CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN
PIPE SLEEVE WITH FIRE STOPPING
HOSE BIBB
FLOOR SINK (200mm x 200mm)
HOT WATER (60°C)
HOT WATER (82.22°C)
VENT
SANITARY SEWER
COMPRESSED AIR
FUEL OIL SUPPLY
FUEL OIL RETURN
FLOOR DRAIN WITH CLEANOUT
FLOOR DRAIN WITH DEEP TRAP
FLOOR DRAIN WITH NO TRAP
FLOOR DRAIN WITH TRAP TIME
FIRE PROTECTION WATER SUPPLY
MAIN SUPPLY SPRINKLER
WET STANDPIPE
DRY STANDPIPE
COMBINATION STANDPIPE
plumbing sprinkler
82.22°C
60°C
LOW PRESSURE CONDENSATE
BOILER BLOW DOWN
PUMPED CONDENSATE
VACUUM PUMP DISCHARGE
MAKE UP WATER
FUEL OIL DRAIN
FUEL OIL TANK VENT
FUEL OIL GAUGE
FUEL OIL SUPPLY
FUEL OIL RETURN
CONTROL AIR MAIN
DUAL TEMPERATURE RETURN
FILL LINE
MAKE UP WATER
DUAL TEMPERATURE SUPPLY
WATER SUPPLY
LOW TEMPERATURE HOT
WATER RETURN
LOW TEMPERATURE HOT
SPLITTER DAMPER
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
DRAIN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
dampers piping heating air conditioning and refrigeration
DIRECTION OF FLOW
FLEXIBLE CONNECTION
TRANSITION
(810mm WIDTH x 400mm DEPTH)
DUCT SIZES SHOWN
RISE(R), DOWN(D)
CHANGE OF ELEVATION
VERTICAL OR HORIZONTAL
ACCESS DOOR,
FIRST FIGURE IS ON TOP
POSITIVE PRESS.,
OUTSIDE AIR DUCT SECTION,
FIRST FIGURE IS ON TOP
POSITIVE PRESS.,
SUPPLY AIR DUCT SECTION,
FIRST FIGURE IS ON TOP
SECTION, NEGATIVE PRESS.,
RETURN OR EXHAUST AIR DUCT
SUPPLY OR RETURN
FLEXIBLE AIR DUCT,
TRANSITION
SQUARE TO ROUND
REGISTER, CEILING
EXHAUST AIR GRILLE OR
REGISTER, SIDEWALL
SUPPLY AIR GRILLE OR
REGISTER, CEILING
RETURN AIR GRILLE OR
OR REGISTER, CEILING
SUPPLY AIR MODULAR DIFFUSER
DOOR GRILLE (300mmx150mmH)
(500mmWx300mmH, 94.4 LPS)
LOUVER, DOOR OR WALL
(13mm, 47.2 LPS)
DOOR UNDERCUT
duct works grilles, registers and diffusers
CONTINUE / CONTINUATION
fittings
TEE, SINGLE SWEEP
UNION, SCREWED
UNION, FLANGED
CONNECTION, TOP
ELBOW, 90°
ELBOW, TURNED UP
ELBOW, TURNED DOWN
TEE, OUTLET UP
TEE, OUTLET DOWN
CONNECTION, BOTTOM
REDUCER, CONCENTRIC
(STRAIGHT, INVERT)
REDUCER, ECCENTRIC
(STRAIGHT, DOWN)
REDUCER, ECCENTRIC
TEE
ELBOW, 45°
LATERAL
SOLVENT CEMENT
BELL AND SPIGOT
SCREWED
FLANGED
WELDED
SOLDERED/BRAZED
M
NS
BUTTERFLY
BALL
DIAPHRAGM
GATE
INDICATING BUTTERFLY
KEY OPERATED
CHECK
DELUGE VALVE
WALL MOUNTED TEST HEADER
FIRE ALARM BELL
HOSE STATION DRY STANDPIPE
MINI HORN
HORN SPEAKER
WALL HYDRANT 2 HOSE OUTLET
SMOKE DETECTOR
CUTTING POINT
CAP
NON-SPRINKLERED SPACE
RISER
CONNECTION (2-WAY SHOWN)
SIAMESE FIRE DEPARTMENT
CONNECTION
SINGLE FIRE DEPARTMENT
valves
UPRIGHT SPRINKLER (K=5.6)
SIDEWALL SPRINKLER (K=5.6)
UPRIGHT SPRINKLER (K=8.0)
PENDENT SPRINKLER (K=5.6)
PENDENT SPRINKLER (K=8.0)
RESIDENTIAL PENDENT SPRINKLER (K=4.9)
M-1
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
A B B R E V I A T I O N S
MECHANICAL MATERIAL INDICATIONS AND SYMBOLS
FS
VFM
OFM
AVA
S
M
S
M
P
M
M
FD
FCO
SCO
200x200
DSP
WSP
CSP
S
F
PLAN ELEV
S
A
FOS
FOR
RD
RS
RL
D
CWS
CWR
LPC
BBD
PC
VPD
MU
FOD
FOV
FOG
FOS
FOR
HWS
M
HCS
HCR
FILL
MU
HWR
DU 13mm
47.2
94.4
DG
300x150
500/300L
R
AD
FC
SG
SR
RG
RR
810mm x 400mm
810mm x 400mm
810mm x 400mm
EG
ER
810mm x 400mm
LEGEND & ABBREVIATION
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
CAMP CASEYCHONG, ST
260184
FIRE PROTECTION AND MECHANICAL GENERAL NOTES
A. REPAIR/MAINTENANCE (K-WORK)
SCOPE OF WORK
NOTE :
NECESSARY DUCT CONNECTION TO FUNCTION AS ORIGINALLY INTENDED.
NEW PIPING INSTALLATION, REMOVE THE EXIST DUCTWORK AND INSTALL NEW DUCTWORK AND MAKE ALL
DUCTWORK AND PIPING ELEVATION/LOCATION. IF THE EXIST DUCT ELEVATION IS CONFLICTED WITH
9. PRIOR TO INSTALL NEW HVAC AND PLUMBING PIPING CONTRACTOR MUST COORDINATE WITH THE EXIST
NOT BE THE EXACT DUPLICATION OF THE CONTRACT DRAWING.
8. NO MECHANICAL WORK CAN BE STARTED WITHOUT AN APPROVED SHOP DRAWINGS. SHOP DRAWING SHALL
BE VERIFIED AT THE JOB SITE.
7. LOCATION AND SIZES OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. APPROXIMATE AND SHALL
6. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.
CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.
5. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.
4. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.
UL LISTED.
DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE
3. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE
TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.
2. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER
FLEXIBLE DUCTWORK FOR VIBRATION ISOLATION.
1. ALL EQUIPMENT CONNECTIONS TO DUCTWORK SHALL HAVE A MIN. OF 100MM OF REINFORCED CANVAS
LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE U.S. GOVERNMENT.
24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, AND THE
WITHIN 1M OF THE UNIT.
23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH SHUT-OFF VALVE
FLUSHED IS CLEAR AS TAP WATER.
22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL ALL WATER BEING
ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.
PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT. PROVIDE SPIN-IN TYPE FITTINGS AT
21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR USE RADIUS ELBOWS.
BODIES EXPOSED TO AIR BELOW THE FLOOR.
AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION, FROM SINK
20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1/4 INCH PER 1 FOOT. INSULATE ALL SEWER PIPING RECEIVING
PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR CONCEALED CEILINGS.
COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.
AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"x12" ACCESS PANELS FOR TWO VALVES.
ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS
19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS IN DUCTS AT
CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.
18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC PRESSURE
TO THE PROJECT COR FOR GOVERNMENT REVIEW AND APPROVAL.
MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB) REPORT SHALL BE SUBMITTED
APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL SPECIFICATIONS FOR
17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE WITH
CONTRACTING OFFICER FOR APPROAL.
PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL BE
GOVERNMENT.
DETAILS WILL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK AT NO ADDITIONAL COST TO THE U.S.
15. FOR O & MA PROJECTS, KOREA, DECEMBER 30, 2015 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT. THE
14. CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY GOVERNMENT.
OR REPLACED BY THIS CONTRACTOR.
EQUIPMENT, DUCT WORK, PIPING ETC. DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED
13. CONNECT TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE THE EXISTING EQUIPMENT ANY
EQUIPMENT AND ELECTRICAL ITEMS.
THE GOVERNMENT, INCLUDING, BUT NOT NECESSARILY LIMITED TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT NO ADDITIONAL COST TO
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY TO
PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AS DIRECTED BY THE CONTRACTING OFFICER.
11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS
EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO
8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.
7. INSTALL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.
6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.
TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTORS TEST VALVES AND DRAINS.
5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED
FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLIES.
PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,
4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF
PIPES LESS THAN 50 MM (2 INCHES) IN NOMINAL.
OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND
CONFORMING TO ASME/ANSI A13. 1-1996, "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE
3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER (26 FT) INTERVALS, WITH PLASTIC WRAPAROUND TYPE PIPE LABELS
APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.
2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED WITH
APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT SPECIFICATION.
HEADS LOCATIONS WITH, LIGHTING FIXTURES, AND HVAC DEVICES. ALL EQUIPMENT SHALL BE UL LISTED AND/OR FM
CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. CONTRACTOR SHALL COORDINATE SPRINKLER
1. THE EQUIPMENT SHOWN ARE SUGGESTED LOCATIONS HOWEVER FINAL LAYOUT SHALL BE IN ACCORDANCE WITH APPLICABLE
M-2
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
GENERAL NOTES & SCOPE OF WORK
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
CAMP CASEYCHONG, ST
260184
MECHANICAL ROOM. PROVIDE FINAL-AIR LEAKAGE TEST REPORT.
CEILING AND PENETRATORS (DUCT, WATER PIPING, CONDUCT PIPE, FLUE VENT PIPE AND ETC) AT
ROOM. REPAIR INFILTRATION AND SEAL AIR LEAKING PORTIONS INCLUDING CLEARANCE BETWEEN WALL,
8. PRE-AIR LEAKING TEST IS REQUIRED PRIOR TO REPAIR INFILTRATION AND SEALING AT MECHANICAL
ASSOCIATED ACCESSORIES, FOR FIRE PROTECTION SYSTEM AS SHOWN ON DRAWINGS.
7. REPLACE DETERIORATED EXISTING AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM, AND ALL
ON DRAWINGS. (EXISTING DOMESTIC HOT WATER HEATER EXCLUDED)
INSUSLATIONS, CONTROL WORK, EQUIPMENT SUPPORT, AND ALL ASSOCIATED ACCESSORIES AS SHOWN
PLUMBING FIXTURES, ELECTRIC WATER COOLERS, VALVE BOXS FOR WASHING MACHINES, VALVES, PIPES, AND VENT PIPING SYSTEM INCLUDING DOMESTIC HOT WATER STORAGE TANKS, PUMPS, EXPANSION TANK,
6. REPAIR THE PLUMBING SYSTEM BY REPLACING DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER
OPERATIONAL, SUCH AS EQUIPMENTS AND CONTROLS.
5. PERFORM COMMISSIONING AFTER CONSTRUCTION TO VERIFY THAT THE HVAC SYSTEM IS FULLY
4. REPAIR BY REPLACEMENT OF EXISTING DETERIORATED ALL DRYER VENT & CAPS WITH NEW.
CONSTRUCTION TO VERIFY IF THE HVAC SYSTEM WORKS PROPERLY.
3. PERFORM DALT (DUCT AIR LEAKAGE TEST) AND T.A.B (TESTING, ADJUSTING, AND BALANCING) AFTER
SHOWN ON DRAWINGS.
2. PROVIDE NEW ELECTRICAL UNIT HEATER AND CEILING MOUNTED EXHAUST FANS FOR H.V.A.C SYSTEM AS
DRAWINGS. (EXISTING BOILER EXCLUDED)
THERMOSTAT, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON
DIFFUSERS, GRILLES, RANGE HOOD, VALVES, DAMPERS, PIPES, INSULATIONS, CONTROL WORK, ROOM
PUMPS, EXPANSION TANK, AIR SEPARATOR, AIR CONDITIONING UNITS, UNIT HEATER, DUCTS, LOUVERS, DETERIORATED AIR HANDLING UNITS, H.V UNITS, FAN COIL UNITS, EXHAUST FANS, RANGE HOOD,
1. REPAIR THE H.V.A.C (HEATING, COOLING AND VENTILATION) SYSTEM BY REPLACING EXISTING
ITEM NO
AHU
Q'TY SERVICE TYPE
CMH
50.3
HP VOLT/PH/HZ
MOTOR
6.7
ITEM NO Q'TY SERVICE TYPE
509 1,552
FAN COIL UNIT
FLOOR MTD. TYPE
VERTICAL CABINET
NOTEREMARKS
W VOLT/PH/HZ
115/1/60
300 115/1/60
115/1/60
115/1/60
(CMH)
CAPACITY
AIR
4,438
3,981
6,357
2,400
8,140
6,830
11,530
DB WB
COOLING COIL
LPM
(°C)
EWT
(INCH)
MAX WPD
HEATING COIL
4,070
14,890
13,360
22,550
(°C)
EAT
(°C)
EWT
71.0
ITEM NO Q'TY SERVICE TYPE
EF
EF
EF
EF
EF
EF
EF
EXHAUST FANS
REMARKS
1 4
HP VOLT/PH/HZ
115/1/60
FAN MOTOR
208/3/60
115/1/60
1/4 115/1/60
1/4 115/1/60
1/2 115/1/60
1 4
1 2
1 2
1 2 3
RPM
1,080
1,135
1,400
0.25
(INCH)
ESP
0.9
0.25
0.5
DIRECT DRIVEN, CENTRIFUGAL FAN
CEILING MOUNTED,
3 BIRD SCREEN 4 CEILING GRILLE
ITEM NO Q'TY SERVICE TYPE
ET
ET
EXPANSION TANK
BLADDER TYPE
BLADDER TYPE
REMARKS
VOLUME (GAL)
ACCEPTANCE
PRESSURE (PSI)
MAX. WORKING
E Q U I P M E N T S C H E D U L E S - 1
FCU
FCU
FCU
FCU
(mm DIA x mm HEIGHT)
TANK SIZE
600 x 2,030
600 x 1,530
1ST FL. ISSUE ROOM
LIVING/SLEEPING RM
KITCHEN & LOUNGE
2ND & 3RD FL.
MOUNTED CONCEALED TYPE
HORIZONTAL CEILING
MOUNTED CONCEALED TYPE
HORIZONTAL CEILING
MOUNTED CONCEALED TYPE
HORIZONTAL CEILING
W/VIBRATION ISOLATOR
W/VIBRATION ISOLATOR
W/VIBRATION ISOLATOR
(KCAL/HR)
HEAT CAP.
21 71.0
21 71.0
21 71.0
(KCAL/HR)
SENSIBLE
(KCAL/HR)
TOTAL EAT(°C)
19.5
19.5
19.5
19.5
1,650
2,310
DIRECT DRIVEN, CENTRIFUGAL FAN
CEILING MOUNTED,
0.25 700 115/1/60 1 4
FOR 1ST FL. TOILET
EXHAUST AIR FAN
FOR LAUNDRY AREA
EXHAUST AIR FAN
FAN FOR MUD ROOM
CEILING EXHAUST AIR
FOR LOUNGE, GAME RM, JAN
ROOF EXHAUST AIR FAN
FOR BATH ROOMS
ROOF EXHAUST AIR FAN
FOR MECH. RM
WALL EXHAUST AIR FAN
DIRECT DRIVEN, CENTRIFUGAL FAN
IN-LINE DUCT MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL FAN
CEILING MOUNTED,
BELT DRIVEN, CENTRIFUGAL FAN
ROOF MOUNTED,
BELT DRIVEN, CENTRIFUGAL FAN
ROOF MOUNTED,
BELT DRIVEN, CENTRIFUGAL FAN
WALL MOUNTED,
6,800
1,020
1,780
1,330
3,570
0.375
0.375
1,550
1,045
1.0Amp
4.4Amp
(CMH)
CAP.
AIR
3 5
3 5
5 PREFABRICATED ROOF CURB.
ITEM NO
Q'TY SERVICE
TYPE
DRAW-THRU HORIZONTAL
DRAW-THRU HORIZONTAL
CMH
SUPPLY FAN
1,020
30.8
31.5
HP VOLT/PH/HZ
MOTOR
1/2
208/3/60
208/3/60
72,420
REMARKS NOTE
AIR HANDLING UNIT
7,530
(mmAq)
TSP
REMARKS
HEATING COILCOOLING COILSUPPLY FAN
SIZE
FILTER
100%
EAT(°C)
DB WB
32.7
25.5
LAT(°C)
DB WB
17.4
16.2
(°C)
EWT
5.6
(°C)
WTR
212.4
LPM
14.0
(mmAq)
APD
MAX
WPD
MAX
0.92M
MAKE-UP
OUTSIDE AIR
HORIZONTAL
DRAW-THRU
2.5
(M/SEC)
FACE VEL
(KCAL/HR)
TOTAL
107,938
EWT(°C)
71.0
WTR(°C)
5.6
EAT(°C)
LAT(°C)
-15.5
(mmAq)
PD
7.11
AREA
FILTER
1.55SM
O.A
CMH
7,530
PERCENT
HEATING & VENTILATING UNIT
NOTE
COMB. FILTER & MIXING BOX
VIBRATION ISOLATOR W/
W/FACE & BY-PASS DAMPER W/
HV
HV
MUD ROOM
LAUNDRY ROOM 6,800
(mmAq)
TSP
RPM
1,300
743 2
HEATING
(KCAL/HR)
TOTAL
10,863
EAT(°C)
LAT(°C)
-15.5
-15.5
(°C)
EWT
217.6
(LPM)
FLOW RATE
32.6
W/COMBINATION FILTER & MIXING BOX
W/VIBRATION ISOLATOR W/FACE & BY-PASS DAMPER
BY-PASS DAMPER W/FLAT FILTER
W/VIBRATION ISOLATOR W/FACE &
(M/SEC)
FACE VEL
2.5
2.5
AREA
FILTER
0.93SM
0.52SM
3.81
WPD
MAX
0.92M
(mmAq)
APD
MAX
0.92M3.81
SUPPLY FAN
EF
DIRECT DRIVEN, CENTRIFUGAL FAN
CEILING MOUNTED,
0.25 675 115/1/60 1 4
BATH ROOM
JANITOR ROOM 100
4TH FL. GAME RM
MULTI PURPOSE ROOM
ITEM NO Q'TY
AS
AIR SEPARATOR
REMARKS
INLET OUTLET
WATER SYSTEM
HOT/CHILLED
SERVICE TYPE
PIPE MOUNTED
PIPE SIZE
100 DIA 100 DIA WITH STRAINER
LOBBY & CORRIDOR
1ST, 2ND, 3RD & 4RD FL.
208/3/60 x50THK
(6)400x625
128 0.65Amp
0.53Amp
1,830
CHILLED WATER SYSTEM
HOT WATER SYSTEM
M-3
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
EQUIPMENT SCHEDULES - 1
VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT REQUIRMENTS.
1. QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
GENERAL NOTE
1 W/BACKDRAFT DAMPER 2 W/DISCONNECT SWITCH
6. 3 YEARS WARRANTY.
REQUIREMENTS.
5. COIL CAPACITY SHALL BE BASED ON THE COOLING
4. FIBER GLASS FILTER.
PACKAGE AS INDICATED ON DETAIL DWG.
3. EACH UNIT SHALL INCLUDE MANUFACTURER VALVE
2. UNIT SHALL BE PROVIDED WITH SUB-BASE AND COVER.
1. UL & AHRI440 OR KS B 6377 & KC CERTIFIED PRODUCTS.
(KCAL/HR)
TOTAL
71,366
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
2. 3 YEARS WARRANTY.
APPROVED EQUAL.
1. MFR. "LG ELEC" OR
2. 3 YEARS WARRANTY.
1. MFR. "LG ELEC" OR APPROVED EQUAL.
ITEM NO Q'TY SERVICE TYPE
CP
HP
REMARKS
HP VOLT/PH/HZ
208/3/60
FAN MOTOR
208/3/60
115/1/60
RPM
PUMPS
CENTRIFUGAL TYPE
BASE MOUNTED END SUCTION
CENTRIFUGAL TYPE
PIPE MOUNTED IN-LINE
CENTRIFUGAL TYPE
PIPE MOUNTED IN-LINE
(M)
HEAD
1,750
1,750
1,750 1/4
CONSTRUCTION
ALL BRONZE
CONSTRUCTION
ALL BRONZE
ITEM NO Q'TY
ELECTRIC WATER COOLER
E Q U I P M E N T S C H E D U L E S - 2
EWC
DESCRIPTION
ITEM NO Q'TY SERVICE TYPE
REMARKS
VOLT/PH/HZ
ITEM NO Q'TY SERVICE TYPE
RH
REMARKS
1 2 32.5
VOLT/PH/HZ
115/1/60
FAN MOTOR
(CFM)
CAPACITY
FAN
RANGE HOOD
KITCHEN
HOOD VENTED TYPE
STAINLESS STEEL
AMPS
3 CHARCOL AND WASHABLE GREASE FILTER
5,745
(mm)
HOOD SIZE
750 X 500
SP
115/1/601/6
STORAGE TANK SUMP
DOMESTIC HOT WATER
RECIRC. PUMP
DOMESTIC HOT WATER
CIRC. PUMP
DOMESTIC HOT WATER
SUBMERSIBLE SUMP TYPE -
1-1/2
(LPM)
CAP.
ON-OFF DIFF./AL SWITCH
W/BULT-IN AUTOMATIC
ITEM NO Q'TY SERVICE TYPE
REMARKS
(GAL)
CAPACITY
TANK
DOMESTIC HOT WATER STORAGE TANK
HWT
ENTIRE BUILDING
HORIZONTAL TYPE
STEEL ROUND
(mmDIA x mmLONG )
TANK SIZE
1,650 x 3,500
CEMENT-LINED STEEL TANK, 150 PSI.
ASME CODE REQUIREMENTS COMPLETE,
2,000
AIR CONDITIONING UNIT
CU
CU
LAUNDRY ROOM
ONLY SPLIT SYSTEM
DUCT-FREE COOLING
ITEM NO Q'TY SERVICE TYPE
REMARKS
EUH
ELECTRIC UNIT HEATER
MECH. ROOM
DISCHARGE TYPE
HORIZONTAL
(KW)
CAPACITY
HEATING
VOLT/PH/HZ
FAN CAPACITY
LPS
193.5 1,650
RPM HP
1/40 208/1/60
LAUNDRY ROOM
ONLY SPLIT SYSTEM
DUCT-FREE COOLING
5,745
(Kcal/HR)
CAPACITY
TOTAL
CONDENSING UNIT
COMPRESSOR
FLA RLA
12.9 62.5
12.9 62.5
VOLT/PH/HZFLA
0.7
0.7
CONDENSER FAN
208/1/60
208/1/60
208/1/60
208/1/60
EVAPORATOR UNIT(HIGH WALL TYPE)
VOLT/PH/HZCMH
884 1/16
884 1/16
208/1/60
208/1/60
SUPPLY AIR FAN
HP
DX - COOLING COIL
3,855
3,855
EER
10.95
10.95
R-410A
R-410A
REFRGERANT
DB WB
26.7
19.4
(Kcal/HR)
SENSIBLE CAP. EAT(°C)
19.4
26.7
PACKAGE
LOW AMTSIENT
DOWN TO -28°C
DOWN TO -28°C
ITEM NO Q'TY SERVICE TYPE
REMARKS
MECH. ROOM
DISCHARGE TYPE
HORIZONTAL
VOLT/PH/HZ
FAN CAPACITY
CFM
2,290 1,050
RPM HP
1/10
UNIT HEATER
UH
(KCAL/HR)
CAPACITY
HEATING
19,170
DISCONNECT SWITCH & THERMOSTAT
PROVIDE UNIT MOUNTED
LPM
10.0
(°C)
EWT
(°C)
EAT
57.6 71.0 115/1/60
755.5
417.3
127.1
37.9
16.8
7.9
3.9
4.6
3. 3 YEARS WARRTENTY.
2. MFR. "LG ELEC" OR APPROVED EQUAL.
1. EACH UNIT SHALL BE PROVIDED W/ WIRED REMOTE CONTROLLER.
HOT WATER CIRC. PUMP
DRP
DCP
208/3/60
CENTRIFUGAL TYPE
BASE MOUNTED END SUCTION
1,750 5755.5 16.8
CIRC. PUMP
CHILLED WATER
M-4
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
EQUIPMENT SCHEDULES - 2
STANDARD 1010.
COOLED WITH AIR COOLED CONDENSER & COMPRESSOR SHALL CONFORM TO ADA/ARI
AND BUILT-IN PRESSURE REGULATOR W/BOTTLE FILLING STATION. MECHANICALLY AIR
WALL MOUNTED TYPE, BUBBLER SHAL BE ACTIVATED BY DEPRESSING EITHER PUSH PADS
ELKAY MODEL LMABF8WS, OR APPROVED EQUAL
MODEL : HALSEY TAYLER HTHB-HACG8SS-NF, OR
POWER : 4.0F.L.AMPS, 115 V, 1 PH, 60 HZ.
CAPACITY : 30.3 LPH, 32.2 DEC C TO 10 DEC C.
VERIFYING ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT REQUIRMENTS.
1. QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
GENERAL NOTE
W/VIBRATION ISOLATOR
VARIABLE FREQUENCY DRIVE
W/VIBRATION ISOLATOR
VARIABLE FREQUENCY DRIVE
1 W/BACKDRAFT DAMPER 2 W/75 WATT LIGHTING
4 BUILT-IN CONTROL SWITCH.
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
- M5
1 EXISTING AND REMOVAL MECHANICAL PLAN
NOT TO SCALE
FIRST FLOOR
SECOND & THIRD FLOOR
FOURTH FLOOR
C /H
W S
STAIR-3
M-5
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
MECHANICAL PLAN
EXISTING AND REMOVAL
M
G
GAS SYSTEM TO REMAIN
WATER CHILLER TO REMAIN
, GAS SYSTEM AND WATER CHILLER EXCLUDED)
(EXISTING HOT WATER BOILER & DOMESTIC HOT WATER HEATER
EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES.
PROTECTION SPRINKLER SYSTEM, PIPES, INSULATIONS, CONTROL SYSTEM,
SYSTEM, PLUMBING FIXTURES, ELECTRIC WATER COOLERS, AUTOMATIC FIRE
DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER AND VENT PIPING
DRYER VENT, DUCTS, LOUVERS, DIFFUSERS, GRILLES, VALVES, DAMPERS,
AIR SEPARATOR, DOMESTIC HOT WATER STORAGE TANK, RANGE HOOD,
FANS, EXPANSION TANK, AIR CONDITIONING UNITS, UNIT HEATER,
HEATING & VENTILATING UNITS, FAN COIL UNITS, PUMPS, EXHAUST
REMOVE EXISTING DETERIORATED AIR HANDLING UNITS,
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
- M6
SACLE = 1:100
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
STEEL
STEEL
STEEL
STEEL
MATERIAL
STEEL
FUNCTION
R-1
E-2
E-1
S-3
S-2
S-1
UNIT NO.
PLENUM SLOT DIFFUSER
REGISTER
REGISTER
TYPE
RETURN
TRANSFER
EXHAUST
SUPPLY
SUPPLY
SUPPLY
ACCESSORIESFINISH REMARKS
AIR DEVICE SCHEDULE
2 4
3 5
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/ 114
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/ 118
SLEEPING
LIVING/
MECH ROOM
CORRIDOR
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
CORRIDOR
VEST
STAIR-2 142
COMM
COMM
EWC
STAIR-1
LOBBY
TOILET
STORAGE
STORAGE
VEST
STAIR-3
VEST
ROOM
ISSUE
SLOPE
MUD ROOM
CLOSET
W W WWWW W
LAUNDRY
D D
DD
D D D
DDD
WWWWWW W
VD VD VD VD VDVD VD VDVDVDVDVDVD
VDVD VD
T
T
T TT TT TT TT TT
TTTTTT TT
T
FCU
FAN COIL UNIT
400x300
150x150
800x200
150x100(TYP.)
1,717 CMH
R-1:600x600
150x100(TYP.)
150x100(TYP.)
150x100(TYP.)
800x200
1,717 CMH
R-1:600x600 400x300
150x150
300x250
200x150
300x150
900x300 x
VD
300x250
200x150
300x150
200x150
250x200
300x150
1, x
TV
TV
JAN
TV
550x150
FCU
UNIT
FAN COIL
150x100(TYP.)
EXHAUST DUCT
550x150 550x150 550x150
550x150
550x150200x150
200x150
550x150
550x150
550x150 550x150
EF
(TYP OF 4)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
EF
(TYP OF 4)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
FD FD
400x250
600x500
340 CMH
S-1:200
TV
1, x
T
T
T
1,200x300
EF
EXHAUST FAN
ROOM
PURPOSE
MULTI
250x150
400x100
350x200
300x200
250x150
800x200
FCU
FAN COIL UNIT
1,410 CMH
R-1:750x250
FD
350x150
595 CMH
E-2:350x350
VD
TV
TV
x
400x100
FD
340 CMH
E-2:300x300
350x100
VD VD
VDVD VD VD
FCU
1,717 CMH
R-1:600x600
800x200
250x150
250x150 250x150
250x150
300x200
400x300
250x150
EF
EXHAUST FAN
EF
EXHAUST FAN
(TYPICAL)
ROOM THERMOSTAT
(600 )
EXHAUST DUCT
T T
PARTIAL PLAN SEE DWG
LAUNDRY EXHAUST DUCT
PARTIAL PLAN SEE DWG
MECH. ROOM ENLARGED
220 CMH
S-1:150 x2
50 CMH
S-2:150x100 x11
11x
50 CMH
S-2:150x100 x2
858 CMH
S-1:300 x2
858 CMH
S-1:300
5x
282 CMH
S-1:200 x4
343 CMH
S-1:200
343 CMH
S-3:1,800x2ST
M9
M9
SQUARE DIFFUSER
REGISTER
STEEL 109
EXHAUST OR TRANSFER GRILLE
1 MATCH TO CEILING COLOR INDICATED ARCH. DWG.
2 EQUALIZING DEFLECTOR OR GYPSUM BOARD.
FACE BARS.
7 DOUBLE DEFLECTION REGISTER WITH HORIZONTAL
8 PATTERN CONTROLLER
NECESSARY ACCESSORIES.
AND PROVIDE WITH MANUFACTURER AND ALL
9 EXTERIOR INSULATED PLENUM SUPPLY W/OVAL INTAKE
DOWN BLOW SLOT WIDTH OR APPROVED EQUAL.
TITUS MOD# N-1-D WITH 20mm SLOT & 450mm
5 4-WAY THROW UNLESS OTHERWISE INDICATED
4 OPPOSED BLADE DAMPER
DIA NECK DIA AND SMALLER.
OR GYPSUM BOARD CEILING. USE FOR 175 (7")
FOR SURFACE MOUNTING IN SUSPENDED LAY-IN
NOMINAL FULL FACE 300x300 3-CONE DIFFUSER
AND LARGER.
BOARD CEILING. USE FOR 200 DIA NECK DIA
FOR MOUNTING IN SUSPENDED LAY-IN OR GYPSUM
3 NOMINAL FULL FACE 600x600 3-CONE DIFFUSER
CWS
CWR
NOTE :
DUCTWORK PRIOR TO DUCTWORK INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
M-6
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
1:100
UP
UP
UP
V
SEE DETAIL
M31
WATER CHILLER TO REMAIN
POC
AIR DEVICE SCHEDULE AND NOTE
NEW H.V.A.C PLAN (1ST FLOOR),
NEW H.V.A.C PLAN (1ST FLOOR)
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
- M7
SACLE = 1:100
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
NOTE :
DUCTWORK PRIOR TO DUCTWORK INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
T
T
T TT TT TT TT TT
TTTTTT TT
T
FCU
FAN COIL UNIT
400x300
150x150
800x200
150x100(TYP.)
1,717 CMH
R-1:600x600
150x100(TYP.)
150x100(TYP.)
150x100(TYP.)
800x200
1,717 CMH
R-1:600x600 400x300
150x150
300x250
200x150
350x150 300x250
200x150
350x150
550x150
FCU
UNIT
FAN COIL
150x100(TYP.)
EXHAUST DUCT
550x150 550x150 550x150550x150 550x150200x150
200x150
550x150
550x150
550x150 550x150
EF
(TYP OF 6)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
EF
(TYP OF 6)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
400x250
600x500
T
EF
EXHAUST FAN
(TYPICAL)
ROOM THERMOSTAT
350x150
595 CMH
E-2:350x350
TT
350x150 350x150
VDVD VD VD
VD
VDVD
VDVD
VD VD VD
x
VD VD VD VD
VD VDVD
VD
VD VD VDVD
U.C
FD
FD
340 CMH
E-1:300x300
FD
FD
150x100
TT
(600 )
EXHAUST DUCT
700x200450x200
FCU
FAN COIL UNIT
2,260 CMH
R-1:500x1,000
1,400x200
CLEANOUT
200x150
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
CORRIDOR
332 232
CORRIDOR
VEST
JAN
COMM
STAIR-1
KITCHEN
LOUNGE 236
STAIR-3
STAIR-3
STORAGE
STORAGE
T T
RH
(2nd FL. ONLY)
RANGE HOOD
550x150
550x150
50 CMH
S-2:150x100 x1313x
50 CMH
S-2:150x100 x2
858 CMH
S-1:300 x2
858 CMH
S-1:300
220 CMH
S-1:150 x2
2x
1,130 CMH
S-2:400X400
1st
FL
OOR
2n d
FL
OOR
3rd F
LO
OR
4th F
LO
OR
DUCT
RIS
ER
x25
EXHAUS
T
AIR
x10
(TY
P.)
- M7
NOT TO SCALE
EXHAUST DUCT ISOMETRIC DIAGRAM
EF
EF
EF
EF
EF
EF
EF
EF
AT
TIC
F
LO
OR
SL
AB
F
IRE
D
AMPE
R
AT
M-7
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
UP
UP
UP
DNDN
DN
AS SHOWN
NEW H.V.A.C PLAN (2ND - 3RD FLOOR)
AND NOTE
& EXHAUST DUCT ISOMETRIC DIAGRAM
NEW H.V.A.C PLAN (2ND - 3RD FLOOR)
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
- M8
SACLE = 1:100
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
NOTE :
DUCTWORK PRIOR TO DUCTWORK INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
T
T
T TT TT TT TT TT
TTTTTT TT
T
FCU
FAN COIL UNIT
400x300
150x150 800x200
150x100(TYP.)
1,717 CMH
R-1:600x600
150x100(TYP.)
150x100(TYP.)
150x100(TYP.)
800x200
1,717 CMH
R-1:600x600 400x300
200x150
350x150
300x250
200x150
FCU
UNIT
FAN COIL
150x100(TYP.)
EXHAUST DUCT
200x150
200x150
EF
(TYP OF 6)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
EF
(TYP OF 6)
EXHAUST FAN
EF
(TYP OF 7)
EXHAUST FAN
400x250
600x500
T
EF
EXHAUST FAN
(TYPICAL)
ROOM THERMOSTAT
350x150
595 CMH
E-2:350x350
TT
350x150
FD
340 CMH
E-1:300x300
150x100
TT
500x200500x150
FCU
FAN COIL UNIT
CLEANOUT
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
JAN
COMM
STAIR-1
STORAGE
STORAGE
STAIR-3
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
STAIR-3
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
CORRIDOR
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
GAME ROOM
T T
U.C
300x250
350x150
FD
FD
EF
EXHAUST FAN
450x250 250x200
200x150
150x150
1,410 CMH
R-1:750x400
800x200
W/BIRDSCREEN
GOOSENECK
600 EXHAUST AIR
W/BIRDSCREEN
200x200 GOOSENECK
550x150(TYP.)
550x150(TYP.) 550x150(TYP.)
250x150 300x200
250x150 250x150 250x150 250x150
250x150 300x200
250x150 250x150 300x200 250x150
250x150 300x200
TV
TV TV
TVTV
TV
TV
TV
TVTV
TV
TV
TV
TV
TV
TV
TVTV
VD VD
VD VD
VD VD
VD VD
VD VD
VD VD
VD VD VD
FD
FD
TV
VD
VD VD VD
VD VD VD
VD VD
VD VD
VD VD
EF
EXHAUST FAN
EF
EXHAUST FAN
EF
EXHAUST FAN
EF
EXHAUST FAN
50 CMH
S-2:150x100 x13
13x
50 CMH
S-2:150x100
220 CMH
S-1:150 x2
2x
705 CMH
S-2:300X300
2x S-1:300
858 CMH
x2
858 CMH
S-1:300
M-8
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
UP
UP
UP
DNDN
DN
1:100
NEW H.V.A.C PLAN (4TH FLOOR)
AND NOTE
NEW H.V.A.C PLAN (4TH FLOOR)
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
NOTE :
- SACLE = 1:50
M9
LAUNDRY AREA H.V.A.C PARTIAL PLAN
SACLE = 1:50
M9
WALL CAP
400x200
WALL CAP
150x100
TOILET
MUD ROOM
CLOSET
LAUNDRY
TV450x350 700x450
1200x300
CU
(INDOOR UNIT)
AIR CONDITIONING UNIT
CU
CU
(OUDOOR UNIT)
AIR CONDITIONING UNIT
CU
x
400x100 400x100
400x200
150x100
EF
EXHAUST FAN
EF
T
THERMOSTAT
HEATING
(TYPICAL)
ACCESS DOOR
CONNECT TO 2ND FL.
EXHAUST DUCT (600 )
400x250
400x250
750x500 x
550x250
550x250
(TYPICAL)
CLEAN OUT
(TYP.OF 10)
100 EXHAUST DUCT
DAMPER
BACK DRAFT
DAMPER
FIRE
EF
(INDOOR UNIT)
A/C UNIT
3x
2,300 CMH
S-2:400x400
510 CMH
S-1:250 2x
MECH. ROOM DUCT PARTIAL PLAN
W W W W WWW
DDDDD
D D D D D
W W WWWW W
V
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
M-9
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
AS SHOWN
5. THE EXISTING SMOKE STACKS TO BE REMAINED.
GAS SYSTEM TO BE REMAINED.
AND ALL ASSOCIATED ACCESSORIES, FOR EXTERIOR NATURAL
METER CABINET, VALVE CABINET, FILTER, CHAINLINK FENCE,
4. THE EXISTING GAS METER, REGULATOR, GAS PIPING, GAS
PRIOR TO DUCTWORK INSTALLATION.
3. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR DUCTWORK
DIRECTION OF EXISTING ALL PIPING IN FIELD.
2. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
TEL NO. 010-4175-1111.
INFORMATION OF KYONGDOING IS MR. SHIN, DONG IK /
ACTIONS TO PROTECT THE EXISTING SYSTEM. CONTACT
AUTOMATIC CONTROL SYSTEM AND TAKE ALL NECESSARY
CONSTRUCTION, AND FOLLOW THEIR ADVICE TO BUILD AN
SCHEDULE AND SCOPE OF WORK BEFORE STARTING
THE BOILER & HEATER MANUFACTURER, THE CONSTRUCTION
1. THE CONTRACTOR SHALL INFORM "KYONGDOING NAVIEN",
MECH ROOM
BELOW
OPEN
M
TFR
HT
CT
SD
TFR
M
TFR
M
F.D.
SD
EXHAUST FAN
EF
FD FD
AHU
x
1, x
1,200x300
200x400
DAMPER (TYP.)
O.A. MOTORIZED
HV
FOR MUD ROOM AREA
H.V UNIT
1, x
500x600
500x600
FOR MECH. ROOM VENT.
MOTORIZED DAMPER
300Dx2,700Wx2,300H
AIR PLENUM
INTAKE LOUVER
OUTSIDE AIR
SET AT 12.8°C
COOL. THERMOSTAT
SET AT 20°C
HEAT. THERMOSTAT
ET
EXPANSION TANK
ET
EXPANSION TANK
3,570 CMH
E-1:350x350
INTAKE DUCT OPENING
AND COMBUSTION AIR
O.A INTAKE DUCT OPENING
DETECTOR
SMOKE
M
G
GAS LEAK DETECTION
AUTOMATIC
MAIN GAS PIPING (E)
CHAINLINK FENCE (E)
90mm SHUT OFF
VALVE (E)
SHUT OFF VALVE(E)
CONTROL PANEL(E)
GAS ALARM GONG(E)
FILTER(E)
GAS REGULATOR(E)
GAS METER(E)
SHUT OFF VALVE (E)
G
HV
FOR LAUNDRY AREA
H.V UNIT
WITH CONC. PAD
W/ FACE & BY-PASS DAMPER
FOR MAKE-UP AIR
AIR HANDLING UNIT
HWT
(TYP OF 2)
STORAGE TANK
DOMESTIC HOT WATER
EXISTING HEATER TO REMAIN
EXISTING BOILER TO REMAIN
TO REMAIN
EXISTING GAS PIPING
HP
CP
CIRCULATION PUMP
CHILLED WATER
CIRCULATION PUMP
HOT WATER
TO REMAIN
STS FLUE VENT
P.O.C
REPLACE COMBUSTION AIR INTAKE
PIPE WITH NEW(W/ STS WIRE MESH)
P.O.C
AND NOTE
LAUNDRY AREA H.V.A.C PARTIAL PLAN,
MECH. ROOM DUCT PARTIAL PLAN,
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
SACLE = 1:100
FCU
FCU
(TYPICAL)
FAN COIL UNIT
M10
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
MECH ROOM
BELOW
OPEN
CORRIDOR
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
STAIR-2 142
COMM
COMM
EWC
STAIR-1
LOBBY
TOILET
STORAGE
STORAGE
VEST
STAIR-3
VEST
ROOM
ISSUE
SLOPE
MUD ROOM
CLOSET
W W WWWW W
LAUNDRY
D D
DD
D D D
DDD
WWWWWW W
JAN
ROOM
PURPOSE
MULTI
NOTE :
3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
C /H
W R
C /H
W
RD
C /H
W S
C /H
W S
20 20
C /H
W R
C /H
W S
C /H
W S
D C /H
W R
C/HWS
C /H
W S
C /H
W S
D C /H
W R
D
C /H
W S
C /H
W S
D C /H
W R
C /H
W S
D
C /H
W R
C /H
W S
C /H
W S
C /H
W R
D C /H
W S
C/HWR
C/HWS
D
C /H
W S
C /H
W R
D C /H
W R
C /H
W S
C /H
W R
C /H
W S
D
C /H
W S
C /H
W S
D
C /H
W R
C /H
W S
D
C /H
W S
D
C /H
W S
D
C /H
W S
C /H
W S
C/HWS
C /H
W S
C /H
W S
D C /H
W R
C /H
W S
C /H
W
SD
C /H
W R
C /H
W S
C /H
W
SD
C /H
W R
C /H
W S
C /H
W R
C /H
W S
D
C /H
W S
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
SD
C /H
W R
D C /H
W R
C /H
W S
D C /H
W R
C /H
W S
D C /H
W R
C /H
W S
D C /H
W R
C /H
W S
D C /H
W R
C /H
W S
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FAN COIL UNIT
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FAN COIL UNIT
FCU
FCU
CORRIDOR
(TYPICAL)
PIPE ALIGNMENT GUIDES
(TYPICAL)
PIPE ANCHOR
(TYPICAL)
BELLOWS TYPE
EXPANTION JOINT
PIPING PLAN
SEE PLUMBING
(TYPICAL)
25 DIA DRAIN VALVE
32 32 32 32 32 32 32 32
32 32
25 40 50 50 65 65 80 80 80 80
80 65 65 50 50 40 25
20,20,25
32,25,25
32,32,25
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
M13PARTIAL PLAN SEE DWG
MECH. ROOM ENLARGED
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF M-10
UP
UP
UP
1:100
V
INSPECTION WHEN THE INSTALLATION OF THE PIPE INSULATION IS COMPLETED.
4. THE CONTRACTOR SHALL INVITE THE MECHANICAL ENGINEER FOR QUALITY
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
3. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND
2. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.
07 00, AND SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.
1. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23
NOTE ON INSTALLATION OF PIPE INSULATION
NEW H.V.A.C PIPING PLAN (1ST FLOOR)
NOTE ON INSTALLATION OF PIPE INSULATION :
FRONT VIEW RIGHT VIEW
50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.
A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF
6. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND SHALL HAVE
5. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.
SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.
4. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23 07 00, AND
INSULATION OR TAPED WITH PVC TAPE TO PREVENT CONDENSATE GENERATION.
RECESSED MOUNTED LED LIGHTING FIXTURES SHOULD BE DOUBLE-WRAPPED WITH
3. THE COOLING, HEATING AND DOMESTIC WATER PIPES CROSSING THE ABOVE CEILING
SADDLE, SHOULD BE AVOIDED ABOVE THE LIGNTING FIXTURES AS MUCH AS POSSIBLE.
2. THE INSTALLATION LOCATION OF THE PIPE HANGER INCLUDDING THE PROTECTION
AS POSSIBLE.
1. THE MECHANICAL PIPES SHOULD NOT PASS ABOVE THE LIGHTING FIXTURES AS MUCH
610 OR 305
LIGHTING FIXTURE (TYP.)
CEILING RECESSED MOUNTED
1,220 OR 610
INSULATION (TYP.)
INSULATION OR PVC TAPE (TYP.)
PIPE (TYP.)
SADDLE (TYP.)
PROTECTION
PVC TAPE (TYP.)
INSULATION OR
(TYP.)
INSULATION
(TYPICAL)
MIN. 150mm
DETAIL OF A PIPE PASSING OVER A LIGHTING FIXTURE LIGHTING FIXTURE AND NOTE
DETAIL OF A PIPE PASSING OVER A
NOTE ON INSTALLATION OF PIPE INSULATION,
NEW H.V.A.C PIPING PLAN (1ST FLOOR),
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
SCALE: 1:100
0 2000 4000
GRAPHIC SCALE
SACLE = 1:100M11
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
CORRIDOR
332 232
CORRIDOR
COMM
STAIR-1
KITCHEN
LOUNGE 236
STAIR-3
STAIR-3
STORAGE
STORAGE
D C /H
W R
C /H
W S
C /H
W S
C /H
W R
C /H
S
D
/H
W S
C /H
W
RD
C /H
W
RD
C /H
W S
C /H
W R
D C /H
W S
C /H
W R
D C /H
W S
C /H
W R
C /H
/H
W R
C /H
W R
C /H
W S
D
C /H
W S
D C /H
W R
D
C /H
W S
D D
C /H
W S
D
C /H
W S
C /H
W R
C /H
W R
C /H
W S
D
C /H
W R
C /H
W R
D C /H
W S
C /H
W R
C /H
W
SD
C /H
W
SD
C /H
W R
D C /H
W S
C /H
W R
C /H
W
SD
C /H
W S
C /H
W
RD
C /H
W S
D C /H
W R
C /H
W S
D C /H
W R
C /H
W R
C /H
W R
C /H
W R
C /H
W S
D
C /H
W
RD
C /H
W S
D
C /H
W S
C /H
W S
D
C /H
W R
C /H
W S
D
C /H
W S
C /H
W R
D
C /H
W R
C /H
W S
C /H
W R
D C /H
W S
C /H
W R
D
C /H
W R
D C /H
W S
C /H
W R
D C /H
W S
D C /H
W S
C /H
W S
C /H
W R
D
FCU
FCU
(TYPICAL)
FAN COIL UNIT
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
VEST
JAN
FCU
FAN COIL UNIT
FCU
FAN COIL UNIT
M-11
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
UP
UP
UP
DNDN
DN
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
NOTE :
3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
NEW H.V.A.C PIPING PLAN (2ND - 3RD FLOOR)
PIPE INSULATION AND NOTE
FLOOR),NOTE ON INSTALLATION OF
NEW H.V.A.C PIPING PLAN (12ND-3RD
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
0 2000 4000
GRAPHIC SCALE
SACLE = 1:100M12
NOTE :
3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
DETAIL "A"
GATE VALVE
BALANCING VALVE
HWR PIPING
HWR PIPING
15 MANUAL VENT
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
JAN
COMM 428
STAIR-1
STORAGE
STORAGE
STAIR-3
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
STAIR-3
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
CORRIDOR
SLEEPING
LIVING/
SLEEPING
LIVING/
SLEEPING
LIVING/
VEST
GAME ROOM
C /H
W R
C /H
W
SD
C /H
W R
C /H
W R
C /H
W
SD
C /H
W R
C /H
W
RD
C /H
S
/H
W R
C/HWR
C/HWR
D
C /H
W S
C /H
W R
C /H
W R
D
C /H
W S
C /H
W R
C /H
W R
D C /H
W S
C /H
W R
C /H
W R
D C /H
W S
C /H
W R
D
C/HWR
C/HWS
D
C /H
W R
C /H
W S
C /H
W R
C /H
W R
D C /H
W S
C /H
W R
C /H
W R
C /H
W S
C /H
W R
C /H
W
RD
C /H
W R
C /H
W S
D C /H
W R
C /H
W R
D
C /H
W S
C /H
W R
C /H
W R
D
C /H
W S
C/HWR
C/HWR
C /H
W R
C /H
W
SD
C /H
W R
C /H
W R
C /H
W R
C /H
W
SD
C /H
W R
C /H
W S
C /H
W R
D
C /H
W R
C /H
W R
C /H
W
SD
FCU
(TYPICAL)
FAN COIL UNIT
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FAN COIL UNIT
(TYPICAL)
PIPE ANCHOR
(TYPICAL)
AUTO AIR VENT
GUIDES (TYPICAL)
PIPE ALIGNMENT
(TYPICAL)
AUTO AIR VENT
FCU
FAN COIL UNIT
(TYPICAL)
BELLOWS TYPE
EXPANTION JOINT
CORRIDOR
FCU
FCU
32 32 32 25 32 32 32
323232323232
(TYPICAL)
SEE DETAIL "A"
100 100
20,20,25
32 50 50 65
80 80
25,20,20
M-12
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
1:100
UP
UP
UP
DNDN
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
NEW H.V.A.C PIPING PLAN (4TH FLOOR)
INSULATION OR TAPED WITH PVC TAPE TO PREVENT CONDENSATE GENERATION.
RECESSED MOUNTED LED LIGHTING FIXTURES SHOULD BE DOUBLE-WRAPPED WITH
3. THE COOLING, HEATING AND DOMESTIC WATER PIPES CROSSING THE ABOVE CEILING
SADDLE, SHOULD BE AVOIDED ABOVE THE LIGNTING FIXTURES AS MUCH AS POSSIBLE.
2. THE INSTALLATION LOCATION OF THE PIPE HANGER INCLUDDING THE PROTECTION
AS POSSIBLE.
1. THE MECHANICAL PIPES SHOULD NOT PASS ABOVE THE LIGHTING FIXTURES AS MUCH
610 OR 305
LIGHTING FIXTURE (TYP.)
CEILING RECESSED MOUNTED
1,220 OR 610
INSULATION (TYP.)
INSULATION OR PVC TAPE (TYP.)
PIPE (TYP.)
SADDLE (TYP.)
PROTECTION
PVC TAPE (TYP.)
INSULATION OR
(TYP.)
INSULATION
(TYPICAL)
MIN. 150mm
DETAIL OF A PIPE PASSING OVER A LIGHTING FIXTURE
LIGHTING FIXTURE AND NOTE
DETAIL OF A PIPE PASSING OVER A
NOTE ON INSTALLATION OF PIPE INSULATION,
NEW H.V.A.C PIPING PLAN (4TH FLOOR),
FIRE SPRINKLER SYSTEM
REPAIR BARRACKS S-823 INCLUDING
P.O.C
P.O.C
PREVENTER
BACK-FLOW
REDUCING VALVE
PRESSURE
DRP
RECIRCULATION PUMP
DOMESTIC HOT WATER
HWT
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
- SACLE = 1:50
M13
M13 SACLE = 1:50
TOILET
MUD ROOM
CLOSET
LAUNDRY
43.3° C
43.3° C
50 FD
50 FD
P-9
P-9
P-10
FOR CONT.
PIPING PLAN
SEE PLUMBING
A
(TYP OF 2)
ARRESTER
WATER HAMMER
B
(TYP OF 2)
WATER HAMMER ARRESTER
A
(TYP OF 2)
ARRESTER
WATER HAMMER
WALL HYDRANT
20 NON-FREEZE TYPE
(TYP OF 14)
STAND PIPE DETAIL
SEE WASHER DRAIN
P-1
P-5b
A
(TYP OF 2)
ARRESTER
WATER HAMMER
B
(TYP OF 2)
ARRESTER
WATER HAMMER
32,32
50,32,20,40
40,100,32,20,40
40,100,32,20,40
50 20
25,15 32
40,100,32,20
40,100,32,20
32,32
20 25
WATER FAUCET (TYP.)
COMBINATION TYPE
15 HOT & COLD WATER
HV
FOR MUD ROOM AREA
H.V UNIT
MECH. ROOM PIPING PARTIAL PLAN
PLUMBING PIPING PARTIAL PLAN
LAUNDRY & MUD ROOM
W W W W WWW
DDDDD
D D D D D
W W WWWW W
V
SUMP PIT
25mm TO
NOTE :
3. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
CP
CIRCULATION PUMP
CHILLED WATER
HP
CIRCULATION PUMP
HOT WATER
(TYP OF 2)
CHEMICAL FEEDER
EXPANSION TANK
ET
EXPANSION TANK
ET
60° C
THERMOSTAT (TYP.) 100(E)
(TYP OF 2)
STORAGE TANK
DOMESTIC HOT WATER
AHU
AIR HANDLING UNIT
HV
FOR LAUNDRY AREA
H.V UNIT
(TYP OF 2)
AIR SEPARATOR
AS
DCP
CIRCULATION PUMP
DOMESTIC HOT WATER
EUH
UNIT HEATER
ELECTRIC
UNIT HEATER
UH
SP
SUMP PUMP
SUBMERSIBLE
MAIN PIPE TO REMAIN
DOMESTIC WATER
EXISTING 100mm
A.A.V (TYP.)
BELOW GRADE
VALVE
DRAIN
25mm
HWS
HWR
CWR
CWS
CWS
CWR
C H
W S
HWR
HWS
H W
S
CWR
.3
C
.3
C
.3
C
C
CHWR
100,100,100,25,20,32,40
M-13
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
PLUMBING PIPING PARTIAL PLAN
LAUNDRY & MUD ROOM
MECH. ROOM PIPING PARTIAL PLAN,
1:50
80 FCO
TO REMAIN
WATER CHILLER
(TYPICAL)
CONNECTOR
FLEXIBLE
DRAN PIT
(TYP.)
FLOW SWITCH
BELOW GRADE
POC POC
IN ACCORDANCE WITH ASTM E84.
A MAXIMUM SMOKE DEVELOPED INDEX OF 50 WHEN TESTED
SHALL HAVE A MAXIMUM FLAME SPREAD INDEX OF 25 AND
NOTE ON INSTALLATION OF PIPE INSULATION
VENT PIPE TO REMAIN
EXISTING BOILER W/FLUE
FLUE VENT PIPE TO REMAIN
EXISTING DOMESTIC HOT WATER HEATER W/
FOR CONT.
PIPING PLAN
SEE PLUMBING
80 FCOP.O.C
FIRE SPRINKLER…