DRAFT PWS.pdf

PDF 19 KB Posted

Attached to
RFI - URGENT Warping Capstan 3 & 5 Repair Services
Solicitation number
N5701225RC0132C
Issued by

About this file

This Performance Work Statement (PWS) details repair requirements for Warping Capstans 3 and 5 aboard the USS Gerald R. Ford at Naval Station Norfolk. The primary objective is to provide comprehensive troubleshooting, maintenance, and repair services, including all necessary labor, materials, and equipment to ensure the capstans are fully operational. The work involves installing and testing multiple Rockwell Automation PowerFlex components such as inverters, cable frame kits, power interface boards, power supply kits, and associated electrical components, with a specific focus on meeting original equipment manufacturer (OEM) technical specifications.

The contract requires U.S. citizen vendor representatives who will comply with base security directives, obtain appropriate base passes/ID badges, and perform work primarily aboard the ship at Pier 11. The scope includes delivering a written condition report and repair estimate for any equipment requiring repair beyond routine maintenance, and ensuring all capstans are in working order prior to departure. Additional requirements include coordination with the CVN-78 Technical Point of Contact for logistics such as employee badging, naval base access, installation dates, and scheduling deliveries. The procurement will be handled as a commercial item contract with an urgent turnaround timeline.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PERFORMANCE WORK STATEMENT (PWS)

SHORT TITLE: USS Gerald R. Ford - Repair of Warping Capstan 3 and 5

PERFORMANCE WORK STATEMENT

I. DESCRIPTION OF THE SUPPLIES / SERVICES REQUIRED.

A. The USS Gerald R. Ford requires Warping Capstan 3 and 5 trouble shooting and repair assistance as detailed below in this statement of work. All inspection, maintenance, calibration, and testing shall be in accordance with the original equipment manufacturers (OEM) technical specifications and manuals.

B. The Contractor shall provide all labor, materials, and equipment needed in the proper trouble shooting and repair of the Capstan 3 and 5. The contractor shall coordinate with the CVN-78 Technical POC for employee badging, naval base access, installation dates, and scheduling deliveries to the ship.

C. The contractor is responsible for delivery and installation of everything in reference to the Capstan 3 and 5.

D. The contractor shall ensure Capstan 3 and 5 are in working order prior to departure from CVN-78.

E. For any equipment found to require repair beyond periodic maintenance, calibration, and test, the Contractor shall provide a written condition report and a written estimate for repair.

F. Equipment requiring PMI: Warping Capstans 3 and 5

Quantity Rockwell

Automation

Catalog #

SAP Part # Product Description

1 20D-P2-CKE1 n/a Inverter 700S Phase II Control

Cassette*

1 SK-L1-CBL2-F2 PN-D10268 PowerFlex 700L Cable Frame 2 Kit

1 SK-L1-CBL1-F2 PN-D10264 PowerFlex 700L Cable Frame 2 Kit

1 SK-L1-ACC1-F3D 181520-A01 PowerFlex 700L Converter Cassette Kit

1 SK-L1-PIABC1-F2 PN-D10222 PowerFlex 700L Power Interface Board

Kit

1 SK-L1-PIABI1-F2 PN-D10223 PowerFlex 700L Power Interface Board

Kit

1 SK-L1-PWRS1-F2 PN-D10270 PowerFlex 700L Power Supply Kit

PERFORMANCE WORK STATEMENT (PWS)

1 SK-L1-PWRS2-F2 PN-D10271 PowerFlex 700L Power Supply Kit

1 SK-L1-MVF1-C PN-C10531 PowerFlex 700L Voltage Feedback Kit

1 SK-L1-XFMR1-F2 PN-D10274 PowerFlex 700L Transformer Frame 2

Kit

10 FNQ-R-1 FNQ-R-1 Fuse TD CC 600V 1A

5 FNQ-R-2 1/2 FNQ-R-2

1/2

Fuse TD CC 600V 2.5A

1 PN-112613 PN-112613 INTERCOOL NFE-50 GLL (5 gallons) coolant

II. APPLICABLE SHIP(S)/LOCATION OF MAJORITY OF WORK.

Work is to be primarily, but not exclusively, performed aboard the ship, USS Gerald R.

Ford, Naval Station Norfolk, Pier 11.

a. Installation will occur on a U. S. military installation. Vendor representatives and installers shall be U.S. Citizens and shall comply with base security directives and conditions. The contractor is responsible for complying with base security requirements. All base visitors shall obtain a base pass/ID Badge.