DRAFT Price Schedule San Diego Regional.xlsx

XLSX spreadsheet 57 KB Posted

Attached to
Hazardous Waste Disposal San Diego Federal contract opportunity
Solicitation number
24BE178
Issued by
Defense Logistics Agency

About this file

This document is a draft price schedule for a federal contract opportunity related to the transportation and disposal of various hazardous wastes, non-hazardous wastes, batteries, and other materials in the San Diego, California area.

The key details are:

  • The contract opportunity is for a Firm-Fixed Priced, Indefinite Delivery Indefinite Quantity Services Contract with a 30-month base period and a 30-month option period.
  • The scope of work includes the collection, storage, processing, removal, transportation, and final treatment/disposal of hazardous and non-hazardous wastes, as well as special services such as sampling, analysis, industrial cleaning, lab packs/loose packs, and expedited removals.
  • The draft price schedule lists numerous contract line items (CLINs) for various container sizes, rental fees, disposal services, and related activities.
  • The government intends to solicit proposals on SAM.gov and is seeking qualified small businesses, specifically 8(a), HUBZone, woman-owned, and service-disabled veteran-owned small businesses, who can meet the Limitations on Subcontracting requirements.
  • Responses to this sources sought notice are due by 1100 EST on Friday, 20SEP2024.

View the file

Other files for this federal contract opportunity

Other files attached to Hazardous Waste Disposal San Diego, newest first.
File Type Posted
DRAFT PWS San Diego Regional.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Price Schedule

SERVICE

OR BASE

CLINPrice Schedule
San Diego Regional HW Disposal ContractCLINU/MActual

48 mos

(Spec)Est. Qty
BaseEst. Qty
OptionUnit Price
BaseUnit Price
OptionExtended
BaseExtended

Option

1120REDaily rental fee for a 20-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.2).1120REEA9696$ - 0$ - 0$ - 0$ - 0
1121REWeekly rental fee for a 20-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.3).1121REEA33$ - 0$ - 0$ - 0$ - 0
1122REMonthly rental fee for a 20-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.4).1122REEA7575$ - 0$ - 0$ - 0$ - 0
1140REDaily rental fee for a 40-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.2).1140REEA9696$ - 0$ - 0$ - 0$ - 0
1141REWeekly rental fee for a 40-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.3).1141REEA33$ - 0$ - 0$ - 0$ - 0
1142REMonthly rental fee for a 40-yd3 lined rolloff box (ROB) with hard plastic cover (See 3.4).1142REEA7575$ - 0$ - 0$ - 0$ - 0
1200REInitial Placement or Removal of Empty Rented Rolloff Box (ROB) or Vacuum Box. (See 3.10).1200REEA2615656$ - 0$ - 0$ - 0$ - 0
1001SAPerform sampling and analysis to determine Waste Characteristics (D001-D0043) and UHCs using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS). Provide report within 15 business days. (See 3.26).1001SAEA533$ - 0$ - 0$ - 0$ - 0
1901SAPerform sampling and analysis to determine PFAS concentration in Non-Potable Water, EPA SW-846 Method 8327, or updates thereto.1901SAEA22$ - 0$ - 0$ - 0$ - 0
1106SPProvide, 1 GL, poly DR new, OPN, pail w/screw cover, UN 1H2/Y6/S.1106SPEA4545$ - 0$ - 0$ - 0$ - 0Old CLIN 6377AK
1125SPProvide Container, 2.5 gal, UN1H2/Y, open screw top, plastic, with locking lid, New.1125SPEA88$ - 0$ - 0$ - 0$ - 0Old CLIN 6377AJ
1150SPProvide Container, 5 GL, poly DR, new, OPN, pail w/screw top UN 1H2/Y30/S.1150SPEA5252$ - 0$ - 0$ - 0$ - 0Old CLIN 6312C2
1153SPProvide Container, 5 GL, poly DR, new, OPN, pail w/screw top built in turning handle, DUAL UN 1H2/Y1.5/30 AND 1H2/Y30/S, 1EA=25.1153SPEA2727$ - 0$ - 0$ - 0$ - 0Old CLIN 6312C3 = 100 Ea
1158SPProvide Container, 5 GL, poly DR, new, CLO, UN 1H1/Y1.8/100.1158SPEA7575$ - 0$ - 0$ - 0$ - 0Old CLIN 6312C1
1162SPProvide container, 5 GL, Jerrican, poly, rectangular, w/caps, new, UN3H1/Y1.8/100.1162SPEA800800$ - 0$ - 0$ - 0$ - 0Old CLIN 6312C4 = 100Ea. CLIN 6312C5 NOT OFFERED
1166SPProvide, 5 GL, poly DR, new, OPN, pail w/screw top UN 1H2/X125/S.1166SPEA6565$ - 0$ - 0$ - 0$ - 0
1212SPProvide Container, 15 GL, poly DR, new, CLO, UN 1H1/Y1.8/100.1212SPEA5535535$ - 0$ - 0$ - 0$ - 0Old CLIN 6312D2
1220SPProvide Containers, 15 GL, metal DR, new, OPN, DUAL, UN 1A2/Y1.4/100 and 1A2/X187/S, 1 EA=5.1220SPEA77$ - 0$ - 0$ - 0$ - 0Old CLIN 6312D3
1328SPProvide container, 30 GL, poly DR, new, CLO, UN 1H1/Y1.8/100.1328SPEA143143$ - 0$ - 0$ - 0$ - 0Old CLIN 6312PC (1 Ea)
1331SPProvide Containers, 30 GL, poly DR, new, OPN, lever lock ring, UN 1H2/Y180/S, 1EA=25.1331SPEA444$ - 0$ - 0$ - 0$ - 0Old CLIN 6312F8
1334SPProvide Containers, 30 GL, poly DR, new, OPN, lever lock ring, UN 1H2/X120/S.1334SPEA737737$ - 0$ - 0$ - 0$ - 0Old CLIN 6313PR
1345SPProvide Containers, 30 GL, metal DR, new, OPN, DUAL, UN 1A2/Y1.5/150 AND 1A2/X235/S, 1EA=25.1345SPEA33$ - 0$ - 0$ - 0$ - 0Old CLIN 6312MC (1 EA)
1353SPProvide Containers, 30 GL, metal DR, new, CLO, EP lined, UN 1A1/Y1.5/300 1EA=25.1353SPEA44$ - 0$ - 0$ - 0$ - 0Old CLIN 6312F6
1362SPProvide Containers, 30 GL, poly DR, Recon, CLO, UN 1H1/Y1.8/100.1362SPEA4343$ - 0$ - 0$ - 0$ - 0Old CLIN 6312F1
1404SPProvide Containers, 55 GL, poly DR, new, OPN, LLR, UN 1H2/X200/S AND 1H2/Y250/S.1404SPEA1010$ - 0$ - 0$ - 0$ - 0Old CLIN 6312E5
1405SPProvide Containers, 55 GL, poly DR, new, OPN, LLR, UN 1H2/X200/S and 1H2/Y250/S, 1EA=25.1405SPEA86161$ - 0$ - 0$ - 0$ - 0Old CLIN 6311PR (1 EA)
1412SPProvide Containers, 55 GL, metal DR, new, CLO, UN 1A1/X1.8/300, 1EA=25.1412SPEA1010$ - 0$ - 0$ - 0$ - 0Old CLIN 6312GD (1EA=100)
1436SPProvide Containers, 55 GL, poly DR, new, OPN, UN 1H2/Y140/S, 1 EA=5.1436SPEA3535$ - 0$ - 0$ - 0$ - 0
1437SPProvide Containers, Steel Open-Top Drums, 55 GL, New, Unlined, Heavy Bolt Ring, 1 EA=200 Drums, Dual Rated, UN 1A2/Y1.6/150 and 1A2/X400/S.1437SPEA2323$ - 0$ - 0$ - 0$ - 0
1450SPProvide Containers, 55 GL, poly DR, Recon, CLO, UN 1H1/Y1.8/100.1450SPEA7777$ - 0$ - 0$ - 0$ - 0Old CLIN 6312E6
1451SPProvide Containers, 55 GL, poly DR, Recon, CLO, UN 1H1/Y1.8/100, 1EA=25.1451SPEA4040$ - 0$ - 0$ - 0$ - 0Old CLIN6312GE (1 EA=50)
1456SPProvide Containers, 55 GL, Steel DR, Recon, OPN, DUAL, UN 1A2/Y1.2/100 and 1A2/Y 1.4/100, 1 EA=25.1456SPEA26228228$ - 0$ - 0$ - 0$ - 0Old CLIN 6312G3
1469SPProvide Containers, 55 GL, metal DR, Recon, OPN, UN 1A2/Y1.2/100, 1EA=25.1469SPEA3434$ - 0$ - 0$ - 0$ - 0Old CLIN 6312E3
1500SPProvide Containers, 85 GL, metal DR, new, OPN, EP lined, bolt ring, DUAL, UN 1A2T/Y320/S and 1A2/X440/S.1500SPEA333$ - 0$ - 0$ - 0$ - 0Old CLIN 6312H1
1503SPProvide Containers, 85 GL, poly DR, new, OPN, UN1H2/X435/S and UN1H2T/Y320/S.1503SPEA33$ - 0$ - 0$ - 0$ - 0Old CLIN 6312H2
1548SPProvide Containers, 95 GL, poly DR, new, OPN, bolt ring, UN 1H2/X340/S, 1EA=5.1548SPEA111$ - 0$ - 0$ - 0$ - 0Offer as new CLIN
1601SPProvide BAG, 36"x36"x42", flexible bag, UN 13H4/Y, 1EA=25.1601SPEA2424$ - 0$ - 0$ - 0$ - 0Old CLIN 6312K4 (1 EA = 300)
1622SPProvide BOX, 36"x36"x36", cardboard, flap top, UN 11HG/X, 1EA=25.1622SPEA11$ - 0$ - 0$ - 0$ - 0Oldd CLIN 6312K3 (1 Ea= 200
1642SPProvide Containers, 275 GL, tote, poly, new, with pallet, UN 31HA1/Y, 1EA=5.1642SPEA1055$ - 0$ - 0$ - 0$ - 0Old CLIN 6377AM. No Recon offered
1689SPProvide 4ft fiber fluorescent light tube drum, 85 lamp capacity, UN 1G/Y50/S, 1EA=20.1689SPEA22$ - 0$ - 0$ - 0$ - 0Old CLIN 6312M4
1725SPProvide Liner, molded poly, 55 GL, 15 mil, 1EA=20.1725SPEA55$ - 0$ - 0$ - 0$ - 0Old CLIN 6312GC
1002SVIndustrial Cleaning Services (ICS), Daily, Crew of two (2). (See 3.11).1002SVEA222$ - 0$ - 0$ - 0$ - 0
1003SVIndustrial Cleaning Services (ICS), Weekly, Crew of two (2). (See 3.12).1003SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D0011
1007SVIndustrial Cleaning Services (ICS), Daily, Crew of three (3). (See 3.14).1007SVEA133$ - 0$ - 0$ - 0$ - 0
1009SVIndustrial Cleaning Services, Monthly, Crew of Three (3)
(See 3.16).1009SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D0011
1080SVSurcharge for Weekend Work, Daily, Crew of two (2). (See 3.17).1080SVEA111$ - 0$ - 0$ - 0$ - 0
1095SV1-Business Day Expedited Removal/Performance.
(See 1.2.11 & 7.1)1095SVEA222$ - 0$ - 0$ - 0$ - 0
1096SV3-Business Day Expedited Removal/Performance.
(See 1.2.11 & 7.1)1096SVEA922$ - 0$ - 0$ - 0$ - 0
1097SV5-Business Day Expedited Removal/Performance.
(See 1.2.11 & 7.1).1097SVEA71515$ - 0$ - 0$ - 0$ - 0
1095SV1-Business Day Expedited Service/Performance
(See 1.2.11).1095SVEA3522$ - 0$ - 0$ - 0$ - 0
1096SV3-Business Day Expedited Service/Performance
(See 1.2.11).1096SVEA111$ - 0$ - 0$ - 0$ - 0
1097SV5-Business Day Expedited Service/Performance
(See 1.2.11).1097SVEA21313$ - 0$ - 0$ - 0$ - 0
1202SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 5-gal pail. (See 3.27).1202SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D0011
1203SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 15-gal drum.1203SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1204SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 30-gal drum.1204SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1205SVOverpack/Loose Pack smaller container(s) into one Government-provided container up to 55-gal drum.1205SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1206SVOverpack smaller container(s) into one Government-provided container up to 110-gal drum.1206SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1207SVLoose Pack smaller container(s) into one Government-provided CYB or Tri-Wall Box.1207SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1208SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 5-gal pail. (See 3.28).1208SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1209SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 15-gal drum.1209SVEA1011$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1210SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 30-gal drum.1210SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1211SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to 55-gal drum.1211SVEA1011$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
1212SVPrepare/Provide Lab Pack of chemicals into one Contractor-provided container up to CYB or Tri-Wall Box.1212SVEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D001
6379AATransport Government owned rolloff to any base, waste facility or repair facility requested by Generator. One (1) each = eqauls one (1) mile up to 100 miles of travel (1EA = 1 mile) (See 3.10.2).6379AAEA6565$ - 0$ - 0$ - 0$ - 0
650300Provide Certificate of Disposal/Destruction/Recycling. (See 2.1).650300EA388$ - 0$ - 0$ - 0$ - 0
6502RVTransportation of cylinders to ODS reserve, Richmond VA (See 2.5.5).6502RVEA111$ - 0$ - 0$ - 0$ - 0
6610PAPoison Hazard Zone "A" surcharge (See 2.5.4).6610PAEA111$ - 0$ - 0$ - 0$ - 0CLIN not used on 20D0011
BA01Alkaline Batteries, for Contractor's choice of recycling or disposal.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-11.BA01C7LB3694381,45281,452$ - 0$ - 0$ - 0$ - 0
BA03Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal. Physical State: Solid. Permissible Waste Codes: UW, D002, D004-11.BA03C7LB66882882$ - 0$ - 0$ - 0$ - 0
BA04Lead Acid Batteries, Wet, Dry, or Gel Pack. May be managed as UW, HW, or RCRA Exempt under 40 CFR Part 266, Subpart G. For mandatory recycling/recovery.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-11.BA04C7LB48698718,08418,084$ - 0$ - 0$ - 0$ - 0
BA05Lithium Ion (Li-Ion) Batteries, for mandatory recycling.

Physical State: Solid.

Permissible Waste Codes: UW, D001-11.BA05C7LB378462323$ - 0$ - 0$ - 0$ - 0
BA10Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal.

Physical State: Solid.

Permissible Waste Codes: UW, D001-11.BA10C7LB4860532,30332,303$ - 0$ - 0$ - 0$ - 0
BA11Magnesium (Mg) Batteries, for Contractor's choice of recycling or disposal.

Physical State: Solid.

Permissible Waste Codes: UW, D002, D004-11.BA11C7LB756161$ - 0$ - 0$ - 0$ - 0
BA12Mercury (Hg) Batteries, for mandatory recycling.

Physical State: Solid.

Permissible Waste Codes: UW, D002, D004-11.BA12C7LB2622$ - 0$ - 0$ - 0$ - 0
BA13Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-11.BA13C7LB77143,1803,180$ - 0$ - 0$ - 0$ - 0
BA14Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling.

Physical State: Various.

Permissible Waste Codes: UW, D002, D004-11.BA14C7LB1989714,04314,043$ - 0$ - 0$ - 0$ - 0
CS01Permissible Waste Codes: D001, D003-43, Listed. Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid.

Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS01C1EA491111$ - 0$ - 0$ - 0$ - 0
CS01C2EA1733$ - 0$ - 0$ - 0$ - 0
CS01C3EA1344$ - 0$ - 0$ - 0$ - 0
CS01C4EA92323$ - 0$ - 0$ - 0$ - 0
CS03Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid.

Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS03C1EA1577$ - 0$ - 0$ - 0$ - 0
CS03C2EA22$ - 0$ - 0$ - 0$ - 0
CS03C3EA11$ - 0$ - 0$ - 0$ - 0
CS03C4EA111$ - 0$ - 0$ - 0$ - 0
CS05Corrosive Acids, Chromic (H2Cr04 ), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002, D004-11.CS05C1EA611$ - 0$ - 0$ - 0$ - 0
CS05C4EA22$ - 0$ - 0$ - 0$ - 0
CS05C5EA211$ - 0$ - 0$ - 0$ - 0
CS06Corrosive Acids, Chromic (H2Cr04), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002, D004-11.CS06C4EA32626$ - 0$ - 0$ - 0$ - 0
CS06B5EA14,9574,957$ - 0$ - 0$ - 0$ - 0
CS08Corrosive Acids, Non-Fuming, less than 40% Hydrofluoric (HF) and/or less than 25% Nitric (HNO3) in Water.

Physical State: Liquid.

Permissible Waste Codes: D001 (OX), D002, D004-11, Listed Inorganics.CS08C1EA144$ - 0$ - 0$ - 0$ - 0
CS08C4EA15252$ - 0$ - 0$ - 0$ - 0
CS10Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid.

Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS10C1EA5244$ - 0$ - 0$ - 0$ - 0
CS10C2EA1077$ - 0$ - 0$ - 0$ - 0
CS10C3EA1288$ - 0$ - 0$ - 0$ - 0
CS10C4EA8344$ - 0$ - 0$ - 0$ - 0
CS10C5EA111$ - 0$ - 0$ - 0$ - 0
CS12Corrosive Ammonia/Amines, Organic or Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint 140°F or greater.

Physical State: Various.

Permissible Waste Codes: D002, D004-43, Listed.CS12C1EA6922$ - 0$ - 0$ - 0$ - 0
CS12C2EA211$ - 0$ - 0$ - 0$ - 0
CS12C3EA555$ - 0$ - 0$ - 0$ - 0
CS12C4EA96666$ - 0$ - 0$ - 0$ - 0
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint 140°F or greater.

Physical State: Various.

Permissible Waste Codes: D002, D004-43, Listed.CS13C1EA1866$ - 0$ - 0$ - 0$ - 0
CS13C3EA111$ - 0$ - 0$ - 0$ - 0
CS13C4EA422$ - 0$ - 0$ - 0$ - 0
CS14Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

Physical State: Various.

Permissible Waste Codes: D002, D004-11, Listed.CS14C1EA5722$ - 0$ - 0$ - 0$ - 0
CS14C2EA722$ - 0$ - 0$ - 0$ - 0
CS14C3EA5366$ - 0$ - 0$ - 0$ - 0
CS14C4EA582121$ - 0$ - 0$ - 0$ - 0
CY01Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters, and Vessels. Refer to CGC Cross-Reference Table for list of gases. (See 2.5).

Physical State: Compressed Gas(es).

Permissible Waste Codes: As applicable to contained gas or mixed gases.CY01MEEA11744646$ - 0$ - 0$ - 0$ - 0
CY01M1EA16247575$ - 0$ - 0$ - 0$ - 0
CY01M2EA3107777$ - 0$ - 0$ - 0$ - 0
CY01M3EA49244$ - 0$ - 0$ - 0$ - 0
CY02Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters, and Vessels. Refer to CGC Cross-Reference Table for list of gases. (See 2.5).

Physical State: Compressed Gas(es).

Permissible Waste Codes: As applicable to contained gas or mixed gases.CY02MEEA696969$ - 0$ - 0$ - 0$ - 0
CY02M1EA712929$ - 0$ - 0$ - 0$ - 0
CY02M2EA2366$ - 0$ - 0$ - 0$ - 0
CY02M3EA3633$ - 0$ - 0$ - 0$ - 0
CY03Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters, and Vessels. Refer to CGC Cross-Reference Table for list of gases. (See 2.5).

Physical State: Compressed Gas(es).

Permissible Waste Codes: As applicable to contained gas or mixed gases.CY03M1EA22$ - 0$ - 0$ - 0$ - 0
CY03M2EA122$ - 0$ - 0$ - 0$ - 0
CY06Cylinders, Category 6, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56". Physical State: Comp. Gas Permissible Waste Codes: As Appropriate to Each Gas.CY06M2EA122$ - 0$ - 0$ - 0$ - 0
CY09Cylinders, Acetylene, Contains Asbestos, for Purge and Landfill. (See 2.5).

Physical State: Compressed Gas.

Permissible Waste Codes: D001.CY09M1EA133$ - 0$ - 0$ - 0$ - 0
CY09M2EA31414$ - 0$ - 0$ - 0$ - 0
CY09M3EA611$ - 0$ - 0$ - 0$ - 0
CY10Cylinders, Acetylene, No Asbestos, for Recycle/Reuse.

Physical State: Compressed Gas.

Permissible Waste Codes: D001.CY10MEEA911$ - 0$ - 0$ - 0$ - 0
CY10M2EA133$ - 0$ - 0$ - 0$ - 0
CY11Cylinders, Propane, 20-Lb "Grill Size", for Disposal, Recycle, or Reuse. (See 2.5). Typically 13" x 17".

CY11ME = 1 EA Grill-Size Cylinder.

Physical State: Compressed Gas.

Permissible Waste Codes: D001.CY11MEEA491414$ - 0$ - 0$ - 0$ - 0
FL01Aerosols, Flammable/Combustible/Ignitable, Non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various.

Permissible Waste Codes: UW, D001 (IGN), D004-43, Listed.

FL01C7LB15659114,243114,243$ - 0$ - 0$ - 0$ - 0
FL02Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components.

Physical State: Solid.

Permissible Waste Codes: D001, D004-43, Listed.FL02C1EA1111$ - 0$ - 0$ - 0$ - 0
FL02C2EA822$ - 0$ - 0$ - 0$ - 0
FL02C3EA3555$ - 0$ - 0$ - 0$ - 0
FL02C4EA22228383$ - 0$ - 0$ - 0$ - 0
FL02C6EA8311$ - 0$ - 0$ - 0$ - 0
FL03Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris. Primarily consists of incinerable, non-fuels-blendable materials. No isocyanates (See FL16). Use LP03 for loose packs.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.FL03C1EA5853535$ - 0$ - 0$ - 0$ - 0
FL03C2EA68120120$ - 0$ - 0$ - 0$ - 0
FL03C3EA2489696$ - 0$ - 0$ - 0$ - 0
FL03C4EA12922,1742,174$ - 0$ - 0$ - 0$ - 0
FL03C6EA29197197$ - 0$ - 0$ - 0$ - 0
FL04Flammable Corrosive Liquids/Solids/Sludges/Debris/ Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various.

Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-43, Listed.FL04C1EA12311$ - 0$ - 0$ - 0$ - 0
FL04C3EA511$ - 0$ - 0$ - 0$ - 0
FL04C4EA888$ - 0$ - 0$ - 0$ - 0
FL05Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb., <5% total chlorine, no isocyanates.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL05C1EA1081010$ - 0$ - 0$ - 0$ - 0
FL05C2EA11125125$ - 0$ - 0$ - 0$ - 0
FL05C3EA1641010$ - 0$ - 0$ - 0$ - 0
FL05C4EA5021,2301,230$ - 0$ - 0$ - 0$ - 0
FL05C5EA122$ - 0$ - 0$ - 0$ - 0
FL05C6EA41515$ - 0$ - 0$ - 0$ - 0
FL06Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb., <5% total chlorine, no isocyanates.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL06C1EA12411$ - 0$ - 0$ - 0$ - 0
FL06C2EA1622$ - 0$ - 0$ - 0$ - 0
FL06C4EA74145145$ - 0$ - 0$ - 0$ - 0
FL07Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL07C3EA1222$ - 0$ - 0$ - 0$ - 0
FL07C34EA11111$ - 0$ - 0$ - 0$ - 0
FL07C5EA1711$ - 0$ - 0$ - 0$ - 0
FL08Flammable Resuspendable Solids/Sludges, Fuels Blendable, Rich, >7,000 BTU/Lb., <5% total chlorine, no isocyanates.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL08C1EAFL08C611$ - 0$ - 0$ - 0$ - 0
FL08C5EA223223$ - 0$ - 0$ - 0$ - 0
FL09Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb., <5% total chlorine, no isocyanates.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL09C4EA122$ - 0$ - 0$ - 0$ - 0
FL11Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.

Physical State: Liquid.

Permissible Waste Codes: D001 (IGN), D004-43, Listed, UW (Pesticides Only).FL11C2EA3111$ - 0$ - 0$ - 0$ - 0
FL13Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives).

Physical State: Various.

Permissible Waste Codes: D001(OX), D002, D004-43, Listed.FL13C1EA44$ - 0$ - 0$ - 0$ - 0
FL13C3EA22$ - 0$ - 0$ - 0$ - 0
FL13C4EA107107$ - 0$ - 0$ - 0$ - 0
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.FL99C7LB50557557$ - 0$ - 0$ - 0$ - 0
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various.

Permissible Waste Codes: D002, D004-11, Listed.LP01C1EA2743333$ - 0$ - 0$ - 0$ - 0
LP01C2EA291717$ - 0$ - 0$ - 0$ - 0
LP01C3EA644242$ - 0$ - 0$ - 0$ - 0
LP01C4EA239797$ - 0$ - 0$ - 0$ - 0
LP02Lab Packs/Loose Packs, Mercury, Metallic/Elemental Liquid, for mandatory recycling in U.S. Do not export.

Physical State: Various.

Permissible Waste Codes: D004-11, Listed Inorganics.LP02C1EA11$ - 0$ - 0$ - 0$ - 0
LP02C2EA411$ - 0$ - 0$ - 0$ - 0
LP03Lab Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14. No isocyanates (See LP16).

Physical State: Various.

Permissible Waste Codes: D001-2, D004-43, Listed Flammables.LP03C1EA4062323$ - 0$ - 0$ - 0$ - 0
LP03C2EA463737$ - 0$ - 0$ - 0$ - 0
LP03C3EA634343$ - 0$ - 0$ - 0$ - 0
LP03C4EA230337337$ - 0$ - 0$ - 0$ - 0
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals.

Physical State: Various.

Permissible Waste Codes: N/A.LP04C1EA4586363$ - 0$ - 0$ - 0$ - 0
LP04C2EA966363$ - 0$ - 0$ - 0$ - 0
LP04C3EA113109109$ - 0$ - 0$ - 0$ - 0
LP04C4EA169685685$ - 0$ - 0$ - 0$ - 0
LP04C6EA18133133$ - 0$ - 0$ - 0$ - 0
LP05Lab Packs/Loose Packs, Non-Reactive Oxidizers.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002, D004-43, Listed.LP05C1EA311010$ - 0$ - 0$ - 0$ - 0
LP05C2EA333$ - 0$ - 0$ - 0$ - 0
LP05C3EA199$ - 0$ - 0$ - 0$ - 0
LP05C4EA11212$ - 0$ - 0$ - 0$ - 0
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Generators Special packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D002-43, Listed.LP06C1EA1555$ - 0$ - 0$ - 0$ - 0
LP06C3EA211$ - 0$ - 0$ - 0$ - 0
LP06C4EA244$ - 0$ - 0$ - 0$ - 0
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Generator special packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-43, Listed.LP07C2EA688$ - 0$ - 0$ - 0$ - 0
LP08Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Generator special packaging may be required.

Physical State: Various.

Permissible Waste Codes: D001-43, Listed.LP08C1EA222$ - 0$ - 0$ - 0$ - 0
LP08C2EA33$ - 0$ - 0$ - 0$ - 0
LP08C3EA111$ - 0$ - 0$ - 0$ - 0
LP09Lab Packs/Loose Packs, Toxic Metals.

Physical State: Various.

Permissible Waste Codes: D004-11, Listed Inorganic.LP09C1EA1844$ - 0$ - 0$ - 0$ - 0
LP09C2EA177$ - 0$ - 0$ - 0$ - 0
LP09C3EA199$ - 0$ - 0$ - 0$ - 0
LP09C4EA1919$ - 0$ - 0$ - 0$ - 0
LP09C6EA7377$ - 0$ - 0$ - 0$ - 0
LP10Lab Packs/Loose Packs, Toxic Organics.

Physical State: Various.

Permissible Waste Codes: D004-43, Listed.LP10C1EA2122$ - 0$ - 0$ - 0$ - 0
LP10C2EA11212$ - 0$ - 0$ - 0$ - 0
LP10C3EA32222$ - 0$ - 0$ - 0$ - 0
LP10C4EA611$ - 0$ - 0$ - 0$ - 0
LP11Lab Packs/Loose Packs, Toxic, P-Listed, acutely hazardous, including pharmaceuticals, for mandatory RCRA incineration. May be packaged with U-Listed waste. Special Generator turn-in requirements may apply.

Physical State: Various.

Permissible Waste Codes: D004-43, P- and U-Listed.LP11C1EA4933$ - 0$ - 0$ - 0$ - 0
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration. Special Generator turn-in requirements may apply.

Physical State: Various.

Permissible Waste Codes: D004-43, U-Listed.LP12C1EA4577$ - 0$ - 0$ - 0$ - 0
LP12C2EA122$ - 0$ - 0$ - 0$ - 0
LP12C3EA111$ - 0$ - 0$ - 0$ - 0
LP12C4EA188$ - 0$ - 0$ - 0$ - 0
LP14Loose-Packed Paints and Paint-Related Materials, Oil/Petroleum-Based, >7,000 BTU/Lb. May contain some non-deliberate incidental water-based paints. Formerly CLIN FL14. No Isocyanates (See LP16).

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.LP14C1EA4555$ - 0$ - 0$ - 0$ - 0
LP14C4EA11,1691,169$ - 0$ - 0$ - 0$ - 0
LP14C5EA111$ - 0$ - 0$ - 0$ - 0
LP14C6EA18282$ - 0$ - 0$ - 0$ - 0
LP15Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06.

Physical State: Various.

Permissible Waste Codes: N/A.LP15C1EA1811$ - 0$ - 0$ - 0$ - 0
LP15C2EA166$ - 0$ - 0$ - 0$ - 0
LP15C3EA144$ - 0$ - 0$ - 0$ - 0
LP15C4EA5252$ - 0$ - 0$ - 0$ - 0
LP15C6EA7377$ - 0$ - 0$ - 0$ - 0
LP16Loose-Packed Paints. Non-Reactive paints and other coatings listing isocyanates in the ingredients.

Physical State: Various.

Permissible Waste Codes: D001 (IGN), D004-43, Listed.LP16C1EA1811$ - 0$ - 0$ - 0$ - 0
LP16C2EA111$ - 0$ - 0$ - 0$ - 0
LP16C3EA111$ - 0$ - 0$ - 0$ - 0
LP16C4EA232232$ - 0$ - 0$ - 0$ - 0
LP16C6EA7377$ - 0$ - 0$ - 0$ - 0
NR01Non-RCRA Solids/Debris for direct disposal at a RCRA Subtitle D or Subtitle C landfill. Passes paint filter test. May include drained/dry non-PCB-related equipment. No asbestos. No AFFF-related PFAS.

Physical State: Solid.

Permissible Waste Codes: N/A.NR01C1EA23333$ - 0$ - 0$ - 0$ - 0
NR01C2EA563737$ - 0$ - 0$ - 0$ - 0
NR01C3EA2557777$ - 0$ - 0$ - 0$ - 0
NR01C4EA5543297297$ - 0$ - 0$ - 0$ - 0
NR01C6EA737401401$ - 0$ - 0$ - 0$ - 0
NR01B1LB220082,18782,187$ - 0$ - 0$ - 0$ - 0
NR01B2LB130260229,004229,004$ - 0$ - 0$ - 0$ - 0
NR01B3LB92710325,063325,063$ - 0$ - 0$ - 0$ - 0
NR01B4LB53150209,348209,348$ - 0$ - 0$ - 0$ - 0
NR01B6CD894490490$ - 0$ - 0$ - 0$ - 0
NR02Non-RCRA Solids/Debris with Asbestos for direct disposal at a TSCA/RCRA Subtitle D or Subtitle C landfill. Passes paint filter test. Special packaging may be required.

Physical State: Solid.

Permissible Waste Codes: N/A.NR02C1EA122$ - 0$ - 0$ - 0$ - 0
NR02C2EA11$ - 0$ - 0$ - 0$ - 0
NR02C3EA2722$ - 0$ - 0$ - 0$ - 0
NR02C4EA5533$ - 0$ - 0$ - 0$ - 0
NR02C6EA82727$ - 0$ - 0$ - 0$ - 0
NR03Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR03B5GL2092377,6347,634$ - 0$ - 0$ - 0$ - 0
NR03C1EA2663232$ - 0$ - 0$ - 0$ - 0
NR03C2EA233939$ - 0$ - 0$ - 0$ - 0
NR03C3EA1392424$ - 0$ - 0$ - 0$ - 0
NR03C4EA773983983$ - 0$ - 0$ - 0$ - 0
NR03C5EA122$ - 0$ - 0$ - 0$ - 0
NR04Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR04C1EA2154343$ - 0$ - 0$ - 0$ - 0
NR04C2EA111717$ - 0$ - 0$ - 0$ - 0
NR04C3EA4155$ - 0$ - 0$ - 0$ - 0
NR04C4EA418915915$ - 0$ - 0$ - 0$ - 0
NR04C5EA633$ - 0$ - 0$ - 0$ - 0
NR05Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D or Subtitle C landfill. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment, per Section 3.29.

Physical State: Various.

Permissible Waste Codes: N/A.NR05C1GL6779333$ - 0$ - 0$ - 0$ - 0
NR05C2EA19832832$ - 0$ - 0$ - 0$ - 0
NR05C3EA371515$ - 0$ - 0$ - 0$ - 0
NR05C4EA2163,0743,074$ - 0$ - 0$ - 0$ - 0
NR12Non-RCRA Liquids for RCRA Incineration, pumpable. Not used for AFFF or other PFAS-related wastes. CD required.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR12C4EA2390390$ - 0$ - 0$ - 0$ - 0
NR96C5EA655$ - 0$ - 0$ - 0$ - 0
PC10PCB Solids/Debris Contaminated with at least 50 ppm Source, e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD or Cert of Recycling required. (See 2.3).

Physical State: Solid.

Permissible Waste Codes: N/A.PC10C7LB31682,7332,733$ - 0$ - 0$ - 0$ - 0
PF01AFFF and other PFAS-related Liquids/Waters, Non-RCRA, <1.0 ppm PFAS, for treatment and disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. Certificate of Disposal required. See 2.4.PF01B5GL240085,00685,006$ - 0$ - 0$ - 0$ - 0
PF01C1EA22$ - 0$ - 0$ - 0$ - 0
PF01C4EA16184184$ - 0$ - 0$ - 0$ - 0
PF01T2EA413737$ - 0$ - 0$ - 0$ - 0
PF02AFFF and other PFAS-related Liquids/Waters, Non-RCRA, 1-100 ppm PFAS, for treatment and disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. Certificate of Disposal required. See 2.4.PF02B5GL24001,3041,304$ - 0$ - 0$ - 0$ - 0
PF02C1EA111$ - 0$ - 0$ - 0$ - 0
PF02C4EA511$ - 0$ - 0$ - 0$ - 0
PF02T2EA211$ - 0$ - 0$ - 0$ - 0
PF02T3EA111$ - 0$ - 0$ - 0$ - 0
PF03AFFF and other PFAS-related Liquids/Waters, Non-RCRA, >100 ppm PFAS, for treatment and disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates & Concentrates. Certificate of Disposal required. See 2.4.PF03B5GL24001,6341,634$ - 0$ - 0$ - 0$ - 0
PF03C4EA46184184$ - 0$ - 0$ - 0$ - 0
PF03T2EA23737$ - 0$ - 0$ - 0$ - 0
PF04AFFF and other PFAS-related Solids/Debris, Non-RCRA, <1.0 ppm PFAS, for direct disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. Passes Paint Filter Test. No Cylinders. Certificate of Disposal required. See 2.4.PF04C1EA240011$ - 0$ - 0$ - 0$ - 0
PF04C4EA4611$ - 0$ - 0$ - 0$ - 0
PF04C6EA233$ - 0$ - 0$ - 0$ - 0
PF05AFFF and other PFAS-related Solids/Debris, Non-RCRA, >100 ppm PFAS, for direct disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. Passes Paint Filter Test. No Cylinders. Certificate of Disposal required. See 2.4.PF05C4EA13131$ - 0$ - 0$ - 0$ - 0
PF05C6EA761111$ - 0$ - 0$ - 0$ - 0
PF09AFFF and other PFAS-related Solids/Sludges/Debris with Free Liquids, Non-RCRA, >100 ppm PFAS, for treatment and disposal at a RCRA Subtitle C Landfill specifically designated as authorized for PFAS disposal in the QFL. No Cylinders. Certificate of Disposal required. See 2.4.PF09C1EA111$ - 0$ - 0$ - 0$ - 0
PF09C2EA111$ - 0$ - 0$ - 0$ - 0
PF09C3EA111$ - 0$ - 0$ - 0$ - 0
PF09C4EA611$ - 0$ - 0$ - 0$ - 0
RE01Lamps, Fluorescent, Intact. Includes CFLs, U-Bent, Circulars.

Physical State: Solid.

Permissible Waste Codes: UW, D004-11.RE01C7LB1811881,1701,170$ - 0$ - 0$ - 0$ - 0
RE02Lamps, Fluorescent, Crushed/Broken, may contain filters.

Physical State: Solid.

Permissible Waste Codes: UW, D004-11.RE02C1LB11$ - 0$ - 0$ - 0$ - 0
RE02C4EA3366$ - 0$ - 0$ - 0$ - 0
RE04Lamps, High Intensity Discharge (HID) and/or Light Emitting Diode (LED).

Physical State: Solid.

Permissible Waste Codes: UW, D004-11.RE04C7LB652310310$ - 0$ - 0$ - 0$ - 0
RE06Lamps, Metal Halide and Metal Hydride, including Sodium.

Physical State: Solid.

Permissible Waste Codes: Universal Waste D003-11.RE06C7LB5998507507$ - 0$ - 0$ - 0$ - 0
RE08Mercury, High, Dental Amalgams, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various.

Permissible Waste Codes: UW, D004-11.RE08C1EA5722$ - 0$ - 0$ - 0$ - 0
RE08C2EA1033$ - 0$ - 0$ - 0$ - 0
RE09Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various.

Permissible Waste Codes: UW, D004-11.RE09C1EA2677$ - 0$ - 0$ - 0$ - 0
RE09C2EA211$ - 0$ - 0$ - 0$ - 0
RE10Antifreeze, Used and Unused for (Recycling or Fuels Blending). Note: RE10ME refers to 55-gal drums (Min: 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator.

Physical State: Liquid.

Permissible Waste Codes: UW, D004-11.RE10C1EA11$ - 0$ - 0$ - 0$ - 0
RE10C3EA240033$ - 0$ - 0$ - 0$ - 0
RE10C4EA32114114$ - 0$ - 0$ - 0$ - 0
RE10B5EA11$ - 0$ - 0$ - 0$ - 0
RE10MEEA4912828$ - 0$ - 0$ - 0$ - 0
RE11Used Oil, <10% Water, <1,000 ppm Total Organic Halides. RE11ME refers to 55-gal containers pumped/vacuumed/stung onsite and includes recycling and service. To use RE11ME, a minimum quantity of 30 drums must be pumped per location per task order. 1 EA of RE10ME equals 1 drum.

Physical State: Liquid

Permissible Waste Codes: UW in some states.RE11C1EA11$ - 0$ - 0$ - 0$ - 0
RE11C4EA36503838$ - 0$ - 0$ - 0$ - 0
RE11MEEA81,8721,872$ - 0$ - 0$ - 0$ - 0
RE12Used Oil, >10% Water, <1,000 ppm total organic halides (TOX) for energy recovery, recycling, fuels blending.

Physical State: Liquid.

Permissible Waste Codes: UW, D004-11.RE12C3EA249122$ - 0$ - 0$ - 0$ - 0
RE12C4EA1184184$ - 0$ - 0$ - 0$ - 0
RE77Used Oil Filters, Metal only, California UW for recycling, punctured and properly drained per CA DTSC guidelines. Physical State: Solid Permissible Waste Codes: UW (CA only).RE13C4EA3544$ - 0$ - 0$ - 0$ - 0
RX02Cyanide, >50% Debris, >590 mg/Kg Total CN.

Physical State: Various.

Permissible Waste Codes: D002-43, Listed.RX02C1EA11$ - 0$ - 0$ - 0$ - 0
RX02C2EA11$ - 0$ - 0$ - 0$ - 0
RX02C3EA11818$ - 0$ - 0$ - 0$ - 0
RX02C4EA111$ - 0$ - 0$ - 0$ - 0
RX03Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN.

Physical State: Various.

Permissible Waste Codes: D002-43, Listed.RX06C1EA1044$ - 0$ - 0$ - 0$ - 0
RX06C4EA211$ - 0$ - 0$ - 0$ - 0
RX04Cyanide Liquids, Solids, <50% Debris, 1%-10% Total CN.

Physical State: Various.

Permissible Waste Codes: D002-43, Listed.RX07C1EA3011$ - 0$ - 0$ - 0$ - 0
RX07C4EA411$ - 0$ - 0$ - 0$ - 0
RX05Cyanide Liquids, Solids, <50% Debris, >10% Total CN. Physical State: Various. Permissible Waste Codes: D002-43, Listed.RX05C1EA11$ - 0$ - 0$ - 0$ - 0
RX08C4EA62525$ - 0$ - 0$ - 0$ - 0
RX08Reactive Metals, e.g., powders, dusts, fines. Air/Water Reactive. Shipped under oil and/or other Generator special packaging may be required. (See 1.2.3).

Physical State: Solid.

Permissible Waste Codes: D001, D003-11, Listed.RX08C1EA611$ - 0$ - 0$ - 0$ - 0
RX97Reactive, Ignitable, and Toxic Liquid for RCRA incineration. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Liquid.

Permissible Waste Codes: D001, D003-43, Listed.RX97C1EA122$ - 0$ - 0$ - 0$ - 0
RX97C4EA111$ - 0$ - 0$ - 0$ - 0
RX97B5EA11,7941,794$ - 0$ - 0$ - 0$ - 0
TX01Chromium, Hexavalent, <1% Cr+6, Characteristic Liquids, Solids, Sludges.

Physical State: Various.

Permissible Waste Codes: D001 (OX), D004-11.TX01C1EA11$ - 0$ - 0$ - 0$ - 0
TX01C4EA14242$ - 0$ - 0$ - 0$ - 0
TX06Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. Total VOC <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include RCRA hazardous asbestos. (See 1.2.8.1.e.).

Physical State: Debris.

Permissible Waste Codes: D004-11, Listed Inorganics.TX06B6CD806,9856,985$ - 0$ - 0$ - 0$ - 0
TX06C1EA1922$ - 0$ - 0$ - 0$ - 0
TX06C2EA17070$ - 0$ - 0$ - 0$ - 0
TX06C3EA12218218$ - 0$ - 0$ - 0$ - 0
TX06C4EA1064905905$ - 0$ - 0$ - 0$ - 0
TX06C6EA438766766$ - 0$ - 0$ - 0$ - 0
TX07Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). Must carry organic waste code(s) unless pipes, hoses, tubes, or equipment are present. May include inorganic Waste Code(s) and/or RCRA hazardous asbestos. (See 1.2.8.1.e.).

Physical State: Debris.

Permissible Waste Codes: D004-43, Listed, No F020-32.TX07C1EA8714646$ - 0$ - 0$ - 0$ - 0
TX07C2EA937070$ - 0$ - 0$ - 0$ - 0
TX07C3EA69237237$ - 0$ - 0$ - 0$ - 0
TX07C4EA1541,3401,340$ - 0$ - 0$ - 0$ - 0
TX07C6EA32341,3351,335$ - 0$ - 0$ - 0$ - 0
TX12Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Characteristic only.

Physical State: Liquid.

Permissible Waste Codes: D004-11.TX12C1EA24001313$ - 0$ - 0$ - 0$ - 0
TX12C2EA2422$ - 0$ - 0$ - 0$ - 0
TX12C3EA766$ - 0$ - 0$ - 0$ - 0
TX12C4EA987171$ - 0$ - 0$ - 0$ - 0
TX16Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic only.

Physical State: Various.

Permissible Waste Codes: D004-11.TX16C2EA401010$ - 0$ - 0$ - 0$ - 0
TX16C3EA131515$ - 0$ - 0$ - 0$ - 0
TX16C4EA268403403$ - 0$ - 0$ - 0$ - 0
TX16C6EA2733$ - 0$ - 0$ - 0$ - 0
TX20Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic and/or Listed.

Physical State: Various.

Permissible Waste Codes: D004-11, Listed.TX20C1EA188$ - 0$ - 0$ - 0$ - 0
TX20C2EA122$ - 0$ - 0$ - 0$ - 0
TX20C3EA122$ - 0$ - 0$ - 0$ - 0
TX20C4EA8182182$ - 0$ - 0$ - 0$ - 0
TX20C5EA811$ - 0$ - 0$ - 0$ - 0
TX21Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents.

Physical State: Liquid.

Permissible Waste Codes: D004-11, Listed.TX21C3EA122$ - 0$ - 0$ - 0$ - 0
TX21C4EA18585$ - 0$ - 0$ - 0$ - 0
TX22Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents.

Physical State: Various.

Permissible Waste Codes: D004-43, Listed.TX22C1EA311$ - 0$ - 0$ - 0$ - 0
TX22C2EA22$ - 0$ - 0$ - 0$ - 0
TX22C3EA444$ - 0$ - 0$ - 0$ - 0
TX22C4EA152152$ - 0$ - 0$ - 0$ - 0
TX22B1LB5,0235,023$ - 0$ - 0$ - 0$ - 0
TX22B2LB27355,281355,281$ - 0$ - 0$ - 0$ - 0
TX24Organic Solvents, Technical Grade, pure or mixed solutions, with or without water and/or metals, pumpable if bulk, Flashpoint 140°F or greater.

Physical State: Liquid.

Permissible Waste Codes: D004-43, Listed.TX24C1EA11$ - 0$ - 0$ - 0$ - 0
TX24C4EA102727$ - 0$ - 0$ - 0$ - 0
TX99Military Submarine Tiles, Demil-required via RCRA Incineration. For use even when no toxic Waste Codes apply. Requires direct shipment to TSDF. CD required. See 2.7.1. Not for bulk removals. Physical State: Solid. Permissible Waste Codes: D004-D043.TX99C7LB264430,36730,367$ - 0$ - 0$ - 0$ - 0

CLIN Suffix Table

CLIN Suffix Table
Containerized Wastes
CLIN Suffix→C1C2C3C4
Container Size:
Type:Up to 5 Gal
(DM/DF)Up to 15 Gal
(DM/DF)Up to 30 Gal
(DM/DF)Up to 55 Gal

(DM/DF)

Unit of Issue:EAEAEAEA
CLIN Suffix→C5C6C7C8
Container Size:
Type:Up to 110 Gal
(DM/DF)CYB, TRIWALL or PALLETContainerized PoundsContainerized Kilograms
Unit of Issue:EAEALBKG
Pumpable Liquid Wastes Removed in Totes / IBCs
CLIN Suffix→T1T2T3
Container Size:

Type: Up to 220 GL 850 Liters (TP) Up to 275 GL 1,050 Liters (TP) Up to 330 GL 1,250 Liters

(TP)

Unit of Issue: EA EA EA

Bulk Solid & Liquid Wastes
CLIN Suffix→B1B2B3B4
Bulk Load Description:Bulk Heavy Solids (>600 Lbs/Yd3)

Priced per Lb, Based on Bulk Loads that are…

<10,000 Lbs10K-20K Lbs20K-30K Lbs>30,000 Lbs
Unit of Issue:LBLBLBLB
Notes:Weights shown above are net weights of actual waste per bulk load.

Not to be used for lightweight solids weighing less than 600 Lbs/yd3.

CLIN Suffix→B5B6B7B8B9
Bulk Load Description:Bulk Pumpable Liquids
Removed via Vac Truck or TankerBulk Solids

Lightweight (<600 Lbs/Yd3)

Removed via Rolloff BoxBulk Pumpable Liquids
Removed via Vac Truck or TankerBulk Heavy Solids

(>600 Lbs/Yd3) (>350 Kg/M3) Bulk Pumpable Liquids Removed via Vac Truck or Tanker

Unit of Issue:Gallons
(GL)Cubic Yards
(CD)Liters
(L)Kilograms
(KG)Pounds

(LB)

Minimum Load Ordered:1,500-Gallons75% of
ROB Capacity5,000 Liters

(1,320 U.S. Gal)

5,000 KG

(11K U.S. Lbs) Case-by-Case Restricted Use

Compressed Gas Cylinders (Sizes do not include valve or handle.)
CLIN Suffix→MEM1M2M3
Size Category:LectureSmallMediumLarge
Size Up To:3" x 12"4" x 24"12" x 36"16" x 56"
Unit of Issue:EAEAEAEA
CLIN Suffix ME (Misc. Each) also has other applications, e.g., on-site vacuumed/pumped 55-gal drums.