DRAFT CLIN LIST.xlsx
XLSX spreadsheet 31 KB Posted
- Attached to
- Sources Sought Robins Hazardous Waste Removal and Disposition Services Federal contract opportunity
- Solicitation number
- 21BE148
- Issued by
- Defense Logistics Agency
About this file
This sources sought notice requests capabilities statements from small businesses interested in performing hazardous waste removal and disposition services at Robins Air Force Base in Georgia. Firms must demonstrate experience with RCRA hazardous wastes, non-RCRA wastes, universal wastes, compressed gases, and PCBs. The indefinite delivery indefinite quantity contract would have a one-year base period and one-year option, awarded on a firm-fixed-price basis through beta.sam.gov. Responses are due by April 12, 2022. Interested small businesses must address their ability to meet the 50% limitation on subcontracting to non-similarly situated entities given disposal costs represent a large portion of work. Capabilities statements should identify relevant experience in the last five years, as well as any similarly situated treatment, storage, and disposal facilities proposed for use. The Defense Logistics Agency will determine if a set-aside is appropriate.
View the file
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAFT CLIN LIST
| Base | ||
| CLIN | Description | Base |
CLIN
| Base | ||
| CLIN | Service CLINs | Base |
CLIN
| 6310 | Overpack waste into contractor-provided overpack or salvage 85- to 110-GL drum. (See 1.2.12). | 6310 | ||
| 6311 | Overpack waste into contractor-provided overpack or salvage 5- to 55-GL drum. (See 1.2.12). | 6311 | ||
| 6311DD | Provide loose packing service to place waste into one government-provided 55-gallon container. (See 1.2.13 and 3.27). | 6311DD | ||
| 6311EE | Provide loose packing service to place waste into one government-provided military tri-wall or cubic yard box. (See 1.2.13 and 3.27). | 6311EE | ||
| 6321 | Provide lab packing service to pack small quantity packages into into one (1) contractor-provided container up to 55-gallons in size. (See 3.27). | 6321 | ||
| 6324 | Provide lab packing service to pack small quantity packages into into one (1) contractor-provided container up to 5-gallons in size. (See 3.27). | 6324 | ||
| 6388AA | Robins AFB Bulk Liquid Transport (See 3.34) | 6388AA | ||
| 6400AA | Prepare Waste Profile Sheet/Form (See 3.25). | 6400AA | ||
| 6502WA | Perform Management Services as described in PWS at RAFB. May include but is not limited to preparation of waste documentation, labeling and marking containers, transportation of waste, pumping of waste, spill response, internal and external reporting, operate 90-day or CSF, etc. | |||
| (See 3.28). | 6502WA | |||
| 6503 | Provide certificate of disposal (See 2.1). | 6503 | ||
| 6609AA | Perform management services, may include repackaging the contents of one compressed gas cylinder that is not DoT transportable (non-inert gas) (See 2.5.3) | 6609AA | ||
| 6609BB | Peform management services, may include replacing a valve that is not operable (See 2.5.3) | 6609BB | ||
| 1002SV | Industrial Cleaning Services, Daily, Crew of Two (2) (See 3.11). | 1002SV | ||
| 1003SV | Industrial Cleaning Services, Weekly, Crew of Two (2) (See 3.12). | 1003SV | ||
| 1007SV | Industrial Cleaning Services, Daily, Crew of Three (3) (See 3.14). | 1007SV | ||
| 1008SV | Industrial Cleaning Services, Weekly, Crew of Three (3) (See 3.15). | 1008SV | ||
| 1022RE | Monthly Rental of a 20-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1022RE | ||
| 1025RE | Daily Rental of a 25-yd3 Lined Rolloff Box (ROB) With Cover (See 3.2). | 1025RE | ||
| 1026RE | Weekly Rental of a 25-yd3 Lined Rolloff Box (ROB) With Cover (See 3.3). | 1026RE | ||
| 1027RE | Monthly Rental of a 25-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1027RE | ||
| 1028RE | Annual Rental of a 25-yd3 Lined Rolloff Box (ROB) With Cover (See 3.5). | 1028RE | ||
| 1042RE | Monthly Rental of a 40-yd3 Lined Rolloff Box (ROB) With Cover (See 3.4). | 1042RE | ||
| 1060RE | Daily Rental of a 20- or 25-yd3 Vacuum Box (See 3.6). | 1060RE | ||
| 1061RE | Weekly Rental of a 20- or 25-yd3 Vacuum Box (See 3.7). | 1061RE | ||
| 1071RE | Weekly Rental of a FRAC TANK With Containment (See 3.8). | 1071RE | ||
| 1072RE | Monthly Rental of a FRAC TANK With Containment (See 3.9). | 1072RE | ||
| 1080SV | Surcharge for Weekend Work, Daily, Crew of Two (2) (See 3.17). | 1080SV | ||
| 1081SV | Surcharge for Weekend Work, Daily, Crew of Three (3) (See 3.18). | 1081SV | ||
| 1082SV | Additional Charge for Hydro/Water Blasting Work, Daily, Crew of Three (3) (See 3.19). | 1082SV | ||
| 1083SV | Additional Charge for Permit - Required Confined Space Work, Daily, Crew of Three (3) (See 3.20). | 1083SV | ||
| 1084SV | Additional Charge for Super Vacuum Truck Work, Daily, Crew of Three (3) (See 3.21). | 1084SV | ||
| 1095SV | 1-Business Day Expedite/Performance (See 1.2.11). | 1095SV | ||
| 1096SV | 3-Business Day Expedite/Performance (See 1.2.11). | 1096SV | ||
| 1097SV | 5-Business Day Expedite/Performance (See 1.2.11). | 1097SV | ||
| 1098SV | 10-Business Day Expedite/Performance (See 1.2.11). | 1098SV | ||
| 1099SV | Surcharge for Expedited Commencement of ICS Work, Crew of Two-Three (2-3) (See 3.22). | 1099SV | ||
| 1100SV | Move Empty ROB, VAC BOX, OR FRAC TANK (see 3.10.1). | 1100SV | ||
| 1200RE | Initial Placement or Removal of Empty Rented Rolloff Box or Vacuum Box (See 3.10). | 1200RE | ||
| Base | ||||
| CLIN | Containers/Supplies | Base |
CLIN
| 1016SP | Provide Storm drain filters, 48"x36", 18" depth, minimum requirements; 1.38 gallon oil capacity, can hold 40 pounds of sediment, 1EA=10 filters | 1016SP | |
| 1156SP | Provide 5 GL, poly DR, new, OPN, pail w/screw top, locking lid UN 1H2/Y1.2/60 | 1156SP | |
| 1419SP | Provide 55 GL, metal DR, new, OPN, BLTRNG, UN 1A2/Y1.6/150 | 1419SP | |
| 1404SP | Provide 55 GL, poly DR, new, OPN, LLR, UN 1H2/X200/S AND 1H2/Y250/S | 1404SP | |
| 1407SP | Provide 55 GL, poly DR, new, CLO, UN 1H1/Y1.9/150 | 1407SP | |
| 1330SP | Provide 30 GL, poly DR, new, OPN, lever lock ring, UN 1H2/Y180/S | 1330SP | |
| 1328SP | Provide 30 GL, poly DR, new, CLO, UN 1H1/Y1.8/100 | 1328SP | |
| 1354SP | Provide 30 GL, metal DR, new, CLO, EP lined, UN 1A1/Y1.6/200 | 1354SP | |
| 1341SP | Provide 30 GL, metal DR, new, OPN, EP lined, 1A2/Y1.8/100 | 1341SP | |
| 1411SP | Provide 55 GL, metal DR, new, CLO, UN 1A1/Y1.8/300 | 1411SP | |
| 1369SP | Provide 30 GL, metal DR, recon, OPN, UN 1A2/Y1.2/100 | 1369SP | |
| 1468SP | Provide 55 GL, metal DR, recon, OPN, UN 1A2/Y1.2/100 | 1468SP | |
| 1661SP | Provide 4 Ft bulb box, non UN rated, 16"x16"x48" | 1661SP | |
| 1668SP | Provide 8 Ft bulb box, non UN rated, 12"x12"x96" | 1668SP | |
| Base | |||
| CLIN | Analytical Services | Base |
CLIN
| 1001SA | Perform sampling and analysis to determine Waste Characteristics (D001-D0043) and UHCs using current SW-846 Methods. Provide Hazardous Waste Profile Sheet (HWPS). (See 3.26) | 1001SA | |
| 1002SA | Perform sampling and analysis to determine waste characteristics for Ignitability (D001), Corrosivity (D002), and Reactivity (D003) using current EPA approved methods. | ||
| Five (5) business day deliverables required (See 3.24). | 1002SA | ||
| 1003SA | Perform sampling and analysis to determine TCLP concentrations of toxic Metals and Organic Compounds corresponding to EPA Waste Codes D004-D043 and UHCs, using current SW-846 Methods (See 3.24). | 1003SA | |
| 1030SA | Perform sampling and analysis to determine Toxicity Characteristics of eight (8) RCRA Metals (D004-D011) and four (4) UHC Metals via TCLP, SW-846 Method 1311 and current SW-846 quantitative detection method(s) (See 3.24). | 1030SA | |
| 1200SA | Perform sampling and analysis to determine Total concentrations of Volatile Organic Compounds (VOC) corresponding to EPA Waste Codes and UHCs, using EPA Method 8260D, and updates thereto (See 3.24). | 1200SA | |
| 1208SA | Perform sampling and anlysis to determine concentration of total Polychlorinated Biphenyls (PCBs) using current EPA approved method(s) (See 3.24).. | 1208SA | |
| 1210SA | Perform sampling and analysis to determine total concentration of F001-F005 solvents using current SW-846 Methods (See 3.24). | 1210SA | |
| 1211SA | Perform sampling and analysis to determine total Halogenated Organic Compounds (HOC) regulated under 40 CFR, App III, Part 268.32 (full list of 106 parameters) using current SW-846 Methods (See 3.24). | 1211SA | |
| 1302SA | Perform sampling and analysis to determine Oxidizing potential of liquids, Potassium Iodide (KI) Starch paper or other available qualitative (Positive or Negative) tests (See 3.24). | 1302SA | |
| 1303SA | Perform sampling and analysis to determine Oxidizing potential of solids, current SW-846 or other available qualitative (Positive or Negative) tests (See 3.24). | 1303SA | |
| 1307SA | Perform sampling and analysis to determine concentration of Total and Amenable Cyanides in liquids, solids, or sludges, using current SW-846 method(s) as applicable(See 3.24). | 1307SA | |
| 1310SA | Perform qualitative analysis to determine presence of Friable or Non-Friable Asbestos (See 3.24). | 1310SA | |
| 1370SA | Perform analysis to identify contents of a compressed gas cylinder and complete a Waste Profile Sheet (See 2.5.2 and 3.24). | 1370SA | |
| 1900SA | Test for PFAS in Drinking Water, EPA Method 537.1, or update thereto (See 3.24). | 1900SA | |
| 1904SA | Provide sampling and analysis for Per- and Polyfluoroalkyl Substances (PFAS) using Liquid Chromatography Tandem Mass Spectrometry (LC/MS/MS) with Isotope Dilution or Internal Standard Quantification in Matrices Other Than Drinking Water. Sample bottles must be provided by the laboratory. Only accredited laboratories per current DoD QSM may be used (See 3.24). | 1904SA | |
| Base | |||
| CLIN | Batteries for Recycle/Disposal | Base |
CLIN
BA01 Alkaline Batteries, may be managed as Universal Waste (UW) or Hazardous Waste (HW) for Recycling or Disposal (See 2.6.1).
Physical State: Various Permissible Waste Codes: UW, D002,D004-11.
| BA01C7 | |
| BA03 | Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002, D004-11 | BA03C7 | |
| BA04 | Lead Acid Batteries, Wet, Dry, or Gel Pack, for mandatory recycling (See 2.6.1). |
Physical State: Various
| Permissible Waste Codes: UW, D002, D004-11. | BA04C7 | |
| BA05 | Lithium Ion (Li-Ion) Batteries, for mandatory recycling. Physical State: Solid | |
| Permissible Waste Codes: UW, D002-11. | BA05C7 | |
| BA08 | Lithium Sulfur Dioxide (LiSO2) Batteries, for Contractor's choice of recycling or disposal. |
Physical State: Solid
| Permissible Waste Codes: UW, D002-11. | BA08C7 | |
| BA09 | Lithium Thionyl Chloride (LiSCl) Batteries, for Contractor's choice of recycling or disposal. Physical State: Solid | |
| Permissible Waste Codes: UW, D002-11. | BA09C7 | |
| BA10 | Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal. Physical State: Solid | |
| Permissible Waste Codes: UW, D002-11. | BA10C7 | |
| BA11 | Magnesium (Mg) Batteries, for Contractor's choice of recycling or disposal. Physical State: Solid | |
| Permissible Waste Codes: UW, D002, D004-11. | BA11C7 | |
| BA12 | Mercury (Hg) Batteries, for mandatory recycling. Physical State: Solid | |
| Permissible Waste Codes: UW, D002, D004-11. | BA12C7 | |
| BA13 | Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling. Physical State: Various | |
| Permissible Waste Codes: UW, D002, D004-11. | BA13C7 | |
| BA14 | Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling. Physical State: Various | |
| Permissible Waste Codes: UW, D002, D004-11. | BA14C7 | |
| Base | ||
| CLIN | Corrosives | Base |
CLIN
CS01 Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS01C1 | ||
| CS01C2 | |||
| CS01C3 | |||
| CS01C4 | |||
| CS01B5 | |||
| CS03 | Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics | CS03C1 | ||
| CS03C3 | |||
| CS03C4 | |||
| CS04 | Corrosive Acids, Chromic (H2Cr04 ), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris. |
Physical State: Various
| Permissible Waste Codes: D001 (Oxidizer), D002, D004-11. | CS04C1 | ||
| CS04C2 | |||
| CS04C4 | |||
| CS07 | Corrosive Acids, Chromic (H2CrO4), >100 ppm Cr+6, Listed Liquids, Solids, Sludges, Debris. |
Physical State: Various
| Permissible Waste Codes:D001 (OX), D002, D004-11, F-Listed, U032 | CS07C1 | ||
| CS07C4 | |||
| CS07B5 | |||
| CS08 | Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water. |
Physical State: Liquid
| Permissible Waste Codes: D001 (Oxidizer), D002, D004-11, Listed Inorganics. | CS08C1 | ||
| CS08C4 | |||
| CS08B5 | |||
| CS10 | Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines. |
Physical State: Liquid
| Permissible Waste Codes: D002, D004-11, Listed Inorganics. | CS10C1 | ||
| CS10C2 | |||
| CS10C3 | |||
| CS10C4 | |||
| CS10C5 | |||
| CS10B5 | |||
| CS12 | Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/ Sludges/Solids/Debris. FLP ≥ 140°F. |
Physical State: Various
| Permissible Waste Codes: D002, D004-43, Listed. | CS12C1 | ||
| CS12C4 | |||
| CS12C6 | |||
| CS13 | Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, FLP ≥ 140°F. |
Physical State: Various
| Permissible Waste Codes: D002, D004-43, Listed. | CS13C1 | ||
| CS13C2 | |||
| CS13C4 | |||
| CS13C6 | |||
| CS13B5 | |||
| CS14 | Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries. |
Physical State: Various
| Permissible Waste Codes: D002, D004-11, Listed. | CS14C1 | ||
| CS14C2 | |||
| CS14C3 | |||
| CS14C4 | |||
| Base | |||
| CLIN | Compressed Gas Cylinders/Cartridges | Base |
CLIN
CY01 Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases | CY01M1 | ||
| CY01M2 | |||
| CY01M3 | |||
| CY01ME | |||
| CY02 | Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases. | CY02ME | ||
| CY02M1 | |||
| CY03 | Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases | CY03ME | |
| CY08 | Category 8 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases. |
Physical State: Comp. Gas
| Permissible Waste Codes: As applicable to contained gas or mixed gases | CY08ME | ||
| CY08M1 | |||
| CY10 | Cylinders, Acetylene, No Asbestos, for Recycle/Reuse. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY10M2 | |
| CY11 | Cylinders, Propane, 20-Lb "Grill Size", for Disposal, Recycle, or Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY11ME | |
| CY12 | Cylinders, Flammable, AVGAS, Ether Gas/Diesel Starting, for Disposal or Recycle. Diameter up to 3", Length up to 12". "ME" = 1 EA Cylinder. |
Physical State: Comp. Gas
| Permissible Waste Codes: D001. | CY12ME | |
| Base | ||
| CLIN | Flammable/Combustible/Ignitable | Base |
CLIN
FL01 Aerosols, Flammable/Combustible/Ignitable, non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW. (See 1.1.3).
Physical State: Various
| Permissible Waste Codes: UW, D001 (IGN), D004-43, Listed. | FL01C7 | |
| FL02 | Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components. |
Physical State: Solid
| Permissible Waste Codes: D001, D004-43, Listed. | FL02C1 | ||
| FL02C2 | |||
| FL02C3 | |||
| FL02C4 | |||
| FL03 | Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris. Primarily consists of incinerable, non-fuels-blendable materials. No isocyanates (see FL16). Use LP03 for loose packs. |
Physical State: Various
| Permissible Waste Codes: D001-2, D004-43, Listed. | FL03C1 | ||
| FL03C2 | |||
| FL03C3 | |||
| FL03C4 | |||
| FL03C5 | |||
| FL03B1 | |||
| FL03B6 | |||
| FL04 | Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only. |
Physical State: Various
| Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-43, Listed. | FL04C1 | ||
| FL04C2 | |||
| FL04C3 | |||
| FL04C4 | |||
| FL04B5 | |||
| FL05 | Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates. (See 2.6.1). |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL05C1 | ||
| FL05C2 | |||
| FL05C3 | |||
| FL05C4 | |||
| FL05C5 | |||
| FL05C6 | |||
| FL05B5 | |||
| FL06 | Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates. (See 2.6.1). |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL06C1 | ||
| FL06C3 | |||
| FL06C4 | |||
| FL06C5 | |||
| FL08 | Flammable Resuspendable Solids/Sludges, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates. (See 2.6.1). |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL08B5 | |
| FL11 | Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors. |
Physical State: Liquid
| Permissible Waste Codes: UW (Pesticides Only), D001 (IGN), D004-43, Listed. | FL11C1 | ||
| FL11C4 | |||
| FL12 | Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors. |
Physical State: Various
| Permissible Waste Codes: UW (Pesticides Only), D001 (IGN), D004-43, Listed. | FL12C4 | ||
| FL12C5 | |||
| FL12C6 | |||
| FL13 | Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives). |
Physical State: Various
| Permissible Waste Codes: D001(OX), D002, D004-43, Listed. | FL13C1 | ||
| FL13C3 | |||
| FL13C4 | |||
| FL15 | Water Contaminated with Common Solvents, pumpable if bulk, <2,500 BTU/Lb. |
Physical State: Liquid
| Permissible Waste Codes: D001 (IGN), D004-43, Listed | FL15C4 | ||
| FL15B5 | |||
| FL16 | Non-Reactive paints and other coatings listing isocyanates in the ingredients. Use LP16 for loose packs. |
Physical State: Various.
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | FL16C1 | ||
| FL16C2 | |||
| FL16C3 | |||
| FL16C4 | |||
| FL16C5 | |||
| FL16C6 | |||
| FL99 | Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed | FL99C1 | ||
| FL99C3 | |||
| Base | |||
| CLIN | Lab Packs/Loose Packs | Base |
CLIN
LP01 Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.
Physical State: Various
| Permissible Waste Codes: D002, D004-8, D010-11, Listed | LP01C1 | ||
| LP01C2 | |||
| LP01C3 | |||
| LP01C4 | |||
| LP01C6 | |||
| LP03 | Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14, for mandatory RCRA incineration. |
Physical State: Various Permissible Waste Codes: D001-2, D004-8, D010-43, Listed.
| LP03C1 | ||
| LP03C2 | ||
| LP03C3 | ||
| LP03C4 | ||
| LP03C6 | ||
| LP04 | Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals. |
Physical State: Various
| Permissible Waste Codes: N/A. | LP04C1 | ||
| LP04C2 | |||
| LP04C3 | |||
| LP04C6 | |||
| LP08 | Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Special packaging may be required. |
Physical State: Various
| Permissible Waste Codes: D001-8, D010-43, Listed. | LP08C1 | |
| LP09 | Lab Packs/Loose Packs, Toxic Metals. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-11, Listed Inorganics. | LP09C1 | ||
| LP09C4 | |||
| LP11 | Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-43, P-Listed, U-Listed. | LP11C1 | ||
| LP11C2 | |||
| LP11C3 | |||
| LP11C4 | |||
| LP12 | Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration. |
Physical State: Various
| Permissible Waste Codes: D004-8, D010-43, U-Listed. | LP12C1 | ||
| LP12C2 | |||
| LP12C3 | |||
| LP12C4 | |||
| LP14 | Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb, No Isocyanates. May contain <50% water-based paints. Formerly CLIN FL14. |
Physical State: Various
| Permissible Waste Codes: D001 (IGN), D004-43, Listed | LP14C1 | ||
| LP14C2 | |||
| LP14C3 | |||
| LP14C4 | |||
| LP14C5 | |||
| LP14C6 | |||
| LP15 | Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06. (See 3.27). |
Physical State: Various
| Permissible Waste Codes: N/A. | LP15C1 | ||
| LP15C2 | |||
| LP15C3 | |||
| LP15C4 | |||
| LP15C5 | |||
| LP15C6 | |||
| LP16 | Loose-Packed Paints. Non-Reactive paints and other coatings listing isocyanates in the ingredients. |
Physical State: Various.
| Permissible Waste Codes: D001 (IGN), D004-43, Listed. | LP16C1 | ||
| LP16C2 | |||
| LP16C3 | |||
| LP16C4 | |||
| LP16C5 | |||
| LP16C6 | |||
| Base | |||
| CLIN | Non-RCRA, Non-State and State Regulated | Base |
CLIN
NR01 Non-RCRA Solids/Debris, for direct disposal at a RCRA Subtitle D landfill, or equivalent. Passes paint filter test. No asbestos. May include drained/dry non-PCB transformers, ballasts, capacitors, and related equipment.
Physical State: Solid
| Permissible Waste Codes: N/A. | NR01C1 | ||
| NR01C2 | |||
| NR01C3 | |||
| NR01C4 | |||
| NR01C5 | |||
| NR01C6 | |||
| NR01B1 | |||
| NR01B2 | |||
| NR01B3 | |||
| NR01B4 | |||
| NR02 | Non-RCRA Solids/Debris with Asbestos, for direct disposal at a TSCA/RCRA Subtitle D landfill, or equivalent. Passes paint filter test. Special packaging may be required. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR02C1 | ||
| NR02C2 | |||
| NR02C4 | |||
| NR03 | Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR03C1 | ||
| NR03C3 | |||
| NR03C4 | |||
| NR03C5 | |||
| NR03B5 | |||
| NR04 | Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons. |
Physical State: Liquid
| Permissible Waste Codes: N/A. | NR04C1 | ||
| NR04C2 | |||
| NR04C3 | |||
| NR04C4 | |||
| NR04B5 | |||
| NR05 | Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D landfill, or equivalent. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment. |
Physical State: Various
| Permissible Waste Codes: N/A. | NR05C1 | ||
| NR05C2 | |||
| NR05C3 | |||
| NR05C4 | |||
| NR05B5 | |||
| NR09 | Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal and/or Plastic/Poly, crushed or damaged, for Contractor's choice of Recycle or Disposal. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR09C3 | ||
| NR09C4 | |||
| NR09T2 | |||
| NR09T3 | |||
| NR10 | Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Plastic/Poly Only, Intact, for Contractor's choice of Recycle or Disposal. Totes (T1-T3) may have metal components. |
Physical State: Solid
| Permissible Waste Codes: N/A. | NR10C3 | ||
| NR10C4 | |||
| NR10T2 | |||
| NR10T3 | |||
| NR90 | Non-RCRA AFFF-Related Solids/Sludges/Debris for RCRA Incineration, e.g., soil, gravel, filter media, tank bladders, etc. May contain some free liquids. CD required (See 2.4). |
Physical State: Various
| Permissible Waste Codes: N/A | NR90C4 | ||
| NR90C6 | |||
| NR93 | Non-RCRA AFFF Concentrate Liquids for RCRA Incineration, pumpable, unused or >10% AFFF product by volume. CD required. (See 2.4). |
Physical State: Liquid.
| Permissible Waste Codes: N/A. | NR93C1 | ||
| NR93C4 | |||
| NR94 | Non-RCRA AFFF Rinsates and other impacted waters for RCRA Incineration, Pumpable, Used or >90% water by volume. Bulk removals may be from storage tanks, containment, storm sewer, ground and surface waters. CD required (See 2.4). |
Physical State: Liquid.
| Permissible Waste Codes: N/A. | NR94T2 | |
| NR98 | Non-RCRA Military Articles, Demil-Required, e.g., boots, gloves, CDE kits, filters, masks, MOPP suits, etc. for direct disposal at a RCRA Subtitle D landfill, or equivalent. CD required. No uniforms (NR99) or submarine tiles (TX99). |
Physical State: Various
| Permissible Waste Codes: N/A. | NR98C1 | ||
| NR98C2 | |||
| NR98C3 | |||
| NR98C4 | |||
| NR98C6 | |||
| Base | |||
| CLIN | PCB Related | Base |
CLIN
PC01 PCB wastes containing or contaminated with a ≥50 ppm PCB Source (≥5 ppm in CA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required. (See 2.3) Physical State: Various
| Permissible Waste Codes: D001-43, Listed. | PC01C8 | |
| PC02 | PCB Mineral Oil from Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA (See 2.3). |
Physical State: Various
| Permissible Waste Codes: D001-43, Listed. | PC02C8 | |
| PC06 | PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, ≥50 ppm PCBs (≥5 ppm in CA), Non-RCRA, CD or Cert of Recycling required. (See 2.3) |
Physical State: Various
| Permissible Waste Codes: N/A. | PC06C8 | |
| PC09 | PCB Solids/Debris Contaminated with <50 ppm Source (<5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. (See 2.3) |
Physical State: Solid
| Permissible Waste Codes: N/A. | PC09C8 | |
| PC10 | PCB Solids/Debris Contaminated with ≥50 ppm Source (≥5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD or Cert of Recycling required. (See 2.3) |
Physical State: Solid
| Permissible Waste Codes: N/A. | PC10C8 | |
| Base | ||
| CLIN | Profile-Based CLIN Waste Descriptions for Per- and Polyfluorinated Alkyl Substances (PFAS) | Base |
CLIN
PF03 AFFF and other PFAS-related Liquids/Waters, Non-RCRA, >100 ppm PFAS, for treatment and disposal at RCRA Subtitle C Landfill or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates & Concentrates. CD Required.
Physical State: Liquid
| Permissible Waste Codes: N/A | PF03C1 | ||
| PF03C4 | |||
| PF03T2 | |||
| PF04 | AFFF and other PFAS-related Solids/Debris, Non-RCRA, <1.0 ppm PFAS, for direct disposal at RCRA Subtitle C Landfill or equivalent. Passes Paint Filter Test. No Cylinders. CD Required. |
Physical State: Solid
| Permissible Waste Codes: N/A | PF04C6 | |
| Base | ||
| CLIN | Recycle/Recovery | Base |
CLIN
RE01 Lamps, Fluorescent, Intact. Includes CFLs, U-Bent, Circulars.
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE01C7 | |
| RE02 | Lamps, Fluorescent, Crushed/Broken, may contain filters. |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE02C1 | ||
| RE02C4 | |||
| RE03 | Lamps, Halogen. |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE03C7 | |
| RE04 | Lamps, High Intensity Discharge (HID) and/or Light Emitting Diode (LED). |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE04C7 | |
| RE05 | Lamps, Mercury/Mercury Vapor. |
Physical State: Solid
| Permissible Waste Codes: UW, D004-11. | RE05C7 | |
| RE06 | Lamps, Metal Halide and Metal Hydride, including Sodium. |
Physical State: Solid
| Permissible Waste Codes: UW, D003-11. | RE06C7 | |
| RE08 | Mercury, High, Dental Amalgams, Debris & Residues, Hg >260 mg/Kg. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11 (See 3.30) | RE08C1 | ||
| RE08C4 | |||
| RE09 | Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11. | RE09C1 | |
| RE10 | Antifreeze, used and unused, for energy recovery (recycling, fuels blending). Note: RE10ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator. |
Physical State: Liquid
| Permissible Waste Codes: UW, D004-11 | RE10C1 | ||
| RE10C2 | |||
| RE10C3 | |||
| RE10C4 | |||
| RE11 | Used Oil, <10% Water, <1,000 ppm total organic halides (TOX), for energy recovery (recycling, fuels blending). Note: RE11ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator. Physical State: Liquid Permissible Waste Codes: UW, D004-11 | RE11C1 | |
| RE11C3 | |||
| RE11C4 | |||
| RE13 | Used Oil Filters, Drained and Undrained, and/or Fully Drained Fuel Filters. |
Physical State: Various
| Permissible Waste Codes: UW, D004-11 | RE13C1 | ||
| RE13C3 | |||
| RE13C4 | |||
| Base | |||
| CLIN | Reactive | Base |
CLIN
RX01 Aerosols, Foaming, Isocyanates or other reactives.
Physical State: Various
| Permissible Waste Codes: UW, D001-43, Listed. | RX01C7 | |
| RX03 | Cyanide Liquids, Solids, <50% Debris, 590-10,000 mg/Kg (1%) Total CN. |
Physical State: Various
| Permissible Waste Codes: D002-11, Listed | RX03C4 | ||
| RX03B5 | |||
| RX07 | Polymerizing Materials, e.g, Styrene, Isocyanates, Acrylates, etc. |
Physical State: Various
| Permissible Waste Codes: D001-11, Listed. | RX07C1 | ||
| RX07C2 | |||
| RX07C3 | |||
| RX07C4 | |||
| RX07C6 | |||
| RX13 | Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special packaging may be required. Packed in < gallon containers. No Lab Packs or Loose Packs. |
Physical State: Various
| Permissible Waste Codes: D001-11, Listed | RX13C1 | |
| RX99 | Military Items, Demil-Required, Reactive, Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. (No Batteries) for Conventional RCRA Treatment and Disposal. Must Carry D003. CD required. |
Physical State: Various
| Permissible Waste Codes: D001-D043, Listed. | RX99C1 | |
| Base | ||
| CLIN | Toxic | Base |
CLIN
TX06 Debris, Inorganic Constituents Only. >50% debris by volume, >60 mm (~2.5") particle size. No free liquids unless incidental rainwater or condensation (see TX20). Refer to Section 1.2.8.1.e.
Physical State: Debris
| Permissible Waste Codes: D004-11, Listed Inorganics. | TX06C1 | ||
| TX06C2 | |||
| TX06C3 | |||
| TX06C4 | |||
| TX06B1 | |||
| TX06B6 | |||
| TX07 | Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos. Section 1.2.8.1.e. |
Physical State: Debris
| Permissible Waste Codes: D004-43, Listed, but no F020-32. | TX07C1 | ||
| TX07C2 | |||
| TX07C3 | |||
| TX07C4 | |||
| TX07B1 | |||
| TX07B6 | |||
| TX09 | High Halogen Liquids/Sludges/Solids/Debris, Non-Flammable, Includes Solvents, Herbicides and Pesticides. |
Physical State: Various
| Permissible Waste Codes: UW, D004-43, Listed. | TX09C1 | ||
| TX09C4 | |||
| TX10 | Metals in Wastewater, <5% Suspended Solids, <1% Total Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. |
Physical State: Liquid
| Permissible Waste Codes: D004-11, Listed Inorganics. | TX10C4 | ||
| TX10B5 | |||
| TX12 | Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Characteristic only. |
Physical State: Liquid
| Permissible Waste Codes: D004-11. | TX12C1 | ||
| TX12C2 | |||
| TX12C3 | |||
| TX12C4 | |||
| TX12B5 | |||
| TX13 | Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Listed, or Listed + Characteristic. |
Physical state: Liquid
| Permissible Waste Codes: D004-11, Listed | TX13C1 | ||
| TX13C2 | |||
| TX13C3 | |||
| TX13C4 | |||
| TX16 | Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic only. |
Physical State: Various
| Permissible Waste Codes: D004-11. | TX16C3 | ||
| TX16C4 | |||
| TX16B1 | |||
| TX16B2 | |||
| TX16B3 | |||
| TX16B4 | |||
| TX17 | Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Listed, or Listed + Characteristic. |
Physical State: Various
| Permissible Waste Codes: D004-11, Listed Inorganics | TX17C1 | ||
| TX17C4 | |||
| TX20 | Metals-Bearing Debris/Solids/Sludges with Free Liquids, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic and/or Listed. |
Physical State: Various
| Permissible Waste Codes: D004-11, Listed | TX20C3 | ||
| TX20C4 | |||
| TX21 | Organics Contaminated Water, Pumpable, <10% Suspended Solids, <10% Organics, e.g., Toluene, Phenol in water. Not more toxic than common solvents. |
Physical State: Liquid
| Permissible Waste Codes: D004-43, Listed | TX21C1 | ||
| TX21C4 | |||
| TX22 | Organics in Solids/Sludges/Debris, i.e. soil, tank & still bottoms, adhesives, filtercake. Not more toxic than common solvents. |
Physical State: Various
| Permissible Waste Codes: D004-43, Listed. | TX22C1 | ||
| TX22C4 | |||
| TX22C6 | |||
| TX22B1 | |||
| TX22B2 | |||
| TX22B3 | |||
| TX22B4 | |||
| TX22B6 | |||
| TX24 | Organic Solvents, Technical Grade, pure or mixed solutions, with or without water and/or metals, pumpable if bulk, Flashpoint ≥140°F. |
Physical State: Liquid
| Permissible Waste Codes: D004-43, Listed. | TX24C1 | ||
| TX24C2 | |||
| TX24C3 | |||
| TX24C4 | |||
| TX24C5 | |||
| TX25 | Toxic Blast Media/Debris containing DOE-Exempt Naturally Occurring Radioactive Materials (NORM) measuring less than 2,000 pCi/g. Contains RCRA regulated metals. All Generators must first obtain authorization for disposal from US Army Joint Munitions Command, Rock Island Arsenal. (See Section 3.35). |
Physical State: Solid.
| Permissible Waste Codes: D004-11. | TX25B1 | ||
| TX25B2 | |||
| TX26 | Toxic Blast Media/Debris containing DOE-Exempt Naturally Occurring Radioactive Materials (NORM) measuring less than 2,000 pCi/g. Contains RCRA regulated metals and organics. All Generators must first obtain authorization for disposal from US Army Joint Munitions Command, Rock Island Arsenal. (See Section 3.35). |
Physical State: Solid.
| Permissible Waste Codes: D004-43, Listed. | TX26B1 | ||
| TX26B2 | |||
| TX26B3 | |||
| TX97 | Toxic Electron Tubes, intact, Demil-required. CD required. |
Physical State: Solid
| Permissible Waste Codes: D001-11 | TX97C1 | ||
| TX97C4 | |||
| TX97C6 | |||
| TX98 | Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Tents, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD required. |
Physical State: Solid Permissible Waste Codes: D001, D003, D004-11 TX98C7
File details come from the government source that posted it. Updated .