This document is a Draft Statement of Work (SOW) for the Bureau of Reclamation's Brackish Groundwater National Desalination Research Facility (BGNDRF) in Alamogordo, New Mexico. The project involves urgent well repair services for Well No. 2, which requires comprehensive maintenance including video inspection, equipment replacement, and cleaning. Specific tasks include pulling the existing 7.5 hp submersible pump located 159 ft below ground surface, addressing air production issues, installing new pump/motor/check valve components, and performing pre- and post-cleaning video documentation. The well, which has a 6-inch diameter and produces brackish water with approximately 6,000 mg/L total dissolved solids, currently flows at 70-72 gallons per minute and requires restoration to support future research operations.

The SOW outlines detailed technical requirements, safety protocols, and site access procedures, with a tentative site visit scheduled for October 17, 2025, at 500 Lavelle Road. Contractors must adhere to specific standards including ASTM and AWWA guidelines, OSHA safety standards, and Bureau of Reclamation safety protocols. The project is classified under NAICS code 237110 for water and sewer line construction, with work to be performed during facility operational hours (7:30 AM to 4:30 PM MDT, Monday through Friday). Coordination with the facility manager, Malynda Cappelle, is required for site access and project execution.

View the file

Other files

File Type Posted
SYNOPSIS_-_BGNDRF_Well_No_2_Service_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATEMENT OF WORK (Draft)

Bureau of Reclamation – Upper Colorado Region – Albuquerque Area Office

BRACKISH GROUNDWATER NATIONAL DESALINATION RESEARCH FACILITY

(Well No 2 Equipment Replacement, Cleaning, Video Inspection)

A. FOREWORD, DESCRIPTION, AND PURPOSE

The Bureau of Reclamation, Upper Colorado Region, Albuquerque Area Office, and Brackish Groundwater National Desalination Research Facility has a need for urgent services to inspect and clean existing Well No. 2.

The NAICS codes for this requirement are as follows:

237110 – Water and Sewer Line and Related Structures Construction

Project Description and Purpose. Description of work tasks is to perform a video inspection, replace equipment as necessary, and clean the existing BGNDRF Well No. 2. The well is producing air that is not bleeding off. Previous visits by a local well company have indicated there could be issues with the pump, motor, check valve, or other equipment. Well screen issues could also be present. Expected work needed includes pulling the well pump, injecting cleaning chemical, flushing the well, and performing video inspections before and after the cleaning operations. The pump, motor, check valve, and other appurtenances should be replaced. Well 2 has an estimated diameter of 6-inches and the submersible pump depth should be 159 ft below ground surface (bgs). The well is screened from 90 to 190 ft bgs and static water is around 70 ft bgs. The existing 7.5 hp pump originally flowed at 80 gallons per minute (gpm) but has recently declined to 70-72 gpm with a substantial amount of air. The electrical supply is 480VAC/3phase. The water is brackish with approximately 6,000 mg/L total dissolved solids.

The well has not been in regular use lately but is expected to be in service more once a treatment building is built. This well is necessary for research operations and needs to be put back into service as soon as possible.

B. ABBREVIATIONS, DEFINITIONS, AND ACRONYMS

The following acronyms apply to specifications Divisions 1 through 52:

AAOAlbuquerque Area Office
BGNDRFBrackish Groundwater National Desalination Research Facility
BORBureau of Reclamation
CLINContract Line Item Number
COContracting Officer
CORContracting Officer’s Representative.
CSContract Specialist
DOIDepartment of the Interior
FARFederal Acquisition Regulation
GPMGallon per Minute (gpm)
MDTMountain Daylight Time
OSHAOccupational Safety and Health Administration
RSHSReclamation Safety and Health Standards, 2014
VFDVariable Frequency Drive

C. STANDARDS AND SUBMITTALS

The following standards and generally accepted engineering principles or practices at this time and location shall govern well repairs under this action:

ASTM International (ASTM):

1. ASTM D 5978-96(11) Standard Guide for Maintenance and Rehabilitation of Groundwater Monitoring Wells

American Water Works Association (AWWA):

1. AWWA Manual M21 Groundwater

Submit the following using English and US Customary Units for review by the Government:

1.Submit Offeror’s safety plan, project scope, and schedule.
2.Submit for each manufacturer the following: shop drawings, product description, operational/owner’s manuals, and specifications for equipment being supplied by the Offeror under this contract.

D. SAFETY AND SITE ACCESS

Contractor shall adhere to the following safety requirements:

1.Contractor shall follow the RSHS and the Service’s facility safety protocols. The RSHS 2014 Edition is available online at: http://www.usbr.gov/safety/RSHS/.
2.OSHA Safety and Health Standards for the Construction Industry 29 CFR Part 1926.

Site Visit: (Tentatively Scheduled) Date: Friday, October 17, 2025 Time: 10:30 a.m.

Location: 500 Lavelle Road Alamogordo, New Mexico 88310

Contractor shall adhere to the following site access requirements:

1.Contractor shall follow USBR Cleaning Manual Inspection and Cleaning Manual for Equipment and Vehicles to Prevent the Spread of Invasive Species (Technical memorandum No. 86-68220-07-05) 2012 Edition available online at: http://www.usbr.gov/mussels/prevention.
2.Contractor shall use existing established access roads and work within established construction boundaries.
3.Do not interfere with work of other contractors or the Government in vicinity, or with reservations made by the Government for use of such land.
4.The BGNDRF access will be granted through the existing gate located along the south side of the facility. BGNDRF operational hours are from 7:30 AM MDT to 4:30 PM MDT Monday through Friday, except on federal holidays. Optional hours of operation may be granted by approval from COR. Coordinate access by contacting the facility manager:

Malynda Cappelle, Facility Manager 500 Lavelle Road Alamogordo, New Mexico 88310

Phone No.:(575) 443-6553
Email:mcappelle@usbr.gov

E. WELL REPAIRS

Offeror shall comply with all state and county codes and permits. Offeror is responsible for all permits required to pull and service water well.

Description of work tasks is to perform a video inspection, replace equipment as necessary, and clean the existing BGNDRF Well No. 2. The well is producing air that is not bleeding off. Previous visits by a local well company have indicated there could be issues with the pump, motor, check valve, or other equipment. Well screen issues could also be present. Expected work needed includes pulling the well pump, injecting cleaning chemical, flushing the well, and performing video inspections before and after the cleaning operations. The pump, motor, check valve, and other appurtenances should be replaced. Well 2 has an estimated diameter of 6-inches and the submersible pump depth should be 159 ft below ground surface (bgs). The well is screened from 90 to 190 ft bgs and static water is around 70 ft bgs. The existing 7.5 hp pump originally flowed at 80 gallons per minute (gpm) but has recently declined to 70-72 gpm with a substantial amount of air. The electrical supply is 480VAC/3phase. The water is brackish with approximately 6,000 mg/L total dissolved solids.

Components of Work. – The following is a short list of the principal work tasks for repairing Well No. 2:

· Coordinate Tag-Out/Lock-Out of pump’s energizing systems with facility manager.

· Remove existing jacketed pipe insulation and, if possible, store for reuse after repairs are completed on the well.

· Pull existing motor and pump assembly for inspection and cleaning. Use existing stainless steel pipe and take caution not to damage existing airline and sound tubing.

· Disconnect pump electrical systems.

· Obtain video of well and provide written report documenting findings. The video must be viewable on a computer CD/DVD drive.

· Install chemical for cleaning and allow to soak per manufacturer suggestions.

· Flush well into BGNDRF evaporation ponds. Coordinate this work with BGNDRF staff.

· Obtain video of well and provide written report documenting findings. The video must be viewable on a computer CD/DVD drive.

· Install new pump, motor, and check valve. Reset well pump assembly using existing airline and sound tubing by lowering into place with new or existing stainless steel pipe. Record depth of well.

· Coordinate Tag-Out/Lock-Out to energize electrical systems to test well pump assembly.

· If pump is operating correctly move to insulation step. If pump assembly is not working correctly, diagnose/troubleshoot problem and repair systems until pump is working correctly.

· Reinstall jacket pipe insulation if possible. If new insulation is required, install equivalent replacement. Insulation specifications can be provided by the COR.

· Clean-up area and leave project site.

F. SITE MAP