DOT_Trenching_and_Backfilling.pdf

PDF 512 KB Posted

Attached to
REPLACEMENT OF EXISTING PLASTIC WATER SERVICES WITH NEW COPPER WATER SERVICES FY27 ROPE FERRY ROAD (STATE ROAD)
Solicitation number
IFB# 26-014
Issued by
New London County, Connecticut

About this file

This is a technical standard sheet document issued by the Connecticut Department of Transportation (CTDOT) that establishes specifications for trenching and backfilling procedures related to electrical conduit installation. The document provides detailed engineering guidance for the proper excavation, placement, and restoration of trenches containing communication cables and related infrastructure. The specifications cover conduit depth requirements (minimum 24 inches), backfill compaction procedures (6-inch lifts using power compaction), warning tape placement, identification post installation with numbered signage, and restoration protocols for disturbed areas. The standard sheet applies to work performed across Connecticut's transportation infrastructure and references CTDOT Standard Specifications sections for additional requirements including concrete sidewalk replacement, seeding in mowed areas, and utility protection measures.

The document establishes mandatory technical requirements for contractors performing trenching work on state transportation projects, including specific material standards such as detectable warning tape in orange (for communication) and red (for power), identification posts constructed from 4-inch by 4-inch pressure-treated wood positioned approximately 24 inches from rigid metal conduit (RMC), and concrete or asphalt overlay specifications to match existing pavement thickness. Contractors must comply with the Call Before You Dig hotline (1-800-922-4455) prior to excavation and follow detailed protocols for crossing existing utilities beneath grade. The standard sheet was submitted and approved by CTDOT's Office of Engineering and is effective as of January 23, 2024, with final approval dated February 21, 2024. This specification applies to the Town of Waterford's water service replacement project on Rope Ferry Road and establishes binding technical requirements for all qualified licensed contractors bidding on related infrastructure work in Connecticut.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CT DOT

COMMUNICATION

CONDUIT

BURIED BELOW

CALL BEFORE

YOU DIG

1 - 800

922 - 4455

XX

OW

SAND

BEVELED END

GROUND LINE

CONDUIT

SAND BACKFILL LEVEL

SUITABLE BACKFILL

SIGN FACE DETAIL

INTERCONNECT TYPICAL CURB CROSSING

M

IN

M

IN

NOTES:

1. RESTORE AREAS DISTURBED BY TRENCH TO ORIGINAL CONDITION.

CONDUIT

NOTES:

1. 4" x 4" NOMINAL, PRESSURE TREATED WOOD POST.

NYLON WASHER ON FACE OF SIGN.

IS GREATER THAN 1500' APART.

36" (MIN)

10' (MIN)

36" (MIN)

6"

2" (MIN)

1¼"

1½"

SIGN FACE ON ALL FOUR SIDES

ATTACH NUMBERS TO SIDE OF POST FACING CONDUIT.

TO TRENCH CONTAINING COMMUNICATION CABLE.

2¾" (TYP)

⅜" (TYP)

½" (TYP)

4" MIN

8" MIN

24"

MAX

12"

T

O

SIGN # 41-4669

4" MIN.

SAW CUT EDGE

6" TO 12"

SAW CUT EDGE

CONDUIT

CONCRETE OVERLAY

EXISTING BITUMINOUS

EXISTING BITUMINOUS OR PCC PAVEMENT

EXISTING BITUMINOUS

T

O

CONCRETE OVERLAY

BEDDING MATERIAL OR SAND

1. TOTAL HOT MIX ASPHALT (HMA) THICKNESS TO MATCH EXISTING BITUMINOUS

SAW CUT EDGE, TACK COAT, AND

SEAL JOINT AFTER PAVING. (TYP)

EXISTING GRADE

2. ATTACH SIGN TO POST WITH ¼" x 1¼" STAINLESS STEEL LAG SCREW WITH

4. INSTALL POST APPROX 24" FROM RMC IN VICINITY OF EACH INTERCONNECT HANDHOLE.

5. INSTALL ADDITIONAL POST(S) WHERE SPACING BETWEEN INTERCONNECT HANDHOLES

6. PERMANENTLY ATTACH STAINLESS STEEL NUMBERS INDICATING DISTANCE IN FEET

SEE NOTE 6 3"

UNDER EXISTING UTILITYCROSSING

30" MAX TYP

CAUTION - CABLE BURIED BELOW

NOTE:

EXISTING UTILITY PIPE OR CONDUIT

NOTES:

DETECTABLE WARNING TAPE

8" MIN.

12" MIN.

NOTES:

CONCRETE AND PORTLAND CEMENT CONCRETE (PCC) THICKNESS.

2. WHEN ALLOWED BY ENGINEER, USE CONTROLLED LOW STRENGTH MATERIAL (CLSM)

AS BEDDING MATERIAL. TOP OF CLSM SHALL BE AT LEAST 20" BELOW SURFACE.

SIDEWALK EARTH

NOTES:

1. IN MOWED AREAS: PLACE TOPSOIL, FERTILIZER, SEED, & MULCH.

4" MIN

REFER TO NOTE 1

GENERAL NOTES:

1. TOP OF CONDUIT AT LEAST 24" DEEP.

2. COMPACT BACKFILL IN 6" LIFTS.

1. WHEN ENCOUNTERED AT APPROXIMATELY THE SAME

DEPTH, CROSS BENEATH.

INTERCONNECT CONDUIT

STANDARD SPECIFICATIONS, SECTION 9.50 OR SEEDING TYPE CALLED OUT ON THE PLANS.

DETECTABLE WARNING TAPE

COMMUNICATION - ORANGE BACKGROUND / BLACK LEGEND

STANDARD SPECIFICATIONS, ARTICLE: 1.05.15

1. TAPE COLORS:

2. PROTECT & SUPPORT EXPOSED EXISTING UTILITY.

HAND COMPACTION NOT PERMITTED.

POWER - RED BACKGROUND / BLACK LEGEND

IDENTIFICATION POST

LEGEND - BLACK (OPAQUE).

3. SIGN COLORS: BACKGROUND - ORANGE (RETROREFLECTIVE)

DETECTABLE

WARNING TAPE

OVERLAYED PORTLAND CEMENT CONCRETE

PAVEMENT - BITUMINOUS CONCRETE OR

12" 12"

BE 4"

MINIMUM COMPACTED PAVEMENT THICKNESS SHALL

S0.375 TRAFFIC LEVEL 2 IN MULTIPLE 2"-3" LIFTS

MATCH EXISTING PAVEMENT THICKNESS USING HMA

COMPACTED IN 4" LIFTS

PROCESSED AGGREGATE BASE MATERIAL

TRANSVERSE ENDS OF THE TRENCH

TRAFFIC LEVEL 2, AND SAWCUT

TRAFFIC LEVEL 2, OR 2" HMA S0.5

MILL 2" THEN PLACE 2" HMA S0.375

TACK COAT EDGES (TYP.)

SAND

WARNING TAPE

SUITABLE BACKFILL

CONDUIT

24"

MAX

8" MIN

4" MIN

T

O

12"

SIDEWALK

NOTES:

1. WHERE CONCRETE SIDEWALK IS DAMAGED OR CUT, REPLACE THE

ENTIRE SECTION BETWEEN JOINTS. REPLACEMENT SIDEWALK IS

PAID FOR UNDER THE ITEM "CONCRETE SIDEWALK".

STANDARD SPECIFICATIONS, SECTIONS 9.21 & 9.22

DETECTABLE

COMPACTED IN 4" LIFTS

GRANULAR FILL SHALL BE

8"

STANDARD SPECIFICATION, SECTION 3.04 AND STANDARD SPECIFICATION, ARTICLE 4.06.03

STANDARD SHEET TITLE: STANDARD SHEET NO.:

CONNECTICUT

D E

P A

R T

M E

N T

O F TRANS

P O

R T

A T I

O N

STATE OF CONNECTICUT

TRANSPORTATION

OF

DEPARTMENT

SIGNATURE BLOCK:

TRENCHING & BACKFILLING, ELECTRICAL CONDUIT

TR-1001_01

NOT TO SCALE

NEWINGTON, CT 06111

2800 BERLIN TURNPIKE

OFFICE OF ENGINEERING

STANDARD SHEET

CTDOT

SUBMITTED BY: APPOVED BY:

LEGEND AS SHOWN ON TRAFFIC CONTROL SIGNAL PLAN:

PROPOSED RMC (RIGID METAL CONDUIT)

SAND

EXISTING RMC (RIGID METAL CONDUIT)

CURB OR EDGE OF ROAD

INTERCONNECT

HANDHOLE

UNPAVED EARTH

22.5°- 48" RADIUS

BITUMINOUS SHOULDER

22.5°- 48" RADIUS 22.5°- 48" RADIUS

22.5°- 48" RADIUS

CONDUIT

CONDUIT

CABLE ITEM.

IDENTIFICATION POSTS WITH SIGNS SHALL BE PAID UNDER THE COMMUNICATION 7.

2024-01-23T08:17:40-0500
Lisa N. Conroy, P.E.
2024-02-21T08:25:47-0500
Matthew C. Blume, P.E., PTOE

File details come from the government source that posted it. Updated .