DOT-ITB-27-2006-JB Addendum 1.pdf

PDF 50 KB Posted

Attached to
FDOT Purchase of New Skid-Mounted Sewer Jetter
Solicitation number
ITB-17455
Issued by
Clay County, Florida

About this file

This Addendum 1 document addresses technical clarifications and bidder questions for the Florida Department of Transportation District Two's ITB DOT-ITB-27-2006-JB for the purchase of one new skid-mounted sewer jetter. The solicitation requires sealed bids due November 23, 2026 at 2:00 p.m., with public bid opening at 2:30 p.m. at the District Two Headquarters in Lake City, Florida. The equipment must be fully assembled and operational as a standalone skid unit, delivered to 710 NW Lake Jeffery Road, Lake City, FL 32055 within 30 calendar days of purchase order issuance, subject to $100 per calendar day liquidated damages for late delivery. The jetter specifications include a minimum 38 HP EFI gasoline engine with electric start (though higher horsepower, dual-engine configurations, and diesel engines are acceptable if they achieve performance requirements), a belt-driven industrial triplex plunger pump rated at minimum 4,000 PSI and 20 GPM, a 220-gallon fresh water tank, and 300 feet of included 1/2-inch sewer hose with nozzles. Bidders must acknowledge receipt of this Addendum to remain responsive, and the Department intends award posting on November 24, 2026.

Pricing is firm, net, and delivered on an F.O.B. destination basis, with a 1% MyFloridaMarketplace transaction fee applied to payments. The purchase is not federally funded, making in-state preference provisions applicable; vendors must complete the In-State Preference Form, and out-of-state bidders must submit written attorney's opinions on their home state's price preferences or face rejection. A 5% in-state preference applies to the lowest responsible and responsive bid from out-of-state vendors if their state offers reciprocal preferences. Equipment must be U.S.-manufactured and include a 90-day warranty against defective materials and workmanship. On-site start-up, operator training, and demonstration are required at delivery, with the Department providing forklift unloading services. Bidders must be registered with MyFloridaMarketplace and the Florida Department of Financial Services, submit electronic W-9 forms, and certify compliance with drug-free workplace, E-Verify, and OSHA requirements, as well as non-appearance on Scrutinized Companies Lists.

View the file

Other files

File Type Posted
DOT-ITB-27-2006-JB.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Florida Department of Transportation

RON DESANTIS

GOVERNOR

1109 South Marion Avenue Lake City, FL 32025-5874

JARED W. PERDUE, P.E.

SECRETARY

Improve Safety, Enhance Mobility, Inspire Innovation www.fdot.gov

DISTRICT TWO

PROCUREMENT OFFICE

ADDENDUM 1

DOT-ITB-27-2006-JB

FDOT Purchase of New Skid-Mounted Sewer Jetter

Addendum No. 1 hereby incorporates the following:

1. Provides Answers to Questions received.

The Bidder must acknowledge receipt of this Addendum by completing and returning to the Procurement Office with its bid package by or before the time and date of the bid opening. Failure to do so may deem the Bidder non-responsive.

Company Name

Signature

Date

Failure to file a protest within the time prescribed in Section 120.57(3), Florida Statutes, or failure to post the bond or other security required by law within the time allowed for filing a bond shall constitute a waiver of proceedings under Chapter 120, Florida Statutes.

Note: All written questions are reproduced in the same format as submitted by the Respondent.

Question Answer

1. Insurance (PO T&Cs, Sec. 4.B & 4.C): For a freight-delivered equipment-only purchase order (drop-shipped via common carrier with no on-site installation), will FDOT waive the General Liability and Workers' Compensation certificate requirements?

1. Certificates are not required to be submitted.

2. Delivery Timeframe (Exhibit A, Sec. III–IV):

What is the required number of calendar days for delivery after Purchase Order issuance before the $100/day liquidated damages apply?

2. 30 Days

3. Sewer Hose & Nozzles (Exhibit A, Item 9):

Does the bid require 300 ft of 1/2" sewer hose and nozzles to be included with the hose reel assembly, or reel capacity only?

3. Bid requires 300 ft of 1/2" sewer hose and nozzles to be included with the hose reel assembly.

4. Engine Horsepower (Exhibit A, Items 1, 4, 5): Exhibit A lists a minimum 38 HP EFI engine alongside a minimum 4,000 PSI / 20 GPM pump. Since "meeting or exceeding" specs are allowed, will FDOT accept a higher-HP EFI engine (e.g., 76–80 HP) if needed to achieve true 4,000 PSI at 20

GPM?

4. FDOT will accept a higher-HP EFI engine (e.g., 76–80 HP) if needed to achieve true 4,000 PSI at

20 GPM.

5. Exact Delivery Address & Off-Loading: What is the exact Lake City street address for delivery, and does FDOT have a forklift/dock on-site to off-load the skid?

5. 710 NW Lake Jeffery Road, Lake City, FL 32055.

We do have a forklift and a loading dock.

6. Delivery location: Please confirm the delivery address for the jetter (FOB destination). Is it the District Two Headquarters at 1109 South Marion Avenue, Lake City, FL 32025, or a different maintenance or facilities yard?

6. 710 NW Lake Jeffery Road, Lake City, FL 32055

7. Delivery time: Exhibit A lists the delivery due date as "Per Purchase Order," and liquidated damages of $100 per calendar day may apply. What delivery time after receipt of the purchase order will the Department require or accept (for example, 60, 90 or 120 days ARO)

7. 30 Days

8. Engine (Item 1): Will a unit with a gasoline EFI engine of more than 38 HP, or a dual-engine configuration, be accepted as "meeting or exceeding" Item 1?

8. Yes

9. Frame finish (Item 17): Will an industrial-grade painted or coated steel frame be accepted in place of a powder-coated frame, if documented as a deviation under Special Condition 12?

9. Yes

10. Hose (Item 9): Item 9 calls for "capacity for 300 ft of 1/2-inch sewer hose." Should the bid price include 300 ft of 1/2-inch hose, or only a reel with that capacity?

10. Bid price should include the hose.

11. Delivery requirements: Does the Department need on-site start-up, operator training or a demonstration at delivery (apart from the alternate-brand demonstration in Special Condition 9)? Does the unit need to be unloaded by the vendor, or will the Department provide a forklift?

11. The Department desires on-site start-up, operator training and a demonstration at delivery.

Department will provide a forklift for unloading.

12. Funding: Is this purchase funded with federal funds? We ask because Special Condition 6 says the in-state preference does not apply to federally funded transportation projects.

12. No. Please complete the In-State Preference Form.

13. Will FDOT accept a factory configuration with two 40 HP EFI gasoline engines if it meets the other requirements, or does FDOT require a single engine?

13. FDOT will accept two 40 HP EFI Engines.

14. Must the pump deliver at least 20 gallons per minute while operating at 4,000 PSI?

14. Yes

15. Will FDOT accept delivery of the fully assembled skid as a standalone unit, or must the supplier also mount or connect it to an FDOT vehicle?

15. FDOT will accept delivery of the fully assembled skid as a standalone unit.

16. Exhibit A: II - 1 - A 38 HP gas engine can not power a pump sufficiently to produce 20 GPM @ 4,000 PSI. Is there a reason we want to go with that low of a HP engine or is that just a minimum and we can provide a larger HP engine? Will FDOT accept a diesel engine option?

16. FDOT will accept a larger HP engine. Diesel is accepted.

17. Exhibit A - II - # 5 - Would FDOT accept 18 GPM flow rate in lieu of 20 GPM?

17. Minimum 20 GPM.

18. Exhibit A - II - # 13 - Would FDOT accept a 200 gallon fresh water tank in lieu of a 220 gallon tank in order to minimize total length?

18. Minimum 220 gallon tank

19. There are no dimension details or requirements. Is this going in the back of a pick up truck or are there any dimension requirements?

19. Dimensions should be such that it can fit on a forklift compatible frame and be placed in a full size truck bed.