DNTS SIR Sect L4 - Offeror Self Assessment Form.xlsx

XLSX spreadsheet 93 KB Posted

Attached to
Screening Information Request (SIR) Dedicated Network Telecommunications System (DNTS) Federal contract opportunity
Solicitation number
693KA8-24-R-00007
Issued by
Department of Transportation Federal Aviation Administration Headquarters

About this file

This document is an offeror self-assessment form for a Dedicated Network Telecommunications System (DNTS) being procured by the Department of Transportation Federal Aviation Administration Headquarters. As indicated in the related federal contract opportunity, the solicitation number is 693KA8-24-R-00007 and is for a DNTS. The self-assessment form contains 182 statements that offerors must address to indicate whether their proposed solution meets the requirements. The statements cover numerous technical requirements for the DNTS such as interfaces, protocols, timing and synchronization, power, environmental conditions, safety, and maintenance. Offerors must fill in the highlighted cells of the form to state whether each requirement is met, and to identify the specific proposed product that fulfills the requirement.

View the file

Other files for this federal contract opportunity

Other files attached to Screening Information Request (SIR) Dedicated Network Telecommunications System (DNTS), newest first.
File Type Posted
693KA8-24-R-00007_Amend_0001.pdf PDF
DNTS SIR Sect C_Amend 1.pdf PDF
DNTS SIR Sect L Att L2_Amend 1.pdf PDF
DNTS SIR Sect J Att J2_Amend 1.pdf PDF
DNTS SIR Sect L_Amend 1.pdf PDF
Telcordia_PUB43801_ChannelBank.pdf PDF
DNTS Final SIR - Vendor QA 2023-12-22.pdf PDF
DNTS SIR Sect H_Amend 1.pdf PDF
DNTS SIR Sect M Att M1_Amend 1.pdf PDF
693KA8-24-R-00007.pdf PDF
DNTS SIR Applicable Documents.zip ZIP file
DNTS SIR Sect F.pdf PDF
DNTS SIR Sect G.pdf PDF
DNTS SIR Sect I.pdf PDF
DNTS SIR Sect C.pdf PDF
DNTS SIR Sect D.pdf PDF
DNTS SIR Sect H.pdf PDF
DNTS SIR Sect J3 - Labor Categories.pdf PDF
DNTS SIR Sect J4 - ISD Process.pdf PDF
DNTS SIR Sect K.pdf PDF
DNTS SIR Sect L3 - WJHTC Access Instructions.pdf PDF
DNTS SIR Sect M1 OCT Plan.pdf PDF
DNTS SIR Sect B.pdf PDF
DNTS SIR Sect J0 - List of Attachment.pdf PDF
DNTS SIR Sect L1 - Resume Template.docx DOCX document
DNTS SIR Sect L5 - Clarfication Form.docx DOCX document
DNTS SIR Sect L8 - Management Capability Form.docx DOCX document
DNTS SIR Sect M.pdf PDF
DNTS SIR Sect E.pdf PDF
DNTS SIR Sect B Price Template.xlsx XLSX spreadsheet
DNTS SIR Sect J1 - FAA-P-2978e.pdf PDF
DNTS SIR Sect J2 - CDRLs and DIDs.pdf PDF
DNTS SIR Sect L.pdf PDF
DNTS SIR Sect L2 - Past Performance Survey.pdf PDF
DNTS SIR Sect L6 - OCT Participation.docx DOCX document
DNTS SIR Sect L7- Sample Testing VRTM.pdf PDF
DNTS SIR Sect M2 - VRTM for Evaluation.pdf PDF
Show all 37

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VRTM

Dedicated Network Telecommunications System (DNTS) SIR # 693KA8-24-R-00007

Attachment L4 - Offeror VRTM Self Assessment Form182Total Shall Statements
Vendor Name:Date Submitted:
182Incomplete
Instructions: Fill in all highlighted cells as follows:182
Column A: Provide YES/NO answers to the requirements
Column B: Identify the specific proposed unit(s) (manufacturer and part number) that fulfills this requirement
Column AColumn B
Shall NumberFAA-P-2978
Par #RequirementYes/No?Identify proposed DNTS unit(s) that meet(s) this requirement
13.1.aThe Dedicated Network Telecommunications System (DNTS) equipment shall(1) be scalable with options to configure any mix of interfaces from sections 3.1.2, 3.1.3 and/or Section 3.1.4 up to the aggregate capacity of the specified SONET Optical Interface.
23.1.bThe DNTS shall(2) provide an optional configuration providing a limited set of capabilities to include SONET OC-3, 100 BaseT, and any mix of Low Speed interfaces from 3.1.4.
33.1.1.aThe DNTS shall(3) be compliant with Telcordia GR-253 and ANSI T1.105 SONET specifications.
43.1.1.bThe DNTS shall(4) have optional configurations to function at the SONET OC-3 line rate.
53.1.1cThe DNTS shall(5) have optional configurations to function at the SONET OC-12 line rate.
63.1.1.dThe DNTS shall(6) have optional configurations to function at the SONET OC-48 line rate.
73.1.1.eThe DNTS shall(7) support transmission over single-mode fiber as specified in FAA-E-2761c.
83.1.1.fThe DNTS shall(8) support UPSR as specified in GR-1400.
93.1.1.gThe DNTS shall(9) operate with one or both optical transmitter/receivers enabled.
103.1.1.hWhen both transmitter/receivers are enabled the DNTS shall(10) provide for auto reconfiguration in accordance with UPSR.
113.1.1.iIn the event of loss of physical layer connectivity on one path between nodes with redundant fiber paths, the system shall(11) restore communications within 60 milliseconds.
123.1.1.jThe transmitter’s peak emission wavelength shall(12) be 1310 nm ± 50 nm.
133.1.1.k.1The dynamic range of the transmitter/receiver shall(13) not be less than 13 dB for short or intermediate reach transmitter/receivers.
143.1.1.k.2The dynamic range of the transmitter/receivers shall(14) not be less than 25 dB for long reach transmitter/receivers.
153.1.1.k.3The maximum transmitter optical power output shall(15) not exceed the maximum allowable input power level of the receiver for short and intermediate reach transmitters.
163.1.2.aThe DNTS shall(16) provide Structure-Agnostic Time Division Multiplexing (TDM) over Packet (SAToP) in accordance with IETF RFC 4553.
173.1.2.bThe DNTS shall(17) provide Circuit Emulation Service over Ethernet (CESoETH) in accordance with MEF 3
183.1.2.cThe DNTS shall(18) provide Circuit Emulation Service over Ethernet (CESoETH) in accordance with MEF 8.
193.1.2.dThe DNTS shall(19) provide Circuit Emulation Service over Packet Switched Network (CESoPSN) in accordance with IETF RFC 5086.
203.1.2.eThe DNTS shall(20) provide Multi-Protocol Label Switching – Transport Profile (MPLS-TP) in accordance with IETF RFC 5654.
213.1.2.fThe DNTS shall(21) provide Ethernet Linear Protection Switching (ELPS) in accordance with ITU-T G.8031.
223.1.2.gThe DNTS shall(22) provide Ethernet Ring Protection Switching (ERPS) in accordance with ITU-T G.8032.
233.1.2.hThe DNTS shall(23) provide Operation, Administration and Maintenance (OAM) in accordance with IEEE 802.3-2018.
243.1.2.iThe DNTS shall(24) have the option to terminate a minimum of ten IEEE 802.3 10/100/1000BaseT circuits, each circuit independently configurable as Layer 1 or Layer 2.
253.1.2.jThe DNTS shall(25) have optional configurations to provide a minimum of four Optical Gigabit Ethernet (GbE) circuits.
263.1.2.kThe DNTS shall(26) provide MSTP in accordance with IEEE 802.1q Clause 13.
273.1.2.lThe DNTS shall(27) provide VLAN-aware bridging capability in accordance with IEEE 802.1q Clause 5.
283.1.2.mShall(28) Reserved
293.1.2.nThe DNTS shall(29) provide Virtual Bridged Local Area Networks in accordance with IEEE 802.1q Clause 7.
303.1.2.oThe DNTS shall(30) provide Hierarchical Quality of Service (QoS) in accordance with IEEE 802.1p.
313.1.2.pThe DNTS shall(31) provide Unicast to Multicast conversion using Protocol Independent Multicast – Sparse Mode (PIM-SM) in accordance with IETF RFC 7761.
323.1.2.qThe DNTS shall(32) support IPv6 for management functions and interfaces in accordance with IETF RFC 8200 and 8504.
333.1.2.rThe DNTS shall(33) support IPv6 for packet transport in accordance with IETF RFC 8200 and 8504.
343.1.3.1The DNTS shall(34) terminate a minimum of two ITU-T G.991.2 compliant SHDSL circuits.
353.1.3.2.aThe DNTS shall(35) terminate a minimum of four ANSI T1.403 compliant DS1 circuits.
363.1.3.2.bThe T1/DS1 interfaces shall(36) provide Extended Super Frame (ESF) format as defined by ANSI T1.403.
373.1.3.2.cThe T1/DS1 interfaces shall(37) provide Bipolar with 8-zero substitution (B8ZS) line code as defined by ANSI T1.403.
383.1.4.1.aThe DNTS shall(38) provide ANSI/EIA/TIA-232F Type D compliant interfaces supporting Synchronous and Asynchronous communications.
393.1.4.1.bThe DNTS ANSI/EIA/TIA-232F Interface Type D shall(39) be configurable to allow for any combination of control signals to be forced on, enabled or disabled.
403.1.4.1.cThe DNTS ANSI/EIA/TIA-232F interface shall(40) use the 25-pin connector where Transmit Signal Element Timing (DTE – pin 24) is passed through the DNTS independent of the DNTS Timing.
413.1.4.2.aThe DNTS shall(41) provide ANSI/EIA/TIA-422/530 compliant interfaces supporting Synchronous and Asynchronous communications.
423.1.4.2.bThe DNTS shall(42) provide ANSI/EIA/TIA-422 compliant interfaces using the 25 pin connector (EIA-530) where Transmit Signal Element Timing (DTE Source – pins 11 and 24) is passed through the DNTS independent of the DNTS Timing.
433.1.4.3The DNTS shall(43) provide Digital Data Service (DDS) interfaces as defined by Telcordia PUB 62310.
443.1.4.4.aThe DNTS shall(44) bridge one simplex ANSI/EIA/TIA-232F synchronous input to a minimum of five simplex ANSI/EIA/TIA-232F synchronous output circuits on the same DNTS (Figure 3-1).
453.1.4.4.bThe DNTS shall(45) bridge one simplex ANSI/EIA/TIA-232F synchronous input over the network to output a minimum of 5 simplex ANSI/EIA/TIA-232F synchronous output circuits on any node in the same ring (Figure 3-2).
463.1.4.5.aThe DNTS shall(46) provide Ear and Mouth (E&M) Voice Frequency interfaces as defined by Telcordia PUB 43801.
473.1.4.5.bThe DNTS shall(47) provide Foreign Exchange Service (FXS) Voice Frequency interfaces as defined by Telcordia PUB 43801.
483.1.4.5.cThe DNTS shall(48) provide Foreign Exchange Office (FXO) Voice Frequency interfaces as defined by Telcordia PUB 43801.
493.1.4.5.dThe DNTS shall(49) provide Private Line Automatic Ring down (PLAR) Voice Frequency interfaces as defined by Telcordia PUB 43801.
503.1.4.5.e.1FXO and FXS interfaces shall(50) be configurable to 600 or 900 ohm impedance.
513.1.4.5.e.2E&M interface shall(51) provide 600 ohm impedance.
523.1.4.5.fThe audio transmission level for the E&M interfaces listed below shall(52) be adjustable over a range of –16.0 dBm to +7 dBm for 2-Wire circuits.
533.1.4.5.gThe audio transmission level for the E&M interfaces listed below shall(53) be adjustable over a range of –16.0 dBm to +7 dBm for 4-Wire circuits.
543.1.4.5.h.1The E&M interface shall(54) provide Type I signaling as defined by SR-2275.
553.1.4.5.h.2The E&M interface shall(55) provide Type II signaling as defined by SR-2275.
563.1.4.5.h.3The E&M interface shall(56) provide Type III signaling as defined by SR-2275.
573.1.4.5.h.44) The E&M interface shall(57) provide Type IV signaling as defined by SR-2275.
583.1.4.5.h.5The E&M interface shall(58) provide Type V signaling as defined by SR-2275.
593.1.4.5.i.1The Voice Frequency Interfaces attenuation distortion shall(59) have a tolerance of -0.5 to 1.5 dB in the frequency range of 404 – 2804 Hz.
603.1.4.5.i.2The Voice Frequency Interfaces attenuation distortion shall(60) have a tolerance of -0.5 to 4.5 dB in the frequency ranges of 304 – 403 and 2805 – 3004 Hz.
613.1.4.5.jThe frequency shift for the Voice Frequency Interfaces shall(61) be less than or equal to 1.0 Hz.
623.1.4.5.kThe envelope delay distortion for the Voice Frequency Interfaces shall(62) be less than or equal to 650 μsec.
633.1.4.5.l.1The phase jitter for the Voice Frequency Interfaces shall(63) be less than or equal to 8° in the frequency range of 4 – 300 Hz.
643.1.4.5.l.2The phase jitter for the Voice Frequency Interfaces shall(64) be less than or equal to 3° in the frequency range of 20 – 300 Hz.
653.1.4.6.aThe DNTS shall(65) provide dry contact with output current rating of ≥ 1A
663.1.5.aThe DNTS system shall(66) provide an optional Primary Reference Source (Stratum 1) timing and synchronization compatible with the DNTS equipment and in accordance with:

1) ATIS-0900001

2) ATIS-0900101.2013

3) ATIS-0900105.09.2013

673.1.5.bThe DNTS shall(67) include a Stratum 3 or better internal clock.
683.1.5.cThe DNTS shall(68) accept timing from a Building Integrated Timing System (BITS) interface per GR-1244.
693.1.5.dThe DNTS shall(69) accept timing from a OC-N interface per GR-1244.
703.1.5.eThe DNTS shall(70) accept timing from an incoming DS1 interface per GR-1244.
713.1.5.fThe DNTS DS1 interfaces shall(71) be synchronized with the selected timing source.
723.1.6.aThe DNTS shall(72) synchronize internal clocks every 24 hours with a common time source.
733.1.6.bThe DNTS shall(73) synchronize internal clocks to the common time source when the time difference is greater than 6 seconds.
743.1.6.cThe DNTS shall(74) support NTP.
753.1.7It shall(75) be possible to network, in a ring configuration via optical fiber, as few as two and as many as sixteen DNTSs.
763.1.8.aThe DNTS shall(76) be configurable, using an IEEE 802.3 10/100/1000BaseT interface, by the FAA without manufacturer intervention.
773.1.8.bThe DNTS shall(77) provide for additional circuits to be added by the FAA without manufacturer intervention.
783.1.9.aIf the DNTS is software configurable, the configuration data shall(78) be preserved within the DNTS such that no single module failure will require the reentry of configuration files.
793.1.9.bThe DNTS shall(79) internally preserve configuration data where in the event of a power failure the DNTS will fully restore services when power is restored.
803.1.9.cThe DNTS shall(80) allow for the storage of configuration data to an external device that is not part of the DNTS, such as a hard drive on a laptop, for backup and restoral purposes.
813.1.9.dThe DNTS shall(81) be capable of restoring configuration data from an external device.
823.1.10The nominal BER attributable to the DNTS shall(82) be 1 x 10-9 or better.
833.1.11The DNTS shall(83) be fully functional, with all interfaces working within normal operating ranges, when the BER of the transport layer is no worse than 1 x 10-6.
843.1.12.aThe DNTS shall(84) include built in self-test (BIST) functionality and provide the results via SNMP, traps and querries
853.1.12.bBIST data shall(85) be identified by the network address of the unit to which it applies.
863.1.12.cThe DNTS shall(86) have ability to discover node adjacencies.
873.1.12.dThe DNTS shall(87) failover to alternate processing equipment for any failure that affects system operations preserving normal or degraded operations.
883.1.13.aThe DNTS shall(88) provide status via SNMP V3, both traps and SNMP Queries.
893.1.13.bThe DNTS shall(89) indicate a minor alarm when a failure in any power supply module, in which the failure does not cause an outage.
903.1.13.cThe DNTS BIST shall(90) provide status when optical received power is insufficient to sustain a BER of 1x10-6 or better.
913.1.13.dThe DNTS BIST shall(91) indicate an I/O module failure status.
923.1.13.eThe DNTS BIST shall(92) indicate a Node failure status.
933.1.13.fThe DNTS BIST shall(93) indicate a Loss of Signal (LOS) status.
943.1.13.gThe DNTS BIST shall(94) indicate a Loss of Frame (LOF) status.
953.1.13.hThe DNTS BIST shall(95) indicate an Alarm Indication Signal (AIS) status.
963.1.13.jAs a minimum, the DNTS shall(96) accept, via contact closures, major and minor alarm inputs from external equipment connected to it.
973.1.14.aThe DNTS shall(97) generate audit logs for both Operating System and Application level events for local, non-local, and remote sessions. The following minimum events must be captured and recorded:

(1) Resource degradation alerts (e.g., 100% utilization, disk space full, volume full),

(2) Login and logout, successful and unsuccessful,

(3) Account creation/modification and permissions or configuration changes,

(4) Administrator level activities,

(5) Startup/Shutdown of System/Services/processes,

(6) Access to privileged functions (e.g., setting auditable event and intrusion detection devices) including maintenance,

(7) Results from malicious code protection (as capable),

(8) Access control list denials (as capable), and

(9) IDS signature based attacks (as capable).

983.1.14.bThe DNTS shall(98) generate audit records that contain the type of event, date, time, system source (asset name and IP address) where the event occurred, user/subject identification, outcome of the event (success/failure), and session ID if applicable; but do not contain sensitive information, such as passwords, actual system data, or privacy information.
993.1.14.cThe DNTS shall(99) allocate sufficient storage capacity to store 14 days of security-relevant audit records in online storage, and configure the system auditing capacity to reduce the likelihood of audit record storage capacity being exceeded (e.g., provide 25% capacity above estimated need).
1003.1.14.dThe DNTS shall(100) provide audit record warning notifications in accordance with defined thresholds. Systems must implement at least three levels of warning notifications (e.g., 50%, 75%, 90%).
1013.1.14.eThe DNTS shall(101) not alter the original content or time ordering of audit records.
1023.1.14.fThe DNTS shall (102) provide accurate time stamps (including date, time, and UTC offset) in audit records.
1033.1.14.gThe DNTS shall(103) time stamp audit records to within one second.
1043.1.14.hThe DNTS shall(104) protect audit information and audit tools from unauthorized access, modification, and deletion by restricting access privileges to individuals who are responsible for performing auditing functions.
1053.1.14.iThe DNTS shall(105) be able to back up its audit records at least once per 24 hour period onto a syslog server.
1063.1.14.jThe DNTS shall(106) use cryptographic mechanisms to protect the integrity of audit record information and auditing tools.
1073.1.15.1.aThe DNTS shall(107) be able to integrate with automated mechanisms (e.g., Active Directory, TACACS, LDAP, RADIUS) to support the management (e.g., establishing, activating, modifying, deactivating, reviewing, and monitoring accounts; expiring unused accounts) of system accounts.
1083.1.15.1.bThe DNTS shall(108) automatically disable or remove temporary and emergency user accounts within 24 hours after the need for the account is no longer valid, as determined by a system administrator.
1093.1.15.1.cThe DNTS shall(109) automatically disable inactive user accounts (Operating System and Application) after 90 days of inactivity.
1103.1.15.1.dThe DNTS shall(110) restrict account privileges to system administration, security administration, generic user, or super user.
1113.1.15.1.eThe DNTS shall(111) prevent non-privileged users from executing privileged functions including disabling, circumventing, or altering implemented security safeguards/countermeasures
1123.1.15.1.fThe DNTS shall(112) enforce a limit of 5 consecutive invalid login attempts within a 15 minute period.
1133.1.15.1.gThe DNTS shall(113) be configured to either automatically:

1) Lock the account for 15 minutes, or

2) Lock the account until released by an administrator, when the maximum number of unsuccessful attempts is exceeded regardless of whether the login occurs via a local or network connection.

1143.1.15.1.hThe DNTS shall(114) be configured to restrict logical access to the specific users that are responsible for implementing configuration changes through roles and/or access privileges. Audit functions must be configured to log all configuration changes and privileged user access.
1153.1.15.1.iThe DNTS shall(115) perform the following verification and notification functions:

1) Verifies the correct operation of access controls and auditing functions;

2) Performs this verification upon system start-up, restart, and upon command by an authorized privileged user at least every 90 days;

3) Notifies system and/or security personnel of failed security verification tests; and

4) Implement the actions performed upon notification of failed security verification, including one of the following: system shut down, system restart, or notify system maintenance/security personnel.

1163.1.15.1.jThe DNTS shall(116) support Network Access Controls (NAC) (e.g., NIC address, host name), Active Directory, and/or group policy for connecting devices on the network.
1173.1.15.1.kThe DNTS shall(117) generate error messages without revealing, in error logs or administrative messages, sensitive information (e.g., passwords, PII) or information that could be exploited by adversaries.
1183.1.15.1.lThe DNTS shall(118) restrict access to error messages and error logs only to authorized personnel via either physical or logical access controls.
1193.1.15.2.aThe DNTS shall(119) use multifactor authentication for remote and local access to privileged and non-privileged user accounts.
1201.1.15.2.bThe DNTS shall(120) implement replay-resistant authentication mechanisms for network access to privileged and non-privileged accounts.
1213.1.15.2.cThe DNTS shall(121) require passwords with the following characteristics: a minimum of 8 characters with no complexity requirements when MFA is also employed, and a minimum of 12 characters requiring at least one non-alphabetic character otherwise. This follows CIS guidelines.
1223.1.15.2.dThe DNTS shall(122) support annual password expiration following CIS guidelines.
1233.1.15.2.eThe DNTS shall(123) protect authenticator content (passwords, PIN, community strings) from unauthorized disclosure and modification in storage and in transmission. Authenticator content must use encryption for protection while in storage. Protection of authenticators in transmission may use either encryption or through isolation using a dedicated connection.
1243.1.15.2.fThe DNTS shall(124) enforce password lifetime restrictions to be a minimum of 2 days between password changes.
1253.1.15.2.gThe DNTS shall(125) enforce a 24 password change cycle reuse restriction.
1263.1.15.2.hThe DNTS shall(126) enforce an immediate (at first login) password change when a temporary password is issued for account creation and for lost/compromised password replacement.
1273.1.15.2.iThe DNTS shall(127) obscure feedback of authentication information (e.g., masking passwords, prohibit passwords from being displayed) during the authentication process to protect the information from possible unauthorized exploitation/use.
1283.1.15.2.jThe DNTS shall(128) only implement cryptographic modules that are FIPS 140-2 level 1 compliant for authentication.
1293.1.15.3.aThe DNTS shall(129) display a warning banner in accordance with FAA Order 1370.121, FAA Information Security and Privacy Program and Policy, as part of every system login.
1303.1.15.3.bThe DNTS shall(130) display the notification message or banner on the screen until users take explicit actions to acknowledge the notification.
1313.1.15.3.cThe DNTS shall (131) prevent further access to the system by initiating a session lock (e.g., password protected screen saver), which conceals information, for local access sessions after 15 minutes of inactivity.
1323.1.15.3.dThe DNTS shall(132) retain the session lock until the user re-authenticates.
1333.1.15.3.eThe DNTS shall(133) automatically terminate a user initiated logical session after 30 minutes of user inactivity.
1343.1.16.1.a.iThe DNTS shall(134) satisfy all requirements herein, in accordance with the input power conditions as specified in FAA-G-2100j, Section 3.1.1.6a, c and d. Input Power Conditions for AC 120 Volts 1 Phase.
1353.1.16.1.a.iiThe DNTS shall(135) operate within the range of -38.4 Volts DC to -57.6 Volts DC with < 5% AC Ripple.
1363.1.16.1.a.iiiThe DNTS shall(136) operate within the range of 19.2 Volts DC to 28.8 Volts DC with < 5% AC Ripple.
1373.1.16.1.bIn the instance that the primary input power parameters are out of the specified nominal voltage range, due to a power event or a loss of power, the DNTS shall(137) satisfy one of the following criteria:

1) Restore operation within six seconds (once input power returns to defined parameters), OR

2) Maintain operations for a minimum of fifteen seconds, after the power event or loss of power.

138 3.1.16.1.c The DNTS shall(138) have built in redundant power inputs.

1393.1.16.1.dThe DNTS equipment shall(139) incorporate reverse polarity protection to prevent damage to the DNTS equipment if the polarity of the DC input voltage is reversed.
1403.1.16.1.eThe DNTS solution shall(140) provide a lead acid battery backup power option capable of providing power to the DNTS for a minimum of 8 hours.
1413.1.16.2.aThe DNTS equipment shall(141) meet the inrush current requirements listed in section 3.1.1.2.3 of FAA-G-2100j.
1423.1.16.2.bThe DNTS equipment shall(142) meet the harmonic content requirements listed in section 3.1.1.2.1 of FAA-G-2100j.
1433.1.16.2.cThe DNTS equipment shall(143) meet the power factor requirements listed in section 3.1.1.2.2 of FAA-G-2100j.
1443.1.16.3.aCurrent overload protection for the DNTS equipment shall(144) be provided by fuses, circuit breakers, or other protective devices for primary input AC and DC circuits.
1453.1.16.3.bOvercurrent devices shall(145) be protected from damage due to a loss of power (AC or DC).
1463.1.16.3.cOvercurrent protective devices shall(146) detect fault currents and provide fault isolation.
1473.1.16.3.dSeries combination system overcurrent protection shall(147) not be permitted.
1483.1.16.4All DNTS equipment shall(148) withstand static discharges as specified in FAA-G-2100j, paragraph 3.2.6, without resultant unit, assembly, or component failures.
1493.1.16.5.aThe loss or variance of input voltage, including loss of voltage caused by activation of circuit protector devices, shall(149) not cause or induce any damage to any component in the DNTS or other interfacing equipment.
1503.1.16.5.bThe loss or variance of input voltage, including loss of voltage caused by activation of circuit protector devices, shall(150) not result in loss of settings or data.
1513.1.17Upon application of power to a node in a loop, end-to-end connectivity shall(151) be restored in less than 5 minutes.
1523.1.18.aThe DNTS shall(152) be mountable in a 19 inch (482.6 mm) wide rack or cabinet compliant with EIA-310d section 1.
1533.1.18.bThe DNTS shall(153) be mountable on a wall.
1543.1.19The DNTS solution including all required external equipment and required ventilation shall(154) not exceed 18 inches in depth and 14.0 inches (eight 1.75-inch rack units) in height.
1553.1.20The DNTS shall(155) meet or exceed NEBS level 3 requirements for operating temperature and humidity as specified in Telcordia SR-3580.
1563.1.21The DNTS equipment shall(156) meet or exceed the NEBS level 3 requirements for altitude including criterion [76] in GR-63c.
1573.1.22The DNTS equipment shall(157) meet or exceed the NEBS level 3 requirements for storage, transportation and handling temperature and humidity specified in Telcordia GR-63c criterion [69-71].
1583.1.23The DNTS equipment shall(158) meet or exceed the NEBS level 3 requirements for storage, transportation and handling shock and vibration specified in Telcordia GR-63c criterion [107-109, 124].
1593.1.24The DNTS equipment shall(159) meet or exceed the criteria for Earthquake zone 4 as specified in in Telcordia SR-3580.
1603.1.25The DNTS equipment shall(160) meet the NEBS level 3 criteria for ESD and EMI specified in Telcordia SR-3580.
1613.1.26The DNTS equipment shall(161) meet the NEBS level 3 criteria for Thermal Heat Dissipation specified in Telcordia SR-3580.
1623.1.27The DNTS equipment shall(162) meet the NEBS level 3 criteria for Acoustic Noise specified in Telcordia SR-3580.
1633.2.1After fabrication, parts and assembled equipment shall(163), be cleaned of smudges; loose, spattered, or excess solder; weld metal, metal chips and mold release agents; or any other foreign material that might detract from the intended operation, function, or appearance of the equipment.
1643.2.2Screws, nuts and bolts shall(164) show no evidence of cross threading, mutilation, or detrimental or hazardous burrs, and be firmly secured.
1653.2.3Wires and cables shall(165) be positioned or protected to avoid contact with rough or irregular surfaces or sharp edges, to avoid damage to conductors or adjacent parts.
1663.2.4.aShielding on wires and cables shall(166) be secured in a manner that will prevent it from contacting or shorting exposed current-carrying parts.
1673.2.4.bThe ends of the shielding or braid shall(167) be secured to prevent fraying.
1683.2.5.aThe specifications of all materials and parts shall(168) have been derated to ensure that the equipment will operate as intended over the full range of environmental and power conditions.
1693.2.5.bThe DNTS shall(169) be either fabricated from fungus-inert materials or conformably coated to provide an effective fungus resistant barrier.
1703.2.6All metal surfaces on cabinetry, panels, and structural parts shall(170) be painted, plated, or anodized to provide protection from the environment.
1713.3.1The MTBF for an LRU within the DNTS, including built-in test equipment, shall(171) not be less than 50,000 hours.
1723.3.2The MTTR shall(172) not exceed 0.5 hours.
1733.3.3Preventive maintenance shall(173) not be required.
1743.3.4The equipment shall(174) be maintainable using standard commercially available equipment.
1753.4.aAn equipment malfunction shall(175) in no way contribute to the destruction of the equipment or any part of its environment.
1763.4.bSafety shall(176) conform to the requirements of FAA-G-2100j, section 3.3.5, and associated subsections.
1773.4.cAny exposed or accessible area of the DNTS equipment that could pose a thermal contact hazard, as defined in 2016 FAA HF-STD-001b, section 5.10.10.1, shall (177) be clearly labeled on the top of the LRU as a Thermal Contact Hazard.
1783.4.dLaser equipment and system design, installation, and written operational and maintenance procedures shall(178) conform to 21CFR1040, Food and Drug Administration, Department of Health and Human Services, Part 1040 Performance Standards for Light-Emitting Products.
1793.4.eThe exact weight of the LRU shall(179) be clearly labeled on the top of the LRU.
1803.5.aThe DNTS grounding requirements shall(180) be as specified in FAA-STD-019F, sections 4.8, 5.6.5, 5.6.6, and their associated subsections.
1813.5.bThe DNTS bonding requirements shall(181) be as specified in FAA-STD-019F, section 4.2, and its associated Subsections.
1823.5.cThe DNTS shielding protection requirements shall(182) be as specified in FAA-STD-019F, section 4.8, 5.6.7, and their associated subsections.