Dixon_Corp_Yard_Phase_2_Report.pdf
PDF 10 MB Posted
- Solicitation number
- 909-1125-27
- Issued by
- Trinity County, California
About this file
This Phase II Environmental Site Assessment (ESA) report was prepared by Cameron-Cole, LLC for the County of Solano regarding the approximately 1.58-acre Dixon Corporation Yard property located at 580 North First Street in Dixon, California (Assessor's Parcel Number 011-506-0140). The assessment was conducted in response to findings from a Phase I ESA completed on September 12, 2024, and includes results from soil, groundwater, and soil gas sampling activities. The site is currently owned by Solano County and utilized by the County Department of Agriculture and Department of Public Works for office space, equipment storage, vehicle parking, and bulk material storage. The Phase II investigation scope included soil sampling at multiple depths, groundwater sampling at 40 feet below ground surface, and installation and sampling of 11 dual-nested soil gas wells at depths of 5 and 15 feet. All drilling activities were conducted under permit approval from the Solano County Environmental Health Division, with underground service alerts and professional utility clearance completed prior to work commencing in February 2025.
The investigation evaluated two recognized environmental conditions identified in the Phase I: potential groundwater contamination from an off-site source to the north (UnoCal Bulk Plant #0161) and de minimis surface staining in the vehicle storage area. Results indicated that diesel-range organics (TPH-d) were detected above screening levels in one surface soil sample (1,100 mg/kg) in the southern storage area, benzene was detected above screening levels in soil gas at two locations (26 and 12 micrograms per cubic meter), and no volatile organic compounds or petroleum hydrocarbons were detected in groundwater samples. The report concludes that detected soil impacts are localized and likely represent small surface spills from parked vehicles, that no further groundwater action is warranted, and that detected benzene in soil gas represents residual contamination from the upgradient property with no continuing source, thus warranting no further corrective action. The future site use is anticipated to be short-term housing for agricultural staff, and all environmental screening levels were applied using residential land use criteria.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PHASE II INVESTIGATION REPORT
580 NORTH FIRST STREET
DIXON, CA
Prepared For:
Mr. Jason Brandman
FirstCarbon Solutions, Inc.
2999 Oak Road, Suite 290
Walnut Creek, CA 94597
AND
Ms. Misty Kaltreider, PG, CEG
Solano County Department of Resource Management
675 Texas Street, Suite 5500
Fairfield, CA 94533
Prepared by:
2236 Mariner Square Drive, Suite #500
Alameda, California 94501
May 23rd, 2025
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 SITE DESCRIPTION
1.2 BACKGROUND AND POTENTIAL ENVIRONMENTAL CONTAMINATION
1.3 PHASE II ESA SCOPE OF WORK
2.0 SAMPLING METHODS
2.1.1 SOIL GAS WELL INSTALLATION
2.1.2 SOIL SAMPLING PROCEDURES
2.1.3 GROUNDWATER SAMPLING PROCEDURES
2.1.4 SOIL GAS LEAK TESTING AND SAMPLING PROCEDURE
2.2 QUALITY ASSURANCE AND QUALITY CONTROL
3.0 RESULTS
3.1 SCREENING LEVEL SELECTION
3.2 SOIL RESULTS
3.3 GROUNDWATER RESULTS
3.4 SOIL GAS RESULTS
4.0 CONCLUSIONS AND RECOMMENDATIONS
4.1 SOIL RESULTS
4.2 GROUNDWATER RESULTS
4.3 SOIL GAS RESULTS
5.0 REFERENCES
LIST OF FIGURES
Figure 1 Regional Location Map
Figure 2 Site Map
Figure 3 Site Map with Compound Exceedances
LIST OF TABLES
Table 1 Environmental Screening Levels: Soil and Groundwater
Table 2 Environmental Screening Levels: Soil Gas
Table 3 Soil Sampling Results
Table 4 Groundwater Sampling Results
Table 5 Soil Gas Sampling Results
LIST OF APPENDICES
Appendix A Subsurface Boring Permit
Appendix B Subsurface Boring Logs
Appendix C Helium Shroud Method
Appendix D Sampling Event Data Sheets
Appendix E Laboratory Reports
1.0 INTRODUCTION
This report presents the results of the Phase II Environmental Site Assessment (ESA) performed by Cameron-Cole, LLC (Cameron Cole) for an approximately 1.58-acre property located at 580 North First Street, Dixon, Solano County, California (the Site), also identified by Solano County assessor’s parcel number (APN) 011-506-0140. The Phase II investigation was performed in response to the Phase I Environmental Site Assessment prepared by Cameron-Cole on September 12th, 2024. This report includes the results of all sampling conducted pursuant to the findings of the Phase I ESA.
1.1 Site Description
The Site consists of one parcel located at 580 North First Street in Dixon, Solano County, California, and it is currently owned by the County of Solano. The Site is also identified by Solano County assessor’s parcel number 011-506-0140. A site location map is provided as Figure 1 and a regional vicinity map as Figure 2.
The Site is currently occupied by two structures and open gravel lot areas which are used for equipment and bulk material storage. The Site is bounded by East F Street to the north and beyond that a commercial property occupied by a towing company, a commercial property occupied by an auto glass facility to the east, a commercial property occupied by a towing business to the south, and North 1st street to the west. The vicinity around the Site is generally occupied by industrial and commercial properties occupied by businesses including but not limited to towing businesses, automotive repair, and manufacturing facilities. The Site is generally flat with a minor slope toward the east and sits at approximately 60-feet above mean sea level (ft msl).
At the time of this assessment, the Site was being used by the Solano County Department of Agriculture as well as the Solano County Department of Public Works. The nature of the property is mixed use, including office space, storage of equipment including heavy equipment, vehicles, tools, and other materials, and the bulk storage of fill materials including but potentially not limited to soils, gravel, and mulch.
The Site is currently occupied by two structures. Among these is one smaller, approximately 1,000-square foot (sq ft) structure near the northern boundary of the Site along East F Street, which is currently used as office space by the Solano County Department of Agriculture. An additional structure is present to the south in the central portion of the site. It consists of an approximately 1,500-square foot interior space which is used for the storage of hand tools, a workshop area, and environmental sample storage by the Department of Agriculture. The remainder of the structure consists of a covered awning area which is used to store vehicles and heavy equipment. The remainder of the site consists of vehicle and bulk storage areas including an open lot toward the eastern edge of the Site where large mounds of materials including gravel, dirt, and mulch can be stored. Vehicle access is provided to the Site by a driveway from East F Street which is secured by a locked gate. Former AST stands were observed to the east of the larger structure, while the tanks have been removed, the former tank stand remains present.
1.2 Background and Potential Environmental Contamination
Two underground storage tanks (USTs) have historically been operated at the Site. The USTs were installed in 1975 and consisted of two 2,000-gallon tanks for the storage of gasoline and diesel fuel, respectively. Records provided by the County of Solano indicate the USTs were removed on March 21st, 1990. Soil sampling conducted during the removal of the tanks did not contain any detectable amount of total petroleum hydrocarbons (TPH) as gasoline (TPH-g), TPH as diesel (TPH-d), or
BTEX.
The adjacent property located north of the Site across East F Street at 129 East F Street is identified in the State Water Resources Control Board (SWRCB) GeoTracker web application as UnoCal Bulk Plant #0161. Details regarding site history include the installation of numerous ASTs and USTs between 1918 and 1987. These tanks contained various contents including kerosene, ethyl, “white magic”, 76 gasoline, distillate, royal 76 gasoline, super 76 gasoline, diesel, 76 unifuel, heating oil, stove oil, regular unleaded, and super unleaded. In May 1995, four 20,000-gallon USTs were removed, and soil samples were collected from the sidewall of the UST pit. Results from these samples included detectable concentrations of TPH-g, TPH-d, and lead. It was determined groundwater sampling was necessary to evaluate the impact to groundwater from the site. A Workplan for a Limited Subsurface Investigation was prepared by GeoStrategies on July 18th, 1995. In February 1998 Gettler-Ryan Inc.
submitted a Limited Subsurface Investigation and File Review for UnoCal Bulk Plant No. 0161. This report details activities conducted including a subsurface anomaly scan to ensure no USTs persisted and a GeoProbe survey to install nine borings to groundwater (at approximately 27 feet below ground surface [ft bgs]), with one groundwater and one vadose zone soil sample taken from each boring.
Results from these samples included concentrations as high as 26-parts per million (ppm) of TPH-g in groundwater and 3,100-ppm of TPH-g in soil and 37-ppm of benzene.
To further assess these conditions at the adjacent property, monitoring wells were installed, and installation details were summarized in the Monitoring Well Installation Report published by Gettler- Ryan Inc. on August 27th, 1998. Five monitoring wells were installed at the property to monitor groundwater which was encountered between 9 and 24-ft bgs. During installation, 15 soil samples were collected from the borings, one composite sample from the soil cuttings, and five groundwater samples. Four soil samples contained TPH-g up to 1,330-ppm, 47.8-ppm of TPH-d, and 4.3-ppm of benzene. The composite sample identified 144-ppm of TPH-g, 0.7-ppm of benzene, and 7.75-ppm of TPH-d. Groundwater samples identified TPH-g as high as 110,000-ppb, 29,000-ppb of benzene, and 9,700-ppb of TPH-d. Additional exploratory borings were conducted to determine the extent of groundwater contamination. Quarterly groundwater monitoring has continually been conducted and continues to identify levels of contaminants over the applicable screening levels.
Through these assessment activities, several monitoring wells have been installed on and around the Site. Concentrations of TPH-g, TPH-d, and benzene have consistently been detected in groundwater beneath the Site in numerous monitoring events. Benzene was detected in Site monitoring well MW- 15 at 26-micrograms per liter (µg/L) in August 2023 and 1.3-µg/L in February 2024, both above the San Francisco Bay Regional Water Quality Control Board (RWQCB) Tier 1 Environmental Screening Level (ESL) of 0.42-µg/L. Other recent exceedances include TPH-g at 120-µg/L during the August 2023 monitoring event, exceeding the Tier 1 ESL of 100-µg/L.
A Phase I ESA (the Phase 1) was prepared by Cameron-Cole for the Site on September 12th, 2024, on behalf of the County of Solano. The Phase I identified one recognized environmental condition (REC) and one de minimis condition. The concentrations of contaminants in groundwater beneath the Site including, but not limited to, benzene and TPH-g above the RWQCB residential vapor intrusion ESLs likely originating from an off-site source to the north of the Site, constitutes a release of hazardous substances impacting the Site and is therefore considered a REC.
The observed staining in relation to the storage of vehicles and heavy equipment under the awning area south of the storage building is considered to represent a de minimis condition.
1.3 Phase II ESA Scope of Work
To further assess the current conditions of the property identified in the Phase I ESA in accordance with the current applicable regulatory standard, a Phase II Investigation was conducted by Cameron- Cole. The scope of work for this Phase II includes the following sampling activities:
- Assess the extent, if any, of subsurface contamination in relation to detected contaminant concentrations likely originating from an off-site source to the north of the Site by collecting one soil sample analyzed for TPH-g, TPH-d, TPH as motor oil (TPH-mo), CAM 17 metals, and Volatile Organic Compounds (VOCs), and one groundwater sample analyzed for TPH-g, TPH-d, TPH-mo, and VOCs. Additionally, install and sample 11 dual nested soil gas wells for analysis of VOCs by USEPA Method TO-15.
- Assess the extent, if any, of surface contamination in the vehicle parking and equipment storage area under the awning south of the storage building by collecting four near surface soil samples for analysis of TPH-g, TPH-d, TPH-mo, CAM 17 metals, and VOCs.
2.0 SAMPLING METHODS
Prior to conducting any drilling activities, a boring application and permit was submitted to the Solano County Environmental Health Division (SCEHD) (Appendix A). All borings included the installation of soil gas wells with probes at 5 and 15 ft bgs. One boring (DCY-SG-11) continued to a depth of 40 feet to collect soil and groundwater samples. The permit was approved by the SCEHD on February 10th, 2025. In accordance with permit conditions, the SCEHD was notified 48-hours prior to the drilling start date. Prior to drilling, an underground service alert (USA) ticket was submitted and completed a minimum of 72-hours prior to work to minimize the chance of encountering subsurface utilities during drilling. In addition, a professional utility clearance was completed by ForeSite Engineering Surveys Inc. to aid in identifying private utilities which may not be identified by the USA ticket.
2.1.1 Soil Gas Well Installation
Soil gas wells were installed in grid covering the center and outlying edges of the site (Figure 3). Soil gas wells were installed in accordance with methods outlined for the direct push method in the Active Soil Gas Investigations advisory published by the Department of Toxic Substances Control (DTSC, 2015). At each soil boring location shown in Figure 3, a 2 ¼-inch diameter boring was advanced using a combination of a Geoprobe direct push drilling rig and a hand auger. All soil borings were logged according to the Unified Soil Classification System (USCS) and are included in Appendix B. A soil gas probe was connected to Teflon tubing and lowered to 6-inches above the bottom of the boring. Sand was tremied into the boring up to 6-inches above the probe, followed by one foot of dry bentonite.
One foot of hydrated bentonite was then tremied into the boring. Grout was then placed into the boring up to a depth of 5.5-ftbs. An additional 6-inches of sand was placed prior to placing an additional probe at 5-ftbgs, followed by an additional 6-inches of sand, 1 foot of dry bentonite, and 1 foot of hydrated bentonite. Grout was then placed into the boring until just below the ground surface.
A flush mounted well box was then installed at the surface and grouted into place. SCEHD was onsite to inspect the grouting of multiple soil gas well installations. In accordance with DTSC guidance for the installation of soil gas probes using the direct push method, the wells were allowed to equalize for a minimum of two hours prior to conducting leak testing and the collection of samples.
2.1.2 Soil Sampling Procedures
The soil boring for DCY-SG-11 continued to a depth of 40 feet to collect soil and groundwater samples.
A soil sample from DCY-SG-11 was collected at first encountered groundwater (40 ft bgs) and placed into a laboratory provided container which was labeled with the sample name, sample date and time, and submitted to Pace Analytical, a California-certified laboratory, under chain of custody protocol for analysis of TPH-g by EPA method 8015B, TPH-d and TPH-mo by method 8015M, VOCs by method 8260B, and CAM 17 metals by methods 6010B and 7471A. All samples were stored on ice from time of collection until submission to the laboratory. After collecting the soil and groundwater samples, the boring was backfilled with grout to a depth of 15 feet. The boring was then converted into a soil gas well as described in section 2.1.3.
Soil samples were also collected from four additional surface locations (DCY-SS-N, DCY-SS-S, DCY- SS-W, and DCY-SS-E) in the vehicle parking and equipment storage area south of the storage building as shown in Figure 3. The samples were collected by removing plant litter and debris from the ground surface, then using a hand trowel to collect surface soils and transferring the soil into laboratory provided jars. Sample jars were labeled with the sample name, sample date and time, and submitted to Pace Analytical under chain of custody protocol for analysis of TPH-g by EPA method 8015B, TPH-d and TPH-mo by method 8015M, VOCs by method 8260B, and CAM 17 metals by methods 6010B and 7471A. All samples were stored on ice from time of collection until submission to the laboratory.
2.1.3 Groundwater Sampling Procedures
One groundwater grab sample was collected from boring DCY-SG-11 at first encountered groundwater (40 ft bgs). The sample was collected using a bailer and transferred into laboratory provided containers which were labeled with the sample name, sample date and time, and submitted to Pace Analytical under chain of custody protocol for analysis of TPH-g by EPA method 8015B, TPH-d and TPH-mo by method 8015M, and VOCs by method 8260B. All samples were stored on ice from time of collection until submission to the laboratory.
2.1.4 Soil Gas Leak Testing and Sampling Procedure
Soil gas sampling included adhering to the equilibration times, conducting the shut-in test, leak and purge volume requirements specified in the advisory (DTSC, 2015). Use of the helium shroud method provides greater confidence that the soil gas samples collected for laboratory analysis are not compromised through the introduction of ambient air into the sample train. A helium shroud concentration of 20% to 30% was maintained within the shroud during purging and sampling. A detailed description of the helium shroud purge and sample procedure is included as Appendix C. Soil gas sampling was conducted using 1-liter passivated stainless steel cannisters provided by the laboratory. Cannister vacuum, shroud and sample helium concentrations, and helium supply pressure were monitored during sampling and recorded on Sampling Event Data Sheets (SEDS) which are included as Appendix D. Soil gas samples were analyzed by Enthalpy Analytical, a California-certified laboratory, for VOCs by EPA method TO-15 and helium, oxygen, methane and carbon dioxide by ASTM D1946. Soil gas well locations are presented in Figure 3.
2.2 Quality Assurance and Quality Control
QC samples collected in the field include one trip blank (TB-01) for the soil and groundwater samples and two duplicates for the soil gas samples.
A trip blank, which is provided by the lab and prefilled with deionized water, accompanied the samples at all times during sampling. The trip blanks are submitted to the lab and analyzed for VOCs by EPA method 8260B to identify potential contamination introduced during the sample preservation, transportation, storage, and analysis. No compounds were detected in TB-01.
A duplicate sample is an additional sample collected from a sampling point to verify the consistency of the laboratory.
Laboratory QA/QC analyses included surrogate recoveries. laboratory control spike and batch blank analyses. Analytical discrepancies noted by the lab for soil samples are as follows:
- Matrix spike recovery was not within control limits for TPH-g in batch B206779, however the parent sample was not a project sample.
- Matrix spike recovery and precision were not within control limits for TPH-g in batch
B206894, which used project sample DCY-SS-N.
- Surrogate recovery was low due to matrix interference and was not within the control limits for trifluorotoluene in batch B206894, which used project sample DCY-SS-
N.
- Matrix spike recoveries were not within the control limits for TPH-d and TPH-mo in batch B206836, which used project sample DCY-SS-S.
- Surrogate recovery was not within the control limits and the surrogate could not be reported due to sample dilution in the MS/MSD for tetracosane in batch B206836, which used project sample DCY-SS-S.
- Sample precision was not within control limits for the duplicate sample in the MS/MSD for lead in batch B206862, which used project sample DCY-SS-N.
- The difference between duplicate readings was less than the quantitation limit for molybdenum, which also had an estimated value, in batch B206862 using project sample
DCY-SS-N.
- Matrix spike recoveries were not within the control limits and sample precision was not within the control limits for zinc in the MS/MSD in batch B206862, which used project sample DCY-SS-N.
Follow up communication from the laboratory confirmed these QA/QC flags do not denote a significant issue with the analysis results in the samples associated with them.
Soil Gas sample DCY-SG-03-15 noted a discrepancy between the final vacuum recorded in the field compared to the laboratory vacuum. The reported data has been flagged with a "CN" qualifier to indicate estimated values subject to potential bias due to the uncertainty in the pressurization factor.
Soil Gas sample DCY-SG-02-05’s analysis of 4-Ethyltoluene has been flagged with a "CN" qualifier because of a high bias due to matrix contribution.
No other analytical issues were identified by the laboratories. Helium leak detection was utilized during soil gas well purging to aid in ensuring sample train continuity prior to the collection of the samples.
Methods for the helium shroud method are described in section 2.1.3 and in Appendix C. Helium was not identified above laboratory reporting limits in any soil gas sample collected, indicating that no leaks were present during well purging or sample collection. All laboratory reports are presented in Appendix E.
3.0 RESULTS
This section provides the results of the sampling conducted as described in Section 2.0. Certified laboratory reports are provided as Appendix E. Soil, groundwater, and soil gas samples were collected to evaluate the REC and de minimis conditions that were identified in the Phase I.
3.1 Screening Level Selection
The RWQCB has established Environmental Screening Levels (ESLs) for over 100 commonly encountered contaminants. The most recent iteration of the ESLs were published in January 2019 and include screening levels for soil, groundwater, and soil gas. Under most instances, it is unlikely that the presence of a chemical in soil, soil gas, or groundwater below the corresponding ESL will pose a significant threat to human health, water resources, or the environment. To determine the appropriate screening level for a site, the planned future use of the property must be considered. It is our understanding that the future use of the Site post redevelopment will consist of short-term housing for agricultural staff. Considering this site use, the screening levels used are as follows:
Soil
The screening levels used for soil are the RWQCB residential shallow soil exposure and groundwater leaching ESLs (Table 1) due to the residential nature of the planned development. The lower of the two basis values were used and for compounds which have established both cancer and non-cancer hazard levels, the lower value was listed. Detected metal concentrations were compared to the published background metals concentrations as described in the Kearney Foundation Special Report Background Concentrations of Trace and Major Elements in California Soils (Kearney, 1996).
Concentrations within the published range of background values were considered background in nature and will not require further assessment or remediation, regardless of their concentrations relative to the ESL. Upper bound background concentrations for metals of concern are presented in Table 1.
Groundwater
The screening levels used for groundwater are the RWQCB Tier 1 ESLs (Table 1). These screening levels are appropriate for evaluating potential groundwater use at the Site (e.g. drinking or agricultural supply well) and are also protective of any vapor inhalation exposure derived from VOCs off-gassing from groundwater.
Soil Gas
The screening levels used for soil gas are the RWQCB sub slab/soil gas residential ESLs (Table 2).
This screening level is appropriate due to the anticipated residential nature of the proposed redevelopment. For compounds which have established both cancer and non-cancer hazard levels, the lower value will be used.
3.2 Soil Results
Four surface soil samples and one soil sample at 40 ft bgs were collected to evaluate the REC and de minimis condition identified in the Phase I. Table 3 presents soil sampling results for TPH, including TPH-g, TPH-d, and TPH-mo, CAM 17 metals and VOCs.
In the soil sample taken from 40 ft bgs (DCY-SS-11) TPH-d and TPH-mo were detected above the laboratory reporting levels but below their respective screening levels. TPH-d was detected in all four surface samples, however only one sample (DCY-SS-S) had a detected concentration (1,100 milligrams per kilogram [mg/kg]) that was above the screening level of 260 mg/kg. TPH-mo was detected in all four surface soil samples at concentrations below the screening level.
Detectable concentrations of several metals were observed in all soil samples for CAM 17 metals, however, all metals detected above their laboratory reporting limits were below their respective screening levels.
No VOCs were detected above laboratory reporting limits in soil.
3.3 Groundwater Results
Analytical results from the groundwater sample (DCY-GW-11) are presented in Tables 4 for TPH and VOCs. No compounds were detected above laboratory reporting limits for both TPH and VOCs.
3.4 Soil Gas Results
Results from the soil gas samples are provided in Table 5. Compounds which exceeded their screening level are as follows:
DCY-SG-02-05
- Benzene at 26 mg/kg
DCY-SG-11-15
- Benzene at 12 mg/kg
As presented above and in Table 5, benzene was detected in soil gas well DCY-SG-02 at a sample depth of 5 ft bgs but was not detected in the deeper sample collected from 15 ft bgs. Additionally, benzene was detected at soil gas well DCY-SG-11 in the sample at 15 ft bgs but was not detected in the 5 ft bgs sample or in the soil and groundwater samples at 40 ft bgs. These data do not suggest a continuing groundwater source for the detected benzene concentrations and likely represent residual concentrations from the volatilization and lateral migration of benzene from the upgradient property.
Three analytes (1,2-dibromoethane, hexachlorobutadiene, and vinyl chloride) had soil gas method detection limits that were slightly higher than the ESL. However, 1,2-dibromoethane, hexachlorobutadiene, and vinyl chloride are not considered contaminants of concern at the Site and are not likely to be present.
Table 5 presents the analytical results for permanent gases and indicates that helium was not detected in any of the soil gas samples.
4.0 Conclusions and Recommendations
Based upon the sampling presented in Section 2.0 and the results presented in Section 3.0, the following conclusions and recommendations are provided regarding the REC and de minimis conditions identified at the Site in the Phase 1.
4.1 Soil Results
TPH-d was detected above the ESL in one surface soil sample (DCY-SS-S) collected from the southern portion of the vehicle and equipment storage area. Sample DCY-SS-S had a TPH-d concentration of 1,100 mg/kg. The four other soil samples had detections of TPH-d which did not exceed the ESL of 260 mg/kg. Based upon this data, TPH-d impacts do not appear to be widespread and are likely localized and related to small surface spills from parked vehicles. Small de minimus releases as have been observed at the Site are unlikely to be associated with any significant exposure at the Site following redevelopment and no further action is recommended.
4.2 Groundwater Results
Groundwater was collected at a depth of 40 ft bgs from DCY-SG-11 located within the southeastern portion of the Site. No compounds were detected above laboratory reporting limits for both TPH (including TPH-g, TPH-d, and TPH-mo) and VOCs. These data indicate that no further action with regard to groundwater at the Site is appropriate.
4.3 Soil Gas Results
Benzene was detected at concentrations above the ESL in soil gas wells DCY-SG-02 (26 micrograms per meter cubed [µg/m3]) and DCY-SG-11 (12 µg/m3) at depths of 5 and 15 ft bgs, respectively.
Benzene was not detected in the deeper soil gas sample at DCY-SG-02 and was also not detected in the soil and groundwater samples at 40 ft bgs in DCY-SG-11. These data do not suggest a continuing groundwater source for the detected benzene concentrations and likely represent residual concentrations due to the volatilization and lateral migration of benzene from the upgradient property.
The concentration detected in DCY-SG-11 may indicate residual volatilized benzene that is no longer sourced by groundwater but has not fully attenuated. Since benzene was not detected in any of the other soil gas wells, it is likely that impacts are localized at the Site and not widespread. Observed benzene impacts in soil gas at the Site are very limited and do not warrant further corrective action.
5.0 References
Cameron-Cole. 2024. Phase I Environmental Site Assessment, 580 North First Street Dixon, CA.
September 12th, 2024.
Department of Toxic Substances Control, Cal EPA, Los Angeles RWQCB, San Francisco RWQCB, 2015. Advisory Active Soil Gas Investigations, July 2015.
Kearney Foundation of Soil Science Division of Agricultural and Natural Resources, University of California, Kerney Foundation Special Report. Background Concentrations of Trace and Major Elements in California Soils, March 1996.
ssa
B a Slc»i'' � ,-'1' q,O f
A1onrezuma
Slough
Source: Census 2000 Data, The California Spatial Information Library (CaSIL).
CAMERON-COLE
creating 1ust1lnable success
ANAO£CtN�
9/2024 I DixonFigure2Regional.mxd
N
A 0 1.252.5
I II I I I
5 Miles
I t-• -- -· -- -· ---
I
Figure 1: Regional Location Map
COUNTY OF SOLANO• DIXON, CALI FORNI A
PHASE I ESA
CAMERON-COLE N
crt1tln9 tutt1ln1bl1 IUCCtH
ANAOE:c 1N�ATION A 9/2024 I DixonSiteMap.mxd
O 12.525
I II I I I
50 Meters
I I Figure 2: Site Map
SOLANO COUNTY. DIXON CORP YARD
DCY-SG-07
DCY-SG-11
DCY-SG-10
DCY-SG-09
DCY-SG-06
DCY-SG-05
DCY-SG-01
DCY-SG-02 DCY-SG-03 DCY-SG-04
DCY-SG-08
MW-10R
MW-11
MW-15
MW-9 MW-7
MW-18
MW-8
MW-10
RW-4
RW-3
DCY-SS-E
DCY-SS-W
DCY-SS-N
DCY-SS-S
50 HEGENBERGER LOOP
OAKLAND, CALIFORNIA 94621
PHONE: 510-777-1870 FAX: 510-777-1871
http://www.cameron-cole.com
FIGURE 3
SITE MAP WITH COMPOUND
EXCEEDANCES
580 NORTH FIRST STREET, DIXON
SOLANO COUNTY, CALIFORNIA
AS SHOWN
SCALE: DATE: PROJECT NO.
05/15/2025 02085.0057
Google Earth
LEGEND:
SITE BOUNDARY
MONITORING WELL LOCATION
RECOVERY WELL LOCATION
SOIL GAS BORING LOCATION
DESTROYED MONITORING WELL
MW-8
RW-2
DCY-SG-01
MW-10
Well No. Benzene
DCY-SG-02-05 26 ug/m3
Well No. Benzene
DCY-SG-11-15 12 ug/m3
Well No.
TPRH - Diesel Range Organics (C13 - C22)
DCY-SS-S 1,100 mg/kg
AutoCAD SHX Text
FIRST STREET (HWY 113)
AutoCAD SHX Text
FIRST STREET (HWY 113)
AutoCAD SHX Text
STORAGE SOLANO COUNTY PUBLIC WORKS
AutoCAD SHX Text
STORAGE SOLANO COUNTY PUBLIC WORKS
AutoCAD SHX Text
OFFICE BUILDING
AutoCAD SHX Text
OFFICE BUILDING
AutoCAD SHX Text
ABOVE GROUND STORAGE TANKS
AutoCAD SHX Text
ABOVE GROUND STORAGE TANKS
AutoCAD SHX Text
ADVANCED AUTO GLASS
AutoCAD SHX Text
ADVANCED AUTO GLASS
AutoCAD SHX Text
EAST F STREET
AutoCAD SHX Text
EAST F STREET
AutoCAD SHX Text
SERVICE BAY
AutoCAD SHX Text
SERVICE BAY
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
GREASE RACK
AutoCAD SHX Text
GREASE RACK
AutoCAD SHX Text
FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text N
Table 1
Environmental Screening Levels: Soil and Groundwater
Dixon Corp Yard - 580 North First Street, Dixon
CAS Number Analyte
Soil Environmental
Screening Level (ESL)
(mg/kg) ¹ Basis for Soil ESL¹
Background Soil
Concentration
(mg/kg) ²
Tier 1
Groundwater ESL
(µg/L) ¹
Basis for
Groundwater ESL¹
Standard List VOCs
630-20-6 1,1,1,2-Tetrachloroethane 1.7E-02 Leaching - 5.7E-01 Tap Canc-Risk
71-55-6 1,1,1-Trichloroethane 7.0E+00 Leaching - 6.2E+01 Aquatic Habitat
79-34-5 1,1,2,2-Tetrachloroethane 1.8E-02 Leaching - 1.0E+00 MCL
76-13-1 1,1,2-Trichloro-1,2,2-trifluoroethane - - - - -
79-00-5 1,1,2-Trichloroethane 7.6E-02 Leaching - 5.0E+00 MCL
75-34-3 1,1-Dichloroethane 2.0E-01 Leaching - 5.0E+00 MCL
75-35-4 1,1-Dichloroethene 5.4E-01 Leaching - 3.2E+00 Aquatic Habitat
563-58-6 1,1-Dichloropropene - - - - -
87-61-6 1,2,3-Trichlorobenzene - - - - -
96-18-4 1,2,3-Trichloropropane 1.1E-04 Leaching - 5.0E-03 MCL
120-82-1 1,2,4-Trichlorobenzene 1.2E+00 Leaching - 5.0E+00 MCL
95-63-6 1,2,4-Trimethylbenzene - - - - -
96-12-8 1,2-Dibromo-3-Chloropropane 5.9E-04 Leaching - 2.8E-02 Vapor Intrusion
95-50-1 1,2-Dichlorobenzene 1.0E+00 Leaching - 1.4E+01 Aquatic Habitat
107-06-2 1,2-Dichloroethane 7.0E-03 Leaching - 5.0E-01 MCL
78-87-5 1,2-Dichloropropane 6.5E-02 Leaching - 2.3E+00 Vapor Intrusion
108-67-8 1,3,5-Trimethylbenzene - - - - -
541-73-1 1,3-Dichlorobenzene 7.4E+00 Leaching - 6.5E+01 Aquatic Habitat
142-28-9 1,3-Dichloropropane - - - - -
106-46-7 1,4-Dichlorobenzene 2.0E-01 Leaching - 2.6E+00 Vapor Intrusion
594-20-7 2,2-Dichloropropane - - - - -
78-93-3 2-Butanone (MEK) 6.1E+00 Leaching - 5.6E+03 Tap NC-Hazard
95-49-8 2-Chlorotoluene - - - - -
591-78-6 2-Hexanone - - - - -
106-43-4 4-Chlorotoluene - - - - -
99-87-6 4-Isopropyltoluene - - - - -
108-10-1 4-Methyl-2-pentanone (MIBK) 3.6E-01 Leaching - 1.2E+02 Tap NC-Hazard
67-64-1 Acetone 9.2E-01 Leaching - 1.5E+03 Aquatic Habitat
71-43-2 Benzene 2.5E-02 Leaching - 4.2E-01 Vapor Intrusion
108-86-1 Bromobenzene - - - - -
75-25-2 Bromoform 6.9E-01 Leaching - 8.0E+01 MCL
74-83-9 Bromomethane 3.6E-01 Leaching - 7.5E+00 Tap NC-Hazard
75-15-0 Carbon disulfide - - - - -
56-23-5 Carbon tetrachloride 7.6E-02 Leaching - 4.3E-01 Vapor Intrusion
108-90-7 Chlorobenzene 1.4E+00 Leaching - 2.5E+01 Aquatic Habitat
74-97-5 Chlorobromomethane - - - - -
124-48-1 Chlorodibromomethane 3.5E-01 Leaching - 3.4E+01 Aquatic Habitat
75-00-3 Chloroethane 1.2E+00 Leaching - 1.6E+01 Odor/Nuis
67-66-3 Chloroform 2.3E-02 Leaching - 8.1E-01 Vapor Intrusion
74-87-3 Chloromethane 1.1E+01 Leaching - 1.9E+02 Tap NC-Hazard
156-59-2 cis-1,2-Dichloroethene 1.9E-01 Leaching - 6.0E+00 MCL
10061-01-5 cis-1,3-Dichloropropene - - - - -
74-95-3 Dibromomethane - - - - -
75-27-4 Dichlorobromomethane 1.6E-02 Leaching - 8.7E-01 Vapor Intrusion
75-71-8 Dichlorodifluoromethane - - - - -
100-41-4 Ethylbenzene 4.3E-01 Leaching - 3.5E+00 Vapor Intrusion
106-93-4 Ethylene Dibromide 5.3E-04 Leaching - 5.0E-02 MCL
87-68-3 Hexachlorobutadiene 2.8E-02 Leaching - 1.4E-01 Tap Canc-Risk
98-82-8 Isopropylbenzene - - - - -
1634-04-4 Methyl tert-butyl ether 2.8E-02 Leaching - 5.0E+00 Odor/Nuis
75-09-2 Methylene Chloride 1.2E-01 Leaching - 5.0E+00 MCL
91-20-3 Naphthalene 4.2E-02 Leaching - 1.7E-01 Tap Canc-Risk
104-51-8 n-Butylbenzene - - - - -
103-65-1 N-Propylbenzene - - - - -
135-98-8 sec-Butylbenzene - - - - -
100-42-5 Styrene 9.2E-01 Leaching - 1.0E+01 Odor/Nuis
98-06-6 tert-Butylbenzene - - - - -
127-18-4 Tetrachloroethene 8.0E-02 Leaching - 6.4E-01 Vapor Intrusion
108-88-3 Toluene 3.2E+00 Leaching - 4.0E+01 Odor/Nuis
Table 1
Environmental Screening Levels: Soil and Groundwater
Dixon Corp Yard - 580 North First Street, Dixon
CAS Number Analyte
Soil Environmental
Screening Level (ESL)
(mg/kg) ¹ Basis for Soil ESL¹
Background Soil
Concentration
(mg/kg) ²
Tier 1
Groundwater ESL
(µg/L) ¹
Basis for
Groundwater ESL¹
Standard List VOCs continued
156-60-5 trans-1,2-Dichloroethene 6.5E-01 Leaching - 1.0E+01 MCL
10061-02-6 trans-1,3-Dichloropropene - - - - -
79-01-6 Trichloroethene 8.5E-02 Leaching - 1.2E+00 Vapor Intrusion
75-69-4 Trichlorofluoromethane - - - - -
108-05-4 Vinyl acetate - - - - -
75-01-4 Vinyl chloride 1.5E-03 Leaching - 8.6E-03 Vapor Intrusion
1330-20-7 Xylenes, Total 2.1E+00 Leaching - 2.0E+01 Odor/Nuis
Metals
7440-36-0 Antimony 1.1E+01 NC-Hazard 1.95 - -
7440-38-2 Arsenic 6.7E-02 Canc-Risk 11 - -
7440-39-3 Barium 1.5E+04 NC-Hazard 1400 - -
7440-41-7 Beryllium 1.6E+01 NC-Hazard 2.7 - -
7440-43-9 Cadmium 7.8E+01 NC-Hazard 1.7 - -
7440-47-3 Chromium - - 1579 - -
7440-48-4 Cobalt 2.3E+01 NC-Hazard 46.9 - -
7440-50-8 Copper 3.1E+03 NC-Hazard 96.4 - -
7439-92-1 Lead 8.0E+01 NC-Hazard 97.1 - -
7439-98-7 Molybdenum 3.9E+02 NC-Hazard 9.6 - -
7440-02-0 Nickel 8.2E+02 NC-Hazard 509 - -
7782-49-2 Selenium 3.9E+02 NC-Hazard 0.43 - -
7440-22-4 Silver 3.9E+02 NC-Hazard 8.3 - -
7440-28-0 Thallium 7.8E-01 NC-Hazard 1.1 - -
7440-62-2 Vanadium 3.9E+02 NC-Hazard 288 - -
7440-66-6 Zinc 2.3E+04 NC-Hazard 236 - -
7439-97-6 Mercury 1.3E+01 NC-Hazard 0.9 - -
Total Petroleum Hydrocarbons
- TPH- Gasoline 4.3E+02 NC-Hazard - 1.0E+02 Odor/Nuis
- TPH- Diesel 2.6E+02 NC-Hazard - 1.0E+02 Odor/Nuis
- TPH- Motor Oil 1.2E+04 NC-Hazard - - -
Notes: ¹ values are from the 2019 Regional Water Quality Control Board's " Environmental Screening Level Workbook"
²values are maximums from the 1996 Kearney Foundation's "Background Concentrations of Trace and Major Elements in California Soils"
Table 2
Environmental Screening Levels: Soil Gas
Dixon Corp Yard - 580 North First Street, Dixon
CAS Number Analyte
Soil Vapor Environmental
Screening Level (ESL)
(µg/m3) ¹ Basis for ESL ¹
VOCs
630-20-6 1,1,1,2-Tetrachloroethane 1.3E+01 Canc-Risk
71-55-6 1,1,1-Trichloroethane 3.5E+04 NC-Hazard
79-34-5 1,1,2,2-Tetrachloroethane 1.6E+00 Canc-Risk
79-00-5 1,1,2-Trichloroethane 5.8E+00 Canc-Risk
75-34-3 1,1-Dichloroethane 5.8E+01 Canc-Risk
75-35-4 1,1-Dichloroethene 2.4E+03 NC-Hazard
75-37-6 1,1-Difluoroethane - -
120-82-1 1,2,4-Trichlorobenzene 7.0E+01 NC-Hazard
95-63-6 1,2,4-Trimethylbenzene - -
106-93-4 1,2-Dibromoethane 1.6E-01 Canc-Risk
95-50-1 1,2-Dichlorobenzene 7.0E+03 NC-Hazard
107-06-2 1,2-Dichloroethane 3.6E+00 Canc-Risk
78-87-5 1,2-Dichloropropane 9.4E+00 Canc-Risk
108-67-8 1,3,5-Trimethylbenzene - -
541-73-1 1,3-Dichlorobenzene - --
106-46-7 1,4-Dichlorobenzene 8.5E+00 Canc-Risk
123-91-1 1,4-Dioxane 1.2E+01 Canc-Risk
78-93-3 2-Butanone 1.7E+05 NC-Hazard
591-78-6 2-Hexanone - -
622-96-8 4-Ethyltoluene - -
108-10-1 4-Methyl-2-Pentanone 1.0E+05 NC-Hazard
67-64-1 Acetone 1.1E+06 NC-Hazard
71-43-2 Benzene 3.2E+00 Canc-Risk
100-44-7 Benzyl chloride - -
75-27-4 Bromodichloromethane 2.5E+00 Canc-Risk
460-00-4 Bromofluorobenzene - -
75-25-2 Bromoform 8.5E+01 Canc-Risk
74-83-9 Bromomethane 1.7E+02 NC-Hazard
75-15-0 Carbon Disulfide - -
56-23-5 Carbon Tetrachloride 1.6E+01 Canc-Risk
108-90-7 Chlorobenzene 1.7E+03 NC-Hazard
75-00-3 Chloroethane 3.5E+05 NC-Hazard
67-66-3 Chloroform 4.1E+00 Canc-Risk
74-87-3 Chloromethane 3.1E+03 NC-Hazard
156-59-2 cis-1,2-Dichloroethene 2.8E+02 NC-Hazard
10061-01-5 cis-1,3-Dichloropropene - -
124-48-1 Dibromochloromethane - --
100-41-4 Ethylbenzene 3.7E+01 Canc-Risk
76-13-1 Freon 113 - -
76-14-2 Freon 114 - -
75-71-8 Freon 12 - -
7440-59-7 Helium - -
Table 2
Environmental Screening Levels: Soil Gas
Dixon Corp Yard - 580 North First Street, Dixon
CAS Number Analyte
Soil Vapor Environmental
Screening Level (ESL)
(µg/m3) ¹ Basis for ESL ¹
VOCs continued
87-68-3 Hexachlorobutadiene 4.3E+00 Canc-Risk
67-63-0 Isopropanol (IPA) - -
179601-23-1 m,p-Xylenes - -
75-09-2 Methylene Chloride 3.4E+01 Canc-Risk
1634-04-4 MTBE 3.6E+02 Canc-Risk
91-20-3 Naphthalene 2.8E+00 Canc-Risk
110-54-3 n-Hexane - -
95-47-6 o-Xylene - -
100-42-5 Styrene 3.1E+04 NC-Hazard
127-18-4 Tetrachloroethene 1.5E+01 Canc-Risk
108-88-3 Toluene 1.0E+04 NC-Hazard
- TPH ref. to Gasoline 2.0E+04 -
156-60-5 trans-1,2-Dichloroethene 2.8E+03 NC-Hazard
10061-02-6 trans-1,3-Dichloropropene - -
79-01-6 Trichloroethene 1.6E+01 Canc-Risk
75-69-4 Trichlorofluoromethane - -
108-05-4 Vinyl Acetate - -
75-01-4 Vinyl Chloride 3.2E-01 Canc-Risk
1330-20-7 Xylene (total) 3.5E+03 NC-Hazard
Notes: ¹ values are from the 2019 Regional Water Quality Control Board's " Environmental Screening Level Workbook"
Table 3 Soil Sampling Results (mg/kg)
Dixon Corp Yard - 580 North First Street, Dixon
Constituent EPA Method Screening Level
D C
Y -S
S -N
D C
Y -S
S -S
D C
Y -S
S -E
D C
Y -S
S -W
D C
Y -S
S -11
02/21/25 02/21/25 02/21/25 02/21/25 02/21/25
Surface Surface Surface Surface 40
TPH - Gasoline Range Organics (C4 - C12) 8015B 4.3E+02 <1.0 <1.0 <1.0 <1.0 <1.0 TPH - Diesel Range Organics (C13 - C22) 8015B 2.6E+02 30 1100 23 33 1.5
TPH - Oil Range Organics (C23 - C40) 8015B 1.2E+04 240 2300 210 300 6.5
Antimony 6010B 1.1E+01 <5.0 <5.0 <5.0 <5.0 <5.0 Arsenic 6010B 1.1E+01 5.4 5.5 4.8 5.3 5.7 Barium 6010B 1.5E+04 120 130 120 120 120
Beryllium 6010B 1.6E+01 0.21J 0.19J 0.26J 0.25J 0.32J Cadmium 6010B 7.8E+01 0.48J 0.86 0.63 0.69 0.27J Chromium 6010B 1.6E+03 75 94 59 93 80
Cobalt 6010B 4.7E+01 15 14 16 17 13 Copper 6010B 3.1E+03 26 31 34 37 29 Lead 6010B 9.7E+01 35 63 45 29 3.5
Molybdenum 6010B 3.9E+02 0.52J 0.73J 0.31J 0.50J 0.25J Nickel 6010B 8.2E+02 110 140 110 130 160
Selenium 6010B 3.9E+02 <1.0 <1.0 <1.0 <1.0 <1.0 Silver 6010B 3.9E+02 <0.50 <0.50 <0.50 <0.50 <0.50
Thallium 6010B 7.8E-01 <5.0 <5.0 <5.0 <5.0 <5.0 Vanadium 6010B 3.9E+02 51 48 64 73 51
Zinc 6010B 2.3E+04 220 460/440 270 280 58 Mercury 7471A 1.3E+01 0.13J 0.45 0.40 0.21 0.10J
1,1,1,2-Tetrachloroethane 8260B 1.7E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,1,1-Trichloroethane 8260B 7.0E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,1,2,2-Tetrachloroethane 8260B 1.8E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,1,2-Trichloro-1,2,2-trifluoroethane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,1,2-Trichloroethane 8260B 7.6E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,1-Dichloroethane 8260B 2.0E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,1-Dichloroethene 8260B 5.4E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,1-Dichloropropene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2,3-Trichlorobenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2,3-Trichloropropane 8260B 1.1E-04 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2,4-Trichlorobenzene 8260B 1.2E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2,4-Trimethylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,2-Dibromo-3-chloropropane 8260B 5.9E-04 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2-Dibromoethane 8260B 5.3E-04 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,2-Dichlorobenzene 8260B 1.0E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,2-Dichloroethane 8260B 7.0E-03 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,2-Dichloropropane 8260B 6.5E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,3,5-Trimethylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
1,3-Dichloropropane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 1,4-Dichlorobenzene 8260B 2.0E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 2,2-Dichloropropane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
2-Chlorotoluene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 4-Chlorotoluene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Benzene 8260B 2.5E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Total Petroleum Hydrocarbons
Metals
VOCs
Sample Date
Depth (Feet)
Table 3 Soil Sampling Results (mg/kg)
Dixon Corp Yard - 580 North First Street, Dixon
Constituent EPA Method Screening Level
D C
Y -S
S -N
D C
Y -S
S -S
D C
Y -S
S -E
D C
Y -S
S -W
D C
Y -S
S -11
02/21/25 02/21/25 02/21/25 02/21/25 02/21/25
Surface Surface Surface Surface 40
Sample Date
Depth (Feet)
Bromobenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Bromochloromethane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Bromodichloromethane 8260B 1.6E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Bromoform 8260B 6.9E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Bromomethane 8260B 3.6E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Carbon tetrachloride 8260B 7.6E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Chlorobenzene 8260B 1.4E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Chloroethane 8260B 1.2E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Chloroform 8260B 2.3E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Chloromethane 8260B 1.1E+01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 cis-1,2-Dichloroethene 8260B 1.9E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 cis-1,3-Dichloropropene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Dibromochloromethane 8260B 3.5E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Dibromomethane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Dichlorodifluoromethane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Ethylbenzene 8260B 4.3E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Hexachlorobutadiene 8260B 2.8E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Isopropylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Methyl t-butyl ether 8260B 2.8E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Methylene chloride 8260B 1.2E-01 <0.010 <0.010 <0.010 <0.010 <0.010
Naphthalene 8260B 4.2E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 n-Butylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 n-Propylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 o-Xylene 8260B NA <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 p- & m-Xylenes 8260B NA <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 p-Isopropyltoluene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 sec-Butylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Styrene 8260B 9.2E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 tert-Butylbenzene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Tetrachloroethene 8260B 8.0E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Toluene 8260B 3.2E+00 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Total Xylenes 8260B 2.1E+00 <0.010 <0.010 <0.010 <0.010 <0.010 trans-1,2-Dichloroethene 8260B 6.5E-01 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 trans-1,3-Dichloropropene 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Trichloroethene 8260B 8.5E-02 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050 Trichlorofluoromethane 8260B - <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Vinyl chloride 8260B 1.5E-03 <0.0050 <0.0050 <0.0050 <0.0050 <0.0050
Note:
Bolded value indicates result above screening level
VOCs Continued
Table 4 Groundwater Sampling Results (ug/L)
Dixon Corp Yard - 580 North First Street, Dixon
Constituent EPA Method Environmental Screening Level
D C
Y -G
W -11
02/21/25
TPH - Gasoline Range Organics (C4 - C12) 8015B 1.0E+02 <50 TPH - Diesel Range Organics (C13 - C22) 8015B 1.0E+02 <50
TPH - Oil Range Organics (C23 - C40) 8105B - <100
1,1,1,2-Tetrachloroethane 8260B 5.7E-01 <0.50 1,1,1-Trichloroethane 8260B 6.2E+01 <0.50
1,1,2,2-Tetrachloroethane 8260B 1.0E+00 <0.50 1,1,2-Trichloro-1,2,2-trifluoroethane 8260B - <0.50
1,1,2-Trichloroethane 8260B 5.0E+00 <0.50 1,1-Dichloroethane 8260B 5.0E+00 <0.50 1,1-Dichloroethene 8260B 3.2E+00 <0.50
1,1-Dichloropropene 8260B - <0.50 1,2,3-Trichlorobenzene 8260B - <0.50 1,2,3-Trichloropropane 8260B 5.0E-03 <1.0 1,2,4-Trichlorobenzene 8260B 5.0E+00 <0.50 1,2,4-Trimethylbenzene 8260B - <0.50
1,2-Dibromo-3-chloropropane 8260B 2.8E-02 <1.0 1,2-Dibromoethane 8260B 5.0E-02 <0.50
1,2-Dichlorobenzene 8260B 1.4E+01 <0.50 1,2-Dichloroethane 8260B 5.0E-01 <0.50
1,2-Dichloropropane 8260B 2.3E+00 <0.50 1,3,5-Trimethylbenzene 8260B - <0.50
1,3-Dichloropropane 8260B - <0.50 1,4-Dichlorobenzene 8260B 2.6E+00 <0.50 2,2-Dichloropropane 8260B - <0.50
2-Chlorotoluene 8260B - <0.50 4-Chlorotoluene 8260B - <0.50
Benzene 8260B 4.2E-01 <0.50 Bromobenzene 8260B - <0.50
Bromochloromethane 8260B - <0.50 Bromodichloromethane 8260B 8.7E-01 <0.50
Bromoform 8260B 8.0E+01 <0.50 Bromomethane 8260B 7.5E+00 <1.0
Carbon tetrachloride 8260B 4.3E-01 <0.50 Chlorobenzene 8260B 2.5E+01 <0.50 Chloroethane 8260B 1.6E+01 <0.50
Sample Date Depth (Feet)
Total Petroleum Hydrocarbons
VOCs
Table 4 Groundwater Sampling Results (ug/L)
Dixon Corp Yard - 580 North First Street, Dixon
Constituent EPA Method Environmental Screening Level
D C
Y -G
W -11
02/21/25
Sample Date Depth (Feet)
Chloroform 8260B 8.1E-01 <0.50 Chloromethane 8260B 1.9E+02 <0.50 cis-1,2-Dichloroethene 8260B 6.0E+00 <0.50 cis-1,3-Dichloropropene 8260B - <0.50 Dibromochloromethane 8260B 3.4E+01 <0.50
Dibromomethane 8260B - <0.50 Dichlorodifluoromethane 8260B - <0.50
Ethylbenzene 8260B 3.5E+00 <0.50 Hexachlorobutadiene 8260B 1.4E-01 <0.50
Isopropylbenzene 8260B - <0.50 Methyl t-butyl ether 8260B 5.0E+00 <0.50 Methylene chloride 8260B 5.0E+00 <1.0
Naphthalene 8260B 1.7E-01 <0.50 n-Butylbenzene 8260B - <0.50 n-Propylbenzene 8260B - <0.50 o-Xylene 8260B NA <0.50 p- & m-Xylenes 8260B NA <0.50 p-Isopropyltoluene 8260B - <0.50 sec-Butylbenzene 8260B - <0.50
Styrene 8260B 1.0E+01 <0.50 tert-Butylbenzene 8260B - <0.50 Tetrachloroethene 8260B 6.4E-01 <0.50
Toluene 8260B 4.0E+01 <0.50 Total Xylenes 8260B 2.0E+01 <1.0 trans-1,2-Dichloroethene 8260B 1.0E+01 <0.50 trans-1,3-Dichloropropene 8260B - <0.50
Trichloroethene 8260B 1.2E+00 <0.50 Trichlorofluoromethane 8260B - <0.50
Vinyl chloride 8260B 8.6E-03 <0.50
Note:
Bolded value indicates result above screening level
VOCs Continued
Table 5
Soil Gas Sampling Results
Dixon Corp Yard - 580 North First Street, Dixon
Constituent
Soil Gas
Environmental
Screening Level Units
D C
Y -S
G -0
-0
D C
Y -S
G -0
-1
D C
Y -S
G -0
-0
D C
Y -S
G -0
-1
D C
Y -S
G -0
-0
D C
Y -S
G -0
-1
D C
Y -S
G -2
-0
D C
Y -S
G -0
-0
D C
Y -S
G -0
-1
D C
Y -S
G -0
-0
3/10/2025 3/10/2025 3/11/2025 3/11/2025 3/11/2025 3/11/2025 3/11/2025 3/11/2025 3/11/2025 3/10/2025
5 15 5 15 5 15 5 5 15 5
1,1,1-Trichloroethane 35000 ug/m 3 <1.1 <1.1 <1.0 <1.1 <1.1 <1.1 <1.1 <1.2 <0.98 <1.2
1,1,2,2-Tetrachloroethane 1.6 ug/m 3 <1.5 <1.4 <1.4 <1.4 <1.4 <1.4 <1.4 <1.6 <1.3 <1.5
1,1,2-Trichloroethane 5.8 ug/m 3 <1.0 <0.99 <0.94 <0.98 <0.95 <0.98 <0.95 <1.1 <0.86 <1.0
1,1-Dichloroethane 58.5 ug/m 3 <0.80 <0.79 <0.74 <0.78 <0.76 <0.78 <0.75 <0.86 <0.69 <0.83
1,1-Dichloroethene 2400.0 ug/m 3 <1.0 <1.0 <0.95 <0.99 <0.96 <0.98 <0.96 <1.1 <0.87 <1.0
1,2,4-Trichlorobenzene 69.5 ug/m 3 <8.0 <7.9 <7.4 <7.8 <7.5 <7.7 <7.5 <8.6 <6.8 <8.2
1,2,4-Trimethylbenzene - ug/m 3 <2.6 <2.5 6.3 <2.5 <2.4 <2.5 <2.4 <2.8 <2.2 <2.6
1,2-Dibromoethane (EDB) 0.2 ug/m 3 <1.5 <1.5 <1.4 <1.4 <1.4 <1.4 <1.4 <1.6 <1.3 <1.5
1,2-Dichlorobenzene 7000.0 ug/m 3 <2.1 <2.0 <1.9 <2.0 <2.0 <2.0 <2.0 <2.2 <1.8 <2.2
1,2-Dichloroethane 3.6 ug/m 3 <0.80 <0.79 <0.75 <0.78 <0.76 <0.78 <0.76 <0.87 <0.69 <0.83
1,2-Dichloropropane 9.4 ug/m 3 <1.1 <1.1 <1.0 <1.1 <1.1 <1.1 <1.1 <1.2 <0.98 <1.2
1,3,5-Trimethylbenzene - ug/m 3 <2.2 <2.1 2.5J <2.1 <2.0 <2.1 <2.0 <2.3 <1.9 <2.2
1,3-Butadiene NA ug/m 3 <1.2 <1.2 <1.1 <1.1 <1.1 <1.1 <1.1 <1.3 <1.0 <1.2
1,3-Dichlorobenzene - ug/m 3 <2.2 <2.2 <2.1 <2.2 <2.1 <2.2 <2.1 <2.4 <1.9 <2.3
1,4-Dichlorobenzene 8.5 ug/m 3 <2.2 <2.1 <2.0 <2.1 <2.0 <2.1 <2.0 <2.3 <1.9 <2.2
1,4-Dioxane 12.2 ug/m 3 <2.2 <2.2 <2.0 <2.1 <2.0 <2.1 <2.0 <2.4 <1.9 <2.2
2,2,4-Trimethylpentane NA ug/m 3 <1.7 <1.7 2.4J <1.6 <1.6 <1.6 <1.6 <1.8 <1.5 <1.8
2-Butanone (Methyl Ethyl Ketone) 170000.0 ug/m 3 4.9J <2.2 5.9J <2.2 <2.1 <2.2 <2.1 4.6J <1.9 <2.3
2-Hexanone - ug/m 3 <3.4 <3.3 <3.1 <3.3 <3.2 <3.2 <3.2 <3.6 <2.9 <3.5
2-Propanol - ug/m 3 3.6J <1.4 <1.3 <1.4 <1.3 <1.4 <1.3 <1.5 2.3J <1.4
3-Chloropropene NA ug/m 3 <1.6 <1.5 <1.4 <1.5 <1.5 <1.5 <1.5 <1.7 <1.3 <1.6
4-Ethyltoluene - ug/m 3 <2.8 <2.7 13 <2.7 <2.6 <2.7 <2.6 <3.0 <2.4 <2.8
4-Methyl-2-pentanone 100000.0 ug/m 3 <1.6 <1.6 <1.5 <1.6 <1.5 <1.6 <1.5 <1.8 <1.4 <1.7
Acetone 1100000.0 ug/m 3 38 <11 32 24 18J 20 16J 68 17J 16J alpha-Chlorotoluene - ug/m 3 <1.8 <1.7 <1.6 <1.7 <1.7 <1.7 <1.6 <1.9 <1.5 <1.8
Benzene 3.2 ug/m 3 <0.58 <0.57 26 2.2J <0.55 0.80 <0.54 1.0J <0.50 1.6J
Bromodichloromethane 2.5 ug/m 3 <1.4 <1.4 <1.3 <1.4 <1.3 <1.3 <1.3 <1.5 <1.2 <1.4
Bromoform 85.1 ug/m 3 <3.6 <3.6 <3.4 <3.5 <3.4 <3.5 <3.4 <3.9 <3.1 <3.8
Bromomethane 170.0 ug/m 3 <3.2 <3.2 <3.0 <3.2 <3.1 <3.1 <3.0 <3.5 <2.8 <3.4
Carbon Disulfide - ug/m 3 14 6.8J 62 18 8.4J 49 8.4J 28 29 33
Carbon Tetrachloride 15.6 ug/m 3 <1.1 <1.1 <1.0 <1.1 <1.1 <1.1 <1.1 <1.2 <0.98 <1.2
Chlorobenzene 1700.0 ug/m 3 <0.67 <0.66 <0.62 <0.65 <0.63 <0.65 <0.63 <0.72 <0.58 <0.70
Chloroethane 350000.0 ug/m 3 <2.4 <2.3 <2.2 <2.3 <2.2 <2.3 <2.2 <2.6 <2.0 <2.4
Chloroform 4.1 ug/m 3 1.3J <1.0 2.6J <0.99 <0.96 <0.98 <0.96 1.8J 2.1J 1.5J
Chloromethane 3100.0 ug/m 3 <9.8 <9.6 <9.1 <9.5 <9.2 <9.5 <9.2 <10 <8.4 <10 cis-1,2-Dichloroethene 280.0 ug/m 3 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.4 <1.1 <1.3 cis-1,3-Dichloropropene - ug/m 3 <1.0 <1.0 <0.97 <1.0 <0.98 <1.0 <0.98 <1.1 <0.89 <1.1
Cumene NA ug/m 3 <2.3 <2.2 <2.1 <2.2 <2.1 <2.2 <2.1 <2.4 <2.0 <2.4
Cyclohexane NA ug/m 3 <0.87 <0.86 2.9J <0.84 <0.82 <0.84 <0.82 <0.94 <0.74 <0.90
Dibromochloromethane - ug/m 3 <1.6 <1.6 <1.5 <1.6 <1.5 <1.6 <1.5 <1.7 <1.4 <1.7
Ethanol NA ug/m 3 <4.0 <4.0 <3.8 <3.9 <3.8 <3.9 <3.8 <4.4 <3.5 <4.2
Ethyl Benzene 37.4 ug/m 3 <1.7 <1.7 21 <1.7 <1.6 <1.7 <1.6 <1.8 <1.5 <1.8
Freon 11 - ug/m 3 <0.65 0.66J 0.92J 0.80J 0.78J 1.1 0.78J 0.98J 1.2J <0.68
Freon 113 - ug/m 3 <2.5 <2.4 <2.3 <2.4 <2.3 <2.4 <2.3 <2.6 <2.1 <2.5
Freon 114 - ug/m 3 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.2 <1.4 <1.1 <1.3
Freon 12 - ug/m 3 1.6J 1.7J 1.8J 1.5J…