DHR Southwest Region 1 HVAC Equipment_7.17.25.pdf
PDF 669 KB Posted
- Attached to
- DHR Choctaw Co HVAC PM FY26
- Solicitation number
- SRC0000033817
- Issued by
- Clarke County, Alabama
About this file
This document is an equipment inventory and inspection schedule for HVAC systems maintained by the Department of Human Resources (DHR) Southwest Region 1 across three Alabama facilities in Choctaw, Clarke, and Washington counties. The file details the specific HVAC equipment currently installed at each location, including split-system heat pumps with auxiliary heaters, condensers, air handler units, and exhaust fans from manufacturers such as American Standard, Carrier, and Trane. The Choctaw County facility (Butler, Alabama) operates eight split-system American Standard heat pumps comprising one 10-ton unit and seven 4-ton units, along with five exhaust fans. The Clarke County facility (Grove Hill, Alabama) maintains four split-system Carrier Gemini air handler units with auxiliary heaters, four outside Carrier condenser/heat pump units, one Carrier direct expansion fan coil unit with electric heater, and two exhaust fans. The Washington County facility (Chatom, Alabama) operates six split-system Trane heat pumps with electric duct heat, one roof-mounted exhaust fan, and two ceiling-mounted exhaust fans.
All three facilities are required to complete and submit signed inspection forms (Forms A and D) during quarterly inspections. The document provides detailed serial numbers and model specifications for each piece of equipment, enabling proper tracking and maintenance verification. No pricing information, bid due dates, response deadlines, or contract terms are included in this inventory document. This appears to be reference material establishing baseline equipment documentation for maintenance and inspection compliance purposes across the DHR Southwest Region 1 service area.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DHR HVAC PM Site Visit Schedule.docx | DOCX document | |
| DOPQQBPV4.08.26.pdf | ||
| HVAC PM DHR Site Location by Region_1.13.26.pdf | ||
| DHR HVAC PM specifications 1-23-26 with revisions_ kg FINAL 4.20.26.docx | DOCX document | |
| County Map DHR location_Site Visit Order_area.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DHR SOUTHWEST REGION 1 HVAC EQUIPMENT
1. DHR Choctaw Co.
1003 S. MULBERRY AVENUE
BUTLER, ALABAMA 36904
Ph: 205-459-9715 Ph: 205-459-9706
Description of System:
(8) SPLIT-SYSTEM AMERICAN STANDARD HEAT PUMPS WITH AUXILIARY HEATERS- Form A Air Handler units 1 10-ton Model TWE120A300DA S/N 2282P89511 7 4-ton Model TWE048C140C0 S/N 22330852V,22331HJ2V,2233KRM2V,2233KT02V, 2233KU12V, KU72V &KU92V
Condensers
1 Model TWA120A300EB S/N 2343YALAD 7 Model 6C0048A300A4 S/N 220171H4F,212551X4F,227221984F,2272219Y4F, 22722AP4F,22722B04F,22722FF4F
(5) EXHAUST FANS- Form D Choctaw Inspection Forms required to be completed & signed during all quarterly inspections:
A, D
2. DHR Clarke Co.
22609 HWY 84 EAST
GROVE HILL, ALABAMA 36451
Ph: 251-275-7024 Ph: 251-275-7030
Description of System:
(4) Split- System Carrier Gemini AHUs w/ Auxiliary Heaters Form A 2 ea. Model 40RUQA12A2A6A0A0A0 S/N 1016U21783, 1512U13841 1 ea. Model 40RUQA08A2A6A0A0A0 S/N 1812U17786 1 ea. Model 40RFQA12A2A5AUA0A0 S/N 4324U28690
(4) Outside Carrier Condenser/Heat Pump units 1 ea. Model 38AUQD12A0A5A0A0A0 S/N 1824C10892 1 ea. Model 38AUQA08A0A5A0A0A0 S/N 0211620076 1 ea. Model 25HBC360A500 S/N 0612E13857
1 ea. Model 38AUQA12A0A5A0A0A0 S/N 0812C92107
(1) Carrier Direct Expansion Fan Coil unit with Warren Technology FCU Electric heater
1 ea. Model FB4CNF060 S/N 2312A82199 1 ea. Model WKF0902C No s/n given
DHR SOUTHWEST REGION 1 HVAC EQUIPMENT
(2) Exhaust Fans- Form D
Clarke Inspection Forms required to be completed & signed during all quarterly inspections: A, D
3. DHR Washington Co.
14921 ST. STEPHENS AVENUE
CHATOM, AL 36518
Ph: 251-847-6115 Ph: 251-847-6116
Description of System:
(6) SPLIT SYSTEM TRANE HEAT PUMPS WITH ELECTRIC DUCT HEAT- Form A Air handler units 1 ea. Model TWE060A300BA S/N G51170748
2 ea. Model TWE061D300AA S/N 13401NF4BA,14482JCWBA 3 ea. Model TWE090A300BA S/N G51170799, 10351NS3BA,10412WR9BA Condensers 2 ea. Model TWA090D30RAA S/N 9475RDCAD,11124L38YA 1 ea. Model 4AC3060A3000BA, S/N 10205MFY2F 1 ea. Model 4TWA3060B3000AA S/N 14093L874F 1 ea. Model TWA060C300A0 S/N G46258543 1 ea. Model TWA090A300BA, S/N G51198618
(1) ROOF MOUNTED EXHAUST FAN- Form D
(2) CEILING MOUNTED EXHAUST FANS- Form D Washington Inspection Forms required to be completed & signed during all quarterly inspections: A, D