About this file
This is an HVAC equipment inventory and inspection requirements document for the Alabama Department of Human Resources (DHR) East Central Region, detailing specifications across five county locations: Talladega, Tallapoosa, Chambers, Coosa, and Clay counties. The document provides comprehensive descriptions of existing HVAC systems at each DHR facility, including equipment models, serial numbers, and quantities. Talladega County houses the most extensive system with 25 heat pumps and 25 air handler units of varying tonnages (3.0 to 5 tons), plus one Mitsubishi mini-split system and seven exhaust fans. Tallapoosa County operates a central station system with two Carrier air handling units. Chambers County maintains five split system heat pump/condenser units, five VAV boxes, and six exhaust fans. Coosa County operates seven split system gas upflow furnaces paired with electric AC condensers, plus one electric split system air handler and seven exhaust fans. Clay County contains six split system gas upflow furnaces with electric cooling coils, six electric air condensers, one 10-ton two-stage gas furnace unit, and six exhaust fans. Equipment across all locations includes brands such as Lennox, Mitsubishi, Carrier, American Standard, Rheem, Bryant, and Trane.
The document specifies quarterly inspection requirements for all facilities, with required completion and signatures on designated inspection forms varying by location (Forms A, D, G, and K). No information is provided regarding pricing, bidding procedures, contract terms, renewal options, funding sources, or set-asides. The document serves as an equipment roster and maintenance protocol reference rather than a formal procurement solicitation, establishing baseline documentation for HVAC system conditions and ongoing inspection compliance across the DHR East Central Region facilities.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| DHR HVAC PM specifications 1-23-26 with revisions_ kg FINAL 4.20.26.docx | DOCX document | |
| DHR HVAC PM Site Visit Schedule.docx | DOCX document | |
| County Map DHR location_Site Visit Order_area.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DHR EAST CENTRAL REGION HVAC EQUIPMENT
1. DHR Talladega Co.
1010 ASHLAND HIGHWAY
TALLADEGA, ALABAMA 35160
Ph: 256-761-6605 Ph: 256-761-6601
DescripƟon of system:
Split System with Electric Heat pumps
(25) Heat pumps outdoor- Lennox- Form K
(25) Air handler indoor units -Lennox Form D
(1) Heat pump mini split, OD & Indoor -Mitsubishi-Model PLAA24BA6/PUZA24NHA6 Form K s/n 41A00373B/43001582B
(7) Exhaust fans in bathrooms- Form D
See directly below for addiƟonal informaƟon on Talladega’s 25 ea. Heat Pumps/25 ea. Air handler unit types:
(10) 4 Ton Heat pumps -MODEL TPA04854N44G SERIAL
5815GF03168,10066,10068,10070,10075,10076,10079 & 5815L05688
(10) 4-Ton fan Coil
(7) 5-Ton Heat Pumps- MODEL TPA06054N44G SERIAL5815K04102,K09366, 09368, 09372, 09380, 10126, 10132
(7) 5-Ton Fan Coil
(4) 3.5-Ton Heat Pump- MODEL TSA04254N43G SERIAL 5815G09976-09979
(4) 3.5-Ton Fan Coil
(1) 3.0 – Ton Heat Pump – Model TSA036S4N43G SERIAL 5813F01312
(2) 1.5-TON CONDENSER
(2) 1.5- TON FAN COIL
(1) 2-TON CONDENSER
(1) 2-TON FAN COIL - Model 14ACX-024230A17 SERIAL 1915M12574
Talladega InspecƟon Forms required to be completed & signed during all quarterly inspecƟons:
A, K & D
2. DHR Tallapoosa Co 1279 South Tallassee St Dadeville, AL 36853 Ph: 256-825-3718 Ph: 256-825-3729 DescripƟon of system:
1 ea. Indoor Central StaƟon AHU Carrier Model 39MN50W024YSR34 S/N 4417441749 1 ea. Outdoor Central StaƟon AHU Carrier Model 38MNADT06064A18084 S/N 4317Q60651 No boilers or chillers Tallapoosa InspecƟon Forms required to be completed & signed during all quarterly inspecƟons:
G & K
3. DHR Chambers Co
410 9TH AVENUE, SW
LAFAYETTE, AL 36862
Ph: 334-864-4026 Ph: 334-864-4056
DescripƟon of system:
5 ea. Split system heat pump/condenser units Brand name - All Carrier #1 Upstairs Split #1 outside
SERIAL # 0607A87059 2407E17008
MODEL # FC4DNF060 25HBR360A510
#2 Heat Pump upstairs #2 Split system outside Serial # 3506A88085 2407E17007 Model # FC4DNF060 25HBR360A510
#3 upstairs Split #3 outside
MODEL # FC4DNF060 25HBR360A510
SERIAL # 0607A87068 2407E17010
#4 heat pump outside #4 (split)upstairs Model# 38AUQA12AOA5AOAOAO 40RUQA12A2A6-0A0A0 Serial # 1417C90872 1317UO4364
#5 heat pump #5 outside
MODEL # FC4DNF048 25HBR348A520
SERIAL# 4106A88271 1507E40415
No boiler or chillers
5 ea. VAV Boxes 6 ea. Exhaust fans Chambers InspecƟon Forms required to be completed & signed during all quarterly inspecƟons:
Form A,G,D
4. DHR Coosa Co 141 Jackson St Rockford, Al 35136 Ph: 256-377-2005 Ph: 256-377-2000
DescripƟon of system:
7 ea. Split system Gas Up Flow Furnace Form A
(1) American Standard Model S8B1D120M5PSAAA S/N 191856GWHG 10 TON
(1) American Standard Model TUD100C960J1 S/N R31115D2G
(3) American Standard (3A & B) Model TUD100C972J0 S/N P464W451G & P416PUP1G
S/N P39322E1G
(1) Rheem Model R801PA125524MSA S/N W331431257
(1) Bryant Model 310AAAV048090 S/N 4918A21227 7 ea. Electric AC condensers American Standard Model 4A7C4060A3000A S/N 1937304K5F Model 4TTA3048D3000CA S/N 141237F73F Model TTA120A300DA S/N R372130AH Model 2TTA0060A3000AA S/N 72256HJ3F Model 4TXCD010DS3HCA S/N S19074Y98CG Rheem Model RA1360AC1NB S/N W031510801 Bryant Condenser Model 1113A9A042000 S/N 3818E03050 Evaporator Model CAPM94221ALA S/N 4718X37606 1 ea. Electric Split system Air Handler unit Form A American Standard Model 4A7C4060A3000A S/N S1928271J5F No boilers, chillers or cooling towers.
7 ea. Exhaust fans Form D Coosa InspecƟon Forms required to be completed & signed during all quarterly inspecƟons:
Form A, D
5. DHR Clay Co 86930 Highway 9 Lineville, AL 36266 Ph: 256-396-6832 Ph: 256-396-6837 DescripƟon of system:
Split System unit with gas heat
6 ea. Split system Gas Up flow Furnace with Electric cooling coils Form A 3 American Standard Model AUD100C972H4 S/N
P0453XA1G,P0453XE1G,P071SN01G
1 American Standard Model AUD100C945H4 S/N P051SAF2
1 Trane Model D345884807 S/N 1908091457177 1 Trane Model S8X1D1Z0M5PSBAA S/N 205041PXHG
6 ea. Electric Air Condensers 3 American Standard Model 7C0060A300A1 S/N N392MH4CF,N392MJ3CF,M392MJXCF
1 American Standard Model 7C0042A300A2 S/N P032531CF 1 Trane XR Model 4TTA4060A3000AA S/N N392MJXCF?
1 Trane Model 4TTA4060A3000AA S/N 21247GMG4F
1 ea. 10 Ton Trane 2 Stage HeaƟng Gas Furnace Unit 1A Model AUD2D120B9VVBA S/N 21013JD1GG Unit 1B Model AUD2D120B9VVBB S.N 21013JDYGG 6 ea. Exhaust fans Form D No boilers, chillers or cooling towers Clay InspecƟon Forms required to be completed & signed during all quarterly inspecƟons: A, D