Project_Drawings.pdf
PDF 24 MB Posted
- Attached to
- COMM. TOWERS, BLDGS, SITEWORK Federal contract opportunity
- Solicitation number
- DE-SOL-0008115
About this file
Project Drawings
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment_002_Final.pdf | ||
| Amendment_001.pdf | ||
| Contract_Clauses_and_Bid_Schedule.pdf | ||
| Project_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COMMUNICATION TOWERS, BUILDINGS, AND SITE WORK
VARIOUS LOCATIONS
SOUTH DAKOTA, NORTH DAKOTA, AND NEBRASKA
SECTION C
DESCRIPTION/SPECIFICATIONS
Solicitation No. DE-SOL-0008115 Spec. No. 15WC111528-671
DIVISION 15 – DRAWINGS
A. GENERAL:
CONSTRUCTION STANDARD DRAWINGS: A complete set of standard drawings are available at http://www.wapa.gov/business/buys.htm. Construction drawings are the specification drawings and any additional drawings required for use in construction. The construction drawings will be issued after contract award and may include amendment changes and other details, which make the drawings suitable to use for construction purposes.
PROJECT DRAW INGS: Project drawings included herein are reduced reproductions and are not to scale.
Some project drawings show details of fabrication and other information not a part of the work. Disregard information and details, which are not applicable.
STANDARD DRAW INGS: W here details shown on standard drawings included herein differ from project drawings or text, the details of project drawings or text shall govern.
INFORMATIONAL DRAW INGS: Some project drawings have the words “FOR INFORMATION ONLY” appearing above the title block. These drawings show some information, which may be required for bidding purposes. These drawings do not show items to be furnished or work to be performed.
EXISTING INSTALLATION DRAWINGS: Some project drawings have the words “EXISTING INSTALLATION” appearing above the title block. These drawings show the existing installations prior to modifications and may show some new work to be performed.
REFERENCE DRAW INGS: Reference drawings referred to on project drawings and not included herein, are not necessary for bidding purposes.
CONTRACTOR'S RESPONSIBILITY: Check all drawings and advise Western of any errors or omission.
B. LIST OF DRAWINGS:
ARMOR SUBSTATION
1. AR 0016 – Rev D – Location and Vicinity Map
BISMARCK SUBSTATION
2. BS 0019 – Rev A – Location and Vicinity Map
HURON MAINTENANCE FACILITY
3. HUM 0015 – Rev C – Location and Vicinity Map
BIJOU HILLS MICROWAVE SITE
4. BJR 0015 – Location and Vicinity Map
5. COM BBJR 7101 – Topography
6. BJR 7102 – Rev D – General Plot Plan
7. BJR 2875 – Rev A – Comm Tower Elevations
CLARK REPEATER
8. CKR 7000 – Rev A – Location and Vicinity Map
9. COM BCKR 7102 – Topography
10. CKR 7012 – Rev A – General Plot Plan
COLMAN REPEATER
11. CLM 0015 – Location and Vicinity Map
12. CB1068 – Concrete Base, Pivoted
13. CA 1030 – Concrete Anchor
CROW LAKE REPEATER
14. CLR 0015 – Location and Vicinity Map
ELLIOT SUBSTATION
15. ELI 0015 – Location and Vicinity Map
16. ELI 1000 – Rev A – General Arrangement Plan (Existing Installation)
17. ELI 1000 – Rev B – General Arrangement Plan
18. ELI 1500 – Grounding Plan (Existing Installation)
19. ELI 1500 – Rev A – Grounding Plan
20. ELI 2200 – Rev A – Foundation Plan (Existing Installation)
21. ELI 2200 – Rev B – Foundation Plan
22. ELI 7012 – General Plot Plan
23. ELI 7013 – Waveguide Bridge Detail
24. ELI 7101 – Tower Layout
25. SST2087 – 20 Ft. SS20T Section
26. SST2088 – 20 Ft. SS20T Section
27. SST2089 – 20 Ft. SS20T Section
28. SST2090 – 20 Ft. SS20T Section
29. SST2091 – 20 Ft. SS20T Section
30. ELI 7104 – Foundation Layout http://www.wapa.gov/business/buys.htm
HURON SUBSTATION
31. HU 0015 – Rev C – Location and Vicinity Map
32. HU 0010 – Rev C – General Plot Plan
33. HU 0018 – Topography
KONES CORNER MICROWAVE SITE
34. KCR 0015 – Location Map
35. KCR 2051 – Rev B – Grading Plan
36. KCR 7010 – 199 Foot Guy – Tower Outline
LAKE ANDES REPEATER
37. LKR 0015 – Location and Vicinity Map
38. COM BLKR 7101 – Rev A – Topography
39. LKR 7102 – Rev E – General Plot Plan
MOE MICROWAVE SITE
40. MOX 0015 – Location and Vicinity Map
41. COM BMOX 7101 – Topography
42. COM BMOX 7102 – Grading Plan
43. COM BMOX 7103 – General Plot Plan
44. MSS3044 – Master Self-Supporting Tower: 120FT
45. CB1070 – Concrete Base for Self-Supporting Tower
46. ABL1038 – Anchor Bolt Layout
47. SST2086BS – 20 FT SS20T Section
48. SST2087 – 20 FT SS20T Section
49. SST2088 – 20 FT SS20T Section
50. SST2089 – 20 FT SS20T Section
51. SST2090 – 20 FT SS20T Section
52. SST2091 – 20 FT SS20T Section
53. WSI5512 – Waveguide Support Installation
54. LSD2001 – Leg Splice Detail
55. TLI5011 – Tower Ladder Installation
56. MIS4024 – Leg Cap Installation
57. MIS4049 – Ladder Base Installation
58. CB1074 – Waveguide Channel Support Footing
59. CB1064 – Propane Tank Footing
60. AMI6579 – Antenna Mntg. Install
61. SPP1063 – Plot Plan – Page 1 of 2
62. SPP1063 – Plot Plan – Page 2 of 2
63. TGI1528 – Grounding Installation
64. MIS4092 – Platform Installation
65. MIS4093 – Platform Installation
ORCHARD RADIO RELAY STATION
66. OR 0015 – Location and Vicinity Map
67. OR 7101 – Topography
68. OR 7100 – General Plot Plan
69. OR 2300 – Foundations – Outline and reinforcement
70. 34163E01 – Spread Footing Foundation 175’ EEI SSTA
71. 34163E02 – Foundation and Templates
72. 34163E03 – 175’ EEI Model SSTA Installation Details
73. 34163E06 – Section SS20TA5S – EL. – 140’ – 160’ Erection Drawing
74. 34163E07 – Section SS15TA5S – EL. – 160’ – 175’ Erection Drawing
75. 34163E08 – Ladder Installation Drawing
76. 34163E09 – Waveguide Ice Bridge Installation
PUKWANA MICROWAVE SITE
77. PUR 0015 – Location and Vicinity Map
78. COM BPUR 7101 – Topography
79. COM BPUR 7102 – Rev A – General Plot Plan
80. SPP1051 – Plot Plan – Page 1 of 2
81. MSS3041 – Master Self-Supporting Tower: 120FT
82. SST2075BS – 20 FT SS20T Section
83. SST2076 – 20 FT SS20T Section
84. SST2077 – 20 FT SS20T Section
85. SST2078 – 20 FT SS20T Section
86. SST2079 – 20 FT SS20T Section
87. SST2080 – 20 FT SS20T Section
88. CB1070 – Concrete Base for Model SS20T
89. ABL1035 – Anchor Bolt Layout
SNAKE BUTTE MICROWAVE SITE
90. SNA 0015 – Location and Vicinity Map
91. AGB5228 – Exterior Elevations for 12’W x 20’L X 9’H Bldg
92. 15B2133G – Building Skid Assembly for 12’W X 20’L Bldg
TRIPP MICROWAVE SITE
93. TRP001 – Tripp Microwave – Cover Sheet
94. TRP002 – Tripp Microwave – Site Plan
TURKEY RIDGE REPEATER
95. TU 7001 – Rev A – Location and Vicinity Map
96. TU 7002 – Rev A – Topography
97. TU 7003 – Rev C – General Plot Plan
WESSINGTON SPRINGS MICROWAVE SITE
98. WSR 7014 – Location map
99. COM BWSR 7101 – 113 FT. TJ – AA Tower
ORCHARD, SD
At Western, we show our co and the work conditions we p who provide products or serv right decisions to ensure that
Our safety program is based o
Safety procedures or common not be set aside to meet a proj
Employees and contractors m action to reduce, if not elimin
Managers and supervisors mu accomplished in a safe and he
Safety is a personal responsib a task.
By integrating these principle work.
ommitment to safety every day through th provide. We expect the same commitmen vices to Western. In performing work for the work environment is as safe as possib on four points:
n sense must be applied by each Federal a oject schedule or for personal convenience must believe that they have the right and th nate, hazardous work environments and h ust lead by example and execute their res ealthy way.
bility. Each individual makes the decisio es into every task we take, together we ca he actions we take, the training we offer nt to safety from each of our contractors r Western, all contractors must make the ble.
and contract employee. Safety should e.
he responsibility to identify and take hazardous work practices.
ponsibility to ensure each job is n on what action to take to accomplish an ensure Western is a safe place to
Mark A. Gabriel Administrator
File details come from the government source that posted it. Updated .