Description of Requirement 990 Generator.pdf

PDF 216 KB Posted

Attached to
Brand Name Soliciation- Cummins Inc. DFEJ Commercial Diesel Generator Set
Solicitation number
W50S85-25-Q-A026
Issued by

About this file

The document is a detailed Description of Requirement for a DFEJ Commercial Diesel Generator Set, specifically a 350kW Standby 60Hz generator for U.S. EPA Stationary Emergency Application. The generator is a Cummins model with comprehensive specifications including EPA Tier 2 emission certification, UL 2200 listing, 277/480V three-phase electrical configuration, a 850-gallon sub-base fuel tank, steel sound-attenuated green enclosure, and wind rating of 150 MPH. Additional features include a PowerCommand 2.3 controller, LCD display, emergency stop switch, external battery charger, coolant heater, and a 2-year base warranty. The generator is designed for stationary emergency power applications with precise technical requirements for electrical, mechanical, and environmental performance characteristics.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description of Requirement

Provide the Description of all of the salient physical, functional or performance characteristics that the item must meet to be acceptable for award: (be as detailed as possible)

Item Description:

Salient characteristics - defined and sample **double-click icon

Salient Characteristics

Salient characteristics means those qualities of an item that are essential to ensure that the intended use of the item can be satisfactorily realized. The term sets forth those salient physical, functional, or other characteristics of the referenced product that an equal product must have in order to meet the recipient’s needs. They cannot unduly restrict competition.

Detailed product specifications should be avoided if at all possible. When it is impractical or uneconomical to make a clear and accurate description of the technical requirements, a referenced make or model number may be used as a means to define other salient characteristics of a procurement. Specific features that must be met by offerors shall be clearly stated.

Distinguishing characteristics of the product can include:

• Reference to an existing make/model number

• Including descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information

• Any specifications, dimensions, color

Example

We have a requirement to purchase bandages. Our baseline is the Band-Aid brand bandage. Salient characteristics are:

• Flexible, sterile adhesive bandages

• Safety center pads

• Individually wrapped

• Between 1-3/4 inches wide and 3 inches long

Using these salient characteristics would allow for offers of numerous bandages other than Band-Aid.

1093598390N File Attachment Salient characteristics.pdf

Enter Text: DFEJ Commercial Diesel Generator Set, 350kW Standby 60Hz U.S. EPA, Stationary Emergency Application 350DFEJ, Diesel Genset, 60Hz, 350kW-Standby Rating Duty Rating - Standby Power (ESP) Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency Listing - UL 2200 Voltage - 277/480, 3 Phase, Wye, 4 Wire Alternator - 60Hz, 12 Lead, Limited Range, 125/105C Steel Sound Attenuated Level 1 Enclosure, with Exhaust System Enclosure Color - Green, Steel Wind Rating - 150 MPH, Steel Housing Fuel Tank - Sub Base, 850 Gallon, UL142 Compliant Compliance - Fuel Tank, Michigan Listing, ULC - S601 - 07 Alarm - High Fuel Level, External with OFPV Override Fuel Water Separator Spill/Fill Box - Fuel with OFPV Vent Extension - Fuel Tank, 5 Inch Diameter Control Mounting - Left Facing PowerCommand 2.3 Controller LCD Control Display Stop Switch - Emergency, Externally Mounted Signals - Auxiliary, 8 Inputs/8 Outputs Control Display Language - English Circuit Breaker or Entrance Box or Terminal Box - Right Only Circuit Breaker or Entrance Box or Terminal Box, Left - None Circuit Breaker - 600A, Right Circuit Breaker on Right side, 3 - Pole, UL 600, IEC 690, 100% Circuit Breaker or Entrance Box or Terminal Box, Left - None tion: SANG Base Building 990 Cummins Proposal Bottom Entry, Right Engine Exhaust Connection - None Engine Air Cleaner - Normal Duty External Battery Charger - 12 Amp, Regulated Engine Cooling - Radiator, 40C Ambient Shutdown - Low Coolant Level Coolant Heater - 208/240/480 Volts AC, Below 40F Ambient Temperature Genset Warranty - 2 Years Base Literature - English Packing - None, Base Mounted Housing