This document is a set of architectural and systems drawings for an audiovisual (AV) installation at the U.S. Department of Veterans Affairs facility located at 4150 Clement Street, San Francisco, CA 94121, identified under Project Order #662-C24059.

The drawings provide detailed specifications for an auditorium AV system installation, including floor plans, equipment layouts, and infrastructure requirements. The design encompasses an Auditorium 112 with an associated rack room for equipment housing. Key components include multiple 70-volt ceiling speakers (S1-S8) distributed throughout the auditorium space, wall-mounted equipment boxes at various heights (WP1-WP3 for wall panels at 80", 60", and 42" above finished floor, FP1 for floor panel, and AV1 for equipment at 18" AFF), a lectern position with audio connectivity, and a front wall video display system. The system incorporates multiple conduit runs for audio and control signal distribution, with specified excess cable lengths for speaker homerun connections and equipment integration. System infrastructure includes wall-mounted touch panels for control, ceiling speaker mounting provisions, and equipment rack configuration in the dedicated rack room. The drawings employ standard AV industry symbols and legends to denote electrical connections, device types, conductor specifications, and mounting methodologies. Original drawings date to 08.30.2025 with revision 3 dated 11.21.2025, prepared by Solutionz, Inc.

View the file

Other files

File Type Posted
36C26126Q1096.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U.S. Department Of Veterans Affairs 4150 Clement Street - San Francisco, CA 94121

PO# 662-C24059

© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE

CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE

DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF

SOLUTIONZ, INC.

SOLUTIONZ, INC.

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

ORIGINAL ISSUE DATE

AutoCAD SHX Text

REVISION LEVELL

AutoCAD SHX Text

LATEST REVISION ISSUE DATE

AutoCAD SHX Text

AV-100

AutoCAD SHX Text

TITLE PAGE - DRAWING INDEX

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-300

AutoCAD SHX Text

ONE LINE DRAWING LEGEND

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-301

AutoCAD SHX Text

AUDIO ONE LINE

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-401

AutoCAD SHX Text

VIDEO & CONTROL ONE LINE

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-900

AutoCAD SHX Text

TYP AV SYSTEM STANDARD PINOUT DETAILS

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-901

AutoCAD SHX Text

TYP AV SYSTEM STANDARD PINOUT DETAILS

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-902

AutoCAD SHX Text

PROJECT PIN OUT DETAILS

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

AV-903

AutoCAD SHX Text

PROJECT PIN OUT DETAILS

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

ORIGINAL ISSUE DATE

AutoCAD SHX Text

REVISION LEVELL

AutoCAD SHX Text

LATEST REVISION ISSUE DATE

AutoCAD SHX Text

AV-100

AutoCAD SHX Text

TITLE PAGE - DRAWING INDEX

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 11.21.2025

AutoCAD SHX Text

AV-200

AutoCAD SHX Text

BUILDING PLAN LEGEND

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 11.21.2025

AutoCAD SHX Text

AV-201

AutoCAD SHX Text

AUDITORIUM 112 - FLOOR PLAN

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 11.21.2025

AutoCAD SHX Text

AV-202

AutoCAD SHX Text

AUDITORIUM 112 - EQUIPMENT LAYOUT

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 11.21.2025

AutoCAD SHX Text

AV-501

AutoCAD SHX Text

RISER DIAGRAM

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

AutoCAD SHX Text 11.21.2025

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

ORIGINAL ISSUE DATE

AutoCAD SHX Text

REVISION LEVELL

AutoCAD SHX Text

LATEST REVISION ISSUE DATE

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text EACH DEVICE IN AN AV SYSTEM ARE GIVEN AN IDENTIFYING DEVICE TYPE ABBREVIATION AND NUMBER COUNTING THE QUANTITY OF THAT DEVICE WITHIN THAT SYSTEM. SEE AV-300 FOR THE DEVICE ABBREVIATION LEGEND. DEVICE ID'S ARE USED THROUGHOUT THE AV DRAWING SET.

AutoCAD SHX Text

DEVICE ID LEGEND

AutoCAD SHX Text

DDD-XXX

AutoCAD SHX Text

DEVICE QUANITY

AutoCAD SHX Text

DEVICE TYPE ABBREVIATION

AutoCAD SHX Text DEVICE ID'S AND CABLES IN AN AV SYSTEM ARE GIVEN A UNIQUE NUMBER PER SYSTEM. SELF-CONTAINED SYSTEMS THAT DO NOT TIE TO A MASTER ARE ONLY UNIQUE WITHIN THAT SUB-SYSTEM. BECAUSE OF THIS VARIOUS ROOMS (SYSTEMS) ON FLOOR PLANS AND RCP'S MAY HAVE SIMILAR DEVICE ID'S. THIS HELPS TRACKING AND UNDERSTANDING MULTIPLE SUB-SYSTEMS TO HAVE SIMILAR DEVICES AND ID'S HANDLED THE SAME IN EACH ROOM (SYSTEM).

AutoCAD SHX Text

NUMBERING SEQUENCE

AutoCAD SHX Text

DRAWING SERIES LEGEND

AutoCAD SHX Text

AV-000 TO AV-099

AutoCAD SHX Text

NOT USED

AutoCAD SHX Text

AV-100 TO AV-199

AutoCAD SHX Text

TITLE AND DRAWING INDEX

AutoCAD SHX Text

AV-200 TO AV-299

AutoCAD SHX Text

BUILDING PLANS, LAYOUTS, RISERS

AutoCAD SHX Text

AV-300 TO AV-399

AutoCAD SHX Text

SYSTEM ONE LINE DRAWINGS - NON COMPLEX A/V/C COMBINED

AutoCAD SHX Text

AV-300 TO AV-399

AutoCAD SHX Text

AUDIO ONE LINE DRAWINGS - COMPLEX

AutoCAD SHX Text

AV-400 TO AV-499

AutoCAD SHX Text

VIDEO ONE LINE DRAWINGS - COMPLEX

AutoCAD SHX Text

AV-500 TO AV-599

AutoCAD SHX Text

CONTROL ONE LINE DRAWINGS - COMPLEX

AutoCAD SHX Text

AV-600 TO AV-699

AutoCAD SHX Text

EQUIPMENT RACK, CABINET, CREDENZA ELEVATIONS

AutoCAD SHX Text

AV-700 TO AV-799

AutoCAD SHX Text

I/O PLATES, PANEL LAYOUTS, PATCHBAY LAYOUTS

AutoCAD SHX Text

AV-800 TO AV-899

AutoCAD SHX Text

MECHANICAL DETAILS, WALL/CEILING/FLOOR MOUNTING DETAILS

AutoCAD SHX Text

AV-900 TO AV-999

AutoCAD SHX Text

WIRING DIAGRAMS, PINOUT DETAILS, CUSTOM CABLING DETAILS

AutoCAD SHX Text

SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018

AutoCAD SHX Text

TITLE PAGE - DRAWING INDEX

AutoCAD SHX Text AV 45349.v-100

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

ORIGINAL DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

PM:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

AutoCAD SHX Text

SYSTEM ID

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

I3 FEDERAL

AutoCAD SHX Text

DEPT OF VA, SAN FRANCISCO CA

AutoCAD SHX Text 45349.v

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text Kate Eneria

AutoCAD SHX Text Daniel Urquiola

AutoCAD SHX Text Kirsi Ruotsala

AutoCAD SHX Text

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

UPDATED AUDIO COVERAGE

AutoCAD SHX Text

AutoCAD SHX Text 11/21/2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

FLOOR PLAN / RISER

AutoCAD SHX Text FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322

M O N I T O R

S I D E

© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE

CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE

DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF

SOLUTIONZ, INC.

SOLUTIONZ, INC.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SPEAKER TYPES

AutoCAD SHX Text

SCREEN/LIFT TYPES

AutoCAD SHX Text

WALL TOUCH PNL TYPES

AutoCAD SHX Text

AV DEVICE OR BOX - WALL, CEILING, FLOOR

AutoCAD SHX Text

CABLE QTY/WIRE TYPE

AutoCAD SHX Text

CABLE ROUTING INFO

AutoCAD SHX Text

CONDUIT SIZE/NOTE

AutoCAD SHX Text Q

AutoCAD SHX Text T

AutoCAD SHX Text 3/4"

AutoCAD SHX Text

XX

AutoCAD SHX Text

AV BUILDING INFRASTRUCTURE SYMBOL LEGEND

AutoCAD SHX Text

WALL

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text JUNCTION BOX WITH COVER PLATE FOR AV CONNECTION. PROVIDED BY E.C. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT UNLESS OTHERWISE INDICATED. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG. SEE GANG BOX TYPE LIST.

AutoCAD SHX Text JUNCTION BOX FOR A/V CONNECTIVITY. SEE JUNCTION BOX TYPES LIST AND WALL BOX MOUNTING METHODS.

AutoCAD SHX Text JUNCTION BOX FOR WALL/CEILING CAMERA LOCATIONS. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT. SUB-NUMBER INDICATES NUMBER OF GANG.

AutoCAD SHX Text

SPECIAL OUTLET

AutoCAD SHX Text

DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.

AutoCAD SHX Text

TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.

AutoCAD SHX Text

POTS TELCO ANALOG PHONE LINE

AutoCAD SHX Text

POKE THRU LOCATION

AutoCAD SHX Text

DUPLEX OUTLET, 3 PIN EDISON U.O.N.

AutoCAD SHX Text

QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.

AutoCAD SHX Text

SINGLE WALL OUTLET, 3 PIN EDISON

AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING

AutoCAD SHX Text

ISOLATED GROUND

AutoCAD SHX Text

DEDICATED CIRCUIT

AutoCAD SHX Text

DEDICATED CIRCUIT WITH ISOLATED GROUND

AutoCAD SHX Text W

AutoCAD SHX Text

FB

AutoCAD SHX Text C

AutoCAD SHX Text

JB

AutoCAD SHX Text

CAM

AutoCAD SHX Text

CAM

AutoCAD SHX Text 20A

AutoCAD SHX Text 20A

AutoCAD SHX Text

TV

AutoCAD SHX Text

TV

AutoCAD SHX Text

TV

AutoCAD SHX Text

IG

AutoCAD SHX Text D

AutoCAD SHX Text

D/IG

AutoCAD SHX Text

IG

AutoCAD SHX Text D

AutoCAD SHX Text

D/IG

AutoCAD SHX Text

IG

AutoCAD SHX Text D

AutoCAD SHX Text

D/IG

AutoCAD SHX Text

1. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. 2. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. 3. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 4. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. 5. THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH ARCHITECT FOR ALL DEVICE LOCATIONS. 6. SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, ELECTRICAL WIRING IS TO BE PROVIDED BY THE PROJECT DIVISION 16 CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX CONDUIT SHALL NOT BE CONSIDERED ACCEPTABLE. 8. E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT SHALL BE DE-BURRED, CLEANED, CAPPED. CONDUIT STUB-OUTS, JUNCTION BOXES, AND OUTLETS SHALL BE SUITABLY LABELED FOR IDENTIFICATION OF FUNCTION, J-BOX #, AND/OR CONDUIT NUMBER. 9. E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING INSPECTIONS. 10. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. 11. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. 12. INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR LARGER. 13. INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" OR LESS. 14. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. 15. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. 16. ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE NOT ACCEPTABLE. ACCEPTABLE. 17. FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX WITH APPROPRIATE PLASTER RING EXTENSION U.O.N. 18. EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, POWER WIRE AND POWER CONNECTIONS UNDER THIS SECTION. DEVICE PLATES AND CONNECTOR PANEL INFORMATION IS FOUND IN THE AV-700 SET OF DRAWINGS. 19. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 20. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. 21. ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES CONNECTED WITH MINIMUM 3/4"C. 22. REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH DESIGN ARCHITECT. 23. FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING PROPER NOTICE. 24. WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR ROUGH-IN AND CONDUIT TERMINATION. 25. WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, OUTLETS, WIRE WAYS, PANELS, ETC., ARE TO BE IDENTIFIED ON COORDINATION DRAWINGS FOR REVIEW ACCORDING TO PROJECT GENERAL CONDITIONS. 26. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. 27. CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE SURFACE MOUNTED, CONDUIT SHALL ENTER FROM THE REAR OF THE BOX. 28. REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF VARIOUS DEVICES. 29. CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE OR AS REQUIRED BY SITE CONDITIONS. 30. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. 31. FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND AN ACCESSIBLE PULL BOX FOR MORE THAN TWO 90 DEGREE BENDS IN A CONDUIT RUN. 32. THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO CONDUIT SYSTEM TO ACCOMMODATE SITE CONDITIONS OR SIMPLIFY INSTALLATION AS LONG AS ADEQUATE SIZING IS MAINTAINED AND THE SYSTEM INSTALLER AND ARCHITECT APPROVE THE COORDINATION DRAWINGS SUBMITTED FOR REVIEW. 33. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. 35. POWER JUNCTION BOX. SURFACE MOUNT AT 96" A.F.F. PROVIDE 20A CIRCUITS WITH DEDICATED NEUTRALS AND OVERSIZED GROUND BACK TO PANEL "AV". LEAVE CIRCUIT TAIL AT 20' LENGTH FOR TERMINATION TO "AV", "TV", "ER" TYPE RACKS 36. MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH ARCHITECT. 37. PROJECTION SCREEN BACKBOX PROVIDED BY A/V AND INSTALLED BY GC. PROVIDE GANG BOX CONNECTIONS FOR LOW-VOLTAGE CONTROL AND MOTOR POWER FROM NEAREST POWER PANEL. SCREENS TO BE CONTROLLED BY A/V. 38. L/V CONTRACTOR TO PULL, TERMINATE, AND TEST ALL RISER AND DISTRIBUTION CABLING INCLUDING FIBER, AND NETWORK CATEGORY CABLES.

AutoCAD SHX Text -------CONTRACTORS------- A/V = PROJECT DIVISION 11 (SUB)CONTRACTOR. E.C. = PROJECT DIVISION 16 (SUB)CONTRACTOR. LVC = PROJECT LOW VOLTAGE (SUB) CONTRACTOR. -------MOUNTING LOCATION/ORIENTATION------- AFC = ABOVE FINISHED CEILING AFF = ABOVE FINISHED FLOOR B.C.P. = BLANK COVER PLATE BCS = BELOW COUNTER-TOP SURFACE BFC = BELOW FINISHED CEILING BFF = BELOW FINISHED FLOOR BOB = BOTTOM OF BOX COB = CENTER OF BOX SRH = PROJECT STANDARD RECEPTACLE HEIGHT SSH = PROJECT STANDARD SWITCH HEIGHT HT. = HEIGHT RU = RACK UNIT ( 1.75" HIGH x 19.25" WIDE ) -------STAGE/HOUSE DIRECTIONS------- BOH = BACK OF HOUSE BOH-L = BACK OF HOUSE LEFT BOH-R = BACK OF HOUSE RIGHT CS = CENTER STAGE (MID STAGE) DSC = DOWN STAGE CENTER DSL = DOWN STAGE LEFT DSR = DOWN STAGE RIGHT FOH = FRONT OF HOUSE FOH-L = FRONT OF HOUSE LEFT FOH-R = FRONT OF HOUSE RIGHT HC = HOUSE CENTER HL - HOUSE LEFT HR = HOUSE RIGHT SL = STAGE LEFT SR = STAGE RIGHT USC = UP STAGE CENTER USL = UP STAGE LEFT USR = UP STAGE RIGHT -------SIGNAL GROUPS------- A = AUDIO LEVEL SIGNAL V = VIDEO TYPE LEVEL SIGANAL C = CONTROL LEVEL SIGNAL H = HI RESOLUTION VIDEO SIGNAL F.O. = FIBER OPTIC RF = RADIO FREQUENCY SIGNAL -------TELECOMMUNICATIONS------- IDF = INTERMEDIATE DISTRIBUTION FACILITY IP = INTERNET PROTOCOL LAN = LARGE AREA NETWORK MDF = MAIN DISTRIBUTION FACILITY MDP= MATV DISTRIBUTION PROCESSOR VLAN = VIRTUAL LAN WAN = WIDE AREA NETWORK WAP = WIRELESS ACCESS POINT -------ELECTRICAL/POWER/RELAYS/SWITCHING------- e.c. EMPTY CONDUIT I.G. = ISOLATED GROUND (TECHNICAL GROUND) I.P. = ISOLATED POWER (BALANCED POWER) n.o. = NORMALLY OPEN CONTACT n.c. = NORMALLY CLOSED CONTACT -------DEVICE/INPUT/OUTPUT------- C.P. = COVER PLATE CH = CHANNEL COMB = COMBINER CSP = CONTROL SYSTEM PROCESSOR DSP - DIGITAL SIGNAL PROCESSOR DVP = DIGITAL VIDEO PLAYER ER = EQUIPMENT RACK ex. = EXISTING EQUIPMENT MOD = MODULATOR RX = RECEIVE SERV = SERVER TP = TOUCH PANEL TX - TRANSMIT VDP = VIDEO DISTRIBUTION PROCESSOR -------PROVISIONS--------- O.F.E. = OWNER FURNISHED EQUIPMENT O.F.O.I. = OWNER FURNISHED, OWNER INSTALLED O.F.C.I. = OWNER FURNISHED, CONTRACTOR INSTALLED C.F.O.I. = CONTRACTOR FURNISHED, OWNER INTALLED C.F.C.I. = CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C.F.E.I = CONTRACTOR FURNISHED, ELECTRICAL INSTALLED E.F.E.I = ELECTRICAL FURNISHED, ELECTRICAL INSTALLED -------MISC------- AR = AS REQUIRED BY DOCUMENTS AS = AS SHOWN ON DRAWINGS CL = CENTER LINE IP = IPOD MB = MOUNTING BRACKET N.I.C. = NOT IN CONTRACT (FUTURE OR BY OTHERS) N/A = NOT APPLICABLE n/c = NO CONNECTION N/R = NOT REQUIRED N/U = NOT USED POE = POWER OVER ETHERNET QM = QUICK MEDIA RK = RACK KIT S.F. = STERILE FIELD T.B.D. = TO BE DETERMINED U.O.N. = UNLESS OTHERWISE NOTED

AutoCAD SHX Text

ABBREVIATIONS

AutoCAD SHX Text

KEYED ELECTRICAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text

AV SYSTEM DEVICE SYMBOL LEGEND

AutoCAD SHX Text

WALL

AutoCAD SHX Text

CEILING

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text (WP=WALL PLATE, CP=CEILING PLATE, FP=FLOOR PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR AV CONNECTION. PROVIDED BY AVC. MOUNT FLUSH WITH FINISHED BOX OR LV RING. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG.

AutoCAD SHX Text (BP=BOX PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR A/V CONNECTIVITY. CUSTOM PLATE IS DESIGNED WITH 1" ALL AROUND LARGER FLANGE TO COVER ROUGH OPENING AT JUNCTION BOX.

AutoCAD SHX Text CAMERA LOCATION. MOUNT MAY BE TO AN INSTALLED BOX OR MOUNTING PROVIDED WITH DISPLAY MOUNT OR MILLWORK.

AutoCAD SHX Text

SPECIAL OUTLET

AutoCAD SHX Text

DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.

AutoCAD SHX Text

TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.

AutoCAD SHX Text

POTS TELCO ANALOG PHONE LINE

AutoCAD SHX Text

WALL MOUNTED CONTROL TOUCH PANEL

AutoCAD SHX Text

WALL MOUNTED KEY PAD

AutoCAD SHX Text

POKE THRU PLATE

AutoCAD SHX Text

MICROPHONE LOCATION

AutoCAD SHX Text

OCCUPANCY SENSOR

AutoCAD SHX Text

ANTENNA

AutoCAD SHX Text

WIRELESS ACCESS POINT

AutoCAD SHX Text

INFRARED TRANSCEIVER

AutoCAD SHX Text

ELEVATION DETAIL CALL OUT. ARROW POINTS TO VIEWED DIRECTION ON DETAIL DRAWING.

AutoCAD SHX Text

DUPLEX OUTLET, 3 PIN EDISON U.O.N.

AutoCAD SHX Text

QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.

AutoCAD SHX Text

SINGLE WALL OUTLET, 3 PIN EDISON

AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING

AutoCAD SHX Text

REVISION NOTE

AutoCAD SHX Text

SHEET NOTE

AutoCAD SHX Text

WP

AutoCAD SHX Text

FP

AutoCAD SHX Text

CP

AutoCAD SHX Text

BP

AutoCAD SHX Text 20A

AutoCAD SHX Text 20A

AutoCAD SHX Text

TV

AutoCAD SHX Text

TV

AutoCAD SHX Text

TV

AutoCAD SHX Text P

AutoCAD SHX Text

JB

AutoCAD SHX Text

SCREEN CASE DRAWN TO SCALE

AutoCAD SHX Text

PROJECTOR SYMBOL NOT TO SCALE

AutoCAD SHX Text

PROJECTED LIGHT PATH

AutoCAD SHX Text

LENS CENTER LINE

AutoCAD SHX Text

CEILING MOUNTED

AutoCAD SHX Text

PROJECTOR/SCEEN

AutoCAD SHX Text

SPKR

AutoCAD SHX Text

CEILING SPEAKER

AutoCAD SHX Text

APROX COVERAGE PATTERN 4' AFF

AutoCAD SHX Text 40°

AutoCAD SHX Text

APROX COVERAGE PATTERN

AutoCAD SHX Text

SPKR

AutoCAD SHX Text

WALL MOUNTED SPEAKER

AutoCAD SHX Text

MOUNTING STYLES

AutoCAD SHX Text J-Box

AutoCAD SHX Text J-Box

AutoCAD SHX Text J-Box

AutoCAD SHX Text

HEIGHT AS SPECIFIED B.F.C.

AutoCAD SHX Text

JUNCTION BOX STYLES & ORIENTATIONS

AutoCAD SHX Text

HEIGHT AS SPECIFIED A.F.F.

AutoCAD SHX Text

VERTICAL

AutoCAD SHX Text J-Box

AutoCAD SHX Text

HORIZONTAL

AutoCAD SHX Text

WALL

AutoCAD SHX Text C

AutoCAD SHX Text

DEVICE SYMBOL

AutoCAD SHX Text

CONDUCTOR TAGS AND CONDUIT SYMBOLS

AutoCAD SHX Text

FUNCTION

AutoCAD SHX Text

DRAWING REFERENCE

AutoCAD SHX Text

WALL BOX MOUNTING METHODS

AutoCAD SHX Text

SLAB BOX/CONDUIT STUB-IN BOX

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT RUN, 3/4" MINIMUM U.O.N. RUN CONDUIT PER GENERAL NOTES

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text LOW VOLTAGE PLENUM CABLE RUN, OUT OF CONDUIT. CONDUIT STUBS TO ACCESSIBLE AREAS REQUIRED.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT FEED THRU, 1-1/4" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

SWITCH LEG

AutoCAD SHX Text

ISOLATED GROUND

AutoCAD SHX Text

HOT

AutoCAD SHX Text

NEUTRAL

AutoCAD SHX Text

HOME RUN, 3/4" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

HOME CONTINUATION, 3/4" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT RISER-DOWN, 1" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT RISER-UP, 1" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT EXISTING/EMPTY

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

CONDUIT STUB-OUT, 3/4" MINIMUM U.O.N.

AutoCAD SHX Text

PLANS/RISER

AutoCAD SHX Text

AV ELECTRICAL

AutoCAD SHX Text

AV ELECTRICAL

AutoCAD SHX Text

AV ELECTRICAL

AutoCAD SHX Text

AV ELECTRICAL

AutoCAD SHX Text

AutoCAD SHX Text

SHOWN FOR COORDINATION ONLY

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text TYPE 1G BOX = ONE GANG BOX EQUAL TO RACO 695 WITH SINGLE GANG PLASTER RING TYPE 1GS BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C ONE GANG PLASTER RING TYPE 2G BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C TWO GANG PLASTER RING TYPE 3G BOX = THREE GANG BOX EQUAL TO RACO 697 WITH 3 GANG PLASTER RING TYPE 4G BOX = FOUR GANG BOX EQUAL TO RACO 698 WITH 4 GANG PLASTER RING TYPE 5G BOX = FIVE GANG BOX EQUAL TO RACO 699 WITH 5 GANG PLASTER RING TYPE 6G BOX = SIX GANG BOX EQUAL TO RACO 965 WITH 6 GANG RACO 965 WITH 6 GANG PLASTER RING PLASTER RING LV DIVIDER = RACO 971 TYPE 1GW BOX = ONE GANG WEATHER BOX EQUAL TO CARLON E381D-CAR WITH CARLON E980 CN-CAR COVER CARLON E980 CN-CAR COVER

AutoCAD SHX Text

GANG BOX TYPES

AutoCAD SHX Text TYPE J6# JBOX = 6"x4"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J8# JBOX = 8"x8"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J10# JBOX = 10"x10"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J12# JBOX = 12"x12"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J16# JBOX = 16"x16"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J18# JBOX = 18"x18"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J24# JBOX = 16"x24"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER # INDICATES AN ALTERNATE DEPTH REQUIRED FOR THE JUNCTION BOX. UNSPECIFIED=4", 6 =6" DEEP, 8 = 8" DEEP

AutoCAD SHX Text

JUNCTION BOX TYPES

AutoCAD SHX Text

FLOOR BOX TYPES

AutoCAD SHX Text TYPE R1 RACK = MIDDLE ATLANTIC MRK-4426 OR EQUAL ON 3/4" PLYWOOD BASE PAINTED BLACK. GANG RACKS TOGETHER WHEN IN GROUPS, 24"Wx84"H EA.

AutoCAD SHX Text

RACK ENCLOSURE TYPES

AutoCAD SHX Text

CEILING LINE

AutoCAD SHX Text

FLOOR LINE

AutoCAD SHX Text

SURFACE MOUNTED

AutoCAD SHX Text

MOUNTED PROTRUDING

AutoCAD SHX Text

MOUNTED FLUSH

AutoCAD SHX Text

MOUNTED RECESS

AutoCAD SHX Text

FACE OF BOX

AutoCAD SHX Text

WP

AutoCAD SHX Text

WIRE TYPE CALL OUT LEGEND

AutoCAD SHX Text

TP

AutoCAD SHX Text

KP

AutoCAD SHX Text

AutoCAD SHX Text

AV-802

AutoCAD SHX Text

AutoCAD SHX Text

AV-802

AutoCAD SHX Text

MIC

AutoCAD SHX Text

OC

AutoCAD SHX Text

ANT

AutoCAD SHX Text

WAP

AutoCAD SHX Text

IR

AutoCAD SHX Text

ANT

AutoCAD SHX Text

WAP

AutoCAD SHX Text

1. ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE UNACCEPTABLE FOR OUR USE. 2. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. 3. ALL POWER WIRING IS BY E.C. ALL POWER WIRING IS BY E.C. 4. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. 5. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. 6. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. 7. ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

EXAMPLES OF AV SYMBOL BLOCKS

file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf AutoCAD SHX Text

WALL SIDE

file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf AutoCAD SHX Text

VARIOUS DISPLAY SIZES: TO SCALE W/WALL MOUNTS

AutoCAD SHX Text

WALL MOUNTED DISPLAY W/VTC CAMERA MOUNTED ABOVE

AutoCAD SHX Text

CEILING MOUNTED DISPLAY

AutoCAD SHX Text

AV EQUIPMENT RACK: TO SCALE

AutoCAD SHX Text

LECTERN

AutoCAD SHX Text

CONFERENCING SYSTEM MICROPHONE STATION

AutoCAD SHX Text

PAGING MICROPHONE

AutoCAD SHX Text

VIDEO CONFERENCING PTZ CAMERA

AutoCAD SHX Text

WALL MOUNTED 7" TOUCH PANEL

AutoCAD SHX Text

TABLE BOX: AV CONNECTIONS, POWER, LAN ETC.

AutoCAD SHX Text

SPKR

AutoCAD SHX Text

APROX COVERAGE OVER LAP

AutoCAD SHX Text

SPKR

AutoCAD SHX Text

HEADEND WIRE PULL

AutoCAD SHX Text

SPEAKER ZONE WIRING

AutoCAD SHX Text

LENS THROW MIN/MAX RANGE SHOWN HERE

AutoCAD SHX Text

FB TYPE 1 = POKE THRU TYPE 1 =

AutoCAD SHX Text

SPKR TYPE 1 = SPKR TYPE 2 = SPKR TYPE 3 =

AutoCAD SHX Text

SCREEN TYPE 1 = SCREEN TYPE 2 = LIFT TYPE 1 =

AutoCAD SHX Text

TP TYPE 1 =

AutoCAD SHX Text

JB

AutoCAD SHX Text

SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018

AutoCAD SHX Text

BUILDING PLAN LEGEND

AutoCAD SHX Text AV 45349.v-200

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

ORIGINAL DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

PM:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

AutoCAD SHX Text

SYSTEM ID

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

I3 FEDERAL

AutoCAD SHX Text

DEPT OF VA, SAN FRANCISCO CA

AutoCAD SHX Text 45349.v

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text Kate Eneria

AutoCAD SHX Text Daniel Urquiola

AutoCAD SHX Text Kirsi Ruotsala

AutoCAD SHX Text

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

UPDATED AUDIO COVERAGE

AutoCAD SHX Text

AutoCAD SHX Text 11/21/2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

FLOOR PLAN / RISER

FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322

DN

UP

DN

DN

DN

TO BLDG. 2

© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE

CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE

DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF

SOLUTIONZ, INC.

SOLUTIONZ, INC.

AutoCAD SHX Text

AUDITORIUM 112

AutoCAD SHX Text

RACK ROOM

AutoCAD SHX Text

SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018

AutoCAD SHX Text

AUDITORIUM 112

AutoCAD SHX Text

FLOOR PLAN

AutoCAD SHX Text AV 45349.v-201

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

ORIGINAL DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

PM:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

AutoCAD SHX Text

SYSTEM ID

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

I3 FEDERAL

AutoCAD SHX Text

DEPT OF VA, SAN FRANCISCO CA

AutoCAD SHX Text 45349.v

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text Kate Eneria

AutoCAD SHX Text Daniel Urquiola

AutoCAD SHX Text Kirsi Ruotsala

AutoCAD SHX Text

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

UPDATED AUDIO COVERAGE

AutoCAD SHX Text

AutoCAD SHX Text 11/21/2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

FLOOR PLAN / RISER

FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322

UP

DN

DN

DN

TO BLDG. 2

WP1

2-G BOX

80" AFF

WP2

2-G BOX

60" AFF

WP3

2-G BOX

42" AFF

FP1

2-G BOX

AV1

2-G BOX

18" AFF

© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE

CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE

DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF

SOLUTIONZ, INC.

SOLUTIONZ, INC.

AutoCAD SHX Text

FRONT WALL - VIDEO WALL

AutoCAD SHX Text

SIDE WALL - DISPLAY

AutoCAD SHX Text

LECTERN

AutoCAD SHX Text

TOUCH PANEL

AutoCAD SHX Text

AV RACK

AutoCAD SHX Text

SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018

AutoCAD SHX Text

AUDITORIUM 112

AutoCAD SHX Text

EQUIPMENT LAYOUT

AutoCAD SHX Text AV 45349.v-202

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

ORIGINAL DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

PM:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

AutoCAD SHX Text

SYSTEM ID

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

I3 FEDERAL

AutoCAD SHX Text

DEPT OF VA, SAN FRANCISCO CA

AutoCAD SHX Text 45349.v

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text Kate Eneria

AutoCAD SHX Text Daniel Urquiola

AutoCAD SHX Text Kirsi Ruotsala

AutoCAD SHX Text

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

UPDATED AUDIO COVERAGE

AutoCAD SHX Text

AutoCAD SHX Text 11/21/2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

FLOOR PLAN / RISER

FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322

FRONT WALL

LEAVE AN

EXCESS OF 15'

1-1/4" CONDUIT

FINISHED CEILING

FINISHED FLOOR

A-1 V-1 V-2

SPARE-WP1(4) CAT6/STP

WP1

2-G BOX

80" AFF

EQUIPMENT RACK

V-3

V-4(2) CAT6/STP

(5) CAT6/STP

C-1(1) CAT6/STP

FINISHED FLOOR

C-2 A-2 V-5

USB-1

SPARE-FP1

LEAVE AN

EXCESS OF 15'

1-1/4" CONDUITS

SPKR-16 SPKR-1

SPKR-16 SPKR-3

SPKR-16 SPKR-5

SPKR-16 SPKR-7

70V

CEILING SPEAKERS

(TYPICAL OF 2)

HOMERUN FIRST

SPEAKER

LEAVE AN

EXCESS OF 10'

SPKR-2SPKR-16

SIDE WALL

LEAVE AN

EXCESS OF 15'

1-1/4" CONDUIT

WP2

2-G BOX

60" AFF

TOUCH PANEL

LEAVE AN

EXCESS OF 5'

1-1/4" CONDUIT

WP2

2-G BOX

42" AFF

LECTERN

LEAVE AN

EXCESS OF 15'

1-1/4" CONDUIT

FP1

2-G BOX

LEAVE AN

EXCESS OF 10'

SPKR-4SPKR-16

LEAVE AN

EXCESS OF 10'

SPKR-6SPKR-16

LEAVE AN

EXCESS OF 10'

SPKR-8SPKR-16

AV1

2-G BOX

18" AFF

S1 S2

70V

CEILING SPEAKERS

(TYPICAL OF 2)

HOMERUN FIRST

SPEAKER

S3 S4

70V

CEILING SPEAKERS

(TYPICAL OF 2)

HOMERUN FIRST

SPEAKER

S5 S6

70V

CEILING SPEAKERS

(TYPICAL OF 2)

HOMERUN FIRST

SPEAKER

S7 S8

© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE

CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE

DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF

SOLUTIONZ, INC.

SOLUTIONZ, INC.

AutoCAD SHX Text

SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018

AutoCAD SHX Text

AUDITORIUM 112

AutoCAD SHX Text

RISER DIAGRAM

AutoCAD SHX Text AV 45349.v-501

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

ORIGINAL DATE

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

PM:

AutoCAD SHX Text

DATE

AutoCAD SHX Text

REV.

AutoCAD SHX Text

STATUS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

PROJECT

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS

AutoCAD SHX Text

SYSTEM ID

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

I3 FEDERAL

AutoCAD SHX Text

DEPT OF VA, SAN FRANCISCO CA

AutoCAD SHX Text 45349.v

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text Kate Eneria

AutoCAD SHX Text Daniel Urquiola

AutoCAD SHX Text Kirsi Ruotsala

AutoCAD SHX Text

AutoCAD SHX Text 08.30.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

AutoCAD SHX Text 10.03.2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

UPDATED AUDIO COVERAGE

AutoCAD SHX Text

AutoCAD SHX Text 11/21/2025

AutoCAD SHX Text

PRELIMINARY

AutoCAD SHX Text

FLOOR PLAN / RISER

FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322

Sheets and Views
AV 45349.v-100 Title Page - Drawing Index-AV-100
AV 45349.v-200 BuildingPlanLegend-AV-200
AV 45349.v-201 BuildingPlans-AV-201
AV 45349.v-201 BuildingPlans-AV-202
AV 45349.v-501 Riser-AV-501

File details come from the government source that posted it. Updated .