Dept of VA - San Francisco - Floor Plan_AV.pdf
PDF 1 MB Posted
- Attached to
- N059 - Audio/Visual System Upgrade, Building 7 Auditorium Room 112, VA San Francisco Health Care System
- Solicitation number
- 36C26126Q1096
About this file
This document is a set of architectural and systems drawings for an audiovisual (AV) installation at the U.S. Department of Veterans Affairs facility located at 4150 Clement Street, San Francisco, CA 94121, identified under Project Order #662-C24059.
The drawings provide detailed specifications for an auditorium AV system installation, including floor plans, equipment layouts, and infrastructure requirements. The design encompasses an Auditorium 112 with an associated rack room for equipment housing. Key components include multiple 70-volt ceiling speakers (S1-S8) distributed throughout the auditorium space, wall-mounted equipment boxes at various heights (WP1-WP3 for wall panels at 80", 60", and 42" above finished floor, FP1 for floor panel, and AV1 for equipment at 18" AFF), a lectern position with audio connectivity, and a front wall video display system. The system incorporates multiple conduit runs for audio and control signal distribution, with specified excess cable lengths for speaker homerun connections and equipment integration. System infrastructure includes wall-mounted touch panels for control, ceiling speaker mounting provisions, and equipment rack configuration in the dedicated rack room. The drawings employ standard AV industry symbols and legends to denote electrical connections, device types, conductor specifications, and mounting methodologies. Original drawings date to 08.30.2025 with revision 3 dated 11.21.2025, prepared by Solutionz, Inc.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26126Q1096.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U.S. Department Of Veterans Affairs 4150 Clement Street - San Francisco, CA 94121
PO# 662-C24059
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
ORIGINAL ISSUE DATE
AutoCAD SHX Text
REVISION LEVELL
AutoCAD SHX Text
LATEST REVISION ISSUE DATE
AutoCAD SHX Text
AV-100
AutoCAD SHX Text
TITLE PAGE - DRAWING INDEX
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-300
AutoCAD SHX Text
ONE LINE DRAWING LEGEND
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-301
AutoCAD SHX Text
AUDIO ONE LINE
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-401
AutoCAD SHX Text
VIDEO & CONTROL ONE LINE
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-900
AutoCAD SHX Text
TYP AV SYSTEM STANDARD PINOUT DETAILS
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-901
AutoCAD SHX Text
TYP AV SYSTEM STANDARD PINOUT DETAILS
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-902
AutoCAD SHX Text
PROJECT PIN OUT DETAILS
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
AV-903
AutoCAD SHX Text
PROJECT PIN OUT DETAILS
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
ORIGINAL ISSUE DATE
AutoCAD SHX Text
REVISION LEVELL
AutoCAD SHX Text
LATEST REVISION ISSUE DATE
AutoCAD SHX Text
AV-100
AutoCAD SHX Text
TITLE PAGE - DRAWING INDEX
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 11.21.2025
AutoCAD SHX Text
AV-200
AutoCAD SHX Text
BUILDING PLAN LEGEND
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 11.21.2025
AutoCAD SHX Text
AV-201
AutoCAD SHX Text
AUDITORIUM 112 - FLOOR PLAN
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 11.21.2025
AutoCAD SHX Text
AV-202
AutoCAD SHX Text
AUDITORIUM 112 - EQUIPMENT LAYOUT
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 11.21.2025
AutoCAD SHX Text
AV-501
AutoCAD SHX Text
RISER DIAGRAM
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
AutoCAD SHX Text 11.21.2025
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
ORIGINAL ISSUE DATE
AutoCAD SHX Text
REVISION LEVELL
AutoCAD SHX Text
LATEST REVISION ISSUE DATE
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text EACH DEVICE IN AN AV SYSTEM ARE GIVEN AN IDENTIFYING DEVICE TYPE ABBREVIATION AND NUMBER COUNTING THE QUANTITY OF THAT DEVICE WITHIN THAT SYSTEM. SEE AV-300 FOR THE DEVICE ABBREVIATION LEGEND. DEVICE ID'S ARE USED THROUGHOUT THE AV DRAWING SET.
AutoCAD SHX Text
DEVICE ID LEGEND
AutoCAD SHX Text
DDD-XXX
AutoCAD SHX Text
DEVICE QUANITY
AutoCAD SHX Text
DEVICE TYPE ABBREVIATION
AutoCAD SHX Text DEVICE ID'S AND CABLES IN AN AV SYSTEM ARE GIVEN A UNIQUE NUMBER PER SYSTEM. SELF-CONTAINED SYSTEMS THAT DO NOT TIE TO A MASTER ARE ONLY UNIQUE WITHIN THAT SUB-SYSTEM. BECAUSE OF THIS VARIOUS ROOMS (SYSTEMS) ON FLOOR PLANS AND RCP'S MAY HAVE SIMILAR DEVICE ID'S. THIS HELPS TRACKING AND UNDERSTANDING MULTIPLE SUB-SYSTEMS TO HAVE SIMILAR DEVICES AND ID'S HANDLED THE SAME IN EACH ROOM (SYSTEM).
AutoCAD SHX Text
NUMBERING SEQUENCE
AutoCAD SHX Text
DRAWING SERIES LEGEND
AutoCAD SHX Text
AV-000 TO AV-099
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
AV-100 TO AV-199
AutoCAD SHX Text
TITLE AND DRAWING INDEX
AutoCAD SHX Text
AV-200 TO AV-299
AutoCAD SHX Text
BUILDING PLANS, LAYOUTS, RISERS
AutoCAD SHX Text
AV-300 TO AV-399
AutoCAD SHX Text
SYSTEM ONE LINE DRAWINGS - NON COMPLEX A/V/C COMBINED
AutoCAD SHX Text
AV-300 TO AV-399
AutoCAD SHX Text
AUDIO ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-400 TO AV-499
AutoCAD SHX Text
VIDEO ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-500 TO AV-599
AutoCAD SHX Text
CONTROL ONE LINE DRAWINGS - COMPLEX
AutoCAD SHX Text
AV-600 TO AV-699
AutoCAD SHX Text
EQUIPMENT RACK, CABINET, CREDENZA ELEVATIONS
AutoCAD SHX Text
AV-700 TO AV-799
AutoCAD SHX Text
I/O PLATES, PANEL LAYOUTS, PATCHBAY LAYOUTS
AutoCAD SHX Text
AV-800 TO AV-899
AutoCAD SHX Text
MECHANICAL DETAILS, WALL/CEILING/FLOOR MOUNTING DETAILS
AutoCAD SHX Text
AV-900 TO AV-999
AutoCAD SHX Text
WIRING DIAGRAMS, PINOUT DETAILS, CUSTOM CABLING DETAILS
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
TITLE PAGE - DRAWING INDEX
AutoCAD SHX Text AV 45349.v-100
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
I3 FEDERAL
AutoCAD SHX Text
DEPT OF VA, SAN FRANCISCO CA
AutoCAD SHX Text 45349.v
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Daniel Urquiola
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
UPDATED AUDIO COVERAGE
AutoCAD SHX Text
AutoCAD SHX Text 11/21/2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
FLOOR PLAN / RISER
AutoCAD SHX Text FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
M O N I T O R
S I D E
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SPEAKER TYPES
AutoCAD SHX Text
SCREEN/LIFT TYPES
AutoCAD SHX Text
WALL TOUCH PNL TYPES
AutoCAD SHX Text
AV DEVICE OR BOX - WALL, CEILING, FLOOR
AutoCAD SHX Text
CABLE QTY/WIRE TYPE
AutoCAD SHX Text
CABLE ROUTING INFO
AutoCAD SHX Text
CONDUIT SIZE/NOTE
AutoCAD SHX Text Q
AutoCAD SHX Text T
AutoCAD SHX Text 3/4"
AutoCAD SHX Text
XX
AutoCAD SHX Text
AV BUILDING INFRASTRUCTURE SYMBOL LEGEND
AutoCAD SHX Text
WALL
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text JUNCTION BOX WITH COVER PLATE FOR AV CONNECTION. PROVIDED BY E.C. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT AT BUILDING STANDARD BASE ELECTRICAL HEIGHT UNLESS OTHERWISE INDICATED. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG. SEE GANG BOX TYPE LIST.
AutoCAD SHX Text JUNCTION BOX FOR A/V CONNECTIVITY. SEE JUNCTION BOX TYPES LIST AND WALL BOX MOUNTING METHODS.
AutoCAD SHX Text JUNCTION BOX FOR WALL/CEILING CAMERA LOCATIONS. MOUNT FLUSH WITH FINISHED WALL/CEILING TREATMENT. SUB-NUMBER INDICATES NUMBER OF GANG.
AutoCAD SHX Text
SPECIAL OUTLET
AutoCAD SHX Text
DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
POTS TELCO ANALOG PHONE LINE
AutoCAD SHX Text
POKE THRU LOCATION
AutoCAD SHX Text
DUPLEX OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
SINGLE WALL OUTLET, 3 PIN EDISON
AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
DEDICATED CIRCUIT
AutoCAD SHX Text
DEDICATED CIRCUIT WITH ISOLATED GROUND
AutoCAD SHX Text W
AutoCAD SHX Text
FB
AutoCAD SHX Text C
AutoCAD SHX Text
JB
AutoCAD SHX Text
CAM
AutoCAD SHX Text
CAM
AutoCAD SHX Text 20A
AutoCAD SHX Text 20A
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
IG
AutoCAD SHX Text D
AutoCAD SHX Text
D/IG
AutoCAD SHX Text
1. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. BOX MOUNTING HEIGHTS ARE TO CENTER OF FACE OF BOX. 2. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. BOX MOUNTING DEPTHS ARE TO FACE OF BOX. 3. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED U.O.N. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 4. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. VERIFY ALL STANDARD HEIGHTS WITH PREVAILING CONDITIONS AT JOBSITE. 5. THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH THESE DRAWINGS ARE FOR REQUIREMENTS REFERENCE ONLY. NOT FOR CONSTRUCTION. COORDINATE WITH ARCHITECT FOR ALL DEVICE LOCATIONS. 6. SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, SUPPLY AND INSTALLATION OF ALL CONDUIT, POWER CIRCUITS, BACK BOXES, ELECTRICAL DEVICES, ELECTRICAL WIRING IS TO BE PROVIDED BY THE PROJECT DIVISION 16 CONTRACTOR UNLESS NOTED OTHERWISE. 7. ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX ALL CONDUIT SHALL BE STEEL (EMT OR RIGID). ALUMINUM, FIBERGLASS, OR PVC NOT ACCEPTABLE. FLEX CONDUIT SHALL NOT BE CONSIDERED ACCEPTABLE. 8. E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT E.C. SHALL INSTALL NYLON ROPE IN ALL CONDUITS FOR WIRING SPECIFIED IN DIVISION 11. AND CONDUIT SHALL BE DE-BURRED, CLEANED, CAPPED. CONDUIT STUB-OUTS, JUNCTION BOXES, AND OUTLETS SHALL BE SUITABLY LABELED FOR IDENTIFICATION OF FUNCTION, J-BOX #, AND/OR CONDUIT NUMBER. 9. E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING E.C. TO PROVIDE BLANK COVER PLATES FOR ALL JUNCTION BOXES IF REQUIRED FOR BUILDING INSPECTIONS. 10. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 180º TOTAL OF BENDS. 11. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. E.C. SHALL INSTALL INTERMEDIATE PULL BOXES IN CONDUITS FOR EVERY 100 RUNNING FEET OF CONDUIT. 12. INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR INTERMEDIATE PULL BOXES SHALL BE 12"x12"x4", MINIMUM IF ANY CONDUIT ENTRY IS 1-1/4" OR LARGER. 13. INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" INTERMEDIATE PULL BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP IF ALL CONDUIT ENTRIES ARE 1" OR LESS. 14. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. ALL 120 VOLT WIRE, DEVICES, AND CONNECTIONS BY E.C. 15. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. ALL LOW VOLTAGE A/V SYSTEM DEVICES, AND CONNECTIONS BY A/V SYSTEM CONTRACTOR. 16. ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE ALL GANG-BOXES SHALL BE 3 1/2" DEEP, MINIMUM, SINGLE PIECE CONSTRUCTION. MODULAR BOXES ARE NOT ACCEPTABLE. ACCEPTABLE. 17. FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX FLUSH OR RECESS MOUNTED 1 & 2-GANG BOXES SHALL BE 4-11/16" SQUARE x 3 1/2" DEEP BOX WITH APPROPRIATE PLASTER RING EXTENSION U.O.N. 18. EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, EC TO PROVIDE ALL CONDUIT, J-BOXES, NEMA OR CUSTOM ENCLOSURES, FLOOR BOXES, POWER CIRCUITS, POWER WIRE AND POWER CONNECTIONS UNDER THIS SECTION. DEVICE PLATES AND CONNECTOR PANEL INFORMATION IS FOUND IN THE AV-700 SET OF DRAWINGS. 19. ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES ALL BOXES AND CONDUIT IN WALLS AND CEILINGS SHALL BE FLUSH MOUNTED OR CONCEALED. BOXES AND CONDUIT ON EXISTING WALLS AND CEILINGS MAY BE SURFACE MOUNTED UNLESS OTHERWISE NOTED. 20. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. SUPPORT ALL LOUDSPEAKER ENCLOSURES FROM STRUCTURE RATHER THAN FROM CEILING. 21. ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES ALL WIRING SHALL BE IN CONDUIT IN INACCESSIBLE AREAS UNLESS OTHERWISE NOTED. ALL DEVICES CONNECTED WITH MINIMUM 3/4"C. 22. REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH REFER TO ARCHITECTURAL ELEVATIONS AND CEILING PLANS FOR EXACT PLACEMENT OF FINISHES WITH DESIGN ARCHITECT. 23. FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING FLOOR PLANS ARE FINAL AUTHORITY OF DEVICE QUANTITIES WHICH ARE SUBJECT TO REVISION PROVIDING PROPER NOTICE. 24. WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR WHERE NO BACKBOX IS REQUIRED PLEASE REFERENCE THE MANUFACTURER'S INSTALLATION DETAIL FOR ROUGH-IN AND CONDUIT TERMINATION. 25. WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, WHERE EXACT DIMENSIONS ARE NOT CALLED OUT, THE LOCATION OF EQUIPMENT, JUNCTION BOXES, OUTLETS, WIRE WAYS, PANELS, ETC., ARE TO BE IDENTIFIED ON COORDINATION DRAWINGS FOR REVIEW ACCORDING TO PROJECT GENERAL CONDITIONS. 26. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. PROVIDE TEMPORARY LABELING DESCRIBING BOXES. 27. CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE CONCEAL CONDUIT CONNECTIONS TO JUNCTION BOXES MOUNTED IN PUBLIC AREAS. WHERE BOXES ARE SURFACE MOUNTED, CONDUIT SHALL ENTER FROM THE REAR OF THE BOX. 28. REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF REFER TO FLOOR PLANS AND CONDUIT RISER DIAGRAMS FOR CONDUIT SIZING AND INTERCONNECTION OF VARIOUS DEVICES. 29. CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE CONSTANT VOLTAGE LOUDSPEAKER CABLE SHALL BE ROUTED IN CONDUIT WHEN EXPOSED, INACCESSIBLE OR AS REQUIRED BY SITE CONDITIONS. 30. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. CONDUIT RUN IN SLABS SHALL HAVE A PULL BOX LOCATED FOR EACH 180 DEGREE BEND. 31. FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND FOR EVERY 100 FEET OF STRAIGHT EMPTY CONDUIT, THERE SHALL BE A MINIMUM OF ONE PULL BOX, AND AN ACCESSIBLE PULL BOX FOR MORE THAN TWO 90 DEGREE BENDS IN A CONDUIT RUN. 32. THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO THE DRAWINGS INDICATE ONE ROUTING METHOD FOR THE CONDUITS. MINOR CHANGES MAY BE MADE TO CONDUIT SYSTEM TO ACCOMMODATE SITE CONDITIONS OR SIMPLIFY INSTALLATION AS LONG AS ADEQUATE SIZING IS MAINTAINED AND THE SYSTEM INSTALLER AND ARCHITECT APPROVE THE COORDINATION DRAWINGS SUBMITTED FOR REVIEW. 33. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. E.C. TO PROVIDE CABLE PROTECTION BUSHINGS ON ALL BOXES AND CONDUIT STUB-OUTS. 35. POWER JUNCTION BOX. SURFACE MOUNT AT 96" A.F.F. PROVIDE 20A CIRCUITS WITH DEDICATED NEUTRALS AND OVERSIZED GROUND BACK TO PANEL "AV". LEAVE CIRCUIT TAIL AT 20' LENGTH FOR TERMINATION TO "AV", "TV", "ER" TYPE RACKS 36. MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH MOUNT DISPLAYS AT 60" O.C. A.F.F. UNLESS OTHERWISE NOTED. COORDINATE EXACT LOCATIONS AND MOUNTING WITH ARCHITECT. 37. PROJECTION SCREEN BACKBOX PROVIDED BY A/V AND INSTALLED BY GC. PROVIDE GANG BOX CONNECTIONS FOR LOW-VOLTAGE CONTROL AND MOTOR POWER FROM NEAREST POWER PANEL. SCREENS TO BE CONTROLLED BY A/V. 38. L/V CONTRACTOR TO PULL, TERMINATE, AND TEST ALL RISER AND DISTRIBUTION CABLING INCLUDING FIBER, AND NETWORK CATEGORY CABLES.
AutoCAD SHX Text -------CONTRACTORS------- A/V = PROJECT DIVISION 11 (SUB)CONTRACTOR. E.C. = PROJECT DIVISION 16 (SUB)CONTRACTOR. LVC = PROJECT LOW VOLTAGE (SUB) CONTRACTOR. -------MOUNTING LOCATION/ORIENTATION------- AFC = ABOVE FINISHED CEILING AFF = ABOVE FINISHED FLOOR B.C.P. = BLANK COVER PLATE BCS = BELOW COUNTER-TOP SURFACE BFC = BELOW FINISHED CEILING BFF = BELOW FINISHED FLOOR BOB = BOTTOM OF BOX COB = CENTER OF BOX SRH = PROJECT STANDARD RECEPTACLE HEIGHT SSH = PROJECT STANDARD SWITCH HEIGHT HT. = HEIGHT RU = RACK UNIT ( 1.75" HIGH x 19.25" WIDE ) -------STAGE/HOUSE DIRECTIONS------- BOH = BACK OF HOUSE BOH-L = BACK OF HOUSE LEFT BOH-R = BACK OF HOUSE RIGHT CS = CENTER STAGE (MID STAGE) DSC = DOWN STAGE CENTER DSL = DOWN STAGE LEFT DSR = DOWN STAGE RIGHT FOH = FRONT OF HOUSE FOH-L = FRONT OF HOUSE LEFT FOH-R = FRONT OF HOUSE RIGHT HC = HOUSE CENTER HL - HOUSE LEFT HR = HOUSE RIGHT SL = STAGE LEFT SR = STAGE RIGHT USC = UP STAGE CENTER USL = UP STAGE LEFT USR = UP STAGE RIGHT -------SIGNAL GROUPS------- A = AUDIO LEVEL SIGNAL V = VIDEO TYPE LEVEL SIGANAL C = CONTROL LEVEL SIGNAL H = HI RESOLUTION VIDEO SIGNAL F.O. = FIBER OPTIC RF = RADIO FREQUENCY SIGNAL -------TELECOMMUNICATIONS------- IDF = INTERMEDIATE DISTRIBUTION FACILITY IP = INTERNET PROTOCOL LAN = LARGE AREA NETWORK MDF = MAIN DISTRIBUTION FACILITY MDP= MATV DISTRIBUTION PROCESSOR VLAN = VIRTUAL LAN WAN = WIDE AREA NETWORK WAP = WIRELESS ACCESS POINT -------ELECTRICAL/POWER/RELAYS/SWITCHING------- e.c. EMPTY CONDUIT I.G. = ISOLATED GROUND (TECHNICAL GROUND) I.P. = ISOLATED POWER (BALANCED POWER) n.o. = NORMALLY OPEN CONTACT n.c. = NORMALLY CLOSED CONTACT -------DEVICE/INPUT/OUTPUT------- C.P. = COVER PLATE CH = CHANNEL COMB = COMBINER CSP = CONTROL SYSTEM PROCESSOR DSP - DIGITAL SIGNAL PROCESSOR DVP = DIGITAL VIDEO PLAYER ER = EQUIPMENT RACK ex. = EXISTING EQUIPMENT MOD = MODULATOR RX = RECEIVE SERV = SERVER TP = TOUCH PANEL TX - TRANSMIT VDP = VIDEO DISTRIBUTION PROCESSOR -------PROVISIONS--------- O.F.E. = OWNER FURNISHED EQUIPMENT O.F.O.I. = OWNER FURNISHED, OWNER INSTALLED O.F.C.I. = OWNER FURNISHED, CONTRACTOR INSTALLED C.F.O.I. = CONTRACTOR FURNISHED, OWNER INTALLED C.F.C.I. = CONTRACTOR FURNISHED, CONTRACTOR INSTALLED C.F.E.I = CONTRACTOR FURNISHED, ELECTRICAL INSTALLED E.F.E.I = ELECTRICAL FURNISHED, ELECTRICAL INSTALLED -------MISC------- AR = AS REQUIRED BY DOCUMENTS AS = AS SHOWN ON DRAWINGS CL = CENTER LINE IP = IPOD MB = MOUNTING BRACKET N.I.C. = NOT IN CONTRACT (FUTURE OR BY OTHERS) N/A = NOT APPLICABLE n/c = NO CONNECTION N/R = NOT REQUIRED N/U = NOT USED POE = POWER OVER ETHERNET QM = QUICK MEDIA RK = RACK KIT S.F. = STERILE FIELD T.B.D. = TO BE DETERMINED U.O.N. = UNLESS OTHERWISE NOTED
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
KEYED ELECTRICAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
AV SYSTEM DEVICE SYMBOL LEGEND
AutoCAD SHX Text
WALL
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text (WP=WALL PLATE, CP=CEILING PLATE, FP=FLOOR PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR AV CONNECTION. PROVIDED BY AVC. MOUNT FLUSH WITH FINISHED BOX OR LV RING. FLOOR JB ARE SUBJECT TO POKE-THRU AND FLOOR BOX INSERTS ETC. SUB-NUMBER INDICATES NUMBER OF GANG.
AutoCAD SHX Text (BP=BOX PLATE) JUNCTION BOX WITH CUSTOM PLATE FOR A/V CONNECTIVITY. CUSTOM PLATE IS DESIGNED WITH 1" ALL AROUND LARGER FLANGE TO COVER ROUGH OPENING AT JUNCTION BOX.
AutoCAD SHX Text CAMERA LOCATION. MOUNT MAY BE TO AN INSTALLED BOX OR MOUNTING PROVIDED WITH DISPLAY MOUNT OR MILLWORK.
AutoCAD SHX Text
SPECIAL OUTLET
AutoCAD SHX Text
DATA (BUILDING LAN) SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
TV CABLE. SUB-NUMBER INDICATES NUMBER OF DROPS REQUIRED.
AutoCAD SHX Text
POTS TELCO ANALOG PHONE LINE
AutoCAD SHX Text
WALL MOUNTED CONTROL TOUCH PANEL
AutoCAD SHX Text
WALL MOUNTED KEY PAD
AutoCAD SHX Text
POKE THRU PLATE
AutoCAD SHX Text
MICROPHONE LOCATION
AutoCAD SHX Text
OCCUPANCY SENSOR
AutoCAD SHX Text
ANTENNA
AutoCAD SHX Text
WIRELESS ACCESS POINT
AutoCAD SHX Text
INFRARED TRANSCEIVER
AutoCAD SHX Text
ELEVATION DETAIL CALL OUT. ARROW POINTS TO VIEWED DIRECTION ON DETAIL DRAWING.
AutoCAD SHX Text
DUPLEX OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
QUAD CEILING OUTLET, 3 PIN EDISON U.O.N.
AutoCAD SHX Text
SINGLE WALL OUTLET, 3 PIN EDISON
AutoCAD SHX Text SINGLE TWIST LOCK OUTLET w/RATING
AutoCAD SHX Text
REVISION NOTE
AutoCAD SHX Text
SHEET NOTE
AutoCAD SHX Text
WP
AutoCAD SHX Text
FP
AutoCAD SHX Text
CP
AutoCAD SHX Text
BP
AutoCAD SHX Text 20A
AutoCAD SHX Text 20A
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text P
AutoCAD SHX Text
JB
AutoCAD SHX Text
SCREEN CASE DRAWN TO SCALE
AutoCAD SHX Text
PROJECTOR SYMBOL NOT TO SCALE
AutoCAD SHX Text
PROJECTED LIGHT PATH
AutoCAD SHX Text
LENS CENTER LINE
AutoCAD SHX Text
CEILING MOUNTED
AutoCAD SHX Text
PROJECTOR/SCEEN
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
CEILING SPEAKER
AutoCAD SHX Text
APROX COVERAGE PATTERN 4' AFF
AutoCAD SHX Text 40°
AutoCAD SHX Text
APROX COVERAGE PATTERN
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
WALL MOUNTED SPEAKER
AutoCAD SHX Text
MOUNTING STYLES
AutoCAD SHX Text J-Box
AutoCAD SHX Text J-Box
AutoCAD SHX Text J-Box
AutoCAD SHX Text
HEIGHT AS SPECIFIED B.F.C.
AutoCAD SHX Text
JUNCTION BOX STYLES & ORIENTATIONS
AutoCAD SHX Text
HEIGHT AS SPECIFIED A.F.F.
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text J-Box
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
WALL
AutoCAD SHX Text C
AutoCAD SHX Text
DEVICE SYMBOL
AutoCAD SHX Text
CONDUCTOR TAGS AND CONDUIT SYMBOLS
AutoCAD SHX Text
FUNCTION
AutoCAD SHX Text
DRAWING REFERENCE
AutoCAD SHX Text
WALL BOX MOUNTING METHODS
AutoCAD SHX Text
SLAB BOX/CONDUIT STUB-IN BOX
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RUN, 3/4" MINIMUM U.O.N. RUN CONDUIT PER GENERAL NOTES
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text LOW VOLTAGE PLENUM CABLE RUN, OUT OF CONDUIT. CONDUIT STUBS TO ACCESSIBLE AREAS REQUIRED.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT FEED THRU, 1-1/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
SWITCH LEG
AutoCAD SHX Text
ISOLATED GROUND
AutoCAD SHX Text
HOT
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
HOME RUN, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
HOME CONTINUATION, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RISER-DOWN, 1" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT RISER-UP, 1" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT EXISTING/EMPTY
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
CONDUIT STUB-OUT, 3/4" MINIMUM U.O.N.
AutoCAD SHX Text
PLANS/RISER
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AV ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
SHOWN FOR COORDINATION ONLY
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text TYPE 1G BOX = ONE GANG BOX EQUAL TO RACO 695 WITH SINGLE GANG PLASTER RING TYPE 1GS BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C ONE GANG PLASTER RING TYPE 2G BOX = TWO GANG BOX EQUAL TO RACO 696 WITH 52-C TWO GANG PLASTER RING TYPE 3G BOX = THREE GANG BOX EQUAL TO RACO 697 WITH 3 GANG PLASTER RING TYPE 4G BOX = FOUR GANG BOX EQUAL TO RACO 698 WITH 4 GANG PLASTER RING TYPE 5G BOX = FIVE GANG BOX EQUAL TO RACO 699 WITH 5 GANG PLASTER RING TYPE 6G BOX = SIX GANG BOX EQUAL TO RACO 965 WITH 6 GANG RACO 965 WITH 6 GANG PLASTER RING PLASTER RING LV DIVIDER = RACO 971 TYPE 1GW BOX = ONE GANG WEATHER BOX EQUAL TO CARLON E381D-CAR WITH CARLON E980 CN-CAR COVER CARLON E980 CN-CAR COVER
AutoCAD SHX Text
GANG BOX TYPES
AutoCAD SHX Text TYPE J6# JBOX = 6"x4"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J8# JBOX = 8"x8"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J10# JBOX = 10"x10"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J12# JBOX = 12"x12"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J16# JBOX = 16"x16"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J18# JBOX = 18"x18"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER TYPE J24# JBOX = 16"x24"x4" NEMA TYPE 1 ENCLOSURE w/ SCREW COVER # INDICATES AN ALTERNATE DEPTH REQUIRED FOR THE JUNCTION BOX. UNSPECIFIED=4", 6 =6" DEEP, 8 = 8" DEEP
AutoCAD SHX Text
JUNCTION BOX TYPES
AutoCAD SHX Text
FLOOR BOX TYPES
AutoCAD SHX Text TYPE R1 RACK = MIDDLE ATLANTIC MRK-4426 OR EQUAL ON 3/4" PLYWOOD BASE PAINTED BLACK. GANG RACKS TOGETHER WHEN IN GROUPS, 24"Wx84"H EA.
AutoCAD SHX Text
RACK ENCLOSURE TYPES
AutoCAD SHX Text
CEILING LINE
AutoCAD SHX Text
FLOOR LINE
AutoCAD SHX Text
SURFACE MOUNTED
AutoCAD SHX Text
MOUNTED PROTRUDING
AutoCAD SHX Text
MOUNTED FLUSH
AutoCAD SHX Text
MOUNTED RECESS
AutoCAD SHX Text
FACE OF BOX
AutoCAD SHX Text
WP
AutoCAD SHX Text
WIRE TYPE CALL OUT LEGEND
AutoCAD SHX Text
TP
AutoCAD SHX Text
KP
AutoCAD SHX Text
AutoCAD SHX Text
AV-802
AutoCAD SHX Text
AutoCAD SHX Text
AV-802
AutoCAD SHX Text
MIC
AutoCAD SHX Text
OC
AutoCAD SHX Text
ANT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
IR
AutoCAD SHX Text
ANT
AutoCAD SHX Text
WAP
AutoCAD SHX Text
1. ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE ALL CONDUIT AND ELECTRICAL BOXES ARE TO BE BY E.C. UNLESS OTHERWISE SPECIFIED. GEM BOXES ARE UNACCEPTABLE FOR OUR USE. 2. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. ALL CONDUIT SHALL BE AT LEAST 3/4" DIAMETER UNLESS OTHERWISE SPECIFIED. 3. ALL POWER WIRING IS BY E.C. ALL POWER WIRING IS BY E.C. 4. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. AV CONDUIT DRAWING IS FOR THE AV SYSTEM ONLY. 5. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. A PULL STRING SHALL BE INSTALLED IN EACH CONDUIT BY THE E.C. FOR USE BY THE AVC. 6. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. ALL CONDUIT SHALL BE INSTALLED PER N.E.C. AND ANY APPLICABLE LOCAL CODES. 7. ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.ANY AC DESIGNATION IS FOR REFERENCE ONLY. REFER TO ELECTRICAL DRAWINGS FOR CIRCUIT REQUIREMENTS.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
EXAMPLES OF AV SYMBOL BLOCKS
file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-A.pdf AutoCAD SHX Text
WALL SIDE
file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///V:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/AV-LCD-K.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf file:///T:/CAD/BLOCK/Line%20Diagram/_Cut%20Sheets/A-MIC-L.pdf AutoCAD SHX Text
VARIOUS DISPLAY SIZES: TO SCALE W/WALL MOUNTS
AutoCAD SHX Text
WALL MOUNTED DISPLAY W/VTC CAMERA MOUNTED ABOVE
AutoCAD SHX Text
CEILING MOUNTED DISPLAY
AutoCAD SHX Text
AV EQUIPMENT RACK: TO SCALE
AutoCAD SHX Text
LECTERN
AutoCAD SHX Text
CONFERENCING SYSTEM MICROPHONE STATION
AutoCAD SHX Text
PAGING MICROPHONE
AutoCAD SHX Text
VIDEO CONFERENCING PTZ CAMERA
AutoCAD SHX Text
WALL MOUNTED 7" TOUCH PANEL
AutoCAD SHX Text
TABLE BOX: AV CONNECTIONS, POWER, LAN ETC.
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
APROX COVERAGE OVER LAP
AutoCAD SHX Text
SPKR
AutoCAD SHX Text
HEADEND WIRE PULL
AutoCAD SHX Text
SPEAKER ZONE WIRING
AutoCAD SHX Text
LENS THROW MIN/MAX RANGE SHOWN HERE
AutoCAD SHX Text
FB TYPE 1 = POKE THRU TYPE 1 =
AutoCAD SHX Text
SPKR TYPE 1 = SPKR TYPE 2 = SPKR TYPE 3 =
AutoCAD SHX Text
SCREEN TYPE 1 = SCREEN TYPE 2 = LIFT TYPE 1 =
AutoCAD SHX Text
TP TYPE 1 =
AutoCAD SHX Text
JB
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
BUILDING PLAN LEGEND
AutoCAD SHX Text AV 45349.v-200
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
I3 FEDERAL
AutoCAD SHX Text
DEPT OF VA, SAN FRANCISCO CA
AutoCAD SHX Text 45349.v
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Daniel Urquiola
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
UPDATED AUDIO COVERAGE
AutoCAD SHX Text
AutoCAD SHX Text 11/21/2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
FLOOR PLAN / RISER
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
DN
UP
DN
DN
DN
TO BLDG. 2
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
AUDITORIUM 112
AutoCAD SHX Text
RACK ROOM
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
AUDITORIUM 112
AutoCAD SHX Text
FLOOR PLAN
AutoCAD SHX Text AV 45349.v-201
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
I3 FEDERAL
AutoCAD SHX Text
DEPT OF VA, SAN FRANCISCO CA
AutoCAD SHX Text 45349.v
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Daniel Urquiola
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
UPDATED AUDIO COVERAGE
AutoCAD SHX Text
AutoCAD SHX Text 11/21/2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
FLOOR PLAN / RISER
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
UP
DN
DN
DN
TO BLDG. 2
WP1
2-G BOX
80" AFF
WP2
2-G BOX
60" AFF
WP3
2-G BOX
42" AFF
FP1
2-G BOX
AV1
2-G BOX
18" AFF
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
FRONT WALL - VIDEO WALL
AutoCAD SHX Text
SIDE WALL - DISPLAY
AutoCAD SHX Text
LECTERN
AutoCAD SHX Text
TOUCH PANEL
AutoCAD SHX Text
AV RACK
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
AUDITORIUM 112
AutoCAD SHX Text
EQUIPMENT LAYOUT
AutoCAD SHX Text AV 45349.v-202
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
I3 FEDERAL
AutoCAD SHX Text
DEPT OF VA, SAN FRANCISCO CA
AutoCAD SHX Text 45349.v
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Daniel Urquiola
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
UPDATED AUDIO COVERAGE
AutoCAD SHX Text
AutoCAD SHX Text 11/21/2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
FLOOR PLAN / RISER
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
FRONT WALL
LEAVE AN
EXCESS OF 15'
1-1/4" CONDUIT
FINISHED CEILING
FINISHED FLOOR
A-1 V-1 V-2
SPARE-WP1(4) CAT6/STP
WP1
2-G BOX
80" AFF
EQUIPMENT RACK
V-3
V-4(2) CAT6/STP
(5) CAT6/STP
C-1(1) CAT6/STP
FINISHED FLOOR
C-2 A-2 V-5
USB-1
SPARE-FP1
LEAVE AN
EXCESS OF 15'
1-1/4" CONDUITS
SPKR-16 SPKR-1
SPKR-16 SPKR-3
SPKR-16 SPKR-5
SPKR-16 SPKR-7
70V
CEILING SPEAKERS
(TYPICAL OF 2)
HOMERUN FIRST
SPEAKER
LEAVE AN
EXCESS OF 10'
SPKR-2SPKR-16
SIDE WALL
LEAVE AN
EXCESS OF 15'
1-1/4" CONDUIT
WP2
2-G BOX
60" AFF
TOUCH PANEL
LEAVE AN
EXCESS OF 5'
1-1/4" CONDUIT
WP2
2-G BOX
42" AFF
LECTERN
LEAVE AN
EXCESS OF 15'
1-1/4" CONDUIT
FP1
2-G BOX
LEAVE AN
EXCESS OF 10'
SPKR-4SPKR-16
LEAVE AN
EXCESS OF 10'
SPKR-6SPKR-16
LEAVE AN
EXCESS OF 10'
SPKR-8SPKR-16
AV1
2-G BOX
18" AFF
S1 S2
70V
CEILING SPEAKERS
(TYPICAL OF 2)
HOMERUN FIRST
SPEAKER
S3 S4
70V
CEILING SPEAKERS
(TYPICAL OF 2)
HOMERUN FIRST
SPEAKER
S5 S6
70V
CEILING SPEAKERS
(TYPICAL OF 2)
HOMERUN FIRST
SPEAKER
S7 S8
© 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
IT IS A VIOLATION OF LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF SOLUTIONZ, INC. TO ALTER OR COPY CONTENT IN THIS DOCUMENT IN ANY WAY. ANY LICENSEE WHO ALTERS THIS DOCUMENT IS REQUIRED BY LAW TO AFFIX HIS OR HER SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS OR HER SIGNATURE AND A SPECIFIC DESCRIPTION OF THE ALTERATIONS. THE
CONTENT OF THIS DOCUMENT IS THE PROPERTY OF SOLUTIONZ, INC. AND SHALL NOT BE
DUPLICATED, USED OR DISCLOSED--IN WHOLE OR IN PART-- WITHOUT WRITTEN PERMISSION OF
SOLUTIONZ, INC.
SOLUTIONZ, INC.
AutoCAD SHX Text
SEAGIDESIGNS@GMAIL.COM COPYRIGHT 2018
AutoCAD SHX Text
AUDITORIUM 112
AutoCAD SHX Text
RISER DIAGRAM
AutoCAD SHX Text AV 45349.v-501
AutoCAD SHX Text
PROJECT #
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
ORIGINAL DATE
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
PM:
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REV.
AutoCAD SHX Text
STATUS
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PROJECT
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text ALL RIGHTS RESEVERED SEAGIDESIGNS COPYRIGHT 2008 2020 DRAWING SYSTEM SEAGIDESIGNS
AutoCAD SHX Text
SYSTEM ID
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
I3 FEDERAL
AutoCAD SHX Text
DEPT OF VA, SAN FRANCISCO CA
AutoCAD SHX Text 45349.v
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text Kate Eneria
AutoCAD SHX Text Daniel Urquiola
AutoCAD SHX Text Kirsi Ruotsala
AutoCAD SHX Text
AutoCAD SHX Text 08.30.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
AutoCAD SHX Text 10.03.2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
UPDATED AUDIO COVERAGE
AutoCAD SHX Text
AutoCAD SHX Text 11/21/2025
AutoCAD SHX Text
PRELIMINARY
AutoCAD SHX Text
FLOOR PLAN / RISER
FAIRFAX OFFICE: 3975 FAIR RIDGE DRIVE SUITE 320 N FAIRFAX, VA 22033 Office: +1 (888) 815-6128 Support: +1 (888) 815-0322
| Sheets and Views |
| AV 45349.v-100 Title Page - Drawing Index-AV-100 |
| AV 45349.v-200 BuildingPlanLegend-AV-200 |
| AV 45349.v-201 BuildingPlans-AV-201 |
| AV 45349.v-201 BuildingPlans-AV-202 |
| AV 45349.v-501 Riser-AV-501 |