DEICER CLIN Structure and BEQ.xlsx
XLSX spreadsheet 19 KB Posted
- Attached to
- Presolicitation for DEICER Trucks Federal contract opportunity
- Solicitation number
- FA853421R0002
About this file
This document outlines the contract line item number (CLIN) structure and best estimated quantities (BEQ) for a federal contract to procure deicer trucks. The contract will have a basic 24-month period to allow time for the offeror to design, produce, and test first article units of two classes of deicer trucks. Class A units are truck mounted and reach 42 feet, with a minimum 1,600 gallon tank capacity. Class B units are extended reach and reach 75 feet, with a minimum 2,600 gallon tank capacity. Both classes have enclosed boom-mounted cabs. The contract will include four 12-month option periods after the basic period. The BEQ for Class A units is 34, and for Class B units is 23. A variety of CLINs are included for production units of each class, tropical rustproofing, finish colors, test equipment, familiarization videos, export packaging, and commissioning for CONUS and OCONUS locations. The contract also includes several CLINs for management and engineering documentation to be delivered on a non-separate price basis.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SOW-Deicers-2020_05_27.pdf | ||
| CID_A-A-59145D_20200608.pdf | ||
| CID_A-A-59145D_Revision_2020_07_10.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIN Structure and BEQ
| FA853421R0002 | |||||||
| CLIN | Nomenclature | SubCLIN Info | CLIN Type | BEQ | Supply / Service | ||
| 0001 | Preproduction Unit | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 0002 | Preproduction Unit | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 0003 | Production Unit | Class A Truck Mounted Deicer Trucks | FFP | 14 | Supply | ||
| 0004 | Production Unit | Class B Extended Reach Deicer Trucks | FFP | 7 | Supply | ||
| 0005 | Tropical Rustproofing | Class A Truck Mounted Deicer Trucks | FFP | 4 | Supply | ||
| 0006 | Tropical Rustproofing | Class B Extended Reach Deicer Trucks | FFP | 3 | Supply | ||
| 0007 | Finish Color | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 0008 | Finish Color | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 0009 | Special Test Equipment and Software | Class A Truck Mounted Deicer Trucks | FFP | 14 | Supply | ||
| 0010 | Special Test Equipment and Software | Class B Extended Reach Deicer Trucks | FFP | 7 | Supply | ||
| 0011 | Single Operator Drive System | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 0012 | Single Operator Drive System | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 0013 | Product Familiarization Video | Class A Truck Mounted Deicer Trucks | FFP | 6 | Supply | ||
| 0014 | Product Familiarization Video | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 0015 | Export Packaging | Class A Truck Mounted Deicer Trucks | FFP | 4 | Supply | ||
| 0016 | Export Packaging | Class B Extended Reach Deicer Trucks | FFP | 3 | Supply | ||
| 0017 | Commissioning - CONUS | CONUS | FFP | 4 | Supply | ||
| 0018 | Commissioning - OCONUS | OCONUS | FFP | 4 | Supply | ||
| 0019 | DI-MGMT-81928 (A001) Class A & Class B | Contractor's Progress, Status, & Management Report: Monthly Status Report | NSP | 1 | Supply | ||
| 0020 | DI-ADMN-81249B (A002) | Conference Agenda | NSP | 1 | Supply | ||
| 0021 | DI-ADMN-801250B (A003) | Conference Minutes | NSP | 1 | Supply | ||
| 0022 | DI-SAFT-81626 (A004) | System Safety Program Plan | NSP | 1 | Supply | ||
| 0023 | DI-SAFT-80101C (A005) | System Safety Hazard Analysis Report | NSP | 1 | Supply | ||
| 0024 | DI-NDTI-81307A (A006) | First Article Test Procedure | |||||
| First Article Qualification Test Plan and Procedures | NSP | 1 | Supply | ||||
| 0025 | DI-NDTI-80809B (A007) | Test/Inspection Report, First Article Test Report | NSP | 1 | Supply | ||
| 0026 | DI-CMAN-82019 (A008) | Product Base Line Index, Configuration Management and Control | NSP | 1 | Supply | ||
| 0027 | DI-SESS-80639E (A009) | Engineering Change Proposal | NSP | 1 | Supply | ||
| 0028 | DI-SESS-80642E (A010) | Notice of Revision (NOR) | NSP | 1 | Supply | ||
| 0029 | DI-SESS-80640E (A011) | Request for Variance | NSP | 1 | Supply | ||
| 0030 | DI-MISC-81618 (A012) | Service Bulletins/Technical Review Data Package | NSP | 1 | Supply | ||
| 0031 | DI-AVCS-80700 (A013) | Computer Software Product End Items | NSP | 1 | Supply | ||
| 0032 | DI-MISC-81454D (A014) | Computer Program Identification Number Catalog Information | NSP | 1 | Supply | ||
| 0033 | DI-IPSC-82249 (A015) | Software Assurance Evaluation Report | NSP | 1 | Supply | ||
| 0034 | TMCR 86-01 (TM 86-01) | Technical Manual Contract Requirements | NSP | 1 | Supply | ||
| 1001 | Production Unit | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 1002 | Production Unit | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 1003 | Tropical Rustproofing | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 1004 | Tropical Rustproofing | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 1005 | Finish Color | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 1006 | Finish Color | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 1007 | Special Test Equipment and Software | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 1008 | Special Test Equipment and Software | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 1009 | Single Operator Drive System | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 1010 | Single Operator Drive System | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 1011 | Product Familiarization Video | Class A Truck Mounted Deicer Trucks | FFP | 3 | Supply | ||
| 1012 | Product Familiarization Video | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 1013 | Export Packaging | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 1014 | Export Packaging | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 1015 | Commissioning - CONUS | CONUS | FFP | 4 | Supply | ||
| 1016 | Commissioning - OCONUS | OCONUS | FFP | 4 | Supply | ||
| 1017 | DI-MGT-80227 (A001) | Contractor's Progress, Status, & Management Report: Monthly Status Report | NSP | 1 | Supply | ||
| 1018 | DI-CMAN-81218 (A008) | Product Base Line Index, Configuration Management and Control | NSP | 1 | Supply | ||
| 1019 | DI-SESS-80639D (A009) | Engineering Change Proposal | NSP | 1 | Supply | ||
| 1020 | DI-SESS-80642D (A010) | Notice of Revision | NSP | 1 | Supply | ||
| 1021 | DI-SESS-80640D (A011) | Request for Variance | NSP | 1 | Supply | ||
| 1022 | DI-MISC-81618 (A012) | Service Bulletins | NSP | 1 | Supply | ||
| 1023 | TMCR 86-01 | Technical Manual Contract Requirements | NSP | 1 | Supply | ||
| 2001 | Production Unit | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 2002 | Production Unit | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 2003 | Tropical Rustproofing | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 2004 | Tropical Rustproofing | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 2005 | Finish Color | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 2006 | Finish Color | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 2007 | Special Test Equipment and Software | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 2008 | Special Test Equipment and Software | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 2009 | Single Operator Drive System | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 2010 | Single Operator Drive System | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 2011 | Product Familiarization Video | Class A Truck Mounted Deicer Trucks | FFP | 3 | Supply | ||
| 2012 | Product Familiarization Video | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 2013 | Export Packaging | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 2014 | Export Packaging | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 2015 | Commissioning - CONUS | CONUS | FFP | 4 | Supply | ||
| 2016 | Commissioning - OCONUS | OCONUS | FFP | 4 | Supply | ||
| 2017 | DI-MGT-80227 | Contractor's Progress, Status, & Management Report: Monthly Status Report | NSP | 1 | Supply | ||
| 2018 | DI-CMAN-81218 | Product Base Line Index, Configuration Management and Control | NSP | 1 | Supply | ||
| 2019 | DI-SESS-80639D | Engineering Change Proposal | NSP | 1 | Supply | ||
| 2020 | DI-SESS-80642D | Notice of Revision | NSP | 1 | Supply | ||
| 2021 | DI-SESS-80640D | Request for Variance | NSP | 1 | Supply | ||
| 2022 | DI-MISC-81618 | Service Bulletins | NSP | 1 | Supply | ||
| 2023 | TMCR 86-01 | Technical Manual Contract Requirements | NSP | 1 | Supply | ||
| 3001 | Production Unit | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 3002 | Production Unit | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 3003 | Tropical Rustproofing | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 3004 | Tropical Rustproofing | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 3005 | Finish Color | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 3006 | Finish Color | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 3007 | Special Test Equipment and Software | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 3008 | Special Test Equipment and Software | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 3009 | Single Operator Drive System | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 3010 | Single Operator Drive System | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 3011 | Product Familiarization Video | Class A Truck Mounted Deicer Trucks | FFP | 3 | Supply | ||
| 3012 | Product Familiarization Video | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 3013 | Export Packaging | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 3014 | Export Packaging | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 3015 | Commissioning - CONUS | CONUS | FFP | 4 | Supply | ||
| 3016 | Commissioning - OCONUS | OCONUS | FFP | 4 | Supply | ||
| 3017 | DI-MGT-80227 | Contractor's Progress, Status, & Management Report: Monthly Status Report | NSP | 1 | Supply | ||
| 3018 | DI-CMAN-81218 | Product Base Line Index, Configuration Management and Control | NSP | 1 | Supply | ||
| 3019 | DI-SESS-80639D | Engineering Change Proposal | NSP | 1 | Supply | ||
| 3020 | DI-SESS-80642D | Notice of Revision | NSP | 1 | Supply | ||
| 3021 | DI-SESS-80640D | Request for Variance | NSP | 1 | Supply | ||
| 3022 | DI-MISC-81618 | Service Bulletins | NSP | 1 | Supply | ||
| 3023 | TMCR 86-01 | Technical Manual Contract Requirements | NSP | 1 | Supply | ||
| 4001 | Production Unit | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 4002 | Production Unit | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 4003 | Tropical Rustproofing | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 4004 | Tropical Rustproofing | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 4005 | Finish Color | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 4006 | Finish Color | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 4007 | Special Test Equipment and Software | Class A Truck Mounted Deicer Trucks | FFP | 5 | Supply | ||
| 4008 | Special Test Equipment and Software | Class B Extended Reach Deicer Trucks | FFP | 4 | Supply | ||
| 4009 | Single Operator Drive System | Class A Truck Mounted Deicer Trucks | FFP | 1 | Supply | ||
| 4010 | Single Operator Drive System | Class B Extended Reach Deicer Trucks | FFP | 1 | Supply | ||
| 4011 | Product Familiarization Video | Class A Truck Mounted Deicer Trucks | FFP | 3 | Supply | ||
| 4012 | Product Familiarization Video | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 4013 | Export Packaging | Class A Truck Mounted Deicer Trucks | FFP | 2 | Supply | ||
| 4014 | Export Packaging | Class B Extended Reach Deicer Trucks | FFP | 2 | Supply | ||
| 4015 | Commissioning - CONUS | CONUS | FFP | 4 | Supply | ||
| 4016 | Commissioning - OCONUS | OCONUS | FFP | 4 | Supply | ||
| 4017 | DI-MGT-80227 | Contractor's Progress, Status, & Management Report: Monthly Status Report | NSP | 1 | Supply | ||
| 4018 | DI-CMAN-81218 | Product Base Line Index, Configuration Management and Control | NSP | 1 | Supply | ||
| 4019 | DI-SESS-80639D | Engineering Change Proposal | NSP | 1 | Supply | ||
| 4020 | DI-SESS-80642D | Notice of Revision | NSP | 1 | Supply | ||
| 4021 | DI-SESS-80640D | Request for Variance | NSP | 1 | Supply | ||
| 4022 | DI-MISC-81618 | Service Bulletins | NSP | 1 | Supply | ||
| 4023 | TMCR 86-01 | Technical Manual Contract Requirements | NSP | 1 | Supply |
File details come from the government source that posted it. Updated .