Dearborn Training Center - Drawing BID.pdf
PDF 8 MB Posted
- Solicitation number
- RFP-091525- Fire Training & Emergency Center Facility Renova
- Issued by
- Wayne County, Michigan
About this file
These documents are architectural, mechanical, electrical, and plumbing (AMEP) design plans for the Dearborn Fire Department Training & Emergency Management Facility located at 2661 Greenfield Road in Dearborn, Michigan. The project involves a comprehensive renovation of an existing facility, with design work completed by DiClemente Siegel Design Inc. The plans detail a full architectural redesign of a first-floor space, including demolition of existing systems and installation of new mechanical, electrical, plumbing, and architectural elements across multiple rooms such as offices, locker rooms, a lobby, classrooms, and support spaces.
The project includes the installation of new rooftop HVAC units (RTU-1, RTU-2, RTU-3), exhaust fans, electrical panels, lighting systems, and plumbing infrastructure. The design emphasizes accessibility, with detailed specifications for ADA-compliant fixtures and mounting heights. The electrical plans show new power distribution, lighting controls with occupancy sensors, and a comprehensive approach to emergency and standard power systems. The mechanical plans outline HVAC zoning, ventilation strategies, and equipment specifications. The overall design appears to be a modern, functional renovation focused on creating an efficient training and emergency management facility for the Dearborn Fire Department, with careful attention to code compliance, system integration, and functional workspace design.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET:
ACADFILE:
ISSUED FOR:
DATE:
ENGINEERING AND ARCHITECTURE
DEARBORN, MI 48120
DSD PROJECT No. 24-1312
28105 GREENFIELD ROAD
DiCLEMENTE SIEGEL DESIGN INC.
SOUTHFIELD, MICHIGAN 48076-3046
TRAINING & EMERGENCY MANAGEMENT FACILITY
DEARBORN FIRE DEPARTMENT
2661 GREENFIELD RD.
LOCATION MAP
241312-G-001
G-001
NOT TO SCALE
BID
07/29/2025
N
WOMEN'S
LOCKER ROOM
MEN'S LOCKER
ROOM
MECHANICAL
EOC/CLASSROOM
ARCHIVES
(FUTURE)
OPEN OFFICE
EMERGENCY
MANAGER
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
TOILET ROOM
OFFICE
OFFICE
OFFICE
LOBBY
ROUGE RIVER
G R
E E
N F
IE
L D
R D
ELECTRICAL SHEET INDEX
SHEET DESCRIPTION
E-001 ELECTRICAL GENERAL INFORMATION
ED101 ELECTRICAL FIRST FLOOR DEMOLITION PLAN
EL101 FIRST FLOOR LIGHITNG PLAN
EL601 DIAGRAMS
EP101 FIRST FLOOR POWER PLAN
EP601 ONE LINE DIAGRAM AND PANELSCHEDULES
MECHANICAL SHEET INDEX
SHEET DESCRIPTION
M-001 MECHANICAL GENERAL INFORMATION
P-101 FIRST FLOOR PLUMBING PLANS
M-101 FIRST FLOOR MECHANICAL PLANS
M-500 MECHANICAL DETAILS AND SCHEDULES
ARCHITECTURAL SHEET INDEX
SHEET DESCRIPTION
A-001 GENERAL PROJECT INFORMATION
A-002 GENERAL PROJECT INFORMATION
A-003 CODE SUMMARY
AD111 FIRST FLOOR DEMOLITION PLANS
A-101 FIRST FLOOR ARCHITECTURAL PLAN
A-111 FIRST FLOOR FINISH PLAN
A-141 FIRST FLOOR REFLECTED CEILING PLAN
A-151 ARCHITECTURAL ROOF PLAN
A-301 MILLWORK SECTIONS
A-401 ENLARGED ARCHITECTURAL PLANS
A-410 INTERIOR ELEVATIONS
A-501 ARCHITECTURAL DETAILS
A-601 DOOR AND FRAME SCHEDULE
A-602 FINISH SCHEDULES
A-603 WALL SCHEDULE
G-001 COVER SHEET
BJR
Rectangle
AE1-01-01
DETAIL LOCATION IDENTIFICATION
ELEVATION INDICATION - (FLOORS, ETC...)
WINDOW NUMBER INDICATION
DOOR NUMBER INDICATION
TITLE IDENTIFICATION
SECTION LOCATION IDENTIFICATION
PLAN IDENTIFICATION
ELEVATION LOCATION IDENTIFICATION
ROOM NAME AND NUMBER INDICATION
COLUMN INDICATION
MATERIAL OR WORK DIVISION INDICATION
MATCH LINE INDICATION
ROOF OR RAMP PITCH INDICATION
ROOF OR RAMP SLOPE INDICATION
REVISION INDICATION
REFERENCE SYMBOLS
MATCH LINE - SEE SHEET AE1-01-01
EXISTING NEW
ELEVATION IDENTIFICATION
NUMBER(S) INDICATES
DIRECTION OF VIEW OR VIEWS
(SAME NUMBER ON SHEET
WHERE DRAWN)
SHEET IDENTIFICATION NUMBER
(INDICATES SHEET NUMBER
WHERE ELEVATION IS DRAWN)
KEYED NOTE SYMBOLS
1 GENERAL NOTE
DEMOLITION WORK
NEW WORK
FUTURE WORK
BUILDING SECTION
WALL SECTION
DETAIL SECTION
AE1-01-01
WALL TAG
PARTITION TYPE INDICATION
0 1' 2' 1"=1'-0"
0'-0"
SPOT ELEVATION
GRAPHIC SCALE
(0000)
FINISHED FLOOR
0'-0" (0000)
AE1-01-01
3.1
A
SLOPE
AE1-01-01
SIM
AE1-01-01
AE1-01-01
AE1-01-01
ROOM IDENTIFICATION NUMBER
COLUMN IDENTIFICATION LETTER OR
NUMBER FOR EXISTING CONSTRUCTION
COLUMN IDENTIFICATION LETTER OR
NUMBER FOR NEW CONSTRUCTION
PLAN OR SECTION DETAIL
IDENTIFICATION NUMBER
(SAME NUMBER ON SHEET
WHERE DRAWN)
SHEET IDENTIFICATION
NUMBER (INDICATES
SHEET NUMBER WHERE
PLAN OR SECTION DETAIL
IS DRAWN)
SHEET IDENTIFICATION NUMBER
(INDICATES SHEET NUMBER
WHERE DETAIL IS TYPICALLY
REFERENCED - NOT ALL
INCLUSIVE)
SECTION IDENTIFICATION NUMBER
(SAME NUMBER ON SHEET WHERE
REFERENCED)
SECTION IDENTIFICATION NUMBER
(SAME NUMBER ON SHEET WHERE
DRAWN)
SHEET IDENTIFICATION NUMBER
(INDICATES SHEET NUMBER
WHERE SECTION IS DRAWN)
W101A W101A
L101A L101A
A.F.F.
CEILING TYPE
HEIGHT
Rm. No. Room Name
Use Group Area Occupancy
101 NAME
150 SF LOADTYPE
MAX
150 SF
# P
LOUVER NUMBER INDICATION
CEILING TAG
LIFE SAFETY SYMBOLS
OCCUPANCY TAG OPTION 1
OCCUPANCY DOOR EXIT
OCCUPANCY TAG OPTION 2
AREA NAME
150 SF
AREA NAME AND NUMBER
INDICATION
FLOOR FINISH TAG
CASEWORK TAG
CW-01
PLUMBING ACCESSORY TAG
PLUMBING FIXTURE TAG
PF-01
CT-1
PF-01
SCALE:
A-001 1/8" = 1'-0"
VIEW TITLEVIEW TITLE
CW-01
TA-01TA-01
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-001
GENERAL PROJECT
INFORMATION
B. REED
& AND
@ AT
A ANGLE
A/C AIR CONDITIONER / CONDITIONING
ABV ABOVE
ACCS ACCESSORIES
ACSDR ACCESS DOOR
ACSFLR ACCESS FLOOR
ACST /
ACOUS
ACOUSTICAL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADDL ADDITIONAL
ADDM ADDENDUM
ADJ ADJUSTABLE / ADJACENT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHR ANCHOR
AHU AIR HANDLING UNIT
AL /
ALUM
ALUMINUM
ALNMT ALIGNMENT
ALT ALTERNATE
ANOD ANODIZED
AP ACCESS PANEL
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATELY
APPVD APPROVED
ARCH ARCHITECT(URAL)
ASPH ASPHALT
ASTM AMERICAN SOCIETY FOR TESTING MATERIALS
AUTO AUTOMATIC
AVG AVERAGE
BD BOARD
BET BETWEEN
BG BUMPER GUARD
BITUM BITUMINOUS
BL BLACK
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BMS BALANCE MAGNETIC SWITCH
BOS BOTTOM OF STEEL
BOT BOTTOM
BS BOTH SIDES
CAB CABINET
CAS CASEWORK
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CF CUBIC FOOT
CG CORNER GUARD
CH CEILING HEIGHT
CHAM CHAMFER
CHBD CHALKBOARD
CI CAST IRON
CI CONTRACTOR INSTALLED
CIP CAST IN PLACE
CJ CONTROL JOINT
CL CENTER LINE
ABBREVIATIONS
CLG CEILING
CLO CLOSET
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN/CLEAR OUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CORR CORRIDOR
CPR COPPER
CPT CARPET(ED)(ING)
CT CERAMIC TILE
CTR COUNTER
DBL DOUBLE
DEFS DIRECT APPLIED EXTERIOR FINISH SYSTEM
DEG DEGREE
DEMO DEMOLISH
DEP DEPRESSION
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DIV DIVISION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
E EAST
EA EACH
EF EACH FREE
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSED / ENCLOSURE
ENG ENGINEER
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL(LY)
EQPT EQUIPMENT
EST ESTIMATE
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FIRE ALARM
FAST FASTEN(ER)
FCO FLOOR CLEAN OUT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FEC (R) FIRE EXTINGUISHER CABINET, RECESSED
FEC (SR) FIRE EXTINGUISHER CABINET, SEMI-RECESSED
FEW FIRE EXTINGUISHER, WALL MOUNTED
FF FINISHED FLOOR
FGL FIBERGLASS
FIN FINISH(ED)
FIXT FIXTURE
FL FLOOR
FLASH FLASH(ING)
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUDS
FOW FACE OF WALL
FP FIREPROOF
FPL FIREPLACE
FR FRAME
FRC FIBER REINFORCED CONCRETE
FRGP FIBER REINFORCED GYPSUM PLASTER
FRT FIRE RETARDANT TREATED
FS FLOOR SINK
FTG FOOTING
FURR FURRING
FUT FUTURE
GA GAUGE
GALV GALVANIZE(D)
GB GRAB BAR
GC GENERAL CONTRACTOR
GL GLASS / GLAZING
GND GROUND
GR GRADE
GRV GRAVEL
GT GLASS TILE
GYP GYPSUM
GYP BD GYPSUM BOARD
HB HOSE BIB
HC HOLLOW CORE
HCP HANDICAPPED
HD HEAVY DUTY
HD HARD
HDR HEADER
HDWR HARDWARE
HI HIGH
HM HOLLOW METAL
HMI HOLLOW METAL INSULATED
HOR /
HORIZ
HORIZONTAL
HP HIGH POINT
HR HANDRAIL
HR HOUR
HT HEIGHT
HVAC HEATING / VENTILATION / AIR CONDITIONING
HW HARDWARE
HYD HYDRANT
ID INSIDE DIAMETER
IN INCH / INCHES
INCL INCLUDE(D) / INCLUDING
INSUL INSULATE / INSULATION
INT INTERIOR
JAN JANITOR
JT JOINT
KIT KITCHEN
LAB LABORATORY
LAM LAMINATE(D)
LAV LAVATORY
LB(S) POUND(S)
LF LINEAR FOOT (FEET)
LH LEFT HAND
LIB LIBRARY
LKR LOCKER
LNS LINOLEUM SHEET
LNT LINOLEUM TILE
LP LOW POINT
LT LIGHT
LVR LOUVER
LWT LIGHT WEIGHT
MACH MACHINE
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MC MEDICINE CABINET
ME MECHANICAL EQUIPMENT
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURE(R)
MH MANHOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MLD /
MLDG
MOULDING
MO MASONRY OPENING
MR MOISTURE RESISTANT
MTD MOUNTED
MTL METAL
MUL MULLION
N NORTH
NA OR
N/A
NOT AVAILABLE / APPLICABLE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NO / # NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OBS OBSCURE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFF OFFICE
OPG /
OPNG
OPENING
OPP OPPOSITE
OZ OUNCE
PART PARTIAL
PAT PATTERN
PBD PARTICLE BOARD
PC / PCC PRECAST CONCRETE
PED PEDESTAL
PER PERIMETER
PERF PERFORATED
PERP PERPENDICULAR
PF PRE-FINISHED
PIP POURED-IN-PLACE
PL PROPERTY LINE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLYWD PLYWOOD
PMF PRESSED METAL FRAMES
POP POINT OF PRESENCE
PR PAIR
PRCST PRE-CAST
PREFAB PREFABRICATED
PROP PROPERTY
PRT PORCELAIN TILE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT
PTD PAPER TOWEL DISPENSER
PTD/WR PAPER TOWEL DISPENSER &WASTE
RECEPTACLE
PTDF PRESSURE TREATED DOUGLAS FIR
PTN PARTITION
PTR PAPER TOWEL RECEPTACLE
PVC POLYVINYL CHLORIDE
Q QUARTZ
QT QUARRY TILE
QTY QUANTITY
R RISER
RAD RADIUS
RB RUBBER BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE(D)
REQ REQUIRED
RESIL RESILIENT
RESS RESILIENT SHEET
REST RESILIENT TILE
RET RETAINING
REV REVISE / REVISION
RFG ROOFING
RFL REFLECTED
RH RIGHT HAND
RM ROOM
RO ROUGH OPENING
RS RUBBER SHEET FLOORING
RST RUBBER STAIR TREADS
RSTR RUBBER STAIR TREADS & RISERS
RT RUBBER TILE
RWD REDWOOD
RWL RAIN WATER LEADER
S SOUTH
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCHED SCHEDULE
SCN SCREEN
SCR SCREEN
SD SOAP DISPENSER / STORM DRAIN
SDC SEALED CONCRETE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SHTG SHEATHING
SHWR SHOWER
SIM SIMILAR
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SOG SLAB ON GRADE
SPEC SPECIFY / SPECIFICATION
SPK SPEAKER
SQ SQUARE
SQFT SQUARE FEET
SQIN SQUARE INCH(ES)
SS STAINLESS STEEL
ST STONE
STA STATION
STC STAINED CONCRETE
STD STANDARD
STDS STUDS
STIFF STIFFENER
STL STEEL
STN STAINED
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SYM SYMMETRICAL
SYN SYNTHETIC
SYS SYSTEM
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR
TBD TO BE DETERMINED
TC TOP OF CURB
TEL TELEPHONE
TEMP TEMPORARY / TEMPERATURE
TER TERRAZZO
THK THICK
THRU THROUGH
TOC TOP OF CONCRETE
TOS TOP OF SLAB
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TV TELEVISION
TYP TYPICAL
UC UNDERCUT
UG UNDERGROUND
UL UNDERWRITER'S LABORATORY
UNF /
UNFIN
UNFINISHED
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTIBLE POWER SUPPLY
UR URINAL
V VOLT
VAC VACUUM
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VENT VENTILATE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VNR VENEER
VOL VOLUME
VST VINYL STAIR TREADS
VSTR VINTYL STAIR TREADS & RISERS
VT VINYL TILE
VTR VENT THRU ROOF
VWC VINYL WALLCOVERING
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCV WALLCOVERING
WD WOOD
WF WIDE FLANGE
WG WIRE GLASS
WH WALL HOSE / HYDRANT
WI WROUGHT IRON
WIN WINDOW
WK WORK
WNSCT WAINSCOT
WP WATERPROOF(ING)
WPT WORK POINT
WR WATER RESISTANT
WRR WOOD RISER
WT WEIGHT
YD YARD
ARCHITECTURAL:
THIS OVERVIEW OF SCOPE IS INCLUDED TO GIVE THE CONTRACTOR A
GENERAL OVERVIEW OF THE PROJECT REQUIREMENTS. THE OVERVIEW IS
NOT ALL INCLUSIVE AND IS NOT INTENDED TO, AND SHOULD NOT BE USED
TO, ESTABLISH CONTRACT LIMITS OR PRICING INCLUSIONS. THE CONTRACT
DOCUMENTS SHALL BE USED TO ESTABLISH CONSTRUCTION CONTRACT
SCOPE.
THIS OVERVIEW OF SCOPE INCLUDES, BUT IS NOT LIMITED TO THE...
OVERVIEW OF ARCHITECTURAL SCOPE
PROJECT REQUIREMENTS
PROVIDE ALL NECESSARY PERMITS. ALL WORK SHALL BE INSTALLED TO COMPLY
WITH THE OWNER'S STANDARDS, STATE AND LOCAL CODES INCLUDING, BUT NOT
LIMITED TO, THE FOLLOWING CODES AND THEIR RELATED REFERENCES.
2021 MICHIGAN BUILDING CODE
2021 MICHIGAN MECHANICAL CODE
2021 MICHIGAN PLUMBING CODE
2021 INTERNATIONAL FIRE CODE (AS REFERENCED)
2021 INTERNATIONAL FUEL GAS CODE
NFPA 101 LIFE SAFETY CODE 2012 (AS REFERENCED)
2021 MICHIGAN ENERGY CODE
2023 NATIONAL ELECTRICAL CODE AS AMENDED BY THE MICHIGAN CONSTRUCTION
CODE PART 8, ELECTRICAL CODE RULES.
2013 NFPA 110 AND NFPA 111
MANUFACTURER AND MODEL NUMBER LISTED REPRESENTS THE BASIS OF DESIGN
FOR THIS PROJECT. THE CONTRACTOR SHALL BEAR ALL ADDITIONAL COSTS
ASSOCIATED WITH USING EQUIPMENT AND/OR SYSTEMS BY OTHER APPROVED
MANUFACTURERS INCLUDING ADDITIONAL COSTS BY OTHER TRADES.
ALL EQUIPMENT AND/OR SYSTEMS INSTALLED SHALL BE IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. WHERE FIELD OR PROJECT CONDITIONS
DO NOT ALLOW ALL MANUFACTURER'S RECOMMENDATIONS TO BE MET, THE
INSTALLING CONTRACTOR SHALL SUBMIT IN WRITING TO THE ARCHITECT THE
PROPOSED DEVIATION, IN A SKETCH FORM, ACCOMPANIED BY THE
MANUFACTURER'S CONCURRENCE.
ARCHITECTURAL SHEET INDEX
SHEET DESCRIPTION 04
/2
3/
0% O
W N
E R
R E
V
IE
W
/1
1/
F
IN
A
L O
W N
E R
R E
V
IE
W
A-001 GENERAL PROJECT INFORMATION ● ●
A-002 GENERAL PROJECT INFORMATION ● ●
A-003 CODE SUMMARY ● ●
AD111 FIRST FLOOR DEMOLITION PLANS ● ●
A-101 FIRST FLOOR ARCHITECTURAL PLAN ● ●
A-111 FIRST FLOOR FINISH PLAN ● ●
A-141 FIRST FLOOR REFLECTED CEILING PLAN ● ●
A-151 ARCHITECTURAL ROOF PLAN ● ●
A-301 MILLWORK SECTIONS ●
A-401 ENLARGED ARCHITECTURAL PLANS ● ●
A-410 INTERIOR ELEVATIONS ●
A-501 ARCHITECTURAL DETAILS ●
A-601 DOOR AND FRAME SCHEDULE ●
A-602 FINISH SCHEDULES ●
A-603 WALL SCHEDULE ●
DEMOLITION OF EXISTING INTERIOR WALLS, DOORS, FLOORS, CEILINGS, WIRE
PARTITIONS AND FIXTURES. DEMOLITION OF ALL EXISTING INTERIOR FINISHES.
PREPARE REMAINING STRUCTURE TO RECEIVE NEW FINISHES.
CONSTRUCT NEW INTERIOR WALLS, INCLUDING LOCKER ROOMS, OFFICES, TOILET
ROOM, KITCHENETTE, AND NEW CONCRETE FLOOR. INSTALL NEW CEILINGS,
FIXTURES, CABINETS, AND EQUIPMENT. REPLACE, REMOVE OR REPAIR EXISTING
EXTERIOR FENESTRATION.
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
06/13/25 FINAL OWNER REVIEW
07/29/25 BID
16-18" ACCESSIBLE WATER CLOSETS
17-19" ABUMATORY WATER CLOSETS
3'-0"
1'-0" 2'-0"
60" MIN.
28" MIN.
1'-0"
3'-4"
@ GRAB BAR
LOCATIONS
ONLY
36" MIN.
24" MIN. 12" MIN.
-1
/2
M
IN
M
IN
39" - 41"
M
IN
42" MAX.
12" MAX.
54" MIN.
CL
NOTE: ALL FIXTURE AND ACCESSORY MOUNTING
LOCATIONS ARE BASED ON THE AMERICAN NATIONAL
STANDARD ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES ICC/ANSI A-117.1-2009.
LIGHT SWITCH
OR
THERMOSTAT
SOAP DISH OR
DISPENSER
SANITARY
NAPKIN
DISPENSER
PAPER TOWEL
DISPENSER
AND WASTE
SEAT
COVER
DISPENSER
HAND
DRYER
FIRE ALARM
PULL STATION
FIRE
EXTINGUISHER
CABINET
FIRE
EXTINGUISHER
(WALL MOUNT)
DUPLEX
RECEPTACLE
OR TELEPHONE
JACK
M
IN
M A
X
M
IN
C
L E
A R
ACCESSIBLE
URINAL RIM
HEIGHT
MIRROR
(BARRIER
FREE)
M A
X
V
IE
W
IN
G S
U R
F A
C E
M
A X
T O
B .O
M
IN
TOILET TISSUE
DISPENSER
34"
TO
WALL
M
TOILET TISSUE
DISPENSER AT
GRAB BARS
34"
TO
WALL
M
/2
SANITARY
NAPKIN
DISPOSAL
DRINKING
FOUNTAIN
ACCESSIBLE
TOILET SEAT
HEIGHT
42" TO
WALL, TYP.
46" TO
WALL @
STALLS W/
GRAB BAR
M
IN
T O
B O
T T
O M
A T
S
U R
F A
C E
M
O U
N T
E D
W
A S
T E
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-002
GENERAL PROJECT
INFORMATION
B. REED
SCALE: 1/2" = 1'-0"
TYPICAL GRAB BAR LOCATION PLAN
SCALE: 1/2" = 1'-0"
TYPICAL GRAB BAR MOUNTING HEIGHT
SCALE: 1/4" = 1'-0"
TYPICAL BARRIER FREE TOILET ROOM MOUNTING HEIGHTS
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
BUILDING CODE SUMMARY
PROJECT CITY OF DEARBORN FIRE TRAINING AND EMERGENCY MANAGMENT FACILITY
LOCATION DEARBORN, MI
DESCRIPTION ALTERATIONS TO EXISTING BUILDING TO ACCOMODATE ADMINISTRATIVE AND
TRAINING SERVICES.
- OFFICE SPACE, TRAINING ROOM
- NON-COMBUSTABLE, UNPROTECTED
- NO INCREASE TO BUILDING AREA
APPLICABLE CODES
BUILDING 2021 MICHIGAN BUILDING CODE
ACCESSIBILITY ANSI A117.1 - 2017
MECHANICAL 2021 MICHIGAN MECHANICAL CODE
PLUMBING 2021 MICHIGAN PLUMBING CODE
ELECTRICAL 2023 NATIONAL ELECTRICAL CODE
ENERGY 2021 MICHIGAN ENERGY CODE
2015 INTERNATIONAL FUEL GAS CODE
OTHER 2021 INTERNATIONAL FIRE CODE (AS REFERENCED)
NFPA 101 LIFE SAFETY CODE 2021 (AS REFERENCED)
2021 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS
USE AND OCCUPANCY CLASSIFICATION
B BUISNESS
A-3 TRAINING ROOM
304.1: ADMINISTRATIVE OFFICES
303.4: ASSEMBLY GROUP
BUILDING LIMITATION
ACCESSORY OCCUPANCIES 508.2
BUILDING HEIGHT AND
NUMBER OF STORIES
1 ST / 18 FT (NO CHANGE)
(SECTION 504)
BUILDING AREA 4,195 SF (NO CHANGE)
(SECTION 506)
INCIDENTAL USES TABLE 509
(SECTION 509)
TYPE OF CONSTRUCTION
CONSTRUCTION TYPE TYPE II B NONCOMBUSTIBLE - UNPROTECTED
(NO CHANGE)
MEANS OF EGRESS
OCCUPANT LOAD 122 OCCUPANTS
(SECTION 1004)
EXIT ACCESS TRAVEL
DISTANCE
200 FEET
(SECTION 1017) REFER TO EGRESS PLAN
CORRIDORS GROUP B AND A-3 REQUIRES 0-HR FIRE-RESISTANCE RATING
(SECTION 1020, TABLE 1020.1)
B 2,811 SF
A-3 1,384 SF
BUSINESS (B)
ASSEMBLY (A-3)
PLUMBING FIXTURES SUMMARY
OCCUPANCY CALCULATIONS
BUSINESS (1/100) : 2,811 SF = 29 OCCUPANTS*
ASSEMBLY (1/500) : 1,384 SF = 93 OCCUPANTS*
MWC
FWC
LAV
DF
SS
B=1, A-2=1
B=1, A-2=1
TOTAL : 122 OCCUPANTS*
2M, 2F
* NO CHANGE IN OCCUPANCY
B=1, A-2=1 -
1 -
1 - 1
FIXTURE CALCULATIONS
REQUIRED PROVIDEDEXISTING
SINGLE USE
SHOWER 1M, 1F
EXIT
CODE LEGEND:
TD: 000'
CPT: XXX'
TD: XXX'
CPT: 000'
CAPACITY OF EXIT WIDTH PROVIDED (OCCUPANTS)
OCCUPANTS PER CODE CALCULATIONS
(OCCUPANTS - ACTUAL)
EXIT WIDTH (INCHES - ACTUAL)
2 HOUR FIRE RATED ASSEMBLY (ASSUMED)
TRAVEL DISTANCE TO
EXIT LOCATION;
COMMON PATH OF TRAVEL
PER MBC 2015, TABLE 1006.2.1
MAX LENGTH 75 FT. (A+B)
TRAVEL DISTANCE
PER MBC 2015, TABLE 1017.2
MAX. LENGTH 200 FT. (A+B)
CLASS 2A 10LB. FIRE EXTINGUISHER.
TOP OF EXTINGUISHER 60" A.F.F. MAX.
1 HOUR FIRE RATED ASSEMBLY (ASSUMED)
OCCUPANT START POINT
EXIT DISCHARGE POINT
EGRESS PATH OF TRAVEL
BUSINESS (B)
ASSEMBLY (A-3)
# OF OCCUPANTS IN SPACE
# OF OCCUPANTS MERGING/SPLITTING
FE
X"
XXX
XXX
EOC/CLASSROOM
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
OFFICE
EMERGENCY
MANAGER
OFFICE
MECHANICAL
MEN'S LOCKER
ROOM
WOMEN'S
LOCKER ROOM
TD: 60'
CPT: 11'
TD: 62'
CPT: 16'
TD: 50'
CPT: 11'
TD: 43'
CPT: 16'
TD: 44'
CPT: 6'
TD: 59'
CPT: 6'
TD: 32'
EXIT 3
36"
EXIT 2
36"
EXIT 1
50"
TOILET ROOM
OFFICE
OFFICE
OFFICE
LOBBY
FE
FE
FE
FE
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-003
CODE SUMMARY
B. REED
SCALE: 1/8" = 1'-0"
A-003
2 CODE SUMMARY & EGRESS PLANCODE SUMMARY & EGRESS PLAN
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
1 1 1
PROVIDE BID ALTERNATE:
CONTRACTOR TO PERFORM AN ANALYSIS ON THE EXISTING CONCRETE
FLOOR SLAB. PROVIDE CORES AS NECESSARY (APPROX 10'x10' GRID
PATTERN) TO DETERMINE THE CONDITION OF THE COMPACTED SUB-GRADE
BENEATH THE EXISTING SLAB. IF EXCESSIVE VOIDS ARE DISCOVERED,
PROVIDE AN ALTERNATE SOLUTION TO FILL BENEATH THE EXISTING SLAB
(MUD-JACKING / POLY-JACKING) AND LEVEL THE TOP OF THE SLAB TO ACCEPT
THE NEW FLOORING FINISHES. ALL AFFECTED PLUMBING LINES AND FLOOR
DRAINS ARE TO BE CAPPED/SEALED WHERE NOT REUSED. MATCH TOP OF
SLAB / FINISH FLOOR HEIGHT IN EOC/CLASSROOM 116 WITH REST OF FACILITY.
1 REMOVE EXISTING WINDOW AND FRAME TO
ACCOMMODATE NEW CMU/BRICK WALL INFILL
DEMOLITION KEYNOTES
2 REMOVE EXISTING CMU WALL INFILL, HM DOOR,
FRAME, AND ALL ASSOCIATED HARDWARE TO
ACCOMMODATE NEW CMU/BRICK WALL INFILL
TO MATCH EXISTING.
3 REMOVE EXISTING HM DOOR, FRAME, AND ALL
ASSOCIATED HARDWARE TO ACCOMMODATE
NEW CMU/BRICK WALL INFILL TO MATCH EXISTING
4 REMOVE EXISTING STOREFRONT WINDOW
SYSTEM AND TRANSACTION COUNTER TO
ACCOMMODATE NEW CMU WALL INFILL
5 REMOVE EXISTING CMU PIPE ENCLOSURES
FROM FLOOR UP TO CEILING. REFER TO
MECHANICAL DWGS FOR MORE INFORMATION
6 REMOVE EXISTING WOOD RAMP,
GUARDRAIL/HANDRAIL, METAL THRESHOLD,
AND ALL ASSOCIATED HARDWARE.
7 REMOVE EXISTING CMU PARTIAL HEIGHT
WALLS / CHAIN LINK FENCING ANIMAL
ENCLOSURE IN IT'S ENTIRETY
8 REMOVE EXISTING CONCRETE FLOOR SLAB
AND FLOOR DRAINS AT SHADED AREA. REFER
TO MECHANICAL DWGS FOR ADDITIONAL INFO
9 REMOVE EXISTING "ANIMAL SHELTER" SIGNAGE
AND ALL ASSOCIATED HARDWARE, PATCH AND
REPAIR BRICK TO MATCH EXISTING
10 EXISTING CEILING GRID AND TILE TO BE
REMOVED IN IT'S ENTIRETY, REFER TO MECH &
ELEC DWGS FOR LIGHTING, DIFFUSERS,
GRILLES, ETC.
11 REMOVE EXISTING TOILET PARTITIONS AND ALL
ASSOCIATED HARDWARE
12 REMOVE EXISTING PLUMBING FIXTURES, REFER
TO MECH DWGS
13 PORTION OF EXISTING FLOOR SLAB TO REMAIN
WHERE NOT SHADED, CLEAN AND PREPARE TO
ACCEPT NEW FINISH
14 REMOVE EXISTING WALLS, DOORS, AND ALL
ASSOCIATED ACCESSORIES AND HARDWARE
WHERE SHOWN DASHED, TYP. REFER TO
DEMOLITION LEGEND THIS SHEET
15 REMOVE EXISTING SUSPENDED PLYWOOD
PANELS AND ALL ASSOCIATED HARDWARE
16 REMOVE EXISTING FLOOR TILE, CLEAN AND
PREPARE EXISTING SLAB TO ACCEPT NEW FINISH
17 REMOVE EXISTING ENTRY DOOR AND ALUMINUM
STOREFRONT SYSTEM.
DEMOLITION LEGEND
EXISTING CONSTRUCTION
TO BE REMOVED
EXISTING CONSTRUCTION
TO REMAIN
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :2
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
AD111
FIRST FLOOR
DEMOLITION PLANS
B. REED
GENERAL NOTES
NO. DESCRIPTION
1 FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
START OF ANY WORK.
2 COORDINATE ALL MECHANICAL AND ELECTRICAL
WORK, REFER TO MECHANICAL AND ELECTRICAL
DOCUMENTS.
3 ALL EXISTING REMAINING CONSTRUCTION SHALL BE
PROTECTED DURING DEMOLITION AND
CONSTRUCTION, REPAIR OF DAMAGED EXISTING
FINISHES WILL BE AT CONTRACTORS EXPENSE.
4 CONTRACTORS LOGISTICS AND STAGING PLAN SHALL
INCLUDE SPECIFIC DETAIL ON HOW THE WORK AREA
WILL BE SECURE AND ADJACENT FINISHED AREA
PROTECTED.
5 REFER TO SPECIFICATIONS FOR ITEMS TO BE
RECYCLED AND/OR REUSED. COORDINATE WITH
OWNER.
6 ALL SPACES ARE TO BE CLEANED AND ANY DAMAGE
CAUSED BY THE CONTRACTORS TO BE PATCHED,
REPAIRED, AND/OR PAINTED/REPLACE TO MATCH
ORIGINAL CONDITION ONCE WORK IS COMPLETED.
7 CONTRACTOR TO PROVIDE TEMPORARY BARRICADES
AND OTHER FORMS OF PROTECTION IN ACCORDANCE
WITH ALL OSHA REGULATIONS, AS REQUIRED TO
PROTECT OWNERS PERSONNEL, GENERAL PUBLIC AND
ALL EGRESS ROUTES.
8 PROVIDE TEMPORARY SHORING.BRACING AS
REQUIRED PRIOR TO ANY CONSTRUCTION.
TEMPORARY SHORING/BRACING SHALL REMAIN IN
PLACE UNTIL PERMANENT CONSTRUCTION IS
COMPLETE.
9 CONTRACTOR TO COORDINATE WITH OWNER ALL
STAGING AND LAY DOWN AREAS FOR CONSTRUCTION
MATERIALS, CONTRACTOR PARKING, AND DEMOLITION
REMOVAL.
10 CONTRACTOR IS TO MAINTAIN SECURED WORK AREA
AND FACILITY AT ALL TIMES DURING THE COURSE OF
DEMOLITION AND CONSTRUCTION.
11 CONFIRM TEST REPORTS WITH OWNER PRIOR TO
DEMOLITION WORK IF ASBESTOS, LEAD OR OTHER
HAZARDOUS MATERIALS HAVE BEEN FOUND WITHIN
AREA OF SCOPE. HAZARDOUS MATERIALS WILL BE
REMOVED BY OWNER.
12 MAINTAIN ALL NECESSSARY EGRESS ROUTES AND
SITE ACCESS ROUTES THROUGHOUT THE DURATION
OF CONSTRUCTION.
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR DEMOLITION PLAN
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING DEMOLITION PLAN
0 8' 16' 1/8"=1'-0"
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
WOMEN'S
LOCKER ROOM
MEN'S LOCKER
ROOM
MECHANICAL
EOC/CLASSROOM
OPEN OFFICE
EMERGENCY
MANAGER
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
A-401
A-401
1 1 1
TOILET ROOM
OFFICE
OFFICE
OFFICE
LOBBY
7'-8"
7'-8"
7'-8"
7'-8"
11'-3"
8' -0
7'-10"
'-9
116A
116B
112B
112A
A-401
A-410
.14'-0"
EWC
FE
FE
FE
FE
1 1
A
A
A
A
A
A
B
B
B
B
B
B
B
B
B
B
B
A
A
A
A
B
B
B
A
B
B
100B
9' -1
0"
B
B
BC1
C1
B
ALIGN
100A
ACCENT WALL
LVL 5 FINISH
27 (TYP.)
4'-4" **
'-0
A-501
ELEC PANEL, REFER
TO ELEC DWGS
MATCH TOP OF SLAB / FINISH FLOOR
HEIGHT IN EOC/CLASSROOM 116
WITH REST OF FACILITY.
As
1 NEW CMU/BRICK WALL INFILL WHERE EXISTING
WINDOW / PORTION OF WALL WAS REMOVED,
TOOTH INTO EXISTING, NEW BRICK VENEER TO
MATCH EXISTING (PAINT AT INTERIOR TO MATCH
ADJACENT WALLS, REFER TO FINISH PLANS)
KEYNOTES
2 EXISTING BUILDING HOT WATER HEATER TO
REMAIN, REFER TO MECH DWGS
3 EXISTING BUILDING WATER METER TO REMAIN,
REFER TO MECH DWGS
4 NEW ENTRY DOOR AND ALUMINUM STOREFRONT
SYSTEM, COLOR AND FINISH TO MATCH EXISTING
5 NEW METAL LOCKERS, ON 4" PREFAB METAL BASE
(MATCH LOCKER COLOR), REFER TO ENLARGED PLANS
AND INTERIOR ELEVATIONS FOR ADDITIONAL INFO
6 RECESSED WALK-OFF MAT, REFER TO ENLARGED
PLANS FOR SIZE, LOCATION, AND MORE INFO. PREP
NEW CONCRETE FLOOR SLAB DEPRESSION AS
REQUIRED PER MANUF SPEC
7 NEW WALL MOUNTED TV COORDINATE POWER /
DATA WITH ELEC DWGS, PROVIDE BLOCKING IN
WALL FOR TV MOUNT INSTALLATION
8 NEW WALL MOUNTED WHITE BOARD, REFER TO
INTERIOR ELEVATIONS FOR MORE INFO
9 3'-0" x 3'-0" ACCESSIBLE BARRIER FREE FIBERGLASS
SHOWER INSTALLED PER MANUF SPEC
10 EXISTING FLOOR MOUNTED SERVICE SINK TO
REMAIN
11 SHOWER CURTAIN SELECTED BY OWNER
12 NOT USED
13 PRINTER / COPY - COORDINATE POWER / DATA WITH
ELEC DWGS
14 PAPER TOWEL DISPENSER, MOUNTED PER ADA
STANDARDS, REFER TO SCHEDULE
15 WALL MOUNTED MIRROR, MOUNTED PER ADA
STANDARDS
16 SOLID SURFACE COUNTER TOP WITH INTEGRAL
SINK, REFER TO SCHEDULES AND PLUMB DWGS
17 STANDARD HEIGHT TOILET PARTITIONS
18 CERAMIC TILE ON WET WALLS
19 WALL MOUNTED DUAL DRINKING FOUNTAIN /
BOTTLE FILLING STATION, REFER TO PLUMB & ELEC
20 SHOWER HEAD AND CONTROLS, MOUNTED PER ADA
STANDARDS
21 INSTALL WALL MOUNTED 18" / 36" GRAB BAR,
MOUNTED PER ADA STANDARDS, REFER TO DETAILS
SHEET A-002
22 REFRIGERATOR SELECTED BY OWNER, REFER TO
ELEC DWGS
23 COFFEE MAKER SELECTED BY OWNER, REFER TO
ELEC DWGS
24 HAND SOAP DISPENSER, MOUNTED PER ADA
STANDARDS, REFER TO DETAILS A-002
25 WALL MOUNTED TOILET PAPER DISPENSER, REFER TO
DETAILS SHEET A-002
26 NEW RECESSED LIGHT FIXTURE, REFER TO ELEC.
DWGS. PATCH, REPAIR AND PAINT EXISTING ROOF
SOFFIT TO MATCH EXISTING.
27 PROVIDE NEW SHADES AT ALL EXTERIOR WINDOWS.
BASIS OF DESIGN: MECHO /5 SINGLE MANUAL
ROLLER SHADE; SOHO 1600 (3% OPEN), CHARCOAL
28 REMOVE EXISTING DOOR AND FRAME, RAISE SILL TO
NEW FLOOR LEVEL, INSTALL NEW DOOR & FRAME
AT EXISTING DOOR OPENING
29 6" CONCRETE SLAB w/ THICKENED 12"x24"
CONCRETE SLAB AT PERIMETER, REFER TO DETAILS
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
1:
:0
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-101
FIRST FLOOR
ARCHITECTURAL
PLAN
B. REED
GENERAL NOTES
NO. DESCRIPTION
1 FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
START OF ANY WORK.
2 COORDINATE ALL MECHANICAL AND ELECTRICAL
WORK, REFER TO MECHANICAL AND ELECTRICAL
DOCUMENTS.
3 ALL EXISTING REMAINING CONSTRUCTION SHALL BE
PROTECTED DURING DEMOLITION AND
CONSTRUCTION, REPAIR OF DAMAGED EXISTING
FINISHES WILL BE AT CONTRACTORS EXPENSE.
4 CONTRACTORS LOGISTICS AND STAGING PLAN SHALL
INCLUDE SPECIFIC DETAIL ON HOW THE WORK AREA
WILL BE SECURE AND ADJACENT FINISHED AREA
PROTECTED.
5 REFER TO SPECIFICATIONS FOR ITEMS TO BE
RECYCLED AND/OR REUSED. COORDINATE WITH
OWNER.
6 ALL SPACES ARE TO BE CLEANED AND ANY DAMAGE
CAUSED BY THE CONTRACTORS TO BE PATCHED,
REPAIRED, AND/OR PAINTED/REPLACE TO MATCH
ORIGINAL CONDITION ONCE WORK IS COMPLETED.
7 CONTRACTOR TO PROVIDE TEMPORARY BARRICADES
AND OTHER FORMS OF PROTECTION IN ACCORDANCE
WITH ALL OSHA REGULATIONS, AS REQUIRED TO
PROTECT OWNERS PERSONNEL, GENERAL PUBLIC AND
ALL EGRESS ROUTES.
8 PROVIDE TEMPORARY SHORING.BRACING AS
REQUIRED PRIOR TO ANY CONSTRUCTION.
TEMPORARY SHORING/BRACING SHALL REMAIN IN
PLACE UNTIL PERMANENT CONSTRUCTION IS
COMPLETE.
9 CONTRACTOR TO COORDINATE WITH OWNER ALL
STAGING AND LAY DOWN AREAS FOR CONSTRUCTION
MATERIALS, CONTRACTOR PARKING, AND DEMOLITION
REMOVAL.
10 CONTRACTOR IS TO MAINTAIN SECURED WORK AREA
AND FACILITY AT ALL TIMES DURING THE COURSE OF
DEMOLITION AND CONSTRUCTION.
11 CONFIRM TEST REPORTS WITH OWNER PRIOR TO
DEMOLITION WORK IF ASBESTOS, LEAD OR OTHER
HAZARDOUS MATERIALS HAVE BEEN FOUND WITHIN
AREA OF SCOPE. HAZARDOUS MATERIALS WILL BE
REMOVED BY OWNER.
12 MAINTAIN ALL NECESSSARY EGRESS ROUTES AND
SITE ACCESS ROUTES THROUGHOUT THE DURATION
OF CONSTRUCTION.
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR
ARCHITECTURAL PLAN
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
LOCKER ROOM
MEN'S LOCKER
ROOM 100
LOBBY
OFFICE
OFFICE
OFFICE
TOILET ROOM
MECHANICAL
OPEN OFFICE
EMERGENCY
MANAGER
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
EOC/CLASSROOM
ELEC
LEGEND:
CONC-01
CONC-02
CPT-01
CT-01
THRES-01
THRES-02
WALK-OFF MAT
6 RECESSED WALK-OFF MAT, REFER TO
ENLARGED PLANS FOR SIZE, LOCATION, AND
MORE INFO. PREP NEW CONCRETE FLOOR
SLAB DEPRESSION AS REQUIRED PER MANUF
SPEC
FINISH PLAN KEYNOTES
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
P. HENDERSON
R. ARMSTRONG
24-1312
A-111
FIRST FLOOR
FINISH PLAN
B. REED
GENERAL NOTES
NO. DESCRIPTION
1 FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
START OF ANY WORK.
2 COORDINATE ALL MECHANICAL AND ELECTRICAL
WORK, REFER TO MECHANICAL AND ELECTRICAL
DOCUMENTS.
3 ALL EXISTING REMAINING CONSTRUCTION SHALL BE
PROTECTED DURING DEMOLITION AND
CONSTRUCTION, REPAIR OF DAMAGED EXISTING
FINISHES WILL BE AT CONTRACTORS EXPENSE.
4 CONTRACTORS LOGISTICS AND STAGING PLAN SHALL
INCLUDE SPECIFIC DETAIL ON HOW THE WORK AREA
WILL BE SECURE AND ADJACENT FINISHED AREA
PROTECTED.
5 REFER TO SPECIFICATIONS FOR ITEMS TO BE
RECYCLED AND/OR REUSED. COORDINATE WITH
OWNER.
6 ALL SPACES ARE TO BE CLEANED AND ANY DAMAGE
CAUSED BY THE CONTRACTORS TO BE PATCHED,
REPAIRED, AND/OR PAINTED/REPLACE TO MATCH
ORIGINAL CONDITION ONCE WORK IS COMPLETED.
7 CONTRACTOR TO PROVIDE TEMPORARY BARRICADES
AND OTHER FORMS OF PROTECTION IN ACCORDANCE
WITH ALL OSHA REGULATIONS, AS REQUIRED TO
PROTECT OWNERS PERSONNEL, GENERAL PUBLIC AND
ALL EGRESS ROUTES.
8 PROVIDE TEMPORARY SHORING.BRACING AS
REQUIRED PRIOR TO ANY CONSTRUCTION.
TEMPORARY SHORING/BRACING SHALL REMAIN IN
PLACE UNTIL PERMANENT CONSTRUCTION IS
COMPLETE.
9 CONTRACTOR TO COORDINATE WITH OWNER ALL
STAGING AND LAY DOWN AREAS FOR CONSTRUCTION
MATERIALS, CONTRACTOR PARKING, AND DEMOLITION
REMOVAL.
10 CONTRACTOR IS TO MAINTAIN SECURED WORK AREA
AND FACILITY AT ALL TIMES DURING THE COURSE OF
DEMOLITION AND CONSTRUCTION.
11 CONFIRM TEST REPORTS WITH OWNER PRIOR TO
DEMOLITION WORK IF ASBESTOS, LEAD OR OTHER
HAZARDOUS MATERIALS HAVE BEEN FOUND WITHIN
AREA OF SCOPE. HAZARDOUS MATERIALS WILL BE
REMOVED BY OWNER.
12 MAINTAIN ALL NECESSSARY EGRESS ROUTES AND
SITE ACCESS ROUTES THROUGHOUT THE DURATION
OF CONSTRUCTION.
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR
FLOOR FINISH PLAN
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
GFI/W
P
GFI/W
P
GFI/WP
F
F
F
F
LEGEND:
LAY-IN ACT CEILING
GYP. BOARD CEILING
LIGHT FIXTURE
LIGHT FIXTURE
EMERGENCY
LIGHT FIXTURE
EMERGENCY
LIGHT FIXTURE
EXIT SIGN
OS OCCUPONCY SENSOR
DOWNLIGHT (EMERGENCY)
DOWNLIGHT
RETURN
EXHAUST
SUPPLY DIFFUSER
LIGHT FIXTURE
EMERGENCY
LIGHT FIXTURE
A-401
A-401
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
7' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
NO CEILING
(EXPOSED
STRUCTURE)
NO CEILING
(EXPOSED
STRUCTURE)
26 TYP3
1 NEW CMU/BRICK WALL INFILL WHERE EXISTING
WINDOW / PORTION OF WALL WAS REMOVED,
TOOTH INTO EXISTING, NEW BRICK VENEER TO
MATCH EXISTING (PAINT AT INTERIOR TO MATCH
ADJACENT WALLS, REFER TO FINISH PLANS)
KEYNOTES
2 EXISTING BUILDING HOT WATER HEATER TO
REMAIN, REFER TO MECH DWGS
3 EXISTING BUILDING WATER METER TO REMAIN,
REFER TO MECH DWGS
4 NEW ENTRY DOOR AND ALUMINUM STOREFRONT
SYSTEM, COLOR AND FINISH TO MATCH EXISTING
5 NEW METAL LOCKERS, ON 4" PREFAB METAL BASE
(MATCH LOCKER COLOR), REFER TO ENLARGED PLANS
AND INTERIOR ELEVATIONS FOR ADDITIONAL INFO
6 RECESSED WALK-OFF MAT, REFER TO ENLARGED
PLANS FOR SIZE, LOCATION, AND MORE INFO. PREP
NEW CONCRETE FLOOR SLAB DEPRESSION AS
REQUIRED PER MANUF SPEC
7 NEW WALL MOUNTED TV COORDINATE POWER /
DATA WITH ELEC DWGS, PROVIDE BLOCKING IN
WALL FOR TV MOUNT INSTALLATION
8 NEW WALL MOUNTED WHITE BOARD, REFER TO
INTERIOR ELEVATIONS FOR MORE INFO
9 3'-0" x 3'-0" ACCESSIBLE BARRIER FREE FIBERGLASS
SHOWER INSTALLED PER MANUF SPEC
10 EXISTING FLOOR MOUNTED SERVICE SINK TO
REMAIN
11 SHOWER CURTAIN SELECTED BY OWNER
12 NOT USED
13 PRINTER / COPY - COORDINATE POWER / DATA WITH
ELEC DWGS
14 PAPER TOWEL DISPENSER, MOUNTED PER ADA
STANDARDS, REFER TO SCHEDULE
15 WALL MOUNTED MIRROR, MOUNTED PER ADA
STANDARDS
16 SOLID SURFACE COUNTER TOP WITH INTEGRAL
SINK, REFER TO SCHEDULES AND PLUMB DWGS
17 STANDARD HEIGHT TOILET PARTITIONS
18 CERAMIC TILE ON WET WALLS
19 WALL MOUNTED DUAL DRINKING FOUNTAIN /
BOTTLE FILLING STATION, REFER TO PLUMB & ELEC
20 SHOWER HEAD AND CONTROLS, MOUNTED PER ADA
STANDARDS
21 INSTALL WALL MOUNTED 18" / 36" GRAB BAR,
MOUNTED PER ADA STANDARDS, REFER TO DETAILS
SHEET A-002
22 REFRIGERATOR SELECTED BY OWNER, REFER TO
ELEC DWGS
23 COFFEE MAKER SELECTED BY OWNER, REFER TO
ELEC DWGS
24 HAND SOAP DISPENSER, MOUNTED PER ADA
STANDARDS, REFER TO DETAILS A-002
25 WALL MOUNTED TOILET PAPER DISPENSER, REFER TO
DETAILS SHEET A-002
26 NEW RECESSED LIGHT FIXTURE, REFER TO ELEC.
DWGS. PATCH, REPAIR AND PAINT EXISTING ROOF
SOFFIT TO MATCH EXISTING.
27 PROVIDE NEW SHADES AT ALL EXTERIOR WINDOWS.
BASIS OF DESIGN: MECHO /5 SINGLE MANUAL
ROLLER SHADE; SOHO 1600 (3% OPEN), CHARCOAL
28 REMOVE EXISTING DOOR AND FRAME, RAISE SILL TO
NEW FLOOR LEVEL, INSTALL NEW DOOR & FRAME
AT EXISTING DOOR OPENING
29 6" CONCRETE SLAB w/ THICKENED 12"x24"
CONCRETE SLAB AT PERIMETER, REFER TO DETAILS
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-141
FIRST FLOOR
REFLECTED
CEILING PLAN
B. REED
GENERAL NOTES
NO. DESCRIPTION
1 FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
START OF ANY WORK.
2 COORDINATE ALL MECHANICAL AND ELECTRICAL
WORK, REFER TO MECHANICAL AND ELECTRICAL
DOCUMENTS.
3 ALL EXISTING REMAINING CONSTRUCTION SHALL BE
PROTECTED DURING DEMOLITION AND
CONSTRUCTION, REPAIR OF DAMAGED EXISTING
FINISHES WILL BE AT CONTRACTORS EXPENSE.
4 CONTRACTORS LOGISTICS AND STAGING PLAN SHALL
INCLUDE SPECIFIC DETAIL ON HOW THE WORK AREA
WILL BE SECURE AND ADJACENT FINISHED AREA
PROTECTED.
5 REFER TO SPECIFICATIONS FOR ITEMS TO BE
RECYCLED AND/OR REUSED. COORDINATE WITH
OWNER.
6 ALL SPACES ARE TO BE CLEANED AND ANY DAMAGE
CAUSED BY THE CONTRACTORS TO BE PATCHED,
REPAIRED, AND/OR PAINTED/REPLACE TO MATCH
ORIGINAL CONDITION ONCE WORK IS COMPLETED.
7 CONTRACTOR TO PROVIDE TEMPORARY BARRICADES
AND OTHER FORMS OF PROTECTION IN ACCORDANCE
WITH ALL OSHA REGULATIONS, AS REQUIRED TO
PROTECT OWNERS PERSONNEL, GENERAL PUBLIC AND
ALL EGRESS ROUTES.
8 PROVIDE TEMPORARY SHORING.BRACING AS
REQUIRED PRIOR TO ANY CONSTRUCTION.
TEMPORARY SHORING/BRACING SHALL REMAIN IN
PLACE UNTIL PERMANENT CONSTRUCTION IS
COMPLETE.
9 CONTRACTOR TO COORDINATE WITH OWNER ALL
STAGING AND LAY DOWN AREAS FOR CONSTRUCTION
MATERIALS, CONTRACTOR PARKING, AND DEMOLITION
REMOVAL.
10 CONTRACTOR IS TO MAINTAIN SECURED WORK AREA
AND FACILITY AT ALL TIMES DURING THE COURSE OF
DEMOLITION AND CONSTRUCTION.
11 CONFIRM TEST REPORTS WITH OWNER PRIOR TO
DEMOLITION WORK IF ASBESTOS, LEAD OR OTHER
HAZARDOUS MATERIALS HAVE BEEN FOUND WITHIN
AREA OF SCOPE. HAZARDOUS MATERIALS WILL BE
REMOVED BY OWNER.
12 MAINTAIN ALL NECESSSARY EGRESS ROUTES AND
SITE ACCESS ROUTES THROUGHOUT THE DURATION
OF CONSTRUCTION.
SCALE:
NORTH
1/8" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
A-501
A-501
A-501
A-501
A-501
RTU-1
RTU-2
RTU-3
EF-1
SLO
PE
SLO
PE
1 NEW ROOFTOP UNIT, REFER TO MECH DWGS.
ROOF PLAN KEYNOTES
2 NEW VENT THROUGH ROOF, REFER TO MECH
DWGS.
3 NEW EXHAUST FAN, REFER TO MECH DWGS.
4 EXISTING ROOF DRAIN, REFER TO MECH DWGS.
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l e m e n t e S i e g e l D e s i g n I n c .
These documents are instruments of service for use solely with respect to this project. DSD and DSD consultants shall be deemed the authors and owners of their respective instruments of service and shall retain all common law, statutory and other reserved rights, including copyrights.
DSD grants to the owner a nonexclusive license to reproduce DSD's instruments of service solely for the purpose of constructing, using and maintaining this project.
These documents are traditional plan and specification documents that are not intended to be used by the contractor as shop drawings. Final dimensions, equipment access, routing, miscellaneous fittings, final installation and coordination is the contractor's responsibility.
DiClemente Siegel Design Inc.
ARCHITECTURE
& ENGINEERING
D E S I G N E R :
D R A W N :
P M / P I C :
C H E C K E D :
P R O J E C T N O .
Celebrating 50 Years
S i n c e 1 9 6 9
A / E S E A L
S H E E T T I T L E
S H E E T N U M B E R
DEARBORN FIRE
DEPARTMENT TRAINING
& EMERGENCY
MANAGEMENT FACILITY
2661 GREENFIELD RD.
DEARBORN, MI 48120
C U s e rs m ro s s i\ D o c u m e n ts A R B u ff a lo R u n .r v t
:1 :1
P M
P. HENDERSON
M. ROSSI
R. ARMSTRONG
24-1312
A-151
ARCHITECTURAL
ROOF PLAN
B. REEDSCALE:
NORTH
1/8" = 1'-0"
ARCHITECTURAL ROOF PLAN
GENERAL NOTES
NO. DESCRIPTION
1 FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO
START OF ANY WORK.
2 COORDINATE ALL MECHANICAL AND ELECTRICAL
WORK, REFER TO MECHANICAL AND ELECTRICAL
DOCUMENTS.
3 ALL EXISTING REMAINING CONSTRUCTION SHALL BE
PROTECTED DURING DEMOLITION AND
CONSTRUCTION, REPAIR OF DAMAGED EXISTING
FINISHES WILL BE AT CONTRACTORS EXPENSE.
4 CONTRACTORS LOGISTICS AND STAGING PLAN SHALL
INCLUDE SPECIFIC DETAIL ON HOW THE WORK AREA
WILL BE SECURE AND ADJACENT FINISHED AREA
PROTECTED.
5 REFER TO SPECIFICATIONS FOR ITEMS TO BE
RECYCLED AND/OR REUSED. COORDINATE WITH
OWNER.
6 ALL SPACES ARE TO BE CLEANED AND ANY DAMAGE
CAUSED BY THE CONTRACTORS TO BE PATCHED,
REPAIRED, AND/OR PAINTED/REPLACE TO MATCH
ORIGINAL CONDITION ONCE WORK IS COMPLETED.
7 CONTRACTOR TO PROVIDE TEMPORARY BARRICADES
AND OTHER FORMS OF PROTECTION IN ACCORDANCE
WITH ALL OSHA REGULATIONS, AS REQUIRED TO
PROTECT OWNERS PERSONNEL, GENERAL PUBLIC AND
ALL EGRESS ROUTES.
8 PROVIDE TEMPORARY SHORING.BRACING AS
REQUIRED PRIOR TO ANY CONSTRUCTION.
TEMPORARY SHORING/BRACING SHALL REMAIN IN
PLACE UNTIL PERMANENT CONSTRUCTION IS
COMPLETE.
9 CONTRACTOR TO COORDINATE WITH OWNER ALL
STAGING AND LAY DOWN AREAS FOR CONSTRUCTION
MATERIALS, CONTRACTOR PARKING, AND DEMOLITION
REMOVAL.
10 CONTRACTOR IS TO MAINTAIN SECURED WORK AREA
AND FACILITY AT ALL TIMES DURING THE COURSE OF
DEMOLITION AND CONSTRUCTION.
11 CONFIRM TEST REPORTS WITH OWNER PRIOR TO
DEMOLITION WORK IF ASBESTOS, LEAD OR OTHER
HAZARDOUS MATERIALS HAVE BEEN FOUND WITHIN
AREA OF SCOPE. HAZARDOUS MATERIALS WILL BE
REMOVED BY OWNER.
12 MAINTAIN ALL NECESSSARY EGRESS ROUTES AND
SITE ACCESS ROUTES THROUGHOUT THE DURATION
OF CONSTRUCTION.
0 8' 16' 1/8"=1'-0"
DATE ISSUED FOR:
04/23/25 50% OWNER REVIEW
3/4" SOLID SURFACE
VERTICAL EDGE/FACE,
POLISH FOR SEAMLESS
TRANSITION
3/4" SOLID SURFACE
COUNTERTOP
DOOR SHELF
HARDWARE
3/4" PLYWOOD
DOOR W/ P. LAM.
ON ALL EXPOSED
SURFACES
HEAVY DUTY
CABINET DOOR
HINGE, TYP.
PROVIDE SOLID WOOD FASCIA
W/ P. LAM. FINISH WHERE
SHEATHING IS LAYERED
4" TOE-KICK TO MATCH CABINETS
TREATED 2X WOOD
BLOCKING/NAILER
TREATED 2X WOOD
BLOCKING/NAILER
SHIM AS REQUIRED
2X WOOD STRETCHERS
@24" O.C.
3/4" PLYWOOD
BOTTOM PANEL W/
P. LAM. FINISH
3/4" PLYWOOD SIDE
PANEL W/ P. LAM.
FINISH, BEYOND
3/4" PLYWOOD
BACK PANEL W/
P. LAM. FINISH
3/4" PLYWOOD
ADJUSTABLE SHELF W/
P. LAM. FINISH & RECESSED
SHELF STANDARDS
5/8" GYP. BD. ON
STUD FRAMING; REFER
TO PLANS FOR
INSULATION
REQUIREMENTS
INTERMEDIATE 2X4 NON-
COMBUSTIBLE WOOD
BRACING AT COUNTERS
AND CABINETS, TYP.
WALL TILE THINSET OVER
1/2" (U.O.N.) TILE BACKER
BOARD, REFER TO
SCHEDULES
NEW 3 5/8" METAL
STUD FRAMING @ 16"
O.C., TYP.
3/4" PLYWOOD BOARD
W/ P. LAM. FINISH
NEW CEILING
SYSTEM,
REFER TO
SCHEDULES
5/8" GYP. BD.
ON NEW STUD
FRAMING
2'-1"
/2
PULL, TYP.
/2
3" 4
/2
/4
PLYWOOD
DRAWER W/
P. LAM. FINISH
ON HEAVY DUTY
FULL EXTENSION
GUIDES
/4
3/4" PLYWOOD
ADJUSTABLE SHELF W/
P. LAM. FINISH & RECESSED
SHELF STANDARDS
HEAVY DUTY
CABINET DOOR
HINGE, TYP.
DOOR SHELF
HARDWARE
PULL, TYP.
PROVIDE SOLID WOOD FASCIA
W/ P. LAM. FINISH WHERE
SHEATHING IS LAYERED
3/4" PLYWOOD
BACK PANEL W/
P. LAM. FINISH
3/4" PLYWOOD SIDE
PANEL W/ P. LAM.
FINISH, BEYOND
1'-0 1/2"
3/4" PLYWOOD
BOTTOM PANEL W/
P. LAM. FINISH
1'-4"
3/4" SOLID SURFACE
VERTICAL EDGE/FACE,
POLISH FOR SEAMLESS
TRANSITION
PULL, TYP.
3/4" PLYWOOD
DOOR W/ P. LAM.
ON ALL EXPOSED
SURFACES
HEAVY DUTY
CABINET DOOR
HINGE, TYP.
PROVIDE SOLID WOOD FASCIA
W/ P. LAM. FINISH WHERE
SHEATHING IS LAYERED
4" TOE-KICK TO MATCH CABINETS
TREATED 2X WOOD
BLOCKING/NAILER
TREATED 2X WOOD
BLOCKING/NAILER
SHIM AS REQUIRED
2X WOOD STRETCHERS
@24" O.C.
3/4" PLYWOOD
BOTTOM PANEL W/
P. LAM. FINISH
3/4" PLYWOOD SIDE
PANEL W/ P. LAM.
FINISH, BEYOND
3/4" PLYWOOD
BACK PANEL W/
P. LAM. FINISH
5/8" GYP. BD. ON
STUD FRAMING
INTERMEDIATE 2X4 NON-
COMBUSTIBLE WOOD
BRACING AT COUNTERS
AND CABINETS, TYP.
WALL TILE THINSET OVER
1/2" (U.O.N.) TILE BACKER
BOARD, REFER TO
SCHEDULES
PROVIDE FALSE
OVERLAY OF
DRAWER AT SINK
FALSE PULL
COPE & ANGLE COUNTERTOP
TO ALLOW FOR SINK
INSTALLATION, BEYOND
UNDERMOUNT SINK W/
GARBAGE DISPOSAL, PROVIDE
OPENING, FRAMING & COPE AS
REQ'D; REFER TO MECH. & ELECT.
3/4" SOLID SURFACE
COUNTERTOP
COUNTERTOP
MOUNTED FAUCET,
REFER TO MECH.
2'-1"
/2
3" 4
/2
NEW 16 GA. 3 5/8"
METAL STUD
FRAMING @ 24"O.C.
SIZE COVER TO CONCEAL PLUMBING,
ANCHOR TO WALL, WALL ANCHOR
COLOR TO MATCH COVER COLOR
6" TILE BASE,
REFER TO SCHEDULES
REFER TO SCHEDULES FOR FLOOR
FINISHES
LINE/AREA OF KNEE AND TOE
CLEARANCE TO BE MAINTAINED
3/4" PLYWOOD W/ P.LAM ON ALL EXPOSED
SURFACES.
PROVIDE CONT. L 3 1/2" x 3 1/2" x 1/4"
STRUCTURAL STEEL ANGLES @ 24" O.C. INTO
METAL STUD FRAMING @ EACH END. PROVIDE
L 3 1/2" x 3 1/2" x 1/4" STRUCTURAL STEEL
ANGLE CENTER SUPPORT @ ALL COUNTERS
GREATER THAN 10'-0" IN LENGTH, REFER TO
FRAMING DIAGRAM X/A-50X
PROVIDE CONT. L 3 1/2" x 3 1/2" x 1/4"
STRUCTURAL STEEL ANGLES W/ 1/2" DIA. ANCHORS
@ 24" O.C. INTO METAL STUD FRAMING,
REFER TO FRAMING DIAGRAM X/A-50X, TYP.
PROVIDE CONT. LAYER OF BUTYL
SEALANT BETWEEN COUNTER AND
SINK MOUNTING LIP
SOLID SURFACE VERTICAL
FACE / LEDGE, SHIM AS REQ'D
SOLID SURFACE, VERTICAL EDGE / FACE
POLISH FOR SEAMLESS
TRANSITION
UNDERMOUNT S.S. SINK,
PROVIDE OPENING, FRAMING &
COPE AS REQ'D; REFER TO MECH.
4" HIGH SOLID SURFACE
BACK SPLASH
REFER TO SCHEDULES
COUNTERTOP MOUNTED FAUCET,
REFER TO MECH.
FULL HEIGHT MIRROR, REFER
TO SCHEDULES
WALL TILE THINSET OVER 1/2"
(U.O.N.) TILE BACKER BOARD,
REFER TO SCHEDULES
2x6 NON-
COMBUSTIBLE SOLID
WOOD BLOCKING
8" MIN.
M
IN
M
IN
11" MIN.
3/4" PLYWOOD SUPPORT
PANEL W/ P.LAM FINISH
5/8" GYP. BD. ON
STUD FRAMING
2'-1"
3 5/8" METAL STUD
FRAMING @ 16" O.C.
3/4" SOLID SURFACE
VERTICAL EDGE/FACE,
POLISH FOR SEALMLESS
TRANSITION
3/4" SOLID SURFACE
COUNTERTOP
PROVIDE SOLID WOOD FASCIA
W/ P. LAM. FINISH WHERE
SHEATHING IS LAYERED
4" TOE-KICK TO MATCH CABINETS
TREATED 2X WOOD
BLOCKING/NAILER
SHIM AS REQUIRED
2X WOOD STRETCHERS
@24" O.C.
3/4" PLYWOOD
BOTTOM PANEL W/
P. LAM. FINISH
PLYWOOD DRAWERS W/
P. LAM. FINISH ON ALL
EXPOSED FACES, TYP.
5/8" GYP. BD. ON
STUD FRAMING; REFER
TO PLANS FOR
INSULATION
REQUIREMENTS
INTERMEDIATE 2X4 NON-
COMBUSTIBLE WOOD
BRACING AT COUNTERS
AND CABINETS, TYP.
WALL TILE THINSET OVER
1/2" (U.O.N.) TILE BACKER
BOARD, REFER TO
SCHEDULES
2'-1"
/2
/4
/4
/2
/2
"3/4" PLYWOOD
BACK PANEL W/
P. LAM. FINISH
(2) 3/4" PLYWOOD
BOTTOM PANEL W/
P. LAM. FINISH
MICROWAVE
2 8 1 0 5 G r e e n f i e l d R d S o u t h f i e l d , M I 4 8 0 7 6 - 3 0 4 6 V o i c e : 2 4 8 . 5 6 9 . 1 4 3 0 F a x : 2 4 8 . 5 6 9 . 0 0 9 6
E m a i l : m k t g @ d s d o n l i n e . c o m W e b s i t e : h t t p : / / d s d o n l i n e . c o m
© 2 0 2 5 D i C l…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .