DCF ITB 2223 046 Exhibit M - Scope of Services.pdf

PDF 21 MB Posted

Attached to
Northeast FL State Hospital Roofing Project# 33020300
Solicitation number
ITB-02747
Issued by
Baker County, Florida

About this file

The document provided is the Scope of Services for Invitation to Bid (ITB) 2223 046 issued by the Florida Department of Children and Families (DCF), General Services. The ITB seeks bids for providing a new metal roof system over an existing asphalt shingles roof system for Buildings 3, 4, 5, 6, 7, 8, 9, 10, and 16 at the Northeast Florida State Hospital. The existing roof system consists of a sloping asphalt shingle roof over poured gypsum over formboard on steel roof trusses. The contractor shall install new "Z" purlins screw-attached to the steel roof trusses and cover with new specified galvalume metal roof panels. The notice of intent to award has been posted, and the project number is 33020300.

The ITB does not provide information on pricing terms, set asides, incumbents, funding requirements, or other salient details. It solely focuses on the scope of services required for the roofing project.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

A L

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

2NORTHEAST FLORIDA STATE HOSPITAL

7487 SOUTH STATE ROAD 121

MACCLENNY, FLORIDA 32062

FLORIDA DEPARTMENT OF CHILDREN & FAMILIES

RE-ROOF BUILDINGS 7, 8, 9, 10, 16, 3, 4, 5, AND 6

VICINITY MAPPROJECT LOCATION MAP

NORTHNORTH

PROJECT SITE

PROJECT SITE

COVER SHEET

BHA

BSS

G001

FLORIDA DEPT. OF CHILDREN & FAMILIES

2415 NORTH MONROE STREET, SUITE 400, RM J202

TALLAHASSEE, FLORIDA 32303

PHONE: (850) 717-4011

PROJECT CONTACTS:

BHIDE & HALL ARCHITECTS, P.A.

1329 KINGSLEY AVENUE, SUITE C

ORANGE PARK, FLORIDA 32073

PHONE: (904) 264-1919

STRUCTURES INTERNATIONAL, LLC

7563 PHILIPS HIGHWAY, BUILDING 600

JACKSONVILLE, FLORIDA 32256

PHONE: (904) 296-2646

OWNER STRUCTURAL ENGINEERARCHITECT

DCF PROJECT NO. 33020300

BID SUBMITTAL

SEPTEMBER 27, 2022

johns-sally Sticky Note Disregard this date, refer to ITB posting.

A/C air conditioning

AB anchor bolt

ABV above

ACOUS acoustical

ADH adhesive

ADJ adjustable

AFF above finished floor

ALT alternate

ALUM aluminum

APPROX approximate

ARCH architect(ural)

BD board

BLDG building

BLK block

BLKG blocking

BM benchmark

BOT bottom

BPL bearing plate

BRG bearing

CAB cabinet CAR carpet

CER ceramic

CF cubic foot

CJ control joint

CH ceiling height

CLG ceiling

CLR clear(ance)

CMU concrete masonry unit

COL column CONC concrete

CONT continuous or continue

CORR corrugated

CSE course(s)

CT ceramic tile

CY cubic yard

DT detail

DF drinking fountain

DH dropped header

DIA diameter

DIM dimension

DR door

DS downspout

DWG drawing E east

EL elevation

ELEC electrical

ELEV elevator

EQ equal

EQUIP equipment

EWC electric water cooler

EXH exhaust

EXIST existing

EXP exposed

EXT exterior

FA fire alarm

FBC Florida Building Code

FE fire extinguisher

FEC fire extinguisher cabinet

FF finished floor

FIN finish(ed)

FLR floor

FLUOR fluorescent

FPL fireplace

FTG footing GA gauge

GALV galvanized GYP gypsum

HB hose bib

H/C handicapped

HC hollow core

HDR header

HDW hardware

HM hollow metal

HORIZ horizontal

HT height

HVAC heating / ventillation

/ air conditioning

ID inside diameter

INSUL insulate(d) (ion)

INT interior

INV invert

JT joint

KT kitchen

L length

LAB laboratory

LAM laminate(d)

LAV lavatory

LB load bearing

LT light

LVR louver

MAX maximum

MECH mechanical

MFR manufacturer

MIN minimum

MISC miscellaneous

MO masonry opening

MT metal threshold

MTL metal

MULL mullion

N north

NIC not in contract

NLB non-load bearing

NOA Notice of Acceptance

NOM nominal

NTS not to scale OC on center

OD outside diameter

OPG opening

OPH opposite hand

OPP opposite

OSB oriented strand board

PCF pounds per cubic foot

PL plate

PL property line

PLAS plastic

PLYWD plywood

PREFAB prefabricated

PREFIN prefinished

PSF pounds per square foot

PSI pounds per square inch

PT pressure treated

PVC polyvinyl chloride PVMT pavement

QT quarry tile

R riser

RA return air

RAD radius

REF refrigerator

REV revision(s), revised

RCP reflected ceiling plan RM room

RO rough opening

S south

SC solid core

SCHED schedule

SECT section

SF square foot (feet)

SH shelf, shelving

SHT sheet

SIM similar

SPEC specification(s) SQ square

SS stainless steel

STD standard

STR'L structural

STL steel STOR storage

SUSP suspended

T&G tongue and groove

T tread

TEL telephone

THK thick(ness)

TV television

TYP typical

UNO unless noted otherwise

VCT vinyl composition tile

VERT vertical W west

W width, wide

WC water closet

WD wood

WH water heater

WIN window

WWF welded wire fabric

TYPICAL ABBREVIATIONS

GENERAL NOTES

1. ALL WORK TO COMPLY WITH APPLICABLE

CODES. THE CONTRACTOR MUST COMPLY WITH THE

RULES AND REGULATIONS OF AGENCIES HAVING

JURISDICTION AND TO CONFORM TO ALL CITY,

COUNTY, STATE AND FEDERAL CONSTRUCTION,

SAFETY AND SANITARY LAWS, CODES, STATUES

AND ORDINANCES.

2. ALL FEES, TAXES, PERMITS, APPLICATIONS

AND CERTIFICATES OF INSPECTION AND THE FILING

OF ALL WORK WITH GOVERNMENTAL AGENCIES TO

BE THE RESPONSIBILITY OF THE CONTRACTOR.

CONTRACTOR TO OBTAIN ANY NECESSARY PERMITS

AND APPROVALS PRIOR TO COMMENCEMENT WITH

THE WORK, IF NECESSARY.

3. ALL WORK SHALL BE PERFORMED BY SKILLED

AND QUALIFIED WORKMEN IN ACCORDANCE WITH

THE BEST PRACTICES OF THE TRADES INVOLVED

AND IN COMPLIANCE WITH BUILDING REGULATIONS

AND/OR GOVERNMENT LAWS, STATUTES OR

ORDINANCES CONCERNING THE USE OF UNION

LABOR.

4. CONTRACTOR AND SUB-CONTRACTORS TO

FIELD VERIFY ALL DIMENSIONS AND CONDITIONS

SHOWN ON DOCUMENTS AND MUST NOTIFY

ARCHITECT OF ANY DISCREPANCIES, OMISSIONS

AND/OR CONFLICTS PRIOR TO PROCEEDING WITH

THE WORK.

5. EACH TRADE WILL BE EXPECTED TO PROCEED

IN A FASHION THAT WILL NOT DELAY OTHER

TRADES.

6. THE CONTRACTOR IS RESPONSIBLE FOR THE

DISTRIBUTION OF ALL DRAWINGS TO ALL TRADES

UNDER THEIR JURISDICTION.

7. ALL MATERIALS TO BE NEW, UNUSED AND OF

THE HIGHEST QUALITY IN EVERY RESPECT, UNLESS

OTHERWISE NOTED. MANUFACTURED MATERIALS

AND EQUIPMENT TO BE STORED AND INSTALLED IN

ACCORDANCE WITH THE MANUFACTURER'S

WRITTEN RECOMMENDATIONS AND INSTRUCTIONS.

8. ALL WORK AND MATERIALS TO BE

GUARANTEED AGAINST DEFECTS FOR A PERIOD OF

NOT LESS THAN ONE (1) YEAR AFTER APPROVAL OF

FINAL PAYMENT.

9. THE CONTRACTOR IS RESPONSIBLE FOR

CUTTING AND PATCHING REQUIRED FOR HIS WORK

UNLESS OTHERWISE NOTED.

10. THE CONTRACTOR TO, AT ALL TIMES, KEEP

THE PREMISES FREE OF ACCUMULATION OF WASTE

MATERIALS OR RUBBISH; PREMISES TO BE SWEPT

CLEAN DAILY.

11. THE CONTRACTOR TO PROVIDE FINAL

CLEANING OF ALL AREAS OF WORK INCLUDING THE

CONSTRUCTION ACCESS ROUTE. FINAL CLEANING

TO INCLUDE WINDOWS AND CEILINGS.

12. DO NOT SCALE DRAWINGS; DIMENSIONS

GOVERN. LARGER SCALE DRAWINGS TO GOVERN

OVER SMALLER SCALE DRAWINGS.

13. IF DIMENSIONS ARE IN QUESTION, THE

CONTRACTOR IS RESPONSIBLE TO GET

CLARIFICATION AND DIRECTION FROM ARCHITECT

PRIOR TO PROCEEDING WITH THE WORK.

14. ALL RE-INSTALLED PLUMBING, MECHANICAL

AND ELECTRICAL EQUIPMENT TO OPERATE QUIETLY

AND BE FREE OF VIBRATION.

15. ALL SURFACES TO BE PROPERLY PRIMED OR

PREPARED PRIOR TO INSTALLATION OF SPECIFIED

FINISHES.

16. ALL FINISHES TO BE INSTALLED IN

ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATIONS AND INSTRUCTIONS FOR THE

TYPE OF MATERIAL AND INSTALLATION SPECIFIED.

17. PAINT TO BE APPLIED IN ACCORDANCE WITH

THE MANUFACTURER'S DIRECTIONS OVER

PROPERLY PREPARED SURFACES. PROVIDE

MINIMUM ONE COAT PRIME AND ONE FINISH COAT.

FINISHED COAT TO COMPLETELY COVER WITH NO

STREAKING OR BLEEDING OF UNDERCOATS.

18. UPON COMPLETION OF THE WORK, THE

CONTRACTOR TO NOTIFY OWNER THAT THE

PROJECT IS READY FOR INSPECTION. OWNER WILL

COMPILE A "PUNCH LIST" OF CORRECTIONS NEEDED,

OF UNSATISFACTORY AND/OR INCOMPLETE WORK.

FINAL PAYMENT WILL BE CONTINGENT UPON THE

SUCCESSFUL COMPLETION OF THE PUNCH LIST.

19. DIMENSIONS ARE TO THE FINISHED FACE OF

EXISTING CONSTRUCTION OR TO FACE OF NEW

FRAME OR MASONRY WALL (MINUS FINAL FINISH).

DIMENSIONS ARE NOMINAL UNLESS OTHERWISE

INDICATED.

20. ALL WORK TO BE SCHEDULED DURING

REGULAR BUSINESS HOURS UNLESS NOTED

OTHERWISE.

D#

DESCRIPTION

EL. #'-##"

XX

A##.#

XX

L# demolition note mark

LC

A

X

X A##.#

X A##.#

XX

SCALE:

SYMBOL LEGEND

AS NEEDED

A#.# brick concrete conc. masonry units

(CMU) in plan conc. masonry units

(CMU) in section, hatch scale varies earth marble metal (large scale) metal (small scale) plaster, cement, sand, grout, stucco plywood porous fill

(stone or gravel) stucco, cement, (elevation) glass in elevation gypsum board insulation

(loose or batt) insulation (rigid) terrazzo wood (finished) wood (rough, cont) wood (rough, non-cont, blocking) room number elevation (section) column grid detail number / letter sheet where drawn section number / letter sheet where drawn revision mark clouded indicates extent of revision interior elevation mark louver mark window mark door mark wall mark bldg section number / letter sheet where drawn equipment mark kitchen

ELEVATION elevation (plan) split-face concrete masonry units

(CMU) in plan split-face concrete masonry units

(CMU) in section

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DRAWING INDEX,

CODE SUMMARY,

ALTERNATES,

AND GENERAL NOTES

BHA

BSS

G002

INDEX OF DRAWINGS

SHEET

NO.

NAME

REVISION

NO.

REVISION

DATE

GENERAL

G001 COVER SHEET C 09/09/2022

G002 DRAWING INDEX, CODE SUMMARY,

ALTERNATES, AND GENERAL NOTES

C 09/09/2022

ARCHITECTURAL

AD201 DEMOLITION ROOF PLAN - BUILDING 7

BASE BID

C 09/09/2022

AD202 DEMOLITION ROOF PLAN - BUILDING 8

BASE BID

C 09/09/2022

AD203

DEMOLITION ROOF PLAN - BUILDING 9

ALTERNATE 3

C 09/09/2022

AD204

DEMOLITION ROOF PLAN - BUILDING 10

BASE BID

C 09/09/2022

AD205

DEMOLITION ROOF PLAN - BUILDING 16

ALTERNATE 4

C 09/09/2022

AD206

DEMOLITION ROOF PLAN - BUILDING 3

BASE BID

C 09/09/2022

AD207

DEMOLITION ROOF PLAN - BUILDING 4

BASE BID

C 09/09/2022

AD208

DEMOLITION ROOF PLAN - BUILDING 5

ALTERNATE 1

C 09/09/2022

AD209

DEMOLITION ROOF PLAN - BUILDING 6

ALTERNATE 2

C 09/09/2022

A201 RENOVATION ROOF PLAN - BUILDING 7

BASE BID

C 09/09/2022

A202 RENOVATION ROOF PLAN - BUILDING 8

BASE BID

C 09/09/2022

A203

RENOVATION ROOF PLAN - BUILDING 9

ALTERNATE 3

C 09/09/2022

A204

RENOVATION ROOF PLAN - BUILDING 10

BASE BID

C 09/09/2022

A205

RENOVATION ROOF PLAN - BUILDING 16

ALTERNATE 4

C 09/09/2022

A206

RENOVATION ROOF PLAN - BUILDING 3

BASE BID

C 09/09/2022

A207

RENOVATION ROOF PLAN - BUILDING 4

BASE BID

C 09/09/2022

A208

RENOVATION ROOF PLAN - BUILDING 5

ALTERNATE 1

C 09/09/2022

A209

RENOVATION ROOF PLAN - BUILDING 6

ALTERNATE 2

C 09/09/2022

A301 TYPICAL SECTION & DETAILS C 09/09/2022

A302 TYPICAL DETAILS C 09/09/2022

AD901 REFERENCE PHOTOS C 09/09/2022

G003 BUILDING LOCATION SITE PLAN C 09/09/2022

STRUCTURAL

S101 ROOF WIND DESIGN PRESSURES -

BUILDINGS 7, 8, 9, & 10

C 09/09/2022

S102 C 09/09/2022

S103 C 09/09/2022

ROOF WIND DESIGN PRESSURES -

BUILDINGS 3, 4, & 16

ROOF WIND DESIGN PRESSURES -

BUILDINGS 5, & 6

A303 TYPICAL DETAILS C 09/09/2022

S000 GENERAL NOTES & DESIGN CRITERIA &

TYPICAL DETAILS

C 09/09/2022

ALTERNATES / ALTERNATE BID ITEMS (ABIs):

CONTRACTOR TO SEE SPECIFICATION 01 23 00 FOR ADDITIONAL INFORMATION.

BUILDING CODE SUMMARY

GENERAL INFORMATION:

THIS PROJECT IS FOR THE INSTALLATION OF A NEW COMMERCIAL ROOF SYSTEM OVER THE

EXISTING ORIGINAL ROOF AND/OR ROOF STRUCTURE ON FOUR BUILDINGS AT THE N.E. FLORIDA

STATE HOSPITAL LOCATED IN MACCLENNY FLORIDA. THE EXISTING ORIGINAL ROOF IS ASPHALT SHINGLE ROOFING OVER 2" POURED GYPSUM OVER 1/2" FORM BOARD ATTACHED TO STEEL ANGLE

TRUSSES. THE EXISTING ROOF SYSTEM IS IN GOOD CONDITION AND WILL REMAIN IN PLACE. A NEW ROOF SYSTEM WILL BE INSTALLED OVER THE EXISTING. THE NEW SYSTEM WILL CONSIST OF A

STANDING SEAM METAL ROOF SYSTEM INSTALLED ON NEW STEEL Z PURLINS OVER NEW

SYNTHETIC UNDERLAYMENT ADHERED TO THE EXISTING ASPHALT SHINGLES. THE NEW ROOF

SLOPE WILL MATCH THE EXISTING 3 IN 12 ROOF SLOPE.

APPLICABLE CODES:

BUILDING CODE: FLORIDA BUILDING CODE, BUILDING, 7TH EDITION, (2020)

FLORIDA BUILDING CODE, EXISTING BUILDING, 7TH EDITION, (2020)

PLUMBING CODE FLORIDA BUILDING CODE, PLUMBING, 7TH EDITION (2017)

MECHANICAL CODE FLORIDA BUILDING CODE, MECHANICAL, 7TH EDITION (2017)

ELECTRICAL CODE FLORIDA BUILDING CODE, ELECTRICAL, 7TH EDITION (2017)

FIRE CODE & FLORIDA FIRE PREVENTION CODE, 7TH EDITION

LIFE SAFETY

CLASSIFICATION OF WORK (ALTERATION - LEVEL 1) - FBC, EXISTING BUILDING CHAPTER 6:

SECTION 602.1 - SCOPE: LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT

OR THE COVERING OF EXISTING MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES USING

NEW MATERIALS, ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME PURPOSE.

THE SCOPE OF WORK INCLUDED IN THIS PROJECT IS CLASSIFIED AS A LEVEL 1

ALTERATION.

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES - FBC CHAPTER 15:

SECTION 1503.4 - ROOF DRAINAGE: UNLESS ROOF ARE SLOPED TO DRAIN OVER ROOF EDGES,

DESIGN AND INSTALLATION OF ROOF DRAINAGE SYSTEMS SHALL COMPLY WITH SECTION

1503 AND THE FLORIDA BUILDING CODE, PLUMBING, CHAPTER 11. THE ROOF WILL BE

SLOPED TO DRAIN OVER EDGES.

TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION:

TYPE IIB CONSTRUCTION = TYPE C CLASSIFICATION.

SECTION 1507.4 - METAL ROOF PANELS: THE INSTALLATION OF METAL ROOF PANELS

SHALL COMPLY WITH THE PROVISIONS OF THIS SECTION.

SECTION 1510.1 REROOFING - THE MINIMUM DESIGN SLOP REQUIREMENT OF ON-QUARTER

UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT SLOPE) IN SECTION 1507 FOR ROOFS

THAT PROVIDE POSITIVE ROOF DRAINAGE: THE NEW ROOF SLOPE WILL MEET THE 1 4" PER

FOOT REQUIRED SLOPE.

SECTION 1511.3 RECOVERING VERSUS REPLACEMENT: NEW ROOF COVERINGS SHALL NOT BE

INSTALLED WITHOUT FIRST REMOVING ALL EXISTING LAYERS OF ROOF COVERINGS DOWN

TO THE ROOF DECK WHERE AND OF THE FOLLOWING CONDITIONS OCCUR - EXISTING BASE IS

WATER SOAKED AND DETERIORATED, ROOF COVERING ..., WHERE THE EXISTING ROOF HAS

TWO OR MORE APPLICATIONS OF ANY TYPE OF ROOF COVERING, WHERE THE ROOF HAS

BLISTERS UNLESS THE BLISTERS ARE REMOVED AND REPAIRED. WHERE ATTACHMENT

REQUIREMENTS PER SECTION 1504.1 CANNOT BE MET. THE EXISTING ORIGINAL ROOF

SYSTEM DOES NOT HAVE ANY OF THESE EXCLUSIONS AND THEREFORE CAN BE

RECOVERED. SYSTEMS ARE IN POOR CONDITION AND ARE BELIEVED TO BE ALLOWING

WATER INTRUSION INTO THE EXISTING ROOFING SYSTEM. THUS, THESE ROOFING

SYSTEMS SHALL BE REMOVED AND REPLACED WITH NEW ROOF SYSTEMS AS LISTED

HEREIN:

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

BUILDING

LOCATION

SITE

PLAN

BHA

BSS

G003SCALE:

BUILDING LOCATION SITE PLAN

NOT TO SCALE N

O R

T H

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RI

DG

E

3:12 SLOPE

86'-6" 51'-0" 112'-2"

249'-8"

'-0

'-0

'-0

13'-3" 6'-

8"

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARVEF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS

EF

ARVARVARVARV EFEF

WS WSWS

WS

WS

WS

EXISTING CANOPY

TO REMAIN

AD901

AD901

AD901

AD901

AD901

AD901

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 7

BASE BID

BHA

BSS

AD201SCALE:

DEMOLITION ROOF PLAN - BUILDING 7 - BASE BID

3/32" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

ADDITIONAL INFORMATION

AS APPLIES.

86'-6" 51'-0" 112'-2"

249'-8"

'-0

'-0

'-0

13'-3" 6'-

8"

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARVEF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS

EF

ARVARVARVARV EFEF

WS WSWS

WS

WS

WS

EXISTING CANOPY

TO REMAIN

AD901

AD901

AD901

AD901

AD901

AD901

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 8

BASE BID

BHA

BSS

AD202SCALE:

DEMOLITION ROOF PLAN - BUILDING 8 - BASE BID

3/32" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

'-0

'-0

'-0

13'-3" 6'-

8"

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARVEF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS

EF

ARVARVARVARV EFEF

WS WSWS

WS

WS

WS

EXISTING CANOPY

TO REMAIN

AD901

AD901

AD901

AD901

AD901

AD901

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 10

BASE BID

BHA

BSS

AD203SCALE:

DEMOLITION ROOF PLAN - BUILDING 10 - BASE BID

3/32" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

61'-0" 51'-0" 61'-0"

173'-0"

'-0

'-0

'-0

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

EF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS WSWS

WS

WS

AD901

AD901

AD901

AD901

AD901

AD901

WS

EFEF

ARVARV

WS

ARV

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 3

BASE BID

BHA

BSS

AD204SCALE:

DEMOLITION ROOF PLAN - BUILDING 3 - BASE BID

1/8" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

'-0

'-0

'-0

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

EF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS WSWS

WS

WS

AD901

AD901

AD901

AD901

AD901

AD901

WS

EFEF

ARVARV

WS

ARV

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 4

BASE BID

BHA

BSS

AD205SCALE:

DEMOLITION ROOF PLAN - BUILDING 4 - BASE BID

1/8" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

179'-9"

'-0

2'-0"2'-0"

2'- 0"

2'- 0"

RIDGERIDGE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

AD901

AD901

AD901

AD901

AD901

AD901

EF

ARV

ARV

WS

WS

WS EF EF

ARV ARV

EF

ARV

WS

WS

WS WS

WS

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 5

ALTERNATE 1

BHA

BSS

AD206SCALE:

DEMOLITION ROOF PLAN - BUILDING 5 - ALTERNATE 1

1/8" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

'-0

2'-0"2'-0"

2'- 0"

2'- 0"

RIDGERIDGE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

AD901

AD901

AD901

AD901

AD901

AD901

EF

ARV

ARV

WS

WS

WS EF EF

ARV ARV

EF

ARV

WS

WS

WS WS

WS

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 6

ALTERNATE 2

BHA

BSS

AD207SCALE:

DEMOLITION ROOF PLAN - BUILDING 6 - ALTERNATE 2

1/8" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

'-0

'-0

'-0

13'-3" 6'-

8"

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARVEF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS

EF

ARVARVARVARV EFEF

WS WSWS

WS

WS

WS

EXISTING CANOPY

TO REMAIN

AD901

AD901

AD901

AD901

AD901

AD901

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 9

ALTERNATE 3

BHA

BSS

AD208SCALE:

DEMOLITION ROOF PLAN - BUILDING 9 - ALTERNATE 3

3/32" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

'-0

'-0

'-0

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

RI

DG

E

3:12 SLOPE

VALLE

YVALLEY

RIDGERIDGE

3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

EF

WS

EXIST ASPHALT

ROOF TO REMAIN

EXIST ASPHALT

ROOF TO REMAIN

WS

WS

WS WSWS

WS

WS

AD901

AD901

AD901

AD901

AD901

AD901

WS

EFEF

ARVARV

WS

ARV

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

PH

O

TO

O

R D

ET

AI

L

WS EXISTING WASTE STACK EXISTING WASTE STACK TO REMAIN. PREPARE EXISTING STACKS FOR

EXTENSION ABOVE NEW ROOF SYSTEM

EF EXISTING EXHAUST FAN REMOVE AND SALVAGE EXISTING EXHAUST FAN. STORE AND PREPARE FOR

REINSTALLATION. MECHANICAL EQUIPMENT TO BE REMOVED BY A LICENSED

MECHANICAL SUB-CONTRACTOR.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ASPHALT ROOF SYSTEM TO REMAIN, TYPICAL.

3. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED BY A QUALIFIED, LICENSED COMMERCIAL CONTRACTOR AND ELECTRICIAN. SAVE MECHANICAL EQUIPMENT FOR RE-INSTALLATION.

THE RESULTING OPENING SHALL BE COVERED AND PROTECTED. ALL ELECTRICAL ASSOCIATED WITH THE REMOVED EQUIPMENT SHALL BE PROTECTED AND PROPERLY TERMINATED, IF

REQUIRED.

4. INSPECT EXISTING ROOF AND PREP FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND STANDING METAL ROOF SYSTEM.

5. THIS BUILDING WILL BE OCCUPIED DURING RE-ROOFING. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFE INGRESS AND EGRESS TO AND FROM THE BUILDING AND OCCUPANCY WITHIN THE BUILDING. LIMIT NOISE AND DISRUPTIONS AND COORDINATE DISRUPTIVE ACTIVITIES WITH THE REPRESENTATIVES FROM THE HOSPITAL.

6. DURING THE DEMOLITION AND TEAR OFF, IF ANY OPENINGS OR PENETRATIONS THROUGH THE ORIGINAL ROOF THAT ARE TO REMAIN ARE FOUND, THESE ARE TO HAVE TEMPORARY ROOF

PATCHES INSTALLED TO PROTECT FROM MOISTURE INTRUSION.

ROOF DEMOLITION NOTESROOF DEMOLITION LEGEND

ARV EXISTING ATTIC ROOF

VENT

REMOVE EXISTING ATTIC ROOF VENT. [PREPARE EXISTING ROOF OPENING TO

RECEIVE NEW VENT AS INDICATED ELSEWHERE ON THESE DRAWINGS

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

DEMOLITION

ROOF PLAN

BUILDING 16

ALTERNATE 4

BHA

BSS

AD209SCALE:

DEMOLITION ROOF PLAN - BUILDING 16 - ALTERNATE 4

1/8" = 1'-0"

N O

R T

H

GENERAL NOTE:

SEE SHEET AD901 FOR

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

TYPICAL

REFERENCE

PHOTOS

BHA

BSS

AD901

SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS

SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS SCALE:

TYPICAL ROOF (BLDG #10)

AD901

NTS

1. PHOTOS SHOWN ARE TAKEN OF BUILDING #10. ROOF AND EQUIPMENT FOR BUILDINGS #7, #8, #9, #16, #3, #4, #5, & #6 ARE SIMILAR TO THOSE SHOWN IN THE BELOW REFERENCE PHOTOS.

EXISTING ROOF PHOTO REFERENCE NOTES

EXISTING ASPHALT ROOF

SYSTEM TO REMAIN

EXISTING ROUND

ROOF VENT, TYP.

EXISTING RECTANGULAR

ROOF VENT, TYP.

EXISTING PLUMBING

VENT STACK, TYP.

EXISTING PLASTER

FASCIA TO REMAIN

EXISTING PLUMBING

VENT STACK, TYP.

EXISTING PLASTER

FASCIA TO REMAIN

EXISTING PLUMBING

VENT STACK, TYP.

EXISTING ASPHALT ROOF

SYSTEM TO REMAIN

EXISTING ROUND

ROOF VENT, TYP.

EXISTING RECTANGULAR

ROOF VENT, TYP.

EXISTING PLUMBING

VENT STACK, TYP.

3:12 SLOPE

249'-8"

'-0

'-0

'-0

13'-3" 6'-

8"

3:12 SLOPE

3:

S

LO

PE

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

NEW STANDING

SEAM METAL ROOF

NEW STANDING

SEAM METAL ROOF

VALLEY FLASHING

RI

DG

E

CA

P

EXISTING CANOPY

TO REMAIN

RIDGE CAPRIDGE CAP

WS

EF

EF

EFEF ARVARVARVARV WS

WS

WS

WSWSWS

WS

WS

WS

A301

A301

A301

A303

A301

A302

A302

A302

A302

A302

A301

A303

A303

A301

VALLE

Y FLA

SHING

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

WS EXISTING WASTE STACK INSTALL NEW TPO BOOT AT ROOF AROUND WASTE STACK PENETRATING THROUGH ROOF.

EF EXISTING EXHAUST FAN REINSTALL SALVAGED EXISTING EXHAUST FANS BACK ONTO EXISTING SALVAGED AND MODIFIED ROOF CURB

WITH NEW STAINLESS STEEL FASTENERS.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ORIGINAL ASPHALT ROOF SYSTEM TO REMAIN. INSPECT EXISTING ROOF CONDITION FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND NEW STANDING SEAM METAL ROOF SYSTEM. NOTIFY ARCHITECT SHOULD ANY UNDESIRABLE CONDITIONS THAT

IMPACT NEW ROOFING INSTALLATION BE DISCOVERED.

3. THE EXISTING ROOFING SYSTEM ADJACENT TO ROOFTOP EQUIPMENT IS ASSUMED TO BE IN GOOD CONDITION AND ARE ASSUMED TO BE REUSABLE. THE CONTRACTOR SHALL VISUALLY OBSERVE THESE AREAS. ITEMS DEEMED TO BE IN POOR CONDITION SHALL BE REPORTED

TO THE ARCHITECT IMMEDIATELY.

4. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL MECHANICAL CONTRACTOR AND THE ELECTRICAL SERVICE SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE CODES AND SAFETY REGULATIONS. PROVIDE STRUCTURAL COMPONENTS (FASTENERS AND STRAPS) TO SECURE ALL HVAC ROOF TOP EQUIPMENT TO THE CURBS TO RESIST THE WIND LOADS INDICATED IN THE

STRUCTURAL DRAWINGS.

5. EXTEND ALL PLUMBING VENT STACKS 8" ABOVE FINISHED ROOF SYSTEM.

6. PROVIDE NEW RECTANGULAR ROOF VENTS IN SAME LOCATIONS AS PREVIOUSLY REMOVED.

ROOF RENOVATION NOTESROOF RENOVATION LEGEND

ROOF SLOPE DIRECTION NEW ROOF SLOPE DIRECTION. NEW ROOF SLOPE TO BE 1/4" PER FOOT, TYPICAL. SEE PLANS

2 / A303

5 / A303 & 6 / A303

ARV NEW ATTIC ROOF VENT PROVIDE NEW RECTANGULAR ROOF VENT IN SAME SIZE AND LOCATIONS AS PREVIOUSLY REMOVED VENTS.

PROVIDE METAL SLEEVE EXTENSIONS ON VENTS AS REQUIRED TO EXTEND VENT THROUGH EXISTING ROOF

OPENING AND INTO ATTIC SPACE.

5 / A303 & 6 / A303

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

NEW

ROOF PLAN

BUILDING 7

BASE BID

BHA

BSS

A201SCALE:

NEW ROOF PLAN - BUILDING 7 - BASE BID

3/32" = 1'-0"

N O

R T

H

249'-8"

'-0

'-0

'-0

13'-3" 6'-

8"

3:12 SLOPE

3:

S

LO

PE

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

NEW STANDING

SEAM METAL ROOF

NEW STANDING

SEAM METAL ROOF

VALLEY FLASHING

RI

DG

E

CA

P

EXISTING CANOPY

TO REMAIN

RIDGE CAPRIDGE CAP

WS

EF

EF

EFEF ARVARVARVARV WS

WS

WS

WSWSWS

WS

WS

WS

A301

A301

A301

A303

A301

A302

A302

A302

A302

A302

A301

A303

A303

A301

VALLE

Y FLA

SHING

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

WS EXISTING WASTE STACK INSTALL NEW TPO BOOT AT ROOF AROUND WASTE STACK PENETRATING THROUGH ROOF.

EF EXISTING EXHAUST FAN REINSTALL SALVAGED EXISTING EXHAUST FANS BACK ONTO EXISTING SALVAGED AND MODIFIED ROOF CURB

WITH NEW STAINLESS STEEL FASTENERS.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ORIGINAL ASPHALT ROOF SYSTEM TO REMAIN. INSPECT EXISTING ROOF CONDITION FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND NEW STANDING SEAM METAL ROOF SYSTEM. NOTIFY ARCHITECT SHOULD ANY UNDESIRABLE CONDITIONS THAT

IMPACT NEW ROOFING INSTALLATION BE DISCOVERED.

3. THE EXISTING ROOFING SYSTEM ADJACENT TO ROOFTOP EQUIPMENT IS ASSUMED TO BE IN GOOD CONDITION AND ARE ASSUMED TO BE REUSABLE. THE CONTRACTOR SHALL VISUALLY OBSERVE THESE AREAS. ITEMS DEEMED TO BE IN POOR CONDITION SHALL BE REPORTED

TO THE ARCHITECT IMMEDIATELY.

4. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL MECHANICAL CONTRACTOR AND THE ELECTRICAL SERVICE SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE CODES AND SAFETY REGULATIONS. PROVIDE STRUCTURAL COMPONENTS (FASTENERS AND STRAPS) TO SECURE ALL HVAC ROOF TOP EQUIPMENT TO THE CURBS TO RESIST THE WIND LOADS INDICATED IN THE

STRUCTURAL DRAWINGS.

5. EXTEND ALL PLUMBING VENT STACKS 8" ABOVE FINISHED ROOF SYSTEM.

6. PROVIDE NEW RECTANGULAR ROOF VENTS IN SAME LOCATIONS AS PREVIOUSLY REMOVED.

ROOF RENOVATION NOTESROOF RENOVATION LEGEND

ROOF SLOPE DIRECTION NEW ROOF SLOPE DIRECTION. NEW ROOF SLOPE TO BE 1/4" PER FOOT, TYPICAL. SEE PLANS

2 / A303

5 / A303 & 6 / A303

ARV NEW ATTIC ROOF VENT PROVIDE NEW RECTANGULAR ROOF VENT IN SAME SIZE AND LOCATIONS AS PREVIOUSLY REMOVED VENTS.

PROVIDE METAL SLEEVE EXTENSIONS ON VENTS AS REQUIRED TO EXTEND VENT THROUGH EXISTING ROOF

OPENING AND INTO ATTIC SPACE.

5 / A303 & 6 / A303

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

NEW

ROOF PLAN

BUILDING 8

BASE BID

BHA

BSS

A202SCALE:

NEW ROOF PLAN - BUILDING 8 - BASE BID

3/32" = 1'-0"

N O

R

249'-8"

'-0

'-0

'-0

13'-3" 6'-

8"

3:12 SLOPE

3:

S

LO

PE

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

ARV

NEW STANDING

SEAM METAL ROOF

NEW STANDING

SEAM METAL ROOF

VALLEY FLASHING

RI

DG

E

CA

P

EXISTING CANOPY

TO REMAIN

RIDGE CAPRIDGE CAP

WS

EF

EF

EFEF ARVARVARVARV WS

WS

WS

WSWSWS

WS

WS

WS

A301

A301

A301

A303

A301

A302

A302

A302

A302

A302

A301

A303

A303

A301

VALLE

Y FLA

SHING

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

WS EXISTING WASTE STACK INSTALL NEW TPO BOOT AT ROOF AROUND WASTE STACK PENETRATING THROUGH ROOF.

EF EXISTING EXHAUST FAN REINSTALL SALVAGED EXISTING EXHAUST FANS BACK ONTO EXISTING SALVAGED AND MODIFIED ROOF CURB

WITH NEW STAINLESS STEEL FASTENERS.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ORIGINAL ASPHALT ROOF SYSTEM TO REMAIN. INSPECT EXISTING ROOF CONDITION FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND NEW STANDING SEAM METAL ROOF SYSTEM. NOTIFY ARCHITECT SHOULD ANY UNDESIRABLE CONDITIONS THAT

IMPACT NEW ROOFING INSTALLATION BE DISCOVERED.

3. THE EXISTING ROOFING SYSTEM ADJACENT TO ROOFTOP EQUIPMENT IS ASSUMED TO BE IN GOOD CONDITION AND ARE ASSUMED TO BE REUSABLE. THE CONTRACTOR SHALL VISUALLY OBSERVE THESE AREAS. ITEMS DEEMED TO BE IN POOR CONDITION SHALL BE REPORTED

TO THE ARCHITECT IMMEDIATELY.

4. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL MECHANICAL CONTRACTOR AND THE ELECTRICAL SERVICE SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE CODES AND SAFETY REGULATIONS. PROVIDE STRUCTURAL COMPONENTS (FASTENERS AND STRAPS) TO SECURE ALL HVAC ROOF TOP EQUIPMENT TO THE CURBS TO RESIST THE WIND LOADS INDICATED IN THE

STRUCTURAL DRAWINGS.

5. EXTEND ALL PLUMBING VENT STACKS 8" ABOVE FINISHED ROOF SYSTEM.

6. PROVIDE NEW RECTANGULAR ROOF VENTS IN SAME LOCATIONS AS PREVIOUSLY REMOVED.

ROOF RENOVATION NOTESROOF RENOVATION LEGEND

ROOF SLOPE DIRECTION NEW ROOF SLOPE DIRECTION. NEW ROOF SLOPE TO BE 1/4" PER FOOT, TYPICAL. SEE PLANS

2 / A303

5 / A303 & 6 / A303

ARV NEW ATTIC ROOF VENT PROVIDE NEW RECTANGULAR ROOF VENT IN SAME SIZE AND LOCATIONS AS PREVIOUSLY REMOVED VENTS.

PROVIDE METAL SLEEVE EXTENSIONS ON VENTS AS REQUIRED TO EXTEND VENT THROUGH EXISTING ROOF

OPENING AND INTO ATTIC SPACE.

5 / A303 & 6 / A303

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

NEW

ROOF PLAN

BUILDING 10

BASE BID

BHA

BSS

A203SCALE:

NEW ROOF PLAN - BUILDING 10 - BASE BID

3/32" = 1'-0"

N O

R

A301

A301

61'-0" 51'-0" 61'-0"

173'-0"

'-0

'-0

'-0

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:12 SLOPE3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

NEW STANDING

SEAM METAL ROOF

NEW STANDING

SEAM METAL ROOF

VALLEY FLASHING

RI

DG

E

CA

P

RIDGE CAPRIDGE CAP

EF

ARV

WS

A301

A303

A301

A302

A302

A302

A302

A302

A301

A303

A303

A301

VALLE

Y FLA

SHING

ARVARVARV

EFEF

WS

WSWSWSWS

WS

WS

WS

WS

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

WS EXISTING WASTE STACK INSTALL NEW TPO BOOT AT ROOF AROUND WASTE STACK PENETRATING THROUGH ROOF.

EF EXISTING EXHAUST FAN REINSTALL SALVAGED EXISTING EXHAUST FANS BACK ONTO EXISTING SALVAGED AND MODIFIED ROOF CURB

WITH NEW STAINLESS STEEL FASTENERS.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ORIGINAL ASPHALT ROOF SYSTEM TO REMAIN. INSPECT EXISTING ROOF CONDITION FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND NEW STANDING SEAM METAL ROOF SYSTEM. NOTIFY ARCHITECT SHOULD ANY UNDESIRABLE CONDITIONS THAT

IMPACT NEW ROOFING INSTALLATION BE DISCOVERED.

3. THE EXISTING ROOFING SYSTEM ADJACENT TO ROOFTOP EQUIPMENT IS ASSUMED TO BE IN GOOD CONDITION AND ARE ASSUMED TO BE REUSABLE. THE CONTRACTOR SHALL VISUALLY OBSERVE THESE AREAS. ITEMS DEEMED TO BE IN POOR CONDITION SHALL BE REPORTED

TO THE ARCHITECT IMMEDIATELY.

4. THE EXISTING MECHANICAL EQUIPMENT SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL MECHANICAL CONTRACTOR AND THE ELECTRICAL SERVICE SHALL BE REMOVED AND REINSTALLED BY A QUALIFIED, LICENSED COMMERCIAL ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE CODES AND SAFETY REGULATIONS. PROVIDE STRUCTURAL COMPONENTS (FASTENERS AND STRAPS) TO SECURE ALL HVAC ROOF TOP EQUIPMENT TO THE CURBS TO RESIST THE WIND LOADS INDICATED IN THE

STRUCTURAL DRAWINGS.

5. EXTEND ALL PLUMBING VENT STACKS 8" ABOVE FINISHED ROOF SYSTEM.

6. PROVIDE NEW RECTANGULAR ROOF VENTS IN SAME LOCATIONS AS PREVIOUSLY REMOVED.

ROOF RENOVATION NOTESROOF RENOVATION LEGEND

ROOF SLOPE DIRECTION NEW ROOF SLOPE DIRECTION. NEW ROOF SLOPE TO BE 1/4" PER FOOT, TYPICAL. SEE PLANS

2 / A303

5 / A303 & 6 / A303

ARV NEW ATTIC ROOF VENT PROVIDE NEW RECTANGULAR ROOF VENT IN SAME SIZE AND LOCATIONS AS PREVIOUSLY REMOVED VENTS.

PROVIDE METAL SLEEVE EXTENSIONS ON VENTS AS REQUIRED TO EXTEND VENT THROUGH EXISTING ROOF

OPENING AND INTO ATTIC SPACE.

5 / A303 & 6 / A303

D.B.

JOB NO.

C.B.

DATE

BID SUBMITTAL

S

O U

T H

S T

A T

E R

O A

D

M A

C C

L E

N N

Y F

L

R E

-R O

O F

B U

IL

D

IN

G

S

N O

R T

H E

A S

T F

L O

R

ID

A S

T A

T E

H O

S P

IT

A

L

P R

O J E

C T

N U

M B

E R

09/27/2022

202212

Architect Brian

Sawyer AR0091953

License No.

1329 KINGSLEY AVE., SUITE C

ORANGE PARK, FL 32073

PH: (904) 264-1919

WWW.BHIDE-HALL.COM

LIC. NO. AAC000569

D E

S C

R

IP

T

IO

N

R E

V

IS

IO

N

S

D A

T E

S Y

M A

S U

B M

IT

T

/1

/2

B

S U

B M

IT

T

/0

/2

C B

ID

S

U B

M

IT

T

/2

/2

NEW

ROOF PLAN

BUILDING 3

BASE BID

BHA

BSS

A204SCALE:

NEW ROOF PLAN - BUILDING 3 - BASE BID

1/8" = 1'-0"

N O

R

'-0

'-0

'-0

2'-0"2'-0"

2'-0"2'-0"

2'- 0"

2'- 0"

3:12 SLOPE3:12 SLOPE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

3:

S

LO

PE

NEW STANDING

SEAM METAL ROOF

NEW STANDING

SEAM METAL ROOF

VALLEY FLASHING

RI

DG

E

CA

P

RIDGE CAPRIDGE CAP

EF

ARV

WS

A301

A301

A301

A303

A301

A302

A302

A302

A302

A302

A301

A303

A303

A301

VALLE

Y FLA

SHING

ARVARVARV

EFEF

WS

WSWSWSWS

WS

WS

WS

WS

SY

M

BO

L

O R

AB

BR

EV

IA

TI

O

N

R O

O F

C O

M

PO

N

EN

T

SC

O

PE

D

ES

C

R

IP

TI

O

N

R

EF

ER

EN

C E

WS EXISTING WASTE STACK INSTALL NEW TPO BOOT AT ROOF AROUND WASTE STACK PENETRATING THROUGH ROOF.

EF EXISTING EXHAUST FAN REINSTALL SALVAGED EXISTING EXHAUST FANS BACK ONTO EXISTING SALVAGED AND MODIFIED ROOF CURB

WITH NEW STAINLESS STEEL FASTENERS.

1. DIMENSIONS SHOWN ARE BASED ON RECORD DRAWINGS AND/OR FIELD OBSERVATIONS. FIELD VERIFY ALL DIMENSIONS.

2. EXISTING ORIGINAL ASPHALT ROOF SYSTEM TO REMAIN. INSPECT EXISTING ROOF CONDITION FOR INSTALLATION OF NEW SYNTHETIC UNDERLAYMENT AND NEW STANDING SEAM METAL ROOF SYSTEM. NOTIFY ARCHITECT SHOULD ANY UNDESIRABLE CONDITIONS THAT

IMPACT NEW ROOFING INSTALLATION…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .