D.4 Electrical Floor for Wall area updated.pdf
PDF 1 MB Posted
- Attached to
- 9905--FY24 Commercial Grade HD LED Video Wall for the Orlando VA Healthcare System, Orlando, FL.
- Solicitation number
- 36C24824Q1332
About this file
This document appears to be an electrical floor plan for a wall area associated with a federal contract opportunity. The key details are:
The document is a floor plan (Drawing H-EP1.1FA3) for Level 1, Area A, Zone 3 of a new hospital facility for the VA Medical Center in Orlando, Florida. It shows the electrical layout, including power outlets, lighting, and other electrical infrastructure. The drawing includes notes on electrical requirements such as providing separate neutral conductors, conduit routing, and electrical room locations. This floor plan is part of the documentation for a federal contract opportunity to provide a commercial grade HD LED video wall for the Orlando VA Healthcare System facilities (Solicitation #36C24824Q1332). The solicitation will be posted on or about July 25, 2024 and is set-aside for 100% service-disabled veteran-owned small business (SDVOSB) concerns. The performance period is from the date of award to the date of completion. All responses are due by August 9, 2024 at 3:00 PM EST.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| S06 36C24824Q1332 0002.pdf | ||
| D10 Interstitial Comm Maintenance Area.pdf | ||
| 36C24824Q1332 0001.pdf | ||
| D.2 Comm 1st Floor Area A2 updated.pdf | ||
| D.1 CWRR for Florida.pdf | ||
| D.5 Electrical Floor Updated.pdf | ||
| D.9 VAAR 852. 219-76.docx | DOCX document | |
| D.3 Comm 1st Floor Area Lobby Location A3 updated.pdf | ||
| D.6 Pic of Area Frame 1.jpg | JPG image | |
| S02 36C24824Q1332.pdf | ||
| D.8 Panel Schedule.png | PNG image | |
| D.7 Pic of Area Frame 2.jpg | JPG image |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
E PP
PP
E
E
E
E E
PP
E
PP
E
E
E
E
E
PP
PP
E
E
E
J E J
J E
E J
J
J
J
J
JCB
C26 C27 C28
CC
CD
CE
CF
CG
CH
CJ
CK
D27
1CC01
CORR
1E902
TOILETS
1E901E
TOILETS
1E901A
STAFF
LOCKERS
1E901
VEST
1E901B
SHWR
1E901C
SHWR
1E905
WORK 1E907
GUEST
SHOWER
1E402
WAITING
1E402E
VA BILLING
1E402D
VA BILLING
1E402C
NON-VA
BILLING
1E402B
ROI
1E402A
ROI
1E106C
PNT
ADVOCATE
1E106B
PNT
ADVOCATE
1E106A
PNT
ADVOCATE
1E106
WAITING
1EC02
CORR
1E202
STORAGE
1EC02A
CORR
1EC01
CORR
1ES01
STAIR
1AST3
1EC04
CORR-1
1EC04
CORR-2
1E101
LOBBY
1E111
ELEV.LOBBY
1EE03
ELEV CP 3
TR
TR
TR
TR
TR
G
G
OC
OC
OC/G
OC/G
OC/G
OC/G
OC/G
OC
OC/G
OC/G
OC/G
OC
OC
OC
OC
OC
OC
G
MV/G
OC/G
TV
TV
TV
TV
TR
TR
TR
RE
F
LI
NE
H-
EP
1.
1F
A2
REF LINE
H-EP1.1FC1
D29
D26
D25 D24 DJ
DJ
DH
DH
DG
DF
DF
DE
DD
DD
DB
D28
TR
TR
TR
TR
TR
TV
TV
TV
TR
TR
TR
TV
OC
OC
OC
OC
OC
OC
OC
OC
MV/G
OC
OC/G
G
OC/G
OC/G
OC/G
OC/G
OC/G
C1B1LN1-22
C1B1LN1-24
C1B1LN1-23
C1B1LN1-26
C1B1LN1-27
C1B1LN1-28
C1B1LN1-29
C1B1LN1-30
C1B1LN1-31
C1B1LN1-32
C1B1LN1-33
C1B1LN1-34
C1B1LN1-35
C1B1LN2-1
C1B1LN2-2
C1B1LN2-3
C1B1LN2-4
C1B1LN2-5
C1B1LN2-6
C1B1LN2-8
C1B1LN2-10
C1B1LN2-11
C1B1LN2-12
C1B1LN2-13
C1B1LN2-14
C1B1LC1-1
C1B1LS1-11
CE54
C1B1LC1-4
CE25
CE1
C1B1LN2-17
CE55
C1B1LC1-16
CE66 CE66
C1B1LC1-18
C1B1LC1-19 C1B1LC1-20
DCC1B1LN2-32
C1B1LN2-31
TR
OC/G
G +48"
C1A2LN9-14
C1A2LN9-16
C1A2LN9-18
C1A2LN9-20
C1A2LN9-21
C1A2LN9-22
TR
MV/G
TR
TR
C1A2LN9-31
C1A2LC3-1
C1A2LN9-32
C1A2LN10-3
C1A2LN10-1
C1A2LN10-4
C1A2LN10-5
C1A2LN9-24
C1A2LN11-3
C1A2LC3-2
C1A2LN9-23
C1A2LN10-9
C1A2LN10-11
C1A2LN11-4
C1A2LN10-13
C1A2LN10-14
C1A2LN10-15
C1A2LN10-16
C1B1LN2-15
C1A2LN10-2
C1A2LN10-23
C1A2LN10-24
C1A2LN10-29
C1 A2
LN
-1
CE54
C1A2LS1-22
1E915
VEST
1E915A
STAFF
LOCKERS
1E915B
LACT RM
1E915C
SHWR
1E915E
TOILETS
1E116
TOILETS-1
1E114
TEAM
1E401A
SEAMLESS
CM
1E401
WAITING 1E401B
MAS
INTERVIEW
1E401C
MAS
INTERVIEW
1E401D
MAS
INTERVIEW
1E401E
MAS
INTERVIEW
1E401F
MAS
INTERVIEW
1E401G
MAS
INTERVIEW
1E401H
MAS
SUPER
1E401J
MAS
SUPERVISOR
1E114
TEAM
1EC09
CORRIDOR
CE1
CE1
C1A2LC3-9
C1A2LC3-10
CE25
C1A2LC3-6
1CC09
CORR
REF LINE
H-EP1.1FB1
TR
TR
C1A2LN11-1
C1A2LN11-2
C1A2LN10-22
1EC01A
Space
CE55
C1A2LC3-11
C1A2LC3-12
CE54
C1 A2
LS
1-
CE70
C1A2LS1-30
CE70
C1A2LS1-31
C1A2LN10-12
CE73
CE73
CE73
C1A2LS2-2
C1B1LS1-28C1B1LS1-294
3 3
C1B1LN2-29
CE80
14-50R
C1A2LN11-23
C1A2LN11-6,8
13006
SS
SS
TR
TR
EX
EX
C1A2LN10-36
OC/G
C1A2LN10-37
OC/G
C1A2LN9-35
C1B1LN2-34
C1B1LN2-35
AD L
EK
N
LL
E F
S
R P
O
IS EN
L
GI
O N A
E E
N R
EC NIL
S E
No 0052705
STATE OF
ROLF
I D A
EE
AS
M
ON
N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot 6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Department of Veterans Affairs
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
NOTES:
SHEET NOTES:
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'0
KEY PLAN
A1
C2
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
LEVEL 1, AREA A , ZONE 3
01 AND 02
Professional Seals:
P2 P3P1 P4
CLINIC
HOSPITAL
A4
E4
D7 W
432204 JUNE, 2010 KLM EB/RLF
HOSPITAL/CLINIC
H-EP1.1FA3
LEVEL 1, AREA A, ZONE 3 POWER PLAN
1 SEE SHEET H-EP1.1FA2 FOR CONTINUATION.
2 PROVIDE 3/4" EMPTY CONDUIT WITH PULL STRING FOR
AUTOMATIC DOOR CONTROL WIRING.
3 PROVIDE 4" SQUARE X 2-1/8" DEEP BOX WITH TWO-GANG
PLASTER RING FOR POCKET FIRE DOOR KEY OPERATED
SWITCH. FLUSH MOUNT IN WALL AT 48" AFF TO CENTER. KEY
SWITCH IS PROVIDED WITH FIRE DOOR.
4 PROVIDE 3/4" CONDUIT FOR FIRE DOOR KEY SWITCH
CONTROL WIRING.
5 CONNECT TO UNDERCABINET LIGHTING IN THIS ROOM.
6 DEDICATED RECEPTACLE FOR USE WITH COFFEE MAKER.
7 PROVIDE BACKBOX AS REQUIRED FOR SINGLE DOOR DISPLAY
PER MANUFACTURERES REQUIREMENTS. MOUNT BOX AT
+60" AFF TO BOTTOM.
8 3/4" CONDUIT FOR SINGLE DOOR DISPLAY LOW VOLTAGE
WIRING.
9 PROVIDE BACKBOX AS REQUIRED FOR OBSTRUCTION
DETECTOR PER MANUFACTURER REQUIREMENTS. MOUNT AT
18" AFF TO TOP.
10 3/4" CONDUIT FOR OBSTRUCTION SENSOR LOW VOLTAGE
WIRING.
KEY NOTES:
A PROVIDE A SEPARATE NEUTRAL FOR EACH 120V
CIRCUIT.
SHARING OF NEUTRAL CONDUCTORS IS NOT ALLOWED.
B 120V, 20A SINGLE PHASE CIRCUITS ORIGINATING FROM THE SAME
PANELBOARD MAY BE COMBINED INTO A SINGLE 3/4" CONDUIT
HOMERUN WITH A MAXIMUM OF 3 CIRCUITS IN ANY CONDUIT.
C ALL HOMERUNS SHALL BE ROUTED FROM THE DEVICE OR
FIXTURE INDICATED UP TO THE BRANCH CONDUIT RACK LOCATED
IN THE "S4" ZONE OF INTERSTITIAL SPACE. EXTEND CONDUIT
ALONG THE RACK IN THE "S4" ZONE AND THEN TRANSITION UP
THE MAIN DISTRIBUTION RACKS LOCATED IN THE "S3" ZONE OF
INTERSTITIAL SPACE. EXTEND THE CONDUIT ALONG THE MAIN
DISTRIBUTION RACKS IN THE "S3" ZONE TO THE PANELBOARD
LOCATED IN THE ELECTRICAL ROOM. SEE 1/H-EP5.510 FOR
INTERSTITIAL FLOOR PENETRATION DETAIL. SEE SHEET
H-EP5.504 FOR INTERSTITIAL SPACE CONDUIT RACK DETAILS.
No. Description Date
1 CPR 058 04/15/2011
2 CPR 278 05/04/2012
3 CPR 407 08/02/2013
4 CPR 416 04/25/2014
Video Wall Location
VHAORLVOHSJ
Highlight
VHAORLEdwarR Highlight
VHAORLEdwarR Highlight
VHAORLEdwarR Highlight
File details come from the government source that posted it. Updated .