D-1 M0068122Q0016 Solicitation - Description.pdf

PDF 1 MB Posted

Attached to
Dismantle And Remove A Government Owned Custom Conveyor System
Solicitation number
M0068122Q0016
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Conveyor System Description

The system was custom designed to support the storage operations in building 2251.

Length: Estimated 1,580’ , some of which is above existing offices.

Design: Full loop. Floor level conveyor is 30” H , the empty tote return line is 72” H and the upper level is 9’ H.

*Note that 90+% of the system is upper level that has floor supports and ceiling hangers.

Guard Rail: Adjustable channel is on all elevated conveyor and angle is on the floor level conveyor.

Rollers: 16” with 17” between frames, 3” on center spacing

Operation: Both powered belt driven rollers and non-powered rollers to include skate wheels

Other Components: Photo eyes, diverts, spurs, full line sensors, motors, emergency stops, bar code scanners and air compressors with dryers.

Control Panels: Allen Bradley programmable Logic Controller ( PLC ) and NEMA enclosure.

Legend for Photos (page-description):

1. Receiving: In bound powered conveyor

2. Receiving: Front - out bound Back - in bound

3. Receiving: Out / In bound

4. Receiving: Front - Out bound Back - in bound

5. Receiving: Out bound

6. Receiving: Front - out bound Back - in bound

7. Receiving: Out bound to storage area

8. Shipping: In bound with empty tote return lane

9. Shipping: In bound with empty tote return lane 10.Shipping: In bound from storage area 11.Storage Area:

Out bound to shipping 12.Storage Area: Left - In bound Right- Out bound to shipping 13.Storage Area: Left -in bound with diverts/ spurs Right- Out bound to shipping

14. Storage Area: Left - out bound to shipping Right- In bound with diverts/spurs

15. Control Panel

16. Storage Rack Area: in bound 17.Storage Rack Area: in bound 18.Air Compressors with dryers 19.Air Compressor ID Plate

File details come from the government source that posted it. Updated .