CVSP_Prelim_Plans.pdf

PDF 2 MB Posted

Attached to
FPCM-SW-HCFIP-001-ML Pharmacy Casework
Solicitation number
0000000154
Issued by
California

About this file

This document appears to be a preliminary equipment and furniture plan for the Central Health Services area of the Chuckawalla Valley State Prison. It is being developed by the California Department of Corrections and Rehabilitation (CDCR). The plan details over 100 individual medical, healthcare, and general equipment and furniture items to be provided and installed, including waste receptacles, exam equipment, computers, desks, chairs, and more. The plan provides item descriptions, quantities, and locations within the Central Health Services area. This appears to be an early-stage planning document, as it is labeled "Preliminary (50% WDs)".

The document does not provide information on pricing, set-asides, incumbents, funding sources, or other commercial terms. It appears focused solely on detailing the equipment and furnishings required for the Central Health Services area of the prison facility.

View the file

Other files

File Type Posted
CIM_Plans.pdf PDF
RJD_Plans.pdf PDF
SW-HCFIP-001-ML_Pharmacy_Casework.pdf PDF
CCWF_Plans.pdf PDF
CIW_Plans.pdf PDF
KVSP_Plans.pdf PDF
VSP_Plans.pdf PDF
CEN_Prelim_Plans.pdf PDF
Healthcare_Casework_Specification_Rev_01.pdf PDF
ISP_Prelim_Plans.pdf PDF
SOL_Plans.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U124633603

WASTE RECEPTACLE

U124633604

WASTE RECEPTACLE - BIO

M-U117000124-B

DISPENSER, GLOVE

M-U117000117-b

ENCLOSURE, SHARPS

M-U117200611-B

STAND, MAYO

M-U117000664-A

CART, PROCEDURE

O112800104

COMPUTER BRACKET

M-U117000683

UTILITY TABLE

M-U117200613

ASPIRATOR

M-U117000633-c

OXYGEN TANK CART

U112800601-a

COMPUTER

M-U117200603

STOOL, REVOLVING

M-U117200120

INTEGRATED WALL SYSTEM

M-U117000620

OXYGEN TANK BRACKET

C105623102

WIRE SHELVING

U112800601-a

COMPUTER

U112800602

LASER PRINTER

U125100709

CHAIR

M-U117000127

REFRIGERATOR

M-U117000185

FREEZER

U112800602

LASER PRINTER

U105623601-A

WIRE CART

U112800601-a

COMPUTER

U124633602

WASTE RECEPTACLE

U125100709

CHAIR

U112800602

LASER PRINTER

U112800601-a

COMPUTER

U125100709

CHAIR

M-U117200601-B

CART, CRASH

U112800601-a

COMPUTER

M-U117200611-A

STAND, MAYOM-U117200604

LIGHT, EXAM, MOBILE

M-U117000670

EXCHANGE CART

C105623102

WIRE SHELVING

U113100601-B

WASTE RECEPTACLE

U117000403

DISPENSING UNIT, MEDICATION

M-U117000139

REFRIGERATOR, UNDERCOUNTER

U124633602

WASTE RECEPTACLE

U125100616

DESK

U125100709

CHAIR

U124633602

WASTE RECEPTACLE

U124633607

WASTE RECEPTACLE ROLLOUT- BIO

M-U117000114

NARC CABINET

U125119612

PEDESTAL, MOBILE

U124633602

WASTE RECEPTACLE

U124633602

WASTE RECEPTACLE

U112800601-a

COMPUTER

e5 e5 e6 e6 e7 e7 e8 e8 e8.1 e8.1 e9 e9 eAeA eBeB

U125100662

BOOKCASE

OBSERVATION

E124B

(E) DENTAL

SUPPLY

(E) DENTAL

LAB

STANDARD

BAY

E124A

URGENT

BAY

E124C

NURSING

WORKROOM

E125

TTA

HALLWAY

E124

MEDICATION

STORAGE

E125A

CLEAN

UTILITY

E129

OXYGEN

STORAGE

E130A

MENTAL

HEALTH

E127

MEN

TOILET

E133

LABORATORY

E131

(E)

BREAKROOM

E191

(E) UM

NURSE

(E) UM

NURSE

(E) CLEAN

UTILITY

(E)

MEDICAL

STORAGE

(E) CLEAN

LINEN

(E)

SUB-UTIL

(E)

JANITOR

(E) CELL

(E) CELL

(E) INMATE

TOILET

E135

(E)

PHARMACY

E134

CHIEF

PSYCHOLOGIST

OFFICE

E140

STOR.

BREAK

ROOM

E139

(E)

NARCOTICS

E138

(E)

STORAGE

E137

(E)

PHYSICAL

THERAPY

(E) OFFICE/

STORAGE

(E)

RADIOLOGY

SOILED

UTILITY

E126

U125100662

BOOKCASE

U112800602

LASER PRINTER

U124633602

WASTE RECEPTACLE

U125100642

CHAIR

U125100701

CHAIR

O111900444-a

BOOTH

M-U117200113

SCALE, WHEELCHAIR

U125100617

DESK L/H

P.I.C.

OFFICE

E136

U125100709

CHAIR

C101100111

BULLETIN CABINET

M-U117000124-B

DISPENSER, GLOVE

M-U117000117-b

ENCLOSURE, SHARPS

U124633604

WASTE RECEPTACLE - BIO

U124633603

WASTE RECEPTACLE

M-U117000162

FLOOR CABINET

M-U117000128

REFRIGERATOR

M-U117000128

REFRIGERATOR

M-U117000185

FREEZER

U112800601-a

COMPUTER

U124633602

WASTE RECEPTACLE

C105623102

WIRE SHELVING

M-U117000185

FREEZER

U124633602

WASTE RECEPTACLE

U125100709

CHAIR

F2.1.2E7

F2.1.2E 1

F2.1.2E4

U112800602

LASER PRINTER

U125100617

DESK L/H

U125100709

CHAIR

U112800601-a

COMPUTER

U124633602

WASTE RECEPTACLE

DUAL

FILLING

STATIONS

SHIPPING/

RECIEVING

DATA

ENTRY

EQUIPMENT AND FURNITURE LIST LEGEND

ITEM NUMBER SUPPLIER/INSTALLER

C XXXXXXXXX CONTRACTOR-FURNISHED, CONTRACTOR-INSTALLED

O XXXXXXXXX OWNER-FURNISHED, CONTRACTOR-INSTALLED

U XXXXXXXXX OWNER-FURNISHED, OWNER-INSTALLED

M-C XXXXXXXXX MEDICAL/HEALTHCARE, CONTRACTOR-FURNISHED, CONTRACTOR-INSTALLED

M-O XXXXXXXXX MEDICAL/HEALTHCARE, OWNER-FURNISHED, CONTRACTOR-INSTALLED

M-U XXXXXXXXX MEDICAL/HEALTHCARE, OWNER-FURNISHED, OWNER-INSTALLED

KEY TO ITEM NUMBER

C 111900 407 -a

SUPPLIER/INSTALLER, SEE LEGEND ABOVE

CSI SECTION WHERE SPECIFIED

IDENTIFYING NUMBER

SUB-LETTER, AS REQUIRED

M-C 117200 110-b

SUPPLIER/INSTALLER, SEE LEGEND ABOVE

CSI SECTION WHERE SPECIFIED

IDENTIFYING NUMBER

SUB-LETTER, AS REQUIRED

2' - 8"2' - 9"2' - 9" 2' - 0" 2' - 0"

4' - 6"

2' - 11" 4' - 0" 2' - 0 1/2"

1' - 11" 3' - 0" 3' - 0" 2' - 0"

3' - 0"3' - 1"2' - 1 1/2"

3' - 0" 3' - 0" 2' - 2" 2' - 1 1/2" 2' - 4" 2' - 6" 2' - 1 1/2"

STORAGE AREA

AT-5

2149770.78

6970312.31

460.43

AT-9

2151452.44

6971432.38

454.33

AT-3

2151620.79

6969006.03

450.12

OPEN STORAGE

OP

EN

S

TO

RA

GE

OP

EN

S

TO

RA

GE

OP

EN

S

TO

RA

GE

OP

EN

S

TO

RA

GE

PIPE

PLAYGROUND

GYM EQU

IP.

OPEN STORAGE

TANK

TANK TANK

ANTENNAANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

SIGN

POLE

POLE

POLE

POLE

POLE

POLEPOLE

POLE

POLE

POLE POLE

POLE

FPFP

SP

SP

A I

N R

O F

I L

A C

A K

E R

U E

OF

T H

E

S

TA T E

L A

E S

T

A

E RG E HT

F O

CALIFORNIA STATE FIRE MARSHAL

APPROVED

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspections. One set of approved plans shall be available on the project site at all times.

Reviewed by:

Construction Management, Inc.

9838 Old Placerville Road, Suite A Sacramento, Ca 95827

(916) 575-8888

JOB NO.

DATE

DESTROY AFTER USE

SHEET TITLE:

SHEET

L A

S T

R E

V

IS

IO

N

C A

L

IF

O R

N

IA

D E

P A

R T

M E

N T

O F

C O

R R

E C

T

IO

N S

A N

D R

E H

A B

IL

IT

A T

IO

N

REVISIONS

NO. DATE

Reviewed by:

DEPARTMENT OF CORRECTIONS

ACCESS COMPLIANCE REVIEW

Approval of this plan does not authorize or approve any ommission or deviation from applicable regulations

OSHPD PEER REVIEW APPROVED

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspection. One set of approved plans shall be available on the project site at all times.

Reviewed by:

OFFICIAL STAMP

KEY PLAN

o n e e ig h th i n c h o n e f o o t th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

OFFICIAL STAMP

CONSULTANT LOGO

ARCHITECT LOGO

/3

/2

:4

:5

A

M

C:\Users\nheung\Desktop\Local Revit Files\CDCR_2015\26_oooo_Fo_CEN.rvt

F2.1.2E12/02/2015

SP2 - FURNITURE,

FIXTURE &

EQUIPMENT PLAN

AREA B - CENTRAL

HEALTH SERVICES

C H

U C

K A

W A

L L A

V A

L L E

Y S

T A

T E

P R

IS

O

N

W

IL

E

Y W

E L L R

O A

D B

L Y

T H

E C

A

C D

C R

H

C F

IP

1/4" = 1'-0"F2.1.2E

8 FURNITURE, FIXTURE & EQUIPMENT PLAN - CENTRAL HEALTH SERVICES AREA B

SP2 EQUIPMENT AND FURNITURE SCHEDULE

Count EQ# Description

5 C105623102 WIRE SHELVING

1 M-U117000114 NARC CABINET

6 M-U117000117-b ENCLOSURE, SHARPS

7 M-U117000124-B DISPENSER, GLOVE

1 M-U117000127 REFRIGERATOR

1 M-U117000139 REFRIGERATOR, UNDERCOUNTER

1 M-U117000144-A PEDESTAL BASE

1 M-U117000185 FREEZER

3 M-U117000610-B STRETCHER

1 M-U117000620 OXYGEN TANK BRACKET

3 M-U117000633-c OXYGEN TANK CART

6 M-U117000664-A CART, PROCEDURE

1 M-U117000670 EXCHANGE CART

3 M-U117000683 UTILITY TABLE

1 M-U117200113 SCALE, WHEELCHAIR

3 M-U117200116-a TABLE, EXAM, ADULT

6 M-U117200120 INTEGRATED WALL SYSTEM

1 M-U117200601-B CART, CRASH

6 M-U117200603 STOOL, REVOLVING

1 M-U117200604 LIGHT, EXAM, MOBILE

1 M-U117200611-A STAND, MAYO

3 M-U117200611-B STAND, MAYO

3 M-U117200613 ASPIRATOR

1 M-U117200686-C TELEMEDICINE STATION

1 O111900444-a BOOTH

6 O112800104 COMPUTER BRACKET

1 U105623601-A WIRE CART

21 U112800601-a COMPUTER

6 U112800602 LASER PRINTER

1 U113100601-B WASTE RECEPTACLE

1 U117000403 DISPENSING UNIT, MEDICATION

20 U124633602 WASTE RECEPTACLE

7 U124633603 WASTE RECEPTACLE

7 U124633604 WASTE RECEPTACLE - BIO

2 U124633607 WASTE RECEPTACLE ROLLOUT- BIO

1 U125100616 DESK

2 U125100617

1 U125100641 CHAIR

2 U125100642 CHAIR

3 U125100662 BOOKCASE

1 U125100674 CHAIR

1 U125100701 CHAIR

11 U125100709 CHAIR

5 U125119612 PEDESTAL, MOBILE

1/4" = 1'-0"F2.1.2E

1 DATA ENTRY EAST

1/4" = 1'-0"F2.1.2E

2 DUAL FILLING STATION EAST

1/4" = 1'-0"F2.1.2E

3 DUAL FILLING STATION SOUTH

1/4" = 1'-0"F2.1.2E

4 DUAL FILLING STATION WEST

1/4" = 1'-0"F2.1.2E

5 SHIPPING NORTH

1/4" = 1'-0"F2.1.2E

6 SHIPPING SOUTH

1/4" = 1'-0"F2.1.2E

7 SHIPPING WEST

PRELIMINARY (50% WDs) jglasman Text Box Note: The floorplans do not quite accurately reflect plans for the Pharmacy staff locations. Specifically, there should be three data entry staff in area 121. Details below left are the best reference.

H

G

H

H

H

H H

HH

G

SS S

M

M

M

M

M1 M1

MMM1

M1

M1

M1

M1

M M

M

M

M1

M

M1 M

J

(E)

DENTAL

LAB

(E)

DENTAL

SUPPLY

OBSERVATION

E124B

TTA

HALLWAY

E124

CLEAN

UTILITY

E129

CORRIDOR

E128

OXYGEN

STORAGE

E130A

(E) UM

NURSE

(E)

CLEAN

UTILITY

(E)

PHARMACY

E134

(E)

PHYSICAL

THERAPY

(E)

RADIOLOGY

(E)

CLEAN

LINEN

(E)

OFFICE/

STORAGE

CHIEF

PSYCHOLOGIST

OFFICE

E140

STOR.

BREAK

ROOM

E139

(E)

NARCOTICS

E138

(E)

STORAGE

E137

STANDARD

BAY

E124A

URGENT

BAY

E124C

NURSING

WORKROOM

E125

SOILED

UTILITY

E126

MENTAL

HEALTH

E127

MEN

TOILET

E133

(E)

CORRIDOR

E121

MEDICATION

STORAGE

E125A

(E)

INMATE

TOILET

E135

(E) CELL

(E) CELL

(E)

JANITOR

LABORATORY

E131

(E)

BREAKROOM

E191

(E)

SUB-UTIL

(E)

MEDICAL

STORAGE

(E) UM

NURSE

e5 e5 e6 e6 e7 e7 e8 e8 e8.1 e8.1 e9 e9 eAeA eBeB

ES

2 .

2.

1E

STORAGE AREA

AT-5

2149770.78 6970312.31

460.43

AT-9

2151452.44 6971432.38

454.33

AT-3

2151620.79 6969006.03

450.12

OPEN STORAGE

OP

EN

ST

OR

AG

E

OP

EN

STO

RA

GE

OP

EN

STO

RA

GE

OP

EN

STO

RA

GE

PIPE

PLAYGROUND

GYM EQUIP

OPEN STORAGE

TANK

TANK TANK

ANTENNAANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

ANTENNA

SIGN

POLE

POLE

POLE

POLE

POLE

POLEPOLE

POLE

POLE

POLE POLE

POLE

FPFP

SP

SP

N

AI

N

R O

F I

L A

C

A K

E R

U E

OF

T H

E

STA T E

L A

E S

T A E RG E HT

F O

CALIFORNIA STATE FIRE MARSHAL

APPROVED

Approval of this plan does not authorize or approve any omission or deviation from applicable regulations. Final approval is subject to field inspections. One set of approved plans shall be available on the project site at all times.

Reviewed by:

Construction Management, Inc.

9838 Old Placerville Road, Suite A Sacramento, Ca 95827

(916) 575-8888

JOB NO.

DATE

DESTROY AFTER USE

SHEET TITLE:

SHEET

LA

ST

R

EV

IS

IO

N

C

AL

IF

O

R N

IA

D

EP

AR

TM

EN

T O

F C

O R

R

EC

TI

O

N S

AN

D

R

EH

AB

IL

IT

AT

IO

N

REVISIONS

NO. DATE

Reviewed by:

DEPARTMENT OF CORRECTIONS

ACCESS COMPLIANCE REVIEW

Approval of this plan does not authorize or approve any ommission or deviation from applicable regulations

KEY PLAN

on e ei gh th in ch o ne fo ot th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

SP-2 CENTRAL HEALTH

Capital Expenditure Managers 2750 Gateway Oaks Drive Suite 300 Sacramento, CA 95833

(916) 648-9700

/3

0/

1:

:0

AM

C:\BIM\26_oooo_MEP_CEN_asalija.rvt

ES2.2.2E

3593-001-00

SP2 - CENTRAL HEALTH

SERVICES - EQ COORD

CHECK - POWER & SIGNAL -

AREA B

W

IL

EY

W

EL

L R

O

AD

BL

YT

H E, C A

C D

C R

H

C

FI

P

12/02/2015

C H

U C

KA

W

AL

LA

V

AL

LE

Y

ST

AT

E

PR

IS

O

N

1/4" = 1'-0" 1 SP2 - CENTRAL HEALTH SERVICES - EQ COORD CHECK - POWER & SIGNAL - AREA B N0 2'-0" 4'-0" 8'-0"

NOT FOR

CONSTRUCTION

PRELIMINARY (50% WDs) jglasman Text Box See note on sheet F2.1.2E.

General
G0.0
G0.1
G0.2
G1.0
G2.1.0A
G2.1.1A
G2.2.0A
G2.2.1A
G2.3.1A
G2.1.0B
G2.1.1B
G2.2.0B
G2.2.1B
G2.3.1B
G2.1.0E
G2.1.1E
G2.2.0E
G2.2.1E
G2.3.0E
G2.3.1E
G2.4.0E
G2.4.1E
G2.1.1F
G3.0
G3.0A
G3.0B
G3.0C
G3.0D
G3.0E
G3.0F
Hazardous Materials
H2.0
H2.0A
H2.0B
H2.0.1E
H2.0.2E
Civil
C0.01
C1.00
C1.01
C1.02
C1.03
C1.04
C1.05
C1.06
C1.10
C1.20
C1.21
C1.30
C1.31
C1.32
C1.33
C1.34
C1.35
C1.36
C1.40
C1.50
C1.51
C1.52
C1.53
C1.54
C1.55
C1.56
C1.57
C5.00
C5.01
C5.02
C5.03
C5.04
Architectural
A1.0
A1.1
A1.20
A1.21
A1.22
A1.23
A1.24
A1.25
A1.30
A1.31
A1.32
A2.0A
A2.1A
A2.2A
A2.3A
A3.1A
A4.1A
A5.1A
A7.1A
A9.1A
F2.1A
F3.1
A2.0B
A2.1B
A2.2B
A2.3B
A3.1B
A4.1B
A5.1B
A7.1B
A9.1B
F2.1B
F3.1
A2.0.0E
A2.0.1E
A2.0.2E
A2.1.0E
A2.1.1E
A2.1.2E
A2.3.1E
A2.3.2E
A3.1E
A7.1E
A9.0E
A9.1.1E
A9.1.2E
F2.1.1E
F2.1.2E
F3.1
A2.1F
A2.2F
A2.3F
A3.1F
A4.1F
A5.1F
A7.1F
A9.1F
F2.1F
F3.1
A6.1
A6.2
A6.3
A6.4
A6.5
A8.1
A8.2
A8.3
A8.4
A8.5
A8.6
A8.7
A8.8
A8.9
A8.10
A8.12
A8.13
A8.14
Structural
S0.0.1
S0.0.2
S1.1.1
S1.1.2
S1.2.1
S1.2.2
S1.3.1
S1.4.1
S1.6.1
S1.6.2
S2.1A
S2.2A
S2.1B
S2.2B
S2.1.0E
S2.1.1E
S2.1.2E
S2.1F
S2.2F
S6.1
S6.2
Mechanical
M0.1.1
M2.0A
M2.0B
M2.0.1E
M2.0.2E
M2.1A
M2.1B
M2.1.1E
M2.1.2E
M2.2A
M2.2B
M2.2.1E
M2.2.2E
M2.2F
M2.5A
M2.5B
M2.5.1E
M2.5.2E
M2.5F
M3.0
M6.0
Plumbing
P0.1.1
P2.0A
P2.0B
P2.0.1E
P2.0.2E
P2.2A
P2.2B
P2.2.1E
P2.2.2E
P2.2F
P2.5A
P2.5B
P2.5.1E
P2.5.2.E
P2.5F
P6.0
Electrical
E0.1.1
E1.0F
E2.0A
E2.0B
E2.0.1E
E2.0.2E
E2.1A
E2.1B
E2.1.1E
E2.1.2E
E2.1F
E2.2A
E2.2B
E2.2.1E
E2.2.2E
E2.2F
E2.3A
E2.3B
E2.3F
E3.0
E3.1
E3.2E
E3.3F
Fire Protection
FP0.1.1
FP2.0A
FP2.0B
FP2.0.1E
FP2.0.2E
FP2.2A
FP2.2B
FP2.2.1E
FP2.2.2E
FP2.2F
FP6.0
Security and Communications
SC0.1.1
SC1.0
SC2.1A
SC2.1B
SC2.1.1E
SC2.1.2E
SC2.1F
SC2.2A
SC2.2B
SC2.2.1E
SC2.2.2E
SC2.2F
SC3.1

File details come from the government source that posted it. Updated .