CSD - PV - Bid Set Drawings 02-22-22.pdf
PDF 1 MB Posted
- Attached to
- Roof Replacement and Repair Project - #22330-02: Pleasant Valley Elementary, Butler Creek Elementary
- Solicitation number
- S-P26028-00002320
- Issued by
- Multnomah County, Oregon
About this file
This document contains the bid specifications and drawing package for a roof replacement and repair project at Pleasant Valley Elementary and Butler Creek Elementary schools in Multnomah County, Oregon. The project involves the replacement of roofing assemblies at select roof areas, including the removal and disposal of existing roofing materials, installation of new underlayment, insulation, coverboard, and modified bituminous roofing. Alternates are included for additional roof area replacements. Contractors are required to conduct mock-ups and testing prior to installation. The project is being solicited by the Centennial School District, with a bid set date of February 22, 2022.
The bid package provides detailed scopes of work, material specifications, and installation requirements. Pricing is lump sum for the base bid and alternates. Funding for the project is provided by the school district. No set-aside requirements are mentioned. The incumbent contractor is not identified. The project duration and any renewal options are not specified in the provided documents.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CSD PV - Butler Creek 2022 Specification Manual.pdf | ||
| REQUEST FOR QUALIFICATIONS- McKay Creek Analysis.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT SUMMARY,
GENERAL NOTES
+SITE PLAN
A0.1
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
DISTRICT
PROJECT
A0.1 GENERAL NOTES AND SITE PLAN
A0.2 ROOF TYPES
A1.1 BASE SCOPE : ROOF AREAS A, A1 + A2
A1.2 ALT #1 : ROOF AREAS S2
ALT #2 : ROOF AREA S6
ALT #3 : ROOF AREA B
W1.1 WEATHERIZATION DETAILS
W1.2 WEATHERIZATION DETAILS
W1.3 WEATHERIZATION DETAILS
W1.4 WEATHERIZATION DETAILS
GENERAL SCOPE:
ROOF REPLACEMENT AT SELECTED ROOF
AREAS.
YEAR BUILT: 1940
NO. OF BUILDINGS: 2
OCCUPANCY: VARIES
CONSTRUCTION TYPE: VARIES
CODE: 2019 OSSC (2018 OBC W/ OREGON
AMENDMENTS
ADDRESS: 17625 SE FOSTER RD,
GRESHAM, OR 97080
OWNER: CENTENNIAL SCHOOL DISTRICT
18135 SE BROOKLYN ST.
PORTLAND, OR 97236
CONTRACTOR: TBD
CONSULTANT: J2 BUILDING CONSULTANTS, INC
4504 S CORBETT AVE.
PORTLAND, OR. 97239
PROJECT DESCRIPTION GENERAL NOTES
INDEX TO DRAWINGS PROJECT TEAM
SCALE :A0.1
1 SITE VICINITY MAP
NTS
NORTH
SCALE :A0.1
2 SITE PLAN
NTS
NORTH
SUBJECT SITE
S3
S4
A
S2
S1
A2
S6
A1
R1
R2
R2
R1
R1
GENERAL;
ROOF PLANS ARE CONCEPTUAL AND FOR DIAGRAMMATIC
PURPOSES ONLY. DO NOT SCALE DRAWINGS. CONTRACTOR
TO VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS.
MATCH EXISTING CONDITIONS EXCEPT AS NOTED.
KEY:
= NOT INCLUDED IN SCOPE OF WORK
= ALTERNATES : REPAIR SCOPE NOT
INCLUDED IN THESE DOCUMENTS, REFER TO
THE SEPARATE PHOTO APPENDIX FOR
SCOPE OF WORK
= REFER TO THE RESPECTIVE PLANS AND
DETAILS FOR REPAIR SCOPE
RX
= ROOF TYPES SHEET A0.3
= "ROOF AREA" DESIGNATION
S5
NOTES:
1. PROVIDE EXTERIOR PRODUCT SUBMITTALS FOR REVIEW BY J2 PRIOR TO INSTALLATION.
2. WATER TESTING MAY BE REQUIRED BY CONSULTANT.
GENERAL CONSTRUCTION NOTES
1) ALL FLASHINGS SHALL BE INSTALLED IN SUCH A MANNER SO AS TO PREVENT MOISTURE FROM ENTERING THE WALL OR TO REDIRECT IT
TO THE EXTERIOR.
2) ALL WALL PENETRATIONS SHALL BE TARGET FLASHED.
3) ALL WEATHER RESISTIVE BARRIERS SHALL HAVE POSITIVE LAPPING (SHINGLE STYLE) WHEN INSTALLED. LAPPING AND SEALING OF
SEAMS AND JOINTS SHALL BE BY MANUFACTURER'S REQUIREMENTS.
4) ALL BUILDING INTERFACES SHALL BE FLASHED TO PREVENT MOISTURE FROM ENTERING THE WALL.
5) ALL HORIZONTAL HARD SURFACES SHALL HAVE CODE REQUIRED ADEQUATE SLOPING FOR DRAINAGE.
6) AFTER REMOVAL OF DAMAGED MATERIALS, TREAT ADJACENT SURFACES WITH FUNGICIDE AND ANTI-MICROBIAL (BORA-CARE + MOLD CARE) TYPICAL. SURFACES MUST BE DRY BEFORE COVERING. REFER TO SECTION 02 40 00 DEMOLITION MOISTURE DAMAGE
GENERAL WATERPROOFING NOTES
1) THESE DRAWINGS DESCRIBE GENERAL REQUIREMENTS FOR WEATHERIZATION DETAILS. REFER TO ORIGINAL STRUCTURAL ENGINEERING DOCUMENTS FOR ANY STRUCTURAL CONCRETE, STEEL OR WOOD FRAMING REQUIREMENTS.
2) ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES, STANDARDS, AND MANUFACTURER'S INSTRUCTIONS.
REPORT ANY DISCREPANCIES TO CONSULTANT.
3) CONTRACTOR SHALL VERIFY CONDITIONS ON SITE BEFORE BEGINNING WORK AND REPORT ANY DISCREPANCIES TO
CONSULTANT.
4) THE CONTRACTOR SHALL BE FAMILIAR w/ THESE DRAWINGS AND DETAILS AND SHALL ENSURE THAT THEIR
WORKERS HAVE THE EXPERIENCE, TRAINING AND SKILLS REQUIRED TO EXECUTE THE WORK.
5) SUBMIT REQUEST FOR INFORMATION (RFI) TO THE CONSULTANT. SUBMIT ANY CHANGES IN THE CONTRACT VALUE IN THE
FORM OF A CHANGE ORDER PROPOSAL TO THE CONSULTANT.
6) NOTIFY CONSULTANT OF WORK SCHEDULE AND ACTIVITIES. PROVIDE SPECIAL CONSIDERATION FOR NOISY OPERATIONS, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES. PROTECT LANDSCAPING & FIXTURES.
7) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER IMAGES AND ILLUSTRATIONS.
8) ALL LUMBER SIZES INDICATED ARE NOMINAL UNLESS DIMENSIONED OR NOTED OTHERWISE.
9) EXTERIOR SHEATHING & FRAMING REPAIRS SHALL REQUIRE INSPECTIONS. COORDINATE INSPECTIONS WITH
BUILDING OFFICIALS PRIOR TO COVERING.
10) DO NOT INSTALL DAMAGED OR DEFECTIVE MATERIAL(S).
11) LAP WEATHER RESISTANT BARRIER OVER VERTICAL FLASHING/SAMF A MIN OF 4". UNLESS NOTED OTHERWISE.
12) REFER TO MATERIAL DATA SHEETS AND MANUFACTURER'S INSTRUCTIONS BEFORE INSTALLING ANY NEW MATERIALS
13) PROVIDE;
A) 2” MIN CLEAR @ ALL CLADDING TO HORIZONTAL HARD SURFACES
B) 6" MIN CLEAR @ ALL FRAMING TO FINISH GRADE
14) EXPOSED FASTENERS SHALL BE SEALED OR GASKETED. INSTALL & LOCATE ALL FASTENERS PER SMACNA.
15) HEM METAL FLASHING DRIP EDGES, TYPICAL. PROVIDE FULLY SOLDERED JOINTS IN SECTIONS OF
FLASHING JOINED TOGETHER AS INDICATED ON DRAWINGS.
16) PROVIDE GALVANIC SEPARATION MATERIAL BETWEEN DISSIMILAR METALS.
17) NOTIFY THE CONSULTANT OF ANY PREVIOUSLY UNDISCOVERED DAMAGE, DEFICIENCIES OR THREATS THAT COMPROMISE
THE FIRE AND/OR LIFE SAFETY OF THE BUILDING OCCUPANTS.
18) CONTRACTOR SHALL PROMPTLY REPORT ANY ACCIDENTAL DAMAGE AT NO ADDITIONAL COST TO THE OWNER.
19) CONTRACTOR SHALL REMOVE DEBRIS AND TRASH FROM THE SITE IMMEDIATELY. DISPOSE OF LEGALLY. KEEP THE
BUILDING AND GROUNDS CLEAN AND FREE OF REFUSE AT ALL TIMES.
20) CONTRACTOR SHALL DOCUMENT PRE-EXISTING CONDITIONS FOR REFERENCING DURING NEW CONSTRUCTION.
21) CONTRACTOR SHALL NOTIFY THE CONSULTANT OF ANY DISCOVERED MICROBIAL GROWTH DURING THE COURSE OF WORK.
22) ALL MATERIALS AND COMPONENTS ARE TO BE NEW UNLESS NOTED OTHERWISE
23) CONTRACTOR IS RESPONSIBLE FOR PROVIDING A TAPERED INSULATION SYSTEM TO ALLOW FOR PROPER ROOFING DRAINAGE. THIS INCLUDES THE INSTALLATION OF SADDLES AND CRICKETS, OR THE CORRECTION OF EXISTING SADDLES
AND CRICKETS.
24) CONTRACTOR IS RESPONSIBLE FOR PROVIDING NEW NECESSARY PERIMETER EDGE WOOD NAILER TO ALLOW FOR INSTALLATION OF NEW TAPERED INSULATION SYSTEM. REFER TO SECTION 06 10 00 ROUGH CARPENTRY FOR WOOD NAILER
REQUIREMENTS.
MOCK-UPS AND TESTING
GENERAL NOTES:
1) PRODUCT SUBMITTALS SHALL BE PROVIDED TO J2 FOR REVIEW AND APPROVAL PRIOR TO MOCK-UPS.
2) MOCK-UP REVIEW SHALL CONSIST OF A STEP BY STEP INSTALLATION SEQUENCE PERFORMED ON SITE BY
PERSONNEL WHO WILL BE PERFORMING THE ACTUAL INSTALLATION.
3) CONTACT J2 AT LEAST 48 HOURS IN ADVANCE TO SCHEDULE/REQUEST MOCK-UPS OR TESTING.
4) WATER TESTING AT WINDOWS AND DOORS SHALL BE PERFORMED PRIOR TO FULL SIDING INSTALLATION.
TEMPORARY SIDING IMITATING INSTALLED CONDITIONS SHALL BE UTILIZED.
REQUIRED MOCK-UPS/TESTING:
CONTRACTOR TO CONTACT J2 TO PERFORM AND/OR ARRANGE THE FOLLOWING MOCK-UP OR TESTING. THE LIST BELOW INDICATES THE MINIMUM REQUIREMENTS. OTHER CONDITIONS MAY REQUIRE ADDITIONAL MOCK-UPS OR TESTING AS
DETERMINED BY FIELD CONDITIONS.
BASE SCOPE : ROOF AREAS A, A1 + A2
SEE SHEET A1.1
A
B
S5.1
ALT #2 : AREA S6
ALT #1 : AREA S2
MOCK-UP/TESTING DESCRIPTIONS NOTES
SUBSTRATE REPAIR/PREPARATION VERIFY IF CITY INSPECTIONS ARE REQUIRED FOR REPAIRS.
ATTIC VENTILATION VERIFY EXISTING CONDITIONS PRIOR TO PROCEEDING
WITH WORK. IF THE ATTIC/RAFTER SPACE OF THE ROOF
REPLACEMENT AREA IS TO BE VENTED, CONTRACTOR
SHALL PROVIDE A SUBMITTAL FOR THE TYPE/QUANITY OF
ALL INTAKE AND EXHAUST VENTS FOR J2 REVIEW AND
APPROVAL PRIOR TO INSTALLATION. ALSO, SEE
VENTILATION NOTES ON SHEET A0.2
ROOFING UNDERLAYMENT
RIGID INSULATION
TAPER PLAN REQUIRED FOR J2 APPROVAL PRIOR TO
INSTALLATION
COVERBOARD INSTALLATION AND
FASTENING
ROOF PENETRATIONS ONE OF EACH PENETRATION TYPE IN EACH ROOF TYPE
ROOF DRAINS
ROOF-TO-WALL AND CURBS ONE OF EACH TYPE
ROOF EDGE EACH CONDITION AT EACH ROOF TYPE
TRANSITION BETWEEN ROOF TYPES
ACCESS HATCH
GUTTERS AND DOWNSPOUTS
GABLE WALL ATTIC ACCESS DOOR
WALL COATING
R3
R3
R3
ALT #3 : AREA B
BASE SCOPE :
AREAS A, A1 + A2
A1.1
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
DISTRICT
PROJECT
SCOPE OF WORK AND COMPONENT REPLACEMENT SCHEDULE
KEYNOTE BUILDING ELEMENT DESCRIPTION OF WORK REPLACEMENT MATERIAL SPECIFICATION SECTION APPLICABLE DETAILS
GENERAL ROOF ASSEMBLY
DEMOLITION
CONTRACTOR IS RESPONSIBLE FOR TESTING FOR HAZARDOUS
MATERIALS PRIOR TO MOBILIZATION. REMOVE AND LEGALLY DISPOSE
OF ALL ROOFING, FLASHING, INSULATION, COVERBOARDS,
ACCESSORIES AND OTHER MATERIALS ABOVE THE EXISTING PLYWOOD
DECK.
NA 02 40 00 DEMOLITION NA
SHEATHING REPAIR
(ALLOWANCE ITEM)
INSPECT PLYWOOD ROOF DECK AND REPAIR/REPLACE AS NEEDED. MATCH EXISTING
SHEATHING THICKNESS
(APA RATING) AND
FASTENING
06 10 00 ROUGH CARPENTRY NA
GENERAL ROOF ASSEMBLY
INSTALLATION
INSTALL WOOD NAILERS AT ROOF PENETRATIONS, PERIMETERS, ETC.
AS NEEDED TO PROPERLY ATTACH ROOFING. INSTALL NEW ROOFING
UNDERLAYMENT, TAPERED INSULATION, ADDITIONAL INSULATION
(VARIES), COVERBOARD AND BUILT UP ROOFING BASE PLY AND CAP
SHEET. CONTRACTOR TO PROVIDE SHOP DRAWINGS SHOWING SLOPE,
CRICKETS, ETC. FOR J2 REVIEW AND APPROVAL PRIOR TO
INSTALLATION.
UNDERLAYMENT PER
SPECS; INSULATION
VARIES PER ROOF TYPE;
COVER BOARD PER SPECS;
2-PLY SYSTEM PER SPECS
06 10 00 ROUGH CARPENTRY; 07 21 00
THERMAL INSULATION; 07 52 00 MODIFIED
BITUMINOUS MEMBRANE ROOFING; 07 72 00
ROOF ACCESSORIES
W SHEETS
STEEP SLOPE TO BUR
TRANSITION
EXTEND BUR 24" UP STEEP SLOPE ROOFS PRIOR TO INSTALLING STEEP
SLOPE ROOF. REMOVE AND REPLACE SHINGLES AS NECESSARY TO
PERFORM WORK.
PER SPECS 07 31 13 ASPHALT SHINGLES; 07 52 00
MODIFIED BITUMINOUS MEMBRANE ROOFING
1/W1.2
PLUMBING AND HVAC
PENETRATIONS
INSTALL NEW BASE AND CAP FLASHINGS, CANT STRIP AND
ACCESSORIES AT ALL PLUMBING AND HVAC DUCT PENETRATIONS.
REMOVE AND REINSTALL EXISTING VENT HOODS AS NEEDED TO
PERFORM WORK.
ASSUME RE-USE EXISTING
MECHANICAL HOODS;
ASSUME NEW LEADS AT
PIPES
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
1/W1.1; 2/W1.1
HOT PIPE PENETRATIONS INSTALL NEW BASE AND CAP FLASHINGS, STORM COLLAR, UMBRELLA
AND DRAWBAND AT EXSITING HEAT STACK. REMOVE AND REINSTALL
HOOD AS NEEDED TO PERFORM WORK.
EXISTING HEAT STACK TO
REMAIN; ASSUME NEW
STORM COLLAR,
"UMBRELLA" AND BAND
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
3/W1.1
7 PITCH POCKET INSTALL NEW PITCH PAN, DRAWBAND AND UMBRELLA AT EXISTING
ROOF TOP MOUNTED MISC. EQUIPMENT AS NEEDED.
PER MANUFACTURER 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
4/W1.1
ROOF DRAINS INSTALL NEW CAST IRON DRAIN, WITH CLAMPING RING AND METAL
STRAINER. CONNECT TO EXISTING PLUMBING. EXTEND/MODIFY PIPE
AS NEEDED TO PERFORM WORK.
ASSUMES EXISTING CAST
IRON PIPE; NEW DRAIN
BODY, CLAMPING RING
AND STRAINER
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
5/W1.1; 4/W1.2
MECHANICAL CURBS TEMPORARILY RELOCATE ROOF TOP EQUIPMENT TO COMPLETE
WORK. RAISE CURB AS NEEDED TO ENSURE CURB IS 8" MIN ABOVE
NEW ROOFTOP ELEVATION. INSTALL CAP AND BASE FLASHING,
COUNTER FLASHING AND ACCESSORIES. REMOVE OBSOLETE CURBS
AND REPAIR RESULTING HOLE IN DECK.
PER DETAIL 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
6/W1.1
ROOF HATCH REMOVE AND REINSTALL ROOF HATCH AS NEEDED TO PROPERLY
INTEGRATE NEW ROOFING CURB. ADD FRAMING AS REQUIRED TO
ENSURE HATCH IS 8" MIN. ABOVE ROOF DECK. PAINT ROOF HATCH.
RE-USE EXISTING 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
7/W1.1
HORIZONTAL PIPES INSTALL NEW PRE-FABRICATED PIPE SUPPORT AND PROTECTION PADS
AT EXISTING HORIZONTAL PIPES. PAINT PIPE YELLOW FOR HIGH
VISIBILITY.
PER MANUFACTURER 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
8/W1.1; 9/W1.1
12 SLEEPERS INSTALL ADDITIONAL CAP SHEET PROTECTION LAYER UNDER ALL
SLEEPER LOCATIONS AT MEP EQUIPMENT.
PER MANUFACTURER 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
9/W1.1
WALL/ROOF TRANSITION -
CONCRETE OR MASONRY
WALL
INSTALL NEW CANT STRIP, BASE AND CAP FLASHING AND NEW METAL
COUNTERFLASHING KERF CUT INTO MASONRY AT ROOF TO WALL
TRANSITION.
PER SPECS AND DETAILS;
PROVIDE METAL SHOP
DRAWINGS
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 62 00 SHEET METAL FLASHING
AND TRIM
6/W1.2
WINDOW/ROOF TRANSITION REMOVE AND REINSTALL WINDOW IN ORDER TO ADD SILL PAN
PROPERLY INTEGRATED WITH ROOFING ASSEMBLY. WINDOW JAMB
AND HEAD TO BE INSTALLED AS PER INDUSTRY STANDARDS (AAMA
2400) AS FAR AS PRACTICABLE. USE DYNAMIC SEALANT JOINTS AT
WINDOW FRAME TO DISSIMILAR MATERIALS. DO NOT INSTALL
SEALANT TO BLOCK ANY MEANS OF DRAINAGE.
RE-USE EXISTING
WINDOW
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 62 00 SHEET METAL FLASHING
AND TRIM; 07 92 00 JOINT SEALANT
2/W1.2
ROOF EDGE - NO GUTTER INSTALL NEW ROOF EDGE METAL WITH GRAVEL STOP DETAIL.
CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR REVIEW AND
APPROVAL PRIOR TO FABRICATION.
PER SPECS AND DETAILS;
PROVIDE METAL SHOP
DRAWINGS
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 62 00 SHEET METAL FLASHING
AND TRIM
7/W1.2; 8/W1.2
ROOF EDGE - GUTTER INSTALL NEW ROOF EDGE METAL AND NEW GUTTER WITH STRAP
FASTENERS AND NOT SPIKES. CONTRACTOR TO PROVIDE SHOP
DRAWINGS FOR REVIEW AND APPROVAL PRIOR TO FABRICATION.
REMOVE AND REPLACE DOWNSPOUTS WITH CLEAN-OUTS AT THE
BASE. INSTALL NEW SPLASH BLOCKS WHERE DOWNSPOUTS DRAIN
ONTO NEW BUR. PROVIDE AND INSTALL SOFFIT VENT COVERS,
AND ACCESSORIES AS INDICATED ON DRAWINGS AND
DESCRIPTION OF WORK.
PER SPECS AND DETAILS;
PROVIDE METAL SHOP
DRAWINGS
07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 62 00 SHEET METAL FLASHING
AND TRIM
3/W1.2
WALK PADS INSTALL NEW WALK PADS ON ROOF SURFACE TO PROVIDE PATHS FOR
MAINTENANCE FROM ROOF ACCESS POINTS TO MAIN MECHANICAL
EQUIPMENT.
PER MANUFACTURER 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 72 00 ROOF ACCESSORIES
NA
WALL COATING APPLY COATINGS ON CONCRETE AND MASONRY WALLS AT ALL AREAS
ABOVE NEW ROOF TO WALL TRANSITIONS. REPAIR/FILL ALL CRACKS
PER MANUFACTURER REQUIREMENTS. (LARGE CRACKS WILL NEED A
URETHANE FILLER AND SMALLER CRACKS MAY REQUIRE A DETAIL
COAT AND FINISH COAT.)
PER SPECS 09 91 13 EXTERIOR PAINTING; 07 92 00 JOINT
SEALANTS
NA
WALL/ROOF TRANSITION -
VINYL SIDING
INSTALL NEW CANT STRIP, BASE AND CAP FLASHING. EXTEND NEW
ROOF MEMBRANE UP UNDER SIDING AND WRB FOR A MINIMUM OF
8". REMOVE AND REINSTALL VINYL SIDING AS NEEDED TO PERFORM
WORK.
RE-USE SIDING 07 52 00 MODIFIED BITUMINOUS MEMBRANE
ROOFING; 07 62 00 SHEET METAL FLASHING
AND TRIM
7/W1.3
NA FALL PROTECTION NOT INCLUDED. BY OTHERS IF NEEDED. NA NA NA
A
S2
A2
S
A1
S5
LEGEND :
R2
R2
R1
KEY:
RX
= ROOF #
= ROOF TYPE SHEET A0.2
= KEYNOTE THIS SHEET
= ROOF SLOPE MIN. 1/4" PER FOOT. RIDGES / VALLEYS SHOWN
ARE APPROX. CONTRACTOR TO PROVIDE TAPER PLAN
SUBMITTED FOR J2 APPROVAL.
= EXISTING SKYLIGHT TO REMIAN
= EXISTING MECHANICAL UNIT
A
M
S
RD
DS
= ROOF DRAIN PER SPECS
= EXISTING DOWNSPOUT. USE SPLASHBLOCK WHERE DOWNSPOUT
DRAINS ONTO ROOF. NOT ALL INDICATED. NO SPANS FURTHER THAN
40 FT.
= NEW PARAPET COPING OR NEW EXPANSION JOINT / CURB
= NEW MISC. MECHANICAL EQUIPMENT. NOTE THAT NOT ALL EQUIPMENT
IS SHOWN. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS
SCALE :A1.1
1 ROOF AREA : A
NTS
SCALE :A1.1
2 ROOF AREA : A1
NTS
SCALE :A1.1
3 ROOF AREA : A2
NTS
A2
A A1
= APPROX. PROPOSED WALK PAD LOCATION
= EX. GAS PIPE
= NEW GUTTER. POSITIVE SLOPE TO DRAIN. EXPANSION JOINTS @ 50'
O.C. SEE SPECS
RD
RDRD
DS
DS
1 2 3 TYP
S4
S3
S1
B
1 2 3 TYP
TYP
19 19
TYP
TYP
13 18 TYP
TYP
TYP
TYP
TYP
SIM.
5 6 7 TYP12
NOT ALL LOCATIONS
SHOWN
W
W
W
ALT #1, #2, #3, #4:
AREAS S2, S6, S5, B
A1.2
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
DISTRICT
PROJECT
SCOPE OF WORK AND COMPONENT REPLACEMENT SCHEDULE
KEYNOTE BUILDING ELEMENT DESCRIPTION OF WORK REPLACEMENT MATERIAL SPECIFICATION SECTION APPLICABLE DETAILS
GENERAL ROOF ASSEMBLY
DEMOLITION
CONTRACTOR IS RESPONSIBLE FOR TESTING FOR HAZARDOUS
MATERIALS PRIOR TO MOBILIZATION. REMOVE AND LEGALLY DISPOSE
OF ALL ROOFING, FLASHING, INSULATION, COVERBOARDS,
ACCESSORIES AND OTHER MATERIALS ABOVE THE EXISTING PLYWOOD
DECK.
NA 02 40 00 DEMOLITION NA
SHEATHING REPAIR
(ALLOWANCE ITEM)
INSPECT PLYWOOD ROOF DECK AND REPAIR/REPLACE AS NEEDED. MATCH EXISTING
SHEATHING THICKNESS
(APA RATING) AND
FASTENING
06 10 00 ROUGH CARPENTRY NA
GENERAL ROOF ASSEMBLY
INSTALLATION
REMOVE ALL EXISTING ROOFING, UNDERLAYMENT AND PENETRATION
FLASHINGS INCLUDING PIPE FLASHINGS AND BOX VENTS. INSTALL
NEW AS PER DETAILS AND SPECS. SEE ADDITIONAL INFORMATION ON
INDIVIDUAL COMPONENTS NOTED BELOW.
PER SPECS 02 40 00 DEMOLITION AND MOISTURE DAMAGE
07 31 13 ASPHALT SHINGLES
07 72 00 ROOF ACCESSORIES
07 62 00 SHEET METAL FLASHING
W SHEETS
20 ROOF EAVE
INSTALL NEW ROOF EAVE DRIP METAL UNDERNEATH NEW
UNDERLAYMENT AT EAVES. EXTEND METAL INTO GUTTER WHERE
APPLICABLE.
PER DETAILS AND SPECS
(SELF-ADHERED
UNDERLAYMENT AT
EAVES)
07 62 00 SHEET METAL FLASHING; 07 31 13
ASPHALT SHINGLES
1/W1.3; 2/W1.3
21 GUTTERS AND
DOWNSPOUTS
REPLACE ALL GUTTERS AND DOWNSPOUTS. INSTALL CLEANOUTS AT
GROUND LEVEL DOWNSPOUTS. EXTEND UPPER DOWNSPOUTS
ACROSS LOWER ROOF AND INTO LOWER ROOF GUTTER SO THAT NO
DOWNSPOUTS DRAIN DIRECTLY ON ROOFING MATERIAL. ENSURE
PROPER SPACE BETWEEN GUTTERS AND SIDING AND ALSO BETWEEN
GUTTERS AND ROOF SO THAT THEY WILL NOT CUT INTO ROOFING AT
DORMERS, VALLEYS, AND ADJACENT ROOFS.
6" "K" STYLE GUTTERS
AND 3"X4" DOWNSPOUTS 07 62 00 SHEET METAL FLASHING
1/W1.3; 2/W1.3
22 ROOF RAKE INSTALL NEW "T" METAL AT RAKES INSTALLED OVER ROOF
UNDERLAYMENT.
PER DETAILS AND SPECS
(SELF-ADHERED
UNDERLAYMENT AT
RAKES)
07 62 00 SHEET METAL FLASHING; 07 31 13
ASPHALT SHINGLES
3/W1.3; 4/W1.3
BARGE BOARDS AND FASCIA
(ALLOWANCE)
REMOVE AND REPLACE DECAYED TRIM MATERIAL AS NEEDED. NOTIFY
J2 BUILDING CONSULTANTS PRIOR TO REPLACEMENT. ALL NEW
MATERIALS TO BE PRIMED AND PAINTED TO MATCH. ENSURE 2"
SPACING BETWEEN WOOD FASCIA/BARGE BOARDS AND ROOFING.
MATCH EXISTING SIZE;
PRESERVATIVE TREATED
AND PRIMED
WHITEWOOD
06 10 00 ROUGH CARPENTRY
09 90 13 EXTERIOR PAINTING
3/W1.3; 4/W1.3
24 STEP FLASHING AND
DIVERTERS
INSTALL NEW STEP FLASHING. ENSURE A 1" MIN. SEPARATION FROM
EXISTING SIDING TO ROOF (2" PREFERRED). MODIFY EXISTING SIDING
AS NECESSARY. VERIFY IF EXISTING ROOFING UNDERLAYMENT
EXTENDS UP WALLS. IF SO, LEAVE 12" OF ROOFING UNDERLAYMENT
INTACT ON THE ROOF DECK AND INSTALL NEW UNDERLAYMENT
UNDER EXISTING. IF NOT, EXTEND ROOFING UNDERLAYMENT 5" MIN.
(8" PREFERRED WHERE POSSIBLE) UP WALLS PRIOR TO STEP FLASHING
INSTALLATION. INSTALL NEW PUNCH-LOCKED AND SEALED DIVERTERS
WHERE APPLICABLE. AT ROOF TO WALL CONDITIONS WHERE STEP
FLASHING AND/OR DIVERTERS ARE OMITTED, INSTALL NEW STEP
FLASHING AND DIVERTERS PER DESIGN DOCS.
10" SHEET METAL
SHINGLES (5" UP WALL
AND 5" SHINGLED INTO
ROOFING)
07 31 13 ASPHALT SHINGLES
07 62 00 SHEET METAL FLASHING
07 27 00 WEATHER RESISTIVE BARRIER
5/W1.3; 6/W1.3
25 ROOF APRON FLASHING
INSTALL NEW APRON FLASHING. ENSURE A 1" MIN. SEPARATION
FROM EXISTING SIDING TO ROOF (2" PREFERRED). MODIFY EXISTING
SIDING AS NECESSARY. VERIFY IF EXISTING ROOFING UNDERLAYMENT
EXTENDS UP WALLS. IF SO, LEAVE 12" OF ROOFING UNDERLAYMENT
INTACT ON THE ROOF DECK AND INSTALL NEW UNDERLAYMENT
UNDER EXISTING. IF NOT, EXTEND ROOFING UNDERLAYMENT 5" MIN.
(8" PREFERRED WHERE POSSIBLE) UP WALLS PRIOR TO APRON
FLASHING INSTALLATION.
AT VAULTED ENTRYWAY CEILINGS WHICH ARE ASSUMED TO BE
VENTED, INSTALL NEW EXHAUST VENT ASSEMBLY UNDER APRON
FLASHING WHERE APPLICABLE PER DESIGN DOCUMENTS.
10" SHEET METAL (5" UP
WALL AND 5" ONTO
ROOFING)
07 31 13 ASPHALT SHINGLES
07 62 00 SHEET METAL FLASHING
07 27 00 WEATHER RESISTIVE BARRIER
7/W1.3; 8/W1.3
26 VALLEYS
INSTALL FULL WIDTH ROLL OF SELF-ADHERED UNDERLAYMENT AT ALL
VALLEYS AND THEN EXTEND FIELD UNDERLAYMENT ACROSS VALLEY
WITH 24" OVERLAP. INSTALL SHEET METAL VALLEY FLASHING AS PER
MANUFACTURES INSTRUCTIONS.
SHINGLES AND
UNDERLYAMENT PER
SPECS (SELF-ADHERED
UNDERLAYMENT AT
VALLEYS)
07 31 13 ASPHALT SHINGLES
07 62 00 SHEET METAL FLASHING
9/W1.3
27 HVAC EXHAUST HOODS
INSTALL NEW HVAC EXHAUST STEM VENTS AT ALL EXHAUST DUCTS.
ENSURE DUCTS ARE CONNECTED AND SEALED TO STEM VENT SO THAT
THEY VENT OUTSIDE. ASSUME FURNACE AND RADON VENTING TO
REMAIN. ENSURE STORM COLLARS ARE PROPERLY SEALED. SHINGLE
ROOF ACCESSORY FLANGES INTO NEW ROOFING UNDERLAYMENT
AND ROOFING IN A WEATHERBOARD MANNER.
RE-USE EXISTING FURNACE
VENTS. NEW STEM VENTS
PER SPECS
07 72 00 ROOF ACCESSORIES; 07 31 13
ASPHALT SHINGLES
1/W1.4; 2/W1.4
28 PIPE BOOTS
INSTALL NEW PIPE BOOT FLASHING AT ALL PLUMBING VENTS.
SHINGLE INTO NEW ROOFING UNDERLAYMENT AND ROOFING IN A
WEATHERBOARD MANNER.
ULTIMATE PIPE FLASHING
24 GA. GALVANIZED
KYNAR COATED
07 72 00 ROOF ACCESSORIES; 07 31 13
ASPHALT SHINGLES
3/W1.4
29 ATTIC INTAKE AND EXHAUST
VENTS
VERIFY EXISTING EXHAUST AND INTAKE VENTS AND/OR INSTALL NEW
ATTIC EXHAUST AND INTAKE VENTS TO MEET CODE REQUIREMENTS.
EACH PORTION OF THE ATTIC MUST HAVE INTAKE AND EXHAUST
VENTILATION AS PER IBC. VERIFY LOCATION OF ATTIC DRAFT STOPS
AND OVERFRAMING PRIOR TO PLACING VENTS. ENSURE A CLEAR
PATH OF AIRFLOW.
PER SPECS 07 72 00 ROOF ACCESSORIES; 07 31 13
ASPHALT SHINGLES
4/W1.4; 5/W1.4; 6/W1.4
30 TOP OF ROOF METAL INSTALL NEW CAP METAL ON SHINGLES AT TOP OF ROOF TO LOWER
WALL LOCATION.
PER DETAIL AND SPECS 07 31 13 ASPHALT SHINGLES; 07 62 00 SHEET
METAL FLASHING
7/W1.4
NA FALL PROTECTION NOT INCLUDED. BY OTHERS IF NEEDED. NA NA NA
A
S2
A2
S6
A1
S5
LEGEND :
R3
R3
KEY:
RX
= ROOF #
= ROOF TYPE SHEET A0.2
= KEYNOTE THIS SHEET
= ROOF SLOPE MIN. 1/4" PER FOOT. RIDGES / VALLEYS SHOWN
ARE APPROX. CONTRACTOR TO PROVIDE TAPER PLAN
SUBMITTED FOR J2 APPROVAL.
= EXISTING SKYLIGHT TO REMIAN
= EXISTING MECHANICAL UNIT
A
M
S
RD
DS
= ROOF DRAIN PER SPECS
= EXISTING DOWNSPOUT. USE SPLASHBLOCK WHERE DOWNSPOUT
DRAINS ONTO ROOF. NOT ALL INDICATED. NO SPANS FURTHER THAN
40 FT.
= NEW PARAPET COPING OR NEW EXPANSION JOINT / CURB
= NEW MISC. MECHANICAL EQUIPMENT. NOTE THAT NOT ALL EQUIPMENT
IS SHOWN. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS
= APPROX. PROPOSED WALK PAD LOCATION
= EX. GAS PIPE
= NEW GUTTER. POSITIVE SLOPE TO DRAIN. EXPANSION JOINTS @ 50'
O.C. SEE SPECS
B
S4
S3
S1
B
S2
A1
S6
SCALE :A1.2
1 ROOF AREA : S6 (ALT #2)
NTS
SCALE :A1.2
2 ROOF AREA : S2 (ALT #1)
NTS
1 2 3 TYP
1 2 3 TYP
S S S
S S S
M
DS
12 4
20 21 TYP
27 28 29
TYP NOT SHOWN
21 TYP
25 SIM. 26
30 TYP
27 28 29
TYP NOT SHOWN
SCALE :A1.2
3 ROOF AREA : B (ALT #3)
NTS
1 W1.1 2 W1.1 3 W1.1
4 W1.1 5 W1.1 6 W1.1
7 W1.1 8 W1.1 9 W1.1
PLUMBING STACK - BUR ID: 662
SCALE: NTS
ROLL DOWN LEAD FLASHING 1" MIN. DOWN INTO PIPE
PLUMBING VENT STACK
RUBBERIZED ASPHALT SEALANT
BASE FLASHING PLY PER DESIGN DOCS; 8" MIN. ON FIELD
MULTI-PLY SBS ROOFING MEMBRANE PER
DESIGN DOCS; FULLY ADHERE TO CANT,
ROOF SURFACES
SET LEAD FLANGE IN MASTIC, PRIME FLANGE BEFORE STRIPPING
" M
IN
4" MIN.
COVERBOARD PER DESIGN DOCS
RIGID INSULATION PER DESIGN DOCS; TAPERED TO ALLOW SLOPE TO DRAIN
ROOFING UNDERLAYMENT PER DESIGN DOCS
SHEATHING PER DESIGN DOCS
SET FLANGE IN ROOF CEMENT, ASPHALT PRIMER BOTH SIDES
EXHAUST FAN - BUR ID: 661
SCALE: NTS
METAL EXHAUST FAN COVER
FLASHING PLY FASTENED 8" O.C.
CAP FLASHING PLY PER DESIGN DOCS; 9" MIN. ON FIELD
BASE FLASHING PLY PER DESIGN DOCS; 6" MIN. ON FIELD
MULTI-PLY SBS ROOFING MEMBRANE PER DESIGN
DOCS; FULLY ADHERE TO CANT, ROOF SURFACES
8" M
IN
CANT STRIP
COVERBOARD PER DESIGN DOCS
TAPERED RIGID INSULATION TO ALLOW FOR SLOPE TO DRAIN; STAGGER ALL JOINTS PER SPECS
ROOFING UNDERLAYMENT PER DESIGN DOCS
SUBSTRATE PER DESIGN DOCS
MIN. 2 GASKETED FASTENERS PER SIDE
HEAT STACK - BUR ID: 660
SCALE: NTS
TEMPERATURE APPROPRIATE ELASTOMERIC SEALANT
APPROVED FILLER MATERIAL
8" MIN. ON FIELD BASE FLASHING PLY PER
DESIGN DOCS; FULLY ADHERE TO SURFACES
MULTI-PLY SBS ROOFING MEMBRANE
PER DESIGN DOCS; FULLY ADHERE
TO ROOF SURFACES
HEAT STACK
DRAWBAND OR WELD
UMBRELLA TO STACK
UMBRELLA
STORM COLLAR SET IN
MASTIC, PRIME FLANGE
COVERBOARD PER DESIGN DOCS
ROOFING UNDERLAYMENT PER DESIGN DOCS
24 GA. METAL FLANGE AND SLEEVE
SET IN ROOFING CEMENT
4" MIN. TAPERED RIGID INSULATION TO ALLOW FOR
SLOPE TO DRAIN; STAGGER ALL JOINTS
FIRE RATED SEALANT
SUBSTRATE PER DESIGN DOCS
SET FLANGE IN ROOF CEMENT,
ASPHALT PRIMER BOTH SIDES
4" MIN.
PITCH POCKET - BUR ID: 828
SCALE: NTS
SEALANT
POURABLE SEALANT, 1" MIN.
(OVER NON-SHRINK GROUT)
MULTI-PLY SBS ROOFING MEMBRANE
PER DESIGN DOCS; FULLY ADHERE
TO ROOF SURFACES
WEATHERPROOF SHEET METAL PITCH
PAN, SOLDERED/WELDED
(4" MIN. HEIGHT)
4" MIN.
COVERBOARD PER DESIGN DOCS
SUBSTRATE PER DESIGN DOCS
ROOFING UNDERLAYMENT
PER DESIGN DOCS
TAPERED RIGID INSULATION TO ALLOW FOR
SLOPE TO DRAIN; STAGGER ALL JOINTS
EQUIPMENT BASE OR OTHER
ROOF-MOUNT PENETRATION
8" MIN. ON FIELD BASE FLASHING PLY
PER DESIGN DOCS
SET FLANGE IN ROOF CEMENT,
ASPHALT PRIMER BOTH SIDES
ROOF DRAIN - BUR ID: 827
SCALE: NTS
NEW TAPERED RIGID
INSULATION
BASE PLY PER DESIGN DOCS
METAL STRAINER/LEAF GUARD
EX. STRUCTURE
BLOCKING AS REQUIRED TO
SUPPORT DRAIN
SLOPE 3:12 MAX (1
4:12 MIN.)
ROOFING UNDERLAYMENT
PER DESIGN DOCS
PIPE INSULATION
RECOMMENDED TO MINIMIZE
CONDENSATION
CLAMPING RING
MANUFACTURER APPROVED
DRAIN
4"
LEAD FLASHING
BASE FLASHING PER DESIGN
DOCS
CAP SHEET PER DESIGN DOCS
INSTALL ALL LAYERS
IN ROOFING MASTIC
TYPICAL CURB - BUR ID: 664
SCALE: NTS
SUBSTRATE PER DESIGN DOCS
ROOFING UNDERLAYMENT
PER DESIGN DOCS
6"
MIN. ALONG ROOF
9"
MIN. ALONG ROOF
FI
EL
D
VF
Y
1" M
IN
NEW 2X
FRAMING TO
ALLOW FOR
ADDED HT OF
RIGID
INSULATION
EX. CURB
FRAMING
UNIT
MOUNTING
CURB
8" MI
N.
RIGID INSULATION PER
DESIGN DOCS
MANUFACTURED TRUSS SYSTEM,
TO MATCH EXISTING
TAPERED RIGID INSULATION TO
ALLOW FOR SLOPE TO DRAIN
COVERBOARD PER DESIGN DOCS
EX. MECHANICAL UNIT; BASE OF UNIT TO EXTEND
1/2" MIN. BEYOND AND DOWN OVER TOP OF CURB
SEALING MATERIAL; MUST BE
CONTINUOUS ON THE PERIMETER
COUNTERFLASHING PER
DESIGN DOCS
ROOF HATCH - BUR ID: 839
SCALE: NTS SLEEPER - BUR ID: 831
SCALE: NTS
NEW COVERBOARD PER DESIGN DOCS
NEW OR EXISTING INSULATION PER DESIGN DOCS
ROOFING UNDERLAYMENT PER DESIGN DOCS
EXISTING SUBSTRATE
WOOD SLEEPER SIZED AND SPACED
SO THAT LOAD DOES NOT EXCEED 16 P.S.I. CAP SHEET PROTECTION LAYER
ADHERED IN FLASHING CEMENT
BUILT-UP ROOFING PER
DESIGN DOCS
MECHANICAL EQUIPMENT
ATTACHMENT BY OTHERS.
2" MIN.
NOTES:
1. DO NOT INSTALL SLEEPERS OVER
BATTEN STRIPS, FASTENER HEADS,
METAL PLATES OR FIELD SEAMS.
2. GRANULES MUST BE EMBEDDED
WHEN THERMALLY FUSING GRANULE
SURFACED CAP SHEET.
3. DO NOT USE FOR PIPE SUPPORT.
REFER TO DETAIL 8/W1.1.
PIPE PEDESTAL - BUR ID: 830
SCALE: NTS
NEW COVERBOARD PER DESIGN DOCS
NEW OR EXISTING INSULATION PER DESIGN DOCS
ROOFING UNDERLAYMENT PER DESIGN DOCS
EXISTING SUBSTRATE
ROOFTOP PIPE PEDESTAL
PER SPECS
CAP SHEET PROTECTION LAYER
ADHERED IN FLASHING CEMENT
BUILT-UP ROOFING PER
DESIGN DOCS
MECHANICAL PIPE PAINTED YELLOW
2" MIN.
NOTES:
1. DO NOT INSTALL SLEEPERS OVER
BATTEN STRIPS, FASTENER HEADS,
METAL PLATES OR FIELD SEAMS.
2. GRANULES MUST BE EMBEDDED
WHEN THERMALLY FUSING GRANULE
SURFACED CAP SHEET.
EXISTING SUBSTRATE
ROOFING UNDERLAYMENT
PER DESIGN DOCS
6"
MIN. ALONG ROOF
9"
MIN. ALONG ROOF
8" MI
N.
RIGID INSULATION
PER DESIGN DOCS
METAL ROOF HATCH INSTALLED
PER MANUFACTURER
COVERBOARD PER DESIGN DOCS
TAPERED RIGID INSULATION TO
ALLOW FOR SLOPE TO DRAIN
CAP FLASHING
CAP PLY
BASE FLASHING
BASE PLY
CAP FASTENERS PER
MANUFACTURER, TYP.
GASKETED FASTENER
WEATHERIZATION
DETAILS - ROOF
W1.1
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
DISTRICT
PROJECT
1 W1.2 2 3
4 5 6
7 8
W1.2 W1.2
W1.2 W1.2
W1.2 W1.2
26 GA. METAL BACK ANGLE 3/4" HIGH - WITH 1/8" HEM TO OUTSIDE
- PRE FINISHED WHITE TO INTERIOR
INTERMITTENT 1/4" SHIMS
BACKER ROD & SEALANT W/ RITICULATED
FOAM WEEPS AT 2 LOCATIONS MIN.
WINDOW SILL TRIM OR GWB WRAP
MODIFIED AS NECESSARY TO
ACCOMMODATE BACK ANGLE.
WINDOW SILL AT ROOF - BLOCK FRAME WINDOW/BUR ID: 850
SCALE: NTS
ROOFING UNDERLAYMENT
BASE SHEET
CAP SHEET
CAP FLASHING
BASE FLASHING
ROOFING UNDERLAYMENT
EX. SUBSTRATE
INSULATION PER DESIGN DOCS
COVERBOARD PER DESIGN DOCS
BLOCK FRAME WINDOW
12" MIN. BASE FLASHING
METAL FLASHING
SET IN ROOF CEMENT
GUTTER
WOOD NAILER(S)
ROOFING UNDERLAYMENT PER DESIGN DOCS
INSULATION PER DESIGN DOCS
EXISTING SUBSTRATE
ROOF EDGE AT GUTTER - BUR ID: 845
SCALE: NTS
2" MIN.
BASE PLY
EX. CLADDING
COVERBOARD PER
DESIGN DOCS
CAP FLASHING
3-INCHES O.C. MAX.,
IN TWO STAGGERED ROWS.
CAP SHEET
NAILS @ 8" O.C.
GUTTER SPACERS - AS SPECIFIED;
18-INCHES O.C. PLACE SPACERS AT
LOCATIONS BETWEEN HANGERS.
FOLDED METAL IS UNACCEPTABLE.
SEALANT - APPLY TO GUTTER EDGE AT ROOFING
MEMBRANE TERMINATION AS SHOWN. TOOL
SEALANT AFTER INSTALLATION.
PROVIDE GUTTER HANGERS 18-INCHES O.C. -
FABRICATE FROM 1-INCH X 1/8-INCH GALV. STEEL,
PAINTED TO MATCH GUTTER. SECURE TO
SUBSTRATE WITH FASTENERS APPROPRIATE FOR
THE SUBSTRATE ENCOUNTERED. SECURE WITH
TWO FASTENERS, MINIMUM, PER HANGER.
EXISTING ROOF FRAMING
COMPOSITION SHINGLE TO 2-PLY ROLLED ROOF TRANSITION ID: 371
SCALE: NTS
8" MIN
2"4 1/32"
1'-6"
ROOF SHEATHING PER DESIGN DOCS
BASE SHEET EXTENDS 18" MIN. PER DESIGN
DOCS
2'-0"
BASE FLASHING EXTENDS A FULL ROLL WIDTH
24" MIN. PER DESIGN DOCS, INSTALL IN ROOFING
ADHESIVE PER DESIGN DOCS
SELF-ADHERED UNDERLAYMENT PER
DESIGN DOCS
9" STARTER COMPOSITION SHINGLE
PER DESIGN DOCS
COMPOSITION SHINGLE PER DESIGN
DOCS
2"
CAP NAIL FASTENERS @ 6" O.C.
CAP NAIL FASTENERS @ 12" O.C.
ROOF TO PARAPET - BUR ID: 665
SCALE: NTS
COVERBOARD PER DESIGN DOCS
RIGID INSULATION PER DESIGN DOCS
TAPERED RIGID INSULATION TO ALLOW FOR
SLOPE TO DRAIN
CANT STRIP SET
IN ADHESIVE PER
DESIGN DOCS
6"
MIN. ALONG ROOF
8" MI
N.
FASTENER AND SEALANT PER ROOF MFR
COUNTERFLASHING PER DESIGN DOCS
MTL FLASHING PER DESIGN DOCS; EXTEND OVER
COUNTER FLASHING AND UP TO T/O PARAPET
FASTENERS @ 18" O.C.
EX. WRB
9"
MIN. ALONG ROOF
ROOFING UNDERLAYMENT
PER DESIGN DOCS
SUBSTRATE PER DESIGN DOCS
4" MI
N.
INSULATION AND
AIR BARRIER PER
DESIGN DOCS
8" MI
N.
CAP FLASHING
CAP PLY
BASE FLASHING
BASE PLY
L
CC
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
MODIFIED BITUMEN BASE PLY
MODIFIED BITUMEN SURFACING PLY
PLAN VIEW OF ROOF SUMP AREA
SCALE: NONE
TAPERED INSULATION/EDGE STRIPS AS NEEDED
TO RESULT IN 8'-0" X 8'-0" SUMP AREA
ROOF DRAIN
APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA
CONSTRUCTION AND SLOPE REQUIREMENTS
15" 4" MIN
IN
ST
AL
L T
AP
ER
ED
P
OL
YI
SO
CY
AN
UR
AT
E
IN
SU
LA
TI
ON
A
ND
/O
R
TA
PE
RE
D
ED
GE
S
TR
IP
T O
RE
SU
LT
IN
' x
8' S
UM
P
AR
EA
(T
YP
TAPERED POLYISOCYANURATE INSULATION, AND/OR TAPERED EDGE STRIP(S) AS
NECESSARY TO RESULT IN A 8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP
AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT. CONFIGURE TAPERED INSULATION
AND EDGE STRIPS T PROVIDE A CONTINUOUS SMOOTH TRANSITION BETWEEN ADJACENT
INSULATION AND THE ROOF DRAIN.
MODIFIED BITUMEN ROOF DRAIN FLASHING PLY CONSISTING OF THE SPECIFIED MODIFIED
BITUMEN BASE PLY. EXTEND FLASHING PLY 4-INCHES MINIMUM OVER COPPER FLASHING
SHEET AT ALL EDGES.
COPPER FLASHING SHEET - 30-INCH BY 30-INCH, 32 OZ. MIN. SHEET. PRIME BOTH
SIDES OF SHEET WITH ASPHALT PRIMER AND SET IN A FULL BED OF MODIFIED
BITUMEN BITUMEN FLASHING CEMENT. PEEN COPPER INTO DRAIN BOWL AS SHOWN.
EXISTING ROOF DRAIN ASSEMBLY. REMOVE CLAMPING RING AND STRAINER (IF
PRESENT) TO ALLOW FOR INSTALLATION OF ROOF DRAIN INSERT.
ROOF DRAIN INSERT. REFER TO INSERT MANUFACTURER FOR INSTALLATION
REQUIREMENTS AND RECOMMENDATIONS.
UNDERLAYMENT
NOTE: PROVIDE A 36-INCH X 36-INCH 3-COUSE STRIPPING OF FLASHING CEMENT
AND WOVEN GLASS FABRIC OVER THE INSULATION/COVER BOARD AT
THE ROOF SUMP AREA PRIOR TO INSTALLATION OF THE MODIFIED
BITUMEN BASE PLY AND OVER THE MODIFIED BITUMEN BASE PLY PRIOR
TO INSTALLATION OF THE COPPER FLASHING SHEET.
NOTE: EXTEND MODIFIED BITUMEN BASE PLY, SURFACING PLY, FLASHING PLY,
AND COPPER FLASHING SHEET UNDER CLAMPING RING AND INTO THE
ROOF DRAIN. TIGHTLY SECURE CLAMPING RING AFTER INSTALLATION OF
ROOF DRAIN FLASHING COMPONENTS.
NOTE: THE CONTRACTOR IS RESPONSIBLE FOR REPLACEMENT/REPAIR OF
BROKEN OR DAMAGED ROOF DRAIN BOLTS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR CLARITY.
c
NOTE: RAISE DRAIN INSERT FLUSH TO BE FLUSH WITH ADJACENT ROOF DECKING.
FILL IN DRAIN VOID WITH PLYWOOD SHEATHING TO MATCH EX. ADJACENT DECKING.
ROOF DRAIN INSERT FLASHING ID: 667
SCALE: NTSW1.2 ROOF TO WALL - BUR/MASONRY ID: 843
SCALE: NTS
EX. MASONRY WALL
COUNTER FLASHING. COMPRESSION
METAL W/ HEMMED EDGE
FASTENERS PER
MANUFACTURER
8" MIN.
4" MIN.
BACKER ROD AND SEALANT
GASKET FASTENER
INSULATION PER DESIGN DOCS
EXISTING SUBSTRATE
CAP FLASHING
BASE PLY
BASE FLASHING
CAP SHEET
WALL COATING PER DESIGN DOCS
CANT STRIP
ROOFING UNDERLAYMENT PER DESIGN DOCS
REGLET METAL FASTENED TO WALL
METAL ROOF EDGE - BUR ID: 657
SCALE: NTS
EX. CLADDING
NEW 2X AS REQUIRED TO MEET HT OF
NEW INSULATION, TYP.
22 GA. CONTINUOUS CLEAT FASTENED
AT 6" O.C.
PERIMETER WOOD BLOCKINGEX. SUBSTRATE
4"
MIN.
SEALANT PER MFR
ROOFING UNDERLAYMENT
PER DESIGN DOCS
INSULATION TO ALLOW
FOR SLOPE TO DRAIN 24 GA. METAL EDGE; PRIMED, SET IN
MASTIC, & FASTENED 3" O.C.
STAGGERED
NEW SHEATHING TO MATCH EX. TO
MEET HT OF NEW 2X BLOCKING
COVERBOARD PER DESIGN DOCS
6" MIN. BASE FLASHING PLY PER DESIGN
DOCS; FULLY ADHERE TO SURFACES
CAP FLASHING PLY PER DESIGN DOCS;
FULLY ADHERE TO SURFACES
EXTEND BASE PLY OVER ROOF EDGE
AND FASTEN 8" O.C.
RAISED ROOF EDGE - BUR ID:
SCALE: NTS
CAP SHEET
3-INCHES O.C. MAX.,
IN TWO STAGGERED ROWS.
PERIMETER WOOD BLOCKING
EX. SUBSTRATE
COVERBOARD PER DESIGN DOCS
ROOFING UNDERLAYMENT
PER DESIGN DOCS
INSULATION TO ALLOW
FOR SLOPE TO DRAIN
EX. CLADDING
BASE PLY
BASE FLASHING
CAP SHEET
CAP FLASHING
3-INCHES O.C. MAX.,
IN TWO STAGGERED ROWS.
SEALANT PER MFR
24 GA. SNAP-ON FASCIA METAL
22 GA. CLEAT W/ NAILS @ 3" O.C.
CANT STRIP SET
IN ADHESIVE PER
DESIGN DOCS
W1.2
WEATHERIZATION
DETAILS - ROOF
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
1 W1.3 2 3
4 5 6
7 8 9
W1.3 W1.3
W1.3W1.3W1.3
W1.3 W1.3 W1.3
ROOF EAVE NO OVERHANG - COMP ROOF/VINYL SIDING ID: 9 REV
SCALE: NTS
NEW OR EXISTING GUTTER PER DESIGN DOCS
26 GA. PREFINISHED GALVANIZED DRIP METAL TO EXTEND INTO
GUTTER 1" MIN.
2" MI
N.
ROOFING ASSEMBLY PER DESIGN DOCS
REMOVE AND REPLACE ROOFING SHINGLES AT EAVES IN ORDER
TO INSTALL ROOF VENTS & SAMF UNDER UNDERLAYMENT.
9" SAMF TO EXTEND OVER EAVE BEHIND GUTTER
LAP UNDERLAYMENT OVER DRIP EDGE
1 1 /2"
MI
N.
EXTERIOR SHEATHING PER DESIGN DOCS
WRB PER DESIGN DOCS. PROVIDE CONTINUOUS SEALANT BEAD AT
TERMINATION POINTS OF WRB FOR AIR BARRIER CONTINUITY
VINYL SIDING
MAINTAIN MIN 1/4" GAP BETWEEN T/O SIDING & FURRING
FASCIA PER DESIGN DOCS
P.T. FURRING STRIP
SHED ROOF VENT - COMP ROOF / TYPICAL SIDING ID: 768
SCALE: NTS
2"
5" M
IN
.8"
M
IN
5" MIN.
ROOFING PER DESIGN DOCS
EX. SHEATHING CUT SHEATHING PER VENT MFR TO
ALLOW AIR FLOW
SHEET METAL FLASHING W/ HEMMED EDGE SET IN SEALANT
GASKETED FASTENER PER DESIGN DOCS, SET IN SEALANT
SELF-ADHERED UNDERLAYMENT, EXTEND 8" UP WALL
AND 12" FROM WALL
VENT PER DESIGN DOCS
ROOFING UNDERLAYMENT
SIDING PER DESIGN DOCS
WRB PER DESIGN DOCS, SEAL TERMINATION PER MFR
ROOFING UNDERLAYMENT; LAP 8" MIN UP WALL SURFACE
WRB SEALED TO SAF
EX. SHEATHING
SAF OVER APRON FLASHING
1" VENT OPENING IN
SHEATHING
ROOF-TO-WALL AT GABLE - NO OVERHANG - COMP ROOF/VINYL SIDING ID: 10 REV
SCALE: NTS
EXTERIOR SHEATHING PER DESIGN DOCS
VINYL SIDING
WRB PER DESIGN DOCS
NEW OR EXISTING ROOFING ASSEMBLY PER DESIGN DOCS
MAINTAIN MIN 1/4" GAP BETWEEN T/O SIDING AND FURRING
PROVIDE CONTINUOUS SEALANT BEAD AT TERMINATION POINTS OF
WRB FOR AIR BARRIER CONTINUITY
BARGE BOARD PER DESIGN DOCS
FURRING STRIP
EXISTING
STRUCTURE
2" M
IN
NEW OR EXISTING PREFINISHED GALVANIZED "T" METAL DRIP
EDGE INSTALLED OVER UNDERLAYMENT
1 1 /2"
M
IN
UNDERLAYMENT PER DESIGN DOCS
4"
ROOF RAKE - COMP ROOF ID: 12 REV
SCALE: NTS
2"
EX. OR NEW FASCIA BOARD
NEW 26 GA. PREFINISHED GALVANIZED
"T" METAL W/ DRIP EDGE
ROOFING PER DESIGN DOCS
UNDERLAYMENT PER DESIGN DOCS
SHEATHING PER DESIGN DOCS 4"
MIN.
EX. SIDING TO REMAIN
2"
ROOF APRON FLASHING - COMP ROOF/VINYL SIDING ID: 66
SCALE: NTS
5" M
IN
.8"
M
IN
5" MIN.
ROOFING PER DESIGN DOCS
EX. SHEATHING
SHEET METAL FLASHING W/ HEMMED EDGE SET IN SEALANT
GASKETED FASTENER PER DESIGN DOCS, SET IN SEALANT
SELF-ADHERED MEMBRANE PER DESIGN DOCS
EX. SIDING, TO BE REMOVED & RESET TO ALLOW FOR
INSTALLATION OF UNDERLAYMENT AND FLASHING
EX. WRB, TO BE PULLED BACK AND RESET TO ALLOW FOR INSTALLATION
FOR ROOFING AND UNDERLAYMENT; TAPE AND SEAL ALL CUTS
ROOFING UNDERLAYMENT; LAP 8" MIN UP WALL SURFACE
WRB SEALED TO SAF
EX. SHEATHING
SAF OVER APRON FLASHING
2"
T
YP
ROOFING AND UNDERLAYMENT PER DESIGN DOCS,
UNDERLAYMENT TO ROLL UP WALL 8"
NEW OR EX. STEP FLASHING INTERWOVEN W/
SHINGLES
WEATHER RESISTIVE BARRIER OVER FLASHING W/ 2" MIN.
LAP. SEALANT BETWEEN WRB AND ROOFING
UNDERLAYMENT
12" SAMF BEHIND DIVERTER FLASHING INSTALLED IN
SHINGLE FASHION W/ WRB. BEND SAMF OUT AROUND
FASCIA AND COVER W/ "L" METAL
PUNCH-LOCKED AND SEALED KICK OUT DIVERTER
FLASHING INSERT UNDER NEW WRB ABOVE AND
OVER NEW WRB BELOW
WALL SHEATHING PER DESIGN DOCS
WRB CONTINUOUS BEHIND FASCIA
2" MIN SPACE FROM ROOF
TOP TO SIDING MATERIAL TYP.
ROOF DIVERTER FLASHING - COMP ROOF W/ TYPICAL SIDING ID: 5
SCALE: NTS
5" M
IN
"L" METAL TUCKED UNDER EAVE FLASHING AND SHINGLED
INTO SAMF AT WALL
OPEN CUT VALLEY - COMP ROOF ID: 14
SCALE: NTS
W-VALLEY PER DESIGN DOCS
CONTINUOUS SEALANT UNDER SHINGLES
EXTEND SHINGLE AT LEAST 12" BEYOND VALLEY CENTERLINE
ROOFING UNDERLAYMENT PER DESIGN DOCS, CONTINUOUS 24"
ACROSS VALLEY
CENTER FULL WIDTH ROLL (36") OF UNDERLAYMENT PER DESIGN DOCS
TRIM OFF TOP CORNER OF SHINGLES
SHINGLES TRIMMED 2" BACK FROM VALLEY CENTERLINE
2"
ROOF EAVE - COMP. ROOFING/LAP SIDING ID: 166
SCALE: NTS
NEW OR EX. EAVE VENTS PER PLANS
INSULATION DEPTH OVER WALL TO BE
GREATER THAN THE WALL THICKNESS
INSTALL BAFFLES PER DESIGN DOCS
EXISTING WALL & SIDING TO REMAIN
NEW COMPOSITION ROOFING SHINGLES PER DESIGN DOCS.
NEW ROOFING UNDERLAYMENT PER DESIGN DOCS. 2" MIN.
OVERLAPS AT HORIZ. SEAMS & 6" AT VERT. SEAMS
NEW OR EXISTING ROOF SHEATHING
STARTER COURSE W/ SEALING STRIP PER MANUFACTURER
26 GA. PRE-FINISHED DRIP METAL TO BE INSTALLED ON
PLYWOOD UNDER THE UNDERLAYMENT
REMOVE & REINSTALL/REPLACE GUTTERS
AS NEEDED TO PERFORM WORK
REMOVE & REPLACE ANY DAMAGED FASCIA BOARD AS NECESSARY
TRIM AT INSIDE CORNER - SIDING AT FOUNDATION ID:
SCALE: NTS
PRE-FINISHED SHEET METAL FLASHING - 2"x4"
BUTYL SAMF
P.T. FURRING
MOISTURE SEALANT
EZ.8 TRIM
WRB
2" MI
N.
W1.3
WEATHERIZATION
DETAILS - ROOF
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
ROOF TOP INTAKE VENT 378
SCALE: NTS
AIR FLOW
AIR
FLOW
NEW COMPOSITION ROOFING SHINGLES PER DESIGN DOCS.
INSTALL PER MANUFACTURERS INSTRUCTIONS
NEW ROOFING UNDERLAYMENT PER DESIGN DOCS. 2" MIN.
OVERLAPS AT HORIZ. SEAMS & 6" AT VERT. SEAMS
CONTRACTOR TO CUT 1" WIDE GROOVE 6-7" AWAY FROM
DRIP EDGE PER DESIGN DOCS.
EAVE VENT
1"
SAM UNDERLAYMENT INSTALLED BELOW ROOF INTAKE
VENT CURL BACK TOP EDGE AND ADHERE TO BOTTOM
EDGE OF VENT
PIPE VENT FLASHING - COMP ROOF ID: 18
SCALE: NTS
LOCATE ALL FASTENERS WITHIN 1/2" OF THE EDGE OF THE FLASHING
OPTION: USE SELF-ADHERED UNDERLAYMENT INSTALLED OVER JAMBS
AND HEAD FLANGES AND PROPERTLY SHINGLE IN TO FIELD
UNDERLAYMENT
PROVIDE CONTINUOUS BEAD OF SEALANT UNDER
ROOFING SHINGLES AT HEAD AND JAMBS
CUT SHINGLES TO FIT AROUND FLASHING TO LEAVE A 1" CHANNEL
LEAD JACK OR PRE-FLASHED PLUMBING VENT FLASHING
GASKETED FASTENERS AT EXPOSED LOCATIONS
INTERMITTENT SEALANT
BIB LAYER OF UNDERLAYMENT OVERLAPPING FLANGE 2" & TUCKED
UNDER SEAM OF UNDERLAYMENT ABOVE
HVAC EXHAUST W/ COMP ROOF ID: 50
SCALE: NTS
FOIL TAPE AT ALL JOINTS
MECHANICALLY FASTENED
(SHEET METAL SCREWS)
EXCEPT NO FASTENERS AT
DRYER VENTS (USE CLAMPS)
R-6 UNFACED INSULATION
OPTION: USE SELF-ADHERED UNDERLAYMENT INSTALLED OVER
FLANGE AT JAMBS AND HEAD AND PROPERLY SHINGLED INTO FIELD
UNDERLAYMENT
AIR SEAL AS NEEDED
VERIFY DUCTS ARE SECURELY FASTENED
& ATTACHED TO FANS
NEW OR EX. ATTIC INSULATION
NEW OR EX. ROOF SHEATHING
ROOFING UNDERLAYMENT PER DESIGN DOCS
ROOFING PER DESIGN DOCS
GASKETED FASTENER
RECONNECT EX. OR NEW DUCT TO NEW
VENT HOOD W/ FOIL FACED DUCT TAPE
STEM VENT HOOD
PROVIDE CONTINUOUS BEAD OF SEALANT UNDER
ROOFING SHINGLES AT HEAD AND JAMBS
BIB LAYER OF UNDERLAYMENT TO LAP OVER VENT
HOOD FLANGE AT HEAD & TUCK UNDER SEAM OF
UNDERLAYMENT ABOVE
INTERMITTENT SEALANT
FURNACE EXHAUST - COMP ROOF ID: 95
SCALE: NTS
NEW OR EX. ROOF SHEATHING
NEW OR EX. ATTIC INSULATION
MAINTAIN 1" CLEARANCE TO
WOOD SHEATHING AND FRAMING
VERIFY DUCTS ARE SECURELY
FASTENED & ATTACHED TO FANS
SEALANT AT STORM COLLAR
RE-CONNECT EXISTING OR NEW DUCT TO
NEW VENT HOOD W/ SUPPORT CLAMP
STORM COLLAR FLASHING CONE
MECHANICALLY FASTENED
GASKETED FASTENER
INTERMITTENT SEALANT UNDER SHINGLES AT
SILL OPTIONAL FOR LOWER SLOPE ROOFS
ROOFING PER DESIGN DOCS
ROOFING UNDERLAYMENT PER DESIGN DOCS
AIR SEAL AS NEEDED
BIB LAYER OF UNDERLAYMENT
TO LAP OVER VENT HOOD
FLANGE AT HEAD & TUCK
UNDER SEAM OF
UNDERLAYMENT ABOVE
PROVIDE CONTINUOUS
BEAD OF SEALANT UNDER
ROOFING SHINGLES AT
HEAD AND JAMBS
ALTERNATE TO SEALANT: USE
SELF ADHERED
UNDERLAYMENT INSTALLED
OVER VENT FLANGE ON JAMBS
AND HEAD AND PROPERLY
SHINGLED INTO FIELD
UNDERLAYMENT
ATTIC VENT (BOX VENT) - COMP ROOF ID: 100
SCALE: NTS
1" DRAINAGE CHANNEL AROUND VENT
CONTINUOUS BEAD OF SEALANT UNDER ROOFING
SHINGLES AT HEAD AND JAMBS
METAL EXHAUST VENT PER DESIGN DOCS
SHEATHING CUTOUT TO ALIGN WITH VENT;
SIZE TO BE GREATER THAN VENT NFVA
EXHAUST
AIR
FLOW
NEW OR EX. ROOF SHEATHING
GASKETED FASTENERS
ROOFING UNDERLAYMENT AND SHINGLES UNDER SILL FLANGE
SAF TARGET FLASHING INSTALLED PRIOR TO VENT
INTERMITTENT SEALANT AT SILL OPTIONAL FOR LOWER SLOPE ROOFS
ALTERNATE TO SEALANT: USE SELF-ADHERED UNDERLAYMENT INSTALLED OVER VENT
FLANGE AT JAMBS AND HEAD AND PROPERLY SHINGLED IN TO FIELD UNDERLAYMENT
UNDERLAYMENT PER DESIGN DOCS
BAFFLES 2" MIN. GAP BETWEEN
INSULATION AND OPENING
1 W1.4 2 3
4 5 6
W1.4
W1.4
W1.4
W1.4W1.4
W1.4
RIDGE VENT - COMP ROOF ID: 51
SCALE: NTS
1 1/2"
AIR
FLOW
EXHAUST
HAND NAIL 3" RINGSHANK, GASKETED
WHERE EXPOSED
CONTINUOUS SHINGLE RIDGE CAP
CONTINUOUS RIDGE VENT
ROOFING SHINGLES PER DESIGN DOCS
SHEATHING PER DESIGN DOCS
UNDERLAYMENT PER DESIGN DOCS
SINGLE SLOPE ROOF CAP - COMP. ROOFING/LAP SIDING SCALE: NTS
EXISTING
STRUCTURE
6"
4"
ROOF DECK SHEATHING. NOTIFY J2 OF ANY DAMAGE, &
REPLACE AS NECESSARY. MATCH EXISTING THICKNESS
NEW OR EXISTING COMPOSITION SHINGLE
ROOF OVER #30 ROOFING FELT
WRAP ROOFING PAPER OVER VERT. LEGS
TYPICAL AT TOP CAP & GABLE ENDS.
PREFINISHED METAL CAP FLASHING.
MIN. 24 GA. SNAP FIT OVER CLEAT
CONTINUOUS GALV. METAL CLEAT. MIN. 24 GA.
EX. OR NEW FASCIA
EX CLADDING
W1.4
WEATHERIZATION
DETAILS - ROOF
Sheet Title:
Project Title:
Scale: As Noted
5202601
Issue Date:
Job #:
02/22/2022 Sheet Number:
NOTES:
1. CONTRACTOR IS RESPONSIBLE
FOR FIELD VERIFICATION OF
SIZING AND QUANTITIES OF ALL
COMPONENTS.
2. MOCK UP REVIEW OF ALL
EXTERIOR ASSEMBLIES
REQUIRED BEFORE INSTALLATION.
3. DRAWINGS ARE DIAGRAMMATIC
ONLY AND ARE NOT TO BE USED
FOR TAKE OFF QUANTITIES.
Copyright ã 2021 All rights reserved.
J2 Building Consultants, Inc.
Revisions:
DescriptionDate#
BID SET
4504 S Corbett Ave., Suite 100 Portland, Oregon 97239
Tel 503.546.8212 Fax 503.546.8219 www.J2Consultants.com
PLEASANT
VALLEY
ELEMENTARY
PRELIMINARY
Drawn By:
Checked By:
JR
REP
Project #:
CENTENNIAL
SCHOOL
| Sheets and Views |
| A0.1 TITLE, ROOF PLANS_PLEASANT_VALLEY-TITLE SHEET A0.1 |
| A0.1 TITLE, ROOF PLANS_PLEASANT_VALLEY-A1.1 |
| A0.1 TITLE, ROOF PLANS_PLEASANT_VALLEY-A1.2 |
| W SHEETS - PV ELEMENTARY-W1.1 |
| W SHEETS - PV ELEMENTARY-W1.2 |
| W SHEETS - PV ELEMENTARY-W1.3 |
| W SHEETS - PV ELEMENTARY-W1.4 |
File details come from the government source that posted it. Updated .