CRSAW (-0609).pdf
PDF 99 KB Posted
- Attached to
- Repair Position Indicator Federal contract opportunity
- Solicitation number
- FA8117-22-R-0015
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA811722R0015.pdf | ||
| 3454992_ATTACH.pdf | ||
| 3454963_ATTACH.pdf | ||
| 3456046_PWS.pdf | ||
| CRSAW (-2759).pdf | ||
| 3456207_ATTACH.pdf | ||
| 3454962_ATTACH.pdf | ||
| 3454591_CDRL1_REPORT.pdf | ||
| 3454981_ATTACH.pdf | ||
| 3454969_ATTACH.pdf | ||
| 3454991_ATTACH.pdf | ||
| 3454977_ATTACH.pdf | ||
| 3454986_ATTACH.pdf | ||
| 3456213_TRNSPDATA_REPORT.pdf | ||
| 3456212_PKGRQMT_REPORT.pdf | ||
| 3454958_ATTACH.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
PART I (To be completed by PMS Seller)
1. FORM INITIATION DATE
23 FEB 2022
2. FORM PRIORITY
3. NSN
6610002420609
4. PART NUMBER
EA308-1
5. PART NUMBER CAGE CODE
89305
6. NOUN
INDICATOR,POSITION
7. ANNUAL REPAIR
QUANTITY
8. LATEST REPAIR COST
$295.0000
9. ANNUAL REPAIR
BUDGET VALUE
$7,375.00
10. FORECAST UNIT
PRICE
$512.3600
11. ERRC
T
12. WEAPON SYSTEM
KC-135
13. END ITEM APPLICATION
14. HISTORY
DOES ORGANIC REPAIR OR DMISA REPAIR CAPABILITY CURRENTLY EXIST? X NO YES (if yes, specify SOR)
HAS THE ITEM PREVIOUSLY BEEN CONTRACT REPAIRED?
IF YES, COMPLETE TABLE BELOW FOR LAST 5 YEARS (not to exceed last 3 contracts)
NO X YES
SOURCE NAME CAGE CONTRACT NUMBER AWARD DATE
AIRTRONICS, LLC 27 DEC 202158078 FA811722F0037
AIRTRONICS, LLC 01 MAR 202158078 FA811721F0069
AIRTRONICS, LLC 26 AUG 202058078 FA811720F0224
AIRTRONICS, LLC 18 APR 202058078 FA811720F0164
AIRTRONICS, LLC 04 MAR 202058078 FA811720F0106
15. PMS SELLER NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART II (To be completed by Equipment Specialist)
16. TECHNICAL ORDERS REQUIRED NO YES (annotate required data and availability on RDL) X UNKNOWN
17. OTHER SPECIFICATIONS / SPECIAL REPAIR CRITERIA REQUIRED X NO YES (annotate required data and availability on RDL) UNKNOWN
18. THE DATA LISTED IN RDL COMPLETED SPECIFIES THE REPAIR REQUIREMENTS OR
X ADDITIONAL DATA IS REQUIRED (Coordinate with the engineer and screening office to determine information required. Document in Block 33)
19. SPECIAL TOOL / SPECIAL TEST EQUIPMENT IS NOT REQUIRED X REQUIRED REQUIRED BUT NOT AVAILABLE
SPECIAL FACILITIES ARE X NOT REQUIRED REQUIRED
GOVERNMENT FURNISHED MATERIAL IS X NOT REQUIRED REQUIRED REQUIRED BUT NOT AVAILABLE
20. EQUIPMENT SPECIALIST NAME
Gonterman, Gary R
CODE
DM
OFFICE SYMBOL
422 SCMS / GUMC820
PHONE
405-736-2351
COMPLETION DATE
28 FEB 2022
PART III (To be completed by Screening Technician if applicable)
21. REQUESTED ENGINEERING DATA
X LISTED AND ANNOTATED ON RDL NO DATA
22. SCREENING TECHNICIAN REMARKS
23. SCREENING TECHNICIAN NAME CODE OFFICE SYMBOL PHONE COMPLETION DATE
PART IV (To be completed by the Engineer)
24. CRITICAL SAFETY ITEM
X NO YES
25. CAN THIS ITEM BE COMMERCIALLY
OVERHAULED / REPAIRED (FAR Part 12)
NO X YES
26. PRECONTRACT QUALIFICATION
REQUIRED
NO X YES (JQR/QR, SQS, Waiver)
27. RDL REQUIRED FOR
SOLICITATION
NO X YES
28. RMC / RMSC CODE
R1 / C
29. RMC / RMSC EXPIRATION DATE
24 JUL 2027
30. REASON FOR OTHER THAN G CODE AND ACTION TO REMEDY
This item is subject to the RQR-848 approved on 19 June 2017 (valid through 19 June 2024).
The item is flight critical/mission essential and the government design control activity requires source approval.
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
Page 1 of 2AFMC FORM 762, 20060201, V1 Version 6Generated by PRPS using Jasper Reports on 24 Mar 2022
CONTRACT REPAIR SCREENING ANALYSIS WORKSHEET
31. APPROVED / POTENTIAL SOURCES
CAGE
CODE DATE APPROVED
Aero-labs, Inc 8N273 14 MAR 2017 Aerospace Instrument Support Inc 1UMC1 28 FEB 2002 Air Shunt Instrumnet Inc 1Y821 22 JUN 2010 Airtronics Inc 58078 08 NOV 2001
SIMMONDS PRECISION PRODUCTS, INC. 89305
William P Strube Inc 54034 08 NOV 2001
32. ENGINEER NAME
Dao, Dat T
CODE
N/A
OFFICE SYMBOL
422 SCMS / GUEAA
PHONE
405-582-5337
COMPLETION DATE
03 MAR 2022
PART V (Miscellaneous, if needed)
33. REMARKS (Remarks require Functional Responsibility / Name / Office Symbol / Phone)
USER TYPE: Engineer NAME: Dao, Dat T DATE: 24 JAN 2014
ORG / OFFICE SYMBOL: 422 SCMS / GUEA COMMERCIAL PHONE: 405-736-3961 DSN PHONE: 336-3961
The following is required: Government Source Inspection (GSI), Configuration Control (Class I and Class II Change approval), and in-plant DCMC contract administration.
The Initial Product Evaludation (IPE) is required if approved source has never repaired this item before.
USER TYPE: Equipment Specialist NAME: Malacane, Rob DATE: 17 JUN 2013
ORG / OFFICE SYMBOL: 422 SCMS / GUMC COMMERCIAL PHONE: 405-736-2571 DSN PHONE: 336-2571
5P3-3-6-13 and 5P3-3-6-14
Page 2 of 2AFMC FORM 762, 20060201, V1 Version 6Generated by PRPS using Jasper Reports on 24 Mar 2022