CPSD Land Lab Restrooms Siteprep IFC Set 2024-05-29.pdf
PDF 17 MB Posted
- Attached to
- ITB-24-01 Land Lab Restroom Site Preparation
- Solicitation number
- S-P15005-00010360
- Issued by
- Jackson County, Cheshire CDP, Oregon
About this file
The document provided is an Invitation to Bid (ITB) issued by Jackson County, Oregon for the CPSD Land Lab Restroom Building Site Preparation project. The County is seeking bids from qualified contractors to provide all labor, materials, and equipment required for sitework, infrastructure, and utilities to accommodate the installation of a prefabricated restroom building at the Central Point Land Lab site. The work includes site preparation, sidewalks, boot wash, and RV pad with utility connections. A mandatory pre-bid meeting will be held on May 22, 2024, and bids are due by June 6, 2024 at 2:00 PM PT. The County plans to award the contract by June 12, 2024 and issue a notice to proceed by June 19, 2024. The project is expected to be substantially completed by August 30, 2024. The contract will be awarded to the lowest responsible, responsive bidder based on the County's project budget. Bidders must meet certain prequalification criteria and will be required to provide performance and payment bonds, as well as comply with Oregon prevailing wage laws.
The bid documents do not specify any set-aside designations or restrictions on the types of organizations that can respond. The incumbent vendor or current contractor is not provided. The total award value or budget range for this project is also not included in the information provided.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C0.0
COVER
SHEET
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
dw g
La st S av e:
M ay
8, 5:
P
M lo t D at e:
M ay
9, :2
AM
B y:
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
below.
R
Know what's Call before you dig.
VICINITY MAP
C0.0 COVER SHEET
C1.0 EXISTING CONDITIONS
C3.0 CIVIL SITE PLAN
C4.0 GRADING PLAN
C5.0 SITE UTILITY PLAN
C6.0 CTX DETAILS
C6.1 PROJECT DETAILS
NOT TO SCALE
OWNER
CENTRAL POINT SCHOOL
DISTRICT NO. 6
300 ASH STREET
CENTRAL POINT, OR 97502
LAND SURVEYOR
PARIANI LAND SURVEYING
P.O. BOX 551
SHADY COVE, OR 97539
(541) 890-1131
NATURAL GAS COMPANY
AVISTA UTILITY
580 BUSINESS PARK DR.
MEDFORD, OR 97504
(800) 227-9187
WATER DEPARTMENT
CITY OF CENTRAL POINT
PUBLIC WORKS DEPARTMENT
140 SO. 3RD STREET
CENTRAL POINT, OR 97502
(541) 664-3321
SEWER & STORM
RVSS
NICK BAKKE, P.E.
138 W. VILAS ROAD
CENTRAL POINT, OR 97502
(541) 779-4140
CIVIL ENGINEER
POWELL ENGINEERING AND CONSULTING
TODD POWELL, P.E.
100 E. MAIN ST. SUITE O
MEDFORD, OR 97501
(541) 613-0723
ELECTRIC COMPANY
PACIFIC POWER & ELECTRIC
920 S. GRAPE ST.
MEDFORD, OR 97501
(541) 773-7751
TELEPHONE COMPANY
CENTURYLINK
150 W. STEWART AVENUE
MEDFORD, OR 97501
(541) 414-3007
RESTROOM PREFABS
CXT, AN L.B. FOSTER COMPANY
606 N. PINES ROAD, SUITE 202
SPOKANE VALLEY, WA 99206
(800) 696-5766
CONTACT INFO:
PROJECT OVERVIEW
SCALE: 1" = 20' - 0"
DRAWING INDEX:
OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED
BY THE OREGON UTILITY NOTIFICATION CENTER. THOSE
RULES ARE SET FORTH IN OAR 952-001-0010 THROUGH OAR
952-001-0090. YOU MAY OBTAIN COPIES OF THESE RULES
FROM THE CENTER BY CALLING 1-800-522-2404. IF YOU HAVE
ANY QUESTIONS ABOUT THE RULES, YOU MAY CONTACT THE
CENTER. YOU MUST NOTIFY THE CENTER AT LEAST TWO
BUSINESS DAYS, BEFORE COMMENCING AN EXCAVATION.
EXISTING UNDERGROUND UTILITIES ILLUSTRATED IN
THESE PLANS ARE APPROXIMATED BASED ON MAPS
OBTAINED FROM THE CITY OF CENTRAL POINT PUBLIC
WORKS DEPARTMENT, OR HAVE BEEN LOCATED BY A
UTILITY LOCATE COMPANY. LAYOUT INDICATED IS NOT
TO BE RELIED ON AS BEING EXACT OR COMPLETE. ALL
LINES WITHIN PROJECTED WORK ZONE SHALL BE FIELD
VERIFIED AS REQUIRED PRIOR TO CONSTRUCTION.
UTILITY STATEMENT:
CONTRACTOR SHALL OBTAIN A
BUILDING PERMIT FOR PRIVATE
UTILITY CONSTRUCTION.
PRIVATE IMPROVEMENT PLANS
FOR
CENTRAL POINT SCHOOL DISTRICT
LAND LAB RESTROOM
LOCATED IN:
SECTION 34, T.36S, R2W, W.M.
TAX LOT 2200
JACKSON COUNTY, OREGON
LOCATION MAP
NOT TO SCALE
PROJECT
LOCATION
EX. BUILDINGS
NEW CONCRETE WALK
EX. CONCRETE WALK
EX. GRAVEL LOT
NEW GRAVEL RV PAD
NEW BOOT WASH STATION
NEW
RESTROOM
C1.0
EXISTING
CONDITIONS
SURVEY NOTES
1) TOPOGRAPHIC MAP SHOWN AS A
REFERENCE ONLY.
2) CONTACT PARIANI LAND SURVEYING FOR
ADDITIONAL INFORMATION.
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
8, 5:
t D at e:
M ay
9, :2
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
C6.1
0 10 20
1" = 10'
C3.0
CIVIL SITE
PLAN
PLAN VIEW - CIVIL SITE PLAN
SCALE: 1" = 10' - 0" (24x36)
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
8, 5:
t D at e:
M ay
9, :2
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
NEW CXT "SANTIAGO"
PREFABRICATED FLUSH RESTROOM
CONCRETE WALK (TYP)
5'
REMOVE (4)
EX. BARRICADES
5'
12.75'
20'
60'
20'
GRAVEL RV PAD
GENERAL NOTES
1. BUILDING PLANS BY OTHERS. SHOWN FOR
REFERENCE ON C6.0.
5'
5'
RESTROOM BLDG
BOOT WASH STATION
5'
5'
EX. CONCRETE WALKS
EX. CONCRETE WALKS
30'
26'
S-03 C6.0
EX. DECORATIVE ART
BF
C4.0
GRADING &
E.C. PLAN
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
8, 5:
t D at e:
M ay
9, :2
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
0 10 20
1" = 10'
PLAN VIEW - GRADING AND EROSION CONTROL PLAN
SCALE: 1" = 10' - 0" (24x36)
1231.92 EOC
1231.46 EG
FF ELEV = 1232.00
1231.92 EOC
1231.56 EG
1232.03 EOG
1232.03 EG
1231.86 EOG
1231.86 EG
1231.90 EOG
1231.90 EG
1232.06
EOC/ME
1232.28
EOC/ME
1231.92
EOC 1231.92
EOG/ME
MATCH EXISTING
SIDEWALK ELEVATIONS
1231.92
EOC
MATCH EXISTING
GRAVEL LOT
1231.98
EOC
1231.92
EOC
1231.94
EOC
1232.01
EOC
RE = 1231.85
BF
C5.0
SITE UTILITY
PLAN
KEYNOTES
GENERAL NOTES
1. BUILDING PLANS BY OTHERS. SHOWN FOR
REFERENCE ON C6.0.
2. SITE ELECTRICAL SHOWN AS REFERENCE ONLY.
CONTRACTOR TO COORDINATE ALL ELECTRICAL
WORK WITH ELECTRIC INSTALLER AND PPL.
EXISTING UNDERGROUND UTILITIES ILLUSTRATED IN THESE PLANS ARE
APPROXIMATED BASED ON MAPS OBTAINED FROM THE CITY OF CENTRAL
POINT PUBLIC WORKS, OR HAVE BEEN LOCATED BY A UTILITY LOCATE
COMPANY. LAYOUT INDICATED IS NOT TO BE RELIED ON AS BEING EXACT
OR COMPLETE. ALL LINES WITHIN PROJECTED WORK ZONE SHALL BE
FIELD VERIFIED AS REQUIRED PRIOR TO CONSTRUCTION.
UTILITY STATEMENT:
STATE OF OREGON APPROVED BACKFLOW DEVICE. TESTING
SHALL BE COMPLETED BY AN OREGON CERTIFIED BACKFLOW
ASSEMBLY TESTER.
CITY TO INSTALL 2" WATER SERVICE CONNECTION WITH 1.5"
WATER METER. CONTRACTOR TO PROVIDE EXCAVATION,
BACKFILL, AND SETTING METER TO GRADE.
C6.1
PRIMARY POWER FEED TO BUILDING (SEE ELEC).
CONTRACTOR TO COORDINATE WITH PP&L ON SERVICE FEEDS
TO BUILDING.
SANITARY SEWER CLEANOUT 6-4
C6.1
4" PVC SEWER LATERAL AT 2% MIN. SLOPE
2" DOMESTIC WATER MAIN CONNECTION AT BUILDING
WITH SHUT OFF VALVE.506
RV DUMP545
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
9, :2 t D at e:
M ay
9, 4:
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
0 10 20
1" = 10'
PLAN VIEW - SITE UTILITY PLAN
SCALE: 1" = 10' - 0" (24x36)
EX. SANITARY SEWER
EX. GAS LINE
EX. OVERHEAD POWER LINE
TO BE REMOVED
NEW UNDERGROUND POWER TO RESTROOM BUILDING.
TO BE INSTALLED 30" BELOW GRADE IN 12" WIDE TRENCH.
EX. WATER SPIGOT
(TYP)
EX. FIRE HYDRANT
EX. IRRIGATION
(TYP)
RV ELECTRIC CONNECTION
(4x4 PT POST WITH RV PLUG)
EXTERIOR HOSE BIB
AND DRINKING FOUNTAIN
EX. OVERHEAD TEL. LINE
(IE ~ 1229.00)
5-6 C6.1
EX. 6" WATER LINE
4" SEWER TAP INTO EXISTING SEWER LINE.
CONTRACTOR TO FIELD VERIFY EXACT LOCATION
AND DEPTH PRIOR TO CONSTRUCTION.
RESTROOM BLDG
FF ELEV = 1232.00
5-1 C6.1
5-2 C6.1
NYLOPLAST OR APROVED EQUAL
8" AREA DRAIN BASIN WITH 12" SUMP546
"DS = DOWNSPOUT"
PIPE DISCHARGE TO RIP RAP PAD
(CONTRACTOR TO FIELD VERIFY EXACT
LOCATION FOR DISCHARGE BASED ON
EXISTING FIELD CONDITIONS)
DS
DS
WOODFORD FROST PROOF YARD HYDRANT WITH MIN. 2' BURY.
PROVIDE MINIMUM 24" CLEAR FROM BOTTOM OF HYDRANT TO
FINISHED GRADE. SECURE TO 4x4 PT POST IF NECESSARY FOR
STABILITY. EQUIVALENT MANUFACTURER ACCEPTABLE UPON
ENGINEER/DISTRICT APPROVAL.
C6.1
NEW UNDERGROUND POWER CONDUIT TO EX. CLASSROOM.
TO BE INSTALLED 30" BELOW GRADE IN 12" WIDE TRENCH.
RE = 1231.85
IE = 1230.85
4" PVC
DRAINAGE
PIPE
EX. POWER POLE
TO BE REMOVED
EX. POWER POLE
(IE ~ 1229.60)
400A ELECTRIC METER
(4x4 PT POST)
C6.0
CTX
DETAILS
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
8, 5:
t D at e:
M ay
9, :2
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
PROJECT
DETAILS
R
EV
IS
IO
N D
ES
C
R
IP
TI
O
N D
AT
E
DRAWN BY:
DESIGNED BY:
VERIFY SCALES
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
ORIGINAL DRAWING
BAR IS ONE INCH
D ra w in g N am e:
S :\P
EC
S ha re d
- D oc um en ts
\A ll
St af f\P ro je ct s\ C ur re nt P ro je ct s\
JC
SD
La nd L ab \D ra w in gs
\C
AD
D \L an d
La b
C 1-
C 6.
S av e:
M ay
8, 5:
t D at e:
M ay
9, :2
M im i F uc in i
MRF
MRF
100 E. Main St., Suite O Medford, OR 97501
541.613.0723 phone www.powellengineeringconsulting.com
JOB NO.
24-007
ISSUE DATE:
IFC SET
05/29/24
N O
CHECKED BY: TDP
COPYRIGHT © 2024 Powell Engineering and Consulting, LLC. This document, and the ideas and designs incorporated herein, as an instrument of professional service, shall remain the property of Powell Engineering and Consulting, and is not to be reproduced, published, or used in whole or in part, for any other project or purpose without the express written authorization of Powell Engineering and Consulting, LLC.
C E
N T
R A
L P
O
IN
T S
C H
O O
L D
IS
T
R
IC
T L
A N
D L
A B
R E
S T
R O
O M
M A
P
-2 W
-3 5, T A
X
LO
T
U
PT
O
N R
D , C
EN
TR
A L
PO
IN
T, O
R
SEC.34, T.36S., R2W., W.M. JACKSON COUNTY, OREGON
1. CONCRETE SHALL BE 3000 PSI MIN., 5" SLUMP (MAX.).
2. COMPACT SUBGRADE AND AGGREGATE TO 95% OF MAXIMUM DRY DENSITY.
3. FINISH SHALL BE MEDIUM BROOM PERPENDICULAR TO PEDESTRIAN TRAFFIC
UNLESS OTHERWISE DIRECTED.
4. CROSS SLOPE OF SIDEWALK SHALL BE 1.5% AWAY FROM THE BUILDING.
4" ~ 3,000 PSI CONCRETE
6" MIN. 3 4"-0"
CRUSHED AGGREGATE
EXPANSION JOINT AT
25-FT O.C. (TYP)PER PLAN
5'-0"
PREFABRICATED
BUILDING EDGE
EXPANSION JOINT AT
BUILDING EDGE (TYP)
CONTRACTION
JOINT AT 5-FT O.C.
(TYP)
EDGE OF CONCRETE
VERTICAL ELEMENT
(WHERE APPLIES)
EXPANSION
JOINT AT
BUILDING EDGE
(TYP)
EX. GRAVEL PARKING LOT
(WHERE APPLIES)
NOTES
SCALE: NTS
CONCRETE WALKS310
1. PROVIDE A MINIMUM 8' TRANSITION SECTION WHEN JOINING CURBS OF
DIFFERENT CROSS SECTIONS.
2. CONCRETE SHALL NOT BE PLACED UNTIL FORMS HAVE BEEN INSPECTED
AND APPROVED.
3. CONCRETE SHALL BE COMMERCIAL GRADE RETAINING THE FOLLOWING
CHARACTERISTICS: ENTRAINED AIR – 4.0% TO 7.0%; SLUMP – 5 INCHES OR
LESS; COMPRESSIVE STRENGTH – MINIMUM 3,300 PSI AT 28 DAYS;
TEMPERATURE – MINIMUM 50°F TO MAXIMUM 90°F.
4. ALL CONCRETE STRUCTURES REINFORCED WITH REBAR SHALL BE
VIBRATED TO REMOVE VOIDS.
5. SURFACE SHALL HAVE A FINISHED TEXTURE THAT WILL NOT BE SLICK
WHEN WET (MEDIUM BROOM FINISH). CURING COMPOUND MAY BE APPLIED
IMMEDIATELY AFTER CONCRETE IS FINISHED. WHITE PIGMENT
RECOMMENDED, CLEAR ACCEPTABLE.
6. AN EDGING TOOL SHALL BE USED ON ALL EDGES AND JOINTS.
7. PROVIDE CONTRACTION JOINTS AT 15’ INTERVALS AND “DUMMY” TOOLED
JOINTS AT 5’ INTERVALS ON CURBS, SIDEWALKS AND APPROACHES.
CONTRACTION JOINT GROOVES SHALL BE AT MINIMUM, 1 ½” DEEP OR
ONE-THIRD THE THICKNESS OF THE CONCRETE.
8. PROVIDE EXPANSION JOINTS OPPOSITE ABUTTING EXPANSION JOINTS IN
ABUTTING CONCRETE, AT EACH POINT OF TANGENCY IN THE STRUCTURE
ALIGNMENT, BETWEEN DRIVEWAYS AND CONCRETE PAVEMENT, AROUND
POLES, POSTS, BOXES AND OTHER FIXTURES WHICH PROTRUDE THROUGH
OR AGAINST THE STRUCTURES, AT ALL BCR’S AND ECR’S, AT MAXIMUM OF
100’ INTERVALS. EXPANSION JOINT MATERIAL SHALL BE OF THE
BITUMINOUS, PREFORMED FILLER TYPE NOT LESS THAN ½” WIDE, PLACED
FLUSH OR NO MORE THAN 1/8” BELOW THE CONCRETE SURFACE.
9. STRAIGHT LINE EDGES SHALL NOT VARY MORE THAN ¼” UNDER A
TWELVE-FOOT STRAIGHT EDGE.
10. CURE AND PROTECT CONCRETE AFTER PLACING AND FINISHING. KEEP
STRUCTURES FREE FROM CONTACT, STRAIN AND PUBLIC TRAFFIC FOR AT
LEAST SEVEN DAYS OR LONGER AS DIRECTED. MIXES TO EXPEDITE CURING
MAY BE USED WITH APPROVAL OF CITY ENGINEER.
11. CONCRETE SHALL BE REMOVED TO THE NEAREST CONTRACTION JOINT,
COLD JOINT OR CRACK WITHIN 4’ OF THE REPLACEMENT AREA. CONCRETE
SHALL BE SAW CUT WITH A SMOOTH, UNIFORM JOINT PROVIDED.
12. EXISTING A/C SHALL BE REMOVED/REPLACED ALONG ENTIRE CURB
SECTION TO A MINIMUM 18” WIDTH UNLESS APPROVED BY ENGINEER OF
RECORD.
CONCRETE NOTES
1. AGGREGATE BASE AND SUBBASE SHALL BE INSTALLED IN MAXIMUM 6" LIFTS AND
MECHANICALLY COMPACTED TO MINIMUM 95% OF THE MAXIMUM DENSITY IN ACCORDANCE
WITH THE AASHTO T-99 METHOD.
2. JUST PRIOR TO INSTALLING AGGREGATE BASE ROCK THE SUBGRADE SHALL BE PROOF
ROLLED. SUBGRADE MATERIAL THAT DOES NOT PASS PROOF ROLL TESTING SHALL BE
REMOVED AND ADDITIONAL CRUSHED ROCK INSTALLED.
NOTES
12" OF AGGREGATE BASE
(3/4"-0" CRUSHED ROCK)
SUBGRADE SHALL BE PROOF ROLL
TESTED PRIOR TO INSTALLING ROCK
BASE MATERIAL.
WOVEN GEOTEXTILE FABRIC
(ACF 200 WOVEN SUPPORT FABRIC,
OR EQUAL)
SCALE: NTS
GRAVEL SECTION319
| Land Lab C1-C6-C0.0 |
| C0.0 |
| Land Lab C1-C6-C1.0 |
| C1.0 |
| Land Lab C1-C6-C3.0 |
| C3.0 |
| Land Lab C1-C6-C4.0 |
| C4.0 |
| Land Lab C1-C6-C5.0 |
| C5.0 |
| Land Lab C1-C6-C6.0 |
| C6.0 |
| Land Lab C1-C6-C6.1 |
| C6.1 |