This document appears to be a set of construction drawings titled "CPQC Drawings 081524.pdf" related to a state or local government contract opportunity. The drawings likely provide technical specifications and details for a construction project, but do not contain the full scope of work, project overview, or contract details. Without the accompanying solicitation document, I cannot provide a comprehensive summary of the key contract details such as the requesting agency, project description, response due dates, award information, pricing terms, or other essential components. A full summary would require access to the complete set of contract documents to ensure I capture all the relevant details accurately and completely.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OREGON MILITARY DEPARTMENT
Camp Umatilla
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
GI-101COVER SHEET
STATE OF OREGON MILITARY DEPARTMENT
CAMP UMATILLA
CPQC RANGE CONVERSION
PROJECT #190033
VICINITY MAP PERSONNEL DRAWING INDEX
UMATILLA TRAINING SITE MANAGER
Keith Ellis 78798 Ordnance Road Hermiston, Oregon 97838
PHONE: 541-701-5573
EMAIL: keith.s.ellis2.nfg@mail.mil
RANGE CONTROL OFFICER
Oregon Training Command Captain Christopher Bassett 78798 Ordnance Road Hermiston, Oregon 97838
PHONE: (503) 867-2550
EMAIL: christopher.m.bassett2.mil@mail.mil
PROJECT MANAGER
Melissa Webber 1776 Militia Way SE Salem, Oregon 97301
PHONE 503-507-1519
EMAIL melissa.s.webber.nfg@army.mil
ELECTRICAL ENGINEER
Jon P. Farren, P.E.
Farren Engineering, Inc.
600 W. Curling Drive Boise, Idaho 83702
PHONE 208-484-5190
EMAIL jpfarren@FarrenEngineering.com
CIVIL ENGINEER
Justin Leraris, P.E.
JJ Howard, LLC 5983 W. State St., Suite D Boise, Idaho 83703
PHONE 208-846-8937
EMAIL justinl@jjhowardeng.com
The Umatilla Training Center, a.k.a. Umatilla Chemical Depot 78798 Ordnance Road Hermiston, Oregon 97838 (Exit 177 off interstate I-84)
AutoCAD SHX Text
INTERSTATE I-84
AutoCAD SHX Text
UMATILLA ARMY DEPOT
AutoCAD SHX Text
EXIT 177
AutoCAD SHX Text
EXIT 180 WESTLAND RD.
AutoCAD SHX Text
INTERSTATE I-82
AutoCAD SHX Text
COMFORT INN & SUITES
AutoCAD SHX Text
PILOT FLYING J
AutoCAD SHX Text
EXIT 182 HERMISTON LEXINGTON
AutoCAD SHX Text
SPACE AGE FUEL
AutoCAD SHX Text
EXIT 188 STANFIELD HERMISTON
AutoCAD SHX Text
THIELSEN RD.
AutoCAD SHX Text
HIGHWAY 395
AutoCAD SHX Text
STANFIELD, OREGON
AutoCAD SHX Text
HERMISTON, OREGON
AutoCAD SHX Text
HIGHWAY 207
AutoCAD SHX Text
INTERSTATE I-84
AutoCAD SHX Text
LOCATION OF PROJECT
AutoCAD SHX Text
TO UMATILLA
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
PLAN
AutoCAD SHX Text GI-101 COVER SHEET COVER SHEET SURVEY TOPOGRAPHIC SURVEY TOPOGRAPHIC SURVEY C-101 SITE GRADING PLAN SITE GRADING PLAN C-102 TARGET CONTROL POINT PLAN TARGET CONTROL POINT PLAN C-103 TARGET CONTROL POINT TABLES TARGET CONTROL POINT TABLES S-101 SITE DEMOLITION PLAN SITE DEMOLITION PLAN ES-101 ELECTRICAL SITE PLAN - NEW ELECTRICAL SITE PLAN - NEW ES-102 ELECTRICAL SITE LIGHTING PLAN ELECTRICAL SITE LIGHTING PLAN ES-103 ELECTRICAL SITE PUBLIC ADDRESS PLAN ELECTRICAL SITE PUBLIC ADDRESS PLAN ES-104 ELECTRICAL SITE DATA PLAN ELECTRICAL SITE DATA PLAN ES-105 ELECTRICAL SITE POWER PLAN OVERALL ELECTRICAL SITE POWER PLAN OVERALL ES-106 ELECTRICAL SITE POWER PLAN ELECTRICAL SITE POWER PLAN EP-101 BUILDINGS ELECTRICAL PLANS BUILDINGS ELECTRICAL PLANS EP-601 ONE LINE DIAGRAM - CONTROL TOWER ONE LINE DIAGRAM - CONTROL TOWER EP-602 PANEL SCHEDULES PANEL SCHEDULES E-501 TYPICAL LANE LAYOUT TYPICAL LANE LAYOUT E-502 SIT PRECAST COFFIN & BERM SIT PRECAST COFFIN & BERM E-503 SIT EMPLACEMENT RUBBER FLAP SIT EMPLACEMENT RUBBER FLAP E-504 SIT ELECTRICAL DETAILS SIT ELECTRICAL DETAILS E-505 RANGE MARKER DETAILS RANGE MARKER DETAILS E-506 RANGE LIGHTING DETAILS RANGE LIGHTING DETAILS E-507 DATA TERMINATION RACK DATA TERMINATION RACK E-508 DATA DIAGRAM DATA DIAGRAM E-509 ELECTRICAL SERVICE EQUIPMENT ELECTRICAL SERVICE EQUIPMENT E-510 PANELBOARD MOUNTING FRAMEPANELBOARD MOUNTING FRAME
6.
576.0
7.
577.0
8.
578.0
8.
8.
8.
578.0
579.0
9.
580.0
0.0
5.
575.5
6.
576.5
7.
577.5
7.
578.5
8.
8.
8.
579.5
9.
576.0
577.0
578.0
579.0
579.0
579.0
575.5
576.5
577.5
578.5
579.5
9.
578.5
8.
.5
578.0
578.0
578.0578.0
.0
.5
579.5
8.
7.
8.
577.0
578.0
576.5
577.5
1.
5%
1.1
1.9
1.9
2.2
2.0%
1.2%
1.1%
0.7%
1.
1%
MATCH EXISTING GRADE
AT WALK PATH
6.
577.0
578.0
579.0
5.
576.5
577.5
578.5
EXISTING TARGET BERMS TO BE
GRADED INTO FINISHED GRADE
SURFACE SHOWN
FINISHED GRADE 12 FOOT
CONTOURS
EXISTING GRADE 12 FOOT
CONTOURS
10.0%
10.0%
10.0%
ELEV: 578.67
N: 789864.56 E: 8458696.79
MATCH EG
ELEV: 576.00
N: 790018.72
E: 8458980.12
578.00
578.50
576.50
578.50
MATCH EG
579.50
MATCH EG
579.46
MATCH EG
ELEV: 578.00
N: 789993.93 E: 8458685.89
578.00
578.00
577.50
577.00
576.50
577.00
577.50
579.58
MATCH EG
579.52
MATCH EG
579.60
MATCH EG
579.31
MATCH EG
579.00
MATCH EG
578.21
MATCH EG
ELEV: 577.87
N: 789889.35
E: 8458991.03
MATCH EG
GRADING LIMITS
C-101SITE GRADING PLAN
SCALE: 1" = 10'-0"
ON 22"x34" PAPER 0' 5' 10' 20'
GRADING STATISTICS
AREA: 42,000 SF
CUT TO FILL: 260 CY
NOTES:
1. VOLUMES ARE UNADJUSTED FOR SHRINK/SWELL
2. VOLUMES DO NOT INCLUDE BERM MATERIAL OR
LEVELING COURSE FOR NEW TARGETS. SEE
COFFIN & BERM DETAIL SHEET E-502.
OREGON MILITARY DEPARTMENT
Camp Umatilla
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
GRAVEL WALK PATH
GRAVEL WALK PATH
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
EA/JPL
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
EA/JPL
8-15-24
578.0578.0
.0
.5
579.5
8.
7.
8.
577.0
578.0
576.5
577.5
6.
577.0
578.0
579.0
5.
576.5
577.5
578.5
5-1
5-2
5-3
5-4
5-5
5-6
1-1B 1-1A
1-2B 1-2A
1-3B 1-3A
1-4B 1-4A
1-5B 1-5A
1-6B 1-6A
2-2B 2-2A
2-1A2-1B
2-3A2-3B
2-4A2-4B
2-5B 2-5A
2-6A2-6B
3-1A 3-1B
3-2A3-2B
3-3A3-3B
3-4A3-4B
3-5A3-5B
3-6A3-6B
4-1A4-1B
4-2A4-2B
4-3A4-3B
4-4A4-4B
4-5A4-5B
4-6A4-6B
5-1A 5-1B
5-2A5-2B
5-3A5-3B
5-4A5-4B
5-5A5-5B
5-6A5-6B
6-1A6-1B
6-2A6-2B
6-3A6-3B
6-4A6-4B
6-5A6-5B
6-6A6-6B
7-1A 7-1B
7-2A7-2B
7-3A7-3B
7-4A7-4B
7-5A7-5B
7-6A7-6B
8-1A8-1B
8-2A8-2B
8-3A8-3B
8-4A8-4B
8-5A8-5B
8-6A8-6B
9-1A 9-1B
9-2A9-2B
9-3A9-3B
9-4A9-4B
9-5A9-5B
9-6A9-6B
10-1A 10-1B
10-2A 10-2B
10-3A10-3B
10-4A10-4B
10-5A10-5B
10-6A10-6B
1-N E 2-N
E 3-N E 4-N
E 5-N E 6-N
E 7-N E 8-N
E 9-N E 10
-N E
1-N W
-SE
1-S E 2-S
E 3-S E 4-S
E 5-S E 6-S
E 7-S E 8-S
E 9-S E
1-S W
1-1
1-2
1-3
1-4
1-5
1-6
2-1
2-2
2-3
2-4
2-5
2-6
3-1
3-2
3-3
3-4
3-5
3-6
4-1
4-2
4-3
4-4
4-5
4-6
6-1
6-2
6-3
6-4
6-5
6-6
7-1
7-2
7-3
7-4
7-5
7-6
8-1
8-2
8-3
8-4
8-5
8-6
9-1
9-2
9-3
9-4
9-5
9-6
10-1
10-2
10-3
10-4
10-5
10-6
C-102CONTROL POINT PLAN
SCALE: 1" = 10'-0"
ON 22"x34" PAPER 0' 5' 10' 20'
OREGON MILITARY DEPARTMENT
Camp Umatilla
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
NOTES:
SEE SHEET E-501 FOR TYPICAL LANE LAYOUT
SEE SHEET C-103 FOR CONTROL POINT TABLES
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
EA/JPL
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
EA/JPL
LANE 10
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
10-1A
10-1B
10-2A
10-2B
10-3A
10-3B
10-4A
10-4B
10-5A
10-5B
10-6A
10-6B
NORTHING
789926.20
789926.61
789933.73
789932.95
789947.58
789947.73
789967.94
789967.40
789981.99
789981.98
789994.06
789993.59
EASTING
8458981.98
8458979.01
8458966.54
8458963.65
8458980.20
8458977.21
8458963.68
8458960.73
8458977.31
8458974.31
8458961.48
8458958.52
ELEVATION
579.79
579.79
579.86
579.86
579.49
579.49
579.38
579.38
579.00
579.00
579.01
579.01
LANE 9
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
9-1A
9-1B
9-2A
9-2B
9-3A
9-3B
9-4A
9-4B
9-5A
9-5B
9-6A
9-6B
NORTHING
789923.14
789922.24
789931.96
789932.24
789944.27
789943.61
789966.41
789966.45
789978.52
789978.02
789992.60
789992.56
EASTING
8458937.79
8458934.93
8458951.88
8458948.89
8458936.03
8458933.10
8458948.99
8458945.99
8458933.16
8458930.20
8458946.79
8458943.79
ELEVATION
580.32
580.32
580.03
580.03
580.04
580.04
579.58
579.58
579.59
579.59
579.21
579.21
LANE 8
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
8-1A
8-1B
8-2A
8-2B
8-3A
8-3B
8-4A
8-4B
8-5A
8-5B
8-6A
8-6B
NORTHING
789921.24
789921.65
789928.77
789927.99
789942.62
789942.78
789962.98
789962.44
789977.03
789977.02
789989.10
789988.63
EASTING
8458923.13
8458920.16
8458907.70
8458904.80
8458921.36
8458918.36
8458904.83
8458901.88
8458918.46
8458915.46
8458902.63
8458899.67
ELEVATION
580.48
580.48
580.54
580.54
580.23
580.23
580.13
580.13
579.79
579.79
579.79
579.79
LANE 7
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
7-1A
7-1B
7-2A
7-2B
7-3A
7-3B
7-4A
7-4B
7-5A
7-5B
7-6A
7-6B
NORTHING
789918.18
789917.28
789927.00
789927.28
789939.31
789938.65
789961.45
789961.49
789973.56
789973.06
789987.64
789987.61
EASTING
8458878.94
8458876.08
8458893.03
8458890.04
8458877.19
8458874.26
8458890.14
8458887.14
8458874.31
8458871.35
8458887.94
8458884.94
ELEVATION
580.90
580.90
580.67
580.67
580.67
580.67
580.33
580.33
580.34
580.34
579.97
579.97
LANE 6
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
6-1A
6-1B
6-2A
6-2B
6-3A
6-3B
6-4A
6-4B
6-5A
6-5B
6-6A
6-6B
NORTHING
789916.28
789916.69
789923.81
789923.03
789937.66
789937.82
789958.02
789957.48
789972.07
789972.07
789984.14
789983.67
EASTING
8458864.29
8458861.32
8458848.85
8458845.95
8458862.51
8458859.51
8458845.98
8458843.03
8458859.62
8458856.62
8458843.79
8458840.82
ELEVATION
581.13
581.13
581.13
581.13
580.78
580.78
580.70
580.70
580.48
580.48
580.48
580.48
LANE 1
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
1-1A
1-1B
1-2A
1-2B
1-3A
1-3B
1-4A
1-4B
1-5A
1-5B
1-6A
1-6B
NORTHING
789903.30
789902.40
789912.12
789912.41
789924.43
789923.78
789946.57
789946.61
789958.68
789958.18
789972.76
789972.73
EASTING
8458702.40
8458699.54
8458716.49
8458713.50
8458700.65
8458697.72
8458713.60
8458710.60
8458697.77
8458694.81
8458711.40
8458708.40
ELEVATION
580.95
580.95
580.96
580.96
580.75
580.75
580.63
580.63
580.44
580.44
580.38
580.38
LANE 2
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
2-1A
2-1B
2-2A
2-2B
2-3A
2-3B
2-4A
2-4B
2-5A
2-5B
2-6A
2-6B
NORTHING
789906.37
789906.78
789913.89
789913.12
789927.74
789927.90
789948.10
789947.56
789962.15
789962.15
789974.22
789973.75
EASTING
8458746.59
8458743.62
8458731.16
8458728.26
8458744.82
8458741.82
8458728.29
8458725.34
8458741.92
8458738.92
8458726.09
8458723.13
ELEVATION
581.20
581.20
581.04
581.04
580.98
580.98
580.70
580.70
580.65
580.65
580.45
580.45
LANE 3
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
3-1A
3-1B
3-2A
3-2B
3-3A
3-3B
3-4A
3-4B
3-5A
3-5B
3-6A
3-6B
NORTHING
789908.26
789907.36
789917.08
789917.37
789929.39
789928.73
789951.53
789951.57
789963.64
789963.14
789977.72
789977.69
EASTING
8458761.25
8458758.39
8458775.34
8458772.35
8458759.49
8458756.56
8458772.45
8458769.45
8458756.62
8458753.66
8458770.25
8458767.25
ELEVATION
581.29
581.29
581.29
581.29
581.07
581.07
580.92
580.92
580.72
580.72
580.65
580.65
LANE 4
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
4-1A
4-1B
4-2A
4-2B
4-3A
4-3B
4-4A
4-4B
4-5A
4-5B
4-6A
4-6B
NORTHING
789911.33
789911.74
789918.85
789918.08
789932.70
789932.86
789953.06
789952.52
789967.11
789967.11
789979.18
789978.71
EASTING
8458805.44
8458802.47
8458790.00
8458787.11
8458803.66
8458800.67
8458787.14
8458784.19
8458800.77
8458797.77
8458784.94
8458781.98
ELEVATION
581.51
581.51
581.38
581.38
581.21
581.21
580.99
580.99
580.85
580.85
580.68
580.68
LANE 5
TARGET CONTROL POINTS
LANE NUMBER &
CONTROL POINT
5-1A
5-1B
5-2A
5-2B
5-3A
5-3B
5-4A
5-4B
5-5A
5-5B
5-6A
5-6B
NORTHING
789913.22
789912.32
789922.04
789922.32
789934.35
789933.69
789956.49
789956.53
789968.60
789968.10
789982.68
789982.65
EASTING
8458820.10
8458817.24
8458834.18
8458831.20
8458818.34
8458815.41
8458831.30
8458828.30
8458815.46
8458812.50
8458829.09
8458826.09
ELEVATION
581.44
581.44
581.23
581.23
581.17
581.17
580.81
580.81
580.79
580.79
580.58
580.58
LANE CORNER CONTROL POINTS
LANE CONTROL PT
1-NE
1-NW
1-SE
1-SW
2-NE
2-SE
3-NE
3-SE
4-NE
4-SE
5-NE
5-SE
NORTHING
789986.44
789983.96
789872.02
789869.54
789988.92
789874.50
789991.40
789876.98
789993.88
789879.46
789996.36
789881.94
EASTING
8458716.15
8458686.73
8458725.80
8458696.37
8458745.58
8458755.22
8458775.00
8458784.64
8458804.42
8458814.07
8458833.85
8458843.49
ELEVATION
578.00
578.00
579.21
578.55
578.08
579.56
578.15
579.51
578.15
579.57
578.10
579.38
LANE CORNER CONTROL POINTS
LANE CONTROL PT
6-NE
6-SE
7-NE
7-SE
8-NE
8-SE
9-NE
9-SE
10-NE
10-SE
NORTHING
789998.84
789884.42
790001.32
789886.90
790003.80
789889.38
790006.28
789891.86
790008.76
789894.33
EASTING
8458863.27
8458872.91
8458892.69
8458902.34
8458922.12
8458931.76
8458951.54
8458961.18
8458980.96
8458990.61
ELEVATION
577.76
579.22
577.38
578.87
576.99
578.42
576.60
578.13
576.16
577.69
C-103CONTROL POINT TABLES
OREGON MILITARY DEPARTMENT
Camp Umatilla
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
EA/JPL
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
EA/JPL
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
S-101SITE DEMOLITION PLAN
AutoCAD SHX Text
REMOVE CONCRETE PADS
AutoCAD SHX Text REMOVE ALL EXISTING PNEUMATIC TARGET MECHANISMS AND PNEUMATIC TUBING. LEVEL THE EXISTING BERM MATERIAL INTO EXISTING GRADE, REFER TO CIVIL PLANS. TYPICAL OF ALL TARGETS.
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING LIGHT POLES TO REMAIN
AutoCAD SHX Text
EXISTING LIGHT POLES TO REMAIN
AutoCAD SHX Text
AutoCAD SHX Text
REMOVE EXISTING MAGAZINE STANDS
AutoCAD SHX Text
AutoCAD SHX Text
CONTROL TOWER
AutoCAD SHX Text
STORAGE BUILDING REMOVE AIR COMPRESSOR AND PNEUMATIC CONTROLS
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
FIRE LINE
AutoCAD SHX Text
FIRE LINE
AutoCAD SHX Text
REMOVE EXISTING RANGE LIMIT MARKER
AutoCAD SHX Text
REMOVE EXISTING RANGE LIMIT MARKER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING 2" CONDUITS WITH PNEUMATIC TUBING
AutoCAD SHX Text
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 20'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text 40'
AutoCAD SHX Text
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text OBTAIN ALL LOCAL, COUNTY, STATE, AND UTILITY CONSTRUCTION PERMITS. CONTACT EACH PERMITTING AGENCY AT LEAST TWO (2) BUSINESS DAYS PRIOR TO STARTING WORK. OBTAIN ALL REQUIRED LICENSES BEFORE STARTING CONSTRUCTION. FILE FOR NOI FROM USEPA OF APPROPRIATE JURISDICTION AND PREPARE AN APPROPRIATE STORMWATER POLLUTION PREVENTION PLAN. SUBMIT APPLICATION FOR OREGON DEQ NPDES 1200-C CONSTRUCTION STORMWATER GENERAL PERMIT. INCLUDE ALL APPLICABLE FEES. LOCATIONS OF UTILITIES SHOWN ON THE DRAWINGS ARE BASED ON SITE OBSERVATIONS AND ARE NOT GUARANTEED TO BE COMPLETE OR ACCURATE. NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. MAINTAIN AND PROTECT EXISTING UTILITIES TO REMAIN IN SERVICE. PROVIDE 72 HOUR NOTICE TO OWNER FOR INTERRUPTION OF ANY UTILITIES. CONSTRUCTION SHALL BE PER THE 2018 VERSION OF THE OREGON DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR CONSTRUCTION (OSS). A COPY OF THE OSS SHALL BE KEPT ON SITE AT ALL TIMES. EMPLOY A PRIVATE UTILITY LOCATOR PRIOR TO EXCAVATION TO LOCATE ALL UTILITIES WITHIN AND ADJACENT TO THE PROJECT SITE. CONFIRM FUNCTION OF EACH DEVICE PRIOR TO DEMOLITION. ITEMS TO REMAIN SHALL BE MADE OPERATIONAL AFTER DEMOLITION IS COMPLETED. COMPLY WITH ALL FEDERAL AND STATE REGULATIONS FOR THE REMOVAL, DISPOSAL, INCINERATION AND RECYCLING OF ALL MATERIALS.
AutoCAD SHX Text C.
AutoCAD SHX Text B.
AutoCAD SHX Text A.
AutoCAD SHX Text D.
AutoCAD SHX Text E.
AutoCAD SHX Text F.
AutoCAD SHX Text G.
AutoCAD SHX Text H.
AutoCAD SHX Text I.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
REMOVE ALL EXISTING PNEUMATIC SIT TARGET MECHANISMS AND REMOVE PNEUMATIC TUBING BACK TO THE STORAGE BUILDING. CUT THE EXISTING ORANGE CONDUITS CONTAINING THE PNEUMATIC TUBING 24" BELOW GRADE AND ABANDON IN PLACE. DELIVER PNEUMATIC TARGET MECHANISMS TO THE OWNER. REFER TO CIVIL PLANS FOR LEVELING THE EXISTING BERM MATERIAL INTO EXISTING GRADE. STORAGE BUILDING: REMOVE EXISTING AIR COMPRESSOR AND AIR DRYER, DELIVER TO OWNER. REMOVE EXISTING PNEUMATIC TUBING AND ALL CONTROLS COMPONENTS AND CONTROLS WIRING. REMOVE EXISTING CONCRETE PADS WITH OLD SIGN POST BASES. ONE LOCATED LANES #1 THRU #9. LANE #10 DOES NOT HAVE ONE. ONE (1) EXISTING 2" CONDUIT WITH PNEUMATIC TUBING IN EACH LANE. ROUTES SHOWN ARE BASED ON ORIGINAL CONSTRUCTION DRAWINGS. CONTRACTOR SHALL FIELD VERIFY EXACT ROUTES. REMOVE ALL PNEUMATIC TUBING FROM THESE CONDUITS BACK TO THE STORAGE BUILDING AND CUT CONDUITS 24" BELOW GRADE AT EACH TARGET EMPLACEMENT TO ABANDON IN PLACE. TEN (10) EXISTING 2" CONDUITS CONTAINING PNEUMATIC TUBING. ONE CONDUIT FOR EACH LANE. REMOVE PNEUMATIC TUBING. CONDUITS TO BE ABANDONED IN PLACE.
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-101ELECTRICAL SITE PLAN - NEW
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
EXISTING STORAGE BUILDING
AutoCAD SHX Text
EXISTING CONTROL TOWER
AutoCAD SHX Text
NEW RANGE LIMIT MARKER
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
NEW PRECAST CONCRETE SIT COFFINS AND BERMS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LANE NUMBERS
AutoCAD SHX Text
NEW PAD MOUNTED TRANSFORMER T2 AND TWO PIPE BOLLARDS PER DETAIL 2/E-508
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
NEW RANGE LIMIT MARKER
AutoCAD SHX Text
AutoCAD SHX Text
NEW PANELBOARDS MDP AND R2 PER DETAIL 2/E-509
AutoCAD SHX Text
10 METERS
AutoCAD SHX Text
16.5 METERS
AutoCAD SHX Text
23 METERS
AutoCAD SHX Text
27 METERS
AutoCAD SHX Text
31 METERS
AutoCAD SHX Text 1-1
AutoCAD SHX Text 1-2
AutoCAD SHX Text 1-3
AutoCAD SHX Text 1-4
AutoCAD SHX Text 1-5
AutoCAD SHX Text 1-6
AutoCAD SHX Text 3-1
AutoCAD SHX Text 3-2
AutoCAD SHX Text 3-3
AutoCAD SHX Text 3-4
AutoCAD SHX Text 3-5
AutoCAD SHX Text 3-6
AutoCAD SHX Text 5-1
AutoCAD SHX Text 5-2
AutoCAD SHX Text 5-3
AutoCAD SHX Text 5-4
AutoCAD SHX Text 5-5
AutoCAD SHX Text 5-6
AutoCAD SHX Text 7-1
AutoCAD SHX Text 7-2
AutoCAD SHX Text 7-3
AutoCAD SHX Text 7-4
AutoCAD SHX Text 7-5
AutoCAD SHX Text 7-6
AutoCAD SHX Text 9-1
AutoCAD SHX Text 9-2
AutoCAD SHX Text 9-3
AutoCAD SHX Text 9-4
AutoCAD SHX Text 9-6
AutoCAD SHX Text 2-6
AutoCAD SHX Text 2-5
AutoCAD SHX Text 2-4
AutoCAD SHX Text 2-3
AutoCAD SHX Text 2-2
AutoCAD SHX Text 2-1
AutoCAD SHX Text 4-6
AutoCAD SHX Text 4-5
AutoCAD SHX Text 4-4
AutoCAD SHX Text 4-3
AutoCAD SHX Text 4-2
AutoCAD SHX Text 4-1
AutoCAD SHX Text 6-6
AutoCAD SHX Text 6-5
AutoCAD SHX Text 6-4
AutoCAD SHX Text 6-3
AutoCAD SHX Text 6-2
AutoCAD SHX Text 6-1
AutoCAD SHX Text 8-6
AutoCAD SHX Text 8-5
AutoCAD SHX Text 8-4
AutoCAD SHX Text 8-3
AutoCAD SHX Text 8-2
AutoCAD SHX Text 8-1
AutoCAD SHX Text 10-6
AutoCAD SHX Text 10-5
AutoCAD SHX Text 10-4
AutoCAD SHX Text 10-3
AutoCAD SHX Text 10-2
AutoCAD SHX Text 10-1
AutoCAD SHX Text
LANE# - TARGET#
AutoCAD SHX Text 9-5
AutoCAD SHX Text
12.5 METERS
AutoCAD SHX Text
8 METERS
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
NEW WOOD POLE
AutoCAD SHX Text
NEW GRAVEL WALK PATH
AutoCAD SHX Text
NEW ZERO TARGET BOOTS
AutoCAD SHX Text
AutoCAD SHX Text
0 METERS
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 50'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 25'
AutoCAD SHX Text 50'
AutoCAD SHX Text 100'
AutoCAD SHX Text NEW SIT TARGETS AND BERMS ORIENTED TOWARD THE FIRING POSITION. EXACT POSITION AND ROTATION OF THE TARGETS IS PER THE CONTROL POINT SCHEDULES ON ES-601. NEW ZERO TARGET BOOTS. REFER TO DETAILS.
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text FIELD SURVEY AND STAKE ALL CONTROL POINTS PER THE TABLES ON SHEET ES-601. AT COMPLETION OF CONSTRUCTION, SUBMIT AN AS-BUILT SCHEDULES OF CONTROL POINTS.
AutoCAD SHX Text A.
AutoCAD SHX Text B.
AutoCAD SHX Text
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text 1-4
AutoCAD SHX Text
LANE NUMBER TARGET NUMBER
PRECAST CONCRETE SIT TARGET EMPLACEMENT
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-102ELECTRICAL SITE
LIGHTING PLAN
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
EXISTING STORAGE BUILDING
AutoCAD SHX Text
EXISTING CONTROL TOWER
AutoCAD SHX Text
NEW RANGE LIMIT MARKER
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
NEW RANGE LIMIT MARKER
AutoCAD SHX Text
EXISTING LIGHT POLE
AutoCAD SHX Text
EXISTING WOOD POLE
AutoCAD SHX Text
EXISTING WOOD POLE
AutoCAD SHX Text
NEW WOOD POLE
AutoCAD SHX Text
OBSTRUCTION LIGHT ON RANGE LIMIT MARKER REFER TO MARKER DETAILS
AutoCAD SHX Text
OL2
AutoCAD SHX Text
OBSTRUCTION LIGHT ON RANGE LIMIT MARKER REFER TO MARKER DETAILS
AutoCAD SHX Text
OL2
AutoCAD SHX Text
AutoCAD SHX Text (6)#8-#8G-1.25"
AutoCAD SHX Text
AutoCAD SHX Text (6)#8-#8G-1.25"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text (6)#8-#8G-1.25"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text (2)#8-#8G-1"
AutoCAD SHX Text (2)#8-#8G-1"
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 50'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 25'
AutoCAD SHX Text 50'
AutoCAD SHX Text 100'
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text EXISTING WOOD POLE. REMOVE EXISTING LUMINAIRES AND PA SPEAKERS. KEEP EXISTING CONDUITS. INSTALL NEW LUMINAIRES, PA SPEAKERS, AND PULL BOXES PER THE WOOD POLE DETAIL. NEW WOOD POLE WITH LUMINAIRES AND PA SPEAKER, PER THE WOOD POLE DETAIL. HOMERUN THREE LIGHTING CIRCUITS TO EXISTING LOADCENTER T IN THE CONTROL TOWER. ROUTE THRU NEW LIGHT SWITCHES ADJACENT TO THE LOADCENTER. RED LIGHTS ON POLES = 240 VOLTS WHITE FLOOD LIGHTS ON POLES = 240 VOLTS RANGE LIMIT MARKERS RECEPTACLE AND OBSTRUCTION LIGHT = 120 VOLTS LIGHTING JUNCTION BOX. PRECAST CONCRETE, 24"x24" WITH TRAFFIC RATED GALVANIZED STEEL LID. RANGE LIMIT MARKERS: OBSTRUCTION LIGHT AND DUPLEX RECEPTACLE. BOTH ON SAME 120 VOLT CIRCUIT WITH ONE SWITCH IN THE CONTROL TOWER.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-103ELECTRICAL SITE
PUBLIC ADDRESS PLAN
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
EXISTING STORAGE BUILDING
AutoCAD SHX Text
EXISTING CONTROL TOWER
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PA CABLE-1"
AutoCAD SHX Text
PA CABLE-1"
AutoCAD SHX Text
AutoCAD SHX Text
NEW WOOD POLE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 50'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 25'
AutoCAD SHX Text 50'
AutoCAD SHX Text 100'
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
LOUDSPEAKER ON WOOD POLE
AutoCAD SHX Text
AutoCAD SHX Text EXISTING WOOD POLE. REMOVE EXISTING PA SPEAKERS. KEEP EXISTING CONDUITS. INSTALL NEW PA SPEAKERS, CABLES, AND PULL BOXES PER THE WOOD POLE DETAIL. NEW WOOD POLE WITH NEW LUMINAIRES, PA SPEAKER, AND PULL BOXES, PER THE WOOD POLE DETAIL. HOMERUN SPEAKER CABLE IN 1" CONDUIT TO THE NEW AMPLIFIER IN THE CONTROL TOWER. NEW PUBLIC ADDRESS AMPLIFIER IN THE CONTROL TOWER.
AutoCAD SHX Text
AutoCAD SHX Text
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-104ELECTRICAL SITE
DATA PLAN
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
INTERMEDIATE DATA ENCLOSURE DE-A
AutoCAD SHX Text
INTERMEDIATE DATA ENCLOSURE DE-B
AutoCAD SHX Text
INTERMEDIATE DATA ENCLOSURE DE-C
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text
WALL MOUNTED DATA PULL BOX
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATA TERMINATION RACK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-1
AutoCAD SHX Text 1-2
AutoCAD SHX Text 1-3
AutoCAD SHX Text 1-4
AutoCAD SHX Text 1-5
AutoCAD SHX Text 1-6
AutoCAD SHX Text 3-1
AutoCAD SHX Text 3-2
AutoCAD SHX Text 3-3
AutoCAD SHX Text 3-4
AutoCAD SHX Text 3-5
AutoCAD SHX Text 3-6
AutoCAD SHX Text 5-1
AutoCAD SHX Text 5-2
AutoCAD SHX Text 5-3
AutoCAD SHX Text 5-4
AutoCAD SHX Text 5-5
AutoCAD SHX Text 5-6
AutoCAD SHX Text 7-1
AutoCAD SHX Text 7-2
AutoCAD SHX Text 7-3
AutoCAD SHX Text 7-4
AutoCAD SHX Text 7-5
AutoCAD SHX Text 7-6
AutoCAD SHX Text 9-1
AutoCAD SHX Text 9-2
AutoCAD SHX Text 9-3
AutoCAD SHX Text 9-4
AutoCAD SHX Text 9-5
AutoCAD SHX Text 9-6
AutoCAD SHX Text 2-6
AutoCAD SHX Text 2-5
AutoCAD SHX Text 2-4
AutoCAD SHX Text 2-3
AutoCAD SHX Text 2-2
AutoCAD SHX Text 2-1
AutoCAD SHX Text 4-6
AutoCAD SHX Text 4-5
AutoCAD SHX Text 4-4
AutoCAD SHX Text 4-3
AutoCAD SHX Text 4-2
AutoCAD SHX Text 4-1
AutoCAD SHX Text 6-6
AutoCAD SHX Text 6-5
AutoCAD SHX Text 6-4
AutoCAD SHX Text 6-3
AutoCAD SHX Text 6-2
AutoCAD SHX Text 6-1
AutoCAD SHX Text 8-6
AutoCAD SHX Text 8-5
AutoCAD SHX Text 8-4
AutoCAD SHX Text 8-3
AutoCAD SHX Text 8-2
AutoCAD SHX Text 8-1
AutoCAD SHX Text 10-6
AutoCAD SHX Text 10-5
AutoCAD SHX Text 10-4
AutoCAD SHX Text 10-3
AutoCAD SHX Text 10-2
AutoCAD SHX Text 10-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
10 METERS
AutoCAD SHX Text
16.5 METERS
AutoCAD SHX Text
23 METERS
AutoCAD SHX Text
27 METERS
AutoCAD SHX Text
31 METERS
AutoCAD SHX Text
12.5 METERS
AutoCAD SHX Text
8 METERS
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 20'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text 40'
AutoCAD SHX Text NEW DATA TERMINATION RACK INSIDE THE STORAGE BUILDING. WALL MOUNTED DATA PULL BOX. REFER TO SHEET EP-101. INSTALL THREE (3) 2" CONDUITS FROM THE DATA TERMINATION RACK TO THE WALL MOUNTED DATA PULL BOX, ALONG WITH ONE TARGET DATA CABLE FOR EACH LANE. ONE 2" CONDUIT FROM THE WALL MOUNTED DATA PULL BOX TO THE RESPECTIVE INTERMEDIATE DATA ENCLOSURE, ALONG WITH ONE TARGET DATA CABLE FOR EACH LANE. PROVIDE A 4 FOOT SERVICE LOOP OF CABLE INSIDE THE WALL MOUNTED DATA PULL BOX. ONE 1.25" CONDUIT WITH THREE (3) TARGET DATA CABLES FROM THE INTERMEDIATE DATA ENCLOSURE TO TARGETS #1,2,3. ONE DEDICATED DATA CABLE FOR EACH TARGET. TYPICAL OF EACH LANE. ONE 1.25" CONDUIT WITH THREE (3) TARGET DATA CABLES FROM THE INTERMEDIATE DATA ENCLOSURE TO TARGETS #4,5,6. ONE DEDICATED DATA CABLE FOR EACH TARGET. TYPICAL OF EACH LANE.
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text NEW PVC CONDUIT WITH NEW TARGET DATA CABLES SUBSCRIPT AT ARROWHEAD INDICATES QUANTITY OF DATA CABLES IN THE CONDUIT
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A. POWER AND DATA CONDUITS INSTALLED IN SAME POWER AND DATA CONDUITS INSTALLED IN SAME TRENCHES. B. ROUTE TRENCHES TO ENSURE DATA CABLES DO NOT EXCEED ROUTE TRENCHES TO ENSURE DATA CABLES DO NOT EXCEED 300 FEET LENGTH.
GENERAL NOTES
ɸ
Camp Umatilla
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-105ELECTRICAL SITE
POWER PLAN - OVERALL
ɸ
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
DIRT ROAD
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
GRAVEL ROAD
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
ASPHALT ROAD
AutoCAD SHX Text
150 METERS 492.126 FEET
AutoCAD SHX Text
200 METERS 656.168 FEET
AutoCAD SHX Text
100 METERS 328.084 FEET
AutoCAD SHX Text
50 METERS 164.042 FEET
AutoCAD SHX Text
25 METERS 82.021 FEET
AutoCAD SHX Text
0 METERS 0 FEET
AutoCAD SHX Text
FIRING LINE THRU CENTER OF FOX HOLES
AutoCAD SHX Text
NEW UNDERGROUND 15 KV 1ɸ FEEDER IN 3" CONDUIT FEEDER IN 3" CONDUIT
AutoCAD SHX Text
EXISTING 15 KV SECTIONALIZING JUNCTION ENCLOSURE
AutoCAD SHX Text
ARF RIFLE RANGE
AutoCAD SHX Text
EXISTING STORAGE BUILDING
AutoCAD SHX Text
EXISTING CONTROL TOWER
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
EXISTING GRAVEL WALK PATH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LANE NUMBERS
AutoCAD SHX Text
NEW PAD MOUNTED TRANSFORMER T2 AND TWO PIPE BOLLARDS REFER TO BOLLARD DETAIL
AutoCAD SHX Text
AutoCAD SHX Text
PANELBOARD R2
AutoCAD SHX Text
PANELBOARD MDP
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 50'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 25'
AutoCAD SHX Text 50'
AutoCAD SHX Text 100'
AutoCAD SHX Text SUPPLY NEW 15 KV 1ɸ FEEDER FROM THE EXISTING 15 KV FEEDER FROM THE EXISTING 15 KV SECTIONALIZING JUNCTION ENCLOSURE. REFER TO ONE LINE DIAGRAM SHEET EP-601.
AutoCAD SHX Text A.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
PRIOR TO EXCAVATION, LOCATE ALL UTILITIES ON SITE.
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
ES-106ELECTRICAL SITE
POWER PLAN
AutoCAD SHX Text
GRAVEL
AutoCAD SHX Text
PANELBOARD A
AutoCAD SHX Text
PANELBOARD C
AutoCAD SHX Text
PANELBOARD B
AutoCAD SHX Text
PANELBOARD R2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
POWER PULL BOX TYPICAL OF (10)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
NEW PAD MOUNTED TRANSFORMER T2 AND TWO PIPE BOLLARDS REFER TO BOLLARD DETAIL
AutoCAD SHX Text INSTALL NEW UNDERGROUND 15 KV ELECTRICAL SERVICE REFERENCE ONE LINE DIAGRAM SHEET EP-601
AutoCAD SHX Text A-1(3)
AutoCAD SHX Text A-5(7)
AutoCAD SHX Text A-9(11)
AutoCAD SHX Text A-13(15)
AutoCAD SHX Text A-17(19)
AutoCAD SHX Text A-21(23)
AutoCAD SHX Text B-1(3)
AutoCAD SHX Text B-5(7)
AutoCAD SHX Text B-9(11)
AutoCAD SHX Text B-13(15)
AutoCAD SHX Text B-17(19)
AutoCAD SHX Text B-21(23)
AutoCAD SHX Text B-24(26)
AutoCAD SHX Text B-28(30)
AutoCAD SHX Text C-1(3)
AutoCAD SHX Text C-5(7)
AutoCAD SHX Text C-9(11)
AutoCAD SHX Text C-13(15)
AutoCAD SHX Text C-17(19)
AutoCAD SHX Text C-21(23)
AutoCAD SHX Text
10 METERS
AutoCAD SHX Text
16.5 METERS
AutoCAD SHX Text
23 METERS
AutoCAD SHX Text
27 METERS
AutoCAD SHX Text
31 METERS
AutoCAD SHX Text
12.5 METERS
AutoCAD SHX Text
8 METERS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1-2
AutoCAD SHX Text 1-3
AutoCAD SHX Text 1-4
AutoCAD SHX Text 1-5
AutoCAD SHX Text 1-6
AutoCAD SHX Text 3-1
AutoCAD SHX Text 3-2
AutoCAD SHX Text 3-3
AutoCAD SHX Text 3-4
AutoCAD SHX Text 3-5
AutoCAD SHX Text 3-6
AutoCAD SHX Text 5-1
AutoCAD SHX Text 5-2
AutoCAD SHX Text 5-3
AutoCAD SHX Text 5-4
AutoCAD SHX Text 5-5
AutoCAD SHX Text 5-6
AutoCAD SHX Text 7-1
AutoCAD SHX Text 7-2
AutoCAD SHX Text 7-3
AutoCAD SHX Text 7-4
AutoCAD SHX Text 7-5
AutoCAD SHX Text 7-6
AutoCAD SHX Text 9-1
AutoCAD SHX Text 9-2
AutoCAD SHX Text 9-3
AutoCAD SHX Text 9-4
AutoCAD SHX Text 9-5
AutoCAD SHX Text 9-6
AutoCAD SHX Text 2-6
AutoCAD SHX Text 2-5
AutoCAD SHX Text 2-4
AutoCAD SHX Text 2-3
AutoCAD SHX Text 2-2
AutoCAD SHX Text 2-1
AutoCAD SHX Text 4-6
AutoCAD SHX Text 4-5
AutoCAD SHX Text 4-4
AutoCAD SHX Text 4-3
AutoCAD SHX Text 4-2
AutoCAD SHX Text 4-1
AutoCAD SHX Text 6-6
AutoCAD SHX Text 6-5
AutoCAD SHX Text 6-4
AutoCAD SHX Text 6-3
AutoCAD SHX Text 6-2
AutoCAD SHX Text 6-1
AutoCAD SHX Text 8-6
AutoCAD SHX Text 8-5
AutoCAD SHX Text 8-4
AutoCAD SHX Text 8-3
AutoCAD SHX Text 8-2
AutoCAD SHX Text 8-1
AutoCAD SHX Text 10-6
AutoCAD SHX Text 10-5
AutoCAD SHX Text 10-4
AutoCAD SHX Text 10-3
AutoCAD SHX Text 10-2
AutoCAD SHX Text 10-1
AutoCAD SHX Text 1-1
AutoCAD SHX Text A-5(7)
AutoCAD SHX Text A-1(3)
AutoCAD SHX Text A-9(11)
AutoCAD SHX Text A-13(15)
AutoCAD SHX Text A-17(19)
AutoCAD SHX Text A-21(23)
AutoCAD SHX Text B-1(3)
AutoCAD SHX Text B-5(7)
AutoCAD SHX Text B-9(11)
AutoCAD SHX Text B-13(15)
AutoCAD SHX Text B-17(19)
AutoCAD SHX Text B-21(23)
AutoCAD SHX Text B-24(26)
AutoCAD SHX Text B-28(30)
AutoCAD SHX Text C-1(3)
AutoCAD SHX Text C-5(7)
AutoCAD SHX Text C-9(11)
AutoCAD SHX Text C-13(15)
AutoCAD SHX Text C-17(19)
AutoCAD SHX Text C-21(23)
AutoCAD SHX Text
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
NORTH
AutoCAD SHX Text SCALE: 1" = 20'-0" ON 22"x34" PAPER
AutoCAD SHX Text
PLAN
AutoCAD SHX Text 0'
AutoCAD SHX Text 10'
AutoCAD SHX Text 20'
AutoCAD SHX Text 40'
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text HOMERUN (3)#8-#10G-1" FROM TARGETS #1,2,3. HOMERUN (3)#6-#8G-1" FROM TARGETS #4,5,6. FEEDER FROM PANELBOARD R2. REFER TO THE ONE LINE DIAGRAM. UNDERGROUND SECONDARY FEEDER FROM NEW TRANSFORMER T3 TO NEW PANELBOARD R2, REFERENCE ONE LINE DIAGRAM SHEET EP-601.
AutoCAD SHX Text
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
AutoCAD SHX Text J
AutoCAD SHX Text A-2,4,6
AutoCAD SHX Text
HOMERUN TO PANELBOARD
AutoCAD SHX Text
EQUIPMENT GROUNDING CONDUCTOR (G)
AutoCAD SHX Text
INDIVIDUAL
AutoCAD SHX Text
CIRCUIT
AutoCAD SHX Text
UNGROUNDED CONDUCTORS
AutoCAD SHX Text
NEUTRAL (N)
AutoCAD SHX Text A. POWER AND DATA CONDUITS INSTALLED IN SAME TRENCHES. POWER AND DATA CONDUITS INSTALLED IN SAME TRENCHES. B. ALL CONDUCTORS STRANDED COPPER. ALL CONDUCTORS STRANDED COPPER. C. INSTALL PULL STRING IN ALL EMPTY CONDUITS. INSTALL PULL STRING IN ALL EMPTY CONDUITS. D. ALL CONDUITS ARE CONCEALED. EXPOSED OR SURFACE ALL CONDUITS ARE CONCEALED. EXPOSED OR SURFACE MOUNTED CONDUITS ONLY ALLOWED WITH WRITTEN PERMISSION FROM THE ELECTRICAL ENGINEER. E. INSTALL AN INSULATED EQUIPMENT GROUNDING CONDUCTOR INSTALL AN INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS. F. INSTALL A SEPARATE NEUTRAL CONDUCTOR FOR EACH INSTALL A SEPARATE NEUTRAL CONDUCTOR FOR EACH CIRCUIT. EDISON CIRCUITS WITH SHARED NEUTRALS ARE NOT ALLOWED.
AutoCAD SHX Text
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
EP-101BUILDINGS ELECTRICAL PLANS
AutoCAD SHX Text
EXISTING LOADCENTER S
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING AIR COMPRESSOR & AIR DRYER
AutoCAD SHX Text
AutoCAD SHX Text
EXISTING WIREWAY, COMPRESSED AIR CONTROLS, WIRING, AND PIPING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
(10) EXISTING UNDERGROUND ORANGE 2" CONDUITS WITH PNEUMATIC TUBING. ONE CONDUIT PER LANE.
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE BUILDING
AutoCAD SHX Text
EXISTING LOADCENTER T
AutoCAD SHX Text
AutoCAD SHX Text +48"
AutoCAD SHX Text +24"
AutoCAD SHX Text
EXISTING LOADCENTER S
AutoCAD SHX Text DATA TERMINATION RACK (DTR) 22"Lx36"Wx83"H
AutoCAD SHX Text
EXISTING WIREWAY
AutoCAD SHX Text
CONTROL TOWER
AutoCAD SHX Text
STORAGE BUILDING
AutoCAD SHX Text
NEW GROUND BAR (TGB)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
UFER GROUND ENCASED IN CONCRETE
AutoCAD SHX Text
NEW PAD MOUNTED TRANSFORMER T2
AutoCAD SHX Text
PANELBOARD R2
AutoCAD SHX Text
#1/0 BARE COPPER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text S-13,15
AutoCAD SHX Text
AutoCAD SHX Text
PIPE BOLLARDS
AutoCAD SHX Text
PANELBOARD MDP
AutoCAD SHX Text
MAIN GROUNDING BUSBAR ON STEEL MOUNTING FRAME
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text S
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CONTROL TOWER
AutoCAD SHX Text
STORAGE BUILDING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DATA PULL BOX (DPB)
AutoCAD SHX Text
NEW PA SYSTEM AMPLIFIER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text DATA TERMINATION RACK (DTR) 22"Lx36"Wx83"H
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text %%uEXISTING STORAGE BUILDING PLAN
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text KEEP EXISTING LOADCENTER S AND LOADCENTER T. INSTALL NEW COPPER FEEDERS. REMOVE EXISTING AIR COMPRESSOR AND AIR DRYER. DELIVER TO OWNER. KEEP THE EXISTING 8"x8"x12' WIREWAY. AND KEEP THE TEN (10) EXISTING UNDERGROUND ORANGE 2" CONDUITS ENTERING THE BOTTOM OF THE WIREWAY. REMOVE EXISTING COMPRESSED AIR CONTROLS, WIRING, AND PIPING. REMOVE COMPRESSED AIR TUBING WITHIN THE ORANGE CONDUITS OUT TO EACH TARGET. WALL MOUNTED DATA PULL BOX. 36"Hx24"Wx12"D. WITH THREE (3) 2" CONDUITS AND DATA CABLES FROM THE DATA TERMINATION RACK TO THE INTERMEDIATE DATA ENCLOSURES. NEW TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) AND UFER GROUND. 20 FEET OF #4AWG BARE COPPER INSIDE 2" OF CONCRETE. #4 AWG BARE COPPER FROM GROUND BAR TO THE EQUIPMENT GROUNDING BUS IN EXISTING LOADCENTER S. #6 AWG BONDING CONDUCTOR FROM TGB GROUND BAR TO THE GROUNDING STRIP IN THE DATA TERMINATION RACK AND TO THE DATA JUNCTION BOX ENCLOSURE. (3) 2" CONDUITS WITH DATA CABLES BETWEEN THE DATA PULL BOX AND THE DATA TERMINATION RACK. REFER TO THE DATA DIAGRAM FOR CABLE QUANTITIES. SIX (6) CONTROL TOWER DATA CABLES (INDOOR CAT 6, PLENUM RATED) IN A 1.25" CONDUIT FROM THE DATA TERMINATION RACK TO THE CONTROL TOWER DATA PULL BOX. FIELD COORDINATE CONDUIT ROUTE AND PULL BOX LOCATION. EXTERIOR CONDUITS: EMT WITH COMPRESSION FITTINGS. SEAL ALL BUILDING PENETRATIONS WEATHER TIGHT. CONTROL TOWER DATA PULL BOX: NEMA 1, 12"x12"x6", WALL MOUNTED BELOW THE COUNTER TOP. PROVIDE A 24" SERVICE LOOP FOR EACH DATA CABLE INSIDE THIS PULL BOX. THREE (3) DATA OUTLETS BELOW COUNTER IN THE CONTROL ROOM. PROVIDE EACH OUTLET WITH (2) RJ45 PORTS, (2) DATA CABLES, AND A 1.25" CONDUIT TO THE CONTROL TOWER DATA PULL BOX. INSTALL A 1" HOLE WITH CABLE GROMMET IN THE COUNTER TOP ABOVE EACH OUTLET BOX. NEW PUBLIC ADDRESS AMPLIFIER THREE NEW LIGHT SWITCHES IN THE CONTROL TOWER: RED LIGHTS, WHITE FLOOD LIGHTS, AND RANGE LIMIT MARKERS. RED LIGHTS = 2-POLE SWITCH, RED COVERPLATE. WHITE LIGHTS = 2-POLE SWITCH, WHITE COVERPLATE WIT FLIP LID COVER TO PREVENT ACCIDENTAL SWITCHING. RANGE MARKERS = 1-POLE SWITCH, YELLOW COVERPLATE. INSTALL ONE NEW 20A/2P CIRCUIT BREAKER IN LOADCENTER T TO SUPPLY THE RED LIGHTS. TAPE LABEL EACH SWITCH WITH 1/4" TALL BLACK TEXT ON WHITE BACKGROUND.
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text %%uNEW DATA PLAN
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text
AutoCAD SHX Text %%uNEW POWER PLAN
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text DATA OUTLET AT 18" (UNO) 4-11/16" SQUARE 2 " DEEP OUTLET BOX 18" DEEP OUTLET BOX SINGLE-GANG TRIM RING & 2-PORT COVERPLATE 1" CONDUIT AND TWO CABLES TO THE CONTROL TOWER DATA PULL BOX. SUBSCRIPT INDICATES QUANTITY OF CABLES ROUTED TO THE PATCH PANEL IN THE DATA TERMINATION RACK (DTR). TERMINATE AND LABEL EACH END. COIL 48" OF SLACK CABLE AT THE DATA TERMINATION RACK.
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
CPQC Range Conversion
ENGINEERING, Inc.
E L E C T R I C A L E N G I N E E R S
FARREN
600 W. Curling Drive, Boise, Idaho 83702
PHONE (208) 484-5190
FarrenEngineering.com
EP-601ONE LINE DIAGRAM
CONTROL TOWER
ɸ
NEW ONE LINE DIAGRAM
ɸ ɸ ɸ ɸ ɸ, ɸ ɸ
EXISTING ONE LINE DIAGRAM AT BUILDINGS
NEW ONE LINE DIAGRAM AT BUILDINGS
ɸ ɸ ɸ ɸ - 3" ɸ ɸ ɸ
AutoCAD SHX Text SHEET No.
AutoCAD SHX Text
SHEET NAME
AutoCAD SHX Text
REVISION
AutoCAD SHX Text
DATE
AutoCAD SHX Text No.
AutoCAD SHX Text
DESIGNED:
AutoCAD SHX Text
DRAWN:
AutoCAD SHX Text
CHECKED:
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
JPF
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FARREN PROJECT #
AutoCAD SHX Text
15 AUGUST 2024
AutoCAD SHX Text 18006B.1
AutoCAD SHX Text
GOVERNMENT PROJECT #
AutoCAD SHX Text 190033
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text
NOTICE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
IF THIS BAR DOES NOT MEASURE 1" THEN DRAWING IS NOT TO SCALE
AutoCAD SHX Text
PANELBOARD R2 AT BASE OF CONTROL TOWER 240/120 VOLT, 1ɸ, 3 WIRE , 3 WIRE 22K AIC
AutoCAD SHX Text 400A 2P
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text
PANELBOARD A
AutoCAD SHX Text (3)3/0-#6G-2"
AutoCAD SHX Text
PANELBOARD B
AutoCAD SHX Text
PANELBOARD C
AutoCAD SHX Text MAIN GROUNDING BUSBAR GROUNDING ELECTRODE SYSTEM AT PAD MOUNTED TRANSFORMER AND PANELBOARD R2 #4 - GROUND RING AROUND TRANSFORMER #4 - UFER GROUND #4 - STEEL MOUNTING FRAME #1/0 - STEEL BULIDING STRUCTURE #4 - (2) GROUND RODS #1/0 - TO TELECOMMUNICATIONS GROUNDING BUSBAR (TGB) IN THE STORAGE BUILDING. REMOVE EXISTING ALUMINUM FEEDER CONDUCTORS. INSTALL NEW COPPER FEEDERS TO THE NEW PANELBOARD MDP AND TO THE TWO EXISTING LOADCENTERS: REUSE PORTIONS OF EXISTING CONDUITS WHERE POSSIBLE. GROUNDING AT NEW PANELBOARD MDP: #4 AWG TO THE STEEL MOUNTING FRAME AND EXISTING GROUNDING RODS. GROUNDING AT NEW PANELBOARD A, B, AND C: #4 AWG FROM THE PANELBOARD EQUIPMENT GROUND BUS TO THE STEEL MOUNTING FRAME, AND A SEPARATE #6 AWG TO THE GROUNDING STRIP INSIDE THE INTERMEDIATE DATA ENCLOSURE. INSTALL CONDUIT SEALING COMPOUND AT TOP OF THE UNDERGROUND CONDUITS AT BOTH ENDS. THIS IS TO MINIMIZE RODENTS AND HANTAVIRUS. REFER TO SPECIFICATION 26-0533 PARAGRAPH 2.5. INSTALL ENGRAVED NAMEPLATE ON PANELBOARD R2 SHOWING AVAILABLE FAULT CURRENT BASED ON INSTALLED TRANSFORMER IMPEDANCE.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
KEYNOTES
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
AutoCAD SHX Text 30A 2P
AutoCAD SHX Text
SPD
AutoCAD SHX Text
SPD
AutoCAD SHX Text 30A/2P
AutoCAD SHX Text
SPD
AutoCAD SHX Text 30A/2P
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
AutoCAD SHX Text
SPD
AutoCAD SHX Text 30A/2P
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text
AutoCAD SHX Text
NEUTRAL
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text C.
AutoCAD SHX Text B.
AutoCAD SHX Text A.
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text ALL CONDUCTORS STRANDED COPPER. PANELBOARDS SHALL BE SERIES RATED WITH THE UPSTREAM OVERCURRENT DEVICE. SUBMIT PRODUCT DATA SHOWING THE SERIES RATED COMBINATIONS. OVERCURRENT DEVICES AND ENCLOSURES SHALL BE LABELED AND IDENTIFIED AS SERIES RATED, IN ACCORDANCE WITH NEC 110-22 AND 240.86.
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
SURGE PROTECTION DEVICE
AutoCAD SHX Text
CIRCUIT BREAKER
AutoCAD SHX Text
SPD
AutoCAD SHX Text
15KV 1ɸ
AutoCAD SHX Text EXISTING 3ɸ SECTIONALIZER AT ARF RIFLE RANGE SECTIONALIZER AT ARF RIFLE RANGE 12470GRY/7200 VOLTS, 3ɸ, 4 WIRE , 4 WIRE 200 AMP BUSHINGS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text 200A 2P
AutoCAD SHX Text
1/2" TALL TEXT 1/2" BORDER AROUND TEXT
AutoCAD SHX Text
AutoCAD SHX Text %%uENGRAVED NAMEPLATES
AutoCAD SHX Text
SCALE: NONE
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text STAINLESS STEEL ENGRAVED NAMEPLATE DO NOT ABBREVIATE TEXT ALL TEXT LEFT-JUSTIFIED SPECIFICATION 26-0504
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
NAMEPLATES
AutoCAD SHX Text
AutoCAD SHX Text PAD MOUNTED…