This is a cover sheet and code compliance document for the Yankee Springs Shooting Range project, prepared by the State of Michigan's Department of Technology, Management, and Budget (DTMB) and Colliers Engineering and Design. The project is located at 10370 Gun Lake Road in Middleville, Michigan, and involves the construction of a new shooting range facility. The document is dated 04/08/2025 and includes a comprehensive code compliance diagram, building data summary, and project details for a single-story, 2,654 square foot structure with a Use Group A-3 classification.
The project will adhere to multiple Michigan and international building codes, including the Michigan Rehab Code, Michigan Building Code, International Fire Code, and various mechanical, plumbing, and electrical codes. The facility requires obtaining all necessary permits and coordinating with the local fire marshal, particularly for fire extinguisher placement. The design team includes Colliers Engineering and Design, with key personnel such as David Moss (Architect) and David Lenz (DTMB representative). The project involves civil, structural, architectural, and electrical design components, with a focus on compliance with local building and safety regulations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OCCUPANCY CLASSIFICATION':
• USE GROUP: A-3
SPRINKLED: NO
CONSTRUCTION TYPE: VB
BUILDING DATA: ACTUAL ALLOWABLE
• SQUARE FOOTAGE: 2654 SF 6000 SF
• HEIGHT: 19 FT 40'-0"
• NO. OF STORIES: 1 1
FIRE RATING (BUILDING ELEMENTS): REQUIRED PROVIDED
• STRUSTURAL FRAME: 0-HOUR 0-HOUR
• BEARING WALLS (EXTERIOR): 0-HOUR 0-HOUR
• BEARING WALLS (INTERIOR): 0-HOUR 0-HOUR
• NON BEARING WALLS (EXTERIOR): 0-HOUR 0-HOUR
• NON BEARING WALLS (INTERIOR): 0-HOUR 0-HOUR
• ROOF CONSTRUCTION: 0-HOUR 0-HOUR
MEANS OF EGRESS: REQUIRED PROVIDED
• MINIMUM NUMBER OF EXITS: 1 1
• EXIT ACCESS TRVAEL DISTANCE 200' PER PLANS
• DEAD-END LIMIT: 20' N/A
• COMMON PATH OF TRAVEL LIMIT: 30' N/A
• CORRIDOR FIRE RATING: 0-HOUR 0-HOUR
BUILDING DATA & CODE SUMMARY
1. APPLICABLE CODES:
A. CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES:
• MICHIGAN REHAB CODE FOR EXISTING BUILDINGS, 2015 EDITION
• MICHIGAN BUILDING CODE, 2015 EDITION
• ICC A117.1, 2009 EDITION
• INTERNATIONAL FIRE CODE, 2012 EDITION
• MICHIGAN MECHANICAL CODE, 2021 EDITION
• MICHIGAN PLUMBING CODE, 2021 EDITION
• NATIONAL ELECTRIC CODE, 2023 EDITION
WORK SHALL CONFORM TO FEDERAL, STATE AND LOCAL CODES AS
NTERPRETED BY THE AUTHORITY HAVING JURISDICTION.
2. COMPLIANCE:
A. PROVIDE FIRE EXTINGUISHERS IN CONFORMANCE WITH THE FIRE CODE
SECTION 906 AND COORDINATE WITH FIRE MARSHAL PRIOR TO
INSTALLATION. DO NOT INSTALL FIRE EXTINGUISHERS UNTIL LOCATIONS
HAVE BEEN REVIEWED AND APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
B. OBTAIN ALL REQUIRED PERMITS AND PAYMENT OF PERMIT AND APPLICATION
FEES FOR THE WORK.
GENERAL NOTES
TOILET ROOMS:
• ON SITE, LESS THAN 500' PER MPC 403.3.3
ENTRANCE
STORAGE
137 SF
STAGING
328 SF
7 PEOPLE
UNOCCUPIED
X75 1/2
.D
PL
YA
NK
EE
SP
RI
NG
S
SH
O O
TI
NG
RA
NG
E Y2
DA
TE
SH
EE
T
ID
EN
TI
FI
C
AT
IO
N
NO
IS
SU
ED
FO
R
G un La ke R oa d, M id dl ev ille ,M ic hi ga n
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y ,M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
A D
A M
LA
C
H ,R
A ,N
C A
R B
,D
IR
EC
TO
R
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
RV
IC
ES
A
D M
IN
IS
TR
A
TI
O
N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
FI
LE
N O
P R
EL
IM
IN
A R Y
EN
GI
NE
ER
PR
OJ
EC
T
NO
IN
D
EX
N O
FI
N A L
R
EC
O R D
C O N S
TR
U C
TI
O N
DR
AW
N
DE
SI
GN
ED
AP
PR
OV
ED
C H
EC
KE
D
P.
A.
K
D.
P.
L.
R.
E.
G.
W es t S ag in aw
H w y.
S ui te
La ns in g, M I 4 of fic e:
.8
.8 w w w .c ol lie rs en gi ne er in g.
co m D.
P.
L.
R.
E.
G.
D.
P.
L.
R.
E.
G.
G000
1-
1-
PROJECT LOCATION MAP
PROJECT CONTACT LIST DRAWING INDEX
CED PROJECT: 24003879A
YANKEE SPRINGS
SHOOTING RANGE
10370 Gun Lake Road, Middleville, Michigan 49333
STATE OF MICHIGAN
DEPARTMENT OF TECHNOLOGY,
MANAGEMENT, AND BUDGET
ARCHITECT
COLLIERS ENGINEERING AND DESIGN
DAVID MOSS, AIA
7050 WEST SAGINAW HWY. SUITE 200
LANSING, MI 48917
517.827.8672
OWNER
STATE OF MICHIGAN,
DTMB
DAVID LENZ
430 W ALLEGAN ST.
LANSING, MI 48933
DATE: 04/08/2025
SITE
CIVIL ENGINEER
COLLIERS ENGINEERING AND DESIGN
ANNIA ALVAREZ-NODARSE, PE
7050 WEST SAGINAW HWY. SUITE 200
LANSING, MI 48917
517 827 8667
ELECTRICAL ENGINEER
COLLIERS ENGINEERING AND DESIGN
ANGIE ROBINSON, PE
7050 WEST SAGINAW HWY. SUITE 200
LANSING, MI 48917
517 827 3354
SCALE : 1/16" = 1'-0"1 CODE COMPLIANCE DIAGRAM - FIRST FLOOR N
DRAWING INDEX.
AD
D
EN
D
U M
/0
8/
00 - GENERAL
G000 COVER SHEET Yes
01 - CIVIL
X100 TOPOGRAPHIC MAPPING Yes C200 SITE PLAN Yes
C300 GRADING PLAN
C310 SESC PLAN
C311 SESC DETAILS
03 - STRUCTURAL
S001 GENERAL NOTES
04 - ARCHITECTURAL
A101 FIRST FLOOR PLAN
A103 FOUNDATION PLAN
A104 ROOF PLAN
A201 EXTERIOR ELEVATIONS
A301 BUILDING SECTIONS
A501 ENLARGED PLAN DETAILS
A521 SECTION DETAILS
A522 SECTION DETAILS
08 - ELECTRICAL
E001 LEGEND
ES001 SITE POWER PLAN
E101 FIRST FLOOR PLAN
E801 SCHEDULES