Cover Sheet.pdf

PDF 523 KB Posted

Attached to
751/24162. DPL; Yankee Springs Shooting Range
Solicitation number
RFQ-171-250000000319-3
Issued by
Baraga County, Michigan

About this file

This is a cover sheet and code compliance document for the Yankee Springs Shooting Range project, issued by the State of Michigan's Department of Technology, Management, and Budget (DTMB). The project is located at 10370 Gun Lake Road in Middleville, Michigan, and involves the construction of a new shooting range facility. The document is dated 04/08/2025 and includes a comprehensive code compliance diagram, building data summary, and project contact information. The facility is classified as a Use Group A-3, with a total square footage of 2,654 SF, one story, and a height of 19 feet.

The project will be designed and constructed in compliance with multiple Michigan and national building codes, including the Michigan Rehab Code, Michigan Building Code, International Fire Code, and various mechanical, plumbing, and electrical codes. Colliers Engineering and Design is serving as the architect and engineer for the project, with key personnel including David Moss, AIA, and Annia Alvarez-Nodarse, PE. The project requires obtaining all necessary permits and coordinating with local authorities, including a specific note to coordinate fire extinguisher locations with the fire marshal prior to installation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OCCUPANCY CLASSIFICATION':

• USE GROUP: A-3

SPRINKLED: NO

CONSTRUCTION TYPE: VB

BUILDING DATA: ACTUAL ALLOWABLE

• SQUARE FOOTAGE: 2654 SF 6000 SF

• HEIGHT: 19 FT 40'-0"

• NO. OF STORIES: 1 1

FIRE RATING (BUILDING ELEMENTS): REQUIRED PROVIDED

• STRUSTURAL FRAME: 0-HOUR 0-HOUR

• BEARING WALLS (EXTERIOR): 0-HOUR 0-HOUR

• BEARING WALLS (INTERIOR): 0-HOUR 0-HOUR

• NON BEARING WALLS (EXTERIOR): 0-HOUR 0-HOUR

• NON BEARING WALLS (INTERIOR): 0-HOUR 0-HOUR

• ROOF CONSTRUCTION: 0-HOUR 0-HOUR

MEANS OF EGRESS: REQUIRED PROVIDED

• MINIMUM NUMBER OF EXITS: 1 1

• EXIT ACCESS TRVAEL DISTANCE 200' PER PLANS

• DEAD-END LIMIT: 20' N/A

• COMMON PATH OF TRAVEL LIMIT: 30' N/A

• CORRIDOR FIRE RATING: 0-HOUR 0-HOUR

BUILDING DATA & CODE SUMMARY

1. APPLICABLE CODES:

A. CONSTRUCTION SHALL CONFORM TO THE FOLLOWING CODES:

• MICHIGAN REHAB CODE FOR EXISTING BUILDINGS, 2015 EDITION

• MICHIGAN BUILDING CODE, 2015 EDITION

• ICC A117.1, 2009 EDITION

• INTERNATIONAL FIRE CODE, 2012 EDITION

• MICHIGAN MECHANICAL CODE, 2021 EDITION

• MICHIGAN PLUMBING CODE, 2021 EDITION

• NATIONAL ELECTRIC CODE, 2023 EDITION

WORK SHALL CONFORM TO FEDERAL, STATE AND LOCAL CODES AS

NTERPRETED BY THE AUTHORITY HAVING JURISDICTION.

2. COMPLIANCE:

A. PROVIDE FIRE EXTINGUISHERS IN CONFORMANCE WITH THE FIRE CODE

SECTION 906 AND COORDINATE WITH FIRE MARSHAL PRIOR TO

INSTALLATION. DO NOT INSTALL FIRE EXTINGUISHERS UNTIL LOCATIONS

HAVE BEEN REVIEWED AND APPROVED BY THE AUTHORITY HAVING

JURISDICTION.

B. OBTAIN ALL REQUIRED PERMITS AND PAYMENT OF PERMIT AND APPLICATION

FEES FOR THE WORK.

GENERAL NOTES

TOILET ROOMS:

• ON SITE, LESS THAN 500' PER MPC 403.3.3

ENTRANCE

STORAGE

137 SF

STAGING

328 SF

7 PEOPLE

UNOCCUPIED

X75 1/2

.D

PL

YA

NK

EE

SP

RI

NG

S

SH

O O

TI

NG

RA

NG

E Y2

DA

TE

SH

EE

T

ID

EN

TI

FI

C

AT

IO

N

NO

IS

SU

ED

FO

R

G un La ke R oa d, M id dl ev ille ,M ic hi ga n

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y ,M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

LA

C

H ,R

A ,N

C A

R B

,D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

RV

IC

ES

A

D M

IN

IS

TR

A

TI

O

N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FI

LE

N O

P R

EL

IM

IN

A R Y

EN

GI

NE

ER

PR

OJ

EC

T

NO

IN

D

EX

N O

FI

N A L

R

EC

O R D

C O N S

TR

U C

TI

O N

DR

AW

N

DE

SI

GN

ED

AP

PR

OV

ED

C H

EC

KE

D

P.

A.

K

D.

P.

L.

R.

E.

G.

W es t S ag in aw

H w y.

S ui te

La ns in g, M I 4 of fic e:

.8

.8 w w w .c ol lie rs en gi ne er in g.

co m D.

P.

L.

R.

E.

G.

D.

P.

L.

R.

E.

G.

G000

1-

1-

PROJECT LOCATION MAP

PROJECT CONTACT LIST DRAWING INDEX

CED PROJECT: 24003879A

YANKEE SPRINGS

SHOOTING RANGE

10370 Gun Lake Road, Middleville, Michigan 49333

STATE OF MICHIGAN

DEPARTMENT OF TECHNOLOGY,

MANAGEMENT, AND BUDGET

ARCHITECT

COLLIERS ENGINEERING AND DESIGN

DAVID MOSS, AIA

7050 WEST SAGINAW HWY. SUITE 200

LANSING, MI 48917

517.827.8672

OWNER

STATE OF MICHIGAN,

DTMB

DAVID LENZ

430 W ALLEGAN ST.

LANSING, MI 48933

DATE: 04/08/2025

SITE

CIVIL ENGINEER

COLLIERS ENGINEERING AND DESIGN

ANNIA ALVAREZ-NODARSE, PE

7050 WEST SAGINAW HWY. SUITE 200

LANSING, MI 48917

517 827 8667

ELECTRICAL ENGINEER

COLLIERS ENGINEERING AND DESIGN

ANGIE ROBINSON, PE

7050 WEST SAGINAW HWY. SUITE 200

LANSING, MI 48917

517 827 3354

SCALE : 1/16" = 1'-0"1 CODE COMPLIANCE DIAGRAM - FIRST FLOOR N

DRAWING INDEX.

AD

D

EN

D

U M

/0

8/

00 - GENERAL

G000 COVER SHEET Yes

01 - CIVIL

X100 TOPOGRAPHIC MAPPING Yes C200 SITE PLAN Yes

C300 GRADING PLAN

C310 SESC PLAN

C311 SESC DETAILS

03 - STRUCTURAL

S001 GENERAL NOTES

04 - ARCHITECTURAL

A101 FIRST FLOOR PLAN

A103 FOUNDATION PLAN

A104 ROOF PLAN

A201 EXTERIOR ELEVATIONS

A301 BUILDING SECTIONS

A501 ENLARGED PLAN DETAILS

A521 SECTION DETAILS

A522 SECTION DETAILS

08 - ELECTRICAL

E001 LEGEND

ES001 SITE POWER PLAN

E101 FIRST FLOOR PLAN

E801 SCHEDULES

/0

8/

File details come from the government source that posted it. Updated .