C200 SITE PLAN.pdf

PDF 1 MB Posted

Attached to
751/24162. DPL; Yankee Springs Shooting Range
Solicitation number
RFQ-171-250000000319-3
Issued by
Baraga County, Michigan

About this file

This is a site plan document for a shooting range project by the State of Michigan Department of Technology, Management and Budget (DTMB), located in Yankee Springs near Middleville, Michigan. The site plan details the construction of a proposed shooting range approximately 2,663 square feet in size, with associated infrastructure including a gravel road, parking areas, underground electrical conduits, and site improvements. The plan includes specific design elements such as an 8-inch crushed limestone gravel section, concrete sidewalks, vault bathrooms, ADA striping, a 4-foot chain link fence with a 10-foot gate, and provisions for existing site features like trees and utilities.

The project involves careful site preparation and coordination, with specific instructions for contractors regarding utility verification, safety regulations, and environmental considerations. Key technical specifications include underground electrical conduit installation, directional drilling under the gravel road, vegetation removal with coordination with the DNR, and adherence to Michigan Department of Transportation standards. The site plan is part of the design and construction process, with detailed notes about permit requirements, utility adjustments, and contractor responsibilities for site restoration and as-built documentation. The project appears to be funded through the state's facilities and business services administration, with design by Colliers Engineering.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

G R

A V

E L R

O A

D

G U N

LA

K E R

O A D

G R

A V

E S

H

IL

L T

R A

IL

APPROXIMATE AREA FOR

PROPOSED GATE. COORDINATE

WITH TENANT FOR EXACT

LOCATION

EX. TREES

EX. TREES

EX. TREES

EX. GATE TO REMAIN

EX. WOOD POSTS

APPROXIMATE LOCATION OF

BURIED COMMUNICATIONS

EX. BACKSTOP AND BENCHES TO

BE SAVE ON SITE. COORDINATE

WITH TENANT FOR EXACT

STORAGE LOCATION

PROPOSED

SHOOTING

RANGE

±2663 SQ.

FT.

A

A

D

B

F

E

C

22.0'

18.0'

34.0'

22.0'

5.0'

5.0'

R60.0'

H

8.5'

(TYP.)

A

I

I

I

E X

O

V E R

H E A

D E

L E C

T R

IC

G

J

G1

GENERAL NOTES:

1. THE UNDERGROUND STRUCTURES AND UTILITIES SHOWN ON THESE PLANS HAVE BEEN PLOTTED

FROM AVAILABLE SURVEYS AND RECORD MAPS, THEY ARE NOT CERTIFIED TO THE ACCURACY OF

THEIR LOCATION AND/OR COMPLETENESS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE

LOCATION AND EXTENT OF ALL UNDERGROUND STRUCTURES AND UTILITIES PRIOR TO ANY

DIGGING OR CONSTRUCTION ACTIVITIES IN THEIR VICINITY.

2. THE CONTRACTOR SHALL PERFORM ALL WORK IN COMPLIANCE WITH TITLE 29 OF FEDERAL

REGULATIONS, PART 1926, SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION (OSHA).

3. ALL ROADS AND PRIVATE DRIVES SHALL BE KEPT CLEAN OF MUD, DEBRIS ETC. AT ALL TIMES.

4. REFER TO ARCHITECTURAL DRAWINGS FOR PRECISE BUILDING DIMENSIONS.

5. THE CONTRACTOR SHALL CONSULT THE CONSTRUCTION MANAGER BEFORE DEVIATING FROM

THESE PLANS.

6. IN ALL TRENCH EXCAVATIONS, CONTRACTOR MUST LAY THE TRENCH SIDE SLOPES BACK TO A SAFE

SLOPE, USE A TRENCH SHIELD OR PROVIDE SHEETING AND BRACING.

7. ALL EXISTING SURFACE APPURTENANCES (I.E. WATER VALVES, CATCH BASIN FRAMES AND GRATES, MANHOLE COVERS) WITHIN THE PROJECT LIMITS SHALL BE ADJUSTED TO FINISHED GRADE.

8. AREAS DISTURBED OR DAMAGED AS PART OF THIS PROJECT'S CONSTRUCTION THAT ARE OUTSIDE OF

THE PRIMARY WORK AREA SHALL BE RESTORED, AT THE CONTRACTOR'S EXPENSE, TO THE

SATISFACTION OF THE OWNER'S REPRESENTATIVE.

9. THE CONTRACTOR SHALL CALL "MISS DIG" AT LEAST 3 WORKING DAYS (EXCLUDING WEEKENDS AND

HOLIDAYS) PRIOR TO CONSTRUCTION.

10. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPLICABLE CODES, ORDINANCES, DESIGN STANDARDS AND STANDARD SPECIFICATIONS OF THE AGENCIES WHICH HAVE THE RESPONSIBILITY

OF REVIEWING PLANS AND SPECIFICATIONS FOR CONSTRUCTION OF ALL ITEMS INCLUDED IN THESE

PLANS.

11. UNLESS SPECIFICALLY STATED, THE CONTRACTOR SHALL APPLY FOR AND OBTAIN ALL NECESSARY

PERMITS AS REQUIRED FOR CONSTRUCTION OF THIS PROJECT PRIOR TO THE BEGINNING OF WORK

FROM THE PREVIOUSLY MENTIONED AGENCIES.

12. THE CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING THE SAFETY OF ALL PERSONS

AND PROPERTY. THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE

LIMITED TO NORMAL WORKING HOURS.

13. WHEN ANY EXISTING UTILITY REQUIRES ADJUSTMENT OR RELOCATION, THE CONTRACTOR SHALL

NOTIFY THE PROPER UTILITY COMPANY AND COORDINATE THE WORK ACCORDINGLY. THERE

SHALL BE NO CLAIM MADE BY THE CONTRACTOR FOR ANY COSTS CAUSED BY DELAYS IN

CONSTRUCTION DUE TO THE ADJUSTMENT OR RELOCATION OF UTILITIES.

14. THE CONTRACTOR IS TO VERIFY THAT THE PLANS AND SPECIFICATIONS THAT HE/SHE IS BUILDING

FROM ARE THE VERY LATEST PLANS AND SPECIFICATIONS THAT HAVE BEEN APPROVED BY ALL

APPLICABLE PERMIT-ISSUING AGENCIES AND THE OWNER. ALL ITEMS CONSTRUCTED BY THE

CONTRACTOR PRIOR TO RECEIVING THE FINAL APPROVAL AND PERMITS HAVING TO BE ADJUSTED

OR RE-DONE, SHALL BE DONE AT THE CONTRACTOR'S EXPENSE.

15. SHOULD THE CONTRACTOR ENCOUNTER CONFLICT BETWEEN THESE PLANS AND SPECIFICATIONS, EITHER AMONG THEMSELVES OR WITH THE REQUIREMENTS OF ANY AND ALL REVIEWING AND

PERMIT-ISSUING AGENCIES, HE/SHE SHALL SEEK CLARIFICATION IN WRITING FROM THE

CONSTRUCTION MANAGER BEFORE COMMENCEMENT OF CONSTRUCTION. FAILURE TO DO SO

SHALL BE AT THE SOLE EXPENSE TO THE CONTRACTOR.

16. THE CONTRACTOR SHALL FURNISH AS-BUILT DRAWINGS INDICATING ALL CHANGES AND

DEVIATIONS FROM APPROVED DRAWINGS.

17. ALL SIGNS AND TRAFFIC CONTROL MEASURES DURING CONSTRUCTION AND MAINTENANCE

ACTIVITIES SHALL BE CONSTRUCTED AND INSTALLED PER THE LATEST EDITION OF THE MICHIGAN

MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (M.M.U.T.C.D.).

18. ALL WORK WITHIN THE PUBLIC RIGHT OF WAY SHALL CONFORM TO THE STANDARDS OF THE

MICHIGAN DEPARTMENT OF TRANSPORTATION.

SITE LEGEND:

PROPOSED GRAVEL

NUMBER OF PARKING SPACES

EXISTING GRAVEL

KEY NOTEA

KEY NOTES:

A. GRAVEL SECTION - 8" 21AA CRUSHED LIMESTONE OVER 4" OF

NATURAL SAND COMPACTED AND PROOFROLLED AS

RECOMMENDED BY THE GEOTECH REPORT.

B. CONCRETE SIDEWALK 4" NON-REINFORCED CONCRETE OVER 4"

AGGREGATE BASE

C. CONCRETE PAVEMENT 6" NON-REINFORCED CONCRETE OVER 4"

AGGREGATE BASE

D. VAULT BATHROOMS (BY OTHERS)

E. ADA STRIPPING AND SIGNAGE

F. WHEEL STOP (TYP.)

G. PROPOSED UNDERGROUND ELECTRICAL CONDUIT TO PROVIDE

POWER FOR LIGHTING AND GENERAL PURPOSE OUTLETS.

CONDUIT TO BE CONNECTED TO THE EXISTING UTILITY POLE

EAST OF THE GRAVES HILL TRAIL. COORDINATE EXACT

LOCATION AND CONNECTION WITH TENANT AND ELECTRICAL

PLANS.

G1. APPROXIMATE 20' OF DIRECTIONAL DRILLING OF

UNDERGROUND ELECTRICAL CONDUITS UNDER THE GRAVEL

ROAD.

H. APPROXIMATE LOCATION OF PROPOSED TREE LINE.

I. REMOVE EXISTING VEGETATION AS NECESSARY TO

ACCOMMODATE PROPOSED GRAVEL DRIVE. IF NECESSARY

ADJUST GRAVEL DRIVE TO AVOID REMOVING LARGE TREES.

COORDINATE WITH DNR.

J. 4' TALL CHAIN LINK FENCE WITH 10' GATE

A

X75 1/2

.D

PL

YA

NK

EE

S

PR

IN

G S

SH

O

O

TI

NG

R

AN

G

E Y2

DA

TE

SH

EE

TI

DE

NT

IF

IC

AT

IO

N

NO

IS

SU

ED

F

OR

M id dl ev ille , M

I

D

EP

A R

TM

EN

T O

F

TE

C H

N O

LO

G

Y , M

A N

A G

EM

EN

T A

N D

B U

D G

ET

ST

A

TE

O

F M

IC

H

IG

A

N

A D

A M

L A

C H

, R A

, N C

A R

B , D

IR

EC

TO

R

FA

C

IL

IT

IE

S

A N

D B

U

SI

N

ES

S

SE

R V

IC

ES

A D

M

IN

IS

TR

A

TI

O N

D

ES

IG

N

A N

D C

O N

ST

R

U C

TI

O

N D

IV

IS

IO

N

FI

LE

N

O

P R

EL

IM

IN

A R Y

EN

GI

NE

ER

P

RO

JE

C T

NO

IN

D

EX

N O

FI

N A L R

EC

O R D

C O N S

TR

U C

TI

O N

DR

AW

N

DE

SI

GN

ED

AP

PR

OV

ED

C H

EC

KE

DK.

S.

W es t S ag in aw

H w y.

S ui te

La ns in g, M I 4 of fic e:

.8

.8 w w w .c ol lie rs en gi ne er in g.

co m

A.

A.

N.

A.

A.

N.

D.

M.

RELOCATED TREE LINE

PROPOSED CONCRETE

EXISTING TREE LINE

C200

SCALE : 1"=30'1 SITE PLAN

DEMO TREE LINE

EXISTING TREE LINE (TYP.)

H

R30.0'

R26.0'

R25.0'

R25.0'

R78.0'

1" = 30' SCALE BAR

30 60 90 FT

UNDERGROUND ELECTRIC SERVICE