Construction Documents _ McCLAVE DRIVE DRAINA.pdf
PDF 24 MB Posted
- Attached to
- MCCLAVE DRIVE DRAINAGE IMPROVEMENT
- Solicitation number
- PE-64452-NONST-2024-000000011
- Issued by
- Dekalb County, Georgia
About this file
The document provided is the Construction Documents for the McClave Drive Drainage Improvement project, a state and local contract opportunity issued by the City of Doraville in Georgia. The project involves drainage improvements to be performed in accordance with Georgia Department of Transportation's Standard Drawings, Standard Specifications, and Pay Items Index. The contractor must self-perform a minimum of 50% of the contract value. The work is for the Department of Public Works and is located in DeKalb County, Georgia.
The document does not provide any additional details on pricing terms, set asides, incumbents, funding requirements and sources, or other salient information beyond the project scope and location.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE LOCATION
SITE LOCATION
GENERAL NOTES
1. DEVELOPMENT SERVICES PERMITTING DISCLAIMER: THE APPROVAL OF THESE
PLANS AND THE ISSUANCE OF THIS LAND DISTURBANCE PERMIT DOES NOT IN ANY WAY
SUGGEST THAT ALL OTHER REQUIREMENTS FOR THE LEGAL OR APPROPRIATE
OPERATIONS FOR THIS ACTIVITY, WHICH MAY REQUIRE ADDITIONAL PERMITTING HAVE
BEEN MET. THE ONUS IS ON THE OWNER/DEVELOPER/BUILDER TO DISCOVER WHAT
ADDITIONAL PERMITTING OR APPROVALS MAY BE NECESSARY TO OPERATE FROM THIS
POINT IN AN APPROPRIATE AND LEGAL MANNER. PLAN APPROVAL OR PERMIT ISSUANCE
DOES NOT ABSOLVE THE APPLICANT FROM COMPLYING WITH ALL APPLICABLE LAWS,
STANDARDS, OR OTHER PERMITS WHICH MAY BE REQUIRED FOR THIS PROJECT.
2. ATTENTION IS DRAWN TO THE FACT THAT THE SCALE OF THESE DRAWINGS MAY HAVE
BEEN DISTORTED DURING THE REPRODUCTION PROCESS.
3. IF ANY CONFLICTS, DISCREPANCIES OR ANY OTHER UNSATISFACTORY CONDITIONS ARE
DISCOVERED, EITHER ON CONSTRUCTION DOCUMENTS OR FIELD CONDITIONS THE
CONTRACTOR MUST NOTIFY THE ENGINEER IMMEDIATELY AND SHALL NOT COMMENCE
FURTHER OPERATION UNTIL THE CONFLICTS, DISCREPANCIES, OR OTHER
UNSATISFACTORY CONDITIONS ARE RESOLVED
4. PRIOR TO LAND DISTURBING AND/OR CONSTRUCTION ACTIVITIES, THE CONTRACTOR
SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE AREA EROSION CONTROL /
SITE DEVELOPMENT INSPECTOR.
5. THE EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN PREPARED FROM THE
INFORMATION AVAILABLE TO THE ENGINEER AND MAY NOT BE ACCURATE TO EXTENT OR
LOCATIONS, PRIOR TO BEGINNING ANY WORK, THE CONTRACTOR SHALL NOTIFY UTILITIES
AND THEN MARK OR REMARK THEIR FACILITIES.
6. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL EXISTING VEGETATION WHICH
DOES NOT UNREASONABLY INTERFERE WITH CONSTRUCTION.
7. THE CONTRACTOR SHALL CAREFULLY PRESERVE BENCH MARKS, REFERENCE POINTS AND
STAKES.
8. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND LICENSES FOR EXECUTION
OF ALL MATERIALS. THE EXECUTION OF THE WORK SHALL BE IN ACCORDANCE WITH THE
STATE AND LOCAL CODES, RULES, AND REGULATIONS.
9. TESTING SHALL BE DONE BY THE CONTRACTOR UNLESS OTHERWISE NOTED.
10. SHORING SHALL BE DONE AS NECESSARY FOR THE PROTECTION OF THE WORK AND FOR
THE SAFETY OF PERSONNEL.
11. SHORING SHALL BE IN ACCORDANCE WITH SECTION 7 OF THE MANUAL OF ACCIDENT
PROTECTION IN CONSTRUCTION AS PUBLISHED BY THE ASSOCIATED GENERAL
CONTRACTORS OF AMERICA, OSHA, AND THE LOCAL REGULATIONS
DEVELOPMENT TEAM
OWNER
CITY OF DORAVILLE
3725 PARK AVENUE
DORAVILLE, GA 30340
PHONE: 470-223-4222
EMAIL:
CHRIS.LAFLEUR@DORAVILLEGA.US
CONTACT: CHRIS LAFLEUR
CIVIL ENGINEER
LOWE ENGINEERS
990 HAMMOND DRIVE
SUITE 900
ATLANTA, GA 30328
PHONE: 770-857-8428
EMAIL:
HELEN.SIMPSON@LOWEENGINEERS.COM
CONTACT: HELEN SIMPSON, PE
SURVEYOR
TERRAMARK
1396 BELLS FERRY ROAD
MARIETTA, GA 30066
PHONE:770-421-1927
CONTACT: JOHN BLOUNT
GOVERNING AGENCIES
STORMWATER
CITY OF DORAVILLE
3725 PARK AVENUE,
DORAVILLE, GA 30340
PHONE: 770-451-8745
SHEET LIST TABLE
Sheet Number Sheet Title
C0.00 COVER
C1.00 GENERAL NOTES
C2.00 DEMOLITION PLAN
C3.00 DRAINAGE PLAN
C3.10 STORM PROFILE AND DETAILS
C3.20 STORM CALCULATION
C4.10 EROSION CONTROL PLAN
C4.20 EROSION CONTROL DETAILS
C4.21 EROSION CONTROL DETAILS
C5.00 CONSTRUCTION DETAILS
C5.01 CONSTRUCTION DETAILS
C5.02 CONSTRUCTION DETAILS
C5.03 CONSTRUCTION DETAILS
C5.04 CONSTRUCTION & MUTCD STANDARD LANE
CLOSURE DETAIL
PROJECT NARRATIVE
THE PROPOSED STORM SEWER IMPROVEMENTS ARE DESIGNED TO IMPROVE THE DRAINAGE
ON McCLAVE DRIVE NEAR AUTUMN DRIVE. THESE IMPROVEMENTS WILL REDUCE ROADWAY
FLOODING AND RELIEVE FLOODING IMPACTS TO THE RESIDENTIAL PROPERTIES LOCATED TO
THE SOUTH OF McCLAVE DRIVE WITHIN THIS PROJECT SCOPE LIMITS
CONSTRUCTION DOCUMENTS FOR
McCLAVE DRIVE DRAINAGE IMPROVEMENTS McCLAVE DRIVE
DORAVILLE, GA 30340
PREPARED FOR:
CITY OF DORAVILLE
3725 PARK AVENUE, DORAVILLE, GA 30340
SITE LOCATION MAP
NOT TO SCALE
FEMA FIRM MAP
FEMA FIRM PANEL NO.: 13089C0019K
DATED: 8/15/2019
NOT TO SCALE
PREPARED BY:
990 HAMMOND DRIVE, SUITE 900
ATLANTA, GEORGIA 30328
(770) 857-8400
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \S
H
EE
TS
\C
0.
C O
VE
R.
dw g
L
AS
T
SA
VE
D
BY
: J
KW
O
N
2/ 4/
A
T 5:
P
M
PL
O
TT
ED
B
Y:
JK
W O
N
2/ 4/
A
T 5:
P
M
PA
PE
R
SI
ZE
: A
RC
H F
U
LL
B
LE
ED
D
(3 6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G T
O P
DF
.P
C3
PL
O T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
C0.00
CO
VE
R M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D
O
RA
VI
LL
E, G
A
JK
HLS
23-250006
ZO
N
IN
G
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
12/04/2023
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
N/A
LA
N
D
LO
T
DI
ST
RI
CT
PA
RC
EL
ID
HELEN SIMPSON, PE
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \S
H
EE
TS
\C
0.
G
EN
ER
AL
N O
TE
S.
dw g
L
AS
T
SA
VE
D
BY
: J
KW
O
N
1/
/2
A T
:0
AM
PL
O
TT
ED
B Y:
JK
W
O N
2/
4/
A T
5:
P M
PA
PE
R
SI
ZE
: A
RC
H
F U
LL
B
LE
ED
D (3
6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G
T O
P
DF
.P C3
PL
O
T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
LOWE ENGINEERS NOTES
GENERAL NOTES
A. DEVELOPMENT SERVICES PERMITTING DISCLAIMER: THE APPROVAL OF THESE PLANS AND THE ISSUANCE OF THIS
LAND DISTURBANCE PERMIT DOES NOT IN ANY WAY SUGGEST THAT ALL OTHER REQUIREMENTS FOR THE LEGAL OR APPROPRIATE OPERATIONS FOR THIS ACTIVITY, WHICH MAY REQUIRE ADDITIONAL PERMITTING HAVE BEEN MET.
THE ONUS IS ON THE OWNER/DEVELOPER/BUILDER TO DISCOVER WHAT ADDITIONAL PERMITTING OR APPROVALS MAY BE NECESSARY TO OPERATE FROM THIS POINT IN AN APPROPRIATE AND LEGAL MANNER. PLAN APPROVAL OR PERMIT ISSUANCE DOES NOT ABSOLVE THE APPLICANT FROM COMPLYING WITH ALL APPLICABLE LAWS, STANDARDS, OR OTHER PERMITS WHICH MAY BE REQUIRED FOR THIS PROJECT.
B. ATTENTION IS DRAWN TO THE FACT THAT THE SCALE OF THESE DRAWINGS MAY HAVE BEEN DISTORTED DURING
THE REPRODUCTION PROCESS.
C. IF ANY CONFLICTS, DISCREPANCIES OR ANY OTHER UNSATISFACTORY CONDITIONS ARE DISCOVERED, EITHER ON CONSTRUCTION DOCUMENTS OR FIELD CONDITIONS THE CONTRACTOR MUST NOTIFY THE ENGINEER IMMEDIATELY AND SHALL NOT COMMENCE FURTHER OPERATION UNTIL THE CONFLICTS, DISCREPANCIES, OR
OTHER UNSATISFACTORY CONDITIONS ARE RESOLVED
D. PRIOR TO LAND DISTURBING AND/OR CONSTRUCTION ACTIVITIES, THE CONTRACTOR SHALL SCHEDULE A PRE-CONSTRUCTION MEETING WITH THE AREA EROSION CONTROL / SITE DEVELOPMENT INSPECTOR.
E. THE EXISTING UTILITIES SHOWN ON THE PLANS HAVE BEEN PREPARED FROM THE INFORMATION AVAILABLE TO THE ENGINEER AND MAY NOT BE ACCURATE TO EXTENT OR LOCATIONS, PRIOR TO BEGINNING ANY WORK, THE
CONTRACTOR SHALL NOTIFY UTILITIES AND THEN MARK OR REMARK THEIR FACILITIES.
F. THE CONTRACTOR SHALL PRESERVE AND PROTECT ALL EXISTING VEGETATION WHICH DOES NOT UNREASONABLY
INTERFERE WITH CONSTRUCTION.
G. THE CONTRACTOR SHALL CAREFULLY PRESERVE BENCH MARKS, REFERENCE POINTS AND STAKES.
H. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND LICENSES FOR EXECUTION OF ALL MATERIALS. THE EXECUTION OF THE WORK SHALL BE IN ACCORDANCE WITH THE STATE AND LOCAL CODES, RULES, AND
REGULATIONS.
I. TESTING SHALL BE DONE BY THE CONTRACTOR UNLESS OTHERWISE NOTED.
J. SHORING SHALL BE DONE AS NECESSARY FOR THE PROTECTION OF THE WORK AND FOR THE SAFETY OF
PERSONNEL.
K. SHORING SHALL BE IN ACCORDANCE WITH SECTION 7 OF THE MANUAL OF ACCIDENT PROTECTION IN CONSTRUCTION AS PUBLISHED BY THE ASSOCIATED GENERAL CONTRACTORS OF AMERICA, OSHA, AND THE LOCAL
REGULATIONS
L. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL STATE, CITY AND COUNTY REGULATIONS AND CODES AND
O.S.H.A. STANDARDS.
M. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR PRECISE BUILDING DIMENSIONS, BUILDING UTILITY ENTRANCE LOCATIONS, EXACT LOCATIONS AND DIMENSIONS OF ENTRIES, SIDEWALKS, DOWNSPOUTS, AND
BOLLARDS IN BUILDING SIDEWALKS.
N. UNLESS SHOWN OTHERWISE ON THE PLANS, CONTRACTOR SHALL APPLY 6" OF TOP SOIL TO ALL DISTURBED AREAS OF THE SITE, PLANT GRASS SEED OR SOD, APPLY STRAW, AND WATER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ESTABLISH A HEALTHY STAND OF GRASS ON ALL SEEDED OR SODDED AREAS. IF A HEALTHY STAND OF GRASS CAN NOT BE ESTABLISHED BY THE TIME THE BUILDING BECOMES OCCUPIED, THEN SOD SHALL BE
INSTALLED AND WATERED UNTIL GRASS IS ESTABLISHED.
O. ALL ISLANDS WITH CURB & GUTTER SHALL BE LANDSCAPED. THOSE ISLANDS ARE TO HAVE CURB & GUTTER AS
SHOWN IN THESE PLANS AND THE CONSTRUCTION DRAWINGS.
P. ALL DIMENSIONS AND RADII ARE REFERENCED TO THE FACE OF CURB UNLESS OTHERWISE NOTED. ALL BUILDING DIMENSIONS ARE REFERENCED TO THE OUTSIDE FACE OF THE STRUCTURE UNLESS OTHERWISE NOTED.
Q. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RELOCATIONS, INCLUDING BUT NOT LIMITED TO, ALL UTILITIES, STORM DRAINAGE, SIGNS, ETC. AS REQUIRED. ALL WORK SHALL BE IN ACCORDANCE WITH GOVERNING AUTHORITIES SPECIFICATIONS AND SHALL BE APPROVED BY SUCH. ALL COST SHALL BE INCLUDED IN BID. AREAS TO BE DISTURBED SHALL BE IMPROVED PER THESE PLANS OR RESTORED TO THEIR ORIGINAL OR BETTER CONDITION.
R. ACCESSIBLE SIGNS WITH A "VAN" MARKING SHALL HAVE ADDITIONAL SIGN MOUNTED BELOW THE SYMBOL OF ACCESSIBILITY SIGN DENOTING VAN ACCESSIBILITY. ALL ACCESSIBLE SIGNS SHALL MEET THE CURRENT MINIMUM
ADA AND LOCAL STANDARDS.
S. ALL HEIGHTS AND SETBACKS SHALL MEET THE MINIMUM STANDARDS SET FORTH IN THE LOCAL CODE.
T. THE CONTRACTOR SHALL EMPLOY ALL NECESSARY BARRICADES, SIGNS, FENCES, FLASHING LIGHTS, TRAFFIC MEN, ETC. FOR MAINTENANCE AND PROTECTION OF TRAFFIC AS REQUIRED.
U. THE CONTRACTOR SHALL PROTECT ALL MONUMENTS, IRON PINS, AND PROPERTY CORNERS DURING
CONSTRUCTION.
V. CONTRACTOR AGREES TO REPAIR ANY DAMAGE TO THE PUBLIC RIGHT-OF-WAY IN ACCORDANCE WITH THE
STANDARDS OF THE DEPARTMENT OF TRANSPORTATION.
W. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO THE OWNER ANY DISCREPANCIES FOUND BETWEEN THE ACTUAL FIELD CONDITIONS AND THE CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO
PROCEEDING
DEMOLITION
A. THE CONTRACTOR SHALL FIELD VERIFY AND LOCATE ALL EXISTING UTILITIES ON SITE PRIOR TO ANY DEMOLITION OR
CONSTUCTION ACTIVITY.
B. THE CONTRACTOR SHALL PERFORM DEMOLITION ACTIVITIES AS NOTED AND SHOWN ON THESE PLANS.
C. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN ANY PERMITS AND PAY FEES REQUIRED FOR
D. DEMOLITION AND HAUL-OFF FROM THE APPROPRIATE AUTHORITIES.
E. THE CONTRACTOR SHALL PREPARE ALL DOCUMENTS AND ACQUIRE APPROPRIATE PERMITS AS REQUIRED
F. PRIOR TO THE COMMENCEMENT OF DEMOLITION.
G. THE DEMOLITION PLAN IS INTENDED TO DEPICT GENERAL DEMOLITION AND UTILITY WORK. IT IS NOT INTENDED TO IDENTIFY EACH ELEMENT OF DEMOLITION OR RELOCATION. CONTRACTOR SHALL COORDINATE WITH THE
OWNER AND APPROPRIATE UTILITY COMPANY PRIOR TO ANY CONSTRUCTION ACTIVITY.
H. IN ACCORDANCE WITH THE DEMOLITION PLAN, CONTRACTOR TO COMPLETELY DEMOLISH AND DISPOSE OF ANY MATERIALS OFFSITE IN A LAWFUL MANNER EXISTING BUILDINGS, INCLUDING BUT NOT LIMITED TO FOUNDATIONS AND ALL APPURTENANCES (I.E. BOLLARDS, GAS METERS, AIR CONDITIONING UNITS, SIGNS, CURBS, SIDEWALKS, ELECTRIC METERS, FENCING, ETC.)
I. REMOVE AND/OR PLUG EXISTING UTILITIES SUCH AS SANITARY SEWER, WATER, GAS, ELECTRIC, AND TELEPHONE AS SHOWN. THE CONTRACTOR IS RESPONSIBLE FOR CONTACTING EACH UTILITY COMPANY TO COORDINATE REMOVAL OF ALL UTILITIES AND FOR DETERMINING HORIZONTAL AND VERTICAL LOCATIONS OF UTILITIES PRIOR TO
COMMENCING WORK.
J. THE CONTRACTOR SHALL CUT AND PLUG, OR ARRANGE FOR THE APPROPRIATE UTILITY COMPANY TO CUT AND PLUG, ALL SERVICE PIPING AT THE STREET LINE OR MAIN, AS REQUIRED, OR AS OTHERWISE NOTED. ALL SERVICES MAY NOT BE SHOWN ON THIS PLAN. THE CONTRACTOR SHALL INVESTIGATE THE SITE PRIOR TO BIDDING TO
DETERMINE THE EXTEND OF SERVICE PIPING TO BE REMOVED, CUT OR PLUGGED.
K. THE CONTRACTOR SHALL ARRANGE FOR RESETTING OF CURB BOXES, VALVE BOXES AND REMOVAL AND/OR
RELOCATION OF OVERHEAD UTILITIES AND POLES WITH THE APPROPRIATE UTILITY COMPANY.
L. INSTALL ALL EROSION AND SEDIMENT CONTROL DEVICES AND TREE PROTECTION PRIOR TO BEGINNING
DEMOLITION WORK.
M. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL UTILITIES TO REMAIN IN PLACE.
N. THE CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO AVOID UNNECESSARY DAMAGE TO EXISTING ROAD SURFACE.
O. SAWCUT AT INTERFACE OF PAVEMENT OR CURB TO REMAIN. SAWCUT EXISTING PAVEMENT AT THE R/W.
P. ALL EXISTING ITEMS TO REMAIN WHICH ARE DAMAGED DURING CONSTRUCTION SHALL BE RESTORED TO ITS
ORIGINAL CONDITION AT THE SOLE EXPENSE OF THE CONTRACTOR.
Q. THE CONTRACTOR SHALL MAINTAIN ALL UTILITY SERVICES TO THE ADJOINING PROPERTIES DURING THE
DEMOLITION PROCESS.
R. SHOULD ANY UNCHARTED OR INCORRECTLY CHARTED EXISTING PIPING OR OTHER UTILITY BE UNCOVERED DURING EXCAVATION, CONSULT THE ENGINEER IMMEDIATELY FOR DIRECTION BEFORE PROCEEDING FURTHER WITH WORK
IN THIS AREA.
S. ASBESTOS OR HAZARDOUS MATERIAL, IF FOUND ON SITE, SHALL BE REMOVED BY A LICENSED HAZARDOUS
MATERIAL CONTRACTOR AND DISPOSED OF PROPERLY
GRADING
A. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS
SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS
SHOWN ON THE PLANS.
B. ALL CUT OR FILL SLOPES SHALL BE 2:1 OR FLATTER UNLESS OTHERWISE NOTED.
C. EXISTING AND PROPOSED GRADE CONTOUR INTERVALS SHOWN IN SURVEY.
D. CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO ASSURE A SMOOTH FIT AND
CONTINUOUS GRADE.
E. CONTRACTOR SHALL ASSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL NATURAL AND PAVED AREAS.
F. TOPOGRAPHIC INFORMATION TAKEN FROM A TOPOGRAPHIC SURVEY BY -------, DATED ---------.
G. ALL UNSURFACED AREAS DISTURBED BY GRADING OPERATION SHALL RECEIVE 6 INCHES OF TOPSOIL.
H. CONTRACTOR SHALL APPLY STABILIZATION FABRIC TO ALL SLOPES 3H:1V OR STEEPER. CONTRACTOR SHALL GRASS
AND MAINTAIN DISTURBED AREAS UNTIL A HEALTHY STAND OF GRASS IS OBTAINED.
I. CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE GOVERNING CODES AND BE CONSTRUCTED TO SAME.
J. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL STATE AND LOCAL REGULATIONS AND CODES AND OSHA
STANDARDS.
K. ALL PROPOSED CONTOURS AND SPOT ELEVATIONS REFLECT FINISHED GRADES.
L. ALL ELEVATIONS ARE IN REFERENCE TO THE BENCHMARK, AND THIS MUST BE VERIFIED BY THE GENERAL
CONTRACTOR PRIOR TO GROUND BREAKING.
M. THE CONTRACTOR SHALL IMMEDIATELY REPORT TO OWNER ANY DISCREPANCIES FOUND BETWEEN ACTUAL FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS AND SHALL WAIT FOR INSTRUCTION PRIOR TO PROCEEDING.
N. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING EXISTING UTILITIES, AND SHALL REPAIR
ALL DAMAGE TO EXISTING UTILITIES THAT OCCUR DURING CONSTRUCTION.
O. CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY TO TRANSITION BACK TO EXISTING GRADE.
P. ALL SITE PREPARATION AND UNSUITABLE SOIL REMOVAL, AS WELL AS THE PLACEMENT OF FILL MATERIALS SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL REPORT (BY OTHERS).
Q. LIMITS OF CLEARING SHOWN ON GRADING PLAN ARE BASED UPON THE APPROXIMATE CUT AND FILL SLOPE LIMITS, OR OTHER GRADING REQUIREMENTS.
R. THE PROPOSED CONTOURS SHOWN IN DRIVES AND PARKING LOTS AND SIDEWALKS ARE FINISHED ELEVATIONS INCLUDING PAVEMENT. REFER TO PAVEMENT CROSS SECTION DATA TO ESTABLISH CORRECT SUBBASE OR
AGGREGATE BASE COURSE ELEVATIONS.
S. CONTRACTOR SHALL INSURE POSITIVE DRAINAGE SO THAT RUNOFF WILL DRAIN BY GRAVITY FLOW ACROSS NEW
PAVEMENT AREAS TO NEW OR EXISTING DRAINAGE INLETS OR SHEET OVERLAND.
T. ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION AS SHOWN ON THE GRADING PLAN IS PROHIBITED.
U. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, BRACING AND SPECIAL EXCAVATION MEASURES REQUIRED TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS PURSUANT TO THE INSTALLATION OF THE WORK INDICATED ON THESE DRAWINGS. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE DESIGN(S) TO INSTALL SAID ITEMS. THE CONTRACTOR SHALL INCLUDE IN THE BID ANY DEWATERING AND MOISTURE CONDITIONING NECESSARY TO CONSTRUCT THE PROJECT AS SHOWN ON
THE PLANS.
V. ALL FOUNDATION EXCAVATION SHALL BE INSPECTED BY A QUALIFIED GEOTECHNIAL REPRESENTATIVE TO DETERMINE WHETHER UNSUITABLE MATERIAL MUST BE REMOVED. ALL UNDESIRABLE MATTER SHALL BE REMOVED, BACKFILLED AND COMPACTED AS REQUIRED BY THE GEOTECHNICAL REPRESENTATIVE.
W. GRADES, ELEVATIONS AND LOCATIONS SHOWN ARE APPROXIMATE. AS DIRECTED BY THE ENGINEER, THEY MAY BE ADJUSTED TO ACCOMMODATE UNFORESEEN CONDITIONS. STATIONS, OFFSETS AND ELEVATIONS REFER TO THE CENTER OF DROP INLETS, MANHOLES AND JUNCTION BOXES, AND THE MIDPOINT OF THE GUTTERS AND EDGE OF
PAVEMENT FOR CATCH BASINS.
DRAINAGE
A. CONTRACTOR TO CONFIRM STRUCTURE ELEVATIONS SHOWN AND PROVIDE SHOP DRAWINGS TO OWNER &
ENGINEER FOR REVIEW PRIOR TO ORDERING OF OR INSTALLATION OF STRUCTURES. PRECAST STRUCTURES MAY BE
USED AT CONTRACTORS OPTION.
B. STORM PIPE SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED:
TYPE 1: RCP, CLASS III PER ASTM C-76, WITH FLEXIBLE PLASTIC BITUMEN GASKETS AT JOINTS.
TYPE 2: SPIRAL RIB METAL PIPE TYPE 1R: ALUMINIZED COATED AS SPECIFIED ON CONSTRUCTION
DRAWINGS. ONLY PERMITTED WHEN SPECIFICALLY INDICATED ON CONSTRUCTION
DRAWINGS. PIPE ENDS SHALL BE RE-CORRUGATED AND INSTALLED WITH
SEMI-CORRUGATED HUGGER-TYPE BANDS AND "O" RING GASKETS IN ACCORDANCE WITH
PIPE MANUFACTURER'S INSTALLATION REQUIREMENTS.SPIRAL RIB METAL PIPE MUST
COMPLY WITH ASTM A 760 TYPE 1R. ACCEPTABLE MANUFACTURER: CONTECH, INC." ULTRA
FLO OR ULTRA FLO II", CALDWELL CULVERT CO. "SMOOTH RIB", OR APPROVED EQUAL.
TYPE 3: HIGH DENSITY POLYETHYLENE, ADS N-12 ST IB PIPE (PER AASHTO M294), OR APPROVED
EQUAL, SHALL HAVE A SMOOTH INTERIOR AND ANNULAR EXTERIOR CORRUGATIONS. 4-
THROUGH 60-INCH SHALL MEET AASHTO M294. PIPE SHALL BE JOINED USING A BELL &
SPIGOT JOINT MEETING AASHTO M294. THE JOINT SHALL BE SOIL-TIGHT AND GASKETS,
WHEN APPLICABLE, SHALL MEET THE REQUIREMENTS OF ASTM F477. FITTINGS SHALL
CONFORM TO ASTM F 2306. MATERIAL FOR PIPE PRODUCTION SHALL BE AN ENGINEERED
COMPOUND OF VIRGIN AND RECYCLED HIGH DENSITY POLYETHYLENE CONFORMING WITH THE
MINIMUM REQUIREMENTS OF CELL CLASSIFICATION 424420C (ESCR TEST CONDITION B)
FOR 4- THROUGH 10-INCH (100 TO 250 MM) DIAMETERS, AND 435420C (ESCR TEST CONDITION
B) FOR 12- THROUGH 60-INCH DIAMETERS, AS DEFINED AND DESCRIBED IN THE LATEST
VERSION OF ASTM D3350, EXCEPT THAT CARBON BLACK CONTENT SHOULD NOT EXCEED
4%. INSTALLATION SHALL BE IN ACCORDANCE WITH ASTM D2321 OR PER MANUFACTURER'S
RECOMMENDATION.
C. EXISTING DRAINAGE STRUCTURES TO BE INSPECTED AND REPAIRED AS NEEDED, AND EXISTING PIPES TO BE
CLEANED OUT TO REMOVE ALL SILT AND DEBRIS.
D. IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING
CONDITIONS OR BETTER.
E. ALL STORM PIPE ENTERING STRUCTURES SHALL BE GROUTED TO ASSURE CONNECTION AT STRUCTURE IS
WATERTIGHT.
F. ALL STORM SEWER MANHOLES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT, AND SHALL HAVE TRAFFIC BEARING RING & COVERS. MANHOLES IN UNPAVED AREAS SHALL BE 6" ABOVE FINISH GRADE. LIDS SHALL BE
LABELED "STORM SEWER".
G. ALL STORM STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR INVERT FROM INVERT IN TO INVERT
OUT.
H. ALL STORM DRAINAGE WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE CLASS III REINFORCED CONCRETE PIPE, UNLESS
OTHERWISE SHOWN.
I. ALL PIPE LENGTHS AND SLOPES ARE APPROXIMATE.
J. ALL PIPES SHALL BE LAID ON STRAIGHT ALIGNMENTS AND EVEN GRADES USING A PIPE LASER OR OTHER ACCURATE
METHOD.
K. SUBSURFACE DRAINAGE FACILITIES MAY RE REQUIRED IN THE STREET RIGHT-OF-WAY IF DEEMED NECESSARY BY
THE INSPECTOR.
L. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN
ADDITION TO OTHER APPLICABLE CRITERIA:
NO MORE THAN 500 LF OF TRENCH MAY BE OPENED AT ONE TIME.
EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES.
EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN
APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT
DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF-SITE PROPERTY.
MATERIAL USED FOR BACK-FILLING TRENCHES SHALL BE PROPERLY COMPACTED IN ORDER
TO MINIMIZE EROSION AND PROMOTE STABILIZATION.
DESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THE EROSION AND
SEDIMENTCONTROL REGULATIONS.
APPLICABLE SAFETY REGULATIONS SHALL BE COMPLIED WITH.
M. THIS PLAN DETAILS PIPES UP TO 5FT FROM THE BUILDING FACE. REFER TO ARCHITECTURAL DRAWINGS FOR BUILDING CONNECTIONS. CONTRACTOR SHALL SUPPLY AND INSTALL PIPE ADAPTERS AS NECESSARY.
N. STRUCTURE TOP ELEVATIONS SHOWN HERE ARE APPROXIMATE. CONTRACTOR SHALL ADJUST AS NECESSARY.
UTILITY
A. ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES.
B. CONTRACTOR SHALL NOTIFY THE UTILITY AUTHORITIES INSPECTORS 72-HOURS BEFORE CONNECTING TO ANY
EXISTING LINE.
C. SANITARY SEWER PIPE, SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED ON PLANS:
PVC PER ASTM D 3034
DUCTILE IRON PIPE PER AWWA C150
PIPE RUNS BETWEEN MANHOLES TO BE THE SAME CLASS.
D. WATER LINES, SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED ON PLANS:
PVC C-900 PER ASTM D 2241, CLASS 200 UNDER PUBLIC ROADS, OTHERWISE CLASS 150
DUCTILE IRON PIPE PER AWWA C150
EITHER COPPER TUBE TYPE "L" (SOFT) PER ANSI 816.22
PVC, 200 P.S.I. PER ASTM D1784 AND D2241.
E. MINIMUM TRENCH WIDTH SHALL BE IN ACCORDANCE WITH LOCAL GOVERNING CODES AS SHOWN IN THE
CONSTRUCTION DETAILS IN THESE PLANS.
F. ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH THRUST BLOCKING AS CALLED OUT IN THE
SPECIFICATIONS IN THE DETAILS.
G. ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE
(OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE).
H. CONTRACTOR SHALL MAINTAIN A MINIMUM OF 4'-0" COVER ON ALL WATERLINES.
I. UNLESS OTHERWISE NOTED BY LOCAL JURISDICTIONS: IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATERLINES, SANITARY LINES, STORM LINES AND GAS LINES (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE DUCTILE IRON PIPE WITH MECHANICAL JOINTS AT LEAST 10 FEET ON BOTH SIDES OF CROSSING, THE WATERLINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE THRUST BLOCKING AS REQUIRED TO PROVIDE A MINIMUM OF 18" CLEARANCE. MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA C-151) (CLASS 50).
J. LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING.
K. TOPS OF EXISTING MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH PROPOSED PAVEMENT ELEVATIONS, AND TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATIONS IN UNPAVED AREAS WITH WATER
TIGHT LIDS.
L. ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION STRENGTH AT 3,000 P.S.I.
UNLESS OTHERWISE NOTED BY LOCAL JURISDICTIONS.
M. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES.
N. REFER TO INTERIOR PLUMBING DRAWINGS (BY OTHERS) FOR TIE-IN OF ALL UTILITIES.
O. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE LOCAL JURISDICTION WITH
REGARDS TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES.
P. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS WAS PROVIDED BY THE LAND SURVEYOR AND IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH
THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
Q. THE CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND
SPECIFICATIONS PRIOR TO ANY CONSTRUCTION ACTIVITY.
R. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT
WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS.
S. ALL EXISTING AND PROPOSED UTILITY MAIN LENGTHS SHOWN ARE APPROXIMATE.
T. ALL EXISTING UTILITIES PROPOSED TO BE RELOCATED ON THESE PLANS SHALL BE PLACED UNDERGROUND, UNLESS
OTHERWISE NOTED
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
C1.00
G
EN
ER
AL
N O
TE
S
M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D O
RA
VI
LL
E, G A
JK
HLS
23-250006
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
12/04/2023
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
EXISTING PROPERTY LINE
EXISTING RIGHT-OF-WAY
EXISTING SETBACK LINE
PROPOSED RIGHT-OF-WAY
PROPOSED SETBACK LINE
100 YEAR FLOOD PLAIN
PROPOSED RETAINING WALL
CROSS WALK
YIELD
ONLY
T
J
EXISTING MINOR CONTOURS123
EXISTING MAJOR CONTOURS123
PROPOSED MINOR CONTOURS123
123 PROPOSED MAJOR CONTOURS
EXISTING STORM LINE
PROPOSED STORM LINE
PROPOSED SPOT ELEVATION123.45
2% PROPOSED SLOPE ARROW
PROPOSED TOP OF FINISHED GRADETFG:123.45
EXISTING SPOT ELEVATION123.45
EXISTING TOP OF FINISHED GRADETFG:123.45
EXISTING BOTTOM OF FINISHED GRADEBFG:123.45
PROPOSED BOTTOM OF FINISHED GRADEBFG:123.45
LOD LIMITS OF DISTURBANCE
HEAVY DUTY PAVING
STANDARD DUTY PAVING
CONCRETE
SANITARY SEWER MANHOLE
HEADWALL
OUTLET CONTROL STRUCTURE
YARD INLET
SINGLE WING CATCH BASIN
DOUBLE WING CATCH BASIN
STORM MANHOLE
GRATE INLET
TRANSFORMER PAD
DUMPSTER PAD
LIGHT POLE
SIGN
PARKING COUNT
ADA STANDARD CURB RAMP
CONCRETE WHEEL STOP
HANDICAP STALL SYMBOL
"ONLY" DIRECTIONAL ARROWS (PAVEMENT MARKINGS)
DIRECTIONAL ARROWS - PAVEMENT MARKINGS
YIELD - PAVEMENT MARKINGS
TRAFFIC FLOW ARROW - PAVEMENT MARKINGS
STOP BAR - PAVEMENT MARKINGS
OHP ELEC. OVERHEAD LINE
UGP ELEC. UNDERGROUND LINE
G GAS LINE
SAN SEWER LINE
FM SEWER FORCEMAIN
OHT TELE. OVERHEAD LINE
UGT
W WATER LINE
TELE. UNDERGROUND LINE
SANITARY SEWER MANHOLE
SANITARY SEWER CLEANOUT
POST INDICATOR VALVE
WATER METER
WATER BENDS 11.25° - 90°
WATER TEE WITH THRUST BLOCK
GATE VALVE
DOUBLE DETECTOR CHECK VALVE ASSEMBLY
FOC FIBER OPTIC LINE
FIRE HYDRANT
FIRE DEPARTMENT CONNECTION
GREASE TRAP
POWER POLE
S
S S
W
DDC
FDC
DRAWING LEGEND
ZO
N
IN
G
LA
N
D
LO
T
DI
ST
RI
CT
PA
RC
EL
ID
HELEN SIMPSON, PE
N/A
93793
9 93
W W
W
W W
W W
W W
W W
W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W
W W
W W
W W
W W
W W
W
G
SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN
X
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FO
C
FO
C
FO
C
FOC
FOC
FOC
FOC
FOC
FOC
FOC
FOC
17"POP
24"
9"POP
3"DOG
21"POP
19"POP
20"
20" 20"MAP
29"POP
18"
18"
10"
14"POP
9"HW
36"POP
12"POP
6"DOG
8"HW
19"
26"HW
15"
3"ORN
15"POP
5"DOG
15"
38"POP
9"OAK
13"
18"POP
17"
17"OAK
20"
22"
1"OAK
6"HW
2"ORN
3"ORN
30"POP
STOP
SSMH (1055)
TOP: 943.53
IN "A": 937.83
IN "B": 934.82
OUT: 934.78
SSMH (1274)
TOP: 939.15
IN "A": 928.74
IN "B": 929.03
OUT: 928.65
SSMH (1301)
TOP: 939.19
IN: 931.41
OUT: 931.36
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
CURB &
GUTTER
CURB &
GUTTER
LANDSCAPING
STONE
NO
PARKING
STOP
AHEAD
STOP &
STREETS
CONCRETE
PATCHSTOP
7/7"
DOG
5/7"
DOG
10"13"11"
MAG
5"6"5"
HW
6"3"
HW
AUTUMN
PARK
PARK
RULES
1/2"RB
CONCRETE
FLUME
CONCRETE
FLUME
1/2"CTP
1/2"RB
4"5"5"
HW
4' FENCE CL
STOP
1" OTP BENT
1/2" RB
4' CLF
PLANTER
BOX
1" METAL
ROD
INV:
931.01
INV:
930.61
INV:
932.50
INV:
931.89
LANDSCAPING
STONE
STONE
WALL
STONE
WALL
CONC.
WALLS
STONES &
CONCRETE
IN DITCH
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE AE ZONE AE
ZONE AE
ZONE AE
ZONE AE
MCCLAVE DRIVE
(60' R/W)
A U
TU
M
N D
R
IV
E (5
0' R
/W
ALLEN DRIVE
(50' R
/W
DEPTH
1'3"
DEPTH
4'4"
DEPTH
3'
DEPTH
1'8"
DEPTH
3'8"
DEPTH
4'3"
DEPTH
2'
DEPTH
2'9"
DEPTH
2'8"
DEPTH
4'8"
DEPTH
3'10"
DEPTH
3'10"
DEPTH
3'6"
DEPTH
2'3"
CONC.
WALL
CONC.
WALL
4"DIP
A
B
8"DIP
8"DIP
12"DIP
8"DIP
8"DIP
A B
CONCRETE
DRIVE
CONCRETE
DRIVECONCRETE
DRIVE
30"RCP 42"RCP
1/2"CTP
N/F
DEKALB COUNTY
PIN: 18 296 03 001
PB. 25 PG. 47N/F
BARRETT M. DOUGLAS
PIN: 18 296 11 010
DB. 4252 PG. 292
PB. 25 PG. 47
N/F
VITTORIO TORRISI, JR.
PIN: 18 296 10 022
DB. 24113 PG. 234
PB. 25 PG. 47
N/F
DINQUAN CHENG &
WEIJANE WONG CHENG
PIN: 18 296 08 001
DB. 7458 PG. 34
PB. 25 PG. 47
N/F
LAURA CAROLINE CANFIELD &
EUGENE FRANCIS ARMISTEAD
PIN: 18 296 08 002
DB. 26497 PG. 788
PB. 25 PG. 47
N/F
SCOTT BURESH
PIN: 18 296 08 003
DB. 30343 PG. 86
PB. 25 PG. 47
N/F
ABIGAIL M. TUCKER
PIN: 18 296 08 004
DB. 11474 PG. 288
PB. 25 PG. 47
N/F
CITY OF DORAVILLE
PIN: 18 296 08 005
DB. 4097 PG. 459
PB. 25 PG. 47
N/F
CITY OF DORAVILLE
PIN: 18 296 08 006
DB. 4097 PG. 459
PB. 25 PG. 47
CONCRETE
DRIVE
ZONE X
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
WATER METER TO
BE RELOCATED
UTILITY POLE TO BE
RELOCATED
WATER METER TO
BE RELOCATEDWATER METER TO BE
RELOCATED
MAILBOX TO BE
REMOVED / REPLACED
MAILBOX TO BE
REMOVED / REPLACED
MAILBOX AND
PLANTER BOX TO BE
REMOVED / REPLACED
DRIVEWAY APRONS TO BE
SAWCUT FOR DEMOLITION
DRIVEWAY APRONS TO BE
SAWCUT FOR DEMOLITION
EXISTING STOP SIGN
TO BE RELOCATED
AS NEEDED 9" POP TREE TO
BE REMOVED
SAW CUT PAVEMENT FOR PIPE
INSTALLATION
LIMITS TO BE ADJUSTED AS NEEDED
FOR CONSTRUCTION METHODS
NO PARKING SIGN
TO BE REMOVED
AND RELOCATED
GRANITE CURB TO
BE REMOVED AND
STORED FOR REUSE.
EX. HEADWALL TO BE
REMOVED (TO BE
TIMED APPROPRIATELY
WITH REPLACEMENT
INSTALLATION)
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
APPROX. LOCATION
MATERIAL STORAGE WITHIN
PARK PROPERTY AS
DESIGNATED BY THE CITY.
TO BE LOCATED OUTSIDE OF
STORM SEWER DITCH.
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \S
H
EE
TS
\C
2.
D
EM
O .d w g
L
AS
T
SA
VE
D
BY
: J
KW
O
N
2/ 4/
A
T 1:
P
M
PL
O
TT
ED
B
Y:
JK
W O
N
2/ 4/
A
T 5:
P
M
PA
PE
R
SI
ZE
: A
RC
H F
U
LL
B
LE
ED
D
(3 6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G T
O P
DF
.P
C3
PL
O T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
GENERAL DEMOLITION NOTES
1. CONTRACTOR TO INSTALL ALL APPROPRIATE EROSION CONTROL MEASURES, INCLUDING TREE PROTECTION FENCING, PRIOR TO
ANY DEMOLITION ACTIVITY TAKING PLACE.
2. CONTRACTOR TO ABIDE BY ALL APPLICABLE FEDERAL, STATE, AND LOCAL LAWS CONCERNING THE REMOVAL, DEMOLITION, AND/OR DISPOSAL OF POSSIBLE HARMFUL MATERIALS INCLUDING LEAD PAINT, ASBESTOS ETC. DURING ALL PHASES OF
CONSTRUCTION.
3. CONTRACTOR TO SAW CUT EXISTING PAVEMENT FULL DEPTH AT EDGE OF DEMOLITION LIMITS.
4. ALL ITEMS NOTED FOR REMOVAL/DEMOLITION SHALL BE REMOVED FROM THE SITE OR DISPOSED OF IN A LEGAL MANNER.
5. EXISTING INFORMATION IS BASED ON A SURVEY CONDUCTED BY TERRAMARK, DATED 09-22-2023. ALL SHOWN UTILITY LOCATIONS ARE APPROXIMATE AND SHOULD BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHOULD NOTIFY ENGINEER
IMMEDIATELY IF FIELD CONDITIONS DIFFER FROM ASSUMPTIONS MADE IN THESE PLANS.
6. THERE IS FLOODPLAIN ON THIS SITE PER FEMA FIRM MAP 13089C0019K, DATED 8/15/2019.
7. POLLUTION CONTROLS: USE WATER SPRINKLERS AND TEMPORARY ENCLOSURES TO LIMIT THE AMOUNT OF DUST AND DIRT RISING IN THE AIR TO THE LOWEST PRACTICAL LEVEL. DO NOT USE WATER WHEN IT MAY CREATE HAZARDOUS CONDITIONS, ICE, FLOODING, OR POLLUTION.
8. CLEAN ADJACENT STRUCTURES AND IMPROVEMENTS OF DUST, DIRT, AND DEBRIS CAUSED BY DEMOLITION OPERATIONS.
RETURN ADJACENT AREAS TO CONDITION EXISTING PRIOR TO THE START OF THE WORK.
9. COORDINATE WITH THE CORRESPONDING UTILITY COMPANY BEFORE REMOVING ANY UNDERGROUND OR OVERHEAD UTILITY
LINES AND TRANSFORMERS.
10. PRIOR TO DEMOLITION, THE SITE IS TO BE VISITED BY THE CONTRACTOR TO DETERMINE EXISTING CONDITIONS OF
STRUCTURE(S) TO BE REMOVED.
11. ITEMS OF SALVAGEABLE VALUE TO THE CONTRACTOR MAY BE REMOVED FROM THE STRUCTURE AS THE WORK PROGRESSES.
SALVAGED ITEMS MUST BE TRANSPORTED FROM THE SITE AS THEY ARE REMOVED. STORAGE OR SALE OF REMOVED ITEMS ON
THE SITE WILL NOT BE PERMITTED.
12. TRAFFIC: CONDUCT DEMOLITION OPERATIONS AND THE REMOVAL OF DEBRIS TO ENSURE MINIMUM INTERFERENCE WITH ROADS, STREETS, WALKS, AND ADJACENT OCCUPIED OR USED FACILITIES. OBTAIN ANY PERMITS FOR LANE CLOSURE IF
NECESSARY.
13. ENSURE THE SAFE PASSAGE OF PERSONS AROUND THE AREA OF DEMOLITION. CONDUCT OPERATIONS TO PREVENT INJURY TO
ADJACENT BUILDINGS, STRUCTURES, FACILITIES, AND PERSONS.
14. PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT FACILITIES BY DEMOLITION OPERATIONS AT NO COST TO OWNER.
15. CONTRACTOR SHALL NOTIFY ALL GOVERNMENTAL AGENCIES, HAVING JURISDICTION, PRIOR TO THE START OF ANY DEMOLITION WORK. ANY FINES AND/OR PENALTIES INCURRED DUE TO THE CONTRACTOR NOT CONTACTING ALL REQUIRED
GOVERNMENTAL AGENCIES PRIOR TO DEMOLITION SHALL BE PAID BY THE CONTRACTOR.
16. ALL LAND DISTURBANCE TO BE STABILIZED WITH VEGETATION UPON COMPLETION OF DEMOLITION.
17. ALL TREES TO REMAIN AND HAVE PROPER PROTECTION UNLESS APPROVED PLANS INDICATE OTHERWISE.
18. DUMPSTERS AND/OR TEMPORARY SANITARY FACILITIES SHALL NOT BE LOCATED IN STREET OR TREE PROTECTION AREA.
19. ADDITIONAL EROSION CONTROLS SHALL BE INSTALLED AS DEEMED NECESSARY BY THE ON-SITE INSPECTOR.
20. CONTRACTOR SHALL ADJUST AND/OR REPLACE ALL DAMAGED EXISTING CURBS OR CURB AND GUTTER ALONG PROPERTY FRONTAGE. ANY MISSING CURBS AND/OR GAPS DUE TO DRIVEWAY RELOCATIONS, WILL REQUIRE NEW CURBS TO BE INSTALLED
TO MATCH EXISTING
UTILITY CAUTION NOTE:
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATION OF THE UNDERGROUND UTILITIES, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION OF ALL UTILITIES SHOWN AS WELL AS THOSE NOT SHOWN WITHIN THE CONSTRUCTION LIMITS. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
DEMOLITION & EROSION LEGEND
EXISTING PAVING, CURB & GUTTER, DRIVEWAY AND
SIDEWALKS TO BE REMOVED
EXISTING STRUCTURES TO BE REMOVED
LIMITS OF DISTURBANCELOD
C2.00
DE
M
O
LI
TI
O
N P
LA
N
M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D O
RA
VI
LL
E, G A
JK
HLS
23-250006
ZO
N
IN
G
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
12/04/2023
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
HELEN SIMPSON, PE
LA
N
D
LO
T
DI
ST
RI
CT
PA
RC
EL
ID
1" = 20'
0' 10' 20' 30'
93793
9 93
W W
W
W W
W W
W W
W W
W
W
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W
W
W W
W W
W W
W W
W W
W
G
SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN
X
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FO
C
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC FOC
FO
C
FO
C
FO
C
FOC
FOC
FOC
FOC
FOC
FOC
FOC
FOC
17"POP
24"
9"POP
3"DOG
21"POP
19"POP
20"
20" 20"MAP
29"POP
18"
18"
10"
14"POP
9"HW
36"POP
12"POP
6"DOG
8"HW
19"
26"HW
15"
3"ORN
15"POP
5"DOG
15"
38"POP
9"OAK
13"
18"POP
17"
17"OAK
20"
22"
1"OAK
6"HW
2"ORN
3"ORN
30"POP
STOP
SSMH (1055)
TOP: 943.53
IN "A": 937.83
IN "B": 934.82
OUT: 934.78
SSMH (1274)
TOP: 939.15
IN "A": 928.74
IN "B": 929.03
OUT: 928.65
SSMH (1301)
TOP: 939.19
IN: 931.41
OUT: 931.36
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
GRANITE
HEADER
CURB
CURB &
GUTTER
CURB &
GUTTER
LANDSCAPING
STONE
NO
PARKING
STOP
AHEAD
STOP &
STREETS
CONCRETE
PATCHSTOP
7/7"
DOG
5/7"
DOG
10"13"11"
MAG
5"6"5"
HW
6"3"
HW
AUTUMN
PARK
PARK
RULES
1/2"RB
CONCRETE
FLUME
CONCRETE
FLUME
1/2"CTP
1/2"RB
4"5"5"
HW
4' FENCE CL
STOP
1" OTP BENT
1/2" RB
4' CLF
PLANTER
BOX
1" METAL
ROD
INV:
931.01
INV:
930.61
INV:
932.50
INV:
931.89
LANDSCAPING
STONE
STONE
WALL
STONE
WALL
CONC.
WALLS
STONES &
CONCRETE
IN DITCH
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE X
ZONE AE ZONE AE
ZONE AE
ZONE AE
ZONE AE
MCCLAVE DRIVE
(60' R/W)
A U
TU
M
N D
R
IV
E (5
0' R
/W
ALLEN DRIVE
(50' R
/W
DEPTH
1'3"
DEPTH
4'4"
DEPTH
3'
DEPTH
1'8"
DEPTH
3'8"
DEPTH
4'3"
DEPTH
2'
DEPTH
2'9"
DEPTH
2'8"
DEPTH
4'8"
DEPTH
3'10"
DEPTH
3'10"
DEPTH
3'6"
DEPTH
2'3"
CONC.
WALL
CONC.
WALL
4"DIP
A
B
8"DIP
8"DIP
12"DIP
8"DIP
8"DIP
A B
CONCRETE
DRIVE
CONCRETE
DRIVECONCRETE
DRIVE
30"RCP 42"RCP
1/2"CTP
N/F
DEKALB COUNTY
PIN: 18 296 03 001
PB. 25 PG. 47N/F
BARRETT M. DOUGLAS
PIN: 18 296 11 010
DB. 4252 PG. 292
PB. 25 PG. 47
N/F
VITTORIO TORRISI, JR.
PIN: 18 296 10 022
DB. 24113 PG. 234
PB. 25 PG. 47
N/F
DINQUAN CHENG &
WEIJANE WONG CHENG
PIN: 18 296 08 001
DB. 7458 PG. 34
PB. 25 PG. 47
N/F
LAURA CAROLINE CANFIELD &
EUGENE FRANCIS ARMISTEAD
PIN: 18 296 08 002
DB. 26497 PG. 788
PB. 25 PG. 47
N/F
SCOTT BURESH
PIN: 18 296 08 003
DB. 30343 PG. 86
PB. 25 PG. 47
N/F
ABIGAIL M. TUCKER
PIN: 18 296 08 004
DB. 11474 PG. 288
PB. 25 PG. 47
N/F
CITY OF DORAVILLE
PIN: 18 296 08 005
DB. 4097 PG. 459
PB. 25 PG. 47
N/F
CITY OF DORAVILLE
PIN: 18 296 08 006
DB. 4097 PG. 459
PB. 25 PG. 47
ST CB - 1
ST CB - 3
2+53
0+00
1+00
2+00
REPLACE EXISTING HEADWALL WITH
MODIFIED GDOT HEADWALL DETAIL
ST CB - 2
EXISTING CLEANOUT
EXISTING SANITARY
SEWER SUEA FOR GAS
CONCRETE
DRIVE
SUEA FOR GASP-1 ~ 30" RCP CL III
125 LF @ 2.59%
P-2 ~ 36" RCP CL III
105 LF @ 1.00%
P-3 ~ 36" RCP CL III
22 LF @ 1.00%
ST HW - 4
PARALLEL GAS LINE TO BE
RELOCATED AS NEEDED
ZONE X
APPROXIMATE LOCATION OF
EXISTING SPEED BUMP
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
DRIVEWAY APRONS TO BE
REPLACED
REPLACE ASPHALT AND
GRANITE CURB
( SEE NOTE AS NEEDED)
DRIVEWAY APRONS TO BE
REPLACED
REPAINT STOP BAR AS
NEEDED
LOD
LOD
LOD
LOD
LOD
LO
D
LO
D
LODLODLODLODLODLODLODLODLODLODLODLOD
LO
D
LO
D
LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD LOD
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
GENERAL GRADING NOTES
1. ALL CRITICAL SPOT GRADES ALONG CURB ARE BOTTOM OF CURB ELEVATIONS UNLESS OTHERWISE SPECIFIED.
2. NO SLOPES ARE TO BE STEEPER THAN 2:1
3. ALL LAND DISTURBANCE TO BE STABILIZED WITH VEGETATION UPON COMPLETION OF DEMOLITION.
4. ALL TREES TO HAVE PROPER PROTECTION UNLESS APPROVED PLANS INDICATE OTHERWISE.
5. TOPOGRAPHIC SURVEY BY TERRAMARK, DATED 09-22-2023.
6. FLOOD PLAIN IS PRESENT ON THIS SITE PER FEMA FIRM MAP NUMBER 13089C0019K, DATED 8/15/2019.
7. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE ACCOMPLISHED PRIOR TO ANY OTHER CONSTRUCTION ON THE SITE AND
MAINTAINED UNTIL PERMANENT GROUND COVER IS ESTABLISHED.
8. OWNER IS RESPONSIBLE FOR MAINTENANCE OF ALL STORM SEWER ON PRIVATE PROPERTY.
9. THE OWNER IS RESPONSIBLE FOR OBTAINING ANY NECESSARY AGREEMENTS FROM ADJACENT PROPERTY OWNERS IN ORDER TO PERFORM THE REQUIRED OFFSITE WORK, INCLUDING, STORM DRAINAGE, CURB AND GUTTER AND PAVEMENT TIE-INS AND GRADING.
10. VERTICAL DEPTH OF ALL DRY AND PRESSURIZED UTILITIES IS UNKNOWN. CONTRACTOR TO NOTIFY OWNER AND ENGINEER IMMEDIATELY IF
ANY CONFLICTS ARE FOUND.
11. ALL CLEANOUTS LOCATED IN PAVEMENT TO HAVE TRAFFIC RATED LIDS
UTILITY CAUTION NOTE:
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS.
THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATION OF THE UNDERGROUND UTILITIES, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION OF ALL UTILITIES SHOWN AS WELL AS THOSE NOT SHOWN WITHIN THE CONSTRUCTION LIMITS. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
GENERAL STORM NOTES
1. MINIMUM 2' COVER OVER ALL PIPES IN NON-TRAFFIC AREAS. 4' MINIMUM COVER UNDER PAVEMENT AND TRAFFIC AREAS.
2. FITTINGS AND CONNECTIONS PER MANUFACTURERS SPECIFICATIONS
3. PIPE BEDDING PER CITY/COUNTY STANDARD DETAIL ON C9.01
4. APPROXIMATE LOCATION OF ROOF LEADERS ARE SHOWN ON THE PLANS OF THIS PERMIT SET. SIZE OF PIPE TO BE DETERMINED.
CONTRACTOR TO CONTACT ENGINEER IF CONFLICT OCCURS.
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \C
O N
CE
PT
S\
CO
N
CE
PT
G
RA
DI
N G
.d w g L
AS
T
SA
VE
D
BY
: J
KW
O N
2/
4/
A T
5:
P M
PL
O
TT
ED
B Y:
JK
W
O N
2/
4/
A T
5:
P M
PA
PE
R
SI
ZE
: A
RC
H
F U
LL
B
LE
ED
D (3
6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G
T O
P
DF
.P C3
PL
O
T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
JK
HLS
23-250006
TB
D
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
HELEN SIMPSON, PE
TB
D
TB
D TB
D
1" = 20'
0' 10' 20' 30'
GRADING NOTES:
GRANITE CURB WILL BE REUSED / CITY SUPPLY WILL BE USED FOR THE RE-ESTABLISHMENT.
DR
AI
N
AG
E
PL
AN
M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D O
RA
VI
LL
E, G A
12/04/2023
C3.00
GENERAL CONSTRUCTON NOTES:
ALL CONSTRUCTION TO BE CONTAINED WITHIN THE McCLAVE DRIVE RIGHT OF WAY AND THE CITY OF DORAVILLE PROPERTY.
HORIZONTAL SCALE: 1"=20'
VERTICAL SCALE: 1"=5'
STORM PROFILE
-1+00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
P-3 - 36" RCP CL III
22 LF @ 1.00%
CB
S
IN
G
LE
W
IN
G
G
DO
T
D
IN
V
IN
6" R
CP
C
L
III
1.
' F
RO
M (S
T
CB
2)
IN
V
O U
T
" R
CP
C L
III
: 9
.7
2' T
O (S
T H
W
4)ST CB - 3
ST
A:
+3
0.
RI
M
E L:
.1 2'
H
EI
G H
T:
.4 0'
P-1 - 30" RCP CL III
125 LF @ 2.59%
CB
S
IN
G
LE
W
IN
G
G
DO
T
D
IN
V
O U
T
" R
CP
C L
III
: 9
.7
1' T
O (S
T
CB
2)
ST CB - 1
ST
A:
+0
0.
RI
M
E L:
.3 4'
H
EI
G H
T:
.6 3'
2.
EX. SSWR P1
12"DIP
STA: 3+06.92
DI-22 TO
INV. 928.40
CB
S
IN
G
LE
W
IN
G G
DO
T
D
IN
V
IN
0" R
CP
C
L
III
3.
' F
RO
M (S
T
CB
1)
IN
V
O U
T
" R
CP
C L
III
: 9
.9
6' T
O (S
T
CB
3)
ST CB - 2
ST
A:
+2
5.
RI
M
E L:
.4 9'
H
EI
G H
T:
.5 3'
P-2 - 36" RCP CL III
105 LF @ 1.00%
H
EA
DW
AL
L M
O
DI
FI
ED
G
DO
T
IN
V
IN
6" R
CO
C
L
III
1.
' F
RO
M (S
T
CB
5)
IN
V
IN
2" E
XI
ST
IN
G
S
TR
M P
IP
E:
.6 1'
IN
V
IN
0" E
XI
ST
IN
G
S
TR
M P
IP
E:
.0 1'
ST
A:
+3
5.
RI
M
E L:
.2 5'
H
EI
G H
T:
.5
P-3 - 36" RCP CL III
22 LF @ 1.00%
ST HW - 4
PROPOSED
30'X15' RIP
RAP,
CONNECT
TO EXISTING
EX. TOP OF WALL 938.34'
EX. TOP OF WALL 936.6'
EX. TOP OF WALL 935.61'
EX. TOP OF WALL 935.61'
EX. BOTTOM 929.56'
EX. BOTTOM 928.89'
EX. BOTTOM 928.52'
EX. BOTTOM 932.12'
EX. 30" PIPE
INV: 931.01'
EX. 42" PIPE
INV: 930.61
PROPOSED 36" PIPE
INV: 931.50'
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
GENERAL GRADING NOTES
1. ALL CRITICAL SPOT GRADES ALONG CURB ARE BOTTOM OF CURB ELEVATIONS UNLESS OTHERWISE SPECIFIED.
2. NO SLOPES ARE TO BE STEEPER THAN 2:1
3. ALL LAND DISTURBANCE TO BE STABILIZED WITH VEGETATION UPON COMPLETION OF DEMOLITION.
4. ALL TREES TO HAVE PROPER PROTECTION UNLESS APPROVED PLANS INDICATE OTHERWISE.
5. TOPOGRAPHIC SURVEY BY TERRAMARK, DATED 09-22-2023.
6. FLOOD PLAIN IS PRESENT ON THIS SITE PER FEMA FIRM MAP NUMBER 13089C0019K, DATED 8/15/2019.
7. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE ACCOMPLISHED PRIOR TO ANY OTHER CONSTRUCTION ON THE SITE AND
MAINTAINED UNTIL PERMANENT GROUND COVER IS ESTABLISHED.
8. OWNER IS RESPONSIBLE FOR MAINTENANCE OF ALL STORM SEWER ON PRIVATE PROPERTY.
9. THE OWNER IS RESPONSIBLE FOR OBTAINING ANY NECESSARY AGREEMENTS FROM ADJACENT PROPERTY OWNERS IN ORDER TO PERFORM THE REQUIRED OFFSITE WORK, INCLUDING, STORM DRAINAGE, CURB AND GUTTER AND PAVEMENT TIE-INS AND GRADING.
10. VERTICAL DEPTH OF ALL DRY AND PRESSURIZED UTILITIES IS UNKNOWN. CONTRACTOR TO NOTIFY OWNER AND ENGINEER IMMEDIATELY IF
ANY CONFLICTS ARE FOUND.
11. ALL CLEANOUTS LOCATED IN PAVEMENT TO HAVE TRAFFIC RATED LIDS
UTILITY CAUTION NOTE:
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS.
THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATION OF THE UNDERGROUND UTILITIES, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION OF ALL UTILITIES SHOWN AS WELL AS THOSE NOT SHOWN WITHIN THE CONSTRUCTION LIMITS. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
GENERAL STORM NOTES
1. MINIMUM 2' COVER OVER ALL PIPES
2. FITTINGS AND CONNECTIONS PER MANUFACTURERS SPECIFICATIONS
3. PIPE BEDDING PER CITY/COUNTY STANDARD DETAIL ON C9.01
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \C
O N
CE
PT
S\
CO
N
CE
PT
G
RA
DI
N G
.d w g L
AS
T
SA
VE
D
BY
: J
KW
O N
2/
4/
A T
5:
P M
PL
O
TT
ED
B Y:
JK
W
O N
2/
4/
A T
5:
P M
PA
PE
R
SI
ZE
: A
RC
H
F U
LL
B
LE
ED
D (3
6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G
T O
P
DF
.P C3
PL
O
T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
JK
HLS
23-250006
TB
D
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
HELEN SIMPSON, PE
TB
D
TB
D TB
D
N/A
MODIFIED OUTLET HEADWALL DETAIL
ALL POINTS ARE APPROXIMATE, AND THE ELEVATION
POINTS ARE BASED ON THE SURVEY FILE.
EXISTING ELEVATIONS FROM FIELD SURVEY - TO BE
VERIFIED BY CONTRACTOR PRIOR TO CONSTRUCTION.
EXISTING SURFACE
100-YR HGL LINE
EX. HEADWALL (HW-4)
TO BE REPLACED WITH MODIFIED GDOT STRUCTURE
WITH ADDED 24" PIPE CONNECTION IN WEST WING WALL
ST
O
RM
P
RO
FI
LE
A
N D
DE
TA
IL
S
12/04/2023
C3.10
M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D O
RA
VI
LL
E, G A
SHEET
PROJECT MANAGER:
DRAWN BY:
CHECKED BY:
ZO
N
IN
G
LA
N D
LO
T:
TA
X
DI
ST
RI
CT
TA
X
PA
RC
EL
ID
SCALE:
DATE:
RE
VI
SI
O
N S
N O
DA
TE
COPYRIGHT ©2023 BY LOWE ENGINEERS,
LLC. ALL RIGHTS RESERVED. THIS
DOCUMENT IS THE PROPERTY OF LOWE
ENGINEERS, LLC AND IS TO BE USED ONLY
FOR THE PROJECT SPECIFIED HEREIN. IT IS
NOT TO BE USED ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT, IN
WHOLE OR IN PART, EXCEPT BY
EXPRESSED WRITTEN AGREEMENT WITH
LOWE ENGINEERS, LLC.
THIS MEDIA SHOULD NOT BE
CONSIDERED A CERTIFIED DOCUMENT
UNLESS IT IS PROPERLY SIGNED AND
SEALED
CONSTRUCTION SITE SAFETY IS THE SOLE
RESPONSIBILITY OF THE CONTRACTOR;
NEITHER THE OWNER NOR THE ENGINEER
SHALL BE EXPECTED TO ASSUME ANY
RESPONSIBILITY FOR SAFETY OF THE
WORK, OF PERSONS ENGAGED IN THE
WORK, OF ANY NEARBY STRUCTURES, OR
ANY OTHER PERSON
PROJECT #:
DE
SC
RI
PT
IO
N
H
AM
M O
N D
DR
IV
E, S
U
IT
E
AT
LA
N
TA
, G
A
0.
7.
PR
EP
AR
ED
B Y:
NORTH
12/04/2023
GENERAL GRADING NOTES
1. ALL CRITICAL SPOT GRADES ALONG CURB ARE BOTTOM OF CURB ELEVATIONS UNLESS OTHERWISE SPECIFIED.
2. NO SLOPES ARE TO BE STEEPER THAN 2:1
3. ALL LAND DISTURBANCE TO BE STABILIZED WITH VEGETATION UPON COMPLETION OF DEMOLITION.
4. ALL TREES TO HAVE PROPER PROTECTION UNLESS APPROVED PLANS INDICATE OTHERWISE.
5. TOPOGRAPHIC SURVEY BY TERRAMARK, DATED 09-22-2023.
6. FLOOD PLAIN IS PRESENT ON THIS SITE PER FEMA FIRM MAP NUMBER 13089C0019K, DATED 8/15/2019.
7. EROSION AND SEDIMENT CONTROL MEASURES ARE TO BE ACCOMPLISHED PRIOR TO ANY OTHER CONSTRUCTION ON THE SITE AND
MAINTAINED UNTIL PERMANENT GROUND COVER IS ESTABLISHED.
8. OWNER IS RESPONSIBLE FOR MAINTENANCE OF ALL STORM SEWER ON PRIVATE PROPERTY.
9. THE OWNER IS RESPONSIBLE FOR OBTAINING ANY NECESSARY AGREEMENTS FROM ADJACENT PROPERTY OWNERS IN ORDER TO PERFORM THE REQUIRED OFFSITE WORK, INCLUDING, STORM DRAINAGE, CURB AND GUTTER AND PAVEMENT TIE-INS AND GRADING.
10. VERTICAL DEPTH OF ALL DRY AND PRESSURIZED UTILITIES IS UNKNOWN. CONTRACTOR TO NOTIFY OWNER AND ENGINEER IMMEDIATELY IF
ANY CONFLICTS ARE FOUND.
11. ALL CLEANOUTS LOCATED IN PAVEMENT TO HAVE TRAFFIC RATED LIDS
UTILITY CAUTION NOTE:
THE UTILITIES SHOWN ARE SHOWN FOR THE CONTRACTOR'S CONVENIENCE ONLY. THERE MAY BE OTHER UTILITIES NOT SHOWN ON THESE PLANS.
THE ENGINEER ASSUMES NO RESPONSIBILITY FOR THE LOCATION OF THE UNDERGROUND UTILITIES, AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY LOCATION OF ALL UTILITIES SHOWN AS WELL AS THOSE NOT SHOWN WITHIN THE CONSTRUCTION LIMITS. ALL DAMAGE MADE TO EXISTING UTILITIES BY THE CONTRACTOR SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
GENERAL STORM NOTES
1. MINIMUM 2' COVER OVER ALL PIPES
2. FITTINGS AND CONNECTIONS PER MANUFACTURERS SPECIFICATIONS
3. PIPE BEDDING PER CITY/COUNTY STANDARD DETAIL ON C9.01
FI
LE
N
AM
E:
Z
-2
M cC la ve
D riv e Dr ai na ge Im pr ov em en ts \6
DW
G \C
O N
CE
PT
S\
CO
N
CE
PT
G
RA
DI
N G
.d w g L
AS
T
SA
VE
D
BY
: J
KW
O N
2/
4/
A T
5:
P M
PL
O
TT
ED
B Y:
JK
W
O N
2/
4/
A T
5:
P M
PA
PE
R
SI
ZE
: A
RC
H
F U
LL
B
LE
ED
D (3
6.
X
4.
IN
CH
ES
DE
VI
CE
DW
G
T O
P
DF
.P C3
PL
O
T
ST
YL
E:
C
IV
IL
-S
IT
E.
CT
B
JK
HLS
23-250006
TB
D
CI
TY
O F
DO
RA
VI
LL
E
P
AR
K
AV
EN
U E
DO
RA
VI
LL
E, G
A
PH
O
N E:
-2
-4
H
O U
R
CO
N
TA
CT
CH
RI
S
LA
FL
EU
R:
-2
-4
HELEN SIMPSON, PE
TB
D
TB
D TB
D
N/A
ST
O
RM
C
AL
CU
LA
TI
O N
12/04/2023
C3.20
M cC
LA
VE
D
RI
VE
D
RA
IN
AG
E
IM
PR
O
VE
M
EN
TS
M cC
LA
VE
D
RI
VE
D O
RA
VI
LL
E, G A
25-YR STORMWATER CALCULATION
100-YR STORMWATER CALCULATION
DRAIN…
This is the start of the file's text. The full file is on GovTribe.