This document is an addendum to the bid documents for a construction project for the Michigan Department of Health and Human Services' Shawono Center in Grayling, Michigan. The project involves upgrading the youth bathrooms and showers in the facility, including demolition, installation of new finishes, plumbing fixtures, lighting, and other associated work. Key changes in this addendum include revisions to demolition and renovation details, updated electrical specifications, and clarification on prevailing wage requirements. The bid due date has been revised to February 21, 2024 at 2:00 PM Eastern time.
The addendum also includes a room finish schedule, reflected ceiling plans, and interior elevations providing additional detail on the project. The construction project is funded by the State of Michigan, and contractors must comply with applicable state prevailing wage requirements, including maintaining payroll records for inspection. No other pricing terms, set asides, incumbent information, or funding sources are provided in the addendum.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum 1_Shawono Showers DRAWINGS.pdf | ||
| Shawono Specs.pdf | ||
| Shawono Advertisement.pdf | ||
| Shawono Plans.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADDENDUM 1
757 S. WISCONSIN AVENUE ▪ GAYLORD MI 49735
p h o n e 989.705.8400 ▪ f a x 989.705.8403
-1-
Addendum Number: 1
Date: 2.8.24
Project Name: HHS – Shawono Center – Upgrade Youth Bathrooms / Showers
SG Project Number: 523191 DTMB File No.: 491/23073.TYC Bid Date: 2.14.24 (THIS HAS BEEN REVISED to 2/21/2024 at 2:00 Eastern time)
This Addendum is being issued for the purpose of clarifying and/or modifying the original Bidding Documents and shall take precedence over them. Each Bidder’s proposal shall include the Work described herein. All requirements contained in the Contract Documents shall apply to this Addendum. All incidental work necessary to complete the Work shall be included in the Contractor’s quotation even though not particularly mentioned. Parts of the Specifications and Drawings referred to herein supersede previously issued data and form a part of this Addendum.
CLARIFICATIONS:
1. Sheet CS-000 – No changes
2. Sheet CS-001 – No Changes
3. Sheet AD-101 – Revise Demolition Key Note #9 to include ‘toggle switches’.
4. Sheet A-111 – Revise Renovation Key Notes:
a. #3 – Remove walls and add ‘both sides of the door’.
b. #10 – Add ‘toggle switch’.
5. Sheet A-111 -Revise plans to indicate new ceiling mounted light fixtures.
6. Sheet A-601 & A-602 – Revise wall tile to entirely cover all walls.
7. Sheet A-701 – Revise Room Finish Schedule to indicate no wall base tile and complete coverage of walls to be tile.
8. Sheet A-801 – Revise to indicate ceiling mounted light fixtures in Rooms #121, 132, 133, 160 & 161.
9. DC Specifications – State mandated revision regarding prevailing wages.
10. Provide electrical specifications: 26 2726 – Wiring Devices and 26 5119 – LED Interior Lighting
ATTACHMENTS:
The following documents are a part of this Addendum:
1. Complete plan set.
2. DC Spec Revisions Effective 2/14/24
3. Electrical specifications: 26 2726 – Wiring Devices and 26 5119 – LED Interior Lighting
END OF ADDENDUM
4. Bid schedule- listing the provisional allowance.
Know what's below.
before you dig.Call
R
GENERAL NOTES
THIS PROJECT CONSISTS OF PLUMBING FIXTURE, MECHANICAL
GRILL, VALVE BOX AND FLOOR, WALL, AND (AS INDICATED ON
DRAWINGS) FINISH REPLACEMENTS.
THE BUILDING STRUCTURE IS NOT TO BE ALTERED FOR THIS
PROJECT.
THE EXISTING MECHANICAL SYSTEM IS NOT TO BE ALTERED FOR
THIS PROJECT, U.N.O.
THE EXISTING PLUMBING SYSTEM IS NOT TO BE ALTERED FOR
THIS PROJECT, U.N.O.
THE EXISTING FIRE PROTECTION SYSTEM IS NOT TO BE ALTERED
FOR THIS PROJECT. THE FACILITY HAS FIRE DETECTION
THROUGH OUT THE ENTIRE FACILITY. EXISTING FIRE SPRINKLER
HEADS IN THE AREAS OF CONSTRUCTION SHALL BE CLEANED
AND REINSTALLED.
THE EXISTING ELECTRICAL SYSTEM IS NOT TO BE ALTERED FOR
THIS PROJECT. THE ELECTRICAL WORK IS RESTRICTED TO
LIGHTING FIXTURE AND CONTROLS REPLACEMENT AS INDICATED
ON THE DRAWINGS AND SPECIFICATIONS.
THESE NOTES ARE GENERAL REFERENCE. WHERE CONFLICTS
EXIST BETWEEN THESE NOTES AND CURRENT CODES THE MORE
STRINGENT REQUIREMENTS SHALL PREVAIL.
BEFORE BEGINNING WORK AT THIS SITE, AND THROUGHOUT THE
SOURCE OF THE WORK, INSPECT AND VERIFY THE LOCATION AND
CONDITION OF EVERY ITEM EFFECTED BY THE WORK UNDER THIS
CONTRACT. REPORT ANY DISCREPANCIES TO THE ARCHITECT
BEFORE PERFORMING ANY WORK RELATED TO THE INSPECTION.
TRADE, PRODUCT, OR MANUFACTURER'S NAMES, OR CATALOG
NUMBERS SHOWN ON THE DRAWINGS FOR NEW PRODUCTS ARE
TO ESTABLISH QUALITY REQUIRED. IN EACH CASE ADD, BY
INFERENCE, AFTER TRADE, PRODUCT OR MANUFACTURER'S
NAME, THE PHRASE, "OR APPROVED EQUAL".
ALL TRADES SHALL CONFORM WITH ALL APPLICABLE FEDERAL,
STATE, LOCAL, AND OSHA CODES, RULES AND REGULATIONS. IN
CASE OF CONFLICT, THE MOST STRINGENT SHALL APPLY.
LAKE
MICHIGAN
LAKE
SUPERIOR
LAKE
ERIE
LAKE
HURON
ARROWHEAD ROAD
S. HO
W
ES LAKE RO
AD
SHAWONO CENTER
CS-000
RL
TM
TM
COVER SHEEET
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND
CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE
PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2023
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
SCALE:
N
LOCATION MAP
NO SCALE
CODE INFORMATION
BUILDING CODE: 2015 MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS/ 2015 MICHIGAN BUILDING CODE
AND 2012 NFPA 101 LIFE SAFETY CODE (AS APPLICABLE)
PLUMBING CODE MICHIGAN PLUMBING CODE 2018
MECHANICAL CODE MICHIGAN MECHANICAL CODE 2015
ELECTRICAL CODE MICHIGAN ELECTRICAL CODE 2017, INCORPORATING THE 2017 NEC W/ MICHIGAN PART 8 RULES
CONSTRUCTION CLASSIFICATION
MBC/NFPA: IIB (SPRINKLERED)
OCCUPANCY GROUP: EXIST.- MIXED OCCUPANCY, SEPARATED; A-3 (ASSEMBLY), B (BUSINESS), S-2 (LOW-HAZARD STORAGE).
OCCUPANT LOAD 150
PROJECT INFORMATION
SITE AREA:
EXISTING: N/A- EXISTING FACILITY
ZONING:
EXISTING: N/A
PARKING: EXISTING - NO INCREASE IN PARKING PROPOSED
SITE DATA
GROSS AREA - EXISTING FACILITY = 44,349 S.F.
AREA IN SCOPE OF WORK = 466 S.F.
BUILDING DATA
DEPARTMENT OF HEALTH AND HUMAN SERVICES
SHAWONO CENTER - UPGRADE YOUTH
BATHROOMS / SHOWERS
DTMB FILE NO. 491/23073.TYC
10 N. HOWES LAKE ROAD
GRAYLING MICHIGAN
GENERAL
SHEET INDEX
ARCHITECTURAL
AD-101 DEMOLITION FLOOR PLANS
A-111 PARTIAL FLOOR PLANS SHOWER ROOMS
A-601 INTERIOR ELEVATIONS
A-602 INTERIOR ELEVATIONS
A-701 ROOM FINISH SCHEDULE
A-801 REFLECTED CEILING PLANS
CS-000 COVER SHEET
CS-001 KEY PLAN, SYMBOL INDEX, MOUNTING HEIGHTS, NOTES
AutoCAD SHX Text
SCHOOLCRAFT
AutoCAD SHX Text
MANISTEE
AutoCAD SHX Text
OCEANA
AutoCAD SHX Text
MUSKEGON
AutoCAD SHX Text
MASON
AutoCAD SHX Text
BERRIEN
AutoCAD SHX Text
GOGEBIC
AutoCAD SHX Text
DICKINSON
AutoCAD SHX Text
MENOMINEE
AutoCAD SHX Text
DELTA
AutoCAD SHX Text
ONTONAGON
AutoCAD SHX Text
IRON
AutoCAD SHX Text
BARAGA
AutoCAD SHX Text
HOUGHTON
AutoCAD SHX Text
KEWEENAW
AutoCAD SHX Text
MARQUETTE
AutoCAD SHX Text
ALGER
AutoCAD SHX Text
ST. CLAIR
AutoCAD SHX Text
HILLSDALE
AutoCAD SHX Text
CASS
AutoCAD SHX Text
ST. JOSEPH
AutoCAD SHX Text
BRANCH
AutoCAD SHX Text
LENAWEE
AutoCAD SHX Text
MONROE
AutoCAD SHX Text
GLADWIN
AutoCAD SHX Text
MIDLAND
AutoCAD SHX Text
JACKSON
AutoCAD SHX Text
BARRY
AutoCAD SHX Text
VAN BUREN
AutoCAD SHX Text
ALLEGAN
AutoCAD SHX Text
KALAMAZOO
AutoCAD SHX Text
OTTAWA
AutoCAD SHX Text
KENT
AutoCAD SHX Text
EATON
AutoCAD SHX Text
CALHOUN
AutoCAD SHX Text
IONIA
AutoCAD SHX Text
CLINTON
AutoCAD SHX Text
MECOSTA
AutoCAD SHX Text
OSCEOLA
AutoCAD SHX Text
NEWAYGO
AutoCAD SHX Text
LAKE
AutoCAD SHX Text
ISABELLA
AutoCAD SHX Text
MONTCALM
AutoCAD SHX Text
GRATIOT
AutoCAD SHX Text
CLARE
AutoCAD SHX Text
INGHAM
AutoCAD SHX Text
WASHTENAW
AutoCAD SHX Text
LIVINGSTON
AutoCAD SHX Text
SHIAWASSEE
AutoCAD SHX Text
GENESEE
AutoCAD SHX Text
OAKLAND
AutoCAD SHX Text
WAYNE
AutoCAD SHX Text
LAPEER
AutoCAD SHX Text
MACOMB
AutoCAD SHX Text
TUSCOLA
AutoCAD SHX Text
SAGINAW
AutoCAD SHX Text
ARENAC
AutoCAD SHX Text
BAY
AutoCAD SHX Text
SANILAC
AutoCAD SHX Text
HURON
AutoCAD SHX Text
OTSEGO
AutoCAD SHX Text
CHALEVOIX
AutoCAD SHX Text
EMMET
AutoCAD SHX Text
ANTRIM
AutoCAD SHX Text
CHEBOYGAN
AutoCAD SHX Text
GRAND TRAVERSE
AutoCAD SHX Text
WEXFORD
AutoCAD SHX Text
LELANAU
AutoCAD SHX Text
OGEMAW
AutoCAD SHX Text
BENZIE
AutoCAD SHX Text
OSCODA
AutoCAD SHX Text
MISSAUKEE
AutoCAD SHX Text
ROSCOMMON
AutoCAD SHX Text
KALKASKA
AutoCAD SHX Text
PRESQUE ISLE
AutoCAD SHX Text
CRAWFORD
AutoCAD SHX Text
LUCE
AutoCAD SHX Text
MACKINAC
AutoCAD SHX Text
CHIPPEWA
AutoCAD SHX Text
IOSCO
AutoCAD SHX Text
MONTMORENCY
AutoCAD SHX Text
ALCONA
AutoCAD SHX Text
ALPENA
AutoCAD SHX Text C
1. WHEN MOUNTING MULTIPLE DEVICES FROM DIFFERENT
TRADES IN THE SAME LOCATION (SUCH AS LIGHTING
SWITCHES, LOW VOLTAGE, THERMOSTATS, ETC), THEIR
ARRANGEMENT MUST BE IN ACCORDANCE WITH THE
FOLLOWING:
1.1. LOCATE DEVICES AS SHOWN ON THE
ARCHITECTURAL PLANS, ELEVATIONS OR SECTIONS.
1.2. WHEN SHOWN ON MECHANICAL OR ELECTRICAL
DRAWINGS, BUT NOT ON ARCHITECTURAL
DRAWINGS, DEVICES MUST BE UNIFORMLY AND
SYMMETRICALLY MOUNTED. VERTICALLY ALIGN
DEVICES MOUNTED AT HEIGHTS INDICATED, UNLESS
SEPARATED HORIZONTALLY BY A MINIMUM OF 24".
1.3. DEVICES INSTALLED IN MASONRY MUST BE FLUSH
WITH THE FINAL SURFACE.
1.4. IF THE CONTRACTOR HAS ANY DOUBTS REGARDING
THE LOCATION OF DEVICES, THE CONTRACTOR
MUST CONSULT WITH THE ARCHITECT PRIOR TO
ROUGHING-IN.
1.5. AT MULTIPLE SWITCHES, GANG W/ SINGLE COVER
PLATE.
2. DEVIATIONS FROM THE ABOVE INSTRUCTIONS WITHOUT
PRIOR APPROVAL BY THE ARCHITECT MUST BE
CORRECTED BY THE INSTALLING CONTRACTOR. ANY
COST, INCLUDING CUTTING & PATCHING, ENTAILED IN
THE REMOVAL, RELOCATION, AND REINSTALLATION OF
ANY DEVICES WILL BE THE RESPONSIBILITY OF THAT
CONTRACTOR.
GENERAL NOTES FOR
LOCATION OF DEVICES
CL
CLSC2
A # xx xx xx xx
A
MATCH LINE
REFERENCE TAG
(GENERAL\TYPICAL
USE)
SECTION
REFERENCE
ELEVATION
REFERENCE
(INTERIOR and\or
EXTERIOR)
ELEVATION
REFERENCE
(INTERIOR ONLY)
ENLARGED
REFERENCE
REVISION CLOUD &
DELTA
ID. & SHEET LOCATION
REFER TO XXX
ID. NUMBER
REFER TO SHEET
REFER TO XXX
REFER TO SHEET
ID. NUMBER
REFER TO SHEET
ELEVATION ID.
STRUCTURAL
GRID
ALIGN
CONSTRUCTION
ELEVATION, WORK
POINT
KEY NOTE
ROOM
IDENTIFICATION
WINDOW
IDENTIFICATION
DOOR
IDENTIFICATION
FINISH
IDENTIFICATION
CEILING FINISH/
HEIGHT
000'
T \ SLAB
ROOM CODE
WINDOW ID. NO.
DOOR ID. NO.
MATERIAL
COLOR
INDEX TO DRAWING SYMBOLS
XXX #'-##"
NEW COLUMN LINE
EXISTING COLUMN LINE
PARTITION
IDENTIFICATION
OCCUPANT NAME
ROOM NAME
150 SF
150 SF (PFD)
ROOM NO.
USER REQUESTED AREA (NSF)
ROOM AREA (NSF)
ROOM NAME
CL
XX# XX#
##X EQUIPMENT
IDENTIFICATION
EXISTING NOTES
1. CONTRACTOR MUST VISIT THE SITE AND FAMILIARIZE HIMSELF
WITH ALL EXISTING CONDITIONS. VERIFY MEASUREMENTS WITH
CORRESPONDING CONSTRUCTION OR EXISTING CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK, AND NOTIFY THE
ARCHITECT IMMEDIATELY OF SIGNIFICANT DISCREPANCIES.
2. VERIFY ALL CONDITIONS COVERING OR AFFECTING THE
STRUCTURAL WORK; OBTAIN AND VERIFY ALL DIMENSIONS AND
ELEVATIONS TO ENSURE THE PROPER STRENGTH, FIT AND
LOCATION OF THE STRUCTURAL WORK; REPORT TO THE
ARCHITECT ANY AND ALL CONDITIONS WHICH MAY INTERFERE
WITH OR OTHERWISE AFFECT OR PREVENT THE PROPER
EXECUTION AND COMPLETION OF THE NEW WORK. ALL
DISCREPANCIES SHALL BE FULLY RESOLVED PRIOR TO
COMMENCING WORK.
3. EXISTING CONSTRUCTION NOT UNDERGOING ALTERATION IS TO
REMAIN UNDISTURBED, WHERE SUCH CONSTRUCTION IS
DISTURBED AS A RESULT OF THE OPERATIONS OF THIS
CONTRACT, IT MUST BE REPAIRED OR REPLACED BY THE
CONTRACTOR AS REQUIRED AND TO THE SATISFACTION OF THE
ARCHITECT.
4. WHERE THE EXISTING CONSTRUCTION IS TO BE ALTERED, OR
OTHERWISE DISTURBED, PROVIDE TEMPORARY AND/OR
PERMANENT BRACING AND SHORING AS MAY BE REQUIRED
BEFORE AND DURING OPERATIONS AND UNTIL THE WORK IS
SAFELY COMPLETED AND NO LONGER NEEDS SAME.
5. EACH CONTRACTOR SHALL PROVIDE ALL THE NECESSARY
SUPPORT, BRACING, SHORING, ETC. (TEMPORARY AND/OR
PERMANENT) OF BOTH NEW AND EXISTING CONSTRUCTION AS
REQUIRED FOR THE SAFE INSTALLATION OF THE NEW
CONSTRUCTION AND EQUIPMENT.
6. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND
STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS THE
CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION
PROCEDURE AND SEQUENCE, AND TO ENSURE THE SAFETY OF
THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION.
THIS INCLUDES THE ADDITION OF TEMPORARY BRACING, GUYS
OR TIE-DOWNS IF NECESSARY.
7. THE CONTRACTOR IS RESPONSIBLE FOR MEANS, METHODS,
SEQUENCES, AND PROCEDURES OF CONSTRUCTION.
8. PROVIDE FIRE WATCH DURING FIELD CUTTING AND WELDING
OPERATIONS, MEETING THE OWNER'S REQUIREMENTS.
9. ALL EXISTING STRUCTURAL MEMBERS TO REMAIN, U.N.O.
CONTINUED USE OF FACILITIES:
1. EACH CONTRACTOR SHALL AT ALL TIMES MAINTAIN A CLEAN AND
SAFE PASSAGEWAY FOR THE OWNER' S OPERATION AND
PERSONNEL IN EXISTING AREAS AND MAINTAIN CLEARANCES
ADJACENT TO AND IN CONNECTION WITH THE WORK
PERFORMED.
2. EACH CONTRACTOR SHALL EFFECTIVELY CONFINE DUST, DIRT
AND NOISE TO THE ACTUAL CONSTRUCTION AREA AS APPROVED
BY THE GENERAL CONTRACTOR IN ACCORDANCE WITH STATE OF
MICHIGAN REGULATIONS.
3. WORK SHALL, IF REQUIRED, BE CONSTRUCTED IN PHASES TO
ACCOMMODATE THE OWNER'S USE OF THE PREMISES DURING
THE CONSTRUCTION PERIOD AND FOR INSTALLATION OF HIS
EQUIPMENT. COORDINATE THE CONSTRUCTION SCHEDULE WITH
THE GENERAL CONTRACTOR AND OWNER'S REPRESENTATIVE.
4. DURING THE CONTRACTOR'S PERFORMANCE OF THE WORK OF
THIS CONTRACT, THE OWNER'S WILL CONTINUE TO OCCUPY THE
EXISTING BUILDING. INTERRUPTION OF BUILDING ACCESS AND
FACILITIES BY THE CONTRACTOR WILL NOT BE PERMITTED; TO
WHATEVER EXTENT SUCH INTERRUPTIONS MIGHT INTERFERE
WITH OWNER'S OCCUPANCY. LIMIT CONSTRUCTION OPERATIONS
TO THOSE METHODS AND PROCEDURES WHICH WILL NOT
ADVERSELY AND UNDULY EFFECT THE WORKING ENVIRONMENT
OF OWNER'S OCCUPIED SPACES, INCLUDING NOISE, DUST,
ODORS, AIR POLLUTION, AMBIENT DISCOMFORT, POOR LIGHTING,
HAZARDS AND OTHER UNDESIRABLE EFFECTS AND CONDITIONS.
COORDINATE AND SCHEDULE ALL WORK IN EXISTING BUILDING
WITH OWNER AND GENERAL CONTRACTOR.
SWITCHES
" M
AX
FLOOR MOUNTED
WATER CLOSETS
18" MIN.
NOTE: REFER TO INTERIOR
ELEVATIONS FOR SPECIFIC
FINISH TYPES AND LOCATIONS
FLUSH VALVE MUST
BE LOCATED ON THE
OPEN SIDE OF THE
WATER CLOSET
15" MIN.
5"
8"
5"
17" MIN.
COVER PIPES
TO PROTECT
AGAINST
CONTACT
WALL MOUNTED LAVATORY
12" X 18" STAINLESS
STEEL MIRROR
12" X 18" STAINLESS
STEEL MIRROR
MOUNTING HEIGHTS
CS-001
RL
TM
TM
KEY PLAN /
SYMBOL INDEX /
MOUNTING HGTS /
NOTES
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND
CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE
PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2023
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
SCALE:
N
KEY PLAN
1/16"=1'-0"
AD-101
AD-101
AD-101
AD-101
AD-101
AREA A
AREA B
AREA A
WEST
AREA A
EAST
AREA B AREA C
AREA C
AREA D
A-111
A-111
A-111
A-111
A-111
AE-158 AE-157 AE-142 AE-141
B-160
B-161
B-133 B-132
B-121
1. PROVIDE DUST MATS AT ALL CONSTRUCTION AREA
ENTRANCE AND EXIT LOCATIONS.
2. PERFORM ALL DEMOLITION WORK REQUIRED ON THE
EXISTING BUILDING AS CALLED FOR ON THE DRAWINGS
AND/OR AS REQUIRED TO ACCOMMODATE THE WORK.
3. CAP, PATCH AND REPAIR ALL HOLES AND SURFACES IN
WALLS, FLOORS AND CEILINGS WHERE MECHANICAL
AND ELECTRICAL ITEMS AND FIXTURES ARE REMOVED
AS A RESULT OF THE DEMOLITION OPERATIONS.
4. ALL EXISTING CONCRETE SLAB ON GRADE TO REMAIN
IS TO BE PATCHED, REPAIRED, AND/OR FILLED TO
MATCH EXISTING, PREPARE TO RECEIVE NEW FINISH.
5. DEMOLITION OF ALL PORTIONS OF THE STRUCTURE TO
BE REMOVED SHALL BE DONE WITH UTMOST CARE,
USING TOOLS AND METHODS SUBJECT TO OWNER'S
APPROVAL. ALL POSSIBLE CARE SHALL BE TAKEN TO
AVOID DAMAGING, SHOCK OR VIBRATION TO PORTIONS
OF EXISTING STRUCTURE TO REMAIN.
6. THE CONTRACTOR SHALL VERIFY THE EXISTENCE,
LOCATION AND ELEVATION OF EXISTING SEWERS,
DRAINS, ETC. IN DEMOLITION AREAS BEFORE
PROCEEDING WITH THE WORK, ALL DISCREPANCIES
SHALL BE DOCUMENTED AND REPORTED TO THE
ARCHITECT.
7. SAW CUT & REMOVE EXISTING CONCRETE SLAB FOR
PLACEMENT OF PLUMBING WORK, NECESSARY
CAPPING OF EXISTING LINES AND FOUNDATION WORK,
ETC. COORDINATE WITH STRUCTURAL ENGINEER AND
ARCHITECT.
8. SAWCUT AND REMOVE EXISTING MASONRY AS
REQUIRED AT EXISTING WALL OPENINGS TO ACCOM-
MODATE NEW MECHANICAL AND ELECTRICAL ITEMS.
9. REMOVE AND RELOCATE MECHANICAL AND
ELECTRICAL ITEMS, INCLUDING PIPING, FIXTURES,
EQUIPMENT, DUCTWORK, WIRING DEVICES, PANELS
AND ACCESSORIES AS REQUIRED.
10. ALL EXISTING CONSTRUCTION TO REMAIN U.N.O.
11. ALL EXISTING MATERIALS INDICATED TO REMAIN SHALL
BE REPAIRED TO MATCH EXISTING. MATERIALS
BEYOND REPAIR SHALL BE REPLACED TO MATCH
EXISTING.
12. PATCH AND PREPARE ALL DEMOLITION AREAS FOR
NEW FINISHES, REFER TO ARCHITECTURAL DRAWINGS.
13. REMOVE ALL MATERIALS AND DEBRIS CREATED
DURING THE DEMOLITION AND/OR CONSTRUCTION
PROCESS AND DISPOSE OFF SITE IN A SAFE AND
LEGAL MANNER.
DEMOLITION NOTES
REMOVE EXISTING WALL TILE TO CMU AND FLOOR TILE TO EXISTING
CONCRETE SLAB.
REMOVE EXISTING CEILING FINISH; PREP CEILING AND WALLS TO RECEIVE
NEW PAINT FINISH.
REMOVE EXISTING WATER CLOSETS AND FLUSH VALVES.
REMOVE EXISTING LAVATORIES AND FAUCETS.
REMOVE EXISTING SHOWER HEADS AND CONTROLS OR RECESSED SHOWER
UNITS AND PREP FOR INSTALLATION OF SURFACE MOUNTED SHOWER UNITS.
REMOVE EXISTING MIRRORS.
EXISTING BENCHES TO REMAIN
REMOVE EXISTING ABANDONED WALL ANCHORS.
REMOVE EXISTING ELECTRICAL SWITCH COVER PLATES.
REMOVE EXISTING LIGHT FIXTURES.
REMOVE EXISTING HVAC GRILLES AND DIFFUSERS FOR CLEANING.
REMOVE EXISTING GRAB BARS.
REMOVE EXISTING SPRINKLER HEAD ESCUTCHEONS FOR CLEANING.
REMOVE SPEAKER GRILLES FOR CLEANING
REMOVE EXISTING FLOOR DRAIN COVERS FOR CLEANING.
EXISTING FIRE/SMOKE DETECTORS ARE TO REMAIN. CONTRACTOR TO VERIFY
THAT THEY ARE FUNCTIONING PROPERLY
DEMOLITION KEY NOTES
DEMOLITION WALL LEGEND:
EXISTING WALL AND/OR
CONSTRUCTION TO REMAIN
REMOVE EXISTING WALL AND/OR
CONSTRUCTION
**NOTE: WALL LEGEND SHOWN FOR GRAPHICAL REFERENCE ONLY.
REFER TO WALL TYPES AND SECTIONS FOR ADDITIONAL DETAILS
AND INFORMATION.
EXISTING DOOR AND FRAME
ASSEMBLY TO REMAIN
AD-101
RL
TM
TM
DEMOLITION -
FLOOR PLANS
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 3
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
1 ENLARGED FLOOR PLAN - AREA A EAST2 ENLARGED FLOOR PLAN - AREA A EAST3 ENLARGED FLOOR PLAN - AREA B
SCALE:AD-101
4 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"SCALE:AD-101
5 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"
1 1 1 1
1 1
2 2 2 2
2 2
3 3
4 4
5 5
11 11
14 11
6 6
9 9 9 9
10 10
10 10
13 13 13
15 15
16 16
16 16
15 15
8 8
NN
NNN
AutoCAD SHX Text
SHOWER
SHOWER
SHOWER
SHOWER
PASSAGE
SHOWER
SHOWER
SHOWER
SHOWER
TOILET
SHOWER
121A
RENOVATION KEY NOTES
PROVIDE AND INSTALL CERAMIC FLOOR TILE. (REFER TO FINISH
SCHEDULE)
PROVIDE AND INSTALL CERAMIC WALL TILE. (REFER TO FINISH
SCHEDULE AND INTERIOR ELEVATIONS)
PAINT CEILING AND BOTH SIDES OF THE DOOR. (REFER TO FINISH
SCHEDULE AND INTERIOR ELEVATIONS)
PROVIDE AND INSTALL NEW WATER CLOSETS AND FLUSH VALVES.
PROVIDE AND INSTALL LAVATORIES AND FAUCETS.
PROVIDE AND INSTALL MIRRORS. (REFER TO INTERIOR ELEVATIONS
DWG.)
PROVIDE AND INSTALL SURFACE MOUNTED WALL SHOWER. (REFER
TO INTERIOR ELEVATIONS DWGS.)
REFINISH WOOD BENCHES AND SUPPORTS.
CLEAN AND REINSTALL DRAIN COVERS. PROVIDE AND INSTALL NEW
DRAIN COVERS AS REQUIRED AND APPROVED BY ARCHITECT
PROVIDE AND INSTALL TOGGLE SWITCHES AND STAINLESS STEEL
COVER PLATES.
PROVIDE AND INSTALL LIGHT FIXTURES W/LED LAMPS, 3,500K COLOR
TEMPERATURE THROUGHOUT.
CLEAN AND REINSTALL MECHANICAL GRILLES. REPLACE AS
REQUIRED AND APPROVED BY ARCHITECT.
CLEAN AND REINSTALL SPEAKER GRILLES. REPLACE AS REQUIRED
AND APPROVED BY ARCHITECT.
CLEAN AND REINSTALL SPRINKLER HEAD ESCUTCHEONS. REPLACE
AS REQUIRED AND APPROVED BY ARCHITECT. THE FIRE PROTECTION
SYSTEM SHALL BE INSPECTED AND CERTIFIED BY THE AUTHORITY
HAVING JURISDICTION.
EXISTING FIRE/SMOKE DETECTORS ARE TO REMAIN. CONTRACTOR
TO VERIFY THAT THEY ARE FUNCTIONING PROPERLY.
EXIST. WALL MOUNTED HEATER TO REMAIN. PAINT TO MATCH WALLS.
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
SCALE:A-101
1 ENLARGED FLOOR PLAN-AREA A EAST
1/2"=1'-0"SCALE:A-101
2 ENLARGED FLOOR PLAN-AREA A EAST
1/2"=1'-0"SCALE:A-101
3 ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"
SCALE:A-101
4 ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"SCALE:A-101
5 ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"
5 5 5
6 6
7 7
9 9
10 10
10101010
1 2
A-602
A-602
A-602 36A34A
A-601
27 A-602
A-602
22A
24A
A-601
A-601
02A
04A
A-601
10A
12A
A-601
A-601
14A
16A
A-601
11A-601
A-601
A-601 18A20A
HPHP HP
A-111
RL
TM
TM
PARTIAL FLOOR
PLANS SHOWER
ROOMS
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
3' -2
1'
-2
5' -8
4'-8"5'-8"
4'-8"8'-8"
3'-0"
3' -0
1'
-4
5' -8
4'-8"4'-8"
4'-8"4'-8"
6' -0
3'
-0
3' -0
1'
-4
5' -8
2'-4"2'-4" 2'-4"2'-4"
7' -4
9'-4"
3'-0"8"5'-0"8"
6' -4
8"
3' -0
5'-0"5'-0"
5'-0"5'-0"
'-0
2'-0"3'-0"
5' -0
8"
5' -0
10'-0"
3'-0"6'-4" 8"
5' -0
8"
5' -0
3' -0
2'
-0
2'-8"2'-0"
3' -0
4'
-4
HP
11 11
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
NN
NNN
'B'
'A'
'A'
'A'
'A'
'B'
'B''B'
'B'
'B'
'B' 'B'
'B'
'B'
9 9
9'A' 'A'
'A' 'A'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEV 1
ELEV 2
ELEV 2A
ELEV 3
ELEV 4
ELEV 4A
ELEV 5
ELEV 6
ELEV 7
ELEV 8
ELEV 9
ELEV 10
ELEV 10A
ELEV 11
ELEV 12
ELEV 12A
ELEV 13
ELEV 14A
ELEV 15
ELEV 14
ELEV 16
ELEV 16A
ELEV 18
ELEV 17
ELEV 18A
ELEV 19
ELEV 20
ELEV 20A
SHOWER
SHOWER
SHOWER
SHOWER
TOILET
SHOWER
121A
A-601
RL
TM
TM
INTERIOR
ELEVATIONS &
FLOOR TILE
LAYOUT
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
LIGATURE- RESISTANT
WALL SHOWER
WALL TILE- PWT
LIGHT FIXTURE
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT
WALL TILE- PWTWALL TILE- PWT
HM DOOR &
FRAME- PAINT
BOTH SIDES
LIGHT FIXTURE
SCALE:
SHOWER ROOM 141
1/4"=1'-0"
SCALE:
SHOWER ROOM 142
1/4"=1'-0"
SCALE:
SHOWER ROOM 157
1/4"=1'-0"
SCALE:
SHOWER ROOM 158
1/4"=1'-0"
SCALE:
SHOWER ROOM 121
1/4"=1'-0"
LIGHT FIXTURE
WALL TILE- PWT
LIGATURE-
RESISTANT
WALL SHOWER
STAINLESS STEEL
MIRROR
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT
WALL TILE- PWT
LIGHT FIXTURE
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT
LIGATURE-
RESISTANT WALL
SHOWER
WALL TILE- PWT
S.S. LAVATORY W/
PIPE COVER
S.S. TOILET W/
FLUSH VALVEWALL TILE- PWT
HM DOOR &
FRAME- PAINT
BOTH SIDES
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT
WALL TILE- PWT
HM DOOR &
FRAME- PAINT
BOTH SIDES
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT WALL TILE- PWT
HM DOOR &
FRAME- PAINT
BOTH SIDES
WALL TILE- PWT
S.S. LAVATORY W/
PIPE COVER
S.S. TOILET W/
FLUSH VALVE
STAINLESS STEEL
MIRROR
S.S. LAVATORY W/
PIPE COVER
S.S. TOILET W/
FLUSH VALVE
LIGATURE-
RESISTANT
WALL SHOWER
WALL TILE- PWT
LIGHT FIXTURE
LIGHT FIXTURE
WALL TILE- PWTWALL TILE- PWT
WALL TILE- PWT WALL TILE- PWT WALL TILE- PWT
WALL TILE- PWT
WALL TILE- PWT
HM DOOR &
FRAME- PAINT
BOTH SIDES
LIGHT FIXTURE LIGHT FIXTURE
LIGHT FIXTURE LIGHT FIXTURE
S.S. LAVATORY W/
PIPE COVER
S.S. TOILET W/
FLUSH VALVE
WALL MNTD.
HEATER TO
REMAIN - PAINT
WALL MNTD.
HEATER TO
REMAIN - PAINT
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND
CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE
PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2023
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
SCALE:
ENLARGED FLOOR PLAN-AREA A EAST
1/2"=1'-0"
SCALE:
ENLARGED FLOOR PLAN-AREA A EAST
1/2"=1'-0"
SCALE:
ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"
FLOOR TILE - PFT
FLOOR TILE - PFT
FLOOR TILE - PFT
STAINLESS STEEL
MIRROR
WALL TILE- PWT
STAINLESS STEEL
MIRROR
WALL TILE- PWT
WALL TILE- PWT
S.S. LAVATORY W/
PIPE COVER
S.S. TOILET W/
FLUSH VALVE
STAINLESS STEEL
MIRROR
FLOOR DRAIN
FLOOR DRAIN
FLOOR DRAIN
FLOOR DRAIN
FLOOR DRAIN
FLOOR MOUNTED
TOILET
FLOOR MOUNTED
TOILET
FLOOR MOUNTED
TOILET
FLOOR MOUNTED
TOILET
FLOOR MOUNTED
TOILET
A-601
A-601
02A
04A
A-601
A-601
10A
12A
A-601
14A
16A
A-601
11A-601
FLOOR DRAIN
A-601
A-601 18A20A
AutoCAD SHX Text C
ELEV 23
ELEV 24
ELEV 24A
ELEV 21
ELEV 22
ELEV 22A
ELEV 25
ELEV 26
ELEV 28
ELEV 27
ELEV 33
ELEV 34
ELEV 35
ELEV 36
ELEV 36A
ELEV 34A
ELEV 29
ELEV 30
ELEV 32
ELEV 31
SHOWER
SHOWER
SHOWER
SHOWER
LIGATURE-
RESISTANT WALL
SHOWER
WALL TILE- PWT
A-602
RL
TM
TM
INTERIOR
ELEVATIONS &
FLOOR TILE
LAYOUT
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK WALL TILE- PWT
BULLNOSE TILE
HM DOOR &
FRAME- PAINT
BOTH SIDES
SCALE:
SHOWER ROOM 132
1/4"=1'-0"
SCALE:
SHOWER ROOM 133
1/4"=1'-0"
SCALE:
SHOWER ROOM 160
1/4"=1'-0"
SCALE:
SHOWER ROOM 161
1/4"=1'-0"
LIGHT FIXTURE
LIGHT FIXTURE
LIGHT FIXTURE
LIGHT FIXTURE
LIGATURE
RESISTANT WALL
SHOWER
WALL TILE- PWTWALL TILE- PWT
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
HM DOOR &
FRAME- PAINT
BOTH SIDES
HM DOOR &
FRAME- PAINT
BOTH SIDES
HM DOOR &
FRAME- PAINT
BOTH SIDES
STAINLESS STEEL
CO COVER
LIGATURE
RESISTANT WALL
SHOWER
WALL TILE- PWT
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
LIGATURE
RESISTANT WALL
SHOWER
WALL TILE- PWT
WALL TILE- PWT
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
WALL TILE- PWT
WALL TILE- PWT
WALL TILE- PWT
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
WALL TILE- PWT
REFINISH WOOD
BENCH - PAINT
SUPPORTS BLACK
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND
CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE
PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2023
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
WALL TILE- PWT WALL TILE- PWT
WALL TILE- PWT
SCALE:
ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"
SCALE:
ENLARGED FLOOR PLAN-AREA B
1/2"=1'-0"
FLOOR TILE- PFT
FLOOR TILE- PFT
FLOOR DRAIN
FLOOR DRAIN
FLOOR TILE- PFT
A-602
27 A-602
A-602
A-602
34 A-602 36A34A
A-602
22A
24A
AutoCAD SHX Text C
ROOM FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR
N S E W
WALLS
MATL HEIGHT
CEILING
NOTESBASE
AE-141 TOILET / SHOWER ROOM PFT PWT
AE-142
AE-157
AE-158
B-121
B-132
B-133
B-160
STRUC. 8'-0" 1,2,3,4,5,6,7
B-161
SHOWER ROOM
SHOWER ROOM
SHOWER ROOM
SHOWER ROOM
TOILET / SHOWER ROOM
TOILET / SHOWER ROOM
TOILET / SHOWER ROOM
TOILET / SHOWER ROOM
PFT
PFT
PFT
PFT
PFT
PFT
PFT
PFT --
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
STRUC. 8'-0"
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
1,2,3,4,5,6,7
PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
PWT PWT PWT PWT
KEY NOTES
1. SEE REFLECTED CEILING PLAN, FLOOR PLAN AND SECTIONS FOR ADDITIONAL INFORMATION
2.
3.
WHERE WALL TILE IS SPECIFIED PROVIDE OVER CMU
4.
5.
EXPOSED CONCRETE PLANK CEILINGS TO RECEIVE EPOXY PAINT - (1) COAT PRIMER, (2) FINISH COATS
ALL TILE GROUT TO BE EPOXY GROUT.
6. HVAC GRILLES/DIFFUSERS & SPEAKER COVERS TO BE PAINTED TO MATCH CEILING.
WHERE FLOOR TILE IS SPECIFIED PROVIDE OVER CONCRETE
PAINT INTERIOR AND EXTERIOR OF HOLLOW METAL DOOR - EPOXY PAINT - (1) COAT PRIMER, (2) FINISH
COATS)
7.
ROOM FINISH LEGEND
FLOORS
PFT PORCELAIN FLOOR TILE
WALL BASE
NONE
WALLS
PWT PORCELAIN WALL TILE
CEILINGS
STRUC. EXPOSED CONC. PLANK (PAINT)
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
SCALE:A-701
1 ENLARGED FLOOR PLAN - AREA A EAST
1/2"=1'-0"SCALE:A-701
2 ENLARGED FLOOR PLAN - AREA A EAST
1/2"=1'-0"SCALE:A-701
3 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"
SCALE:A-701
4 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"SCALE:A-701
4 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"
LIMIT OF WORK
A-701
RL
TM
TM
ROOM FINISH
SCHEDULE
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.24 ADDENDUM 1
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0" PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
NN
NNN
WALL HUNG BENCH-
PAINT BRACKETS AND
STRIP / REVARNISH
WOOD SEAT
WALL HUNG BENCH-
PAINT BRACKETS AND
STRIP / REVARNISH
WOOD SEAT
WALL HUNG BENCH-
PAINT BRACKETS AND
STRIP / REVARNISH
WOOD SEAT
WALL HUNG BENCH-
PAINT BRACKETS AND
STRIP / REVARNISH
WOOD SEAT
SURFACE MOUNTED
SHOWER UNIT
SURFACE MOUNTED
SHOWER UNIT
SURFACE MNTD.
SHOWER UNIT
SURFACE MOUNTED
SHOWER UNIT
SURFACE MOUNTED
SHOWER UNIT
SURFACE MOUNTED
SHOWER UNIT
SURFACE MNTD.
SHOWER UNIT
SURFACE MNTD.
SHOWER UNIT
STAINLESS STEEL
PLUMBING FIXTURES
STAINLESS STEEL
PLUMBING FIXTURES
STAINLESS STEEL
PLUMBING FIXTURES
STAINLESS STEEL
PLUMBING FIXTURES
STAINLESS STEEL
PLUMBING FIXTURES
SURFACE MOUNTED
SHOWER UNIT
AutoCAD SHX Text
AutoCAD SHX Text
STOR.
SHOWER
SHOWER
SHOWER
SHOWER
PASSAGE
SHOWER
SHOWER
SHOWER
SHOWER
TOILET
SHOWER
121A
RENOVATION KEY NOTES
PROVIDE AND INSTALL CERAMIC FLOOR TILE. (REFER TO FINISH
SCHEDULE)
PROVIDE AND INSTALL CERAMIC WALL TILE. (REFER TO FINISH
SCHEDULE AND INTERIOR ELEVATIONS)
PAINT CEILING AND BOTH SIDES OF THE DOOR. (REFER TO FINISH
SCHEDULE AND INTERIOR ELEVATIONS)
PROVIDE AND INSTALL NEW WATER CLOSETS AND FLUSH VALVES.
PROVIDE AND INSTALL LAVATORIES AND FAUCETS.
PROVIDE AND INSTALL MIRRORS. (REFER TO INTERIOR ELEVATIONS
DWG.)
PROVIDE AND INSTALL SURFACE MOUNTED WALL SHOWER. (REFER
TO INTERIOR ELEVATIONS DWGS.)
REFINISH WOOD BENCHES AND SUPPORTS.
CLEAN AND REINSTALL DRAIN COVERS. PROVIDE AND INSTALL NEW
DRAIN COVERS AS REQUIRED AND APPROVED BY ARCHITECT
PROVIDE AND INSTALL TOGGLE SWITCHES AND STAINLESS STEEL
COVER PLATES.
PROVIDE AND INSTALL LIGHT FIXTURES W/LED LAMPS, 3,500K COLOR
TEMPERATURE THROUGHOUT.
CLEAN AND REINSTALL MECHANICAL GRILLES. REPLACE AS
REQUIRED AND APPROVED BY ARCHITECT.
CLEAN AND REINSTALL SPEAKER GRILLES. REPLACE AS REQUIRED
AND APPROVED BY ARCHITECT.
CLEAN AND REINSTALL SPRINKLER HEAD ESCUTCHEONS. REPLACE
AS REQUIRED AND APPROVED BY ARCHITECT. THE FIRE PROTECTION
SYSTEM SHALL BE INSPECTED AND CERTIFIED BY THE AUTHORITY
HAVING JURISDICTION.
EXISTING FIRE/SMOKE DETECTORS ARE TO REMAIN. CONTRACTOR
TO VERIFY THAT THEY ARE FUNCTIONING PROPERLY.
EXIST. WALL MOUNTED HEATER TO REMAIN. PAINT TO MATCH WALLS.
1. THIS PLAN IS INTENDED TO SHOW GENERAL
COORDINATION OF OVERHEAD WORK.
ALL CEILING HEIGHTS ARE FINISH DIMENSIONS.
2. ALL CEILING PENETRATIONS BY FIRE PROTECTION
HEADS, FIRE ALARM DEVICES, LIGHT FIXTURES,
SPEAKERS, ETC. MUST BE FIRE STOPPED.
3. PROVIDE AND INSTALL FIRE DAMPERS AT DUCT
PENETRATIONS OF ALL FIRE RATED ASSEMBLIES.
CEILING RADIATION DAMPERS ARE REQUIRED AT ALL
DUCT/FAN PENETRATIONS OF THE FIRE RATED
CEILINGS.
4. REFER TO SPECIFICATIONS MANUAL FOR ADDITIONAL
INFORMATION.
GENERAL CEILING NOTES
CEILING SCHEDULE
MARK DESCRIPTION REMARKS
PLANK CONCRETE PLANK EPOXY PAINT- PRIMER +(2) COATS
REFLECTED CEILING PLAN LEGEND
FINISHED CEILING MATERIAL/ ELEVATION
WALL MOUNTED LIGHT FIXTURE
XXX #'-##"
MECHANICAL DIFFUSER- EXHAUST
SPEAKER GRILLE
CEILING MOUNTED LIGHT FIXTURE
FIRE SPRINKLER HEAD
FIRE/SMOKE DETECTOR
SCALE:A-101
1 ENLARGED FLOOR PLAN - AREA A EAST
1/2"=1'-0"SCALE:A-101
2 ENLARGED FLOOR PLAN - AREA A EAST
1/2"=1'-0"SCALE:A-101
3 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"
SCALE:A-101
4 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"SCALE:A-101
4 ENLARGED FLOOR PLAN - AREA B
1/2"=1'-0"
LIMIT OF WORK
A-801
RL
TM
TM
REFLECTED
CEILING PLANS
12.13.23 90% REVIEW
1.8.24 BIDDING/PERMITS
2.8.23 ADDENDUM 1
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0" PLANK 8'-0"
PLANK 8'-0"
PLANK 8'-0"
11 11
1 14
14 14
1 2
1 2
1 2
1 2
1 2
1 2
1 2
1 2
'A'
'A'
'A'
'A'
'A'
'A'
'B'
'A'
'A'
NN
NNN
'B'
ACCESS PANEL - PAINT
TO MATCH CEILING
11'B'
11'B' 11'B' 11'B'
11'B'
'B'
'B'
'B'
Sheet Number:
Project Number:
Sheet Title:
Drawn:
Checked:
Approved:
Seal:
45650 Grand River Avenue Novi, Michigan 48374
Ph: (248)349-4500 • Fax: (248)349-1429
Issued ForDate
THIS MATERIAL IS THE EXCLUSIVE PROPERTY OF SIDOCK GROUP, INC. AND
CANNOT BE REPRODUCED, COPIED, OR USED IN ANY MANNER WITHOUT THE
PRIOR WRITTEN CONSENT OF SIDOCK GROUP, INC. 2023
Project:
Client:
Corporate Headquarters
Key Plan:
www.sidockgroup.com
Sidock Group
No Scale
ARCHITECTSENGINEERS CONSULTANTS
757 S. Wisconsin Ave.
Gaylord, Michigan 49735
Ph: (989)705-8400 • Fax: (989)705-8403
Gaylord Office
Okemos • Gaylord • Sault Ste. Marie Novi • Wyandotte • Muskegon
Tampa, FA • Williamsport, PA
DEPARTMENT OF
HEALTH & HUMAN
SERVICES
FILE NO. 491/23073
SHAWONO CENTER
UPGRADE YOUTH
BATHROOMS/
SHOWERS
10 N. HOWES LAKE ROAD
GRAYLING, MICHGAN 49738
523191
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DC Spec Revisions Affec ve 2/14/24
Add 00100:
26. PREVAILING WAGE: The Bidding Documents include either the a ached Appendix V of prevailing rates of wages and fringe benefits for all classes of Construc on Mechanics called for in the Bid and resul ng Contract, if any, or the a ached current prevailing wage determina on issued by the U.S.
Department of Labor, as applicable depending on the funding source(s).
Replace 00700-2.5 with:
2.5 Prevailing Wages and Access to Payroll Records:
2.5.1 Prevailing Wages:
To the extent applicable, Contractor will comply with federal and state (2023 PA 10, MCL 408.1101 to 408.1126) prevailing wage requirements.
Federal Prevailing Wages -The federal prevailing wage requirements in the a ached Federal Provisions Addendum apply when the Davis-Bacon Act (40 USC 3141-3148) as supplemented by Department of Labor regula ons (29 CFR Part 5, “Labor Standards Provisions Applicable to Contracts Covering Federally Financed and Assisted Construc on”) applies.
State Prevailing Wages-The following provisions of this Ar cle 7.15 apply when 2023 PA 10 applies.
Prevailing Wage and Fringe Benefits--The rates of wages and fringe benefits to be paid to each class of Construc on Mechanic by DB En ty and Subcontractors, shall not be less than the wage rates and fringe benefit rates prevailing in the locality in which the work is performed.
Nondiscrimina on, Nonretalia on- Contractor or a Subcontractor shall not discharge, discipline, retaliate against, or otherwise discriminate against a Construc on Mechanic, or threaten to do any of these things, because the Construc on Mechanic reported or was about to report a viola on or suspected viola on of the act.
Construc on Mechanics under this Contract are intended beneficiaries of the contractual prevailing wage, fringe benefit, and nondiscrimina on nonretalia on requirements of the Contract. Any such Construc on Mechanic aggrieved by failure of a contractor or subcontractor to pay prevailing wages or benefits as specified in the Contract, or by viola on of sec on 7 of 2023 PA 10, in addi on to any other remedies provided by law, may bring an ac on in a court of competent jurisdic on against such contractor or subcontractor for damages or injunc ve relief and may be awarded reinstatement or other appropriate relief, and all damages sustained, together with actual costs and a orney fees at trial and on appeal.
Contractor and Subcontractors shall keep posted on the construc on site, in a conspicuous place, a copy of all prevailing wage and fringe benefit rates prescribed in this Contract and shall keep an accurate record showing the name and occupa on of and the actual wages and benefits paid to each Construc on Mechanic employed by it in connec on with the Contract. This record shall be available for reasonable inspec on by the State.
2.5.2 Payroll: The Contractor and its Subcontractors must maintain and keep, in accordance with generally accepted accoun ng principles, records pertaining to the bidding, award and performance of the Work, including, but not limited to cer fied payroll, employment records and all data used in es ma ng the Contractor’s prices for the Bid, Change Order, proposal or claim. The Owner or its representa ve must have access to those records, must have the right to interview the Contractor’s employees and must be provided with appropriate facili es for the purpose of inspec on, audit/review and copying for five years a er final payment, termina on, or date of final resolu on of any dispute, li ga on, audit excep on or appeal. The payroll and other employment records of workers assigned to the site must contain the name and address of each worker, correct wage classifica on, rate of pay, daily and weekly number of hours worked, deduc on made, and actual wages paid. The Contractor must maintain records that show: (a) the an cipated costs or actual costs incurred in providing such benefits, (b) that commitment to provide such benefits is enforceable, and (c) that the plan or program is financially responsible and has been communicated in wri ng to the workers affected.
Delete 00800 STATE-FUNDED PROJECT PREVAILING WAGE REQUIREMENTS #1 & #2.
| draft add 1.pdf |
| Addendum 1.pdf |
| Addendum 1_Shawono Showers DRAWINGS |
| 523191_CS-000 |
| Sheets and Views |
| CS-000 |
| 523191_CS001 |
| Sheets and Views |
| CS001 |
| 523191_AD101 |
| Sheets and Views |
| AD101 |
| 523191_A111 |
| Sheets and Views |
| A111 |
| 523191_A601 |
| Sheets and Views |
| A601 |
| 523191_A602 |
| Sheets and Views |
| A602 |
| 523191_A701 |
| Sheets and Views |
| A701 |
| 523191_A801 |
| Sheets and Views |
| A801 |
DC Spec Revisions Effective 2.14.24
File details come from the government source that posted it. Updated .