CON26-0006_Attachment_3_04.21.25_Utility_Submittal__11891.pdf
PDF 1 MB Posted
- Attached to
- EXT REC | CON26-0006 Precita Park - MLBE
- Solicitation number
- SFGOV-0000010933
- Issued by
- San Francisco County, San Francisco City, California
About this file
This is a utility submittal document for a restroom building project at Precita Park in San Francisco, California, submitted by The Public Restroom Company to the City of San Francisco on April 21, 2025. The submittal includes design drawings, utility location plans, and specifications necessary to complete final construction drawings and prepare for building installation at the site. The document requests completion of a Utility Location Plan identifying the points of connection (P.O.C.) for sewer, water, and electrical services, with all P.O.C. locations required to be positioned 4 to 6 feet from the building slab edge. The City of San Francisco contact is Eoanna Goodwin (628-652-6645), and the document has been marked as approved by the City. The submittal includes detailed specifications for water supply (1.5-inch copper type K service line, 46 to 60 psi required pressure), electrical service (40 amps, 2-phase, 1.5-inch galvanized rigid steel conduit at 18 inches minimum depth), and sewer service (4-inch VCP ASTM C-700 extra strength pipe at 18 inches depth).
The utility information provided in the completed submittal is essential for maintaining the project timeline for delivery of the modular restroom building. The City has provided specific utility details including electrical service specifications (40A/2Phase), water meter size (1.5 inches), water pressure (90 psi), sewer specifications (4-inch VCP at 18 inches depth), and material requirements. This submittal supports the broader Precita Park improvements project, which is a Micro LBE Set-Aside solicitation with an Engineer's Estimate of $200,000, a pre-bid meeting held on July 24, 2025, and bids due by August 7, 2025 at 2:30 p.m.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RESTROOM UTILITY SUBMITTAL
April 21, 2025 Precita Park
San Francisco, CA
OWNER
City of San Francisco, CA 49 South Van Ness Ave, Suite 1220 San Francisco, CA 94103 Contact: Eoanna Goodwin Phone: 628-652-6645
THE PUBLIC RESTROOM COMPANY
CUSTOMER APPROVAL
APPROVED
APPROVED EXCEPT AS NOTED
REVISE AS NOTED AND RESUBMIT
APPROVED by _____________Date _______
Letter of Transmittal
To: Eoann Goodwin Re: Precita Park – San Francisco, CA
49 South Van Ness Ave, Ste 1220 San Francisco, CA 94103 Date: April 21, 2025
Please find enclosed:
Design Drawings X Cover Letter Change Order Plans X Utility Location Plan Samples
Specifications Bid Plan Pages Color Charts
Color Selection Schedule Other:
Qty Description 1 Cover Letter 1 Utility Plan to be completed
Please contact us if you have any questions.
Mike Meglen – Project Coordinator For – Steve Myler – Regional Sales Manager Phone: (888) 888-2060 Fax: (888) 888-1448 meglen@publicrestroomcompany.com SteveM@publicrestroomcompany.com mailto:meglen@publicrestroomcompany.com mailto:SteveM@publicrestroomcompany.com
April 21, 2025
Eoanna Goodwin
49 South Van Ness Ave, Suite 1220 San Francisco, CA 94103
RE: POC Utilities Submittal for Precita Park Restroom
Dear Eoanna Goodwin, Enclosed please find our POC Utility Locations Submittal for your completion and approval.
This information is needed to complete the final construction drawings and prepare for the building set at the site. Answers to this submittal will also enable us to maintain our timeline for delivery of this project.
The information requested is to obtain the utility point of contact locations and other utility details. Please complete the Utility Location Plan for the building with the requested information, sign, date, and return your approval. Again, this information is vital for our preparation of the building set at the site.
Thank you for your prompt attention to this request.
Respectfully, Mike Meglen – Project Coordinator For – Steve Myler – Regional Sales Manager Phone: (888) 888-2060 Fax: (888) 888-1448 meglen@publicrestroomcompany.com SteveM@publicrestroomcompany.com mailto:meglen@publicrestroomcompany.com mailto:SteveM@publicrestroomcompany.com
LOCATION OF UTILITY
P.O.C. TO BE 4' MIN. 6' MAX
FROM BUILDING SLAB EDGE
4'- 0"
MI
N.6'-
0"
MA
X
RESTROOM BUILDING - OPTION 'B' 11891
DRAWN BY:C O P Y R I G H T 2 0 2 5 , P U B L I C R E S T R O O M
COMPANY THIS MATERIAL IS THE EXCLUSIVE
PROPERTY OF PUBLIC RESTROOM COMPANY
AND SHALL NOT BE REPRODUCED, USED, OR
D I S C L O S E D T O O T H E R S E X C E P T A S
AUTHORIZED BY THE WRITTEN PERMISSION
O F P U B L I C R E S T R O O M C O M P A N Y .
PROJECT:
BUILDING TYPE: DATE:
PROJECT #:
SHEET:
~NOT FOR CONSTRUCTION ~ PRELIMINARY DESIGN DRAWING ONLY ~ DO NOT SCALE, DIMENSIONS PRESIDE
PRECITA PARK
SAN FRANCISCO, CA
03/20/2025
JAG
Building Better Places To Go.
Ph: 888-888-2060 Fax: 888-888-1448
CONCRETE UTILITY GROUND
BOX MARKED "ELECTRIC"
(BY OTHERS)
FINAL LOCATION "TBD"
E
CONCRETE UTILITY GROUND
BOX MARKED "WATER"
(BY OTHERS)
FINAL LOCATION "TBD"
W
UTILITY LOCATION & BUILDING ORIENTATION PLAN
N
CONCRETE UTILITY GROUND
BOX MARKED "SEWER"
(BY OTHERS)
FINAL LOCATION "TBD"
S
UTILITY
1. INDICATE NORTH ON THE COMPASS AS IT RELATES TO THE ORIENTATION OF
THE BUILDING FLOOR PLAN SHOWN.
2. INDICATE ON FLOOR PLAN THE SEWER, WATER, AND ELECTRICAL POINT OF
CONNECTION (P.O.C.). LOCATION TO BE 4' MIN. 6' MAX. FROM SLAB EDGE.
4. WATER SERVICE:
4.1. METER SIZE:
4.2. SIZE TO P.O.C.:
4.3. PRESSURE AT METER AND OR P.O.C.
(INDICATE WHICH):
4.4. DISTANCE FROM METER TO P.O.C.:
4.5. ELEVATION DIFFERENCE FROM METER TO P.O.C.:
4.6. P.O.C. DEPTH:
4.7. MATERIAL:
4.8. COMMENTS:
5. SEWER SERVICE:
5.1. SIZE:
5.2. DEPTH:
5.3. MATERIAL:
5.4. COMMENTS:
3. ELECTRICAL SERVICE:
3.1. CONDUIT SIZE:
3.3. DEPTH:
3.4. MATERIAL:
3.5. COMMENTS:
APPROVED BY:
DATE:
BUILDING WATER SUPPLY DETAILS:
1. FIXTURE UNITS: 46.75 (CPC-UPC)
2. BUILDING DEVELOPED LENGTH (TO P.O.C. 6' MAX. FROM BLDG.): 27'-11"
3. REQUIRED PRESSURE: 46 to 60 psi
4. HIGHEST FIXTURE OR OUTLET ABOVE FINISH FLOOR: 4'
5. SUPPLY FROM SITE P.O.C. TO BUILDING: 1 1/2"
THE FOLLOWING TO BE COMPLETED BY CLIENT:
(Please Sign & Print)
3.2. SERVICE SIZE (VOLTAGE/AMP/PHASE):
NOTE: LOCATE UTILITY P.O.C. LOCATIONS ON FLOOR PLAN.
LOCATION TO BE 4' MIN. 6' MAX. FROM SLAB EDGE.
eoanna.Goodwin Snapshot eoanna.Goodwin Snapshot eoanna.Goodwin Snapshot eoanna.Goodwin Text Box 1.5" eoanna.Goodwin Text Box
40 A/ 2PHASE
eoanna.Goodwin Text Box
18" MIN
eoanna.Goodwin Text Box
GALVANIZED RIGID STEEL
eoanna.Goodwin Text Box 2" eoanna.Goodwin Text Box 1 1/2" eoanna.Goodwin Text Box
90 PSI
eoanna.Goodwin Text Box
20', VIF
eoanna.Goodwin Text Box eoanna.Goodwin Text Box
SAME
eoanna.Goodwin Text Box
COPPER TYPE K
eoanna.Goodwin Text Box 4" eoanna.Goodwin Text Box
18", VIF
eoanna.Goodwin Text Box
VCP ASTM C-700 EXTRA STRENGTH PIPE
| CONDUIT SIZE: |
| ELECTRICAL SIZE (VOLTAGE/AMP): |
| ELECTRICAL DEPTH: |
| ELECTRICAL MATERIAL: |
| ELECTRICAL COMMENTS: |
| WATER METER SIZE: |
| WATER P: |
| O: |
| C: |
| SIZE: |
| WATER PRESSURE AT METER AND/OR P: |
| O: |
| C: |
| DISTANCE FROM WATER METER TO P: |
| O: |
| C: |
| ELEVATION DIFFERENCE FROM METER TO P: |
| O: |
| C: |
| P: |
| O: |
| C: |
| DEPTH: |
| MATERIAL: |
| COMMENTS: |
| SEWER SIZE: |
| SEWER DEPTH: |
| SEWER MATERIAL: |
| SEWER COMMENTS: |
| DATE: |